About this file

This solicitation requests quotes for an alarmed protected distribution system. The Air Force Oklahoma City Air Logistics Complex at Tinker Air Force Base is seeking one singlemode interceptor port with LC loopback module, fiber optic patch cords totaling 3 meters, 450 feet of 2-inch rigid conduit, and 500 feet of 48-strand singlemode fiber optic cable to be run in the conduit. The alarmed protected distribution system must provide 24/7/365 monitoring for network cable tampering, eliminate daily inspections, include smart filtering to prevent false alarms, allow for plug-and-protect rapid deployment, feature automatic configuration to remove manual tuning, and interface with an existing Vindicator five intrusion detection system. The contractor will also supply all original equipment manufacturer manuals and installation. Quotes for this 100% small business set-aside are due under solicitation number FA8139.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)

TINKER AIR FORCE BASE OKLAHOMA

Item Description

S24-004 Alarmed Protected Distribution System

76 SWEG requesting to purchase one (1) Interceptor Alarmed Protected Distribution System (PDS) or Equal with the following specifications:

• One (1) 2 Port Singlemode Interceptor.

• One (1) FIS LC Loopback Module.

• One (1) SM 9/125um Fiber, LC-LC Duplex SM (OS2) Fiber Patch Cord 3 Meter.

• 450' of 2" Rigid Conduit.

• 500’ of One (1) 48 Singlemode Fiber Bundle ran in conduit.

• Contractor Alarmed PDS shall have 24/7/365 monitoring of network cables detects tampering within the infrastructure.

• Contractor to supply Alarmed PDS that Eliminates daily inspections required of traditional PDS per Committee on National Security Systems Instruction (CNSSI) 7003.

• Contractor Alarmed PDS shall have Smart-filtering technology eliminates false alarms by learning normal day-to-day activity.

• Contractor Alarmed PDS shall have Plug-and-protect capability allows rapid deployment on new or existing network infrastructure.

• Contractor Alarmed PDS shall have Auto-configuration that eliminates time-consuming manual tuning.

• Contractor shall provide Alarmed PDS with no bandwidth bottlenecks or degradation of network performance.

• Contractor Alarmed PDS shall be able to Interface directly with the existing Vindicator

Five (5) Intrusion Detection System (IDS).

• Contractor shall provide installation.

• Contractor shall provide all Original Equipment Manufacturer (OEM) Manuals

• Contractor must meet all requirements outlined in the Statement of Work (SOW).