This is a Scope of Work document and related state and local contract opportunity for the City of Pembroke Pines, Florida, involving epoxy flooring replacement at Charles F. Dodge City Hall. The project requires installation of a Sherwin-Williams Resuflor Deco Flake BC high-performance resinous flooring system with a nominal thickness of 20-30 mils in the Great Hall, including complete demolition, surface preparation, moisture testing, primer application, topcoating, sealant application, and slip-resistant finish. The contractor must submit product data, installer certificates of qualification, material certificates, maintenance data, color and texture samples on rigid backing (two 6" X 6" samples minimum), and a product schedule prior to installation. A mandatory pre-bid meeting is scheduled for March 3, 2026 at 10:00 a.m., with questions due by March 17, 2026 at 6:00 p.m. and final answers issued by March 23, 2026. Electronic bids are due by 2:00 p.m. on March 31, 2026, with public bid opening at 2:30 p.m. the same day. A pre-installation conference and full-thickness mockups on a 16 square-foot floor area must be approved by the Architect before proceeding. The contractor must have minimum qualifications of five years of experience and must provide both a seven-year workmanship labor warranty and a seven-year product warranty from the manufacturer. The City Commission will recommend award on May 6, 2026, with Notice to Proceed issued by May 20, 2026. Work is restricted to weekends and Thursday evenings after 5:00 p.m. until Sunday at 11:00 p.m., with a mandatory performance window from July 30, 2026 through August 30, 2026, and must be completed within 25 calendar days from issuance of the Notice to Proceed.

The estimated project cost is $150,000. The contractor must provide comprehensive general liability insurance with limits of $1,000,000 per occurrence and $2,000,000 aggregate, workers' compensation coverage, auto liability insurance, and $2,000,000 umbrella/excess liability coverage, with the City named as additional insured, along with two separate payment and performance bonds each equal to 100 percent of the contract price. A proposal security of $10,000 or 5 percent of the total bid amount (whichever is less) is required from all bidders. The project is subject to federal Davis-Bacon prevailing wage requirements and HUD Section 3 provisions, requiring contractors and all subcontractors to comply with prevailing wage standards for skilled trades as determined by the U.S. Department of Labor for Broward County, Florida, with mandatory weekly certified payroll reporting using DOL Form WH-347. Contractors must ensure that at least 25 percent of total project hours are worked by Section 3 workers (low- and very low-income residents) and 5 percent by Targeted Section 3 workers. The City will waive all City-related permit and license fees, with any state or county fees covered through an Owner's Contingency allowance. Liquidated damages are assessed at $964 per day for failure to meet start or completion dates. No grant or federal funding is directly applicable, and there are no identified set-asides or restrictions limiting responses to disadvantaged enterprises, minority-owned businesses, or women-owned businesses.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RESINOUS FLOORING 096723 - 1

DIVISION 9 - FINISHES

SECTION 096723 – RESINOUS FLOORING

PART 1 - GENERAL

1.1 SUMMARY

A. This Section includes:

1. High-performance resinous flooring systems.

1.2 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Installer Certificates for Qualification: Signed by manufacturer stating that installers comply with specified requirements.

C. Material Certificates: For each resinous flooring component, from manufacturer.

D. Maintenance Data: For maintenance manuals.

E. Samples: Submit two 6” X 6” samples of each resinous flooring system applied to a rigid backing.

Provide sample which is a true representation of proposed field applied finish. Provide sample color and texture for approval from Owner in writing or approved by General Contractor prior to installation.

F. Product Schedule: For resinous flooring.

1.3 QUALITY ASSURANCE

A. Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation of flooring systems required for this Project.

1. Engage an installer who is approved in writing by resinous flooring manufacturer as qualified to apply resinous flooring systems indicated.

2. Installer Letter of Qualification: Installer to provide letter stating that they have been in business for at least 5 years and listing 5 projects in the last 2 years of similar scope. For each project provide: project name, location, date of installation, contact information, size of project, and manufacturer of materials with system information.

B. Source Limitations: Obtain primary resinous flooring materials, including primers, resins, hardening agents, grouting coats, and topcoats, from single source from single manufacturer. Provide secondary materials, including patching and fill material, joint sealant, and repair materials, of type and from source recommended by manufacturer of primary materials.

C. Pre-installation Conference: Conduct conference at Project site before work and mockups begin.

D. Mockups: Apply mockups to verify selections made under sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution. Do not cover up mockup area.

1. Apply full-thickness mockups on 16 square foot floor area selected by Architect.

2. Finish surfaces for verification of products, color, texture, and sheen.

3. Simulate finished lighting conditions for Architect's review of mockups.

4. Approved mockups may become part of the completed Work if undisturbed at time of Substantial

Completion.

5. Mockup shall demonstrate desired slip resistance for review and approval by Owner’s representative in writing.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Deliver materials in original packages and containers, with seals unbroken, bearing manufacturer's labels indicating brand name and directions for storage and mixing with other components.

1. Maintain containers in clean condition, free of foreign materials and residue.

2. Remove rags and waste from storage areas daily.

1.5 PROJECT CONDITIONS

RESINOUS FLOORING 096723 - 2

A. Environmental Limitations: Comply with resinous flooring manufacturer's written instructions for substrate temperature, ambient temperature, moisture, ventilation, and other conditions affecting resinous flooring application.

B. Lighting: Provide permanent lighting or, if permanent lighting is not in place, simulate permanent lighting conditions during resinous flooring application.

C. Close spaces to traffic during resinous flooring application and for not less than 24 hours after application unless manufacturer recommends a longer period.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products by:

1. The Sherwin Williams Company, Cleveland, OH. swflooring@sherwin.com

B. Resuflor Deco Flake BC, 20-30 mils nominal thickness.

1. Primer: Resuprime 3579 at 200-300 sq. ft. per gallon.

2. Body Coat: Resuflor 3746 at 200-300 sq. ft. per gallon.

3. Broadcast: Decorative Flakes 6750 or 6755 to excess at 100-200 lbs. per 1,000 sq. ft.

4. Grout Coat: Resuflor 3746 at 160-250 sq. ft. per gallon.

5. Seal Coat: Resutile 4686 at 250-400 sq. ft. per gallon.

2.2 MATERIALS

A. VOC Content of Resinous Flooring: Provide resinous flooring systems, for use inside the weatherproofing system, that comply with the following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA Method 24)].

1. Resinous Flooring: 100 g/L.

2.3 HIGH-PERFORMANCE RESINOUS FLOORING

A. Resinous Flooring: Abrasion-, impact- and chemical-resistant, high-performance, resin-based, monolithic floor surfacing designed to produce a seamless floor.

B. System Characteristics:

1. Color and Pattern: As indicated from manufacturers listed above.

2. Slip Resistance: Provide slip resistant finish.

PART 3 - EXECUTION

3.1 PREPARATION

A. Inspection: Prior to commencing Work, thoroughly examine all underlying and adjoining work, surfaces and conditions upon which Work is in any way dependent for perfect results. Report all conditions which affect Work. No "waiver of responsibility" for incomplete, inadequate or defective underlaying and adjoining work, surfaces and conditions will be considered, unless notice of such unsatisfactory conditions has been filed and agreed to in writing before Work begins. Commencement of Work constitutes acceptance of surfaces.

B. Surface Preparation: Remove all surface contamination, loose or weakly adherent particles, laitance, grease, oil, curing compounds, paint, dust and debris by blast track method or approved mechanical means (acid etch not allowed). If surface is questionable, try a test patch. Create a minimum surface profile for the system specified in accordance with the methods described in ICRI No. 03732 to achieve profile numbers as follows:

mailto:swflooring@sherwin.com

RESINOUS FLOORING 096723 - 3

C.

1. Thin film, to 10 mils CSP-1 to CSP-3

2. Thin and medium films, 10 to 40 mils CSP-3 to CSP-5

3. Self-leveling mortars, to 3/16” CSP-4 to CSP-6

4. Mortars and laminates, to 1/4” or more CSP-5 to CSP-10

D. Verify that concrete substrates are dry and moisture-vapor emissions are within acceptable levels according to manufacturer's written instructions.

1. Moisture Testing: Perform tests indicated below.

a. Calcium Chloride Test: Perform anhydrous calcium chloride test per ASTM F 1869.

Proceed with installation only after substrates have maximum moisture-vapor-emission rate of 3 lbs. of water/1000 sq. ft. in 24 hours. Perform tests so that each test area does not exceed 1000 sq. ft. and perform 3 tests for the first 1000 sq. ft. and one additional test for every additional 1000 sq ft.

b. In-Situ Probe Test: Perform relative-humidity test using in-situ probes per ASTM F 2170.

Proceed with installation only after substrates have a maximum 75 percent relative-humidity-level measurement.

3.2 ENVIRONMENTAL CONDITIONS

A. All applicators and all other personnel in the area of the RF installation shall take all required and necessary safety precautions. All manufacturers’ installation instructions shall be implicitly instructions shall be implicitly followed.

B. Repair damaged and deteriorated concrete according to resinous flooring manufacturer's written instructions.

C. Alkalinity and Adhesion Testing: Verify that concrete substrates have pH within acceptable range.

Perform tests recommended by manufacturer. Proceed with application only after substrates pass testing.

D. Resinous Materials: Mix components and prepare materials according to resinous flooring manufacturer's written instructions.

E. Use patching and fill material to fill holes and depressions in substrates according to manufacturer's written instructions.

F. Treat control joints and other nonmoving substrate cracks to prevent cracks from reflecting through resinous flooring according to manufacturer's written instructions.

3.3 APPLICATIONS

A. Install resinous floor over properly prepared concrete surface in strict accordance with the manufacturer's directions.

1. Install the primer and/or base coats over thoroughly cleaned and prepared concrete.

2. Install topcoat over flooring after excess aggregate has been removed.

3. Maintain a slab temperature of 60°F to 80°F for 24 hours minimum before applying floor topping, or as instructed by manufacturer.

B. Apply components of resinous flooring system according to manufacturer's written instructions to produce a uniform, monolithic wearing surface of thickness indicated.

1. Coordinate application of components to provide optimum adhesion of resinous flooring system to substrate, and optimum intercoat adhesion.

2. Cure resinous flooring components according to manufacturer's written instructions. Prevent contamination during application and curing processes.

3. At substrate expansion and isolation joints, comply with resinous flooring manufacturer's written instructions.

C. Sealant: Saw cut resinous floor topping at expansion joints in concrete slab. Fill sawcuts with sealant prior to final seal coat application. Follow manufacturer’s written recommendations.

D. Apply primer over prepared substrate at manufacturer's recommended spreading rate.

E. Slip Resistant Finish: Provide grit for slip resistance.

F. Apply topcoats in number indicated for flooring system and at spreading rates recommended in writing by manufacturer.

RESINOUS FLOORING 096723 - 4

3.4 COMPLETED WORK

A. Cleaning: Upon completion of the Work, clean up and remove from the premises surplus materials, tools, appliances, empty cans, cartons and rubbish resulting from the Work. Clean off all spattering and drippings, and all resulting stains.

B. Protection: Protect Work in accordance with manufacturer's directions from damage and wear during the remainder of the construction period. Use protective methods and materials, including temporary covering, recommended in writing by resinous flooring manufacturer.

C. Contractor shall insure that coating is protected from any traffic until it is fully cured to the satisfaction of the coating manufacturer.

END OF SECTION 096723

DESIGNED TO PERFORM sherwin-williams.com/resin-flooring

SYSTEM OVERVIEW

RESUFLOR™ DECO

FLAKE BC

Sherwin-Williams Resuflor Deco Flake BC is a mosaic pattern floor covering. Vinyl chips are incorporated in a clear or pigmented epoxy and sealed with a clear, high-gloss, polyurethane finish.

Its innovative base chemistry also provides tough chemical resistant protection.

Broadcast

Grout/Seal Coat

Primer 2

Base Coat1

BENEFITS

• Aesthetically pleasing appearance

• Limitless color options

• Seamless

• Chemical- and stain-resistant

• High-gloss finish

• LEED® v4 compliant

USES

• Nursing homes and healthcare facilities

• Clean rooms and pharmaceuticals

• Office buildings

• Locker and restrooms

• Cafeterias

10-16-24_acc Accessibility Statement sherwin-williams.com/resin-flooring https://accessibility.sherwin-williams.com/

RESUFLOR™ DECO FLAKE BC

SYSTEM OVERVIEW

©2024 The Sherwin-Williams Company High Performance Flooring

HPF-1697217-12 10/24

United States & Canada sherwin-williams.com/resin-flooring swflooring@sherwin.com

THE SHERWIN-WILLIAMS DIFFERENCE

Sherwin-Williams High Performance Flooring delivers world-class industry subject matter expertise, unparalleled technical and specification service, and unmatched regional commercial team support to our customers around the globe.

ABOUT CHEMICAL RESISTANCE

FEATURED COLORS

TYPICAL PHYSICAL PROPERTIES

Sherwin-Williams High Performance Flooring offers a broad range of systems to accommodate nearly every industrial, commercial and institutional setting. Each flooring system includes a standard chemical resistant topcoat or surface proven to perform under typical conditions.

Important considerations:

• The combination of cleaning solutions, sanitizing chemicals, processing substances and products found in any operational setting is unique.

• Knowing exactly which materials are present – as well as their concentrations and typical exposure times before cleanup – is critical for proper flooring system selection.

• During the specification process, a flooring system’s standard chemical resistant topcoat may get replaced with one better suited to unique facility conditions.

The ability of a flooring system to perform as designed relies heavily on proper selection. Matching each use case with the right chemical resistant flooring is key to a having a facility looking great and functioning at peak level over the long term.

See our Chemical Resistance Guide and other technical resources on our website. Connect with a Sherwin-Williams High Performance Flooring expert for help with specifying an optimal flooring system for your facility.

Property Result

Abrasion Resistance ASTM D 4060, CS-17 Wheel, 1,000 cycles

5.1 mgs lost

Flexural Strength ASTM C 580 10,000 psi

Adhesion

ACI 503R

300 psi concrete failure

Flammability Self-extinguishing over concrete

Impact Resistance

MIL-D-3134J

Direct, inch pound greater than 160, passes reverse, inch pound greater than 80, passes

Resistance to Elevated Temperatures

MIL-D-3134J

No slip or flow at required temperature of 158°F

ASTM C = Mortar System ASTM D = Resin only

Unlimited standard and custom blends available. Please see Deco Flake Color Cards for the extensive collection of standard blends or use our Flooring Visualizer Tool to create your own custom blend at floorvisualizer.sherwin-williams.com. This reproduction approximates the actual color. Factors such as the type of product, degree of gloss, texture, size and shape of area, lighting, heat or method of application may cause color variance. Contact your Sherwin-Williams representative for details.

Flaxseed

Chinchilla

Ocelot

Limestone

Almond Milk

Greyhound

Agave

Black Bean

Kingsnake

Speckled Ash

Korat

Moon

COLOR CARD

United States & Canada sherwin-williams.com/resin-flooring swflooring@sherwin.com

©2021 The Sherwin-Williams Company High Performance Flooring

PM-382294-CC 12/21

DECO FLAKE – 1/4" FLAKE

RESILIENT DECORATIVE FLOORING

Deco Flake systems combine multi-colored vinyl chips with resin to bring depth and interest to floor designs.

The chips can be fully broadcast or lightly sprinkled as an accent. These affordable, attractive and customizable resinous floor solutions are ideal for educational, healthcare, retail and other commercial environments.

COOL BLENDS

This reproduction approximates the actual color. Factors such as the type of product, degree of gloss, texture, size and shape of area, lighting, heat, or method of application may cause color variance. Substituting other manufacturers’ colors may not be representative of our blends. Contact your Sherwin-Williams representative for details.

Sapphire Velvet Celestial

Modern CamoSnowy Blizzard Star SeekerPebbled Path

Crashing Wave Crescent Moon Eclipse Evening

Blue Shadow Rebel Blue sherwin-williams.com/resin-flooring swflooring@sherwin.com

©2021 The Sherwin-Williams Company High Performance Flooring

PM-382294-CC 12/21

DECO FLAKE – 1/4" FLAKE

RESILIENT DECORATIVE FLOORING

WARM BLENDS

This reproduction approximates the actual color. Factors such as the type of product, degree of gloss, texture, size and shape of area, lighting, heat, or method of application may cause color variance. Substituting other manufacturers’ colors may not be representative of our blends. Contact your Sherwin-Williams representative for details.

River RockDesert Mirage Milky Way Hickory

Pyrite Velvet Feather Ground Hazelnut Mocha

Moon

Husky Gray Gray Parrot Black Diamond Castlerock

Limestone

Kiwi SkinMoose PretzelFlaxseed

Ocelot Burnt WoodAlmond Milk Plover

COLOR CARD

Chinchilla Mountain Fog

United States & Canada sherwin-williams.com/resin-flooring coatings@sherwin.com

©2025 The Sherwin-Williams Company High Performance Flooring

PM-382294-CC 01/25

This reproduction approximates the actual color. Factors such as the type of product, degree of gloss, texture, size and shape of area, lighting, heat, or method of application may cause color variance. Substituting other manufacturers’ colors may not be representative of our blends. Contact your Sherwin-Williams representative for details.

DECO FLAKE – 1/4" FLAKE

RESILIENT DECORATIVE FLOORING

Deco Flake systems combine multi-colored vinyl chips with resin to bring depth and interest to floor designs.

The chips can be fully broadcast or lightly sprinkled as an accent. These affordable, attractive and customizable resinous floor solutions are ideal for educational, healthcare, retail and other commercial environments.

sherwin-williams.com/resin-flooring coatings@sherwin.com

©2025 The Sherwin-Williams Company High Performance Flooring

PM-382294-CC 01/25

This reproduction approximates the actual color. Factors such as the type of product, degree of gloss, texture, size and shape of area, lighting, heat, or method of application may cause color variance. Substituting other manufacturers’ colors may not be representative of our blends. Contact your Sherwin-Williams representative for details.

Bottlenose

Agave Siltstone Korat Rhino

Gneiss

Black QuinoaKingsnake Speckled AshCherry Cordial

Grayhound Black BeanGray Squirrel Mackerel

Meteorite Tungsten

DECO FLAKE – 1/4" FLAKE

RESILIENT DECORATIVE FLOORING

RESUFLOR™ DECO FLAKE BC

The following information is to be used as a guideline for the installation of the Resuflor Deco Flake BC flooring system. Contact the Sherwin-Williams Technical Service Department for assistance prior to application.

APPLICATION INSTRUCTIONS

INSTALLATION

Sherwin-Williams materials shall only be installed by approved contractors. The following information is to be used as a guideline for the installation of the Resuflor Deco Flake BC. Contact the Sherwin-Williams Technical Service Department for assistance prior to application.

SURFACE PREPARATION – GENERAL

Sherwin-Williams systems can be applied to a variety of substrates if the substrate is properly prepared. Preparation of surfaces other than concrete will depend on the type of substrate, such as wood, concrete block, quarry tile, etc.

Should there be any questions regarding a specific substrate or condition, please contact the Sherwin-Williams Technical Service Department prior to starting the project. Refer to Surface Preparation Form G-1.

SURFACE PREPARATION – CONCRETE

Concrete surfaces shall be abrasive-blasted to remove all surface contaminants and laitance. The prepared concrete shall have a surface profile depending upon system selected. Refer to Form G-1.

After initial preparation has occurred, inspect the concrete for bug holes, voids, fins and other imperfections. Protrusions shall be ground smooth while voids shall be filled with a system compatible filler. For recommendations, consult the Sherwin-Williams Technical Service Department.

TEMPERATURE

Throughout the application process, substrate temperature should be 50°F-90°F. Substrate temperature must be at least 5°F above the dew point. Applications on concrete substrate should occur while temperature is falling to lessen offgassing. The material should not be applied in direct sunlight, if possible. Protect material from freezing prior to installation.

VOC MIXED APPLICATION STEP MATERIAL MIX RATIO THEORETICAL COVERAGE PACKAGING

<50 g/L Primer Resuflor™ 3579 2:1 200-300 sq ft/gal 3 or 15 gals

<100 g/L 0 Body Coat Resuflor™ 3746

6750/6755 Decorative Flake 2:1

To Excess 200-300 sq ft/gal

100-200 lbs/1,000 sq ft 3 or 15 gals

25 lbs

<100 g/L Grout Coat Resuflor 3746 2:1 160-250 sq ft/gal 3 or 15 gals

<50 g/L Seal Coat Resutile™ HTS 100 1:1 500 sq ft/gal 1, 2 or 5 gals

For additional topcoat options, consult the Sherwin-Williams Topcoat Selection Guide or contact your Sherwin-Williams Representative.

APPLICATION INFORMATION – SURFACE PREP PROFILE CSP 1-3

10-15-24_acc Accessibility Statement

GENERAL PRODUCT INFORMATION

PRIMER – RESULFOR™ 3579

MIXING AND APPLICATION

1. Add 2 parts 3579A (resin) to 1 part 3579B (hardener) by volume. Mix with low-speed drill and Jiffy® blade for three minutes until uniform. To ensure proper system cure and performance, strictly follow mix ratio recommendations.

2. 3579 May be applied via spray, roller or brush. Apply at a spread rate of 200-300 sq ft/gal, evenly, with no puddles. Coverage will vary depending upon porosity of the substrate and surface texture.

3. 3579 Application varies upon usage.

NOTE: epoxy materials may tend to blush at the surface, especially in humid environments. After the surface is primed and before installation of each subsequent coat, surface must Be examined for blush (a whitish greasy film and/or low gloss). The blush must be completely removed prior to recoating using warm detergent water or solvent wipe.

Epoxy materials will appear to be cured and dry to touch prior to full chemical cross linking. Allow epoxy to cure for 2-3 days prior to exposure to water or other chemicals for best performance.

BASE COAT – RESULFOR™ 3746

MIXING AND APPLICATION

1. Premix 3746A (resin) using a low-speed drill and Jiffy blade. Mix for one minute until uniform, exercising caution not to introduce air into the material.

2. Add 2 parts 3746A (resin) to 1 part 3746B (hardener) by volume. Mix with low-speed drill and Jiffy blade for three minutes until uniform. To ensure proper system cure and performance, strictly follow mix ratio recommendations.

3. Apply 3746 using a squeegee or trowel and back roll with a 1/4” nap roller at a spread rate of 200-300 sq ft/gal making sure of uniform coverage. Take care not to puddle materials and ensure even coverage.

4. Allow material to self-level 10-15 minutes. Begin evenly broadcasting 6750/6755 vinyl chips into wet resin much the same as grass seed is spread. Vinyl chips should be broadcast in such a way that the chips fall lightly into resin without causing the resin to move. Continue broadcasting to excess until the floor appears completely dry.

5. Allow to cure for 12 hours, sweep off excess vinyl chips with a stiff-bristled broom.

GROUT COAT – RESULFOR™ 3476

MIXING AND APPLICATION

1. Premix 3746A (resin) using a low-speed drill and Jiffy blade. Mix for one minute until uniform, exercising caution not to introduce air into the material.

2. Add 2 parts 3746A (resin) to 1 part 3746B (hardener) by volume. Mix with low-speed drill and Jiffy blade for three minutes until uniform. To ensure proper system cure and performance, strictly follow mix ratio recommendations.

3. Apply 3746 using a squeegee or trowel and backroll with a 1/4” nap roller at a spread rate of 160-250 sq ft/gal making sure of uniform coverage. Take care not to puddle materials and ensure even coverage.

4. Allow to cure before applying seal coat. (Cure times vary depending on environmental conditions.)

SEAL COAT – RESUTILE™ HTS 100

MIXING AND APPLICATION

1. Premix Part A for three minutes using a Jiffy mixer blade and slow speed drill. Note: Once opened, this material cannot be resealed for later use.

2. Pour Part C into Part A while mixing. Continue to mix and add Part B. Mix for three minutes being careful to not whip air into material. Pour into an application tray.

3. Apply Resutile HTS 100 at the rate of 500 sq ft/gal with a 3/8” (10 mm) nap roller. For proper appearance and development of physical properties, it is crucial that material is not to be applied above or below the rate. Dip the roller in the coating and lightly roll out excess in the application tray. Apply two 8-10 foot long paths on the floor, making one stroke left to right and one right to left.

RESUFLOR™ DECO FLAKE BC

APPLICATION INSTRUCTIONS

CLEANUP

Clean up mixing and application equipment immediately after use. Use toluene or xylene. Observe all fire and health precautions when handling or storing solvents.

SAFETY PRECAUTIONS

Refer to the SDS before use. Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams Representative for additional technical data and instructions.

MATERIAL STORAGE

Store materials in a temperature controlled environment (50°F-90°F) and out of direct sunlight. Keep resins, hardeners and solvents separated from each other and away from sources of ignition.

MAINTENANCE

Occasional inspection of the installed material and spot repair can prolong system life. For specific information, contact the Sherwin-Williams Technical Service Department.

DISCLAIMER

The information and recommendations set forth in this document are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication.

Consult sherwin-williams.com/resin-flooring to obtain the most recent Product Data Information and Application instructions.

WARRANTY

The Sherwin-Williams Company warrants our products to be free of manufacturing defects in accord with applicable Sherwin-Williams quality control procedures.

Liability for products proven defective, if any, is limited to replacement of the defective product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams.

NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

©2024 The Sherwin-Williams Company High Performance Flooring

HPF-1697217-12 10/24

United States & Canada sherwin-williams.com/resin-flooring swflooring@sherwin.com

THE SHERWIN-WILLIAMS DIFFERENCE

Sherwin-Williams High Performance Flooring delivers world-class industry subject matter expertise, unparalleled technical and specification service, and unmatched regional commercial team support to our customers around the globe.

RESUFLOR™ DECO FLAKE BC

APPLICATION INSTRUCTIONS

mailto:swflooring@sherwin.com

RESUPRIME™ 3579

STANDARD EPOXY PRIMER / BINDER

P A GP3579 S

P B GP3579B01 H

Protective

Marine Coatings

Revised: December 17, 2021

P D RESUPRIME 3579 is a high solids, clear or pigmented epoxy primer and binder resin. It is available in clear, red, white and gray, has good blush resistance, and is low in viscosity to promote penetration of the concrete substrate and excellent wetting of mortar aggregate.

A

• Good blush resistance at room temperature

• Low modulus of elasticity, stress relieving

• Acceptable for use in USDA inspected facilities

T U RESUPRIME 3579 is an epoxy primer for coatings, slurries, mortar overlays, and patches. It can be also used as a binder resin. For slurries, mortar and patching systems. Suitable for use in the Mining & Minerals industry.

L

• Slab on grade requires vapor/moisture barrier

• Surface must be clean and dry

• Cool damp conditions may cause surface blushing

• Substrate must be structurally sound and free of bond inhibiting contaminants

• During installation and initial cure cycle substrate and ambient air temperature must be at a minimum of 50ºF (10ºC).

Substrate temperature must be at least 5ºF (3ºC) above the dew point (for lower temperature installation contact your Sherwin-Williams representative.

• When required, adequate ventilation shall be provided and proper clothing and respirators worn

• Strictly adhere to published coverage rates

S P Proper inspection and preparation of the substrate to receive resinous material is critical. Read and follow the “Instructions for Concrete Surface Preparation” (Form G-1) for complete details.

continued on back

P C Color: Clear, Red, Gray, White

Mix Ratio: 2:1

Volume Solids: 96% ± 2%, mixed

Weight Solids: 96% ± 2%, mixed

VOC (EPA Method 24): <50 g/L mixed: 0.41 lbs/gal

Viscosity, mixed: 2,100 cps

Recommended Spreading Rate per coat:

Minimum Maximum

Wet mils (microns): 6 (150) 30 (750) ~Coverage sq ft/gal (m2/L): varies according to usage

Drying Schedule @ 6 mils (150 microns) wet:

@ 73°F (23ºC)

To touch: 6-8 hours To recoat: 10-20 hours

If maximum recoat time is exceeded, abrade surface before recoating.

Drying time is temperature, humidity, and fi lm thickness dependent.

Pot Life: gallon mass 25-30 minutess @ 73°F (23ºC)

Shelf Life:

Flash Point:

Part A: 36 months, unopened Part B: 36 months, unopened Store indoors at 50°F (10°C) to 90°F (32°C)

>230°F (>110°C), ASTM D 93, mixed

P C Test Name Test Method Results Adhesion ACI 503R 300 psi concrete failure Compressive Strength

ASTM D 695 9,000 psi

Flammability Self-extinguishing over concrete

Flexural Strength ASTM D 790 6,000 psi Hardness, Shore D ASTM D 2240 75/65 Tensile Strength ASTM D 638 3,000 psi

RESUPRIME™ 3579

STANDARD EPOXY PRIMER / BINDER

P A GP3579 S

P B GP3579B01 H

Protective

Marine Coatings

Revised: December 17, 2021

T Do not tint.

C Clean up mixing and application equipment immediately after use. Use toluene or xylene. Observe all fi re and health precau-tions when handling or storing solvents.

S Refer to the SDS sheet before use.

Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.

M Occasional inspection of the installed material and spot repair can prolong system life. For specifi c information, contact your Sherwin- Williams representative.

D The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company.

Such information and recommendations set forth herein are subject to change and pertain to the product off ered at the time of publication. Consult your Sherwin- Williams representative to obtain the most recent Product Data Information and Application Bulletin.

W The Sherwin-Williams Company warrants our products to be free of manufactur-ing defects in accord with applicable Sherwin-Williams quality control procedures.

Liability for products proven defective, if any, is limited to replacement of the defec-tive product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE

OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,

STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-

CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

P I A

APPLICATION INSTRUCTIONS:

1. Add 2 parts 3579A (resin) to 1 part 3579B (hardener) by volume.

Mix with low speed drill and Jiff y blade for three minutes and until uniform. To insure proper system cure and performance, strictly follow the mix ratio.

2. Resuprime 3579 may be applied via spray, roller or brush.

Apply evenly, with no puddles. Coverage will vary depending upon porosity of the substrate and surface texture.

3. Resuprime 3579 application varies upon usage.

NOTE: Epoxy materials may tend to blush at the surface especially in humid environments. After the surface is primed and before installation of each subsequent coat, surface must be examined for blush (a whitish greasy fi lm and/or low gloss). The blush must be completely removed prior to recoating using warm detergent water or through solvent wipe.

Epoxy materials will appear to be cured and dry to touch prior to full chemical cross linking. Allow epoxy to cure for 2-3 days prior to exposure to water or other chemicals for best performance.

O I

Packaging:

Part A: 1 gallon (3.8L) and 5 gallon (18.9L) containers Part B: 1 gallon (3.8L) and 5 gallon (18.9L) containers

Weight: 9.4 ± 0.2 lb/gal; 1.13 Kg/L mixed, may vary by color

RESUFLOR™ 3746

HIGH PERFORMANCE EPOXY

Pඉකග A GP3746 Sඍකඑඍඛ

Pඉකග A GP8746 ඟඑගඐ Aඖගඑඕඑඋකඊඑඉඔ Aඏඍඖග

Pඉකග B GP3746B01 Hඉකඌඍඖඍක

Pඉකග B GP3746B02 Fඉඛග Cඝකඍ Hඉකඌඍඖඍක

Revised: December 9, 2022 www.sherwin-williams.com/protective

P D RESUFLOR 3746 High Performance Epoxy is a two-component, recoatable epoxy and binder resin. It may be used directly over primed substrates, or as a gloss seal coat over decorative slurry and mortar systems. Resufl or 3746 is extremely hard wearing, chemical, impact and abrasion resistant.

A

• Impact and abrasion resistant

• Durable, easy to clean

• Chemical resistant

• Suitable for use in USDA inspected facilities

• Acceptable for use in Canadian Food Processing facilities, categories: D2 (confi rm acceptance of specifi c part numbers/ rexes with your Sherwin-Williams representative)

• Available with an antimicrobial agent (GP8746 series)

• Tint bases can be tinted using Maxitoner @ 50% tint strength -see Tinting section on next page for details

T U RESUFLOR 3746 High Performance Epoxy should be used in areas where maintenance of a high performance, aesthetically appealing and chemical resistant epoxy system is required.

Resufl or 3746 is suited for use in clean rooms, laboratories, workshops, and light assembly areas.

L

• Slab on grade requires vapor/moisture barrier

• Substrate must be structurally sound, dry and free of bond inhibiting contaminants

• During installation and initial cure cycle substrate and ambient air temperature must be at a minimum of 50°F (10°C). Substrate temperature must be at least 5°F (3ºC) above the dew point (for lower temperature installation contact your Sherwin- Williams representative).

• Maximum dry surface temperature not to exceed 160°F (71°C)

• Strictly adhere to published coverage rates

• Apply clear at only 10-15 mils (250-375 microns) maximum per coat

S P Proper inspection and preparation of the substrate to receive resinous material is critical. Read and follow the “Instructions for Concrete Surface Preparation” (Form G-1) for complete details.

P C Finish: Gloss

Color: Clear, Standard Colors Wide range of colors possible Tintable: W01 (white tint base) and T04 (ultra deep tint base) See page 2 for additional tint details.

Volume Solids: 99%, mixed

Weight Solids: 99%, mixed

Mix Ratio: 2:1

VOC (EPA Method 24): <100 g/L; 0.83 lbs/gal, mixed continued on back

P C (C ' )

Recommended Spreading Rate per coat:

Minimum Maximum

Wet mils (microns): 10.0 (250) 30.0 (750) ~Coverage sq ft/gal (m2/L): 53 (1.3) 159 (3.9)

Drying Schedule @ 10.0 mils (250 microns) wet:

@ 55ºF (13ºC) @ 72°F(22°C) @ 95°F(35°C)

Standard Hardener: 50% RH To touch: 16-24 hours 6-12 hours 4-8 hours To recoat:

minimum 24 hours 8 hours 6 hours maximum 48 hours 24 hours 24 hours

Foot traffi c: 48 hours 24 hours 18 hours Heavy traffi c: 96 hours 72 hours 60 hours Full cure: 7 days 7 days 7 days

Fast Cure Hardener:

To touch: 3-4 hours To recoat:

minimum 6 maximum 12

Foot traffi c: 10-12 hours Heavy traffi c: 24 hours Full cure: 7 days

If maximum recoat time is exceeded, abrade surface before recoating.

Drying time is temperature, humidity, and fi lm thickness dependent.

Pot Life (Standard) gallon mass

60 minutes 40 minutes 20 minutes

Pot Life (Fast Cure) gallon mass

25 minutes

Shelf Life: Part A: 18 months, unopened Part B (Standard): 12 months, unopened Part B (Fast Cure): 12 months, unopened Store indoors at 40°F (4.5°C) to 100°F (38°C)

P C Test Name Test Method Results Abrasion Resistance

ASTM D4060,

CS17 wheel, 1000 cycles

76 mg loss

Adhesion ACI 503R 300 psi, concrete failure Flammability Self-extinguishing over concrete Flexural Strength ASTM D 790 ~12,400 psi Hardness, Shore D ASTM D 2240 77 Impact Resistance MIL-D-3134J Direct: 160 in-lb

Reverse: 20 in-lb

*Surface Burning ASTME84/

NFPA 255

Flame Spread Index 20;

Smoke Development Index 90

Tensile Strength ASTM D 638 3527.4 psi *Resufl or Aqua 3477 at 1.5 mils (40 microns) DFT topcoated with Resufl or 3746 at 17.5 mils (438 microns) DFT

RESUFLOR™ 3746

HIGH PERFORMANCE EPOXY

Pඉකග A GP3746 Sඍකඑඍඛ

Pඉකග A GP8746 ඟඑගඐ Aඖගඑඕඑඋකඊඑඉඔ Aඏඍඖග

Pඉකග B GP3746B01 Hඉකඌඍඖඍක

Pඉකග B GP3746B02 Fඉඛග Cඝකඍ Hඉකඌඍඖඍක

Revised: December 9, 2022

C R For comprehensive chemical resistance information, consult the Chemical Resistant Guide and contact your Sherwin-Williams representative.

C Clean up mixing and application equipment immediately after use.

Use toluene or xylene. Observe all fi re and health precautions when handling or storing solvents.

S Refer to the SDS sheet before use.

Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.

M Occasional inspection of the installed material and spot repair can prolong system life. For specifi c information, contact your Sherwin- Williams representative.

D The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company.

Such information and recommendations set forth herein are subject to change and pertain to the product off ered at the time of publication. Consult your Sherwin- Williams representative to obtain the most recent Product Data Information and Application Bulletin.

W The Sherwin-Williams Company warrants our products to be free of manufactur-ing defects in accord with applicable Sherwin-Williams quality control procedures.

Liability for products proven defective, if any, is limited to replacement of the defec-tive product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE

OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,

STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-

CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Pකඌඝඋග Iඖඎකඕඉගඑඖ S / A

MATERIAL DELIVERY AND STORAGE:

Store materials in accordance instructions, with seals and labels intact and legible. Keep resins, hardeners, and solvents separated from each other and away from sources of ignition. 18 months shelf life is expected for products stored between 40°F (4.5°C) - 100°F (38°C).

APPLICATION INSTRUCTIONS:

1. Premix GP3746 (resin) using a low speed drill and Jiff y blade.

Mix for one minute and until uniform, exercising caution not to introduce air into the material.

2. Add 2 parts GP3746 (resin) to 1 part GP3746B (hardener) by volume. Mix with low speed drill and Jiff y blade for three minutes and until uniform. To insure proper system cure and performance, strictly follow mix ratio recommendations.

3. Apply GP3746 using a squeegee or trowel and back roll with a 3/8" nap roller at a spread rate of 50-160 square feet per gallon (1.3-4.0 meters squared per liter) to yield 10-30 mils (250-750 microns) WFT making sure of uniform coverage. Take care not to puddle materials and insure even coverage.

4. Allow to cure 24 hours minimum before opening to traffi c and 72 hours before water exposure.

Note: Epoxy materials will appear to be cured and “dry to touch” prior to full chemical cross linking. Allow epoxy to cure a minimum of 3 days prior to exposure to water or other chemicals for best performance.

T Can be tinted with GIS and HPF Universal colorants. For Universal colorants use one pint per 3-gallon mix of GP3746A01 (Clear) for most colors, and two pints per 3-gallon mix for White, Bright Yellow, Light Gray, and Rotunda Red.

Ensure that the colorant is thoroughly incorporated prior to use.

Do not tint package colors.

RESUTILE™ HPS 100/SDS/HTS 100

RESUTILE HPS 100: pages 1-3

RESUTILE SDS: pages 4-6 RESUTILE HTS 100: pages 7-9

Pඉකග A GP4640A01 Cඔඍඉක

Pඉකග B GP4640B01 Hඉකඌඍඖඍක

Revised: June 26, 2024

P D RESUTILE HPS 100 Gloss Urethane Topcoat is a clear, high solids, two-component, aliphatic, moisture-cure urethane applied over an epoxy primer or used to recoat an existing epoxy or urethane fl oor.

Advantages:

• LEED® v4 – Indoor Air Quality credits available - meets requirements per CDPH-CA Section 01350 Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental chambers Version 1.2.

• Designed to withstand industrial traffi c

• Light stable, high-gloss fi nish provides superior light refl ectivity

• Resists Skydrol®, jet fuels and other industrial chemicals

• Low VOC (7 g/L). (Complies with SCAQMD VOC regulations.)

T U

• Hangar fl oor

• Automotive manufacturing

• Mechanical room

• Assembly / Production

• Packaging

• Clean room / lab

G I Use colorants at a rate of one unit per 1-gallon (3.78 litres) of Resutile HPS 100. Standard colorants: White, Yellow and Sandy Beige will not impart total hide. Similar colorants also may not hide as well.

LIMITATIONS:

Contamination (Fisheyes): Product may fi sheye if oil, silicones, mold release agents or other contaminants are present.

Chemical Resistance / Staining: Reduced chemical resistance and staining is possible in pigmented versions of the system.

O I ~1 gallon (3.8L) mix:

Part A: 0.74 gallons (2.8L) in a gallon (3.8L) can Part B: 0.20 gallons (0.8L) in a quart (0.9L) can

~2 gallon (7.6L) mix:

Part A: 1.48 gallons (5.6L) in a 5 gallon (18.9L) pail Part B: 0.40 gallons (1.5L) in a 0.5 gallon (1.9L) can continued on back

P C Color: Clear

Mix Ratio: 1:1 by unit

Volume Solids: 91.60%, mixed (ASTM D2369)

Weight Solids: 91.34%, mixed (ASTM D2369)

VOC (ASTM D3960): 7 g/L ; 0.06 lb/gal

Recommended Spreading Rate per coat:

Minimum Maximum

Wet mils (microns) 3.2 (80) 3.2 (80) Dry mils (microns) 2.9 (73) 2.9 (73)

~Coverage sq ft/gal (m2/L): 500 (12.3) 500 (12.3)

Drying Schedule:

60°F/16°C

60°F/16°C

75°F/24°C

90°F/32°C

90°F/32°C

20% RH 80% RH 13% RH 20% RH 80% RH

Tack Free: 12-16 hours12-16 hours 6.5 hours 3.5 hours 1.5 hours Foot Traffi c: 24 hours 24 hours 24 hours 24 hours 24 hours Recoat Window: Maximum: Up to 24 hours for all conditions

Shelf Life: 12 months, unopened Store indoors at 65°F (18°C) to 90°F (32°C)

P C Test Name Test Method Results* Abrasion Resistance ASTM D4060, CS-17 wheel, 1000gm load, 1000 cycles

14.9 mg loss

Coeffi cient of Friction ASTM D2047 0.61 Elongation ASTM D2370 6% Flammability ASTM D635 182 mm/min Koenig Hardness, 3 Mil Film (resin only)

ASTM D4366 171.3

Tensile Strength ASTM D2370 6,250 psi Water Absorption, 24-hour immersion

ASTM D570 1.81%

Wet Static Coeffi cient of Friction, BOT 3000

ANSI/NFSI

B101.1

0.99

*results are based on conditions at 77°F (25°C)

A I Recoat: Resutile HPS 100 may be used to coat over an existing epoxy or urethane in sound condition. Detergent scrub and rinse with clean water to remove surface dirt, grease, oil and contami-nants. Floor must be sanded thoroughly with 100 grit paper prior to recoating. The use of more aggressive paper will introduce deep grooves that will not be covered by a single, thin coat of urethane;

swirl marks will be particularly evident if the topcoat is glossy.

We recommend thorough sanding with a swing-type buff er so that multiple scratch marks cause an obvious gloss loss on all areas (depressions will remain shiny), and the fl oor is uniformly dulled.

The ability to see individual scratch marks is an indication that sanding is not adequate. Scrub with detergent and rinse with clean water before coating.

Resutile HPS 100 must be applied over a Sherwin-Williams' 100% solids epoxy primer. Epoxy must be thoroughly sanded and cleaned prior to application of Resutile HPS 100.

Premix Part A for 3 minutes using a Jiff y mixer blade with slow speed drill. Pot Life: Mix only enough material which can be used in a two-hour period. Note: Once opened, this material cannot be resealed for later use.

Colors: Premix Sherwin-Williams colorants before adding to Resutile HPS 100 to ensure uniform color. Add colorant to Resutile HPS 100 Part A.

Add Part B while mixing. Mix for 3 minutes using a Jiff y mixer blade and slow speed drill. Pour into application tray.

Apply Resutile HPS 100 at the rate of 500 sq. ft./gallon (46.45 m2/3.78 litres) with a 3/8" nap roller. For proper appearance and development of physical properties, it is crucial that material is not applied above or below this rate. Dip the roller in the coating and lightly roll out excess in the application tray. Apply two 8-10 foot (2.4-3.0 meters) long paths on the concrete, making one stroke left to right and one right to left. Rewet the roller and apply two more paths adjacent to the fi rst pair. Rewet roller and apply a third pair adjacent to the second.

Spread the material evenly with V-shaped cross passes.

Make sure the fl oor has just enough coating to cover evenly.

Excess material could cause the fl oor to blister, especially in high humidity. Insuffi cient material will cause the fl oor to look non-uniform.

Level the area with straight passes that cross the initial material paths. These fi nal strokes will reduce roller marks. If the appearance is not satisfactory, reroll the area.

Allow coating to dry 24 hours at 75°F (24°C), 50% relative humidity before opening to light traffi c. Allow more time at low temperatures, low humidity or for heavier traffi c. Full coating properties take 14 days to develop.

Pකඌඝඋග Iඖඎකඕඉගඑඖ S P

CHECK THE TEMPERATURE AND HUMIDITY: Floor temperature and materials should be between 65°F (18°C) and 90°F (32°C). Humidity must be less than 80%. DO NOT coat unless fl oor temperature is more than fi ve degrees over the current, local dew point.

CHECK FOR MOISTURE: Concrete must be dry before application of this fl oor coating material. Concrete moisture testing must occur. In-situ relative humidity testing is recommended. Readings must be below 75% relative internal concrete humidity. Test methods can be purchased at www.

astm.org, see F2170, or follow manufacturer's instructions. If moisture issues are present, the use of a moisture mitigation system may be a consideration. Consult your Sherwin-Williams representative for further information / instructions.

NOTE: Although moisture testing is critical, it is not a guarantee against future problems. This is especially true if there is no vapor barrier or the vapor barrier is not functioning properly and/or you suspect you may have concrete contamination.

Additional testing may be necessary to determine the vapor barrier and any contamination.

A E

• Protective clothing • Roller assembly (18")

• Jiff y® mixer blade • Medium (3/8") nap roller

• Application tray • 100 grit sandpaper

• Disc machine • Slow speed drill (500 rpm or less)

ASSEMBLE EQUIPMENT: Due to the limited pot life of the material, all application equipment, etc. should be ready for immediate use. (Clean roller with tape to remove any residual lint.)

M Allow fl oor coating to cure at least one week before cleaning by mechanical means (e.g., sweeper, scrubber, disc machine).

Care: Proper maintenance will increase the life and help maintain the appearance of your new Sherwin-Williams fl oor coating.

Sweep and scrub your new coating regularly, as dirt and dust are abrasive and can quickly dull the fi nish, decreasing the life of your coating. Remove spills quickly as certain chemicals may stain and could possibly permanently damage the fi nish. Use soft nylon brushes or white pads on your new fl oor coating.

Any brush more abrasive than a soft nylon or white pad can cause premature loss of gloss.

Caution: Avoid scratching or gouging the surface. All fl oor coatings will scratch if heavy objects are dragged across the surface. Do not drop heavy or pointed items on the fl oor as this may causing chipping or concrete popouts in the case of a weak cap. Rubber tires can permanently stain the fl oor coating from plasticizer migration. Plexiglass® between the tire and the fl oor coating can prevent discoloration. Rubber burns from quick stops and starts can heat the coating to its softening temperature, causing permanent marking.

Repair: Repair gouges or scratches or chip outs as soon as possible to prevent moisture or chemical contamination.

T Only tint with HPF Universal Colorants. Do not tint with GIS colorants. Use two pints of colorant per ~1.88 gallon mix of Parts A and B.

Standard colorants: White, Bright Yellow, Rotunda Red and Sandy Beige will not impart total hide. Similar colorants also may not hide as well.

S Refer to the SDS sheet before use.

Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.

D The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company.

Such information and recommendations set forth herein are subject to change and pertain to the product off ered at the time of publication. Consult your Sherwin- Williams representative to obtain the most recent Product Data Information and Application Bulletin.

W The Sherwin-Williams Company warrants our products to be free of manufactur-ing defects in accord with applicable Sherwin-Williams quality control procedures.

Liability for products proven defective, if any, is limited to replacement of the defec-tive product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE

OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,

STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-

CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Pකඌඝඋග Iඖඎකඕඉගඑඖ C R

Reagent 1 Day 7 Days Hydrochloric Acid 10% E E Hydrochloric Acid 30% (Muriatic) E E Nitric Acid 10% G P Phosphoric Acid 50% G G Sulfuric Acid 37% (Battery Acid)

E G

Acetic Acid 10% E E Citric Acid 10% E E Oleic Acid E E Ammonia Hydroxide 10% E E Sodium Hydroxide 50% E E Ethylene Glycol (Antifreeze)

E E

Isopropyl Alcohol G G Methanol G F D-Limonene E E JP-4 Jet Fuel E E Gasoline E E Mineral Spirits E E Xylene E E Methylene Chloride P P

MEK F F

PMA E G

Ammonium Nitrate 20% E E

Brake Fluid E E

Bleach E E

Motor Oil (SAE 30) E E

Skydrol® 500B E E

Skydrol® LD4 E E

Sodium Chloride 20% E E

1% Tide® Laundry Soap E E

10% Trisodium Phosphate E E

Coff ee E E

Coke® E E

Ketchup E E

Mustard G* G*

Red Wine E G*

3MTM DuraPrepTM G* F

Purdue Betadine Solution G* G*

ASTM D1308 Test Method 3.1.1 spot test, covered. Results are based on 1-day and 7-day. Coating cured 2 weeks prior to testing.

E - Excellent (no adverse eff ect) - Recommended G - Good (limited adverse eff ect) - Use for short-term exposure only F - Fair (moderate adverse eff ect) - Not recommended P - Poor (unsatisfactory) - Little or no resistance to chemical

*only adverse eff ect was staining

NOTE: Reduced chemical resistance and staining is possible in pigmented versions of the system

RESUTILE™ SDS

STATIC CONTROL DISSIPATIVE URETHANE

Pඉකග C GP4621C01 Aඏඏකඍඏඉගඍ

Revised: May 14, 2024

P D RESUTILE SDS is a light-stable urethane that contains a conductive fi ller to yield static dissipative properties. This coating has a satin appearance for long-lasting durability.

Advantages:

• Electrostatic discharge control - meets ANSI/ESD S20.20- 2007 for resistance <1x109 ohms and <100 volts Body Voltage Generation

• LEED® v4 – Indoor Air Quality credits available - meets requirements per…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .