SATPC0041220 Tab 04 4 SOW Rev.pdf

PDF 470 KB Posted

Attached to
NTF Liquid Nitrogen Pump 12 Critical Spare Federal contract opportunity
Solicitation number
80NSSC26933864Q-R1
Issued by
National Aeronautics and Space Administration Shared Services Center

About this file

This is a Statement of Work (SOW) for procuring a fully interchangeable replacement liquid nitrogen pump for the National Transonic Facility at NASA Langley Research Center.

The procurement requires a Liquid Nitrogen Pump that is mechanically, electrically, and functionally identical to the existing Cryostar CS400/355/20L Pump (Serial Number 96013/02). The existing pump specifications include a single-stage design with a 400mm nominal impeller diameter (355mm trimmed), 20mm tip width, and 1780 rpm operation. Operating parameters include liquid nitrogen at -195°C, 5 barg maximum suction pressure, 1.4m minimum NPSH, 1300 gpm flow rate, and 180 ft differential head. The existing motor is a 405 TD NEMA-rated electric motor rated at 60 Hz, 3 phase, 480V, 100 Hp. The new pump specifications call for an LIN Transfer MCP 400/20L-1.7-CB-WB C/0 vertical centrifugal pump with a 75kW LSES280SD electric motor (4 poles, fixed speed, 480V, 60 Hz). The replacement pump must include PT100 sensors, heating cables, grease retaining chambers with N2 purge, labyrinth seals, control panels for seal gas and low pressure drop management, mechanical performance testing in cryogenic conditions, and documentation including installation, assembly checklist, and performance test reports. Spare parts include a commissioning kit for installation and start-up, with seaworth packing required. Delivery to NASA Langley Research Center Central Receiving in Hampton, Virginia, is required by June 30, 2027.

View the file

Other files for this federal contract opportunity

Other files attached to NTF Liquid Nitrogen Pump 12 Critical Spare, newest first.
File Type Posted
SATPC0041220 Tab 10 BNJ_Redacted.pdf PDF
SATPC0041220 Tab 10 RFQ OM Template_FO.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 Title: Procure Fully Interchangeable Replacement Liquid Nitrogen Pump 12

2 Background:

The National Transonic Facility is a high-pressure, cryogenic, closed-circuit wind tunnel that uses supercold nitrogen gas at high pressure to duplicate true flight aerodynamics.

The Liquid Nitrogen Pump 12 (P12) is one of the pumps that supplies liquid nitrogen to the facility. Liquid Nitrogen is stored in the 3000 Ton tank and then transferred to the 800 Ton tank. This task is to procure a fully interchangeable critical spare for P12.

3 Description of work to be performed:

This task is to procure a Liquid Nitrogen Pump with the same mechanical, electrical, and controls interfaces as the existing Cryostar CS400/355/20L Pump with Serial Number 96013/02.

3.1 Existing Pump Specifications:

- Single Stage

- 400 mm nominal impeller diameter

- 355 mm trimmed impeller diameter

- 20 mm tip width

- 1780 rpm

3.2 Operating Data

- LN2

- (-195°C) Liquid Temperature

- 5 barg Maximum Suction Pressure

- Minimum NPSH 1.4m

- 1300 gpm Flow Rate

- Differential Head 180 ft.

3.3 Existing Motor Specifications

- 405 TD, NEMA

- 60 Hz, 3 Phase, 480V, 100 Hp

- Unclog and verify orifice plug.

- Clean cable block in prep for unit assembly.

3.4 Performance Curves

3.5 New Pump Specifications

- LIN Transfer – MCP 400/20L-1.7-CB-WB C/0

Vertical centrifugal pump PT100 Sensor in lantern for seal leakage detection Heating cable for thermal barrier Grease retaining chamber with N2 purge Close warm box with N2 purge 2-chamber labyrinth seal Cold box isolation plate

- Electric motor LSES280SD of 75kW – 4 poles – fixed speed – 480V – 60 Hz Anticondensation heater 120V in separate Junction Box 3xPTC in winding 2XPT100 at Drive End bearing Grease nipples Painting type C3 according to ISO 12944-2

- Seal gas control panel (installed and fully wired onto the pump)

- Labyrinth seal Low Pressure Drop control panel according to preliminary panel drawing

No 763206054 and to preliminary P&ID No 704206221-41

- Including mechanical performance test in cryogenic conditions with LIN on duty point

- Documentation as per Cryostar standard limited to IOM, Assembly checklist and

Performance test report in PDF sent by email

3.6 Spare parts

- Commissioning Kit for Installation and Start-up

3.7 Seaworth Packing

4 Period of Performance

This valve shall be procured and delivered to Langley prior to June 30, 2027.

5 Shipping Address

NASA Langley Research Center Central Receiving 4 South Marvin Street Building 1206 Hampton, VA 23681-2199