The document is a Salient Characteristics specification sheet for a handheld communications service monitor. The equipment must be a portable, battery-powered device weighing ≤11 lbs with dimensions of ≤12in X 10in X 5in, designed for comprehensive communications testing. Key technical specifications include a minimum frequency range of 1MHz-6GHz, LCD touch screen, multiple connection types (USB, Ethernet, BNC, N-Type RF), and capabilities such as Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements, modulation signal display, and WiFi with WPA security. The device must provide at least 3 hours of continuous operation, have a rugged exterior with carabiner clip compatibility, and include features like auto-testing, VNC access, and the ability to save signal recordings for historical records or training purposes.

View the file

Other files

File Type Posted
RFQ- FA301625Q6087.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Soft Carrying Case with strap for portability above 15ft elevations Rugged exterior equipment frame with loop(s) to accommodate carabiner clip for hoisting equipment above 15ft elevations

Portable package at ≤ 11lbs; compact size at ≤ 12in X 10in X 5in

Battery powered unit with no less than 3 hours continuous operation per full charge

LCD Display touch screen for ease of navigation in challenging testing environments

Duplex N-Type RF Connection

Audio input BNC connection supporting audio frequency (AF), digital and modulation signals

Audio output BNC connection providing AF signal generation

Antenna/SWR input/output bnc connection for testing lines and forward/reflected power

10 MHz test connection for verification and calibration purposes

USB connection for transfer of/saving test results and software/firmware equipment upgrades

Ethernet connection for transfer/saving test results and software/firmware equipment upgrades

Power connection for charging battery Capability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements on transmission lines

Minimum Frequency Range of 1MHz-6GHz

Ability to display AM/FM/PM Modulated signals

Auto Test Feature allowing technicians to write testing scripts per equipment type and/or location

Virtual Network Computing (VNC) capabilitiesfor accessing equipment from a laptop WiFi with WPA security capabilities to export information to stand alone laptop of receive firmware updates to testset

Capability to save signal recordings for equipment historical records or training purposes At minimum, the required equipment must have the capabilities listed above