Section_J_-_Att_No__01_SOWdocx.pdf

PDF 90 KB Posted

Attached to
DX PLUMBING REPAIRS FOR SANTA MONICA NATIONAL RECR
Solicitation number
140P8623Q0093
Issued by

About this file

This statement of work outlines requirements for replacing plumbing at two units of the Diamond X Ranch House located in Calabasas, California. The scope of work involves replacing approximately 90 feet of 4-inch cast iron drain lines under one unit with 4-inch ABS plastic pipe, replacing 90 feet of 2-inch horizontal drain lines under the other unit in concrete slab with 3-inch ABS plastic or equivalent material, and reconnecting all existing vertical drain lines. The contractor must submit a site-specific safety plan and complete all work in accordance with federal, state, and local building codes within 60 days of award. The related federal contract opportunity is solicitation number 140P8623Q0093 from the Department of the Interior National Park Service Pacific West Region for DX Plumbing Repairs for Santa Monica National Recreation Area.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAMO – DX Plumbing

Statement of Work (SOW)

Part 1: General Information

A. Introduction

The purpose of this SOW is to perform the replacing of plumbing on two units at the

Diamond X (DX) Ranch House location.

B. Background

The Diamond X Ranch is located at 26412 Mulholland Highway, Calabasas, CA 91302. This building is a 2986 sf wooden frame and stucco non-historic structure built in 1964 with a large wooden deck surrounding 2 sides of the building. This main building #901 with 2 baths has a large under floor crawl space where plumbing is located. The one-bathroom unit will require concrete breaking as piping is in slab unless newer technology used.

Scope

The contractor shall provide all necessary personnel, equipment, tools, materials, training, supervision and other items necessary to replace existing pipes or fittings at the Diamond X

Ranch. Contractor shall submit a site-specific safety plan before work commences to the

Contracting Officer (CO) for approval.

The overall project purpose is to replace the sewer plumping at said locations with ABS material

The DX Ranch House (Duplex) was determined to need the sewer plumbing replaced based on age and condition of existing plumbing. Including the following tasks:

On the 2 Bathroom side of duplex, perform sewer drain re-pipe (In open crawl space):

• Replace all horizontal Cast Iron pipe drain lines under duplex home and replace with

ABS plastic pipe.

• 90’ of 4” cast iron needs replacing under house, replace with 4” ABS pipe. Plus, an additional 20’ x 4” run connecting to septic from perimeter of house, (septic tank is outdoors).

• Leave all vertical drain lines and tie into existing verticals; 1 kitchen sink drain, 2 toilets with closet flanges, 1 lav. sink drain, 2 into 1 lav. sink drain, and 1 shower drain.

• Discard any construction debris in appropriate receptacles.

On the 1 Bathroom one kitchen, one laundry room drain re-pipe is in slab:

• Replace 90’ x 2” horizontal drain\sewer line under home in slab and replace with 3”

ABS plastic or equivalent material, may use newer technology.

• Re-connect new drain line to all existing verticals.; 1 toilet with closet flange, 1 lav.

Sink drain, 1 shower/bathtub drain in kitchen one sink drain and in laundry room one washing machine drain.

• Break\Demo and patch concrete (unless newer technology used).

• If proposed replacement method requires cutting concrete slab include in price demo and patching of concrete.

• Discard any construction debris in appropriate receptables.

Part 2: Work Requirements

A. Technical Requirements

All work shall be completed in accordance with current Federal and State Building Codes.

The contractor will be responsible for removing and disposing of any debris generated during the workday.

The contractor shall immediately notify the Contracting Officer of any ambiguities, inconsistencies, and errors discovered in this specification.

The contractor shall provide to the Contracting Officer a list of all Sub-Contractors, if any, prior to the commencement of work.

All work will be performed Monday through Friday, no earlier than 8:00 a.m. and no later than 5:00 p.m.

Contractor shall take every precaution to prevent damage to government and personal property and vegetation at the sites. Should any damage result, the contractor shall complete repairs or replacement to the satisfaction of the COR, at no cost to the government.

Storage of materials and equipment shall be limited to areas designated by the COR during contractor’s operations. The contractor is responsible for daily clean-up and disposal.

The buildings will be occupied during the performance period of this contract. Always provide and maintain adequate egress, in accordance with the Life Safety Code (NEPA 101).

No corridor, aisle, stairway, door, or exist shall be obstructed or used in a manner that interferes with egress.

B. Deliverables

The contractor shall provide a written schedule within 5 days after award, and a site specific safety plan prior to commencement of work. The contractor shall complete work within 60 days of award.

Part 3: Supporting Information

A. Security

Contractor shall take all precautions to protect the public and all property during performance under this contract. The contractor will ensure buildings are always secure.

The contractor shall coordinate work schedules and locations with the Contracting Officer’s

Representative (COR) and shall erect barricades and appropriate signs while working to prevent harm to persons and property.

The contractor shall be responsible for maintaining an effective accident prevention program and providing a safe environment for all personnel and visitors. The contractor shall ensure that work is accomplished in compliance with Federal, State and local safety and health requirements. The contractor shall comply with all OSHA requirements.

B. Place of Performance

26412 Mulholland Highway

Calabasas, CA 91302

C. Special Considerations

No NPS equipment will be provided.

File details come from the government source that posted it. Updated .