This document is a Sources Sought pre-solicitation for relocatable facilities at RAF Fairford by the Department of the Air Force United States Air Forces in Europe - Air Forces Africa. The project involves constructing and installing multiple modular buildings, including a 4-bay 32ft x 20ft double-stack building, three 32ft x 10ft open plan/canteen units, one 24ft x 10ft open plan unit, and one 2-bay 20ft x 16ft office unit. Each unit will include specific features such as lighting, heating, power points, UPVC double-glazed windows with shutters, steel external doors, and RCD-protected consumer units.

Potential sources are required to submit a 4-page capability statement by 16:00 GMT on June 12, 2025, addressing technical expertise and geographical location. The technical submission must include recent project details from the past 4 years, specifying project descriptions, contract types, values, completion status, and client contact information. Respondents must demonstrate experience in sitework and relocatable facility construction, with a preference for firms having a physical office in the United Kingdom. The solicitation number is FA5570S0005, and interested parties can direct questions to Mr. Calin Moloiu at calin.moloiu.gb@us.af.mil or (314) 268-3482.

View the file

Other files

File Type Posted
Attach 8 ufc_1_200_01 Building Standard.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

HEADQUARTERS 501ST COMBAT SUPPORT WING (USAFE)

Modular Building Salient Characteristics

- 4 bay 32ft x 20ft (9.7m x 6m) Double stack Ground floor and first floor open plan building. Complete with Lighting, Heating, Power points, and Rcd protected consumer unit. 16 x UPVC double glazed windows with shutters, 4 X steel external doors.

- 2 x New 13 tread steel stairs and platform. (One at each end of building.)

- 3 x 32ft x 10ft (9.7m x 3m) open plan/canteen units complete with Heating, Lighting, vinyl to floor, steel external door, double glazed sliding windows with shutters, Rcd protected consumer unit.

- 1 x 24ft x 10ft (7.3m x 3m) Open plan unit with 1 x steel external door, 2 x sliding windows with shutters, heating, lighting and Rcd protected consumer unit.

- 1 x 2 bay 20ft x 16ft (6m x 4.8m) open plan office unit complete with 2 x steel external doors, 4 x UPVC double glazed windows with roller shutter, heating, lighting and Rcd protected consumer unit.

- Delivery costs with hi-ab lorries to offload and position.

- Groundwork’s for above units to include 450mm x 450mm foundation pads on each corner of the building only. (Gravel not included around surrounds of building.)

Compliance with UFC 1-200-01, 01 September 2022 implementing Change 4, 17 December 2024.