OFPM Outage Schedule
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_Answers_2.docx | DOCX document | |
| RFI_Answers.docx | DOCX document | |
| Guidelines_for_Contractors_and_A-E_firms.pdf | ||
| Wage_Determination.docx | DOCX document | |
| Statement_of_Work.docx | DOCX document | |
| Equipment_List.xlsx | XLSX spreadsheet | |
| SB1341-18-RQ-0263_Attachment_II_-_Applicable_Provisions_and_Clauses.docx | DOCX document | |
| SB1341-18-RQ-0263_-_Attachment_III_-_Evaluation_Criteria.docx | DOCX document | |
| SB1341-18-RQ-0263_-_Attachment_I_-_Combined_Synopsis_Solicitation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT VII
The proposed Annual VDF Maintenance must be coordinated with the campus HVAC outage schedule. The outage schedule cycle for each Building is three times annually. VFDs located in Building 302, Steam and Chilled Water Generation Plant and Building Pump VFDs will be scheduled for Maintenance on the Site Wide Outages. These are semiannual campus wide outages (Friday evening thru Sunday afternoon) usually during the month of April and October.
Below is an example HVAC maintenance cycle for the NIST, Gaithersburg Campus:
image3.emf bldg301_10242017.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 301
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR OCTOBER, 2017
DATE UNIT ROOMS AFFECTED
MON
5/31
TUES ARU-1 West Side of the Main Warehouse Addition
10/24 ARU-2 East Side of the Main Warehouse Addition
E-4A VOLATILE LIQUID AND GAS STORAGE
E-4B VOLATILE LIQUID AND GAS STORAGE
ACU-C1 MEP Office Area
ACU-C2 MEP Office Area
ACU-C3 MEP Office Area
ACU-C4 MEP Office Area
ACU-C5 MEP Office Area
WED ACU-1 ALL OFFICES 'A' AND 'B' WINGS
10/25 ACU-2 SHOPS
ACU-11 Office Areas B145-1,2,3,4,5,6,7 B147-1,2,3,4,5
AW-1 PAINT SHOP
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
image4.emf bldg318_1032017.xlsx
JUNE
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
DATE 220 245 301 318 320
TUES ACU-1,2, 5, 5A 6,
6/21 ACU-7, 7A, 8, 11,
21, RU-4
WED ACU-3, 4, 4A, 10,
6/22 10A, 10B, 12, 18, 18A, 19, RU-1, 2
ACU-15, 16, 17, 20
THUR A-100 FANS, ACU-1, 1A, 1B,
6/23 ACU-2, 2A, 10, 17,
SAT AHU-1, 2, MAU-1, SH-1, 2
6/18 RF-1, 2, LP-1
MON ACU-3, 5, 6, 11A, 16,
6/27 Cobolt-60, ACU-19, E-96-99
TUES ARU-1, 2, E-4A/B, ACU-C1-C5
6/28
WED ACU-1, 2, 11, AW-1
6/29
THUR ACU-1, 2, 3, ERU-1, 2
6/30
* CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
* THESE BUILDINGS ARE DUE FOR PM THIS MONTH WITHOUT A SCHEDULED OUTAGE, 103, 303, 309, 315.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 220
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR JUNE 2016*
DATE UNIT ROOMS AFFECTED
TUES ACU-1 EVEN (A56-A68) (A154-A168) (A254-A268) (A354-A368) and E-FANS
6/21 ACU-2 ODD (B53-B67) (B155-B167) (B253-B267) (B355-B367) and E-FANS
ACU-5 ODD (A45-A67) (A145-A167) (A245-A267) (A345-A367)
ACU-5A ODD SUPPLEMENTAL TO ACU-5 ROOM A-67
ACU-6 EVEN (B40-B64) (B140-B170) (B240-B270) (B340-B370)
ACU-7 ODD (A25-A37) (A103-A131) (A203-A235) (A303-A335)
ACU-7A ODD (A23-A37)
ACU-8 EVEN (B26-B28) (B104-B128) (B204-B228) (B304-B328)
ACU-11 EVEN (A110-A118) (A206-A218) (A306-A320) and E-FANS
ACU-21 ROOMS B66 AND B68 Add ACU-9
RU-4 REFRIGERATION UNIT FOR ACU-7A ROOMS (A25-A37)
WED ACU-3 EVEN (A38-A54) (A138-A152) (A238-A256) (A338-A354)
6/22 ACU-4 ODD (B39-B51) (B139-B153) (B239-B251) (B339-B353)
ACU-4A SUPPLEMENTAL TO ACU-4 ROOM B239
ACU-10 ODD (B25-B33) (B121-B133) (B219-B233) (B321-B333)
ACU-10A SUPPLEMENTAL TO ACU-10 ROOM B231
ACU-10B SUPPLEMENTAL TO ACU-10 ROOM B233
ACU-12 ODD (B109 - B119)(B205 - B217)(B305 - B319) and E-FANS
ACU-18 ROOMS (B05-B23) B08, B22, B24, B105, B107,
ACU-18A EVEN (B10-B20)
ACU-19 EVEN (A06-A24) (A03-A21) A106, A108
RU-1 SHEFFIELD
RU-2 BRINE SYSTEM, ACU-18, ACU-19
ACU-15 ROOM C-05
ACU-16 ROOMS C-03 AND C-04
ACU-17 ROOM C-06
ACU-20 ROOM C-02
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
3. ROOM NUMBERS REFLECTED AS EVEN (B104-B136) FOR EXAMPLE INCLUDE
ONLY EVEN NUMBERS BETWEEN 104 AND 136. LIKEWISE, THIS RULE APPLIES
TO THE ODD NUMBERED ROOMS AS WELL.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 245
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR JUNE 2016*
DATE UNIT ROOMS AFFECTED
THUR A-100 Fans EXHAUST FOR ROOM A-100
6/23 ACU-1 ROOMS (A019) (A005) (A017) (A007) MEAS. ROOM 1, 2 & 3
ACU-1A ROOMS (A010 LINAC ROOM)
ACU-1B ROOMS (A019) (A004) (A016) (A09) (A10) (A012) (OUT OF SERVICE)
ACU-2 ROOMS (A01) (A02) (A04) (A06) (A09) (A10) (A012)
ACU-2A ROOMS (A09) LINAC POWER
ACU-10 ROOMS C135 & C137
ACU-17 (C101-C115), C121, C125, C131, C133, (C201--C205), C209, C215, C217
(C225-C229), C233, C235, C301, C313, C317, C321, (C327-C337)
MON ACU-3 ROOM D-06, (MOTOR GENERATOR ROOM)
6/27 ACU-5 ROOM C-07, SYNCHOTRON (MACHINE ONLY)
ACU-6 ROOMS D03, D04, D05
ACU-11A ROOM C-11
ACU-16 (B100-B119), C106, C108, C110, C112, C114, C116, C118, C136, C138
(C206-C216), C234, C238 (C306-C318), C334, C336, C338
Cobolt-60 ROOM B101
ACU-19 F-WING, ROOM B101
E-96 ROOM E105
E-97 ROOM E106
E-99 ROOM E-103
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
3. ROOM NUMBERS REFLECTED AS EVEN (B104-B136) FOR EXAMPLE INCLUDE
ONLY EVEN NUMBERS BETWEEN 104 AND 136. LIKEWISE, THIS RULE APPLIES
TO THE ODD NUMBERED ROOMS AS WELL.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 301
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR JUNE 2016*
DATE UNIT ROOMS AFFECTED
MON
5/31
TUES ARU-1 West Side of the Main Warehouse Addition
6/28 ARU-2 East Side of the Main Warehouse Addition
E-4A VOLATILE LIQUID AND GAS STORAGE
E-4B VOLATILE LIQUID AND GAS STORAGE
ACU-C1 MEP Office Area
ACU-C2 MEP Office Area
ACU-C3 MEP Office Area
ACU-C4 MEP Office Area
ACU-C5 MEP Office Area
WED ACU-1 ALL OFFICES 'A' AND 'B' WINGS
6/29 ACU-2 SHOPS
ACU-11 Office Areas B145-1,2,3,4,5,6,7 B147-1,2,3,4,5
AW-1 PAINT SHOP
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 318
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR OCTOBER, 2017
DATE UNIT ROOMS AFFECTED
TUES ACU-1 Fire Dept Area
10/3 ACU-2 Police Dept Area
ACU-3 Conference Room L100
ERU-1 B107 (Men’s Locker Room), B109 (Gym), B111 (Women’s Locker Room)
ERU-2 D102
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 320
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) JANUARY 2017
DATE UNIT ROOMS AFFECTED
WED AHU-1 Rooms 01 thru 14, and rooms 33 thru 42
3:30PM-4:30PM 1/4 RF-1
THURS AHU-2 Rooms 15 thru 23, and rooms 24 thru 32
3:30PM-4:30PM 1/5 RF-2
MON MAU-1 Kitchen Exhaust Fans
2:30PM-4:30PM 1/9 SH-1, 2
LP-1
image5.emf
Building 235 HVAC Maintenance Sept_11_12_13_14_18_2017.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 235
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR SEPTEMBER 11, 12, 13, 14, 18, 2017
DATE UNIT ROOMS AFFECTED
MON AHU-1 K WING K WING OFFICES
9/11 AHU-2 K-WING OFFICE AREAS
AHU-3 K WING OFFICES
AHU-4 NEW GUIDE HALL SECTION
ACU-13 BASEMENT AND EQUIPMENT RMS. IN CNRF AREA
HV-13, EF-7 PUMP ROOM SUPPLY & EXHAUST FANS.
EF-33 THRU EF-37 K WING EXHUST FANS
TUES ACU-4 SUPPLY COLD LAB AREA
9/12 ACU-5 FRESH AIR SUPPLY FOR COLD LAB UNITS
ACU-6 SUPPLY FOR ROOMS B126, B127, B131, A134
ACU-7 COLD LAB (A107-A127) (A136-A158)
ACU-8 CONFERENCE AND LOBBY SYSTEM, A105, A132, B129, B130
ACU-9 FRESH AIR SUPPLY TO WARM LAB UNITS
ACU-10 SUPPLY TO B-WING OFFICES
EF-8, EF-9 EXHAUST RM A09, EXHAUST RM A02 AND A04
HV-15 A06
HV-16, EF-11 SUPPLY TO SWITCH GEAR & BATTERY ROOM A02, A04
HV-14 SUPPLY TO HOT CELL AREA
HV-14 SUPPLY TO HOT CELL AREA
HV-17 SUPPLY TO WARM LABS (B140-B154)
HV-18 SUPPLY TO WARM LABS (B119-B125) (B120-B138) & B146
AHU-1 B WING B-161 THRU B-190, NEW B WING OFFICES
WED EF-1 REACTOR EQUIPMENT
9/13 EF-23 REACTOR EQUIPMENT
VU-3 REACTOR EQUIPMENT
VU-4 REACTOR EQUIPMENT
VU-27 REACTOR EQUIPMENT
HV-11 REACTOR EQUIPMENT
ACU-3 REACTOR EQUIPMENT
ACU-1 REACTOR EQUIPMENT
ACU-2 REACTOR EQUIPMENT
EF-2 REACTOR EQUIPMENT
THURS E-8, E WING
9/14 ACU-15 CNRF OFFICE AREAS
ACU-16 GUIDE HALL AREA
ACU-17
ACU-18
ACU-19
ERV-1A,B,C
MON EF-19A THRU 19H ROOMS A109, A146, A115, A121, A152, A127, A158, A138 EXHAUST
9/18 EXHAUST FANS EH-131, 132, 133, 134, 135, 136, AND EH-138
ACU-14 CNRF PREPERATION LAB, ELECTRIC LAB, ZONES 5, 7, 9, CHEM LAB, COMPUTER EQUIPMENT LAB
EF-20 HOOD EXHAUST ROOM B126
EF-21 EXHAUST FROM ROOM A105, B100
EF-25 PART OF EMERGENCY EXHAUST & RECIRC. SYSTEM ROOM C-100, C-200.
HV-12 SUPPLY ROOM C001, C002, C003, C004
VU-5, 6, 19 EMERGENCY EXHAUST & RECIRC. SYSTEM ROOM C-100, C-200.
FCU-1 ROOM C03
EF-12, EF-13, EF-14 EXHAUST ROOM B128, B136, B138, EXHAUST HOT CELL #2, EXHAUST HOT CELL #1
EF-15, EF-17, EF-24 HOOD EXHAUST (B119-B154), EXHAUST ROOM B-141, CLEAN ROOM B-125
VU-25, VU-26 SERVICE AREA EXHAUST RM. B146
ALL REACTOR EQUIPMENT MAINTENANCE MUST FIRST BE CORRDINATED WITH OPERATIONS
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
3. REACTOR HEALTH PHYSICS OFFICE MUST BE NOTIFIED OF ANY MAINTENANCE WORK DONE
ON VENTILATION SYSTEMS IN THE "C" WING AND B200 LEVEL PRIOR TO ANY WORK PERFORMED.
image6.emf
Sept_5th_2017_bldg.205.xlsx Sheet1
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 205
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR September 5, 2017
DATE UNIT ROOMS AFFECTED
DATE
ERROR:#REF!
ERROR:#REF!
ERROR:#REF!
ERROR:#REF!
ERROR:#REF!
TUE ACU-1 BURN CORRIDOR DRAFT
9/5 ACU-2 TEST FACILITY PRE CONDITIONING
ACU-3 SHOP CONDITIONING
ACU-4 OFFICE AREA CONDITIONING
ACU-5 ROOM 122, 123, 124 CONDITIONING
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image7.emf
Sept_6th_2017_bldg.320.xlsx Sheet1
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 320
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) September 6, 2017
DATE UNIT ROOMS AFFECTED
WED AHU-1 Rooms 01 thru 14, and rooms 33 thru 42
RF-1
AHU-2 Rooms 15 thru 23, and rooms 24 thru 32
RF-2
MAU-1 Kitchen Exhaust Fans
SH-1, 2
LP-1
image8.emf
Sept_19_20_21_2017_bldg218.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 218
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR September 19, 20, 21, 2017
DATE UNIT ROOMS AFFECTED
TUE AHU-502 F0009
9/19 AHU-503 F0005
AHU-504 F0001
AHU-505 E0024
AHU-506 E0006
AHU-515 C0005
AHU-516 C0007
AHU-517 C0009
AHU-507 E0004
AHU-508 E0013
AHU-509 E009
AHU-510 E0005
WED AHU-511 D0012
9/20 AHU-512 D0010
AHU-513 D0011
AHU-514 D0007, D0006
AHU-519 C0019
AHU-521 H002, H004, H016, H028
AHU-522
AHU-523 B0031, B0033, B0035, B0037, B0039, E0004-1, E0014, E0016, E0020, E0022, F0001-1, F0013, F0023, F0025
AHU-525 B0001-B0011, C0001-1, C0001, C0002, C0006, C0010, C0011, C0016, C0020, C0022
AHU-526 D0004, D0006
THURS AHU-518 C0009-1
9/21 AHU-520 C001, B001, B005, B007, B009, B025, A006, A005, A004, A001, A002
AHU-524 B0015, B0019, B0021, B0023, B0027, D0003, D0005, D0004
D0013, D0015, D0018, D0017, D0024, D0025, E0025, E0019, E0017, E0001
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image9.emf
Sept_25_2017_bldg217.xlsx
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Facilities Desk on x6928.
BUILDING 217
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR September 25, 2017
DATE UNIT ROOMS AFFECTED
MON
5/31
MON AHU-201 C102, C103, C104, C112, C115, C116, C118, C121
9/25 D104, D108, D114, D120, D122
AHU-203 D101, D105, D113, D117, D119, E101, E102, E106, E107
E108,E111, E112-E116,E117,E121-E122
AHU-204 F101-F122, G102-G122
AHU-202 A103-A155, B101-B163, H103-H121, A203-A255, B201-B263
AHU-205 C201
AHU-210 C101
AHU-211 D115
AHU-206&7 C111
EF-206A/B
AHU-208&9 C105-C109, Make up Air, G102, G104
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image10.emf
Sept_26_27_28_2017_bldg219.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 219
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR September 26, 27, 28, 2017
DATE UNIT ROOMS AFFECTED
TUES AHU-301 B0002
9/26 AHU-302 B0004
AHU-303 B0003
AHU-304 G0005
AHU-305 G0007
AHU-316 G0024
AHU-324 F0034
AHU-325 F0033
AHU-328 F0035
AHU-330
AHU-332 G0038
AHU-333
WED HRU-301 FUME HOOD EXHAUST
9/27 AHU-306 G0009
AHU-310 G0015
AHU-311 A0021-1
AHU-312 A0022
AHU-313 G0021
AHU-314 G0022
AHU-315 G0023
AHU-317 G0027
AHU-318 G0026
AHU-319 A0030
AHU-331 Entire Basement Floor
AHU-334
THURS AHU-307 B0008
9/28 AHU-308 G0011
AHU-309 B0012
AHU-320 F0032
AHU-321 F0031
AHU-322 G0032
AHU-323 G0032-1
AHU-326 G0034
AHU-327 F0036
AHU-329
AHU-335 B0014
AHU-336 B0010
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image11.emf
Nov_1_2_2017__bldg222.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 222
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR NOVEMBER 1st, 2nd, 2017
DATE UNIT ROOMS AFFECTED
WED ACU-1 ODD (B157-B167) (B239-B267) (B339-B367)
11/1 ACU-2 EVEN (A160-A168) (A240-A268) (A340-A368)
ACU-4 EVEN (A140-A158), ODD (B139-B155)
ACU-5 EVEN (B104-B168) (B204-B268) (B304-B368)
EF-1, 2, 3 West End Interior First Floor Exhaust
THURS ACU-6 EVEN (A106-A134) (A206-A234) (A306-A334)
11/2 ACU-9 ODD (B105-B133) (B205-B233) (B305-B333)
ACU-10 ODD (A103-A167) (A203-A267) (A303-A367)
WED
1/1
THUR
1/2
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. ROOM NUMBERS REFLECTED AS EVEN (B104-B168). FOR EXAMPLE INCLUDE
ONLY EVEN NUMBERS BETWEEN 104 AND 168. SIMILARY THOSE BETWEEN ODD
NUMBERS SUCH AS ODD (B105-B133) REFER ONLY TO THE ODD NUMBERS
BETWEEN 105 AND 133.
image12.emf
Nov_18_20_2017_bldg215.xlsx
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 215
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR NOVEMBER 18TH AND 20TH, 2017
DATE UNIT ROOMS AFFECTED
MON AHU-101 C/D B101, B101-1
11/20 AHU-101 E/F A102, A102-1
AHU-101 G/H B102, B102-1
AHU-101 I/J/K/L A103, A103-1, B103, B103-1
AHU-101 M/N A104, 104-1, A105-1
AHU-101 Q/R/S/T/O/P B105, B105-1, A106, B104, B104-1
AHU-102 A/B/C/D Clean Room Aisle
AHU-108 A/B Clean Room Aisle
AHU-109 A107
AHU-115 D105
AHU-116 E104
AHU-110 A/B B106, B106-1, B106-2, B107
AHU-111 A/B/C/D CO-B1-1 (AHU-111A/B), CO-C1-1 (AHU-111C/D)
ERROR:#REF! Clean Room Aisle
ERROR:#REF! Clean Room Aisle
ERROR:#REF! Clean Room Aisle
AHU-112 D101, D102, D102-3, D103, CO-D-1
8/12
SAT AHU-103, 104 MAKE UP AIR HANDLERS
11/18 EF-101 A/B, EF-102 A/B, EF-105 A/B ACID, SOLIVENT, AND HYDRIDE FUME EXHAUST SYSTEMS
8/12
AHU-106, EF-103, 104, 109, 112, 121, AND EF-122 NANO SUBFAB AREA/ BASEMENT AREA OF 215
AHU-101 A/B A101, A101-1, A101-2
AHU-113 D106, D107, D108, CO-D-1
AHU-114 A105, A105-2
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image13.emf
DEC04_2017_bldg217.xlsx
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Facilities Desk on x6928.
BUILDING 217
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR DECEMBER 04, 2017
DATE UNIT ROOMS AFFECTED
MON
5/31
MON AHU-201 C102, C103, C104, C112, C115, C116, C118, C121
12/4 D104, D108, D114, D120, D122
AHU-203 D101, D105, D113, D117, D119, E101, E102, E106, E107
E108,E111, E112-E116,E117,E121-E122
AHU-204 F101-F122, G102-G122
AHU-202 A103-A155, B101-B163, H103-H121, A203-A255, B201-B263
AHU-205 C201
AHU-210 C101
AHU-211 D115
AHU-206&7 C111
EF-206A/B
AHU-208&9 C105-C109, Make up Air, G102, G104
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
MON
ERROR:#REF!
TUES
ERROR:#REF!
WED
ERROR:#REF!
THUR
ERROR:#REF!
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image14.emf
DEC28_2017_bldg203.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Plant Division Service Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 203
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR DECEMBER 28, 2017
DATE UNIT ROOMS AFFECTED
THURS ACU-1 202,203
12/28 AHU-1 109,110,111,114,115,116,201,202,203,
AHU-2 101,102-104
AHU-3 102,103,105
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALLCHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image15.emf
Nov_6_7_2017_bldg304.xlsx Sheet1
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 304
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR NOVEMBER 6TH, 7TH, 2017
DATE UNIT ROOMS AFFECTED
MON ACU-5 MEASUREMENT SHOP ROOM 17
11/6 ACU-6 BALANCE INSPECTION SHOP ROOM 15
ACU-11 ROOM 162 SERVES TOOL CRIB
ACU-12 LOCATED IN ROOM 148 SERVES ROOM 149
ACU-1 OFFICE ON SOUTH SIDE OF BLDG. ROOMS 101, 124, 125, 126, 128
BASEMENT ROOMS. 04, 05, 06, 08, 09, 11, 12, 13 & 14.
ACU-3 MAIN MACHINE SHOP AREA ROOM 155
ACU-4 OPTICAL SHOP ROOMS 112, 113, 114, 117, 118, 120, 121, 122
ACU-7 SHEET METAL & WELDING ROOMS 158 & 159
TUES ACU-8 HYDROGEN ROOM 127
11/7 ACU-10 ROOMS 150-151 & 152
E-30 ROOMS 150-151 & 152
FCU-2, 3, 4 ROOM 125
FCU-5 ROOM 143
E-18 EXHAUST FAN ROOM 157
E-19 EXHAUST FAN ROOM 159
E-20 EXHAUST FAN ROOM 123
EH-112 ROOM 112
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULE OUTAGE
ACU-C4 C115, C117, C118, C119, C120
image16.emf
April_10_bldg233.xlsx
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
BUILDING 233
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR APRIL 10, 2017
DATE UNIT ROOMS AFFECTED
MON ACU-1 SUPPLY AIR TO ALL OFFICES AND LABS
4/10 ACU-2 SUPPLY AIR TO ROOM A127 & A119
VU-1 VENTILATION UNIT ROOM A137
ESF-1, 2 ELECTROSTATIC FILTERS, ROOMS A152 & A154
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.
image1.emf bldg216_10122017.xlsx
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 216
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR OCTOBER 2017
DATE UNIT ROOMS AFFECTED
THURS AHU-401 F101 - F122, G101 - G115
10/12 AHU-402 A101 - A157, B103 - B157, A201 - A257, B203 - B257
AHU-404 C102 - C122, D101 - D117 Odd
AHU-403 D102 - D122 Even, E101 - E122
AHU-405 C201
1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM FUME HOODS PRIOR TO SCHEDULED OUTAGE
ACU-C4 C115, C117, C118, C119, C120
image2.emf bldg227_10162017.xlsx Sheet1
Safety Cautionary Note:
HVAC preventative maintenance work may require use of solvents or cleaners that can produce odors.
If you detect an odor, please contact the Trouble Desk on x6928.
WARNING - ROOM HOOD EXHAUST WILL BE SECURED AT THE SAME TIME AIR CONDITIONING
IS SECURED FOR MAINTENANCE WITH THE AIR CONDITIONING UNITS.
BUILDING 227
SCHEDULE FOR AIR CONDITIONING UNITS (ACU) OUTAGES FOR OCTOBER 2017
DATE UNIT ROOMS AFFECTED
MON AHU-6-1, 6-2, OFFICE SPACE ALL FLOORS
10/16 AHU-7-1, 7-2 OFFICE SPACE ALL FLOORS
HOOD B-123, B-219, B-219-1, B-229, B-317A, B, C, D.,
EXHAUST A-256, A-260, A-358, A-362, B-159, B-233, B-255
WED AHU-Q/R B105, B105-1
5/11 8:30- 9:30AM
WED AHU-S/T A106
ERROR:#REF! Clean Room Aisle
ERROR:#REF! Clean Room Aisle
5/18 ERROR:#REF! Clean Room Aisle
5/11 9:45- 10:45AM
ERROR:#REF!
WED AHU-102 A/B/C/D Clean Room Aisle
5/11 9:45- 11:45
5/19
WED AHU-108A/B Clean Room Aisle
5/11 10:45- 1:30PM
WED AHU-109 A107
5/11 1:00- 3:00PM
WED AHU-110A/B B106, B106-1, B106-2
5/11 1:00- 3:00PM B107
WED AHU-111A/B/C/D CO-B1-1 (AHU-111A/B)
5/11 3:00- 4:00PM CO-C1-1 (AHU-111C/D)
WED AHU-114 A105, A105-2
5/11 3:00- 4:00PM
ERROR:#REF! D105
MON HOLIDAY
ERROR:#REF!
WED AHU-112/113 D101, D102, D102-3, D103, CO-D-1
5/11 3:00- 5:00PM D106, D107, D108, CO-D-1
THURS AHU-115 D105
ERROR:#REF!
ERROR:#REF!
ERROR:#REF!
5/12 7:30- 8:30AM
THURS AHU-116 E104
5/12 7:30- 8:30PM
SAT AHU-103, 104, 106 MAKE UP AIR SYSTEMS AND ACID, SOLIVENT,
5/21 EF-101A/B, 102A/B, 105A/B AND HYDRIDE EXHUST
NOTE: 1. CRITICAL EQUIPMENT REQUIRES A SCHEDULED OUTAGE TO BE SECURED.
2. PLEASE REMOVE AND SECURE ALL CHEMICALS FROM THE FUME HOODS
PRIOR TO THE SCHEDULED OUTAGE.