Salient Characteristics - 3D Systems.pdf
PDF 102 KB Posted
- Solicitation number
- W911QX24Q0150
About this file
This document is a Salient Characteristics document for the replacement parts and reinstallation of the Government-owned Prox320 Machine at the Army Research Directorate (ARD) of the DEVCOM Army Research Laboratory (ARL). The machine requires replacement parts and reinstallation due to water damage from a contaminated air supply. The Contractor shall provide the specified replacement parts, remove the current damaged parts, install the new parts, and recalibrate the system to restore functionality. The required parts include a collimator, IntelliScan assembly, f-theta objective, sensors, pneumatic valves, and silencers. The Contractor shall also provide labor, documentation, tools, and transportation to complete the repair and maintenance. Delivery of the replacement parts is required within 90 days of contract award, with the reinstallation to be completed 90 days after the parts delivery. This requirement will be procured via a sole source contract with 3D Systems, Inc.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Replacement Parts & Reinstallation for the Government-owned Prox320 Machine.
Aberdeen Proving Ground, MD
POC: Alexander Butler, (410) 306-0751
The Army Research Directorate (ARD) of the DEVCOM Army Research Laboratory (ARL) currently owns a machine named the 3D System’s Prox320 Machine. This machine provides support to ARL’s Essential Research
Program (ERP): Science of Additive Manufacturing for Next Generation Munitions (SAMM) and is imperative for current and future projects at ARL. The ARD of DEVCOM ARL requires replacement parts and reinstallation of the
Prox320 Machine to restore functionality after water damage occurred from a contaminated air supply. The agreement shall consist of purchase of replacement parts, removal of current parts and installation of new parts at
Aberdeen Proving Ground (APG) in Aberdeen Proving Ground, MD, for the Government-owned Prox320 Machine.
The Contractor shall furnish all labor, tools, and supplies to perform parts removal, parts reinstallation, and maintenance of the Prox320 Machine under the duration of this contract.
The Contractor shall provide the following replacement parts:
Part Description Part Number Quantity
R/Collimator f60, for QBH-compatible connector, water cooled, YLORCHX1060XX1
151459 1
Full assy: IntelliScan III 20, PC interface board RTC5 Express, shielded 5 data cable, mounting kit
151460 1
420 f-theta-objective for 1.030-
1.090 nm – 120187
151466 1
Reed Sensor, Bellow = AM350, VABKF16/KF50/RS
151627 2
Pneumatic valve VAV50KFP 151474 1
Pneumatic valve VAV25KFP 151473 2
Silencieux 1/8” / Silencer 1/8” 15-2555 5
The Contractor shall provide all labor, documentation, repair and maintenance supplies, tools, calibration equipment, transportation, and scheduled visits to repair the Government-owned Prox320 Machine. The Contractor shall provide removal of the damaged parts of the machine, replacement and installation of the new parts, and maintenance services as detailed in section C.3 and in the tables below.
The Contractor shall remove the current damaged parts of the Prox320 Machine to prepare for the repair and installation.
The Contractor shall restore functionality to the machine by replacing the damaged parts with new parts.
The Contractor shall ensure the machine is clear of water and can operate correctly. Recalibration of the system shall be done by the Contractor to ensure the machine is operating correctly.
The Contractor shall supply technician(s) for the on-site visit(s) totaling 24 working hours (or 3 working days).
Antiterrorism/ Operations Security
Access and general protection/security policy and procedures. This standard language is for Contractor employees with an area of performance within Army controlled installation, facility, or area. Contractor and all associated sub-contractors employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security
Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-
9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection
Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.
For Contractors that DO NOT require CAC, but require access to a DoD facility or installation. Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National
Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB)
(Army Directive 2014-05/AR 190-13), applicable installation, facility and area commander installation/facility access and local Security policies and procedures (provided by Government Representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.
Contracting Officer:
5/6/2024
X Phillip J. Amador
Contracting Officer (KO)
Signed by: AMADOR.PHILLIP.JOSEPH.1178373494
File details come from the government source that posted it. Updated .