Section_2556_-_Water_Distribution_System.pdf

PDF 412 KB Posted

Attached to
CDBG-DR Oakfield Palafox Stormwater Upgrades - HS005
Solicitation number
PD 25-26.099
Issued by
Escambia County, Florida

About this file

This file is Section 2556 of the Escambia County Utilities Authority (ECUA) Engineering Manual, providing comprehensive technical specifications for water distribution system construction and materials. The specifications establish standards for the furnishing and installation of all pipes, fittings, structures, and accessories required for water transmission, distribution, and service lines. The document references applicable standards from the American Water Works Association (AWWA), American Society for Testing and Materials (ASTM), American National Standards Institute (ANSI), and American Society of Mechanical Engineers (ASME), and mandates that all materials be new, suitable for potable water use, and rated for a minimum pressure of 160 psi. Water main pipe materials permitted include Polyvinyl Chloride (PVC), Ductile Iron Pipe (DIP), and High-Density Polyethylene (HDPE) in sizes ranging from 4 inches through 63 inches, with specific requirements for cement-mortar lining, epoxy exterior coating for DIP, and color-coding requirements. Water service lines are limited to sizes up to 2 inches and must be constructed using either Polyethylene tubing or copper water service tubing, installed as one continuous piece with no intermediate couplings. All appurtenances, including resilient seated gate valves, butterfly valves, fire hydrants, flushing hydrants, and backflow prevention assemblies, must be manufactured in accordance with current AWWA standards and NSF-approved for potable water use.

Installation procedures mandate trench excavation and pipe preparation in accordance with ECUA standards, with pipe installed to line and grade as indicated on construction plans and manufacturer recommendations. Valves and appurtenances must be installed with mechanical joint restraints and thrust blocks for all 90-degree bends, 45-degree bends, tees, tapping sleeves, dead-ends, and hydrants. Tracer wire must be installed on all new water mains and service lines for locating purposes, with color-coded piping required throughout. All newly installed water lines are subject to flushing, pressure and leakage testing at 150 psi minimum for one hour, with acceptable leakage determined by specified formulas based on pipe length, diameter, number of joints, and test pressure. Disinfection must be performed using the continuous feed method per AWWA C651 standard, achieving an initial chlorine concentration of 25 mg/l with a minimum 10 mg/l residual after 24 hours, followed by bacteriological sampling. Two satisfactory bacterial sample sets taken 24 hours apart must meet state requirements before placing the main into service. Measurements and payment are based on lineal feet for water mains, unit basis for appurtenances and fittings, and complete installed assemblies for hydrants, with all incidental costs including joint restraints, couplings, and tracer wire included in the unit price of installed pipe.

View the file

Other files

File Type Posted
CDBG-DR_Oakfield_Palafox_Stormwater_Upgrades_-_HS005_(Addendum_#3_Revision).pdf PDF
Section_4000_-_As-Built_and_Record_Drawing_Requirements.pdf PDF
Section_2651_-_Television_Inspection.pdf PDF
Section_2576_-_Wastewater_Forcemain_Systems.pdf PDF
Section_2570_-_Gravity_Sewer_Collection_Systems.pdf PDF
Section_2556_-_Water_Distribution_System.pdf PDF
Section_2310_-_Jack_and_Bore.pdf PDF
Section_2300_-_Horizontal_Directional_Drilling_(HDD).pdf PDF
Section_2221_-_Utility_Trench_Excavation.pdf PDF
TOC.pdf PDF
Oakfield_Palafox_Phase_III_-_Released_for_Bidding_Planset_-_07-27-2026.pdf PDF
CDBG-DR_Oakfield_Palafox_Stormwater_Upgrades_-_HS005_(Addendum_#1_Revision).pdf PDF
Heavy_Construction_Wage_Determination_5.18.26.pdf PDF
Oakfield_Palafox_-_Phase_3_-_Released_for_Bidding_-_Planset_07-10-2026.pdf PDF
10116-2023232_Oakfield-Palafox_Roadway_and_Drainage_Improvements_Project_-_NOVA_GEOTECHNICAL_ENGINEERING_REPORT_S&S.pdf PDF
HS005-A1_Executed_(6).pdf PDF
HS005_Escambia_County_Regional_Stormwater_Hurricane_Sally_Infrastructure_Repair_Agreement.pdf PDF
NWFWMD_1374115_Permit.pdf PDF
Specification_References.pdf PDF
Exhibit.FederalContractProvisions.HUD_with_signature_5.6.26.pdf PDF
Section-3-project-implementation-plan-template---forms-0-8.pdf PDF
Escambia_County_Section_3_Business_Application_CDBG-DR.pdf PDF
Escambia_County_Section_3_Contract_Clause_CDBG-DR.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Engineering Manual

2025 Edition Section 2556 – Water Distribution Systems Page 1 of 32

Section 2556

Water Distribution Systems

PART 1: General

1.1 General Description of Work – The Contractor shall furnish and install all pipes, fittings, structures and accessories required for water transmission, distribution and/or service lines in accordance with the requirements of the Construction Plans and related Contract Documents.

1.2 Commonly Used Acronyms –

ANSI American National Standards Institute

ASME American Society of Mechanical Engineers

ASSE American Society of Safety Engineers

ASTM American Society for Testing and Materials

AWWA American Water Works Association

CA Concrete Asbestos

CI Cast Iron

DI Ductile Iron

DIPS Ductile Iron Pipe Standard

ECUA Emerald Coast Utilities Authority

FAC Florida Administrative Code

FDEP Florida Department of Environmental Protection

FLG Flange

HDPE High-Density Polyethylene

MJ Mechanical Joint

MSS Manufacturer's Standardization Society

NSF National Standards Foundation

OD Outside Diameter

PVC Polyvinyl Chloride

SBR Styrene Butadiene Rubber

SF Suction Flange

2025 Edition Section 2556 – Water Distribution Systems Page 2 of 32

1.3 Quality Assurance –

1.3.1 AWWA Standards – Construction materials and methods shall comply with the requirements of the latest published edition of American Water Works Association

(AWWA) Standards. Applicable standards include, but may not be limited to, the following:

AWWA C104 Cement Mortar Lining for Ductile Iron Pipe and Fittings

AWWA C105 Polyethylene Encasement for Ductile-Iron Pipe Systems

AWWA C110 Ductile-Iron and Gray-Iron Fittings

AWWA C111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings

AWWA C151 Ductile Iron Pipe, Centrifugally Cast

AWWA C153 Ductile Iron Compact Fittings, For Water Service

AWWA C213

Fusion-Bonded Epoxy Coating for the Interior and Exterior of Steel Water Pipelines

AWWA C301 Prestressed Concrete Cylinder Pressure Pipe (PCCP), 16-in. and Larger

AWWA C502 Dry Barrel Fire Hydrants

AWWA C504 Rubber Seated Butterfly Valves 3-in. through 72-in.

AWWA C509 Resilient Seated Gate Valves For Water Supply Service

AWWA C510 Double Check Valve Backflow Prevention Assembly

AWWA C511 Reduced-Pressure Principle Backflow Prevention Assembly

AWWA C515 Reduced-Wall, Resilient Seated Gate Valves For Water Supply Service

AWWA C550 Protective Interior Coatings for Valves and Hydrants

AWWA C600 Installation of Ductile Iron Water Mains & Their Appurtenances

AWWA C605

Underground Installation of Polyvinyl Chloride (PVC) And Molecularly Oriented Polyvinyl Chloride (PVCO) Pressure Pipe and Fittings

AWWA C651 Disinfecting Water Mains

AWWA C800 Underground Service Line Valves and Fittings

AWWA C900

PVC Pipe And Fabricated Fittings, 4-in. Through 12-in., For Water Transmission And Distribution

AWWA C901

Polyethylene (PE) Pressure Pipe and Tubing 1/2-in. through 3-in., For Water Service

AWWA C905

Polyvinyl Chloride (PVC) Pressure Pipe & Fabricated Fittings, 14-in. through 48-in.

AWWA C906

Polyethylene (PE) Pressure Pipe & Fittings, 4-in. through 63-in. for Water Distribution And Transmission

2025 Edition Section 2556 – Water Distribution Systems Page 3 of 32

1.3.2 ASTM and NSF Standards – In addition, construction materials and methods shall also comply with the requirements of the latest published editions of the American Society for

Testing and Materials (ASTM) Standards, and the National Sanitation Foundation (NSF)

Standard 61.

ASTM A126

Standard Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fittings

ASTM A48 Standard Specification for Gray Iron Castings

ASTM B584

Standard Specification for Copper Allow Sand Castings for General Applications

ASTM B62 Standard Specification for Composition Bronze or Ounce Metal Castings

ASTM B88 Standard Specification for Seamless Copper Water Tube

ASTM D1248

Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable

ASTM D1598

Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure

ASTM D1599

Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

ASTM D1693

Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics

ASTM D2241

Standard Specification for Poly (Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)

ASTM D2737 Standard Specification for Polyethylene (PE) Plastic Tubing

ASTM D3350 Standard Specification for Polyethylene Plastics Pipe and Fittings Materials

ASTM D429 Standard Test Methods for Rubber Property-Adhesion to Rigid Substrates

ASTM F477

Standards Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe

1.3.3 ASME and ANSI Standards – In addition, construction materials and methods shall also comply with the requirements of the latest published editions of the American Society of

Mechanical Engineers (ASME) Standards, and the American National Standards Institute

(ANSI).

ASME/ANSI

B16.20

Metallic Gaskets for Pipe Flanges: Ring-Joint, Spiral-Wound, and Jacketed

ASME/ANSI

B16.1

Gray Iron Pipe Flanges and Flanged Fittings: Classes 25, 125, and 250

ASME/ANSI

B 1.1

Unified Inch Screw Threads, UN and UNR Thread Form

ASME/ANSI

B 1.20.1

Pipe Threads, General Purpose (Inch)

ASME/ANSI

B 1.20.3

Dryseal Pipe Threads (Inch)

2025 Edition Section 2556 – Water Distribution Systems Page 4 of 32

PART 2: Materials and Equipment

2.1 General – All pipe, fittings and accessories shall be new, and shall be suitable and rated for potable water use. All pipe, fittings and accessories shall be rated for a pressure of 160 psi or greater. All water pipe and fittings shall be color coded blue in accordance with FDEP and AWWA requirements, and FAC 62-555.320.

2.2 Delivery, Storage, and Handling – Certificates of Compliance with the Specifications may be required for all materials used on the Project. All materials are to be transported, stored, handled, and installed in accordance with the Manufacturer’s recommendations to avoid physical damage.

All materials shall be stored to prevent physical deterioration due to sun and weather. The ECUA reserves the right to reject material which in any way does not meet the requirements of these

Specifications.

2.3 Water Mains –

2.3.1 Polyvinyl Chloride Pipe (PVC) – PVC pipe shall meet the designations of the “ECUA Pipe

Material Chart”. PVC pipe shall be provided with push-on joints with the bell integrally cast into the pipe. PVC pipe shall be installed with elastomeric gaskets meeting ASTM

Standard F477.

2.3.1.1 Markings – PVC pipe shall be marked to indicate the following:

2.3.1.1.1 Nominal pipe size and OD base

2.3.1.1.2 Material Code Designation

2.3.1.1.3 Dimension Ratio

2.3.1.1.4 Pressure Class or Pressure Rating

2.3.1.1.5 Manufacturer’s Name or Trademark

2.3.1.1.6 National Sanitation Foundation Approved Marking

2.3.1.1.7 Appropriate AWWA or ASTM Standard Number

2.3.1.1.8 Date Pipe Was Manufactured

2.3.2 Ductile Iron Pipe (DIP) – Ductile iron pipe shall meet the designations of the “ECUA Pipe

Material Chart” for design operating pressures of up to 150 psi, installed in Class 2

Trenching conditions. Increase pressure class or bedding class as required by AWWA

C151 for surface loads greater than indicated or operating pressures greater than 150 psi.

DIP shall be constructed with push-on joints using rubber gaskets in accordance with

AWWA Standard C111. Other methods of joint construction, such as mechanical, flanged, or ball-and-socket, may be required in special applications as appropriate. DIP shall be cement-mortar lined in accordance with AWWA Standard C104, unless otherwise specified and approved.

2.3.2.1 Markings – Each ductile iron pipe section shall be marked to indicate the following:

2025 Edition Section 2556 – Water Distribution Systems Page 5 of 32

2.3.2.1.1 Weight class or nominal thickness

2.3.2.1.2 Casting period

2.3.2.1.3 The Manufacturer’s mark

2.3.2.1.4 Country where cast

2.3.2.1.5 Year in which the pipe was produced

2.3.2.2 Lettering – Letters DI or DUCTILE shall be cast or stamped on the pipe. All required markings shall be clear and legible, and all cast marks shall be on or near the bell. All letters and numerals on pipe sizes 14-inch and larger shall be not less than 0.5-inch in height.

2.3.2.3 Epoxy Exterior Coating –

2.3.2.3.1 Shop Surface Preparation – Abrasive blast to remove loose annealing oxides, all rust and other contaminants. All surfaces shall have a minimum surface profile of 1.5 mils.

2.3.2.3.2 Field Surface Preparation – All abraded areas shall be abrasive blasted to remove all loose rust and shall result in a surface preparation equal to that listed above. All edges shall be feathered. All other surfaces shall be abraded to provide a sufficient surface profile for the proposed finish coat(s).

2.3.2.3.3 Coating – Utilize products by Sherwin Williams, SherGlass FF Epoxy for exposed piping, either above grade or within underground vaults, pits, etc.

For pipe remaining exposed above ground, top‐coating with a urethane

(Acrolon Ultra) for color and gloss retention is required. The table below does not include the standard shop applied primer coating.

Coat Product Color DFT

1st

* SherGlass FF

Epoxy ** White

10.0 – 20.0

2nd

* SherGlass FF

Epoxy ** White

10.0 – 20.0

Final

* Acrolon Ultra **Blue 2.0 – 3.0

* Lining to be applied in a single coat

** Or approved equivalent

2.3.2.6 Soil Corrosion Protection Encasement – When required, DIP shall be encased in plastic sheet material in accordance with AWWA Standard C105 as stated on project plans/specifications if applicable.

2025 Edition Section 2556 – Water Distribution Systems Page 6 of 32

2.3.3 Polyethylene Pipe (HDPE) 4 Inch Through 63 Inch – HDPE pipe shall meet the designations of the “ECUA Pipe Material Chart” and shall be high performance, high molecular weight, high density polyethylene pipe and shall conform to ASTM D 1248

(Type III C, Class C, Category 5). Minimum cell classification values shall be 345434C, as referenced in ASTM D 3350 - latest edition. All pipe resin shall be manufactured by the same company that manufactures the pipe itself in accordance with these specifications to insure complete resin compatibility and total product accountability. The fittings shall be molded or manufactured from a polyethylene compound having a cell classification equal to or exceeding the compound used in the pipe.

2.3.3.1 Quality Control – Refer to the following guidelines regarding quality control.

2.3.3.1.1 The resin used to manufacture the pipe shall be produced by the pipe

Manufacturer, thus maintaining complete control of the pipe quality. The pipe shall contain no recycled compound except that generated in the

Manufacturer’s own plant from resin of the same specification and from the same raw material. The pipe shall be homogeneous throughout and free of visible cracks, holes, foreign inclusions, or other deleterious defects, and shall be identical in color, density, melt index, and other physical properties.

2.3.3.1.2 The Engineer may request, as part of the quality control records submittal, certification that the pipe produced is represented by the quality assurance testing. Additionally, test results from Manufacturer’s testing or random

Manufacturer’s representation, may be cause for rejection of pipe represented by the testing. These tests may include density and flow rate measurements from samples taken at selected locations within the pipe wall and thermal stability determinations according to ASTM D 3350, 10.1.9.

2.3.3.1.2.1 Verification – The Owner or the specifying Engineer may request certified lab data to verify the physical properties of the materials supplied under this specification or may take random samples and have them tested by an independent laboratory.

2.3.3.1.2.2 Rejection – Polyethylene pipe and fittings may be rejected for failure to meet any of the requirements of this specification.

2.3.3.1.2.3 Pipe dimensions – Refer to the ECUA Pipe Material Summary Chart regarding pipe dimensions.

2.3.2.4 Color Coding – HDPE water pipe shall be color-coded with a minimum of two 2-inch wide blue stripes or have an integral, extruded blue coating. Color coding shall be in accordance with FDEP and AWWA requirements, and FAC 62-555.320

2.3.2.5 Approved Manufacturers –All manufactures must obtain documented approval by

ECUA prior to bidding.

2025 Edition Section 2556 – Water Distribution Systems Page 7 of 32

2.3.3 Alternate Pipe Materials – ECUA may consider other pipe materials as appropriate for the needs of the Project. Alternate pipe materials identified during design and approved for use on the Project shall be noted on the Construction Plans, and a detailed Technical

Specification shall be prepared and included in the Contract Documents.

2.4 Water Main Appurtenances –

2.4.1 Water Main Fittings –

2.4.1.1 Ductile Iron Pipe Fittings – Water main fittings shall include Tees, Wyes, Bends, Reducers, and other appurtenances commonly used in pipe construction. Fittings shall be ductile iron meeting AWWA Standard C110 or C153 with pressure ratings of not less than that specified for adjacent pipe. Fittings shall be constructed with mechanical joints, unless otherwise specified, and shall be supplied complete with low alloy bolts and nuts, SBR gaskets and other necessary parts required for field assembly. Fittings shall be cement-mortar lined in accordance with AWWA

Standard C104/A21.4.

2.4.1.2 HDPE Pipe Fittings – Refer to the following guidelines regarding water main fittings:

2.4.1.2.1 Mechanical connections of HDPE pipe sized under 4 inches to ductile iron or PVC piping, mechanical joint fittings, or valves shall be through a self-restraining, fusible mechanical joint adapter. Mechanical joint adapter shall be the same SDR rating as the pipe. Provide the mechanical joint adapter, including but not limited to longer tee bolts and all thread rods with nuts at the mechanical joint bell. Transition fittings of HDPE by male iron pipe threaded end installed by butt fusion shall be used.

2.4.1.2.2 Mechanical connections of HDPE pipe (4 inches and larger) to ductile iron or PVC piping, mechanical joint fittings, or valves shall be through the use of the above specified mechanical joint adapter.

2.4.1.3 Pipe Couplings – Refer to the following guidelines regarding pipe couplings:

2.4.1.3.1 Pipe couplings shall be solid sleeve type with mechanical joints at each end containing a compression gasket. Couplings shall be ductile iron, 12 inches minimum in length, with low alloy bolts and nuts, and SBR gaskets.

Rings and gaskets shall be sized to conform exactly to the requirements of the pipe Manufacturer.

2.4.1.3.2 For transition between asbestos cement and PVC or DI pipe types, Hymax

2000 Series, Romac Macro HP, Couplings, or ECUA approved equal, shall be used.

2.4.1.3.3 Polyethylene pipe and fittings may be joined using approved electro fusion couplings. Fittings shall be PE3408 HDPE. Electro fusion fittings shall have a pressure rating equal to the pipe.

2025 Edition Section 2556 – Water Distribution Systems Page 8 of 32

2.4.1.4 Pipe Cut-in Sleeves – Cut-in sleeves shall be solid ductile iron, one end plain for insertion to female fitting, the other end flanged mechanical joint, furnished with loose attaching flange and fastener, nominal length of 20-21 inches. Specify pipe main size and type of pipe fabrication.

Approved Manufacturers – Pipe Cut-in Sleeves

Manufacturer Model Application

Clow F-1220 for centrifugally cast or sand cast pipe (special)

F-3459 for all classes of centrifugally cast pipe

Union Foundry 21-4520 21-4610 24-4800

MJ X PE

FLG X PE

MJ X FLG

Others as approved by ECUA in writing.

2.4.1.5 Repair Clamps – Repair clamps shall not be used in the installation of new pipe except with the written permission of the Engineer and ECUA. Repair clamps shall be full circle and selected based on the table below.

Repair Clamp Sizes

Pipe Diameter Maximum Sections

Up to 12-inch Single Section

14-inch to 24-inch Double Section

26-inch and above Triple Section

2.4.1.5.1 Repair clamps shall be composed of stainless steel bands and bolts, DI lugs and full gridded virgin SBR compounded gasket.

2.4.1.5.2 Repair clamps shall be sized so that the OD of the existing pipe being repaired falls within the designated range for the clamp size. Repair clamps shall have ample length to give full gasketing at both ends.

Approved Manufacturers

Manufacturer Model

Ford F1, FS1 (all SS), Fordflex (SS-DI Lugs)

Smith Blair 2XX*

JCM 101,102,103,104,131,132,133,134

Mueller 520, 530

ROMAC CL1

Others as approved by ECUA in writing.

* See Manufacturer’s catalog to complete model numbers by size.

2.4.1.6 Pipe and Fitting Restraints –

2.4.1.6.1 Joint restraints and thrust blocks are required for 90 degree bends, 45 degree bends, tees, tapping sleeves, dead-ends, and fire/flushing hydrants.

Joint restraints shall be used in conjunction with all water line pipe, fittings and appurtenances. Joint restraints shall be used on pipe and fittings in each direction in accordance with ECUA Standard Details D-52 and D-62.

2025 Edition Section 2556 – Water Distribution Systems Page 9 of 32

2.4.1.6.2 Restraints shall have set or anchor screws used to secure body to pipe with torque limit break away head design. Alternately, fittings with integral restraint mechanisms (“One-Bolt”) may be used with the approval of the

ECUA Engineer.

Approved Manufacturers

Manufacturer Model

Ebaa Iron Works MegaLug Series 1100, 1500, 2000, 2500, 3000, 3600, 6500

Ford UNI-Flange UAI, UBI, UI, 1300, 1340, 1390, 1400

Sigma SLC, SLD, PVP

Star Pipe Products Series 3000 for 3” – 48” ductile iron

ROMAC Grip Ring / Roma Grip / 600 series

Tyler Union TufGrip

SIP Inc. EZD, EZP, PTP, PTPDF, PTPFC

Others as approved by ECUA in writing.

2.4.1.7 Expansion Joints – Refer to the following guidelines regarding expansion joints:

2.4.1.7.1 Expansion joint fittings shall be used where specified on the Construction

Plans. They shall be of the rigid or flexible type as specified, and manufactured of ductile iron in accordance with the table in Paragraph

2.4.1.5. They shall be capable of expanding or contracting to the extent specified by the Engineer, but in no case less than 4-inches axially, and designed to prevent separation beyond the maximum extension without the use of external tie rods.

2.4.1.7.2 Fittings shall be flanged or provided with restrained mechanical joints, individually pressure tested to a minimum of 350 psi against their own restraints, and internally coated on all exposed surfaces with a minimum of

15 millimeters of fusion bonded epoxy conforming to AWWA C116. They shall be capable of deflecting at least 15 degrees by means of an integral ball at each joint in the case of flexible types.

Approved Manufacturers

Type Manufacturer Model

Rigid EBAA Iron, Inc. EX-TEND 200

Flexible EBAA Iron, Inc. Flex-Tend

Others as approved by ECUA in writing.

2.4.1.8 Tapping Sleeves – Refer to the following guidelines regarding tapping sleeves:

2.4.1.8.1 The minimum size tapping sleeve shall be 4-inches. Connection of 3-inch lines to existing pipes 4-inches and larger shall be made by a 4-inch tapping sleeve with appropriate reducing fitting. Tapping saddles shall be used for smaller connections.

2.4.1.8.2 Tapping sleeves shall be designed for a working pressure of 200 psig without leakage. Tapping sleeves shall be all stainless steel including

2025 Edition Section 2556 – Water Distribution Systems Page 10 of 32 stainless steel flange. The outlet branch connection shall have a recessed flanged face for connection of tapping valve with standard dimensions in accordance with Manufacturers Standardization Society (MSS) SP-60. A complete set of neoprene or other elastomer gaskets shall be furnished.

Sleeves shall be furnished to fit ductile iron, cement-asbestos, or Class 160 or C900/905 PVC pipe with side connection as shown on plans or specifications in standard pipe sizes. Sleeves shall be furnished with all necessary installation parts.

Approved Manufacturers

Manufacturer Model

Ford FAST

Mueller H-304SS

JCM Industries 432

Romac

Smith-Blair 663, 665

Note: To specify exact fitting when ordering, confirm line outside diameter and material. Confirm compatibility of selected fitting with existing main material.

2.4.2 Pipe Hangers and Supports – Hangers and supports shall be in compliance with Federal Specification WW-H-171E, or Manufacturer’s Standardization Society SP-69, or UL listed.

Materials of construction shall be in accordance with the requirements outlined in the table below.

Approved Materials for Construction of Pipe Hangers and Supports

Part I.D. Material

Clamps Steel - Epoxy Coated or Galvanized Cast Iron - Galvanized Malleable Iron

Hanger Rods Steel - Electro Galvanized Steel - Stainless 304

Roller Bases/Roller Stands Cast Iron

Fasteners/Fittings Galvanized Steel Stainless

Hanger Rod Inserts Steel - Cadmium Plated Steel - Galvanized Universal Concrete Insert - Cast Iron - Galvanized

Rod Attachments Clevis - Forged Steel Turnbuckle: 1) Forged Steel, 2) Malleable Iron Sockets, Eye Nuts, Extension - Malleable Iron

Roller Bases/Roller Stands Cast Iron

Rollers Steel or Iron Core, Insulated from Structure

2025 Edition Section 2556 – Water Distribution Systems Page 11 of 32

Approved Manufacturers – Pipe Hangers and Supports

Manufacturer Part I.D. Model No.

Utility Pipe Sales Clevis Hanger 590

Socket Clamp 224

Concrete Inserts:

CB-Universal Screen Insert

Rod Attachments:

Eye Nut Forged Clevis Forged Turnbuckle Carbon Steel Couplings Socket Eye Extension

110R

Pipe Rolls:

Adjustable Swivel Adjustable Steel Yoke

Pipe Roll with Base 274

Pipe Roll and Plate 277

2.4.3 Valves – All valves shall be manufactured in accordance with the current appropriate

AWWA Standard and shall be NSF approved for use in potable water.

2.4.3.1 Resilient Seated Gate Valves – Resilient seated gate valves shall be designed and fabricated in accordance with the current AWWA Standard C-509 or C-515. The basic design of the gate valves shall have an iron body, elastomer encapsulated iron disc, bronze stem and operating nuts with non-rising stem design. When circumstances dictate, valves 24-inches and larger may be equipped with right angle gears (bevel gearing) for horizontal installation. The valve working pressure for all sizes shall be a minimum of 250 psig with a test pressure of 500 psig.

2.4.3.1.1 Materials and Construction – Valves shall open counterclockwise with a 2-inch square iron operating nut secured to the valve stem by a corrosion resistant Type 304 stainless steel nut to threads on the valve stem. The valve stem shall be made of high tensile strength bronze and shall be of one piece construction sealed by O-Rings. The thrust collar shall be secured in place by a stuffing box or bonnet cover with a thrust washer located above the thrust collar. Valve construction shall be so that upper

O-Rings can be replaced with the valve in service. The disc shall be cast iron encapsulated with an elastomer material bonded in accordance with

ASTM D429 and shall be secured to the threaded stem by a bronze nut.

The disc shall effect a seal that is bubble-tight at 250 psig.

2025 Edition Section 2556 – Water Distribution Systems Page 12 of 32

2.4.3.1.2 Body-Disc-Bonnet-Operating Nut Material – Cast ductile iron construction in accordance with current AWWA Standard C-509 and C-515 and AWWA

Standard C-153. Body bolts shall be equipped with square or hex head bolts for easy removal.

2.4.3.1.3 Corrosion Resistant Coatings – All interior and exterior cast iron surfaces shall be coated with fusion bonded epoxy in accordance with AWWA

Standard C-550.

2.4.3.1.4 Body Sizing – Valve body length shall be per ASME/ANSI B16.20 for the type of end connections specified. In the full open position, the valve internal bore shall be smooth and obstruction-free without cavities or projections that could accumulate solids. The internal cross-sectional area of the valve shall be approximately equal to the nominal cross-sectional area for Schedule 40 PVC pipe of the same nominal internal diameter.

2.4.3.1.5 End Connections – Refer to the following guidelines regarding end connections:

2.4.3.1.5.1 Valves shall be furnished with mechanical joint end connections, complete with accessory kits, unless otherwise specified on the plans or purchase order.

2.4.3.1.5.2 When flanged ends are specified they shall be flat face class 125, conforming to ASME/ANSI B16.1 with bolt holes straddling the vertical center line.

Approved Manufacturers - Resilient Seated Gate Valves

Manufacturer & Specs

Valve Body Connections Mechanical

Joint Flange &

Mechanical Joint Flanged

End Mechanical Joint for Tapping

(MJxMJ) (FLGxMJ) (FLGxFLG) (MJxSF)

American Flow Control

Size: 2" - 12" 2" - 12" 2" - 12" 2" - 12"

Model No.:

AFC2500 AFC2500 AFC2500 AFC2500

Clow

C -5

Size: 2" - 12" 3" - 12" 2" - 12" 3" - 12"

No.:

F-6100 F-6106 F-6102 F-6114

C -5

Size: 4" - 48" 4" - 48" 4" - 48" 4" - 24"

No.:

F-6100 F-6106 F-6102 F-6114

Kennedy

C -5

Size: 2" - 12" 3" - 12" 2" - 12" 4" - 12"

8571SS 8572SS 8561ASS 8950SS

No.:

7571SS 7572SS 7561SS 7950SS

M&H

C -5

4067-01 4067-13 4067-02 4751-01

Size: 2" - 16" 3" - 16" 2" - 16" 4" - 16"

7571 7572 7561 7950

2025 Edition Section 2556 – Water Distribution Systems Page 13 of 32

Mueller

C -5

Size: 3” - 12” 3” - 12” 3” - 12” 3” - 12”

A-2362 A-2362 A-2362 A-2362

Size: 4” - 54” 4” - 54” 4” - 54” ---

No.:

A-2361 A-2361 A-2361 ---

2.4.3.2 Resilient Seated Tapping (Gate) Valves – Resilient seated gate valves shall be designed and fabricated in accordance with the current AWWA Standard C-509 or

C-515. The basic design of the gate valves shall have an iron body, elastomer encapsulated iron disc, bronze stem and operating nuts with non-rising stem design. When circumstances dictate valves 16-inches and larger shall be equipped with right angle gears (bevel gearing) for horizontal installation only with ECUA approval. The valve working pressure for all sizes shall be a minimum of 250 psig with a test pressure of 500 psig.

2.4.3.2.1 Materials and Construction – Valves shall open counterclockwise with a 2-inch square iron operating nut secured to the valve stem by a corrosion resistant (Type 304 Stainless Steel) nut to threads on the valve stem. The valve stem shall be made of high tensile strength bronze or 304 stainless steel and shall be of one piece construction sealed by O-Rings. The thrust collar shall be secured in place by a stuffing box or bonnet cover with a thrust washer located above the thrust collar. Valve construction shall be so that upper O-Rings can be replaced with the valve in service. The disc shall be iron encapsulated with an elastomer material bonded in accordance with ASTM D429 and shall be secured to the threaded stem by a bronze nut. The disk shall effect a seal that is bubble-tight at 250 psig.

2.4.3.2.2 Corrosion Resistant Coatings – All interior and exterior cast iron surfaces shall be coated with fusion bonded epoxy in accordance with AWWA

Standard C-550.

2.4.3.2.3 Body Sizing – Valve body length shall be per ASME/ANSI B16.20 for tapping valves. Tapping valves shall conform to Specification AWWA

C509 or C515, latest revision, covering gate valves except as modified for passage and clearance of tapping machine cutters. The opening through the valve shall be at least 1/4-inch larger than nominal valve diameter.

Tapping valves shall allow full size shell cutters to be used.

2.4.3.2.4 End Connections – Valves shall be furnished with one end of the body with projecting face flange in accordance with specification MSS SP-60 for tapping valve/saddle connections to bolt to a standard tapping sleeve and the other end for mechanical joint.

2.4.3.3 Butterfly Valves – All butterfly valves shall be of the rubber-seated, tight-closing type. They shall meet or exceed AWWA Standard C504. All valves must use full

AWWA C504 Class 150B valve shaft diameter, and full Class 150B underground service operator torque rating throughout entire travel, to provide capability for operation in emergency service.

2025 Edition Section 2556 – Water Distribution Systems Page 14 of 32

2.4.3.3.1 Valve Construction – Valve body shall be high-strength ductile iron ASTM

A126 with ASTM 276 18-8 Type 304 stainless steel body seat. Valve vane shall be high-strength cast iron ASTM A126, having rubber seat mechanically secured with an integral 18-8 stainless steel clamp ring and

18-8 stainless steel self-locked screws. Shaft shall be one piece ASTM

276 Type 304 stainless steel. Bearings shall be sleeve-type, self-lubricated with O-Ring seals.

2.4.3.3.2 Operators – Operator shall be of the traveling-nut type, sealed, gasketed, and lubricated for underground service. It shall be capable of withstanding an overload input torque of 450 ft. lbs. at full-open or closed position without damage to the valve or valve operator. Operator shall have operating nut or post indicator as specified.

2.4.3.3.3 End Connection – End connections shall be mechanical joint, wafer-type with flange meeting ANSI B16.1 Class 125, and furnished as specified.

Approved Manufacturers

Manufacturer Model

Clow F-53XX*

M & H 450, 1450, 4500

Others as approved by ECUA in writing.

* XX: See Manufacturer’s catalog to complete model numbers by size.

2.4.3.4 Valve Insertions –

Approved Manufacturers

Manufacturer Size Range

Romac 4” – 42 “ Hydra-Stop 4” – 12”

EZ Valve 4”-24” Others as approved by ECUA in writing.

2.4.4 Valve Boxes – Valve boxes shall be provided for all direct buried valves. Use nominal (5 ¼) inch cast-iron, slip-type or screw-type pipe shaft with cover and base casting. The box top shall be set at finished grade and encased with a concrete ring in unpaved areas.

Each valve box shall be furnished with a drop-in cover marked “WATER”. See ECUA Standard Detail D-43.

2.4.5 Line Stops – Line stops are to be used where specified to temporarily stop water line water flow without depressurizing the entire line. The line stop parts and installation equipment are to be rated at a minimum of 150 psig working pressure unless otherwise specified.

2.4.5.1 Materials and Construction – Tapping saddles shall have 360-degree clamping on the main. All tapping saddles shall be fabricated of 304 Stainless Steel. All bolts and fasteners are to be 304 Stainless Steel, and the saddle shall be installed with Buna-N or neoprene rubber full facing gasket.

2025 Edition Section 2556 – Water Distribution Systems Page 15 of 32

2.4.5.1.1 The stopping device attaching nozzle to be vendor’s standard with connecting threads or flange face, and the nozzle I.D. to be manufactured with a shelf to provide a position stop for the closure plug.

2.4.5.1.2 The closure plug is to be fabricated carbon steel, ductile iron, or malleable iron with at least one Buna-N or neoprene O-Ring seal on the outside diameter.

2.4.5.2 Corrosion-Resistant Coatings – Non-stainless steel permanently installed parts to have Manufacturer’s standard red or black water base epoxy coating.

2.4.5.3 Connection – Tapping saddle shall be fabricated with dimensions to fit on concrete, steel, CA, PVC, CI, DI main as specified.

2.4.5.4 Installation – Temporary line stops shall only be installed by vendor personnel or Contractor Personnel trained and certified for stop by the vendor.

Approved Manufacturers

Manufacturer Model

Romac SST - X

JCM 440

Hydra-Stop HSF 250

Others as approved by ECUA in writing.

2.4.6 Location Aids – All new water main and service line installations shall include an approved method for locating lines from the ground surface after completion.

2.4.6.1 Tracer Wire – Tracer wire for force mains shall be minimum 12 gauge solid copper with 30 mil minimum thickness green insulation and minimum break load of 180 lbs. for open trench installation. For trenchless installation, two wires, 8- gauge solid copper with 45 mil minimum thickness with green insulation and a minimum break load of 485 lbs. Tracer wire systems shall be electrically continuous covering all mains within the project. For wire to wire connections, contractor shall use lockable connectors specifically designed for direct burial, dielectric silicone gel filled, designed to prevent uninsulated wire exposure. Wire-to-appurtenance attachments shall be made with lug-type terminals.

2.4.6.2

Approved Manufacturers (Tracer Wire Silicone-filled Wire Nut Connectors)

Manufacturer Model

Ideal Industries Twister® DB Plus

King Technology, Inc. Failsafe™

Others as approved by ECUA in writing.

2.4.6.3 Pipeline Markers – When specified, markers shall be of a passive electronic type that reflects a signal back to an electronic hand-held transmitter/detector.

Electronic components shall be enclosed in a blue waterproof polyethylene housing. Markers shall have a different response frequency for each service line type.

2025 Edition Section 2556 – Water Distribution Systems Page 16 of 32

2.4.6.3.1 Markers shall be ScotchMark products manufactured by 3M Telecom Systems Group, Austin, Texas. Alternate Manufacturers by ECUA in writing.

Pipeline Markers

Application Usable Depth Dimension/Configuration Service Model

Near Surface 2 Feet 3½”L X 5/8” Cylinder Water 1434

Medium Depth 4 Feet 4” Ball Water 1403

Deep 6 Feet 8” X 1” Thick Disc Water 1257

2.5 Hydrants and Flushing Equipment –

2.5.1 Fire Hydrants – Fire Hydrants shall be in compliance with the AWWA Standard C-502, with rated working pressure of 250 psig. The basic design of the fire hydrant shall be of the dry barrel type of breakaway traffic design. Use 304 stainless steel bolting below grade, and use fusion bond epoxy coating on mechanical joint inlet shoe, per AWWA C-

550. See ECUA Detail D-50 for other requirements.

2.5.1.1 Hydrant Construction – Refer to the following guidelines regarding hydrant construction:

2.5.1.1.1 The hydrant inlet connection shall be 6-inch mechanical joint type complete with Accessory kit.

2.5.1.1.2 The hydrant shall be designed with a safety feature incorporating a break-away flanged design. Split ring retainer-type breakaway design with pinch bolts is not acceptable. The hydrant design shall allow the upper barrel to be rotated 360 degrees in order to assure proper nozzle orientation.

2.5.1.1.3 The drain valve shall assure quick and complete drainage of the hydrant and the drain hole shall be brushed with bronze if passing through ductile iron. The drain valve sealing facing shall be made of Buna N, nylon or urethane. If the valve top plate comes in contact with the bronze seat ring to facilitate draining of the hydrant, the valve top plate shall be made of bronze.

2.5.1.2 Main Hydrant Valve – Refer to the following guidelines regarding main hydrant valve:

2.5.1.2.1 The main hydrant valve shall be compression type, opening counterclockwise against system pressure and closing clockwise with system pressure. The main valve connection opening shall not be less than 5¼-inches. The main valve shall have a resilient seat.

2.5.1.2.2 The hydrant shall be designed such that the operating threads on the stem are prevented from coming in contact with potable water and shall be enclosed in an operating chamber and sealed by O-Rings at the top and bottom of the chamber. The chamber shall be constructed for grease or oil lubrication with an installed grease fitting for maintenance.

2.5.1.2.3 The operating nut shall be 1½-inches in size and pentagon in shape and of one-piece construction.

2025 Edition Section 2556 – Water Distribution Systems Page 17 of 32

2.5.1.2.4 The hydrant shall have one 4½-inch pumper nozzle, and two 2½-inch pumper nozzles having National Standard Hose coupling threads. The nozzles shall be field replaceable utilizing either a threaded or quarter-turn fitting with an O-Ring seal.

2.5.1.3 Operation and Maintenance Features – Refer to the following guidelines regarding operation and maintenance features:

2.5.1.3.1 The hydrant shall not incorporate parts requiring field adjustment for proper operation.

2.5.1.3.2 The hydrant shall be designed to permit the removal of all working parts from the hydrant through the barrel without disturbing the earth around the hydrant.

2.5.1.3.3 Removal of the working parts of the hydrant shall be accomplished by use of a seat removal wrench. Hydrants requiring other special tools to perform removal of interior parts will not be accepted.

2.5.1.4 Materials – All operating parts including operating nut, hold-down nut, drain ring and seat ring shall be bronze. The valve seat ring shall thread into a bronze insert or drain ring to provide bronze-to-bronze seating. Breakaway stem coupling is to have bronze or stainless steel bolts or pins.

2.5.1.5 Markings – The fire hydrant shall have permanent markings identifying the Manufacturer by name, initials or insignia, the size of the main valve opening, and the year of manufacture.

2.5.2 Fire Hydrant Appurtenances –

2.5.2.1 Extensions Kits – Refer to the following guidelines regarding extension kits:

2.5.2.1.1 Where required, hydrants shall be installed using original Manufacturer hydrant extension kits as necessary to position the hydrant breakaway flange above finish grade per ECUA Standard Detail D-50.

2.5.2.1.2 Stand extension shall be in standard lengths of 12, 24, 36, 48, and 60 inches.

2.5.2.2 Hydrant Connectors – Refer to the following guidelines regarding hydrant connectors:

2.5.2.2.1 Hydrant connector spools shall be ductile iron per AWWA C151 used for connection between the hydrant and lead valve, and shall incorporate joint

Approved Manufacturers

Manufacturer Model No.

Clow F2545

M & H 129T

Mueller A423

2025 Edition Section 2556 – Water Distribution Systems Page 18 of 32 restraints. One end of the connector spool shall have swivel flange. See ECUA Standard Detail D-50.

2.5.2.2.2 Hydrant Offset Connectors – When a height adjustment is required to avoid an obstruction between the hydrant shut-off valve and the hydrant, an offset fitting shall be used. Material to be ductile iron per ANSI/AWWA C153/A21.53. Sizes shall be as follows:

6-inch X 18-inch long with 6-inch offset

6-inch X 30-inch long with 12-inch offset

6-inch X 41-inch long with 24-inch offset

Approved Manufacturers

Manufacturer Straight Hydrant Connector Offset Connector

Assured Flow Sales, Inc. N/A GRADELOK

Clow ✓ N/A

Others as approved by ECUA in writing.

2.5.3 Flushing Hydrants – Flushing hydrants shall be in general compliance with AWWA Standard C-502, with rated working pressure of 200 psig. Pipe supplying flush hydrant shall match the diameter of the water main. A fully restrained gate valve shall be installed at each flushing hydrant per ECUA Standard Detail D-51.

2.5.3.1 Hydrant Construction – Flushing hydrants shall meet the requirements of Paragraph 2.5.2.1, except the breakaway feature is not required.

2.5.3.2 Main Valve – Generally the same as Paragraph 2.5.1.2, except main valve opening shall be not less than 2-1/8 inches and the flushing hydrant shall have one

(1) 2½-inch nozzle having national standard hose coupling threads.

2.5.3.3 Operation and Maintenance Features – Unless otherwise specified, the hydrant bury length shall be 30-36 inches. The bury length is the distance measured to the nearest 1/2 foot, from the bottom of the connecting pipe to the ground line of the hydrant.

2.5.3.4 Materials – All operating parts including operating nut, hold-down nut, drain ring and seat ring shall be bronze. The valve seat ring shall thread into a bronze insert or drain ring to provide bronze-to-bronze seating.

2.5.3.5 Markings – Flushing hydrant markings shall meet the requirements of Paragraph

2.5.1.5 for fire hydrants.

Approved Manufacturers

Manufacturer Model

M & H Style 33

Mueller A-411

2.6 Water Service Lines –

2025 Edition Section 2556 – Water Distribution Systems Page 19 of 32

2.6.1 Polyethylene Tubing (HDPE) – Polyethylene service tubing shall meet the designations of the “ECUA Pipe Material Chart” for water supply. However, only sizes up to 2 inches will be allowed. All tubing must have a minimum cell classification of ASTM D3350, 445574E blue in color. PE tubing dimensions shall conform to ASTM D2737 with Copper Tubing OD base. Refer to paragraph 2.3.3 for service lines greater than 3 inches in diameter. All services shall be one continuous pipe with no couplings.

2.6.1.1 Markings – Use the Following Markings:

2.6.1.1.1 Nominal Size

2.6.1.1.2 Standard PE Code: 4710

2.6.1.1.3 Tubing: DR-9

2.6.1.1.4 Pressure Class: PC200

2.6.1.1.5 Manufacturer’s Name or Trademark

2.6.1.1.6 Date Manufactured

Approved Manufacturers

Manufacturer Model

Endot Industries Endopure

Others as approved by ECUA in writing.

2.6.2 Copper Water Service Tubing – Copper water service tubing shall be Type K suitable for underground potable water services. Tracer wire is not required with copper tubing.

2.6.2.1 Material – Tubing is to be supplied in conformance with ASTM B88 for dimension and materials.

2.6.2.2 Pressure Rating – Test pressure shall be 200 psi. Operating pressure shall be 150 psi. Refer to the table below.

Copper Water Tubing Dimensions (ASTM B88)

Size (inches) Nominal OD Wall Thickness

1 1.125 .065

2 2.125 .083

2.6.2.3 Pipe Markings – Use the following markings:

2.6.2.3.1 Nominal Size

2.6.2.3.2 Type K

2.6.2.3.3 ASTM B88

2.6.2.3.4 Manufacturer’s Name or Logo

2.6.2.3.5 NSF Seal

2025 Edition Section 2556 – Water Distribution Systems Page 20 of 32

2.6.2.3.6 Date Manufactured

2.6.3 Pipe Sleeves for Long Water Services – Long water services shall be sleeved in PVC or PE pipe color coded blue or black with blue stripes. The sleeves shall be a minimum of 2-inch diameter with no fittings and shall extend one-foot either side of the paved surface and/or sidewalk. The sleeve shall be one continuous leak free piece which is open on each end. The long service shall be sized according to the table shown below.

Pipe Sleeve Sizing For Long Water Services

Service Size (inches) Sleeve Size (inches)

1 2

2 4

2.7 Service Line Appurtenances –

2.7.1 Fittings and Valves – Fittings and valves shall be manufactured in accordance with AWWA C-800 and be listed and approved by NSF for underground use in potable water service.

2.7.1.1 Material – Refer to the following guidelines regarding material:

2.7.1.1.1 Fitting and valve bodies, plugs, and compression nuts shall be bronze, copper alloy no. C83600 and meet chemical and mechanical requirements of ASTM B62 or ASTM B584.

2.7.1.1.2 Component parts such as fasteners, seals, and packing may be of other materials selected for adequate endurance, corrosion resistance and strength in accordance with AWWA C-800.

2.7.1.2 Pressure – Fittings and valves shall be high pressure type for maximum allowable pressure of 150 PSIG, nominal operating pressure 100 psig.

2.7.1.3 Markings – Fittings and valves shall be marked as appropriate with the following information: Manufacturer’s name or logo; pressure rating; direction of flow; and size.

2.7.1.4 Thread Specifications - Refer to the following table regarding thread specifications:

Thread Specifications

Thread Type Standard

Unified Inch ANSI/ASME B1.1

General Purpose Pipe ANSI/ASME B1.20.1

Dryseal ANSI/ASME B1.20.3

2.7.1.5 Pack Joint Couplings – Refer to the following table regarding pack joint couplings:

Pack Joint Couplings

Type Manufacturer Model

Copper or Plastic Tube X MPT

Ford Mueller

C84-XX

H-15428-X

Copper or Plastic Ford C14-XX

2025 Edition Section 2556 – Water Distribution Systems Page 21 of 32

Tube X FPT Mueller H-15451-X

Copper or Plastic Tube to Tube

Ford Mueller

C44-XX

H-15403-X

Female Copper Pipe (replaces flare nut) X Copper or Plastic Tubing

Ford

Mueller

CO4-XX

H-15071-X

* XX: See Manufacturer’s catalog to complete model numbers by size.

2.7.1.6 Tapping Saddles – Tapping saddles shall be either bronze or ductile iron with shop coat, with the exception of saddles for PE pipe. Saddles used to tap Class 160 PVC pipe shall be designed with mechanical features or stops to prevent over-tightening.

2.7.1.6.1 Saddle Sizes – Use the following saddle sizes:

2.7.1.6.1.1 Main Pipe: 2-inch and above

2.7.1.6.1.2 Tap Size: 1-inch, or 2-inch

2.7.1.6.1.3 Refer to the following table regarding saddle sizes:

Mainline Pipe Manufacturer Model

Size Material

2” – 12” IPS PVC

Ford S-70

Mueller S-13000

4”+

Ductile Iron or Cast Iron

Ford F202 Mueller DR2A

Smith-Blair 313 Romac 202U

DI, CI, C900 PVC,

A/C

Ford FCD202 Mueller DR2S

Smith-Blair 317 CI, C900 PVC, A/C Romac 202NS

2.7.1.7 Water Tubing Couplings – Water tubing couplings in sizes 1-inchand 2-inch only shall be bronze compression-type, inlet and outlet for PE or copper tubing. Crimp-type couplings are not acceptable.

Acceptable Manufacturers

Manufacturer Model

Ford C44-XX-NL*

Mueller H-15403-XX*

Others as approved by ECUA in writing

* XX: See Manufacturer’s catalog to complete model numbers by size.

2025 Edition Section 2556 – Water Distribution Systems Page 22 of 32

2.7.1.8 Meter Couplings – Meter couplings shall be bronze and sized as appropriate to accommodate the relevant meter. Inlet shall have male pipe thread.

* XX: See Manufacturer’s catalog to complete model numbers by size.

2.7.2 Service Line Valves –

2.7.2.1 Corporation Stops – Corporation stops shall be brass, high-pressure class, ball type, with inlet taper CC thread. Outlet shall be compression-type for PE or copper tubing. Corporation stops shall be sized for 1-inch, or 2-inch tubing as appropriate.

Acceptable Manufacturers

Manufacturer Model

Ford F-1000 and FB-1000

Mueller 300, P15008 Ball-type

Others as approved by ECUA in writing.

2.7.2.2 Curb Stops – Curb stops shall be brass, high pressure, ball-type with locking wings. Inlet shall be compression-type for PE tubing. Outlet shall be female iron pipe threads. Curb stops shall be sized for 1-inch, or 2-inch tubing as appropriate.

2.8 Backflow Prevention Assemblies – Backflow prevention assemblies shall be manufactured in accordance with AWWA C-510 and AWWA C-511, and shall also be approved by ASSE and/or approved by NSF for use in potable water systems with a maximum continuous operating pressure of 150 psig, and capable of sustaining a hydrostatic test pressure of 300 psig. Backflow prevention devices shall be located immediately downstream of the Owner’s control valve.

2.8.1 Materials and Construction – The body shall be cast iron with hot dip galvanized coating or fusion bonded epoxy on the interior and exterior, or cast bronze with a maximum lead content of 5 percent. Working parts and springs shall be bronze or stainless steel; valve discs shall be silicone rubber; diaphragms shall be fabric reinforced neoprene, and O-rings shall be Buna-N, neoprene, or silicone rubber. Check valve enclosures shall be glass-filled nylon or Teflon, or bronze or stainless steel. Other working parts shall be bronze or stainless steel.

2.8.2 Double-Check Valve – A double check valve assembly (DC) is a mechanical backflow preventer that consists of two independently acting, spring-loaded check valves. It includes shutoff valves at each end of the assembly and is equipped with test cocks. A

Acceptable Manufacturers

Manufacturer Model

Ford C38-XX*

Mueller H-15428-XX*

Others as approved by ECUA in writing

Acceptable Manufacturers

Manufacturer Size Model

Ford 1-inch 2-inch

B41 – 444W B41 –777W

Mueller 1-inch 2-inch

2025 Edition Section 2556 – Water Distribution Systems Page 23 of 32

DC is effective against backpressure backflow and backsiphonage but should be used to isolate only non-health hazards.

2.8.3 Reduced Pressure Assembly – A reduced pressure valve assembly (RP) is a mechanical backflow preventer that consists of two independently acting, spring-loaded check valves with a hydraulically operating, mechanically independent, spring-load pressure differential relief valve between the check valves and below the first check valve.

2.8.4 Pressure Vacuum Breaker – The pressure vacuum-breaker assembly (PVB) is a mechanical backflow preventer that consists of an independently acting, spring-loaded check valve and an independently acting, spring loaded, air inlet valve on the discharge side of the check valve. It includes shutoff valves at each end of the assembly and is equipped with test cocks. A PVB may be used to isolate health or non-health hazards but is effective against backsiphonage only and can only be used in an irrigation setting.

2.8.5 Appurtenances – All backflow assemblies shall be provided and installed as a complete assembly with all necessary fittings to enable testing in place. Tapped test ports shall be fitted with test petcocks in each body cavity. Inlet and outlet gate or ball valve shall be of the same line size as that of the body.

2.8.6 Approved Assemblies – The word “approved” when used with reference to a backflow prevention assembly, an assembly which has been manufactured in full conformance with the standards established by the American Water Works Association titled: AWWA C510- 89 Standard for Double Check Valve Backflow Prevention Assembly, or AWWA C511-89 Standard for Reduced-Pressure Principle Backflow Prevention Assembly, as such standards may be amended from time to time, and which comply with the laboratory and field performance specifications of the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California established by “Specification of Backflow-Prevention Assemblies” - Section 10 of the most current issue of the Manual of Cross-Connection Control and in accordance with the ECUA guidelines.

2.9 Yoke Box Assemblies – Meter box assemblies for 5/8-inch meters shall be cast iron open bottom per ASTM A-48 with plastic lid with ECUA imprint. The box assembly shall include a ball valve with locking nuts, pack joint coupling for copper or PE tubing with expansion connection and gaskets as needed.

Acceptable Manufacturers

Manufacturer Model Meter Size

Ford G148-133-PB-NL (modified) w/ 1” pack joint for copper or PE tubing

5/8”

Others as approved by ECUA in writing

2.10 Meter Box Assemblies – Meter box assemblies for 1-inch meters shall use plastic meter boxes. 1 ½-inch meters shall use jumbo meter box. Meter box and cover for meters 2-inch and larger shall be constructed in accordance with ECUA Standard Details D-44 and D-45.

Acceptable Manufacturers

Manufacturer Model Meter Size

Carson 1015-12 with C. I. reading lid 1”

1015 with C. I. reading lid 1.5”

Pentax 170111 with C. I. reading lid 1”

2025 Edition Section 2556 – Water Distribution Systems Page 24 of 32

190111 with C. I. reading lid 1.5”

Others as approved by ECUA in writing

PART 3: Execution

3.1 General – The Contractor shall provide all labor, equipment and…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .