Salient Characteristics: Closed Circuit Security Camera System Requirements Item QTY Comments
0001 HDCVI CAMERA 14
Type: Fixed Dome Resolution: 1080p HD Video Resolution (1920 x 1080) Connection: Coaxial Cable & Conduits Features: Motion Detection; 24 IR LEDs for Night Vision Wide Angle view; 180 Degree View with zoom capabilities Mount - Ceiling or Wall Mountable IP66 Weatherproof Housing - Indoor / Outdoor Vandal Resistant
0002 42 inch security camera monitor
Display: 42" viewable image with 16:9 aspect ratio; Resolution: Max 1080P (1920 x 1080); Color resolution: approx. 16.7 million; Response time: 5ms;
Contrast Ratio (DCR): 20,000,000:1; Power Source: Universal
100~240VAC,50/60HZ.
16 Tera Byte
External Hard Drive Cloud
Minimum specification: Intel PentiumN3710 quad-core 1.6GHz processor with 4GB DDR3L memory; Comprehensive security through password protection and AES 256 Bit Volume encryption;
0004 HDCVI Digital Video Recorder
1080P High Definition 32CH Digital Video Recorder - Titanium Series / HDMI Output / H.246 Compression / Audio Input / Motion Activated / USB Backup / Remote Control / NetViewer Software **16TB Hard DriveDigital Video Recorder capable of storing 30 days of recording and able to copy footage on a thumb drive or disc.
POWER
DISTRIBUTION
PANEL
At least one power distribution panels are required to power the 14 cameras. The power distribution panels require a minimum of one-year warranty.
0006 INSTALLATION
Contractor shall install replacement security cameras at existing locations in building 520. The contractor is responsible for all wiring, and materials needed to complete installation, and will conduct a site visit to determine appropriate coverage based on floorplans submitted by the customer.
Wiring for cameras will be out of sight through the ceiling, wall, or installed in a minimum of ¼ inch conduit near the ceiling.