This document is a technical specifications sheet for a solid etalon procurement. The requirement is for two solid etalon devices manufactured from fused silica with a free spectral range of 400 pm and a full width half max transmission bandwidth of 40 pm +/-10 pm. Each etalon must be mounted using Norland 61 bonding between two annular pieces of fused silica after coating, with a coating aperture of 32 mm and clear aperture exceeding 26.8 mm. The outer diameter including mounting glass ring is 45.0 +/-0.1 mm, and the total thickness is 17.018 mm ± 0.035 mm.

Performance requirements specify a center wavelength of 467.8423 nm (vacuum) at 45°C with a tolerance of +0 pm / -30 pm, a maximum transmission of greater than 80% (with a goal of >90%), and a field of view exceeding 8-9 mrad while meeting all other specifications. The etalon must operate within a temperature range of 45-60°C with a temperature tuning rate of approximately 2.9 pm/°C. Post-delivery polishing may be performed at NASA Langley Research Center to achieve the exact wavelength if testing requires adjustment. The lead time is 2 months as soon as possible, with the place of performance designated as Langley Research Center, 23681-2199.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECS:

Device: Solid Etalon Quantity: 2 Material: Fused Silica Free Spectral Range: 400 pm Full Width Half Max Transmission Bandwidth: 40 pm +/-10 pm The etalon should be mounted (bonded using Norland 61) between two annular pieces of fused silica after coating.

Coating aperture: 32 mm Clear aperture: >26.8 mm Outer diameter (including mounting glass ring): 45.0 +/-0.1 mm Thickness (including mounting glass ring): 17.018 mm ± 0.035 mm Temperature range: 45 – 60 ˚C Temperature tuning rate: ~2.9 pm/˚C Center Wavelength*: 467.8423 nm (vacuum) @ 45 ˚C o Polishing to hit the exact wavelength after testing at NASA, if required Center Wavelength Tolerance: + 0 pm / - 30 pm Max Transmission: >80% (Goal >90%) Field of View: > 8-9 mrad while still meeting all other specs

Lead Time / Period of Performance: 2 Months ARO

Place of Performance: Langley Research Center, 23681-2199