S02 Safety or Environmental Violations and Experience Modification Rate.pdf
PDF 82 KB Posted
- Solicitation number
- 36C24221B0014
About this file
This solicitation is for a construction project to replace condenser water piping at the Brooklyn VA Medical Center in Brooklyn, New York. The scope of work includes replacing condenser water piping from the chiller plant to the cooling towers on the roof of Building 4, replacing valves controlling flow in these lines, installing electrical heat tracing of the piping, and installing a centrifugal separator/cleaner package. Additional requirements include installing support piers for piping located on the roof. The period of performance is 260 days from notice to proceed. Bidders must provide safety and environmental violation histories, experience modification rates, payment and performance bonds within 10 days of award, and comply with various safety, security and coordination requirements during the project. The estimated award date is not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMENDMENT 2.pdf | ||
| 36C24221B0014 0002.docx | DOCX document | |
| RFI ANSWERS.pdf | ||
| 36C24221B0014 0001.docx | DOCX document | |
| S02 BID SHEET NEW.docx | DOCX document | |
| S02 ALL POSTERS.pdf | ||
| S02 Participation Goals for Minorities and Females.pdf | ||
| S02 SPECS.pdf | ||
| S02 VA ID PACKAGE 06-18-2019.pdf | ||
| 36C24221B0014_1.docx | DOCX document | |
| S02 DRAWINGS.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Safety or Environmental Violations and Experience Modification Rate
All Bidders/Offerors shall submit the following information pertaining to their past Safety and
Environmental record. The information shall contain, at a minimum, a certification that the bidder/offeror has no more than three (3) serious, or one (1) repeat or one (1) willful OSHA or any EPA violation(s) in the past three years.
All Bidders/Offerors shall submit information regarding their current Experience Modification
Rate (EMR) equal to or less than 1.0. This information will be obtained from the bidder’s/offeror’s insurance company and be furnished on the insurance carrier’s letterhead.
Self-insured contractors or other contractors that cannot provide their EMR rating on insurance letterhead shall obtain a rating from the National Council on Compensation Insurance, Inc.
(NCCI) by completing/submitting form ERM-6 and providing the rating on letterhead from
NCCI. Note: Self-insured contractors or other contractors that cannot provide EMR rating on insurance letterhead from the states or territories of CA, DE, MI, NJ, ND, OH, PA, WA, WY, and PR will obtain their EMR rating from their state-run worker’s compensation insurance rating bureau.
A Determination of Responsibility shall be accomplished for the apparent awardee prior to processing the award. The above information, along with other information obtained from
Government systems, such as the OSHA and EPA online inspection history databases, will be used to make the Determination of Responsibility. Failure to affirm being within the guidelines above or submit this information shall result in a determination of “Non-Responsibility” for the bidder/offeror. NOTE: Any information received by the Government that would cause an adverse Determination of Responsibility shall make the bidder/offeror ineligible for award.
This requirement is applicable to all subcontracting tiers, and prospective prime contractors are responsible for determining the responsibility of their prospective subcontractors.
File details come from the government source that posted it. Updated .