The document is a Salient Characteristics specification sheet for a handheld communications service monitor. The equipment must be a portable, battery-powered device weighing ≤11 lbs with dimensions of ≤12in X 10in X 5in, designed for comprehensive communications testing. Key technical specifications include a minimum frequency range of 1MHz-6GHz, LCD touch screen, multiple connection types (USB, Ethernet, BNC, N-Type RF), and capabilities such as Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements, modulation signal display, and WiFi with WPA security. The device must provide at least 3 hours of continuous operation, have a rugged exterior with carabiner clip compatibility, and include features like auto-testing, VNC access, and the ability to save signal recordings for historical records or training purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ- FA301625Q6087.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Soft Carrying Case with strap for portability above 15ft elevations Rugged exterior equipment frame with loop(s) to accommodate carabiner clip for hoisting equipment above 15ft elevations
Portable package at ≤ 11lbs; compact size at ≤ 12in X 10in X 5in
Battery powered unit with no less than 3 hours continuous operation per full charge
LCD Display touch screen for ease of navigation in challenging testing environments
Duplex N-Type RF Connection
Audio input BNC connection supporting audio frequency (AF), digital and modulation signals
Audio output BNC connection providing AF signal generation
Antenna/SWR input/output bnc connection for testing lines and forward/reflected power
10 MHz test connection for verification and calibration purposes
USB connection for transfer of/saving test results and software/firmware equipment upgrades
Ethernet connection for transfer/saving test results and software/firmware equipment upgrades
Power connection for charging battery Capability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements on transmission lines
Minimum Frequency Range of 1MHz-6GHz
Ability to display AM/FM/PM Modulated signals
Auto Test Feature allowing technicians to write testing scripts per equipment type and/or location
Virtual Network Computing (VNC) capabilitiesfor accessing equipment from a laptop WiFi with WPA security capabilities to export information to stand alone laptop of receive firmware updates to testset
Capability to save signal recordings for equipment historical records or training purposes At minimum, the required equipment must have the capabilities listed above