This is a Project Specification document from the Department of Homeland Security, United States Coast Guard for a roof repair project at Sector New Orleans. The project involves repairing the 4th Deck Roof, with specific scope of work including removing and replacing sealants at EIFS coping joints and metal flashing, installing new backer rods, applying polyurethane sealant according to manufacturer instructions, and applying a new base coat and top colored coat to the entire EIFS coping. The project site is located at 200 Hendee St, New Orleans, LA 70114. Contractors are required to follow OSHA Safety and Health Standards and will be responsible for disposing of old materials. Site visit contacts are CWO James Potts and DC1 Jacob Burns, with their respective contact information provided.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF HOMELAND SECURITY

UNITED STATES COAST GUARD

Sector New Orleans, LA

Project Specification

For

Sector New Orleans Roof Repair

Table of Contents

DIVISION 01 – GENERAL REQUIREMENTS 3

SECTION 01 11 00 - GENERAL PARAGRAPHS

PART 1 GENERAL

DIVISION 01 – GENERAL REQUIREMENTS

SECTION 01 11 00 - GENERAL PARAGRAPHS

1.1 PROJECT BRIEF: Overall deterioration of EIFS including sealant, roof of 4th Deck.

1.2 SCOPE OF WORK: This work will take place on the 4th Deck Roof at Sector Nola.

1. Remove existing sealants at all EIFS coping joints.

2. Clean and prepare all surfaces at all joints for application of new polyurethane sealant.

3. Supply and install new backer rods to all joints.

4. Apply new polyurethane sealant to all joints IAW manufactures instructions.

5. Remove existing sealant at metal flashing and EIFS transition.

6. Clean and prepare all surfaces at metal flashing and EIFS transition.

7. Apply new polyurethane sealant to all joints IAW manufactures instructions.

8. Apply mesh, base coat and top colored coat to entire EIFS coping.

9. Remove and discard all debris and materials from the site upon completion.

1.3 LOCATION: Project site is located at 200 Hendee St, New Orleans, LA 70114.

1.4 POST AWARD: N/A

1.5 CONTINUITY OF FACILITIES OPERATION: N/A

1.6 NOTICE TO PROCEED (NTP) Notice to Proceed (NTP) begins the Project Award. N/A

1.7 NOTIFICATION OF START AND COMPLETION OF WORK: N/A

1.8 RECYCLING AND DISPOSAL OF REFUSE: Disposal of the old Polyurethane Sealant and Backer Rods will be the responsibility of the contractor.

1.9 SAFETY: During the execution of this contract, the Contractor shall conform to the rules and regulations as set forth by OSHA Safety and Health Standards, 29 CFR Part 1926 - Safety and Health Regulations for Construction. The contractor shall provide barriers, temporary fencing, trench covers, fall protection, etc. wherever work could cause injury to workers, visitors, Coast Guard personnel, or dependents.

1.10 TEMPORARY FACILITIES:

A. N/A

1.11 PROJECT SCHEDULE: N/A

1.12 DRAWINGS: N/A

PART 2 PRODUCTS – IAW EIF Manufacturer’s Instructions.

PART 3 CONTACTS FOR SITE VISITS:

Name: CWO James Potts

Email: James.M.Potts@uscg.mil

Phone: (504) 846-6146

Name: DC1 Jacob Burns

Email: Jacob.W.Burns@uscg.mil

Phone: (571) 610-4006

END OF SECTION