SDSU Agricultural Heritage Museum Historic Roof Repairs Drawings.pdf
PDF 915 KB Posted
- Solicitation number
- 24IFB10715
- Issued by
- Brown County, South Dakota
About this file
This document is a government file related to a state and local contract opportunity for the historic roof replacement project at the South Dakota Agricultural Heritage Museum on the South Dakota State University campus in Brookings, South Dakota. The project involves the removal, salvage, and reinstallation of approximately 12,000 square feet of existing French clay roofing tiles, ridge, and hip caps, as well as the removal and disposal of roofing membrane, asphalt underlayment, miscellaneous rough carpentry, and deteriorated decorative wood carpentry. New construction will include roofing membrane, underlayment, ice & water shield, copper flashing, copper gutters, 20% replacement clay roofing tiles, rough carpentry, ornamental carpentry, sealants, and exterior paint. The estimated project cost is under $800,000. A pre-bid meeting is scheduled for April 18, 2024, and bids are due by April 25, 2024.
The contract will be a single prime contract. Pricing terms, set-asides, funding requirements and sources, and other salient information are not provided in the document. The current incumbent, if any, is not specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
11TH STREET
M
ED
AR
Y
AV
EN
U E
CONSTRUCTION
STAGING ZONE
TREE
PROTECTION
ZONE
RAMP
POTENTIAL TRAFFIC
CONTROL ZONE
Not to Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
AG HERITAGE MUSEUM
HISTORIC ROOF REPLACEMENT
SOUTH DAKOTA STATE UNIVERSITY
BUILDING #: 0601
WO# 22-109330
SCOPE OF WORK SUMMARY:
PROJECT CONSISTS OF THE REMOVAL, SALVAGE, AND REINSTALLATION OF
APPROXIMATELY 12,000 SQUARE FEET OF EXISTING FRENCH CLAY ROOFING TILES,
RIDGE, AND HIP CAPS. THE PROJECT ALSO INCLUDES THE REMOVAL AND DISPOSAL
OF ROOFING MEMBRANE, ASPHALT UNDERLAYMENT, MISCELLANEOUS ROUGH
CARPENTRY, AND DETERIORATED DECORATIVE WOOD CARPENTRY. NEW
CONSTRUCTION WILL INCLUDE ROOFING MEMBRANE, UNDERLAYMENT, ICE & WATER
SHIELD, COPPER FLASHING, COPPER GUTTERS, 20% REPLACEMENT CLAY ROOFING
TILES, ROUGH CARPENTRY, ORNAMENTAL CARPENTRY, SEALANTS, AND EXTERIOR
PAINT. COPPER DOWNSPOUTS ARE TO BE SALVAGED AND REINSTALLED. INSPECT
THE EXISTING TONGUE & GROOVE ROOF DECKING AND SHEET DECKING FOR
DAMAGE AND IRREGULARITIES, REPAIR AS REQUIRED TO MAINTAIN A STABLE
SUBSTRATE FOR THE ROOF ASSEMBLY INSTALLATION.
UNIT PRICES:
PROJECT CONTACTS:
PROJECT MANAGER: CHRISTOPHER GROSS PHONE: (605) 688-6251
PROJECT OWNER: GWEN MCCAUSLAND PHONE: (605) 688-4581
ARCHITECT: JONATHAN MEENDERING PHONE: (605) 688-4975
LOCATION MAP:
A101
SIM
A101
SIM
A101
1 1
SYMBOLS:
SHEET INDEX:
REVISION TAG
WINDOW TAG
DOOR TAG
WALL TAG
KEYNOTE
1t
1i
A01
ROOM NAME
150 SF
ROOM TAG
VIEW TITLE
ELEVATION TAG
CENTERLINE
1 VIEW NAME
SCALE: 1/8"=1'-0"
CALLOUT
INTERIOR ELEVATION
SECTION TAG
ABBREVIATIONS:
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATELY
BSMT BASEMENT
BTTM BOTTOM OF
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST J CONSTRUCTION JOINT
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
DBL DOUBLE
DEMO DEMOLISH
DIA DIAMETER
DIMS DIMENSIONS
DN DOWN
DTL DETAIL
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EPDM PROPYLENE DIENE ROOFING
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FLR FLOOR
FO FACE OF
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GWB GYPSUM WALL BOARD
HC HOLLOW CORE
HM HOLLOW METAL
HVAC HEATING VENTILATION & AIR CONDITIONING
INSUL INSULATION
INT INTERIOR
LAV LAVATORY
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MTL METAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
OC ON CENTER
PCC PRE-CAST CONCRETE
PLUMB PLUMBING
PNT PAINT/PAINTED
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
R RADIUS
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCED
REQD REQUIRED
RM ROOM
SF SQUARE FOOT
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFIED OR SPECIFICATION
SPK SPRINKLER
SQ SQUARE
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION COEFFICIENT
STL STEEL
STRUCT STRUCTURAL
T&G TONGUE AND GROOVE
TI TAPERED INSULATION
TO TOP OF
T/D TELEPHONE AND DATA
TELE TELEPHONE
TOS TOP OF STRUCTURE
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
VP VISION PANEL
W/ WITH
WC WATER CLOSET
WD WOOD
Drawn by
1.
2.
3.
4.
5.
6.
TONGUE AND GROOVE ROOF DECKING
COPPER FLASHING AND COPING
EXTERIOR FINISH CARPENTRY
EXTERIOR PAINT
THERMAL INSULATION
WOOD ROOF DECKING, SHEET.
4/ 3/
0:
:5
AM
G001
Title Sheet 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
SOUTH DAKOTA AGRICULTURAL HERITAGE MUSEUM
977 11TH STREET
BROOKINGS SD 57007
G001 Title Sheet G002 Historic Preservation Review D101 Roof Demolition A101 Roof Plan A201 Building Sections A202 Building Sections A221 Details A222 Details A223 Details
No. Description Date
D01D02
D03
D03
50' - 0" 58' - 2" 36' - 10"
6'
0"
145' - 0"
48' - 10" 59' - 0" 37' - 2"
18' - 6" 22' - 0" 18' - 6"
≈270 SF
≈476 SF
≈1376 SF
6"
1' -0
6" / 1'-0"
6"
1' -0
6" / 1'-0"
6"
1' -0
6"
1' -0
6" / 1'-0"
6"
1' -0
4"
1' -0
4"
1' -0
6" / 1'-0" 6" / 1'-0"
6" / 1'-0"
6'
0"
6"
1' -0
6" / 1'-0"
D01
D01
D01
D02
D02
D02
D03
D04
D04
D04
D04
D04
D04
D04
D05
0' 4' 8' 16' 32'
2'
2"
D06
INDICATES EXISTING LOW SLOPE ADHERED MEMBRANE ROOF
INDICATES EXISTING CLAY TILE ROOF
1/8" = 1'-0"1 Roof Demolition
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 1/8" = 1'-0"
4/ 3/
0:
:5
AM
D101
Roof Demolition 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
DEMOLITION GENERAL NOTES:
1. Notify owner of discrepancies between existing conditions (including dimensions) and Drawings before proceeding with selective demolition.
2. Remove and dispose of metal flashing and coping, rubber membrane and asphalt underlayment, damaged clay roof tile, and damaged roof decking. Steel removed from roof to be recycled by owner, contractor to coordinate recycling of steel with owner.
3. Existing items to be removed and reinstalled include copper gutters/downspouts and french clay roof tiles and trim pieces. Carefully detach clay tiles in a manner to prevent damage. Contractor to provide 20% new french clay roof tile to replace damaged roof tiles.
4. Existing items to remain include wood tongue and groove decking, sheet decking and roof insulation. Inspect remaining roof substrates for damage and make repairs or replace as required.
Deck surfaces to be stable, clean, and dry prior to installation of new membrane.
5. Coordinate street closures with owner and city of Brookings. A minimum of 72 hour notice is reqd.
6. Coordiante sidewalk closures and building utility outages with owner in advance.
7. Create a tree protection zone, as shown on G001. Coordinate zone location and size with owner.
8. Contractor to locate the construction staging zone in the parking lot N of the museum as shown on G001. Staging zone not to impede sidewalks.
9. Provide protection to ensure safety of people in and around the museum and to prevent damage to adjacent buildings and facilities.
KEYNOTES
D01 French clay roof tile, ridge tiles, and eave tiles to be removed and salvaged for reinstallation.
D02 Metal flashing and coping, rubber membrane, and aphalt underlayment to be removed and disposed of.
D03 Copper gutters and downspouts to be removed and salvaged for reinstallation.
D04 Wood decking and roof insulation to remian; repair or replace damaged.
D05 Damaged clay tiles to be removed and disposed of. Provide min. 20% replacement decking, tiles, and insulation. New replacement tiles to match profile and color of exitsing tiles.
D06 Remove damaged or deteriorated fascia and soffit. Remove chipped and peeling paint. Repair fascia and soffit, prepare, and finish paint; typical.
A201
A202
A202
A01
A02
A02
A02 A02
A03
A201
50' - 0" 58' - 2" 36' - 10"
145' - 0"
6'
0"
6'
0"
48' - 10" 59' - 0" 37' - 2"
2'
2"
DSDS
DS
DS DS
DS
DS
DS
DSDS
A01 A01
A01
A14
A14
A14
A14 A14
A14
A14
A14A14
A14
A202
SP
A202
A202
6"
1' -0
6" / 1'-0"
6"
1' -0
6" / 1'-0"
6" / 1'-0" 6" / 1'-0"
4"
1' -0
4"
1' -0
6"
1' -0
6" / 1'-0"
6"
1' -0
6"
1' -0
6" / 1'-0"
A221
Sim
A221
Sim
A221
Sim
A221
Sim
A221
Sim
A221
Sim
A202
Sim
A221
Sim
A221
Sim
A221
Sim
18' - 6" 22' - 0" 18' - 6"
6"
1' -0
6" / 1'-0"
6"
1' -0
A202
Sim
A222
Sim
TYP.
4' - 0"
TY
P.
4'
0"
TYP.
2' - 0"
TYP.
2' - 0"
A15
A15
A15
A15
A16
A15
A16
A15
A16
A15
A16 A16
A15
A15
A16A16A15 A15 A15
TI
1/
4" /1
'-0
A18
A18
A18
A17
A17
A19
A19
A19
A17
0' 4' 8' 16' 32'
TI
1/ 4"
/1 '-0
TI
1/4"/1'-0"
TI
1/
4" /1
'-0
TI
1/4"/1'-0"
TI
1/4"/1'-0"
TI
1/4"/1'-0"
TI
1/
4" /1
'-0
4"
/1 '-0
TI
1/4"/1'-0"
TI
1/
4" /1
'-0
4"
/1 '-0
A20
A20
INDICATES ADHERED ICE AND WATER SHIELD 48" MIN. FROM EXT.
WALLS AND ALL VALLEYS,SEE KEY NOTE A15
INDICATES LOW SLOPE ADHERED MEMBRANE ROOF
INDICATES CLAY TILE ROOF
1/8" = 1'-0"1 Roof Plan
KEYNOTES
A01 Brick to be pointed and repaired by owner as required.
A02 Provide 26 gauge lead flashing at all roof valleys, sidewalls, parapets, and material transitions.
Extend minimum of 11" from centerline of valley; 4" minimum flash overlap.
A03 Provide treated 2x framing, 3/4" treated plywood decking, rubber ice and water shield, and counter flashing at new cricket location. Tie into ceramic tile roof A14 Provide concrete splash blocks at all downspout locations.
A15 Apply 48" wide 30 mil. adhered rubber membrane to deck for roof perimeter and 48" from sidewall locations and valleys.
A16 Apply 48" wide 30 mil. adhered ice and water shield to deck, centered on all valleys.
A17 Self-adhered sheet underlayment, polyethelene faced, min. 40-mil. thickness, slip resistent, polyethelene reinforced top surface, laminated to SBS modified asphalt adhesive, with replease paper backing.
A18 Self-adhered sheet underlayment bonded HDPE or polyethelene sheet.
A19 Salvaged French clay roof tile; provide 20% new and 30 new ridge tiles in unbroken bundles. New tile to match existing tile profile and color.
A20 Repair and replace damaged wood fascia and soffit; prepare and finish paint, typical.
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 1/8" = 1'-0"
4/ 3/
0:
:5
AM
A101
Roof Plan 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
ROOF PLAN GENERAL NOTES:
1. Notify owner of discrepancies between existing conditions (including dimensions) and Drawings before proceeding with re-roofing.
2. Coordinate street closures with owner and city of Brookings. A minimum of 72 hour notice is reqd.
3. Coordiante sidewalk closures and building utility outages with owner in advance.
4. Create a tree protection zone, as shown on G001. Coordinate zone location and size with owner.
5. Contractor to locate the construction staging zone in the parking lot N of the museum as shown on G001. Staging zone not to impede sidewalks.
6. Provide protection to ensure safety of people in and around the museum and to prevent damage to adjacent buildings and facilities.
7. Owner to tuckpoint brick as required on sidewalls and chimney. Contractor to notify owner of required repairs and coordinate masonry work with owner.
8. Existing items to be removed and reinstalled include copper gutters/downspouts and french clay roof tiles and trim pieces. Carefully detach clay tiles in a manner to prevent damage. Contractor to provide 20% new french clay roof tile to replace damaged roof tiles.
9. Existing items to remain include wood tongue and groove decking, sheet decking and roof insulation. Inspect remaining roof substrates for damage and make repairs or replace as required.
Deck surfaces to be stable, clean, and dry prior to installation of new membrane.
1st Floor 0' - 0"
UPPER EAVE
16' - 6"
FLAT ROOF
27' - 4"
A221
A222
Sim
LOW-SLOPE ROOF,
ADHERED RUBBER ROOFING
CLAY TILE
LEAD FLASHING
6"
1'-0"
COPPER GUTTERS
AND DOWNSPOUTS
CONCRETE SPLASH
BLOCKS
WOOD SOFFIT AND
FASCIA REPAIRS
1st Floor 0' - 0"
EAVE
12' - 0"
FLAT ROOF
27' - 4"
6"
1'-0"
6"
1'-0"
LOW-SLOPE ADHERED RUBBER ROOFINGLEAD FLASHING
CLAY TILE
COPPER GUTTERS
AND DOWNSPOUTS
CONCRETE SPLASH
BLOCKS
WOOD SOFFIT AND
FASCIA REPAIRS
A221
Sim
A222
Sim
3/16" = 1'-0"2 Building Section N/S
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 3/16" = 1'-0"
4/ 3/
0:
:5
AM
A201
Building Sections 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
3/16" = 1'-0"1 Building Section E/W
No. Description Date
LEAD FLASHING
OWNER TO
COORDINATE
MASONRY REPAIRS
PRIOR TO FLASHING
AND ROOFING
INSTALLATION
FULLY ADHERED MEMBRANE MEMBRANE
TERMINATION STRIP
COUNTER FLASHING
SEALANT
EXISTING DECK, INSULATION,
AND SHTG. TO REMAIN.
REPAIR/REPLACE AS REQD.
30 MIL. ADHERED RUBBER
MEMBRANE OVER SEAM OF
FLASHING
LEAD FLASHING
TREATED 2X CRICKET FRAMING
FULLY ADHERED
EPDM MEMBRANE;
RETURN AT
SIDEWALL
LEAD STEP FLASHING
TREATED SHEATHING
EXISTING DECKING TO REMAIN
CLAY TILE
OVERLAP
0' - 8"
EXISTING CHIMNEY
1'
0" M
IN
REPLACE:
- 60 MIL FULLY ADHERED EPDM MEMBRANE
- 1/2" HIGH DENSITY INSULATION
- TAPERED INSULATION (4" MINIMUM)
SEALANT
STAINLESS STEEL CLAMP
PREFABRICATED PIPE BOOT
SEALANT
EXISTING DECK, INSULATION, AND SHTG TO
REMAIN; REPAIR/REPLACE AS REQD.
2' - 0
" MIN.
REPLACE:
- 60 MIL FULLY ADHERED EPDM MEMBRANE
- 1/2" HIGH DENSITY INSULATION
- TAPERED INSULATION (4" MINIMUM)
REINFORCED
SECUREMENT STRIP
PLATE AND FASTENER
24 GA GALVANIZED FLAT METAL
TERMINATION BAR FASTENED 12" OC
SEALANT OVER FASTENER HEADS AND
BEHIND FLASHING MEMBRANE
1' - 0
" MIN.
TO REMAIN:
EXISTING ROOF
DECK, INSULATION
AND SHTG. TO
REMAIN; REPAIR AS
REQD.
2X TREATED
FRAMING
LEAD FLASHING
LEAD FLASHING
COPPER GUTTER
EXISTING T&G DECKING
FULLY ADHERED MEMBRANE
TREATED SHTG.
FULLY ADHERED MEMBRANE
M
IN
. 2 C
O U
R
SE
S M
EM
BR
AN
E
H T.
COUNTER FLASHING
COUNTER FLASHING
SOFFIT AND FASCIA
TO BE PREPPED
AND REPAINTED;
REPLACE AS REQD.
EXISTING BRICK CHIMNEY;
OWNER TO COORDINATE MASONRY REPAIRS
PRIOR TO FLASHING AND ROOFING INSTALLATION
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 1 1/2" = 1'-0"
4/ 3/
0:
:5
AM
A202
Building Sections 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
1 1/2" = 1'-0"4 Section at Sidewall
1 1/2" = 1'-0"5 Section at Cricket
1 1/2" = 1'-0"3 Section at Roof Penetration
1 1/2" = 1'-0"2 Detail at Base Flashing
1 1/2" = 1'-0"1 Section at Chimney
REPLACE:
- 60 MIL FULLY ADHERED EPDM MEMBRANE
- 1/2" HIGH DENSITY INSULATION
- TAPERED INSULATION (4" MINIMUM)
1/4" / 1'-0"
CLAY TILE MOLDED
FLANGE
LEAD FLASHING AND
CONTINUOUS CLIP
CLAY FRENCH STYLE
TILE
M
IN
0'
4"
ELASTOMERIC
SEALANT
TO REMAIN:
EXISTING 2-1/2" ROOF DECK,
INSULATION AND SHTG. TO REMAIN;
REPAIR/REPLACE AS REQD.
TO REMAIN:
EXISTING DECK, INSULATION,
AND SHTG; REPAIR AS REQD.
CLAY TILE NAILS
CLAY FRENCH STYLE
ROOFING TILE
SHEET
UNDERLAYMENT
FLASHING
MORTAR
OWNER TO COORDINATE MASONRY
REPAIRS PRIOR TO FLASHING AND
ROOFING INSTALLATION
0' - 5
" MIN.
HIP TILE
2x6 NAILER OR METAL RIDGE RISER
WIRE TIE TO SECURE BOOSTING TILES
BOOSTER END TILE
COVER FELT
NOTE:
NAILER BOARD SHOULD BE CUT
BACK 6" TO 8" TO MAKE ROOM FOR
BOOSTERS
SHEET
UNDERLAYMENT
HIP RAFTER
EXISTING 2-1/2" ROOF DECK,
INSULATION AND SHTG. TO
REMAIN; REPAIR AS REQD.
FRENCH
STYLE ROOF
TILE
TRIM TILE
CEMENT MORTAR
OR FLEXIBLE
FLASHING
ASTM D226 FELT
TO COVER NAILER
NOTE:
WRAPPING OF NAILER BOARD
IS OPTIONAL EXCEPT WITH
THE USE OF MORTAR
2x6 NAILER OR
METAL RIDGE
RISER
EXISTING 2-1/2" ROOF DECK,
INSULATION AND SHTG. TO
REMAIN; REPAIR AS REQD.
FLEXIBLE FLASHING
CONFORMED TO TILE MIN. 4-1/2"
STEP FLASHINGS COUNTER FLASHING
2" MIN. LAP
SHEET
UNDERLAYMENT
CORROSION
RESISTANT
FIREPLACE SADDLE
M
IN
0' - 6"
WOOD NAILER STRIP
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 3" = 1'-0"
4/ 3/
0:
:5
AM
A221
Details 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
3" = 1'-0"1 Roof Curb Detail
3" = 1'-0"4 Section at Head Wall
3" = 1'-0"2 Ridge and Hip End Booster 3" = 1'-0"3 Ridge and Hip Plate End Detail
3" = 1'-0"5 Chimney Flashing Detail
ROD AND SEALANT
COUNTER FLASHING
LEAD FLASHING
FULLY ADHERED MEMBRANE
OWNER TO TUCKPOINT SIDEWALLS AS REQD.
COORDINATE MASONRY WORK WITH OWNER
TO REMAIN:
2-1/2" ROOF DECKING,
INSULATION, AND 3/4" SHTG.
TO REMAIN; REPAIR/REPLACE
AS REQD.
CLAY FRENCH STYLE ROOFING TILE
HEADLAP
0' - 3
" MIN.
CLAY TILE NAILS
EAVE CANT STRIP
COPPER FLASHING
AND DRIP EDGE
2X WOOD FASCIA
BOARD REPLACE
/REPAIR AS REQD.
TO REMAIN:
2-1/2" ROOF DECKING,
INSULATION, AND 3/4" SHTG.
TO REMAIN; REPAIR/REPLACE
AS REQD.
OVERHANG3/4" MIN.-
0' - 2
" MAX.
SHEET UNDERLAYMENT
48" WIDE 30 MIL. SELF
ADHERING SHEET
UNDERLAYMENT MEMBRANE,
APPLIED AROUND ENTIRE
PERIMETER OF ROOF AND AT
SIDEWALL LOCATIONS
EXISTING 2X6
RAFTER
EXTENSIONS
EXISTING 1"X24"
FREEZE BOARD
EXISTING
RAFTERS
COPPER
GUTTERS,
LOCATE 1-1/2"
BELOW SLOPE
LINE
30 MIL. MEMBRANE
4' - 0
CLAY FRENCH STYLE
ROOF TILE
SHEET
UNDERLAYMENT
HIP TILE
CEMENT MORTAR
FASTENERS
SELF ADHERED MEMBRANE
PROPER HT. FOUNDATION GRADE
RIDGE STRINGER
TO REMAIN:
2-1/2" ROOF DECKING,
INSULATION, AND 3/4" SHTG.
TO REMAIN; REPAIR/REPLACE
AS REQD.
FRENCH
CUT VALLEY TILE
AT TOP OF VALLEY
0' - 6" MIN. OPENING
COPPER CLEAT AT
8"-24" OC BEND OVER
FASTENER
COPPER OR LEAD VALLEY FLASHING
SELF-ADHERED
MEMBRANE
ICE AND WATER SHIELD
RUBBER ROOFING MEMBRANE
TO REMAIN:
2-1/2" ROOF DECKING, INSULATION,
AND 3/4" SHTG. TO REMAIN;
REPAIR/REPLACE AS REQD.
CLAY TILE NAILS
30 MIL. SELF ADHERED SHEET
UNDERLAYMENT, 48"W
FRENCH STYLE ROOF TILES
0'
1"
FRENCH DETACHED RAKE
FASCIA
TO REMAIN:
2-1/2" ROOF DECKING,
INSULATION, AND 3/4" SHTG.
TO REMAIN; REPAIR/REPLACE
AS REQD.
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by 3" = 1'-0"
4/ 3/
0:
:5
AM
A222
Details 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
3" = 1'-0"2 Section at Sidewall
3" = 1'-0"1 Eave Detail 3" = 1'-0"4 Hip Section
3" = 1'-0"5 Section at Valley
3" = 1'-0"3 Rake Detail
RIDGE
VALLEY FLASHING
RIDGE VENT
RAKE FLASHING (LEFT)
GABLE END
RAKE FLASHING (RIGHT)
SIDE WALL FLASHING
EAVE
HEAD WALL FLASHING
DORMER
DRIP EAVE FLASHING
GUTTER
DOWNSPOUT SPLASH BLOCK
SOFFIT
PLUMBING VENT
FLASHING (SOIL
PIPE STACK)
HIP
FIELD OF ROOF
ROOF VENT FLASHING
CHIMNEY FLASHING
WOOD ROOF DECK
SHEET UNDERLAYMENT
HEAD LAP
0' - 2" M
IN.
END LAP6" M
IN.
COPPER FLASHING WITH DRIP EDGE
SECURE METAL DRIP EDGES WITH COPPER NAILS
SPACED AT 10" O.C. MAX.
EAVE METAL DRIP EDGE INSTALLED BEFORE
UNDERLAYMENT
END LAP0' - 8
HEAD LAP
0' - 2"
NAILS AT 3" O.C.
(STAGGERED)
MASTIC
(OPTIONAL)
BLIND NAIL
AT 9" O.C.
EXPOSE NAIL
AT 12" O.C.
0' - 3"
SHEET UNDERLAYMENT
VALLEY FLASHING
(EXTEND BEYOND ROOF EDGE)
EAVE COPPER DRIP EDGE
3' - 0"
1" V-CRIMP
Scale
Project number Date
Checked by
Facilities and Services Administration 304, Box 2201 South Dakota State University Brookings, SD 57007-1698 Phone 605-688-4136 Fax: 605-688-4010
Drawn by As indicated
4/ 3/
0:
:5
AM
A223
Details 22-109330
Agricultural Heritage Museum
Historic Roof Replacement 04/03/2024
CS
JM
No. Description Date
3" = 1'-0"1 Roof Area Flashing Identification 3/4" = 1'-0"2 Felt Underlayment
3/4" = 1'-0"3 Valley Underlayment
| G001 - Title Sheet |
| D101 - Roof Demolition |
| A101 - Roof Plan |
| A201 - Building Sections |
| A202 - Building Sections |
| A221 - Details |
| A222 - Details |
| A223 - Details |
File details come from the government source that posted it. Updated .