Sacramento Peak Preliminary Design Drawing Final 03302019.pdf
PDF 5 MB Posted
- Solicitation number
- 12760420Q0025
- Issued by
-
Department of Agriculture Forest Service
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers.xlsx | XLSX spreadsheet | |
| Request for Quote.docx | DOCX document | |
| Bill of Materials.XLSX | XLSX spreadsheet | |
| Sacramento Peak - Specification Package 3 Final - 03302019.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
/3 /2
T1 1 8
D
IS
TR
IC
T
ST
A T
E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U R
E
F O
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
Te d
Su m ne rs
Li n co ln
N a ti o n al
F o re st
N ew
M ex ic o
S A
C R
A M
E N
T O
P E
A K
LINCOLN NATIONAL FOREST
Sacramento Peak
U.S. DEPARTMENT OF AGRICULTURE FOREST SERVICE
FACILITY IMAGE VICINITY MAP
Directions to Sacramento Peak
From Alamogordo, New Mexico
1. Head north on N White Sands Blvd toward E 10 th St go 3 mi
2. Turn right onto US-82 E go 9 mi
3. Turn right onto 63 Rd/Karr Canyon Rd go 3.1 mi
4. Continue onto Forest Rd 63 go 4.2 mi
5. Turn right onto Sunspot Hwy go 7.3 mi
6. Turn left go 0.7 mi
7. Continue onto Forest Rd 64 go 3.6 mi
8. Facility will be on the left
Latitude: 32°44'49.00"N
Longitude: 105°45'39.00"W
Elevation: 9,539 ft. AMSL
Internal Grounding
Typical Installation Detail
Typical Installation Detail
Title Sheet
Communications Shelter Layout
External Grounding
T1
A1
E4
G1
G2
E3
TITLESHEET NO. DWG. NO.
SHEET INDEX
Preliminary Design
03/30/2019
03/30/2019
03/30/2019
03/30/2019
03/30/2019
03/30/2019
Revision Date
AREA REFERENCE MAP
SYMBOL
INTERSTATE HIGHWAY
U.S. HIGHWAY
STATE HIGHWAY
DESCRIPTIONSYMBOL
STATE CAPITOL
FACILITY LOCATION
BLM FIELD OFFICE
DESCRIPTION
Sacramento Peak Sacramento Peak
Facility Layout3 C1 03/30/2019
Electrical One-Line4 E2 03/30/2019
/3 /2
A-1 2 8
E
D
C
B
A
E
D
C
B
A
654321 654321
E
D
C
B
A
E
D
C
B
A
654321 654321
O R
G U
N
IT
ST
A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T e d
S u m n e rs
N e w M e xi co
S A
C R
A M
E N
T O
P E
A K
COMMUNICATIONS SHELTER LAYOUT
Preliminary Design
1/4" = 1'
0 ft. 3 ft. 5 ft. 10 ft.0 ft. 3 ft. 5 ft. 10 ft.
N
Li n co ln
N at io n al F o re stGenerator Room Generator Room
Replace Consumer
Grade HVAC Unit
New Commercial
Grade HVAC Unit
3 ft.
Remove Empty Cabinet
(E) Fluorescent Lights
2 ft. 6 in.
3 ft. 6 in.
(E) Master
Ground Bus Bar
(E) Electrical Distribution Panel
Install New Door Seal
Seal Exterior Cracks and Repaint Shelter
EXISTING PROPOSED
Remove Existing Wire
Cable Runway System
Remove/Replace
Existing Equipment
Racks and Cabinets
Label All Circuit
Breakers and Outlets
Install Exterior Light on Timer 3
3Anchor Racks to Floor (x3)
Relocate Equipment into New Equipment Racks (x5)
Cable Installation on
Equipment Racks (x3)
New 72-inch High 19-inch EIA
Equipment Racks (x5)
Install New12-inch
Cable Ladder System
Equipment Rack
Installation and Spacing 3
G2
G2 6
Install New 20 Amp Simplex Twist Lock Receptacles Above Each Rack (L5-20R)
Install, Route, and Secure Cabling On
Cable Ladder
Install Protective Covers on Lights
Timer SwitchTimer SwitchTimer Switch
L5-20RL5-20R
L5-20RL5-20R
L5-20RL5-20R
L5-20RL5-20R
L5-20RL5-20R
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
/3 /2
C1 3 8
E
D
C
B
A
E
D
C
B
A
654321 654321
E
D
C
B
A
E
D
C
B
A
654321 654321
O R
G U
N
IT
ST
A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T e d
S u m n e rs
N ew
M ex ic o
S A
C R
A M
E N
T O
P E
A K
FACILITY LAYOUT
Preliminary Design
1" = 20'
0 ft. 12 ft. 20 ft. 40 ft.0 ft. 12 ft. 20 ft. 40 ft.
N
Li n co ln
N at io n al F or es tExisting Fire Lookout Tower
Existing Chain-Link Fence
Existing Equipment Shelter
Existing Utility Pole with Transformer
Existing Utility Pole with Meter
Access Road
Generator
Room
Existing Ice Bridge
L P
G L P
G
Existing Propane Tank
USDA or BLM to Remove/Replace Existing Propane Tank
Contractor to Ground Tank if Replaced
Contractor to Clear Vegetation out of Fenced
Compound and within 6 Feet of Fence
Install New External Grounding System and Components
E3E3
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
E2 4 8
/3 /2
E
D
C
B
A
E
D
C
B
A
654321 654321
E
D
C
B
A
E
D
C
B
A
654321 654321
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
Electrical One-Line
(To Be Provided By Contractor)
O R
G U
N
IT
ST
A
T E
Li n co ln
N at io n al F o re st N ew M ex ic o
S A
C R
A M
E N
T O
P E
A K
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
/3 /2
E3 5 8
E
D
C
B
A
E
D
C
B
A
654321 654321
E
D
C
B
A
E
D
C
B
A
654321 654321
O R
G U
N
IT
ST
A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T e d
S u m n e rs
N ew
M ex ic o
S A
C R
A M
E N
T O
P E
A K
EXTERNAL GROUNDING PLAN
Preliminary Design
3/32" = 1'
0 ft. 6 ft. 10 ft. 20 ft.0 ft. 6 ft. 10 ft. 20 ft.
N
Li n co ln
N at io n al F or es t
Existing Fire
Lookout Tower
Existing Chain-Link Fence
Existing Utility Pole with Transformer
Existing Utility
Pole with Meter
Generator Room
3 ft.
L P
G L P
G
Ground Each Tower Leg to New Grounding System 9
Ground Each Corner Fence Post/Fabric and
Deterrent Wires to New Grounding System
Install Ground Kits on Each RF Cable at Base of Tower 21
Ground Gateposts and Gate to New Grounding System
Install New Tower Ground Bus Bar 3
8Install New Tower Ground Ring
7 Install New Shelter Ground Ring
Ground Electrical Distribution Ground Bus to New Ground Ring
Interconnect Tower and Shelter Ground Rings
G1
G1Replace MGB Grounding Conductors with Two #2 AWG, Bare, Tinned, Solid with Two-Hole Connections to MGB
Replace EGB Grounding Conductors with Two #2 AWG, Bare, Tinned, Solid with Exothermic Welds to EGB
G1
G1
Install Ground Kits on Each RF Cable Prior to Entering Shelter21
Ground Ice Bridge and Posts to New Ground Ring14
USDA or BLM to Remove/Replace Existing Propane Tank
Contractor to Ground Tank if Replaced
G1
G1
G1
G1
G1
G1
G1 G1Design, Provide, Install Primary Surge
Protection Device (SPD TYPE 1 SAD/MOV)3
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
/3 /2
E4 6 8
E
D
C
B
A
E
D
C
B
A
654321 654321
E
D
C
B
A
E
D
C
B
A
654321 654321
O R
G U
N
IT
ST
A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T e d
S u m n e rs
N e w M e xi co
S A
C R
A M
E N
T O
P E
A K
INTERNAL GROUNDING
Preliminary Design
1/4" = 1'
0 ft. 3 ft. 5 ft. 10 ft.0 ft. 3 ft. 5 ft. 10 ft.
N
Li n co ln
N at io n al F o re st
Generator Room
4-inch Gap Between IPG Conductors
Replace MGB Grounding Conductors with Two #2 AWG, Bare, Tinned, Solid with Two-Hole Connections to MGB
17Rack Ground Bus Bars in Each Equipment Rack (x5)
Ground Cable Ladder to MGB
Ground Internal Entrance Panel to MGB
Bond Cable Ladder Segments Together At Each Joint
New Internal Perimeter Ground (IPG)
Install Surge Protection Devices on Each RF Cable
G1
G1Design, Provide, Install Primary Surge Protection Device (SPD TYPE 1 SAD/MOV)3
Ground Distribution Panel to IPG12
New Internal Perimeter Ground (IPG) 16
Ground HVAC to IPG 12
To SGR
Ground Rack Mounted Equipment (x5) 18
Ground Electrical Distribution Ground Bus to New Ground Ring2To SGR
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
G1
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T Y
P
IC
A L
D R
A W
IN
G
/3 /2
C o n tr a c to r
T e c h n ic a l E v a lu a ti o n
D e v e lo p m e n t S e rv ic e s L
L C
Te d
Su m ne rs
7 8
TYPCAL FACILITY GROUNDING DETAILS
RF CABLE GROUND KIT
TOWER GROUND BUS BAR (TGB)
NOTE: EXOTHERMIC WELD CONNECTIONS BELOW GRADE
#2 AWG OR COARSER, BARE, SOLID, TINNED
COPPER WIRE USING TWO-HOLE CONNECTION W/
STAINLESS STEEL HARDWARE TO GRIPSTRUT
RF SURGE PROTECTION DEVICE
MASTER GROUND BUS BAR (MGB)
EXTERNAL GROUND BUS BAR
(EGB)
RF CABLE GROUND KIT
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING TGB TO
TOWER GROUND RING
EXOTHERMIC WELD
CONNECTIONS TO POSTS
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING MGB TO
SHELTER GROUND RING
EXOTHERMIC WELD
CONNECTIONS TO POSTS
9 TOWER LEG GROUNDING
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING EACH
TOWER LEG TO TOWER GROUND
RING
TOWER GROUND RING
#2 AWG TINNED, SOLID COPPER
CONDUCTOR
SHELTER GROUND RING
#2 AWG TINNED, SOLID COPPER
CONDUCTOR
SELF-SUPPORTING ICE
BRIDGE GROUNDING
13GROUND SHELTER
FRAME AT EACH CORNER
Grade
EXTERNAL GROUND BUS BAR (EGB) DETAIL
RF CABLE ENTRANCE
PANEL AND OTHER
ANCILLARY DEVICES WITH
SINGLE-HOLE IRREVERSIBLE
HIGH-COMPRESSION LUGS
NOTE: CONTRACTOR TO USE LISTED ANTIOXIDANT AGENT
BETWEEN MECHANICAL BONDING CONNECTIONS.
RF CABLE GROUND KITS OR OTHER DEVICES WITH
TWO-HOLE IRREVERSIBLE HIGH-COMPRESSION LUGS
4.6"
7"
0.25"
#2 AWG, SOLID TINNED COPPER CONDUCTORS TO SHELTER
GROUND RING WITH EXOTHERMIC OR IRREVERSIBLE HIGH
COMPRESSION CONNECTIONS
TINNED COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
12"
4"
EXTERNAL GROUND BUS BAR (EGB) DETAIL
RF CABLE ENTRANCE
PANEL AND OTHER
ANCILLARY DEVICES WITH
SINGLE-HOLE IRREVERSIBLE
HIGH-COMPRESSION LUGS
NOTE: CONTRACTOR TO USE LISTED ANTIOXIDANT AGENT
BETWEEN MECHANICAL BONDING CONNECTIONS.
RF CABLE GROUND KITS OR OTHER DEVICES WITH
TWO-HOLE IRREVERSIBLE HIGH-COMPRESSION LUGS
4.6"
7"
0.25"
#2 AWG, SOLID TINNED COPPER CONDUCTORS TO SHELTER
GROUND RING WITH EXOTHERMIC OR IRREVERSIBLE HIGH
COMPRESSION CONNECTIONS
TINNED COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
12"
4"
TOWER GROUND BUS BAR (TGB) DETAIL
RF CABLE
GROUND KIT TINNED COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
#2 AWG, SOLID TINNED COPPER
CONDUCTORS TO TOWER GROUND RING WITH EXOTHERMIC
OR IRREVERSIBLE HIGH COMPRESSION CONNECTIONS
4"
12"
0.25"0.25"
0.25"0.25"
OPTION 2: TINNED COPPER BUS
BARS MAY BE FASTENED
DIRECTLY TO TOWER WITH NO
ISOLATORS USING BEAM CLAMPS
OR ROUND MEMBER ADAPTERS
OPTION 1: BARE AND TINNED COPPER
BUS BARS FASTENED TO THE TOWER
WITH ISOLATORS (PREFFERED)
TOWER GROUND BUS BAR (TGB) DETAIL
RF CABLE
GROUND KIT TINNED COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
#2 AWG, SOLID TINNED COPPER
CONDUCTORS TO TOWER GROUND RING WITH EXOTHERMIC
OR IRREVERSIBLE HIGH COMPRESSION CONNECTIONS
4"
12"
0.25"
0.25"
OPTION 2: TINNED COPPER BUS
BARS MAY BE FASTENED
DIRECTLY TO TOWER WITH NO
ISOLATORS USING BEAM CLAMPS
OR ROUND MEMBER ADAPTERS
OPTION 1: BARE AND TINNED COPPER
BUS BARS FASTENED TO THE TOWER
WITH ISOLATORS (PREFFERED)
MASTER GROUND BUS BAR (MGB) DETAIL
INTERNAL PERIMETER GROUND
#2 AWG Green-Jacketed (Two-Hole)
NOTE:
CONTRACTOR TO USE LISTED ANTIOXIDANT AGENT BETWEEN MECHANICAL BONDING
CONNECTIONS.
RF SURGE PROTECTION DEVICES
#6 AWG Green-Jacketed (Single-Hole)
4.6"
7"
0.25"
#2 AWG, SOLID TINNED COPPER CONDUCTOR TO
SHELTER GROUND RING WITH EXOTHERMIC OR
IRREVERSIBLE HIGH COMPRESSION CONNECTIONS
16 16
RACK GROUND BUS BARS
#2 AWG Green-Jacketed (Two-Hole)
17 13 ANCILLARY DEVICE GROUNDING
#6 AWG Green-Jacketed (Two-Hole)
BARE COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
INTERNAL PERIMETER GROUND
#2 AWG Green-Jacketed (Two-Hole)
MASTER GROUND BUS BAR (MGB) DETAIL
INTERNAL PERIMETER GROUND
#2 AWG Green-Jacketed (Two-Hole)
NOTE:
CONTRACTOR TO USE LISTED ANTIOXIDANT AGENT BETWEEN MECHANICAL BONDING
CONNECTIONS.
RF SURGE PROTECTION DEVICES
#6 AWG Green-Jacketed (Single-Hole)
4.6"
7"
0.25"
#2 AWG, SOLID TINNED COPPER CONDUCTOR TO
SHELTER GROUND RING WITH EXOTHERMIC OR
IRREVERSIBLE HIGH COMPRESSION CONNECTIONS
16 16
RACK GROUND BUS BARS
#2 AWG Green-Jacketed (Two-Hole)
17 13 ANCILLARY DEVICE GROUNDING
#6 AWG Green-Jacketed (Two-Hole)
BARE COPPER GROUND BUS BAR
(TYPICAL: 4" x 12" x 1/4" )
(MINIMUM: 2" x 12" x 1/4" )
INTERNAL PERIMETER GROUND
#2 AWG Green-Jacketed (Two-Hole)
DETERRENT WIRE GROUNDING CLAMP
(1 OF 3)
FENCE FABRIC GROUNDING CLAMP
(1 OF 3)
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE FABRIC
TO GROUND CONDUCTOR
CONNECT FENCE BONDING CONDUCTOR
TO FENCE GROUNDING CONDUCTOR
USING EXOTHERMIC WELD
FENCE CORNER GROUNDING DETAIL
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE POST TO
SHELTER OR TOWER GROUND RING
#6 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE
RAIL TO FENCE POST WITH
EXOTHERMIC WELDS
DETERRENT WIRE GROUNDING CLAMP
(1 OF 3)
FENCE FABRIC GROUNDING CLAMP
(1 OF 3)
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE FABRIC
TO GROUND CONDUCTOR
CONNECT FENCE BONDING CONDUCTOR
TO FENCE GROUNDING CONDUCTOR
USING EXOTHERMIC WELD
FENCE CORNER GROUNDING DETAIL
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE POST TO
SHELTER OR TOWER GROUND RING
#6 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING FENCE
RAIL TO FENCE POST WITH
EXOTHERMIC WELDS
GROUNDING SYSTEM INSPECTION WELL
3/4" CRUSHED
STONE OR EQUAL
5/8" DIA. X 10'-0" LONG COPPER
CLAD GROUND ROD
EXOTHERMIC WELD
CONNECTION (TYPE GT)
#2 AWG OR COARSER, BARE, SOLID,
TINNED, COPPER CONDUCTOR
EXOTHERMIC WELD CONNECTION
TO
GROUND BAR.
SHELTER AND TOWER
GROUND RINGS
#2 AWG OR COARSER, BARE, SOLID,
TINNED COPPER WIRE TEST LOOP
EXTENSION
10" DIA. X 30" DEEP INSPECTION WELL.
#2 AWG OR COARSER, BARE,
SOLID, TINNED COPPER WIRE
EXOTHERMIC WELD
CONNECTION TO GROUND ROD.
B E
L O
W G
R A
D E
M A
X
7 8
GROUNDING SYSTEM INSPECTION WELL
3/4" CRUSHED
STONE OR EQUAL
5/8" DIA. X 10'-0" LONG COPPER
CLAD GROUND ROD
EXOTHERMIC WELD
CONNECTION (TYPE GT)
#2 AWG OR COARSER, BARE, SOLID,
TINNED, COPPER CONDUCTOR
EXOTHERMIC WELD CONNECTION
TO
GROUND BAR.
SHELTER AND TOWER
GROUND RINGS
#2 AWG OR COARSER, BARE, SOLID,
TINNED COPPER WIRE TEST LOOP
EXTENSION
10" DIA. X 30" DEEP INSPECTION WELL.
#2 AWG OR COARSER, BARE,
SOLID, TINNED COPPER WIRE
EXOTHERMIC WELD
CONNECTION TO GROUND ROD.
B E
L O
W G
R A
D E
M A
X
7 8
MECHANICAL GROUND
CONNECTION DETAILS
ANCILLARY DEVICE
BONDING
SURFACE OR BUS
BAR
REMOVE PAINT (IF PRESENT) AND APPLY A LISTED
ANTIOXIDANT COMPOUND BETWEEN MECHANICAL
CONNECTIONS
TWO-HOLE
CONNECTOR
NOTE:
USE UL-467 LISTED IRREVERSABLE HIGH COMPRESSION CRIMP
CONNECTORS FASTENED WITH STAINLESS STEEL THRU BOLTED
HARDWARE INCLUDING STAR AND LOCKWASHERS
SINGLE-HOLE
CONNECTOR
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING EACH
GATEPOST TO THE SHELTER OR
TOWER GROUND RING
#6 AWG FLEXIBLE,
STRANDED COPPER
CONDUCTOR BONDING
EACH GATE TO GATEPOST
#6 AWG TINNED, SOLID
COPPER CONDUCTOR
BONDING FENCE RAIL
TO GATEPOST WITH
EXOTHERMIC WELDS
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING EACH
GATEPOST TO THE SHELTER OR
TOWER GROUND RING
#6 AWG FLEXIBLE,
STRANDED COPPER
CONDUCTOR BONDING
EACH GATE TO GATEPOST
#6 AWG TINNED, SOLID
COPPER CONDUCTOR
BONDING FENCE RAIL
TO GATEPOST WITH
EXOTHERMIC WELDS
GATE GROUNDING DETAIL
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING EACH
GATEPOST TO THE SHELTER OR
TOWER GROUND RING
#6 AWG FLEXIBLE,
STRANDED COPPER
CONDUCTOR BONDING
EACH GATE TO GATEPOST
#6 AWG TINNED, SOLID
COPPER CONDUCTOR
BONDING FENCE RAIL
TO GATEPOST WITH
EXOTHERMIC WELDS
GATE GROUNDING DETAIL
EXOTHERMIC WELD CONNECTION DETAILS
TYPE GT
THROUGH CABLE TO
TOP OF GROUND ROD
TYPE HS
HORIZONTAL CABLE TAP
TO HORIZONTAL STEEL
SURFACE OR PIPE
TYPE TA
TEE OF HORIZONTAL
RUN AND TAP CABLES
TYPE XB
CROSS OF
HORIZONTAL CABLES.
LAPPED AND NOT CUT.
TYPE VN
HORIZONTAL CABLE
TAP TO VERTICAL
STEEL SURFACE OR
THE SIDE OF
HORIZONTAL PIPE
TYPE VS
CABLE TAP DOWN AT 45°
TO VERTICAL STEEL
SURFACE OR SIDE OF
HORIZONTAL OR
VERTICAL PIPE.
TYPE NC
THROUGH AN TAP
CABLES TO GROUND
ROD
EXOTHERMIC WELD CONNECTION DETAILS
TYPE GT
THROUGH CABLE TO
TOP OF GROUND ROD
TYPE HS
HORIZONTAL CABLE TAP
TO HORIZONTAL STEEL
SURFACE OR PIPE
TYPE TA
TEE OF HORIZONTAL
RUN AND TAP CABLES
TYPE XB
CROSS OF
HORIZONTAL CABLES.
LAPPED AND NOT CUT.
TYPE VN
HORIZONTAL CABLE
TAP TO VERTICAL
STEEL SURFACE OR
THE SIDE OF
HORIZONTAL PIPE
TYPE VS
CABLE TAP DOWN AT 45°
TO VERTICAL STEEL
SURFACE OR SIDE OF
HORIZONTAL OR
VERTICAL PIPE.
TYPE NC
THROUGH AN TAP
CABLES TO GROUND
ROD
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
PRIMARY SPD
PRIMARY SURGE PROTECTION DEVICE (SPD) TYPICAL
SURGE PROTECTION DEVICE
(SPD TYPE 1 SAD/MOV
METER
MAIN SERVICE
DISCONNECT
ELECTRICAL
DISTRIBUTION
PANEL
TYPE 3 SPD OPTIONAL WHEN
GREATER THAN 10 CONDUCTOR
FEET FROM PANELBOARD
CRITICAL
LOADS
ELECTRICAL SERVICE
ENTRANCE 240/120 VAC SINGLE
PHASE OR 208/120 VAC 3 PHASE
TO ALARMS
PANEL
(RECOMMENDED)
H TYPE 3 SPD
AT EQUIPMENT
SEE SECTION 13 34 18
2 MASTER GROUND
BUS BAR (MGB
2NEUTRAL-TO-GROUND BOND
EXOTHERMIC WELD CONNECTION (TYPE NC)
SHELTER GROUND RING 7
#2 AWG, TINNED SOLID
COPPER CONDUCTOR
NON-CRITICAL
LOADS
NON-CRITICAL
LOADS
DEDICATED 20-AMP CIRCUIT
TO EACH RADIO/ EQUIPMENT
RACK/DISPATCH EQUIP.
H
N
G1
G1
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
G2
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
C H
K 'D
B Y
D E
S
IG
N O
F F
IC
E
D E
S
IG
N E
D B
Y
P R
O J E
C T
N O
D R
A W
N B
Y
A P
P R
O V
E D
B Y
D A
T E
T Y
P
IC
A L
D R
A W
IN
G
/3 /2
C o n tr a c to r
T e c h n ic a l E v a lu a ti o n
D e v e lo p m e n t S e rv ic e s L
L C
Te d
S um ne rs
8 8
UPPER TOWER GROUND BUS BAR (TGB) DETAIL
RF CABLE GROUND KIT
TINNED COPPER GROUND BUS BAR
(TYPICAL: 2" x 12" x 1/4" )
#2 AWG, SOLID TINNED COPPER
CONDUCTOR BONDED TO VERTICAL TOWER MEMBER WITH EXOTHERMIC WELD
OR LISTED PIPE CLAMP FOR ROUND MEMBER / BEAM CLAMP FOR ANGLE MEMBER
2"
0.25"0.25"
0.25"0.25"
TINNED COPPER BUS BAR
FASTENED DIRECTLY TO
TOWER WITH NO ISOLATORS
BARE COPPER BUS BAR
FASTENED TO TOWER WITH
1.5 kV ISOLATORS
G2
G2
Upper Tower Ground Bus Ba Bonded to Vertical Tower
Member
Mid-Tower Ground Bus Bar Bonded to Vertical Tower
Member (Required on towers >200 ft.
in 100-foot Increments)
Tower Ground Bus Bar Bonded to Tower Ground Ring
ShelterShelter
TOWER GROUND BUS BAR (TGB)
TOWER LEG GROUNDING
#2 AWG TINNED, SOLID COPPER CONDUCTOR BONDING
EACH TOWER LEG TO TOWER GROUND RING
Conductors sleeved in f lexible PVC conduit
#2 AWG TINNED, SOLID COPPER
CONDUCTOR BONDING TGB TO
TOWER GROUND RING
TOWER GROUNDING DETAIL2
G2
G2
TOWER GROUND RING
#2 AWG TINNED, SOLID
COPPER CONDUCTOR
SHELTER GROUND RING
#2 AWG TINNED, SOLID
COPPER
CONDUCTOR
Exothermic Weld
Typical
Daniels VHF Repeater (21.9 lbs.)
Daniels VHF Repeater (21.9 lbs.)
Daniels TN445 Amp (10 lbs.)
Daniels TN445 Amp (10 lbs.)
Telewave Duplexer TPRD- 1554 UHF (19 lbs.)
Telewave Duplexer TPRD- 1554 UHF (19 lbs.)
Motorola Quantar – UHF (55 lbs.)
MOTO
ROLA
OF
F
O N
MOTO
ROLA
OF
F
O N
Motorola Quantar – UHF (55 lbs.)
MOTO
ROLA
OF
F
O N
30 in.
Minimum Workspace
From Furthest Extending
Device
30 in.
Minimum Workspace
From Furthest Extending
Device
84-inch High, 19-inch EIA Equipment Rack
TYPICAL EQUIPMENT RACK AND RADIO EQUIPMENT INSTALLATION
2 2
G2
G2
17 Rack Ground Bus Bar
17"
16.5"
14.75"
84-inch High, 19-inch EIA Equipment Rack (87 lbs.)
TOTAL WEIGHT = 208.9 lbs.
Rack Base Dimensions:
1.25 ft. x 1.71 ft. =2.14 ft2
Floor Load = 97.62 lbs. ft2
Telewave Duplexer TPRD-4546 UHF (16 lbs.)
Telewave Duplexer TPRD-4546 UHF (16 lbs.)
Daniels Power Supply
Daniels Repeater
Motorola Quantar
Ground All Devices to
RGB with #6 AWG, Stranded Green-
Jacketed Grounding
Conductors
To MGB
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
IC
E
U .S
D
E P
A R
T M
E N
T O
F A
G R
IC
U
L T
U
R E
S T
S E
R V
| Sacramento Peak Preliminary Design Drawing Final 03302019.vsdx |
| T1 |
| A1 |
| C1 |
| E2 |
| E3 |
| E4 |
| G1 |
| G2 |
File details come from the government source that posted it. Updated .