This document is a technical specifications sheet for a high vacuum gantry system intended for use in a VOiD (Vacuum of Interest Device) chamber. The system must be designed for continuous operation in high vacuum conditions of less than 10E-7 Torr, utilizing low outgassing materials exclusively, bearings cleaned and re-greased with Braycote 601EF grease or equivalent HV/UHV lubricant, integrated thermal provisions in motor design, and vacuum-compatible wire insulation such as PTFE or Kapton.

The gantry system consists of three linear stages—X, Y, and Z axes—each driven by vacuum-compatible stepper motors and lead screws with position feedback via motor encoders. The X and Y stages must provide at least 24 inches of travel in an assembled length not exceeding 32 inches, with positioning resolution of at least 6E-4 inches, individual weights not exceeding 15 pounds, and a load rating of at least 50 pounds. The Z stage must provide at least 12 inches of travel in an assembled length not exceeding 20 inches, with positioning resolution of at least 4E-6 inches, weight not exceeding 7 pounds, and a load rating of at least 50 pounds. All stages must demonstrate compatibility with high vacuum operating conditions and maintain structural integrity under specified load conditions.

View the file

Other files for this federal contract opportunity

Other files attached to High vacuum gantry for VOiD deposition system, newest first.
File Type Posted
SATPC0041765 Tab 07 Capability Statement.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications for high vacuum gantry system for VOiD chamber

1. Designed for continuous operation in high vacuum (<10E-7 Torr)

a. Low outgassing materials used exclusively

b. Bearings cleaned and re-greased with Braycote 601EF grease or equivalent

HV/UHV lubricant

c. Thermal provisions integrated into motor design to prevent overheating

d. PTFE, Kapton, or other vacuum compatible wire insulation used

2. Each linear stage to be driven by vacuum compatible (see Req.1) stepper motor and lead screw.

3. Position feedback with motor encoder for each linear stage

4. X and Y linear stages must be capable of 24 inches or more of travel without exceeding a total assembled length of 32 inches.

5. Z linear stage must be capable of 12 inches or more of travel without exceeding a total assembled length of 20 inches.

6. X and Y linear stages must have a positioning resolution of at least 6E-4 inches.

7. Z linear stage must have a positioning resolution of at least 4E-6 inches

8. X and Y linear stages must not weigh more than 15 pounds each.

9. Z linear stage must not weigh more than 7 pounds.

10. X, Y, and Z linear stages must each have a load rating of at least 50 pounds.