SDSU Agricultural Heritage Museum Historic Roof Repairs Drawings.pdf

PDF 915 KB Posted

Attached to
SDSU-Agricultural Heritage Museum Historic Roof Repairs
Solicitation number
24IFB10715
Issued by
Brown County, South Dakota

About this file

This document is a government file related to a state and local contract opportunity for the historic roof replacement project at the South Dakota Agricultural Heritage Museum on the South Dakota State University campus in Brookings, South Dakota. The project involves the removal, salvage, and reinstallation of approximately 12,000 square feet of existing French clay roofing tiles, ridge, and hip caps, as well as the removal and disposal of roofing membrane, asphalt underlayment, miscellaneous rough carpentry, and deteriorated decorative wood carpentry. New construction will include roofing membrane, underlayment, ice & water shield, copper flashing, copper gutters, 20% replacement clay roofing tiles, rough carpentry, ornamental carpentry, sealants, and exterior paint. The estimated project cost is under $800,000. A pre-bid meeting is scheduled for April 18, 2024, and bids are due by April 25, 2024.

The contract will be a single prime contract. Pricing terms, set-asides, funding requirements and sources, and other salient information are not provided in the document. The current incumbent, if any, is not specified.

View the file

Other files

File Type Posted
Project Manual.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11TH STREET

M

ED

AR

Y

AV

EN

U E

CONSTRUCTION

STAGING ZONE

TREE

PROTECTION

ZONE

RAMP

POTENTIAL TRAFFIC

CONTROL ZONE

Not to Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

AG HERITAGE MUSEUM

HISTORIC ROOF REPLACEMENT

SOUTH DAKOTA STATE UNIVERSITY

BUILDING #: 0601

WO# 22-109330

SCOPE OF WORK SUMMARY:

PROJECT CONSISTS OF THE REMOVAL, SALVAGE, AND REINSTALLATION OF

APPROXIMATELY 12,000 SQUARE FEET OF EXISTING FRENCH CLAY ROOFING TILES,

RIDGE, AND HIP CAPS. THE PROJECT ALSO INCLUDES THE REMOVAL AND DISPOSAL

OF ROOFING MEMBRANE, ASPHALT UNDERLAYMENT, MISCELLANEOUS ROUGH

CARPENTRY, AND DETERIORATED DECORATIVE WOOD CARPENTRY. NEW

CONSTRUCTION WILL INCLUDE ROOFING MEMBRANE, UNDERLAYMENT, ICE & WATER

SHIELD, COPPER FLASHING, COPPER GUTTERS, 20% REPLACEMENT CLAY ROOFING

TILES, ROUGH CARPENTRY, ORNAMENTAL CARPENTRY, SEALANTS, AND EXTERIOR

PAINT. COPPER DOWNSPOUTS ARE TO BE SALVAGED AND REINSTALLED. INSPECT

THE EXISTING TONGUE & GROOVE ROOF DECKING AND SHEET DECKING FOR

DAMAGE AND IRREGULARITIES, REPAIR AS REQUIRED TO MAINTAIN A STABLE

SUBSTRATE FOR THE ROOF ASSEMBLY INSTALLATION.

UNIT PRICES:

PROJECT CONTACTS:

PROJECT MANAGER: CHRISTOPHER GROSS PHONE: (605) 688-6251

PROJECT OWNER: GWEN MCCAUSLAND PHONE: (605) 688-4581

ARCHITECT: JONATHAN MEENDERING PHONE: (605) 688-4975

LOCATION MAP:

A101

SIM

A101

SIM

A101

1 1

SYMBOLS:

SHEET INDEX:

REVISION TAG

WINDOW TAG

DOOR TAG

WALL TAG

KEYNOTE

1t

1i

A01

ROOM NAME

150 SF

ROOM TAG

VIEW TITLE

ELEVATION TAG

CENTERLINE

1 VIEW NAME

SCALE: 1/8"=1'-0"

CALLOUT

INTERIOR ELEVATION

SECTION TAG

ABBREVIATIONS:

ACT ACOUSTICAL CEILING TILE

AFF ABOVE FINISH FLOOR

ALUM ALUMINUM

ANOD ANODIZED

APPROX APPROXIMATELY

BSMT BASEMENT

BTTM BOTTOM OF

CIP CAST IN PLACE

CJ CONTROL JOINT

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

CONC CONCRETE

CONST J CONSTRUCTION JOINT

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

DBL DOUBLE

DEMO DEMOLISH

DIA DIAMETER

DIMS DIMENSIONS

DN DOWN

DTL DETAIL

DWG DRAWING

EA EACH

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

EPDM PROPYLENE DIENE ROOFING

EQ EQUAL

EXIST EXISTING

EXT EXTERIOR

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FLR FLOOR

FO FACE OF

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GWB GYPSUM WALL BOARD

HC HOLLOW CORE

HM HOLLOW METAL

HVAC HEATING VENTILATION & AIR CONDITIONING

INSUL INSULATION

INT INTERIOR

LAV LAVATORY

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MO MASONRY OPENING

MTL METAL

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

OC ON CENTER

PCC PRE-CAST CONCRETE

PLUMB PLUMBING

PNT PAINT/PAINTED

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PVC POLYVINYL CHLORIDE

R RADIUS

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REINF REINFORCED

REQD REQUIRED

RM ROOM

SF SQUARE FOOT

SIM SIMILAR

SOG SLAB ON GRADE

SPEC SPECIFIED OR SPECIFICATION

SPK SPRINKLER

SQ SQUARE

SSTL STAINLESS STEEL

STC SOUND TRANSMISSION COEFFICIENT

STL STEEL

STRUCT STRUCTURAL

T&G TONGUE AND GROOVE

TI TAPERED INSULATION

TO TOP OF

T/D TELEPHONE AND DATA

TELE TELEPHONE

TOS TOP OF STRUCTURE

TOW TOP OF WALL

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

VIF VERIFY IN FIELD

VP VISION PANEL

W/ WITH

WC WATER CLOSET

WD WOOD

Drawn by

1.

2.

3.

4.

5.

6.

TONGUE AND GROOVE ROOF DECKING

COPPER FLASHING AND COPING

EXTERIOR FINISH CARPENTRY

EXTERIOR PAINT

THERMAL INSULATION

WOOD ROOF DECKING, SHEET.

4/ 3/

0:

:5

AM

G001

Title Sheet 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

SOUTH DAKOTA AGRICULTURAL HERITAGE MUSEUM

977 11TH STREET

BROOKINGS SD 57007

G001 Title Sheet G002 Historic Preservation Review D101 Roof Demolition A101 Roof Plan A201 Building Sections A202 Building Sections A221 Details A222 Details A223 Details

No. Description Date

D01D02

D03

D03

50' - 0" 58' - 2" 36' - 10"

6'

0"

145' - 0"

48' - 10" 59' - 0" 37' - 2"

18' - 6" 22' - 0" 18' - 6"

≈270 SF

≈476 SF

≈1376 SF

6"

1' -0

6" / 1'-0"

6"

1' -0

6" / 1'-0"

6"

1' -0

6"

1' -0

6" / 1'-0"

6"

1' -0

4"

1' -0

4"

1' -0

6" / 1'-0" 6" / 1'-0"

6" / 1'-0"

6'

0"

6"

1' -0

6" / 1'-0"

D01

D01

D01

D02

D02

D02

D03

D04

D04

D04

D04

D04

D04

D04

D05

0' 4' 8' 16' 32'

2'

2"

D06

INDICATES EXISTING LOW SLOPE ADHERED MEMBRANE ROOF

INDICATES EXISTING CLAY TILE ROOF

1/8" = 1'-0"1 Roof Demolition

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 1/8" = 1'-0"

4/ 3/

0:

:5

AM

D101

Roof Demolition 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

DEMOLITION GENERAL NOTES:

1. Notify owner of discrepancies between existing conditions (including dimensions) and Drawings before proceeding with selective demolition.

2. Remove and dispose of metal flashing and coping, rubber membrane and asphalt underlayment, damaged clay roof tile, and damaged roof decking. Steel removed from roof to be recycled by owner, contractor to coordinate recycling of steel with owner.

3. Existing items to be removed and reinstalled include copper gutters/downspouts and french clay roof tiles and trim pieces. Carefully detach clay tiles in a manner to prevent damage. Contractor to provide 20% new french clay roof tile to replace damaged roof tiles.

4. Existing items to remain include wood tongue and groove decking, sheet decking and roof insulation. Inspect remaining roof substrates for damage and make repairs or replace as required.

Deck surfaces to be stable, clean, and dry prior to installation of new membrane.

5. Coordinate street closures with owner and city of Brookings. A minimum of 72 hour notice is reqd.

6. Coordiante sidewalk closures and building utility outages with owner in advance.

7. Create a tree protection zone, as shown on G001. Coordinate zone location and size with owner.

8. Contractor to locate the construction staging zone in the parking lot N of the museum as shown on G001. Staging zone not to impede sidewalks.

9. Provide protection to ensure safety of people in and around the museum and to prevent damage to adjacent buildings and facilities.

KEYNOTES

D01 French clay roof tile, ridge tiles, and eave tiles to be removed and salvaged for reinstallation.

D02 Metal flashing and coping, rubber membrane, and aphalt underlayment to be removed and disposed of.

D03 Copper gutters and downspouts to be removed and salvaged for reinstallation.

D04 Wood decking and roof insulation to remian; repair or replace damaged.

D05 Damaged clay tiles to be removed and disposed of. Provide min. 20% replacement decking, tiles, and insulation. New replacement tiles to match profile and color of exitsing tiles.

D06 Remove damaged or deteriorated fascia and soffit. Remove chipped and peeling paint. Repair fascia and soffit, prepare, and finish paint; typical.

A201

A202

A202

A01

A02

A02

A02 A02

A03

A201

50' - 0" 58' - 2" 36' - 10"

145' - 0"

6'

0"

6'

0"

48' - 10" 59' - 0" 37' - 2"

2'

2"

DSDS

DS

DS DS

DS

DS

DS

DSDS

A01 A01

A01

A14

A14

A14

A14 A14

A14

A14

A14A14

A14

A202

SP

A202

A202

6"

1' -0

6" / 1'-0"

6"

1' -0

6" / 1'-0"

6" / 1'-0" 6" / 1'-0"

4"

1' -0

4"

1' -0

6"

1' -0

6" / 1'-0"

6"

1' -0

6"

1' -0

6" / 1'-0"

A221

Sim

A221

Sim

A221

Sim

A221

Sim

A221

Sim

A221

Sim

A202

Sim

A221

Sim

A221

Sim

A221

Sim

18' - 6" 22' - 0" 18' - 6"

6"

1' -0

6" / 1'-0"

6"

1' -0

A202

Sim

A222

Sim

TYP.

4' - 0"

TY

P.

4'

0"

TYP.

2' - 0"

TYP.

2' - 0"

A15

A15

A15

A15

A16

A15

A16

A15

A16

A15

A16 A16

A15

A15

A16A16A15 A15 A15

TI

1/

4" /1

'-0

A18

A18

A18

A17

A17

A19

A19

A19

A17

0' 4' 8' 16' 32'

TI

1/ 4"

/1 '-0

TI

1/4"/1'-0"

TI

1/

4" /1

'-0

TI

1/4"/1'-0"

TI

1/4"/1'-0"

TI

1/4"/1'-0"

TI

1/

4" /1

'-0

4"

/1 '-0

TI

1/4"/1'-0"

TI

1/

4" /1

'-0

4"

/1 '-0

A20

A20

INDICATES ADHERED ICE AND WATER SHIELD 48" MIN. FROM EXT.

WALLS AND ALL VALLEYS,SEE KEY NOTE A15

INDICATES LOW SLOPE ADHERED MEMBRANE ROOF

INDICATES CLAY TILE ROOF

1/8" = 1'-0"1 Roof Plan

KEYNOTES

A01 Brick to be pointed and repaired by owner as required.

A02 Provide 26 gauge lead flashing at all roof valleys, sidewalls, parapets, and material transitions.

Extend minimum of 11" from centerline of valley; 4" minimum flash overlap.

A03 Provide treated 2x framing, 3/4" treated plywood decking, rubber ice and water shield, and counter flashing at new cricket location. Tie into ceramic tile roof A14 Provide concrete splash blocks at all downspout locations.

A15 Apply 48" wide 30 mil. adhered rubber membrane to deck for roof perimeter and 48" from sidewall locations and valleys.

A16 Apply 48" wide 30 mil. adhered ice and water shield to deck, centered on all valleys.

A17 Self-adhered sheet underlayment, polyethelene faced, min. 40-mil. thickness, slip resistent, polyethelene reinforced top surface, laminated to SBS modified asphalt adhesive, with replease paper backing.

A18 Self-adhered sheet underlayment bonded HDPE or polyethelene sheet.

A19 Salvaged French clay roof tile; provide 20% new and 30 new ridge tiles in unbroken bundles. New tile to match existing tile profile and color.

A20 Repair and replace damaged wood fascia and soffit; prepare and finish paint, typical.

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 1/8" = 1'-0"

4/ 3/

0:

:5

AM

A101

Roof Plan 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

ROOF PLAN GENERAL NOTES:

1. Notify owner of discrepancies between existing conditions (including dimensions) and Drawings before proceeding with re-roofing.

2. Coordinate street closures with owner and city of Brookings. A minimum of 72 hour notice is reqd.

3. Coordiante sidewalk closures and building utility outages with owner in advance.

4. Create a tree protection zone, as shown on G001. Coordinate zone location and size with owner.

5. Contractor to locate the construction staging zone in the parking lot N of the museum as shown on G001. Staging zone not to impede sidewalks.

6. Provide protection to ensure safety of people in and around the museum and to prevent damage to adjacent buildings and facilities.

7. Owner to tuckpoint brick as required on sidewalls and chimney. Contractor to notify owner of required repairs and coordinate masonry work with owner.

8. Existing items to be removed and reinstalled include copper gutters/downspouts and french clay roof tiles and trim pieces. Carefully detach clay tiles in a manner to prevent damage. Contractor to provide 20% new french clay roof tile to replace damaged roof tiles.

9. Existing items to remain include wood tongue and groove decking, sheet decking and roof insulation. Inspect remaining roof substrates for damage and make repairs or replace as required.

Deck surfaces to be stable, clean, and dry prior to installation of new membrane.

1st Floor 0' - 0"

UPPER EAVE

16' - 6"

FLAT ROOF

27' - 4"

A221

A222

Sim

LOW-SLOPE ROOF,

ADHERED RUBBER ROOFING

CLAY TILE

LEAD FLASHING

6"

1'-0"

COPPER GUTTERS

AND DOWNSPOUTS

CONCRETE SPLASH

BLOCKS

WOOD SOFFIT AND

FASCIA REPAIRS

1st Floor 0' - 0"

EAVE

12' - 0"

FLAT ROOF

27' - 4"

6"

1'-0"

6"

1'-0"

LOW-SLOPE ADHERED RUBBER ROOFINGLEAD FLASHING

CLAY TILE

COPPER GUTTERS

AND DOWNSPOUTS

CONCRETE SPLASH

BLOCKS

WOOD SOFFIT AND

FASCIA REPAIRS

A221

Sim

A222

Sim

3/16" = 1'-0"2 Building Section N/S

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 3/16" = 1'-0"

4/ 3/

0:

:5

AM

A201

Building Sections 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

3/16" = 1'-0"1 Building Section E/W

No. Description Date

LEAD FLASHING

OWNER TO

COORDINATE

MASONRY REPAIRS

PRIOR TO FLASHING

AND ROOFING

INSTALLATION

FULLY ADHERED MEMBRANE MEMBRANE

TERMINATION STRIP

COUNTER FLASHING

SEALANT

EXISTING DECK, INSULATION,

AND SHTG. TO REMAIN.

REPAIR/REPLACE AS REQD.

30 MIL. ADHERED RUBBER

MEMBRANE OVER SEAM OF

FLASHING

LEAD FLASHING

TREATED 2X CRICKET FRAMING

FULLY ADHERED

EPDM MEMBRANE;

RETURN AT

SIDEWALL

LEAD STEP FLASHING

TREATED SHEATHING

EXISTING DECKING TO REMAIN

CLAY TILE

OVERLAP

0' - 8"

EXISTING CHIMNEY

1'

0" M

IN

REPLACE:

- 60 MIL FULLY ADHERED EPDM MEMBRANE

- 1/2" HIGH DENSITY INSULATION

- TAPERED INSULATION (4" MINIMUM)

SEALANT

STAINLESS STEEL CLAMP

PREFABRICATED PIPE BOOT

SEALANT

EXISTING DECK, INSULATION, AND SHTG TO

REMAIN; REPAIR/REPLACE AS REQD.

2' - 0

" MIN.

REPLACE:

- 60 MIL FULLY ADHERED EPDM MEMBRANE

- 1/2" HIGH DENSITY INSULATION

- TAPERED INSULATION (4" MINIMUM)

REINFORCED

SECUREMENT STRIP

PLATE AND FASTENER

24 GA GALVANIZED FLAT METAL

TERMINATION BAR FASTENED 12" OC

SEALANT OVER FASTENER HEADS AND

BEHIND FLASHING MEMBRANE

1' - 0

" MIN.

TO REMAIN:

EXISTING ROOF

DECK, INSULATION

AND SHTG. TO

REMAIN; REPAIR AS

REQD.

2X TREATED

FRAMING

LEAD FLASHING

LEAD FLASHING

COPPER GUTTER

EXISTING T&G DECKING

FULLY ADHERED MEMBRANE

TREATED SHTG.

FULLY ADHERED MEMBRANE

M

IN

. 2 C

O U

R

SE

S M

EM

BR

AN

E

H T.

COUNTER FLASHING

COUNTER FLASHING

SOFFIT AND FASCIA

TO BE PREPPED

AND REPAINTED;

REPLACE AS REQD.

EXISTING BRICK CHIMNEY;

OWNER TO COORDINATE MASONRY REPAIRS

PRIOR TO FLASHING AND ROOFING INSTALLATION

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 1 1/2" = 1'-0"

4/ 3/

0:

:5

AM

A202

Building Sections 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

1 1/2" = 1'-0"4 Section at Sidewall

1 1/2" = 1'-0"5 Section at Cricket

1 1/2" = 1'-0"3 Section at Roof Penetration

1 1/2" = 1'-0"2 Detail at Base Flashing

1 1/2" = 1'-0"1 Section at Chimney

REPLACE:

- 60 MIL FULLY ADHERED EPDM MEMBRANE

- 1/2" HIGH DENSITY INSULATION

- TAPERED INSULATION (4" MINIMUM)

1/4" / 1'-0"

CLAY TILE MOLDED

FLANGE

LEAD FLASHING AND

CONTINUOUS CLIP

CLAY FRENCH STYLE

TILE

M

IN

0'

4"

ELASTOMERIC

SEALANT

TO REMAIN:

EXISTING 2-1/2" ROOF DECK,

INSULATION AND SHTG. TO REMAIN;

REPAIR/REPLACE AS REQD.

TO REMAIN:

EXISTING DECK, INSULATION,

AND SHTG; REPAIR AS REQD.

CLAY TILE NAILS

CLAY FRENCH STYLE

ROOFING TILE

SHEET

UNDERLAYMENT

FLASHING

MORTAR

OWNER TO COORDINATE MASONRY

REPAIRS PRIOR TO FLASHING AND

ROOFING INSTALLATION

0' - 5

" MIN.

HIP TILE

2x6 NAILER OR METAL RIDGE RISER

WIRE TIE TO SECURE BOOSTING TILES

BOOSTER END TILE

COVER FELT

NOTE:

NAILER BOARD SHOULD BE CUT

BACK 6" TO 8" TO MAKE ROOM FOR

BOOSTERS

SHEET

UNDERLAYMENT

HIP RAFTER

EXISTING 2-1/2" ROOF DECK,

INSULATION AND SHTG. TO

REMAIN; REPAIR AS REQD.

FRENCH

STYLE ROOF

TILE

TRIM TILE

CEMENT MORTAR

OR FLEXIBLE

FLASHING

ASTM D226 FELT

TO COVER NAILER

NOTE:

WRAPPING OF NAILER BOARD

IS OPTIONAL EXCEPT WITH

THE USE OF MORTAR

2x6 NAILER OR

METAL RIDGE

RISER

EXISTING 2-1/2" ROOF DECK,

INSULATION AND SHTG. TO

REMAIN; REPAIR AS REQD.

FLEXIBLE FLASHING

CONFORMED TO TILE MIN. 4-1/2"

STEP FLASHINGS COUNTER FLASHING

2" MIN. LAP

SHEET

UNDERLAYMENT

CORROSION

RESISTANT

FIREPLACE SADDLE

M

IN

0' - 6"

WOOD NAILER STRIP

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 3" = 1'-0"

4/ 3/

0:

:5

AM

A221

Details 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

3" = 1'-0"1 Roof Curb Detail

3" = 1'-0"4 Section at Head Wall

3" = 1'-0"2 Ridge and Hip End Booster 3" = 1'-0"3 Ridge and Hip Plate End Detail

3" = 1'-0"5 Chimney Flashing Detail

ROD AND SEALANT

COUNTER FLASHING

LEAD FLASHING

FULLY ADHERED MEMBRANE

OWNER TO TUCKPOINT SIDEWALLS AS REQD.

COORDINATE MASONRY WORK WITH OWNER

TO REMAIN:

2-1/2" ROOF DECKING,

INSULATION, AND 3/4" SHTG.

TO REMAIN; REPAIR/REPLACE

AS REQD.

CLAY FRENCH STYLE ROOFING TILE

HEADLAP

0' - 3

" MIN.

CLAY TILE NAILS

EAVE CANT STRIP

COPPER FLASHING

AND DRIP EDGE

2X WOOD FASCIA

BOARD REPLACE

/REPAIR AS REQD.

TO REMAIN:

2-1/2" ROOF DECKING,

INSULATION, AND 3/4" SHTG.

TO REMAIN; REPAIR/REPLACE

AS REQD.

OVERHANG3/4" MIN.-

0' - 2

" MAX.

SHEET UNDERLAYMENT

48" WIDE 30 MIL. SELF

ADHERING SHEET

UNDERLAYMENT MEMBRANE,

APPLIED AROUND ENTIRE

PERIMETER OF ROOF AND AT

SIDEWALL LOCATIONS

EXISTING 2X6

RAFTER

EXTENSIONS

EXISTING 1"X24"

FREEZE BOARD

EXISTING

RAFTERS

COPPER

GUTTERS,

LOCATE 1-1/2"

BELOW SLOPE

LINE

30 MIL. MEMBRANE

4' - 0

CLAY FRENCH STYLE

ROOF TILE

SHEET

UNDERLAYMENT

HIP TILE

CEMENT MORTAR

FASTENERS

SELF ADHERED MEMBRANE

PROPER HT. FOUNDATION GRADE

RIDGE STRINGER

TO REMAIN:

2-1/2" ROOF DECKING,

INSULATION, AND 3/4" SHTG.

TO REMAIN; REPAIR/REPLACE

AS REQD.

FRENCH

CUT VALLEY TILE

AT TOP OF VALLEY

0' - 6" MIN. OPENING

COPPER CLEAT AT

8"-24" OC BEND OVER

FASTENER

COPPER OR LEAD VALLEY FLASHING

SELF-ADHERED

MEMBRANE

ICE AND WATER SHIELD

RUBBER ROOFING MEMBRANE

TO REMAIN:

2-1/2" ROOF DECKING, INSULATION,

AND 3/4" SHTG. TO REMAIN;

REPAIR/REPLACE AS REQD.

CLAY TILE NAILS

30 MIL. SELF ADHERED SHEET

UNDERLAYMENT, 48"W

FRENCH STYLE ROOF TILES

0'

1"

FRENCH DETACHED RAKE

FASCIA

TO REMAIN:

2-1/2" ROOF DECKING,

INSULATION, AND 3/4" SHTG.

TO REMAIN; REPAIR/REPLACE

AS REQD.

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by 3" = 1'-0"

4/ 3/

0:

:5

AM

A222

Details 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

3" = 1'-0"2 Section at Sidewall

3" = 1'-0"1 Eave Detail 3" = 1'-0"4 Hip Section

3" = 1'-0"5 Section at Valley

3" = 1'-0"3 Rake Detail

RIDGE

VALLEY FLASHING

RIDGE VENT

RAKE FLASHING (LEFT)

GABLE END

RAKE FLASHING (RIGHT)

SIDE WALL FLASHING

EAVE

HEAD WALL FLASHING

DORMER

DRIP EAVE FLASHING

GUTTER

DOWNSPOUT SPLASH BLOCK

SOFFIT

PLUMBING VENT

FLASHING (SOIL

PIPE STACK)

HIP

FIELD OF ROOF

ROOF VENT FLASHING

CHIMNEY FLASHING

WOOD ROOF DECK

SHEET UNDERLAYMENT

HEAD LAP

0' - 2" M

IN.

END LAP6" M

IN.

COPPER FLASHING WITH DRIP EDGE

SECURE METAL DRIP EDGES WITH COPPER NAILS

SPACED AT 10" O.C. MAX.

EAVE METAL DRIP EDGE INSTALLED BEFORE

UNDERLAYMENT

END LAP0' - 8

HEAD LAP

0' - 2"

NAILS AT 3" O.C.

(STAGGERED)

MASTIC

(OPTIONAL)

BLIND NAIL

AT 9" O.C.

EXPOSE NAIL

AT 12" O.C.

0' - 3"

SHEET UNDERLAYMENT

VALLEY FLASHING

(EXTEND BEYOND ROOF EDGE)

EAVE COPPER DRIP EDGE

3' - 0"

1" V-CRIMP

Scale

Project number Date

Checked by

Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010

Drawn by As indicated

4/ 3/

0:

:5

AM

A223

Details 22-109330

Agricultural Heritage Museum

Historic Roof Replacement 04/03/2024

CS

JM

No. Description Date

3" = 1'-0"1 Roof Area Flashing Identification 3/4" = 1'-0"2 Felt Underlayment

3/4" = 1'-0"3 Valley Underlayment

G001 - Title Sheet
D101 - Roof Demolition
A101 - Roof Plan
A201 - Building Sections
A202 - Building Sections
A221 - Details
A222 - Details
A223 - Details

File details come from the government source that posted it. Updated .