This document provides salient characteristics for an EFD induction system procurement by the Defense Logistics Agency Land and Maritime under solicitation number SPMYM223Q2155. The system requires a continuous output of 50kW with a maximum of 80kW at a 50% duty factor over 10-minute cycles and an output power regulation range of 2-100%. The main power unit operates from a 400-480V, 50/60Hz supply and requires a minimum water flow of 21 liters per minute at temperatures up to 35 degrees Celsius and pressures from 4.5-6 bar. The enclosure has external dimensions of 345 x 708 x 453 mm, weighs 80kg, and has an IP54 rating. Linear or manual scanning coils must have an 8-inch width and copper tube construction.

View the file

Other files for this federal contract opportunity

Other files attached to EFD INDUCTION SYSTEM, newest first.
File Type Posted
23Q2155 EFD INDUCTION SYS.pdf PDF
SOLE SOURCE_REDACTED.pdf PDF
32143926-CDRL NRTL CERTIFICATION_Redacted.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS FOR

EFD INDUCTION SYSTEM

JML’S 3214-3925, 3926 & 3927

8/2/2023

• MAIN POWER UNIT OUTPUT

o Continuous power output=50kW o Maximum output power= 80kW o Duty factor/Cycle time=50%/10min o Output power regulation range=2-100% o Frequency Range=10-25kHz o HHT 400 power cable length=5M/10M o NRTL completed on main cabinet.

• MAIN POWER UNIT SUPPLY

o Supply voltage range=3 x 400-480 +or-10% o Frequency=50/60Hz o Nominal voltage=400 V o Nominal line current=89A (RMS) o Max line current intermittent=134A (RMS) o Nominal apparent power=62kVA o Maximum apparent power=93kVA o Recommended fuse=100 Amp o Mains cable length=5M

• COOLING

o Water consumption, min=21l/min o Water inlet temperature=Max 35 degrees Celsius o Water Pressure min/max=4.5-6 bar o Cooling water quality PH=Between 7.0-9.0

• ENCLOSURE

o Ambient operating temp=+5 degrees Celsius to +50 degrees Celsius o Outer dimensions (W x D x H)=345 x 708 x 453 mm o Weight with HHT 400/5M=80 kg (Approximately) o Enclosure protection=IP 54 o Color=RAL 7021 Black o HHT 400 outer dimension (L x OD)=183 x 77 mm o HHT 400 weight without handle=6kg

• Transformer o Hand transformer with 10 meter long output cable

• LINEAR/MANUAL SCANNING COILS

o Must heat and 8” wide band in a manual scanning condition o Copper tube construction o Miter joints silver brazed o Electrical contacts are silver-plated