SCRRF_Enclosed_Flare_Station_Installation_Project_-_IFB_Plans.pdf
PDF 31 MB Posted
- Solicitation number
- IFB No. PW-0269
- Issued by
- Santa Cruz County, San Francisco City, California
About this file
This is an Invitation for Bids (IFB No. PW-0269) document package prepared by the City of Santa Cruz Public Works Department for the Santa Cruz Resource Recovery Facility Enclosed Flare Station Installation Project. The project involves the design, construction, and installation of a low-nitrogen oxide (NOx) enclosed flare station at the City's Resource Recovery Facility located at 605 Dimeo Lane, Santa Cruz, California. The scope of work includes construction of approximately 3,600 square feet of flare station infrastructure, installation of approximately 200 linear feet of landfill gas header pipe, condensate management and air pipelines, a 92-inch outer diameter by 420-foot tall flare stack with combustion air blower systems and gas handling equipment, trenching, electrical work, concrete foundations, structural steel installation, and a six-foot-high chain link fence with access gates. The mandatory pre-bid meeting is scheduled for February 23, 2026, at 10:00 a.m. at the project site. Questions and clarifications must be submitted by February 27, 2026, at 5:00 p.m. Sealed bids are due by March 10, 2026, at 2:00 p.m. local time and will be publicly opened and read at the Santa Cruz Public Works Department, 809 Center Street, Room 201. The project must be completed within 90 working days from the Notice to Proceed.
The engineer's estimate for this project is $635,000, and bidders must provide firm-fixed pricing with no escalation. Bid security of 10 percent of the proposal amount must accompany each bid submission. At contract award, the successful bidder must provide a performance bond equal to 100 percent of the contract price, a payment bond of 50 percent of the contract price, and a maintenance bond equal to 10 percent of the contract price, with the maintenance bond remaining in force for one year after official acceptance. Successful bidders must submit a minimum of three client references demonstrating relevant experience within the past five years, comply with prevailing wage requirements, maintain current California Department of Industrial Relations registration, and provide proof of insurance including Professional Liability, Commercial General Liability, Auto Liability, and Workers' Compensation coverage with minimum limits of $2,000,000 per occurrence for general liability and $1,000,000 for automobile liability. Liquidated damages of $1,000 per calendar day apply for failure to meet the 90 working day deadline. The solicitation does not identify specific set-aside designations for disadvantaged enterprises. All contractors must comply with the City's Living Wage Ordinance and prevailing wage requirements. The City reserves the right to reject any and all bids and will award the contract to the lowest responsible and responsive bidder.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_T
IT
LE
S
H
EE
T.
dw g L ay ou t:
G
-0
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 6
:1 9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
21700 COPLEY DRIVE, SUITE 200
DIAMOND BAR, CA 91765
TEL: (909) 860-7777
FAX: (909)860-8017
LOCATION MAP
RECOVERY
FACILITY
SANTA CRUZ
RESOURCE
PROJECT MANAGER
DEPUTY DIRECTOR
SENIOR ENGINEER
RECOMMENDED:
APPROVED:
DATE
DATE
ACCEPTED:
CITY OF SANTA CRUZ
PUBLIC WORKS DEPARTMENT
809 CENTER STREET, ROOM 201
SANTA CRUZ, CA 95060
PAUL J. STOUT, P.E.
TETRA TECH
UNDERGROUND SERVICE ALERT
Call: TOLL FREED
AC
LL
YE OU
RFO
BE
GI
OWNER: CIVIL ENGINEER:
CITY OF SANTA CRUZ RESOURCE RECOVERY FACILITY
605 DIMEO LANE
SANTA CRUZ, CA 95060
COORDINATES SHOWN ARE BASED ON
NAD27, CALIFORNIA ZONE III COORDINATE
SYSTEM
ELEVATIONS WAS REFERENCE TO
CONTROL PROVIDED BY THE CITY OF
SANTA CRUZ.
BASIS OF BEARINGS:
AT LEAST TWO DAYS
BEFORE YOU DIG
SITE ADDRESS:
VENTURA
MONO
SAN BERNARDINO
INYO
TULARE
LOS
ANGELES
KERN
IMPERIAL
RIVERSIDE
ORANGE
SAN DIEGO
LASSEN
MODOC
BUTTE SIERRA
PLUMAS
SISKIYOU
TRINITY
TEHAMA
GLENN
MENDOCINO
SHASTA
ALPINE
SUTTER
M
EN
TO
SA
CR
A-
AMADOR
EL DORADO
PLACER
MARIPOSA
MADERACLARA
STANISLAUS
CALA
VERAS
TUOLUMNE
JO
AQUINSAN
COLUSA
LAKE
NAPASONOMA
SAN MATEO
SAN FRANCISCO
MARIN
CONTRA
SOLANO
SANTA
ALAMEDA
COSTA
YOLO
YUBA NEVADA
HUMBOLDT
DEL NORTE
FRESNO
KINGS
BENITO
MONTEREY
SAN
SANTA
OBISPO
BARBARA
LUIS
SAN
PROJECT LOCATION
MERCED
VICINITY MAP
SANTA CRUZ
CITY OF SANTA CRUZ
PUBLIC WORKS DEPARTMENT
RESOURCE RECOVERY FACILITY (RRF)
SANTA CRUZ, CALIFORNIA
SANTA CRUZ RRF ENCLOSED FLARE STATION
INSTALLATION PROJECT
COVER SHEET
NOT TO SCALE
NOT TO SCALE
SHEET INDEX
SHEET NUMBER DESCRIPTION
G-002
C-100 EXISTING SITE PLAN
M-101 CONSTRUCTION SITE PLAN
M-102 UTILITY SITE PLAN
M-301 FLARE STATION SECTIONS
M-501 TYPICAL DETAILS
SYMBOLS AND ABBREVIATIONS
D-601 PIPE INSTRUMENTATION DIAGRAM
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL OBSERVATIONS SPECIAL INSPECTIONS
S-101 FLARE AND COMBUSTION BLOWER FOUNDATION
S-102
S-501 TYPICAL STRUCTURAL DETAILS
E-100 ELECTRICAL SITE PLAN
E-501 ELECTRICAL DETAILS
E-601 ELECTRICAL SINGLE LINE DIAGRAM
S-301 FENCING SECTIONS
BLOWER SKID FOUNDATION DETAILS
CIVIL DETAILSC-501
PA-001-1451
GAS HANDLING SYSTEM TOP ASSEMBLY
OS-009-0334 OVERALL SITE LAYOUT
FLARE TOP ASSEMBLY 92� OD X 420� TALL (1 OF 2)
PA-001-1451
PA-001-1454
PA-001-1452
COMBUSTION AIR BLOWER TOP ASSEMBLY
SHEET INDEX
SHEET NUMBER DESCRIPTION
ME-009-0717 FLARE P ID (1 OF 3)
ME-009-0717 FLARE P ID (2 OF 3)
ME-009-0717 FLARE P ID (3 OF 3)
PA-002-0801 CONTROL PANEL
EE-003-0697 480 V 3 PHASE ELEMENTARY (1 OF 2)
EE-003-0697 480 V 3 PHASE ELEMENTARY (2 OF 2)
EE-005-0853 120 VAC INSTRUMENTATION ELEMENTARY (1 OF 4)
EE-005-0853 120 VAC INSTRUMENTATION ELEMENTARY (2 OF 4)
EE-005-0853 120 VAC INSTRUMENTATION ELEMENTARY (3 OF 4)
EE-005-0853 120 VAC INSTRUMENTATION ELEMENTARY (4 OF 4)
FLARE TOP ASSEMBLY 92� OD X 420� TALL (2 OF 2)
21700 COPLEY DRIVE, SUITE 200
DIAMOND BAR, CA 91765
TEL 909.860.7777 FAX 909.860.8017
S-502 TYPICAL STRUCTURAL DETAILS
S-100 OVERALL FOUNDATION PLAN
G-001 CONSTRUCTION NOTES
DATE
C-101 OVERALL CONSTRUCTION SITE PLAN
C-102 GRADING PLAN
S-503 TYPICAL STRUCTURAL DETAILS
PA-001-1493 AIR COMPRESSOR TOP ASSEMBLY
JANUARY 2026
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \G
-0
C O
N
ST
R U
C
TI
O N
N O
TE
S.
dw g
L ay ou t:
G -0
U se r:
C H
EL
SE
A.
EV
AN
S
Ja n
, 2
- 6 :1
9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
G-001
NOTES:
1. CONTRACTOR TO SURVEY AND STAKE CONCRETE CORNER LOCATIONS AND OBTAIN APPROVAL FROM THE ENGINEER AND OWNER PRIOR TO
PROCEEDING.
2. THE CONTRACTOR SHALL LAY OUT THE PIPE TO CONFORM TO FIELD CONDITIONS. PROVIDE 36" MINIMUM COVER AND 5% MINIMUM SLOPE CROSSING BELOW PERIMETER AND MAIN HAUL ROADS. PROVIDE MINIMUM PIPE DRAINAGE SLOPES OF 3% WITHIN WASTE LIMIT AND 1% OUTSIDE OF WASTE LIMIT. CONTRACTOR RESPONSIBLE FOR CUT (12" MAX, UNLESS OTHERWISE NOTED PER PLAN) AND FILL BENEATH PIPE TO
ENSURE PROPER DRAINAGE, AS APPROVED BY THE ENGINEER AND OWNER.
3. FEATURES, CONTOURS, AND ELEVATIONS OF THESE BASE MAPS ARE APPROXIMATE INDICATIONS OF CURRENT AND FUTURE CONDITIONS.
CONTRACTOR IS RESPONSIBLE FOR INSPECTING WORK AREAS AT PRE-BID SITE WALK TO ASCERTAIN THE CURRENT CONDITIONS FOR BIDDING PURPOSES. CONTRACTOR SHALL VERIFY THE ACTUAL LOCATIONS OF THESE ELEMENTS PRIOR TO, AND DURING CONSTRUCTION, AND SHALL FINALIZE THE GAS SYSTEM LOCATIONS TO ACCOMMODATE FINAL FIELD CONDITIONS, AS APPROVED BY THE ENGINEER AND OWNER.
4. ALL CONNECTIONS TO EXISTING PIPING SHALL BE CONFIRMED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. SOME CONNECTIONS MAY
REQUIRE EXCAVATION.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL DISCONNECTIONS AND RECONNECTIONS FOR INSTALLATION OF ALL PROJECT
RELATED PIPING WHERE NECESSARY.
6. WORK SHALL NOT VARY FROM DESIGN WITHOUT APPROVAL OF THE ENGINEER. WORK THAT VARIES FROM DESIGN WITHOUT APPROVAL WILL BE SUBJECT TO REWORK TO MAINTAIN ADHERENCE TO THE APPROVED DESIGN. ANY REWORK WILL BE PAID FOR BY THE CONTRACTOR ENTIRELY.
7. FORCE MAIN TO BE PRESSURE TESTED IN TRENCH FOR 30 MINUTES AT 4 PSIG THEN 30 MINUTES AT 100 PSIG. GREATER THAN 10% DROP IN PRESSURE OVER 1 HOUR SHALL INDICATE A LEAK EXISTS AND SHALL BE REPAIRED. PIPE SHALL BE TESTED IN SEGMENTS NO LONGER THAN
2,000 FEET UNLESS APPROVED BY THE ENGINEER.
8. ALL PIPING GREATER THAN 6 INCHES IN DIAMETER SHALL BE PRESSURE TESTED FOR 1 HOUR AT 10 PSIG. GREATER THAN 10% DROP IN PRESSURE OVER 1 HOUR SHALL INDICATE A LEAK EXISTS AND SHALL BE REPAIRED AND RETESTED. PIPE SHALL BE TESTED IN SEGMENTS NO
LONGER THAN 2,000 FEET UNLESS APPROVED BY THE ENGINEER.
9. CONTRACTOR TO REMOVE AND REUSE EXISTING PUMPS, PIPING AND FITTINGS WHERE APPLICABLE. CAP ALL ABANDONED PIPE. IF ABANDONED PIPE IS HDPE, USE FUSED ON HDPE CAP. IF ABANDONED PIPE IS PVC, USE PVC SCH 40 CAP SECURED WITH SET SCREWS AT 90° AND CEMENT.
10. ALL EXISTING PIPING THAT IS NOT IN USE, AS DIRECTED BY THE OWNER, SHALL BE RELOCATED BY THE CONTRACTOR TO THE ON-SITE
STORAGE FACILITY AS DIRECTED BY THE OWNER.
11. CONTRACTOR TO USE FACTORY MOLDED/FABRICATED CONCENTRIC REDUCER FITTINGS AS NECESSARY.
12. CONTRACTOR TO PROTECT IN PLACE THE EXISTING ABOVE AND BELOW GRADE LATERALS DURING CONSTRUCTION. IF EXISTING PIPING NEEDS TO BE RELOCATED TEMPORARILY DURING CONSTRUCTION, THE CONTRACTOR WILL ENSURE CONSTANT SLOPE IS MAINTAINED ON THE PIPE AND THE LATERALS WILL BE RETURNED TO THEIR EXISTING CONDITION FOLLOWING CONSTRUCTION ACTIVITIES.
13. ELECTROFUSION COUPLERS SHALL NOT BE USED UNLESS APPROVED BY THE ENGINEER AND OWNER.
14. ALL EQUIPMENT, CONDUIT, PIPING AND OTHER MATERIALS, UNLESS OTHERWISE NOTED, ARE TO BE PROVIDED BY THE CONTRACTOR.
15. THE CITY SHALL FURNISH, PROVIDE AND DELIVER THE PROPOSED EQUIPMENT OF THIS PROJECT. THE CONTRACTOR SHALL OFF-LOAD AND INSTALL THE EQUIPMENT FURNISHED BY THE CITY AND CONSTRUCT THE ASSOCIATED IMPROVEMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT TO CONSTRUCT A NEW FLARE SYSTEM IN ACCORDANCE WITH THIS CONTRACT. THE WORK SHALL INCLUDE FURNISHING AND INSTALLING ALL MATERIALS NOT PROVIDED BY THE MANUFACTURER, AND COORDINATING WITH THE MANUFACTURER FOR ANY MISSING PARTS AND MATERIALS FOR THE PROPOSED SYSTEM, COMPLETE AND IN PLACE.
SEE THE CONSTRUCTION SPECIFICATIONS FOR THE MATERIALS TO BE PROVIDED BY THE MANUFACTURER.
1. 2025 AS-BUILT SURVEY INFORMATION PROVIDED BY PAUL-HANAGAN SURVEYING ON SEPTEMBER 11, 2025.
2. AERIAL SURVEY OF THE LANDFILL PROPERTY WAS PERFORMED BY ERIK OHLSON & ASSOCIATES PROFESSIONAL LAND SURVEYORS ON MARCH 7, 2025.
3. 2024 GCCS AS-BUILT INFORMATION PROVIDED BY OPAL FUELS, DATE OF RECORD DRAWINGS: MAY 29, 2024.
4. PROPERTY LINE INFORMATION PROVIDED BY PAUL-HANAGAN SURVEYING ON JULY 8, 2025.
GENERAL CONSTRUCTION NOTES:
CONSTRUCTION NOTES
S-101
M-501
S-102
M-501
S-502
CONSTRUCTION NOTES
S-102
B-B S-301
A-A S-301
M-501
M-501
M-501
M-501
S-502
M-501
C-501
C-501A-A
S-502
S-101
M-501
S-502
M-501
M-501
108108
M-501
M-501
E-501
S-502
S-502
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_G
2_
SY
M
BO
LS
A
N D
A
BB
R
EV
IA
TI
O N
S.
dw g L ay ou t:
G
-0
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 5
:5 8p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
G-002SYMBOLS AND ABBREVIATIONS
COMPRESSOR
SELECTOR
INSTRUMENT SYMBOLS
FILTER/REGULATOR/LUBRICATOR
VARIABLE SPEED DRIVE
GROUND
HIGH DENSITY POLYETHYLENE
HAND-OFF-AUTO
FLOW SWITCH OR FINISH SURFACE
FIBERGLASS REINFORCED PLASTIC
FLOW SAFETY VALVE (CHECK VALVE)
GROUND FAULT INTERRUPTER
GAS MONITOR
GROUND FAULT
FUSE HOLDER
GRADE BREAK
FLOW VALVE
FUTURE
FLOW SWITCH LOW
FLOW TRANSMITTER
FUSE
FLOW SWITCH HIGH
PRESSURE CONTROL VALVE
PRESSURE INDICATOR
POLYETHYLENE
PHONE
PILOT GAS
PRESSURE DIFFERENTIAL INDICATOR
PRESSURE ALARM LOW LOW
PRESSURE ALARM HIGH HIGH
PURGE AUTO
PRESSURE ALARM HIGH
PRESSURE ALARM LOW
PRESSURE DIFFERENTIAL INDICATOR
PRESSURE CONTROLLER
PUMP
EVENT INDICATOR CONTROLLER
POSITION SWITCH CLOSED
POSITION SWITCH OPENED
POSITION INDICATOR
POSITION SWITCH
POSITION CONTROLLER
POSITION ALARM
EVENT INDICATOR
VIBRATION SWITCH HIGH
VIBRATION TRANSMITTER
EVENT ALARM
EXPLOSION PROOF
WEATHER PROOF
TRANSFORMER
WATTS
WATER COLUMN
MOTOR OPERATED VALVE
EXISTING
TEMPERATURE
NAMEPLATE
FLOW ELEMENT (FLOW METER)
FLOW TOTALIZER INDICATOR
FLOW INDICATING RECORDER
FLOW INDICATING TRANSMITTER
FLARE
FLEXIBLE HOSE
FORWARD
FLOW RECORDER
FILTER REGULATOR
FAIL OPEN
PORT FILTER
FULL LOAD AMPS
FLOWLINE
FINISH GRADE
FLAME FAILURE ALARM
FLOW INDICATOR
OXYGEN ALARM HIGH HIGH
OXYGEN TRANSMITTER
OXYGEN INDICATING RECORDER
OXYGEN INDICATOR
OXYGEN ELEMENT
OVERLOAD
OXYGEN INDICATOR TRANSMITTER
OXYGEN SENSOR FAILURE
NOT TO SCALE
OPEN/CLOSE
OXYGEN
OXIDES OF NITROGEN
OXYGEN ANALYZER
OXYGEN ALARM HIGH
ON CENTER
FUSED DISCONNECT
FLOW CONTROL VALVE
FEEDER
FLOW ALARM LOW LOW
FAIL CLOSE
FLOW CONTROLLER
FURNISHED BY OTHERS
FILTER
FLOW ALARM HIGH HIGH
FLOW ALARM LOW
FLOW ALARM HIGH
FLAME ARRESTER
DEGREE FAHRENHEIT
EXPLOSION PROOF
NORMALLY OPEN TIMED TO CLOSE
NORMALLY CLOSED TIMED TO OPEN
NORMALLY CLOSED TIMED TO CLOSE
NORMALLY OPEN
NOT IN CONTRACT
NEGATIVE
NORMALLY OPEN TIMED TO OPEN
NEUTRAL BLOCK
NORMALLY CLOSED
NON-AUTOMATIC
MANWAY
MOUNTED
MAIN SWITCH BOARD
MOTOR STARTER
VIBRATION ALARM
VIBRATION INDICATING RECORDER
VIBRATION ALARM HIGH HIGH
VARIABLE FREQUENCY DRIVE
VIBRATION INDICATOR
VAPOR PROOF
VIBRATION SWITCH
VIBRATION ALARM HIGH
UNINTERRUPTIBLE POWER SUPPLY
TEMPERATURE TRANSMITTER
UNDERGROUND
VESSEL
ULTRAVIOLET SCANNER
TYPICAL
TEMPERATURE VALVE
TEMPERATURE SAFETY VALVE
TEMPERATURE SAFETY ELEMENT
TEMPERATURE SWITCH HIGH
TEMPERATURE SWITCH LOW
TEMPERATURE RECORDER
TIGHT SHUTOFF
TEMPERATURE SWITCH OR TOP OF SLAB
TIMER
TEMPERATURE INDICATOR RECORDER
TEMPERATURE ELEMENT WELL
TEMPERATURE ELEMENT SWITCH
TEMPERATURE INDICATOR
TEMPERATURE INDICATOR CONTROLLER
TEMPERATURE INDICATOR TRANSMITTER
THERMOSTAT
ELECTRICAL DISTRIBUTION PANEL
DIFFERENTIAL PRESSURE SWITCH
DIFFERENTIAL PRESSURE INDICATOR
ELECTRICAL METALLIC TUBING
VOLTAGE INDICATOR
EMERGENCY
EQUIPMENT
ENCLOSURE, ENCLOSED
ELAPSED TIME METER
EXHAUST
ELEVATION
DRAWING
VOLTAGE TRANSFORMER
ELECTRICAL MOTOR
DISCONNECT SWITCH
MANHOLE
METHANE INDICATOR
MODEM
METHANE INDICATING RECORDER
METHANE INDICATOR TRANSMITTER
MOTOR
MANUAL MOTOR STARTER
MINIMUM
METHANE ALARM LOW LOW
MOTOR CONTROL CENTER
MAIN CONTROL PANEL
THOUSAND CIRCULAR MILS
MAXIMUM
MANWAY
MAGNETIC
CONTROL VALVE (MODULATING)
CONTROL POWER TRANSFORMER
DISTRIBUTION
DAYLIGHT
CURRENT TRANSFORMER
DRYER
CURRENT SWITCH HIGH
METHANE ANALYZER
LUBRICATOR
METHANE ALARM LOW
MILLIAMPS
MOTOR
LIGHTING
LEVEL TRANSMITTER OR LIGHT(S)
LEVEL SWITCH LOW LOW
LEVEL SWITCH
LIGHTING PANEL
LOCK-OUT-STOP
LEVEL SWITCH LOW
LEVEL SWITCH HIGH HIGH
LEVEL SWITCH HIGH
LOCAL
TEMPERATURE ALARM LOW
TEMPERATURE ALARM LOW LOW
TEMPERATURE CONTROLLER POSITIONER
TEMPERATURE CONTROLLER
TEMPERATURE ELEMENT (THERMOCOUPLE)
TEMPERATURE CONTROL VALVE
TIME DELAY RELAY
TERMINAL BLOCK
TEMPERATURE ALARM HIGH HIGH
TEMPERATURE ALARM HIGH
TANK
TACHOMETER
STRAINER
SWITCH
SYSTEM
SURGE ARRESTOR
SHUNT TRIP
STATION
STANDARD
SOLENOID VALVE
SAMPLE PORT
STAINLESS STEEL
SPECIFICATION
SEQUENCE, SEQUENCER
SIGHT GLASS
SPEED INDICATOR
SHEET
SHIELD, SHIELDED
SUPPLEMENTAL FUEL
SENSOR FAILURE
MISCELLANEOUS SYMBOLS
RELAY FUNCTION DESIGNATIONS TYPES
CURRENT TRANSFORMER
ALUMINUM
KILOWATTS
COMBUSTIBLE GAS HIGH HIGH
COMBUSTIBLE GAS INDICATOR
CIRCUIT
CONDUIT ONLY
CHANNEL
LOWER EXPLOSIVE LIMIT
LEVEL GAGE
LANDFILL GAS
LUBE OIL
LEVEL ELEMENT
LATCHING CONTROL RELAY
LOCAL CONTROL PANEL
LAMP
LEVEL CONTROLLER HIGH
LEVEL CONTROLLER LOW
LEVEL CONTROLLER
LEVEL ALARM LOW LOW
LEVEL ALARM LOW
LEVEL ALARM HIGH HIGH
LEVEL ALARM HIGH
BARE COPPER
AUTOMATIC
BURNER ALARM LOW LOW
BLOWER
AMPERE TRIP
AMPERES, AMPERAGE
INSTRUMENT
KILOVOLTS
KILOVOLT AMPERES
TIME INDICATOR
CURRENT TRANSMITTER
SHORT CIRCUIT CURRENT
INVERT
CURRENT INDICATING RECORDER
IGNITOR
INSTRUMENT AIR SUPPLY
CURRENT ALARM LOW
CURRENT ALARM HIGH HIGH
CURRENT ALARM HIGH
INSTANTANEOUS
CURRENT ALARM LOW LOW
STANDARD CUBIC FEET PER MINUTE
SHUTDOWN OR ON
SECTION
SECONDARY, SECONDS
SHUTDOWN VALVE
SHUTDOWN
SCHEDULE
RETENTION TIME CALCULATOR
REVOLUTIONS PER MINUTE
RIGID GALVANIZED STEEL
AIR STRIPPER
RETENTION TIME
SPECTACLE BLIND
RELAY MODULE
RESISTOR
POLYVINYL CHLORIDE
RUPTURE DISK ALARM HIGH
RUPTURE DISK
RUPTURE DISK SWITCH
RECEPTACLE
TOTALIZER
POWER
REQUIRED
PRESSURE SAFETY ELEMENT
PRESSURE TRANSMITTER
POUNDS PER SQUARE INCH
PRESSURE RELIEF VALVE
PRESSURE SWITCH LOW
PRESSURE SWITCH HIGH
PRESSURE SWITCH
MISCELLANEOUS ABBREVIATIONS
ACTUAL CUBIC FEET PER MINUTE
ANALOG OUTPUT
ANALOG INPUT OUTPUT
ANALOG INPUT
AIR CONDITIONER
CURRENT INDICATOR
CURRENT
HAND VALVE PORT
HEAT TRACE
HAND VALVE
HEATER
HERTZ
HORSEPOWER OR HIGH POINT
HAND SWITCH
PROGRAMMABLE LOGIC CONTROLLER
POWER PANEL or POWER POLE
PRESSURE INDICATING RECORDER
POSITION, POSITIVE
POSITIONER
POTENTIOMETER
PANEL
PILOT
PIPING AND INSTRUMENTATION DIAGRAM
PRESSURE INDICATING CONTROLLER
INDUSTRIAL TECHNICAL CORPORATION
LEVEL INDICATOR
PUSH BUTTON
BUILDING PROTECTION SYSTEM
ACTUATOR
AUTO DIALER SYSTEM
AMPERE FRAME SIZE (CIRCUIT BREAKER)
ABOVE FINISH FLOOR
AMERICAN WIRE GAUGE
BATTERY
BURNER GLASS
BURNER ELEMENT (UV SCANNER)
BREAKER
BILL OF MATERIAL
BURNER SWITCH (FLAME SAFEGUARD)
BRITISH THERMAL UNIT
CONDUIT
CURRENT ALARM HIGH
CURRENT ALARM LOW
CABLE
CENTER TO CENTER
COMBUSTIBLE GAS HIGH
COMBUSTIBLE GAS TRANSMITTER
CHART RECORDER
CURRENT INDICATOR
COUNTER
COMMUNICATION
CONTROL PANEL
CHLORINATED POLYVINYL CHLORIDE
CONTROL RELAY
CARBON STEEL
CURRENT SWITCH LOW
COPPER
DIGITAL INPUT
DELTA OR DIFFERENTIAL PRESSURE
PLC CONTROLLED DEVICE
LOCALLY PANEL MOUNTED UNIT
INSTRUMENT MOUNTED BEHIND BOARD
CONTROL PANEL MOUNTED INSTRUMENT
LOCALLY MOUNTED INSTRUMENT
REMOTE CONTROL
REMOTE MONITORING
PILOT LIGHT (R=RED; G=GREEN; A=AMBER; B=BLUE;
INSTRUMENT MOUNTED BEHIND LOCAL BOARD
LOCAL BOARD MOUNTED INSTRUMENT
W=WHITE; C=CLEAR; N=NEON)
CONTROL PANEL MOUNTED INSTRUMENT
AUTO/MANUAL
LOCAL/REMOTE
HAND/OFF/AUTO
ANALOG/DIGITAL
CURRENT TO PNEUMATIC
DETAIL NUMBER
INTERLOCK IF ANY ONE OR MORE INPUTS EXIST
RESET FOR LATCH TYPE ACTUATOR
INTERLOCK
SOLENOID VALVE
INTERLOCK IF ALL INPUTS EXIST
SHEET NUMBER DETAIL IS DRAWN ON
I/P
A/M
A/D
L/R
HOA
S
I
R
AND
OR
PILOT TUBE OR PILOT VENTURI TUBE
PISTON OPERATED VALVE WITH HANDWHEEL,
SELF-CONTAINED PRESSURE CONTROL VALVE
HYDRAULIC OR PNEUMATIC (SPRING RETURN)
SOLENOID-OPERATED 2-WAY VALVE
INSTRUMENTATION DEVICES & ACCESSORIES
LINE & SIGNAL SYMBOLS
SIDE-MOUNTED
PISTON-OPERATED VALVE
SOLENOID-OPERATED 3-WAY VALVE
PRESSURE RELIEF VALVE
PISTON-OPERATED VALVE WITH OPEN AND
CLOSED POSITION SWITCHES AND WITH
HANDWHEEL, SIDE MOUNTED
CONTROL VALVE WITH I/P TRANSDUCER
BUTTERFLY VALVE, HAND OPERATED
BALL VALVE, HAND OPERATED
NEEDLE VALVE, HAND OPERATED
HAND VALVE, HAND OPERATED
3-WAY HAND VALVE, HAND OPERATED
PRESSURE REGULATOR W/PRESSURE GAUGE
BUTTERFLY VALVE, AUTOMATED
GEAR OPERATOR
Y-STRAINER
PNEUMATIC POSITIONER
FLEX CONNECTOR
FLEX CONNECTOR WITH FLANGE CONNECTION
FLANGE CONNECTION
BLIND FLANGE
UNION
CAP OR PLUG
CONCENTRIC REDUCER
ECCENTRIC REDUCER
SAMPLE PORT
MANUAL ACTUATOR/OVERRIDEMA
G
S
S
PRV
G
ZSO ZSC
P
G
A
PI
CMP or COMP
CV
CPT
DISTR
DL
CT
D
CSH
AL
CGHH
CGI
CIR
CO
CH
BC
AUTO
BALL
B
AT
AMP
ACFM
AOUT
AIO
AI
AC or A/C
BPS
A
ADS
AF
AFF
AWG
BATT
BG
BE
BKR
BOM
BS
BTU
C
CAH
CAL
CBL
CC
CGH
CGT
CHR
CI
CNT
COMM
CP
CPVC
CR
CS
CSL
CU
DI
DP
ETM
FALL
EXIST
F.C.
FCV
FAHH
FBO
FA
DWG
E
EMER
ENCL
EDP
DPI
DPS
E/E
EI
EL OR ELEV
EMT
EQPT
EXH
EXP
°F
FLT or F
FAH
FAL
FC
FD
DS
FDR
FE
FFA
FG
FI
FIR
FIT
FL
FLA
FLR
FX or FLEX
FLTP
F.O.
FOR
FQI
FR
FRG
FRL
FRP
FS
FSH
FSL
FSV
FT
FU
FUH
FUT
FV
GB
GF
GFI
GM
GND or GRND
HDPE
HOA
HP
HS
HT
HTR
HV
HVP
HZ
I
II
I/I
IAH
IAHH
IAL
IALL
IAS
IG or IGN
IIR
INST
INSTR
INV
ISC
IT
ITC
KI
KV
KVA
KW
LAH
LAHH
LAL
LALL
LC
LCH
LCL
LCP
LCR
LE
LEL
LFG
LG
LI
LMP
LO
LOC
LOS
LP
LS
LSH
LSHH
LSL
LSLL
LT
LTG
LUB
M
MA
M.A.
MAL
MALL
MAG
MAN
MAX
MCC
MCM
MCP
MH
MI
MIR
MIN
MIT
MMS
MOV
MS
MSB
MTD
M.W.
NA
NBK
N.C.
N.C.T.C.
N.C.T.O.
NEG
NIC
N.O.
N.O.T.C.
N.O.T.O.
NP
NTS
NOX
O O/C
O.C.
OA
OAH
OAHH
OE
OI
OIR
OT
OIT
OSF
OL
PDI
PMP or P
PB
PA
PAH
PAHH
PAL
PALL
PC
PCV
PDI
PE
PG
PH
PI
P&ID
PIC
PIR
PLC
PLT
PNL
POS
POT
POZ
PP
PS
PSE
PSH
PSI
PSL
PT
PRV
PVC
PWR
QL
REQD
RD
RDAH
RDS
RECEPT
RES
RGS
RM
RPM
RT
RTC
S
SB
SCFM
SCH
SD
SD/O
SDV
SEC
SECT
SEL
SEQ
SF
SFR
SG
SHLD
SHT
SI
SPECS
SS
SSR
ST
STA
STD
STR
SW
SYS
T or TK
TACH
TAH
TAHH
TAL
TALL
TB
TC
TCV
TCZ
TD or TDR
TE
TEMP
TES
TEW
THERM
TI
TIC
TIR
TIT
TMR
TR
TS
TSE
TSH
TSL
TSO
TSV
TT
TV
TYP
UG
UPS
UV
V
VA
VAH
VAHH
VFD
VI
VIR
VP
VS
VSD
VSH
VT
W
W.C.
WP
XFMR
XP
YA
YI
YIC
ZA
ZC
ZI
ZS
ZSC
ZSO
MOT
SP
MOD
SOV
GRANULAR ACTIVATED CARBONGAC
PRESSURE INDICATING TRANSMITTERPIT
GAS COLLECTION AND CONTROL SYSTEMGCCS
BOTTOMBTM
EXPANSION JOINT
VACUUM BREAKVB
STANDARD DIMENSION RATIOSDR
ANGLE VALVE
AUXILIARY PORTAP
BURNERBNR
BLACK IRONBI
CHECK VALVE
ELECTRIC MOTOR WITH FAN
BUTTERFLY VALVE, GEAR OPERATEDG
MAN WELL
BLOWER
EXISTING LFG HEADER OR LATERAL
PROPOSED PROPANE GAS PIPING
PROPOSED ABOVE GRADE AIR PIPING
PROPOSED 4-INCH X 2-INCH BELOW GRADE DUAL
CONTAINED CONDENSATE PIPING
PROPOSED LFG PIPING AND EQUIPMENT
PROPOSED 4-INCH X 2-INCH ABOVE GRADE DUAL
CONTAINED CONDENSATE PIPING
PROPOSED ABOVE GRADE CONDENSATE PIPING
PROPOSED BELOW GRADE AIR PIPING
246 244
W-3G
W-11G
W-2G
W-8G
W-19G-SR2,MR2
W-20G
W-7G
W-19G-DR2
W-11GR
W-21G W-4GR
CELL 2
CELL 3A
CELL 1
CELL 3B
LEGEND
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING POWER POLE
EXISTING OVERHEAD ELECTRIC
PROPERTY LINE
EXISTING 1-INCH AIR PIPING
EXISTING 2-INCH CONDENSATE PIPING
EXISTING 4-INCH LFG (BELOW GRADE)
EXISTING 4-INCH LFG
EXISTING 6-INCH LFG (BELOW GRADE)
EXISTING
EXISTING 6-INCH LFG
EXISTING 8-INCH LFG (BELOW GRADE)
EXISTING 8-INCH LFG
EXISTING 10-INCH LFG (BELOW GRADE)
EXISTING
EXISTING 10-INCH LFG
EXISTING 12-INCH LFG (BELOW GRADE)
EXISTING 12-INCH LFG
EXISTING LFG PIPING
EXISTING SUMP
EXISTING GAS WELL
EXISTING GAS PROBE
CELL LIMIT
EXISTING SHRUBBERY
EXISTING UNPAVED ROAD
EXISTING BUILDINGS
C-100EXISTING SITE PLAN
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \C
-1
E
XI
ST
IN
G S
IT
E
PL
AN
.d w g L ay ou t:
C
-1
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 5
:5 8p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
246 244
C P-
X
X
14% SLOPE
4% SLOPE
X X
X
XXXXXX
X
X X
X X
X X X X X X X X X
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_C
1_ C
O N
ST
R
U C
TI
O
N P
LA
N
.D W
G L ay ou t:
C
-1
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 5
:5 9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
C-101OVERALL CONSTRUCTION SITE PLAN
LEGEND
NOTES:
1. ENDANGERED SPECIES AREA. CONTRACTOR TO AVOID ANY AND ALL CONSTRUCTION ACTIVITIES
IN THIS AREA TO MINIMIZE ANY DISTURBANCES.
EXISTING LFG HEADER OR LATERAL (4-INCH , 6-INCH , OR 8-INCH )
EXISTING MAJOR CONTOUR
PROPOSED FENCE
EXISTING STORM DRAIN
EXISTING MINOR CONTOUR
TREE LINE/SHRUBBERY
PROPOSED WALL
PROPOSED CONCRETE FOUNDATION
EXISTING CONDENSATE PIPING
EXISTING AIR PIPING
WOODRAT MIDDEN ENDANGERED SPECIES AREA (SEE NOTE 1)
PROPOSED LFG PIPING AND EQUIPMENT
92 13
95 96 97
CONSTRUCTION NOTES
PROPOSED 4-INCH X 2-INCH BELOW GRADE DUAL CONTAINED CONDENSATE PIPING
PROPOSED PROPANE GAS PIPING
PROPOSED 1-INCH ABOVE GRADE HDPE SDR-9 AIR PIPING
PROPOSED 4-INCH X 2-INCH ABOVE GRADE DUAL CONTAINED CONDENSATE PIPING
M-501
M-501 1
M-501
M-501
M-501
M-501
108108
M-501
M-501
X X
PROPOSED 1-INCH BELOW GRADE HDPE SDR-9 AIR PIPING
246 244
14 1
LIMITS OF
GRADING
T/CONC EL:240.60
T/CONC EL:240.60
X X
XX
X
X X
X X
X X
X
XXXXXXXXXXXX
X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X
243.00
T/WALL-3
239.70
FLR-1
239.84
FLR-3
239.96
BLR-1
242.11
T/WALL-2
239.44
B/WALL-2
239.68
RD-1
239.80
BLR-2
239.44
FLR-2
242.37
T/WALL-1
239.26
B/FNC-1
239.55
RD-2
239.95
RD-4
239.95
RD-3
240.02
BLR-4
242.73
T/WALL-4
240.06
B/WALL-4
240.30
BLR-3
240.33
B/WALL-3
239.62
FLR-4
239.70
B/WALL-1
2:
(M
AX
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \C
-1
G R
AD
IN
G P
LA
N
.d w g L ay ou t:
C
-1
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 5
:5 9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
GRADING PLAN
EXISTING LFG HEADER OR LATERAL (4-INCH , 6-INCH , OR 8-INCH )
EXISTING MAJOR CONTOUR
PROPOSED FENCE
C-102
PROPOSED GRAVEL
ADL
ADL
MAS
GRB
EXISTING STORM DRAIN
EXISTING MINOR CONTOUR238
TREE LINE/SHRUBBERY
CONSTRUCTION NOTES
EXISTING STORM DRAIN TO BE REMOVED AND RELOCATED
RELOCATED STORM DRAIN
PROPOSED WALL
PROPOSED ASPHALT DRIVEWAY
PROPOSED CONCRETE FOUNDATION
PROPOSED CONTOUR
EXISTING LEACHATE PIPING
CONSTRUCTION NOTES
LEGEND
PROPOSED LIMIT OF GRADING
EXISTING LFG HEADER OR LATERAL (4-INCH , 6-INCH , OR 8-INCH )
C-501 A-A
S-502
PROPOSED GRATED LINE DRAIN
* NOTE:
ELEVATIONS SHOWN ARE ON GROUND
SURFACE ADJACENT TO CONCRETE
PAD. TOP OF CONCRETE PAD
ELEVATIONS ARE 240.60 AS NOTED ON
EACH PAD.
B-B S-301 A-A
S-301
C-501
C-501
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_C
1_ C
IV
IL
D
ET
AI
LS
.d w g L ay ou t:
C
-5
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 5
:5 9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
C-501
ADL
ADL
MAS
GRB
DETAIL - PAVEMENT STRUCTURAL SECTION
REFERENCE SHEET: C-101 NTS
DETAIL - PAVEMENT THICKENED EDGE2
REFERENCE SHEET: C-101 NTS
DETAIL3
REFERENCE SHEET: C-101NTS
8" 8"
4" ASPHALTIC CONCRETE PAVING
8" AGGREGATE BASE COURSE
(COMPACTED TO 95% ASTM D-1557)
SUBGRADE (COMPACTED EARTH FILL OR
UPPER 12" OF EXISTING SCARIFIED AND
RECOMPACTED TO 95% ASTM D-1557)
ASPHALTIC CONCRETE PAVING
8" AGGREGATE BASE COURSE
(COMPACTED TO 95% ASTM D-1557)
SUBGRADE
(95% COMPACTION)
CIVIL DETAILS
DESIGN GRADE
(SEE C-101)
__" GRAVEL COVER
(D50 =__")
GEOTEXTILE
WEED MAT
SUBGRADE (COMPACTED
EARTH FILL OR UPPER 12"
OF EXISTING SCARIFIED
AND RECOMPACTED TO
95% ASTM D-1557)
X
X
X X
XX
X
X
4% SLOPE
X X
X X
X X
X X
X
XX
XXXXXXXXXXXXXXXXXX
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_M
0- M
2_
C O
N
ST
R U
C
TI
O N
P
LA
N S.
D W
G L ay ou t:
M
-1
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 6
:0 0p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
M-101CONSTRUCTION SITE PLAN
CONSTRUCTION NOTES
A-A' M-301
B-B' M-301
30 35
LEGEND
PROPOSED LFG PIPING AND EQUIPMENT
EXISTING MAJOR CONTOUR
PROPOSED FENCE
EXISTING STORM DRAIN
EXISTING MINOR CONTOUR
TREE LINE/SHRUBBERY
PROPOSED CONCRETE FOUNDATION
EXISTING LEACHATE PIPING
PROPOSED WALL
S-101
S-502
S-502
M-501
M-501
S-102
S-102
S-101
S-502
SITE ACCESS ROADS
X
X X
XX
X
X
4% SLOPE
X X
X X
X X
X X
X
XX
XXXXXXXXXXXXXXXXXX
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_M
0- M
2_
C O
N
ST
R U
C
TI
O N
P
LA
N S.
D W
G L ay ou t:
M
-1
U se r:
C
H
EL
SE
A.
EV
AN
S Ja n
, 2
- 6
:0 0p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
M-102UTILITY SITE PLAN
M-501
LEGEND
CONSTRUCTION NOTES
PROPOSED PROPANE GAS PIPING
PROPOSED PRESSURE REGULATOR WITH PRESSURE GAUGE
PROPOSED HOSE WITH ADAPTER
PROPOSED SOLENOID VALVE
PROPOSED BALL VALVE
PROPOSED PIPING AND EQUIPMENT
EXISTING MAJOR CONTOUR
PROPOSED FENCE
PROPOSED EQUIPMENT FOUNDATIONEXISTING MINOR CONTOURS
TREE LINE/SHRUBBERY
EXISTING LEACHATE PIPE
SITE ACCESS ROADS
EXISTING STORM DRAIN
90 90
102103101
PROPOSED WALL
M-501
M-501
PROPOSED 4-INCH X 2-INCH BELOW GRADE DUAL CONTAINED CONDENSATE PIPING
PROPOSED 1-INCH ABOVE GRADE HDPE SDR-9 AIR PIPING
PROPOSED 4-INCH X 2-INCH ABOVE GRADE DUAL CONTAINED CONDENSATE PIPING
X X
PROPOSED 1-INCH BELOW GRADE HDPE SDR-9 AIR PIPING
S-501
S-50198
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_M
1_
FL
AR
E
ST
AT
IO
N
S
EC
TI
O
N S.
dw g
L ay ou t:
M -3
U se r:
C H
EL
SE
A.
EV
AN
S
Ja n
, 2
- 5 :5
9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
M-301FLARE STATION SECTIONS
CONSTRUCTION NOTES
M-105
S-1013
M-501
S-502
M-501
S-502
2 A-A S-502
NTS
SECTION A-A'
NTS
SECTION B-B'
27 2337
S-102
S-502
S-102
M-501
S-502
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_M
1_
TY
PI
C
AL
D
ET
AI
LS
.d w g
L ay ou t:
M -5
U se r:
C H
EL
SE
A.
EV
AN
S
Ja n
, 2
- 6 :0
0p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
M-501TYPICAL DETAILS
NTS REFERENCE SHEET: M-102
1 ABOVE GRADE VALVE DETAIL
EXISTING GRADE
GEAR OPERATOR WITH REMOVABLE VALVE WHEEL
FOR VALVE AND LEVER OPERATOR
BUTTERFLY VALVE, SIZE PER PLAN
TAP AND THREAD 1/4" LABCOCK VALVE INTO PIPE.
WRAP THREADS WITH TEFLON TAPE. (TYP)
HDPE HEADER OR LATERAL
ON GRADE OR PIPE SUPPORTS
(SIZE PER PLAN)
HDPE FLANGE ADAPTER WITH DUCTILE IRON
BACK-UP RING AND RUBBER GASKETS (TYP
OF 2, SIZE PER PLAN)
VALVE SPACERS TO BE INSTALLED FOR
PIPES LARGER THAN 6" (SIZE PER PLAN)
NTS REFERENCE SHEET: M-101
HDPE OR SS FLANGE ADAPTER
ZINC PLATED NUTS, BOLTS,
AND WASHERS
CARBON STEEL OR DUCTILE IRON
BACK-UP RING (TYP)
NEOPRENE FULL FACE
FLANGE GASKET
HDPE OR SS PIPE
FLANGE CONNECTION2
REFERENCE SHEET: M-102NTS
LFG TIE-IN WITH TEE
HDPE LFG HEADER
HDPE MOLDED TEE
HDPE LFG PIPE
NOTES:
1. ELECTROFUSION COUPLERS SHALL NOT
BE USED UNLESS PRE-APPROVED BY
OWNER AND ENGINEER.
PIPE
GROUND
SURFACE
SOIL MOUND
NOTES:
1. SOIL MOUNDING TO BE PLACED EVERY 25 FEET AT MINIMUM.
2. MOUND SHALL EXTEND A MINIMUM OF ONE FOOT ABOVE TOP OF
PIPE AND THREE FEET WIDTH AND COMPLETED USING CLEAN
SOIL.
NTS REFERENCE SHEET: M-101, M-102
4 SOIL MOUNDING FOR ABOVE GRADE PIPE STABILIZATION
PROVIDE A MINIMUM OF 1' OF COVER
OVER THE PIPE, WITH A MINIMUM
COVERAGE LENGTH OF 3' ALONG THE
PIPE
HDPE OR SS PIPE
NTS REFERENCE SHEET: C-101, M-102
5 BURIED PIPE TRENCH
OPAL LFGTE
FACILITY
"Ø
H D
PE
S
D R
-1
FLR-1
EXISTING
TEMPORARY FLARE
" S
D R
-1
H D
PE
AIR
EXHAUST & AIR
3/4" DRAIN HOLES
NC
TYP
1/4"
8"SS101/2"SS
3/ 8"
SS
T
P
S
FLR-2
1/4"SSTSE-301
3/4"SS
1/4"SS
H
0-100" WC
1/2"SS
8"SS10
0-250°F
1/2"SS
3/ 8"
SS
T
0-60"
WC
NC
1/4"SS
K TYPEFT-301
8"SS108"SS10
7,200
SCFM MAX
50 HP
SCFM AIR
1/4"SS3/4"SS
1/4"
BLR-401
FT-401
0-8,000
SP:
0.50" WC
~24"x34"
0-5" WC
4"SS
FLT-301
BLR-301
M M
12" CLEAN-OUT
PDI
LS
M
HV-301
FCV-301 FCV-302 FCV-303
HV-213 HV-214 HV-215
HV-302 HV-303 HV-304
HVP-304HVP-305
HVP-307
HVP-306
6" S
S1
0 8" SS10
1/2" SST
TK-101/
TK-101TK-102
FCV-704
FCV-705
FCV-706
CMP-2
1/ 2"
S C
H
BI
BLR-302 BLR-303
FX-301 FX-304 FX-302 FX-305 FX-303 FX-306
6" S
S1
6" S
S1
2" S
S1
1/ 2"
S S
1/ 2"
S S
1/ 2"
S S
1/ 2"
S S
2"x1/2" 2"x1/2" 2"x1/2" 2"x1/2" 2"x1/2" 2"x1/2"
G/H
TI
TE
PT
HVP
FLTP
HVP
PT
FT
TE
HVP
FCV
FLTP
HVP
PI
HVP
FLTP
ZS
FV
FLTP
HV
BE
BG
BG
FT
M1
PS
PI
BLR
TE
TE
TE
BE
BG
FCV
BG
BG
BG
BG
AP
FCV
AP
AP
AP
TE
BG
BNR-2
IGN
PS
FX
FV
FLT-301 BLR-401
PROPOSED COMBUSTION
AIR BLOWER
MFR: INDUSTRIAL AIR TECH.
MODEL: BCHS, 227
FLOW RATE: 7,200 SCFM
SHAFT: 1045 (STANDARD)
STAINLESS STEEL DRAIN
50 HP 3550 RPM 460 V 3 PH
PROPOSED FUEL FILTER/MOISTURE SEPARATOR
MFR: PEI
MATERIAL: SS
NOZZLE SIZE: 10" INLET, 8" OUTLET
99% REMOVAL OF 6 MICRON OR LARGER
PROPOSED FLAME
ARRESTER
MFR: ENARDO
TYPE: ECCENTRIC
CONNECTION: 8" FLANGE
MATERIAL: ALUMINUM
HOUSING AND SS ELEMENT
DRAIN/PRESSURE PORTS
FLR-2
PROPOSED FLARE
MFR: PEI
SIZE: 33 MMBTU/h
FLOW: 1,000 SCFM MAX.
(30% TO 55% CH4)
FT-401
PROPOSED THERMAL MASS FLOW
METER/TRANSMITTERS
MFR: KURZ
MODEL: 756053
TYPE: INTEGRAL
POWER: 24VDC
OUTPUT: 4-20mA
FLOW: 0-8000 SCFM
BLR-301/302/303
PROPOSED CENTRIFUGAL BLOWER
MFR: CONTINENTAL
MODEL:031A-06
MOTOR: 40 HP TEFC, 3600 RPM PER
BLOWER (3 TOTAL)
TK-101/102
PROPANE BOTTLES
2 PROPOSED
SIZE: 40 LB (10 GALLON)
CMP-801
PROPOSED AIR COMPRESSOR
MFR: ATLAS COPCO
MODEL: GA 22
SIZE: 30 HP
134 CFM @125 PSIG
TSE-301
G
FT-301
PROPOSED THERMAL MASS FLOW
METER/TRANSMITTERS
MFR: KURZ
MODEL: 756410
TYPE: INTEGRAL
POWER: 24VDC
OUTPUT: 4-20mA
FLOW: 0-1500 SCFM
TO EXISTING PIPE
TO EXISTING SUMP
INCOMING LFG
FROM WELLFIELD
1/4" SS
1/4" SS
0-10" WC
G
1/4" SS 2"x1/4"
6" S
S1
8"x6" 8"x6" 8"x6"
TO EXISTING AIRLINE
AND WELLFIELD
HV-701
50/ 50
CH4/CO2
0-1500 SCFM
DRY-801
DRY-801/FLT-801
MANUFACTURER: ATLAS COPCO
DRYER: FX-61N
FILTER: UD-110+
SIZE: 400 GAL
8"x6"8"x6"8"x6"
HV-702
FCV-304
Fi le
: X :\P
R O
JE
C
TS
\S
AN
TA
C R
U Z\
7-
-4
- S an ta
C ru z Lo w -N
O x
Fl ar e\ Pr oj ec t D ra w in gs \1
-2
4-
_M
1_
PR
O C
ES
S
FL
O
W .d w g
L ay ou t:
M -6
U se r:
C H
EL
SE
A.
EV
AN
S
Ja n
, 2
- 5 :5
9p m
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
D-601PIPING AND INSTRUMENTATION DIAGRAM
FCV-701 FCV-702 FCV-703
1/ 2"
S S
1/ 2"
S S
L
H
LI-701
8" SS10
8" SS10
HVP-301
HVP-302
HVP-303
PT
1/ 4"
S S
3/4" SS
3/8" SST
3/8" SST
PDI
0-100" WC
L
LFLTP
FLTP
BG
BG
BG
BG
STP: 14.7 PSIA,
60 °F
S
C
FH
P R
O
PA
N E
,0
B
TU
/H
R
PS
FX
HVP
HVP
HVP
PT
HVP
1/4"SS
FLTP
NOx 0.025 LB/MMBTU
CO 0.06 LB/MMBTU
≥ 98% DRE NMOC'S
≥ 98% DRE NMOC'S
2"-4# INSULATION
2"-8#
HVP
HNC
0-80" WC
HVP
HVP
PS
1/4"SS
FX
FX
FX
FX
HVP
HVP
PCV
PI
1/4"SS
0-30 PSI
SP:15 PSI
HV
PCV
102PI
FV
FV
102S
S
0-6 PSI 1/2"SS
4" X2
" H D
PE
S
D R
-1
2" SS10
1" H
D
PE
S D
R -9
FLR-1
TEMPORARY FLARE
FLOW: 2,100 SCFM AT 50% CH4 MAX.
BLOWER (1 TOTAL)
BLOWER FLOW: 1,350 SCFM
10" SS10
" S
D R
-1
H D
PE
STRUCTURAL NOTES
THESE NOTES SHALL APPLY UNLESS SHOWN/INDICATED OTHERWISE ELSEWHERE IN THE STRUCTURAL DRAWINGS.
GENERAL
1. ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE 2022 EDITION OF THE CALIFORNIA BUILDING CODE (C.B.C.).
2. THE CONTRACTOR ACKNOWLEDGES RESPONSIBILITY FOR JOBSITE SAFETY AND ACKNOWLEDGES THAT THE ENGINEER WILL NOT HAVE SUCH RESPONSIBILITY. IF A LAWSUIT IS FILED BY ONE OF THE CONTRACTOR'S OR SUBCONTRACTOR'S EMPLOYEES, OR ANY ONE ELSE, THE CONTRACTOR WILL INDEMNIFY, DEFEND AND HOLD THE OWNER AND TETRA TECH, INC., THEIR PARENT AND SUBSIDIARY COMPANIES HARMLESS OF ANY AND ALL SUCH CLAIMS.
3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING WORK. SHOULD CONDITIONS EXIST WHICH ARE CONTRARY TO THOSE SHOWN ON PLANS, THE ENGINEER SHALL BE NOTIFIED IN WRITING BEFORE
PROCEEDING WITH WORK.
4. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL WORK IS ADEQUATELY BRACED AND SHORED DURING CONSTRUCTION. ALL BRACING/SHORING SHALL BE DESIGNED BY A REGISTERED ENGINEER HIRED BY THE
CONTRACTOR.
5. UNLESS DETAILED, SPECIFIED, OR INDICATED OTHERWISE, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND THESE GENERAL NOTES. TYPICAL DETAILS ARE MEANT TO APPLY EVEN THOUGH NOT REFERENCED AT
SPECIFIC LOCATIONS ON DRAWINGS WHERE THEY OCCUR.
6. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS AND PEDESTRIANS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT BE CONSIDERED AS INSPECTION OF SUCH ITEMS.
7. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS.
8. ALL WORK SHALL CONFORM TO THE PLANS AND SPECIFICATIONS IN ALL RESPECTS AND SHALL BE SUBJECT TO APPROVAL BY
THE ENGINEER.
9. BY ACCEPTING THIS CONTRACT, CONTRACTOR HEREBY RELEASES AND AGREES TO INDEMNIFY, DEFEND, HOLD HARMLESS THE OWNER, ENGINEER, (HEREINAFTER TETRA TECH, INC.), THEIR PARENT AND SUBSIDIARY COMPANIES, AGENTS, EMPLOYEES, CONSULTANTS AND REPRESENTATIVES FOR ANY AND ALL DAMAGE TO PERSONS OR PROPERTY OR WRONGFUL DEATH REGARDLESS OF WHETHER OR NOT SUCH CLAIM, DAMAGE, LOSS OR EXPENSE IS CAUSED IN WHOLE OR IN PART BY THE NEGLIGENCE, ACTIVE OR PASSIVE, OF OWNER, ENGINEER, THEIR PARENT AND SUBSIDIARY COMPANIES AS WELL AS THEIR AGENTS AND EMPLOYEES, TO THE FULLEST EXTENT PERMITTED BY LAW. SUCH INDEMNIFICATION SHALL EXTEND TO ALL CLAIMS, DEMANDS, ACTIONS, OR LIABILITY FOR INJURIES, DEATH OR DAMAGES OCCURRING AFTER COMPLETION OF THE PROJECT, AS WELL AS DURING THE WORK'S PROGRESS. CONTRACTOR FURTHER AGREES THAT IT SHALL ACCOMPLISH THE ABOVE AT ITS OWN COST, EXPENSE AND RISK EXCLUSIVE OF AND REGARDLESS OF ANY APPLICABLE INSURANCE POLICY OR
POSITION TAKEN BY ANY INSURANCE COMPANY REGARDING COVERAGE.
10.CONTRACTOR SHALL VERIFY LOCATION OF ALL SITE UTILITIES PRIOR TO STARTING WORK, BOTH ABOVE GROUND AND BELOW GROUND, WHICH MAY BE IMPACTED BY THE WORK SHOWN ON THESE DRAWINGS. ANY CONFLICTS SHALL BE BROUGHT TO
THE ATTENTION OF THE ENGINEER.
11.CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CLIENT AND TETRA TECH, INC. THEIR PARENT AND SUBSIDIARY COMPANIES, ITS EMPLOYEES, OFFICERS, OR AGENTS, HARMLESS AGAINST ANY AND ALL CLAIMS BY ANY PARTIES ARISING FROM, OR RELATED TO, ANY AND ALL DAMAGES, INCLUDING LEGAL COSTS AND ATTORNEY'S FEES, RESULTING FROM INTERFERENCE WITH, INTERRUPTION OF, DAMAGE TO, OR ANY AND ALL INJURIES WHICH RESULT FROM DAMAGE CAUSED TO SUBSURFACE INSTALLATION, WHICH IS UNFORESEEN AND DESPITE ENGINEER'S EFFORT DURING THE DESIGN PROCESS WAS NOT LOCATED, EXCEPTING ONLY THE GROSS NEGLIGENCE OR WILLFUL MISCONDUCT OF ENGINEER IN PROVIDING ITS
SERVICES.
12. ALL ITEMS SHOWN ON THESE PLANS ARE NEW UNLESS NOTED (E), EXIST. OR EXISTING.
REINFORCING NOTES
1. REINFORCEMENT FOR CONCRETE SHALL BE DEFORMED BARS CONFORMING TO A.S.T.M. SPECIFICATION A615. GRADE 60 .
WELDED REINFORCEMENT SHALL CONFORM TO ASTM A706 OR EQUAL.
2. ALL REINFORCEMENT, ANCHOR BOLTS, AND OTHER ANCHORAGES PLACED IN CONCRETE SHALL BE ACCURATELY PLACED AND POSITIVELY SECURED AND SUPPORTED BY CONCRETE BLOCKS, METAL CHAIRS, SPACERS, OR METAL HANGERS, AND SHALL BE IN POSITION BEFORE CONCRETE PLACING OR GROUTING IS BEGUN. DETAILING AND PLACING OF BARS SHALL
CONFORM TO THE A.C.I. MANUAL OF STANDARD PRACTICES.
3. BARS SPECIFIED AS "CONTINUOUS" SHALL EXTEND THE FULL LENGTH OF THE MEMBER CONTAINING THEM AND MAY BE SPLICED (UNLESS NOTED OR SHOWN WITHOUT SPLICES ON THE PLANS). IN CONCRETE, PROVIDE LAPS PER TYPICAL DETAILS.
STAGGER ALL SPLICES.
4. DOWELS SHALL BE PROVIDED AT ALL POUR JOINTS AND SHALL BE THE SAME SIZE AND SPACING AS REINFORCING DIRECTLY
BEYOND POUR JOINTS.
5. WELDING OF REINFORCING STEEL, METAL INSERTS AND CONNECTIONS IN REINFORCED CONCRETE OR MASONRY CONSTRUCTION SHALL CONFORM TO ANSI/AWS D1.4-11. USE LOW HYDROGEN E-70 SERIES ELECTRODES FOR WELDING OF REINFORCING BARS. CONTINUOUS INSPECTION IS REQUIRED OF ALL FIELD WELDING IN ACCORDANCE WITH C.B.C. CHAPTER 17.
6. THE SPECIFIED DIMENSIONS OF THE VERTICAL LEGS OF "L" DOWELS, WHOSE HORIZONTAL LEGS ARE CAST INTO A FOOTING OR SLAB CAST ON TOP OF EARTH, ARE BASED UPON THE SLAB THICKNESS AS SHOWN ON THE DRAWINGS. IF A SLAB IS POURED THICKER THAN SHOWN ON THE DRAWINGS, SUCH AS FOR THE SUBGRADE OCCURRING AT A LOWER ELEVATION THAN SHOWN, THE VERTICAL LEGS MUST BE FABRICATED TO A LONGER LENGTH OR THE HORIZONTAL TAILS MUST BE SUPPORTED ABOVE SUBGRADE HIGH ENOUGH TO PROVIDE THE SAME AMOUNT OF LAP LENGTH BETWEEN THE DOWEL AND
THE WALL VERTICAL REINFORCING.
CONCRETE NOTES
1. ALL CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-19 AND SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, UNLESS OTHERWISE NOTED ON THESE DRAWINGS OR IN THE PROJECT SPECIFICATIONS.
AGGREGATES SHALL CONFORM TO A.S.T.M. C33. AGGREGATES FOR LIGHTWEIGHT CONCRETE SHALL CONFORM TO A.S.T.M.
C330.
2. CEMENT FOR CONCRETE SHALL BE TYPE II OR TYPE V PORTLAND CEMENT CONFORMING TO A.S.T.M. C150.
3. CONCRETE COVER FOR REINFORCING BARS SHALL BE:
CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH = 3"
EXPOSED TO EARTH OR WEATHER: NO. 6 THROUGH NO. 18 BARS = 2"
NO. 5 BARS AND SMALLER = 1 1/2"
4. DRYPACK SHALL BE 1 PART CEMENT AND 3 PARTS SAND (BY VOLUME).
5. NO PIPES OR DUCTS SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED. SEE MECHANICAL, PROCESS AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES THROUGH WALLS AND FLOORS.
6. THE LOCATION OF ALL CONSTRUCTION JOINTS NOT SPECIFICALLY NOTED OR SHOWN SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
7. "ROUGHENED SURFACES", WHERE SPECIFIED ON THE DRAWINGS, SHALL BE MECHANICALLY ROUGHENED SUCH THAT A 1/4" AMPLITUDE (±) IS ACHIEVED BETWEEN HIGH AND LOW SPOTS OF THE ROUGHENED SURFACE. THE SURFACE SHALL BE CLEAN
AND FREE OF LAITANCE.
8. BOTH FACES OF CONCRETE WALLS, EDGES OF CONCRETE FOUNDATIONS, AND OTHER FORMED CONCRETE SURFACES WHERE THE SPECIFIED CONCRETE COVER IS 2 INCHES, SHALL BE PLACED AGAINST FORMWORK WHICH COMPLIES WITH THE PROJECT SPECIFICATIONS. CONCRETE FOR THESE ELEMENTS SHALL NOT BE CAST AGAINST EARTH.
9. IF NOT SPECIFIED ON DRAWINGS, ALL JOINTS SHOWN ON STRUCTURAL DRAWINGS SHALL BE ROUGHENED. SEE NOTE 7 FOR
MORE INFORMATION.
10. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS.
STRUCTURAL STEEL NOTES
1. ALL WIDE FLANGE MEMBERS, CHANNELS, AND ANGLES SHALL BE IN ACCORDANCE WITH A.S.T.M. A-992. ALL OTHER STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE ASTM A36 UNLESS NOTED OTHERWISE. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. SPECIAL INSPECTION SHALL BE PROVIDED FOR ALL STRUCTURAL STEEL IN ACCORDANCE WITH CBC SECTION 1705.2.1, UNLESS FABRICATION IS PERFORMED ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION, IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND SECTION 1704.2.5.1 OF THE 2019 CBC. AT THE COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE CITY BUILDING OFFICIAL (OR OWNER IF THE PROJECT IS NOT UNDER THE JURISDICTION OF A BUILDING DEPARTMENT) AND TO THE ENGINEER STATING THAT THE WORK WAS
PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
2. HSS STEEL RECTANGULAR AND ROUND SHALL CONFORM TO A.S.T.M. A500, GRADE C OR BETTER, UNLESS NOTED
OTHERWISE.
3. STEEL PIPES SHALL CONFORM TO A.S.T.M. A53 GR. B.
4. BOLTS SHALL CONFORM TO A.S.T.M. F3125 GR. A325 OR BETTER, UNLESS NOTED OTHERWISE.
5. HOLES FOR BOLTS IN STEEL SHALL BE OF SAME DIAMETER AS BOLT +1/16" MAXIMUM.
6. ALL WELDING SHALL BE PERFORMED BY A CERTIFIED WELDER IN A FABRICATION SHOP REGISTERED AND APPROVED IN ACCORDANCE WITH NOTE 1 ABOVE. CONTINUOUS INSPECTION IS REQUIRED OF ALL FIELD WELDING IN ACCORDANCE WITH
AWS D1.1.
7. NO STRUCTURAL STEEL MEMBER SHALL BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED AND APPROVED
BY STRUCTURAL ENGINEER.
8. STAINLESS STEEL SHALL CONFORM TO A.S.T.M. A276/A.I.S.I. 316. STAINLESS STEEL BOLTS SHALL CONFORM TO A.S.T.M. F593.
STAINLESS STEEL NUTS SHALL CONFORM TO A.S.T.M. F594.
9. WELDING OF STAINLESS STEEL SHALL CONFORM TO STRUCTURAL WELDING CODE - STAINLESS STEEL, ANSI/AWS D1.6-07.
10. WHERE SPECIFIED, USE OF HIGH-STRENGTH BOLTS SHALL CONFORM TO THE PROVISIONS OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING A.S.T.M. A325 OR A490 BOLTS" APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION (RCSC). SPECIAL INSPECTION OF HIGH-STRENGTH BOLT CONNECTIONS IS
REQUIRED.
11. ALL NON-STAINLESS STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123 OR A153, AS APPLICABLE. REPAIR OF DAMAGED GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A780. ALL OTHER
NON-STAINLESS STEEL SHALL BE COATED WITH TWO COATS OF SHOP APPLIED PRIMER
12. WELDING EQUIPMENT SHALL BE CHECKED PRIOR TO WELDING AS REQUIRED BY AISC 360-16 TABLE N5.4-1.
POST-INSTALLED ANCHORS (HILTI)
1. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ICC REPORT.
2. SPECIAL INSPECTION SHALL BE PROVIDED DURING ANCHOR INSTALLATION. SEE SHEET S-002.
3. ALTERNATIVE ANCHOR PRODUCT MAY BE SUBMITTED TO THE ENGINEER FOR APPROVAL, PROVIDED THAT IT HAS A CURRENT
I.C.C. EVALUATION REPORT APPROVAL.
4. ALL ABANDONED HOLES SHALL BE FILLED WITH A DRYPACK GROUT A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5,000 PSI.
THE FILLED HOLE(S) SHALL BE PREPARED AND CLEANED AS REQUIRED BY THE GROUT MANUFACTURER.
5. LOCATE EXISTING REINFORCING USING A NON-DESTRUCTIVE METHOD (PACHOMETER OR OTHER), PRIOR TO STEEL FABRICATION OF THE AFFECTED COMPONENTS AND PRIOR TO DRILLING HOLES FOR ANCHORS. MAINTAIN A MINIMUM CLEARANCE OF 1" BETWEEN THE REINFORCEMENT AND THE ANCHOR. NOTIFY ENGINEER IF ADHESIVE ANCHORS CANNOT BE INSTALLED DUE TO REBAR INTERFERENCE(S) SO STRUCTURAL STEEL DETAILING SHOWN HEREON CAN BE MODIFIED TO
ACCOMMODATE.
FLARE STACK AND AIR COMBUSTION BLOWER EQUIPMENT NOTES
1. ANCHORAGE FOR TRAILERS, CONTAINERS, TANKS AND EQUIPMENT NOT SPECIFICALLY DETAILED IN THESE DRAWINGS SHALL BE DESIGNED AND PROVIDED BY THE GENERAL CONTRACTOR OR THE TANK OR EQUIPMENT MANUFACTURER. THE CALCULATIONS AND SHOP DRAWINGS FOR THE ANCHORAGE SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION. ALL CALCULATIONS AND ANCHORAGE SHOP DRAWINGS SHALL BE SIGNED, SEALED AND DATED BY A
REGISTERED CIVIL OR STRUCTURAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA.
A. FLARE STACK
WEIGHT = 30,000 LBS
CENTER OF GRAVITY = 19' - 0 1/2" (FROM BOT OF BASE PLATE)
B. COMBUSTION AIR BLOWER
WEIGHT = 3,000 LBS
CENTER OF GRAVITY = 3'-6 1/2" (FROM BOT OF BASE PLATE)
C. BLOWER SKID (GAS HANDLING SYSTEM)
WEIGHT = 46,000 LBS
CENTER OF GRAVITY = 3'-3 9/16" (FROM BOT OF BASE PLATE)
D. COMPRESSOR SKID (GAS HANDLING SYSTEM)
WEIGHT = 2,500 LBS
CENTER OF GRAVITY = 2'-3" (FROM BOT OF BASE PLATE)
2. THE DESIGN OF ANY EQUIPMENT NOT SPECIFICALLY DETAILED SHALL BE DONE IN ACCORDANCE TO THE 2022 CALIFORNIA BUILDING CODE AND THE ASCE 7-16. TANKS OR EQUIPMENT MOUNTED TO A CONCRETE FOUNDATION SHALL BE DESIGNED AS A "NONBUILDING STRUCTURE" PER CHAPTER 15 OF ASCE 7-16. REFER TO DESIGN CRITERIA SECTION FOR
ADDITIONAL INFORMATION.
3. CAST-IN-PLACE SHALL MEET ALL OF THE REQUIREMENTS OF ACI 318-19 CHAPTER 17, INCLUDING SEISMIC LOADING AND DUCTILE FAILURE REQUIREMENTS FOR TANKS ONLY. THE EMBEDMENT OF ANCHORS IN CONCRETE SHALL BE AS MEASURED FROM THE TOP OF THE FOUNDATION. THE PORTION OF ANCHORS IN CONCRETE HOUSEKEEPING PADS, WHERE SUCH PADS OCCUR, SHALL NOT BE INCLUDED IN THE EMBEDMENT OF THE ANCHORS.
4. CAST-IN-PLACE ANCHORS SHALL BE H.D.G. STEEL CAST-IN-PLACE ANCHOR BOLTS OR POST-INSTALLED ADHESIVE ANCHORS. EXPANSION ANCHORS MAY NOT BE USED FOR TANK ANCHORAGE TO CONCRETE.
DESIGN CRITERIA
DESIGN CODES AND REFERENCES:
- 2022 CALIFORNIA BUILDING CODE
- ASCE 7-16, MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES
- AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS 15TH EDITION
- ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
SEISMIC DESIGN PARAMETERS:
LOCATION: LAT.: 36.989126, LONG.: -122.100983
SITE CLASS: C
SEISMIC DESIGN CATEGORY: D
Fa = 1.20 Fv = 1.40 Ss = 1.650 S1 = 0.625 Sds = 1.320 Sd1 = 0.583
FLARE STACK:
R = 2 (STEEL CHIMNEYS AND STACKS, ASCE 7-16 TABLE 15.4-2)
Ω = 2
RISK CATEGORY = II
Ie = 1.0 Cs = 0.47
COMBUSTION AIR BLOWER:
R = 1.25 (ALL OTHER SELF-SUPPORTING STRUCTURES, TANKS, AND VESSELS, ASCE 7-16 TABLE 15.4-2) Ω = 2.00
RISK CATEGORY = II
Ie = 1.0 Cs = 1.06
BLOWER SKID (GAS HANDLING SYSTEM) AND COMPRESSOR SKID:
R = 1.25 (ALL OTHER SELF-SUPPORTING STRUCTURES, ASCE 7-16, TABLE 15.4-2)
Ω = 2.00 Ie = 1.0 Cs = 1.06
PIPE SUPPORTS:
R = 1.25(ALL OTHER SELF-SUPPORTING STRUCTURES, ASCE 7-16, TABLE 15.4-2)
Ω = 2.00 Ie = 1.00 Cs = 1.06
WIND LOAD DESIGN PARAMETERS:
RISK CATEGORY = II
ULTIMATE DESIGN WIND SPEED = 92 MPH
EXPOSURE CATEGORY = C
SOIL DESIGN PARAMETERS: (GEOTECH REPORT #BAS 23-212E: "NEW FLARE STATION BY TETRA TECH, DATED DECEMBER 4, 2024)
(i) MAT FOUNDATIONS
ALLOWABLE BEARING CAPACITY (NET): 1,200 PSF (1/3 INCREASE FOR TRANSIENT LOADS)
COEFFICIENT OF FRICTION: 0.3
UNIT MODULES OF SUBGRADE REACTION: 200 PCI (TO BE ADJUSTED BASED ON MAT SIZE)
PASSIVE RESISTANCE: (NEGLECT UPPER 12 INCHES) 180 PSF/FT (1/3 INCREASE FOR TRANSIENT LOADS)
(ii) RETAINING WALL AND FOUNDATIONS
ALLOWABLE BEARING CAPACITY (NET): 2,500 PSF (1/3 INCREASE FOR TRANSIENT LOADS)
COEFFICIENT OF FRICTION: 0.3
PASSIVE RESISTANCE: (NEGLECT UPPER 12 INCHES) 180 PSF/FT (1/3 INCREASE FOR TRANSIENT LOADS) LATERAL ACTIVE PRESSURE: 59z + 0.47 x Q
(iii) EMBEDDED POSTS AND PIPE SUPPORTS
ALLOWABLE BEARING CAPACITY (NET): 1,500 SF
PASSIVE RESISTANCE: (NEGLECT UPPER 12 INCHES) 150 PSF/FT
300 PFS/FT (FOUND NOT AFFECTED BY 0.5" MOVEMENT)
ANCHOR BOLT
AMERICAN CONCRETE
INSTITUTION
AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ARCHITECT
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AMERICAN WELDING
SOCIETY
BOTTOM
CALIFORNIA BUILDING
CODE
CAST-IN-DRILLED HOLE
PILE
CONSTRUCTION JOINT
CLEAR
CONCRETE
CONSTRUCTION
CONTINUOUS
CONCRETE REINFORCING
STEEL INSTITUTE
DIAMETER
EXISTING
EACH
EACH FACE
ELEVATION
ELEVATION
EQUAL
EACH WAY
EXISTING
FOUNDATION
FINISH FLOOR
FINISH GRADE
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GENERAL
HIGH
HOT DIP GALVANIZED
HORIZONTAL
HOLLOW STEEL SECTION
HEIGHT
INTERNATIONAL CODE
COUNCIL
INVERT
KIPS
KIPS PER SQUARE INCH
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
NUMBER
NOT TO SCALE
ON CENTER
POUNDS PER CUBIC FOOT
POUNDS PER SQUARE
FOOT
POUNDS PER SQUARE
INCH
REINFORCING
REQUIRED
SQUARE FEET
SIMILAR
SPECIFICATIONS
SHEET METAL SCREW
SQUARE
STRUCTURAL
TOP OF
TOP OF FOOTING
TOP OF STEEL
TYPICAL
UNLESS NOTED
OTHERWISE
VERTICAL
WIDE
WITH
WIDE FLANGE
WORKING POINT
AT
AND
NUMBER
A.B.
A.C.I.
A.I.S.C.
ARCH.
A.S.T.M.
A.W.S.
BTM.
C.B.C.
CIDH
C/J
CLR.
CONC.
CONST.
CONT.
C.R.S.I.
DIA.
(E)
EA.
E.F.
EL.
ELEV.
EQ.
E.W.
EXIST.
FDN.
F.F.
F.G.
GA.
GALV.
G.C.
GEN.
H H.D.G.
HORIZ.
HSS
HT.
ICC
INV
K
KSI
MAX.
MECH.
MFR.
MIN.
No.
N.T.S.
O.C.
PCF
PSF
PSI
REINF.
REQ'D.
SF
SIM.
SPECS.
S.M.S.
SQ.
STRUCT.
T.O.
T.O.F.
T.O.S.
TYP.
U.N.O.
VERT.
W w/
WF
W.P.
STRUCTURAL ABBREVIATIONS
S-001STRUCTURAL NOTES
Fi Oe
: X :?P
R O
JE
C
TS
?S
AN
TA
C R
U Z?
7-
-4
- S aQ Wa
C
UX
z Lo w -N
O x
FO
aU e?
PU
oM eF
W D Ua w iQ
Js ?1
-2
4-
BS
1B
ST
R U
C
TU
R
AL
N O
TE
S.
dw J
L a\ oX W:
S-
U se U:
C H
EL
SE
A.
EV
AN
S
Ja Q
, 2
- 5 :5
9S P
IS
S
U E
D F
O R
B
ID
D
IN
G
N O
T F
O R
C O
N S
T R
U C
T
IO
N
01-28-2026
REV REVISION DESCRIPTION
DESIGNED BY : LCM
DRAWN BY : GSW
DATE :
CITY OF SANTA CRUZ PUBLIC WORKS DEPARTMENT
DATE
SHEET
CHECKED BY : CME
APPROVED BY : PJS
SANTA CRUZ RRF
ENCLOSED FLARE STATION INSTALLATION PROJECT
MJB
STEEL CONSTRUCTION (STRUCTURAL STEEL):
P - INSPECT THESE ITEMS ON A PERIODIC BASIS. OPERATIONS NEED NOT BE DELAYED PENDING
THESE INSPECTIONS
C - INSPECT THESE ITEMS ON A CONTINUOUS BASIS
1. INSPECTION TASKS PRIOR TO WELDING
A. WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS
B. WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE
C. MANUFACTURERS CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
D. MATERIAL IDENTIFICATION (TYPE/GRADE)
E. WELDER IDENTIFICATION SYSTEM
F. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
- JOINT PREPARATION
- DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
- CLEANLINESS (CONDITION OF STEEL SURFACES)
- TACKING (TACK WELD QUALITY AND LOCATION)
- BACKING TYPE AND FIT (IF APPLICABLE)
G. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K- JOINTS WITHOUT BACKING
(INCLUDING JOINT GEOMETRY)
- JOINT PREPARATIONS
- DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
- CLEANLINESS (CONDITION OF STEEL SURFACES)
- TACKING (TACK WELD QUALITY AND LOCATION)
H. CONFIGURATION AND FINISH OF ACCESS HOLES
I. FIT-UP OF FILLET WELDS
- DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
- CLEANLINESS (CONDITION OF STEEL SURFACES)
- TACKING (TACK WELD QUALITY AND LOCATION)
2. INSPECTION TASKS DURING WELDING
A. CONTROL AND HANDLING OF WELDING CONSUMABLES
- PACKAGING
- EXPOSURE CONTROL
B. NO WELDING OVER CRACKED TACK WELDS
C. ENVIRONMENTAL CONDITIONS
- WIND SPEED WITHIN LIMITS
- PRECIPITATION AND TEMPERATURE
D. WPS FOLLOWED
- SETTINGS ON WELDING EQUIPMENT
- TRAVEL SPEED
- SELECTED WELDING MATERIALS
- SHIELDING GAS TYPE/FLOW RATE
- PREHEAT APPLIED
- INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
- PROPER POSITION (F, V, H, OH)
E. WELDING TECHNIQUES
- INTERPASS AND FINAL CLEANING
- EACH PASS WITHIN PROFILE LIMITATIONS
- EACH PASS MEETS QUALITY REQUIREMENTS
F. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
3. INSPECTION TASKS AFTER WELDING
A. WELDS CLEANED
B. SIZE, LENGTH AND LOCATION OF WELDS
C. WELDS MEET VISUAL ACCEPTANCE CRITERIA
- CRACK PROHIBITION
- WELD/BASE-METAL FUSION
- CRATER CROSS SECTION
- WELD PROFILES
- WELD SIZE
- UNDERCUT
- POROSITY
D. ARC STRIKES
E. K-AREA
- WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS
HAS BEEN PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA
FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD
F. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES
- AFTER ROLLED HEAVY SHAPES (SEE AISC SECTION A3.1C) AND BUILT-UP SHAPES
(SEE AISC SECTION A3.1D) ARE WELDED, VISUALLY INSPECT THE WELD ACCESS
HOLE FOR CRACKS
G. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)
H. REPAIR ACTIVITIES
I. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER
J. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR
SPECIAL INSPECTIONS
REQUIRED ( YES NO)
P C N/A
CONCRETE CONSTRUCTION:
1. INSPECT REINFORCMENT, INCLUDING PRESTRESSING
TENDONS, AND PLACEMENT
2. REINFORCING BAR WELDING:
A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706
B. INSPECT SINGLE-PASS FILLET WELD, MAXIMUM 5/16"; AND
C. INSPECT ALL OTHER WELDS.
3. INSPECTION OF ANCHORS CAST IN CONCRETE.
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .