S02 - Ft Detrick CBOC Roof Replacement_DWG.pdf
PDF 10 MB Posted
- Solicitation number
- 36C24522B0007
About this file
This federal contract opportunity solicitation seeks a construction contractor to replace the roof at the Department of Veterans Affairs Medical Center in Fort Detrick, Maryland. The selected contractor will be responsible for removing the existing ballast, EPDM and roof insulation, installing new energy star roof insulation and thermoplastic polyolefin roofing material, and reinstalling the lighting protection, metal coping, gutters and downspouts. The rooftop air conditioning unit will also need to be removed and reinstalled as part of the project. The goal is to provide an upgraded roof to replace the existing leaking roof at the VA Medical Center located at 1433 Porter St. in Frederick, Maryland. The project number is 613-22-138. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 5.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAMC, MARTINSBURG WV
Approved:
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
GI 001
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Cover Sheet
PROJECT TITLE
PROJECT ADDRESS
REPLACE FT.DETRICK CBOC ROOF
PROJECT# 613-22-138
FT. DETRICK CBOC
1433 PORTER ST. FREDERICK,
MARYLAND 21702
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:54:44 PM vhamwvzeinec
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
GI 002
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Index of Drawings, Symbols & Abbreviations
Contractor shall furnish all labor, tools, material, equipment, supplies and supervision necessary for Roof replacement as shown in accordance with VA specifications and drawings.
1. Overview A. This project will engage a Contractor to remove existing Ballast, EPDM and roof
Insulation. Install Energy Star Roof Insulation and Thermoplastic Polyolefin (TPO) White in color sheet roofing, adhered or Mechanically Fastened to existing roof Decking.
B. Items of work to include but not limited:
1. Remove existing Ballast, EPDM, and Roof Insulation to existing metal decking.
2. Remove all Debris from site.
3. Replace existing insulation with an Energy Star Taper design by supplier to route all water to existing drains.
4. Remove and reinstall existing Lightening Protection.
5. Remove and reinstall existing Coping metal.
6. Remove and reinstall existing Gutters and Downspout as needed.
7. Install an Energy Star Thermoplastic Polyolefin (TPO) white in color sheet roofing.
8. Install walkway pads per "New Work" detail.
9. Roof top (AHU) Air Condition Unit (Per drawings and Spec) will need removed prior to demo; Existing unit will need to be installed at a later date. This portion of the project will need to be scheduled with the VA COR prior to commencing work.
1. ALL PROSPECTIVE BIDDERS SHOULD INSPECT THE WORK SITE
PRIOR TO THE BID OPENING TO TAKE AND VERIFY.
DIMENSIONS VERIFY SITE CONDITIONS, ASK QUESTIONS, ETC.
2. CALL ENGINEERING OFFICE AT 304-263-0811 EXT. 3381 TO
SCHEDULE SITE VISIT. ALL VISITS ARE TO BE ESCORTED DUE
TO SECURITY.
3. CONTRACTOR TO VERIFY ALL DIMENSIONS AND SQUARE
FOOTAGES PROVIDED.
PREBID & WORK SITE INSPECTION
KEY NOTE NUMERAL
ELEVATION MARK
DETAIL MARK
SHEET NO.
DETAIL NO.
WALL & PARTITION TYPE
WINDOW MARK
DOOR MARK
SPACE MARK
NUMERAL
NUMERAL(S)
DOOR NUMBER
XCOLUMN GRID
DATUM ELEVATION
SECTION MARK DETAIL NO.
SHEET NO.
LOCATION
X'-XX"
NUMERALREVISION MARK
XX
XX.XX
XX
XX.XX
XX.XX
XX
X###ROOM NAME
X
X
1. GC TO VERIFY BASE BUILDING AS BUILT CONDITIONS PRIOR TO PROCEEDING WITH WORK AND
IMMEDIATELY NOTIFY VAMC REPRESENTATIVE OF ANY CONDITIONS CONTRARY TO THOSE SHOWN
OR INFERRED ON THE DRAWINGS.
2. ALL DIMENSIONS THROUGHOUT DRAWINGS ARE IN ENGLISH (FPS) SYSTEM UNLESS OTHERWISE
NOTED.
3. ALL CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF CODES CURRENTLY ADOPTED BY THE GOVERNMENTAL AUTHORITY HAVING JURISDICTION. ANY CONDITIONS ON THE DRAWINGS KNOWN TO
BE NON-COMPLYING SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER.
4. ALL WORK SPECIFIED HEREIN SHALL BE INSPECTED IN ACCORDANCE WITH THE BUILDING CODES
CURRENTLY ADOPTED BY THE GOVERNMENTAL AUTHORITY HAVING JURISDICTION.
5. ALL WORK SHALL SPECIFIED HEREIN SHALL COMPLY WITH ALL APPLICABLE CODES AND
ORDINANCES.
6. ALL PARTS AND MATERIALS APPLICABLE SHALL BE SUPPLIED AND INSTALLED, PER MANUFACTURED
SYSTEM INSTALLATION REQUIREMENTS.
7. ALL COMPONENTS, EQUIPMENT, ETC., SHALL BE INSTALLED PER MANUFACTURER'S PRINTED
INSTRUCTIONS.
8. IF THE CONTRACTOR OBSERVES ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT/ENGINEER, REQUESTING CLARIFICATION.
IF THE CONTRACTOR PROCEEDS WITH WORK AFFECTED BY SUCH ERRORS, DISCREPANCIES OR
OMISSIONS WITHOUT RECEIVING SUCH CLARIFICATION, HE DOES SO AT HIS OWN RISK. ANY
ADJUSTMENTS INVOLVING SUCH CIRCUMSTANCES MADE BY THE CONTRACTOR, PRIOR TO
APPROVAL BY THE ARCHITECT/ENGINEER, SHALL BE AT THE CONTRACTOR'S RISK AND THE
SETTLEMENT OF ANY COMPLICATIONS OR DISPUTES ARISING THEREFROM SHALL BE AT THE
CONTRACTOR'S SOLE EXPENSE.
9. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONARY MEASURES TO PROTECT THE
PUBLIC AND ADJACENT PROPERTIES FROM DAMAGE THROUGHOUT CONSTRUCTION.
10. THE STARTING OF WORK BY CONTRACTOR OR SUBCONTRACTOR SHALL BE CONSIDERED
PROOF THAT HE HAS INSPECTED AND ACCEPTED ALL CONDITIONS INVOLVED IN HIS WORK AND
FINDS THEM SATISFACTORY.
11. ALL LUMBER, WOOD GROUNDS, NAILERS AND BLOCKING CONCEALED IN WALLS OR LOCATED IN
CEILING PLENUMS SHALL BE FIRE-RETARDANT TREATED.
12. EXTREME CARE SHALL BE EXERCISED IN CUTTING, DRILLING OR ANCHORING TO THE EXISTING
STRUCTURE. IF ANY DETERIORATION OR DAMAGE TO THE EXISTING STRUCTURE OCCURS OR IS
OBSERVED DURING DEMOLITION OPERATIONS, IT SHALL BE REPORTED TO THE CONTRACTING
OFFICER'S TECHNICAL REPRESENTATIVE.
THRESHOLD TYPE NUMERAL(S)
THE FOLLOWING IS THE MANDATORY INFECTION CONTROL/ CONSTRUCTION EVALUATION:
A. OBTAIN INFECTION CONTROL DOCUMENTS AND START WORK PERMIT BEFORE CONSTRUCTION BEGINS.
B. ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF DUCT
SYSTEM.
C. COMPLETE ALL TEMPORARY CONSTRUCTION FENCING BEFORE EACH PHASE OF CONSTRUCTION.
D. DO NOT REMOVE CONSTRUCTION FENCING FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY VAMC COR.
LOCATION MAP DRAWING INDEXVICINITY MAPCODE ANALYSIS
SCOPE OF TENANT WORK:
PURPOSE OF SPACE:
NUMBER OF STORIES IN BUILDING:
TYPE OF CONSTRUCTION:
HIGH RISE BUILDING:
AREA PER FLOOR:
MAXIMUM OCCUPANCY:
SPRINKLERS:
FIRE RESISTANCE DESIGN:
N/A N/A N/A N/A
APPLICABLE CODES
BUILDING CODE: N/A
MECHANICAL CODE: N/A
PLUMBING CODE: N/A
ELECTRICAL CODE: N/A
LIFE-SAFETY: N/A
ACCESSIBILITY CODE: N/A
1. THE VA MEDICAL CENTER IS AN OSHA INSPECTED WORK SITE AND CONTRACTORS ARE SUBJECTED TO
FOLLOW ALL VA AND OSHA SAFETY RULES, REGULATIONS AND STANDARDS.
2. CONTRACTOR IS REQUIRED TO PROVIDE FALL PROTECTION FOR HIS EMPLOYEES. A FALL PROTECTION PLAN
SHOULD BE ESTABLISHED AND SUBMITTED TO THE VA.
3. THE CONTRACTOR IS TO PROTECT PATIENTS, VISITORS AND EMPLOYEES FROM FALLING DEBRIS FOR THE
DURATION OF THIS PROJECT.
CONTRACTOR'S EMPLOYEES SHALL NOT ENTER THE PROJECT SITE WITHOUT APPROPRIATE VA MEDICAL CENTER SITE ACCESS BADGE. CONTRACTOR'S MUST OBTAIN ID BADGES IN ACCORDANCE WITH MEDICAL CENTER MEMORANDUM (MCM) 05-04 "PERSONNEL SUITABILITY AND SECURITY PROCEDURES. CONTRACTOR PERSONNEL MAY ALSO BE SUBJECT TO INSPECTION OF THEIR PERSONAL EFFECTS WHEN ENTERING OR LEAVING THE
PROJECT SITE.
SAFETY REQUIREMENTS
SECURITY REQUIREMENTS
SYMBOLS LEGEND
MANDATORY 'ICRA' REQUIREMENTS
MATERIALS LEGENDABBREVIATIONS GENERAL NOTES
A
ACT ACOUSTICAL CEILING TILE
ADO AUTOMATIC DOOR OPENER
AFF ABOVE FINISH FLOOR
ALT ALTERNATE OR ALTERNATIVE
ALUM ALUMINUM
ANOD ANODIZED
AV AUDIO VISUAL
B
BD BOARD
BLDG BUILDING
BLKG BLOCK OR BLOCKING
C
CB CEMENTITIOUS BOARD
CL CLEAR
CLG CEILING
CM CENTIMETER
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
COTR CONTRACTING OFFICER'S
TECHNICAL REPRESENTATIVE
CPT CARPET
CR CARD READER
CT CERAMIC TILE
D
DEG DEGREE
DEMO DEMOLITION
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DW DISHWASHER
DWG DRAWING
E
E EAST
EA EACH
EL ELEVATION (GRADE)
ELEC ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EXIST EXISTING
EXT EXTERIOR
F
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FIN FINISH
FLR FLOOR
FLUOR FLUORESCENT
FP FIREPROOFING
FR FIRE RETARDANT/FIRE RESISTIVE
FT FLOOR TRANSITION
FURN FURNITURE
FWC FABRIC WALL COVERING
G
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRF GLASS FIBER REINFORCED GYPSUM
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
HC HOLLOW CORE
HD HOLD
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION &
AIR CONDITIONING
I
ID INSIDE DIAMETER
IN INCH
INCAN INCANDESCENT
INSUL INSULATION
INT INTERIOR
J
JB JUNCTION BOX
JT JOINT
L
LAM LAMINATED
LAV LAVATORY
M
M METER
MAS MASONRY
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MANUF MANUFACTURER
MIN MINIMUM
MM MILLIMETER
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O
OC ON CENTER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OD OUTSIDE DIAMETER
OH OPPOSITE HAND OR OVERHEAD
OPER OPERABLE
OPP OPPOSITE
OPT OPTION OR OPTIONAL
P
P PAINT
PART PARTITION
PLAM PLASTIC LAMINATE
PR PAIR
PS PROJECTION SCREEN
PT PARTITION TYPE
PTD PAINTED
PVC POLYVINYL CHLORIDE
PWD PLYWOOD
Q
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
R
R RADIUS OR RISER
RCP REFLECTED CEILING PLAN
REINF REINFORCEMENT
REQ REQUIRED
RES RESILIENT
RM ROOM
RO ROUGH OPENING
RSF RENTABLE SQUARE FOOTAGE
S
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SC SOLID CORE OR SHOWER
CURTAIN
SCHED SCHEDULE OR SCHEDULED
SCW SOLID CORE WOOD
SECT SECTION
SF SQUARE FOOT OR SQUARE FEET
SH SPRINKLER HEAD
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SP STANDPIPE
SPEC SPECIFIED OR SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STN STONE
STND STAINED
STL STEEL
STOR STORAGE
STRU STRUCTURE OR STRUCTURAL
SUSP SUSPENDED OR SUSPENSION
SYM SYMBOL
SYS SYSTEM
T
TEL TELEPHONE
TERR TERRAZZO
T&G TONGUE & GROOVE
THK THICK OR THICKNESS
THRU THROUGH
TV TELEVISION
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
USF USABLE SQUARE FOOTAGE
UWS UPHOLSTERED WALL SYSTEM
V
VCT VINYL COMPOSITION TILE
V.C. VA PURCHASED CONTRACTOR
INSTALLED
VERT VERTICAL
VT VINYL TILE
VWC VINYL WALL COVERING
W
W WEST OR WIDE OR WIDTH
W/ WITH
WB WALL BASE
WC WATER CLOSET
WD WOOD
WDO WINDOW
WO WINDOW OPENING
W/O WITHOUT
WP WATERPROOFING
WR WASTE RECEPTACLE
WS WEATHERSTRIPPING
WSF WELDED SEAMLESS FLOORING
WSB WELDED SEAMLESS BASE
WT WEIGHT
Y
YD YARD
USE GROUP OF BUILDING:
FIRE ALARM SYSTEM:
DETAIL NO.
SHEET NO.
X
X
BLOCKING
CONTINUOUS WOOD
(LARGE SCALE)(LARGE SCALE)
STEEL STUD WALL
(LARGE SCALE)
RIGID INSULATION GLASS
STEEL
FACE BRICK
ALUMINUM
BLOCKING OR SHIMS
RESILIENT MATERIAL
ACOUSTICAL TILE CARPET (DOTTED LINE
ONLY WHEN OVER PAD)
(SMALL SCALE)
ACOUSTICAL/BATT RESILIENT MATERIAL
(LARGE SCALE)
CERAMIC TILE INTERMITTENT WOOD
INSULATION (SMALL SCALE)
FINISH WOOD
CERAMIC TILE
(LARGE SCALE)
PLYWOODGYPSUM BOARD
STRUCTURAL CONC.
CONC. BLOCK
General
1. GI 001
2. GI 002
3. GI 003
Architectural
4. AD 101
5. AE 101
6. AE 301
7. AE 501
8. AE 502
Electrical
9. AE 503
Cover Sheet Index of Drawings, Symbols & Abbreviations Work Location
Demolition - Plan View Roof (Existing Conditions) New Work/Construction - Plan View Roof Elevations - Exterior Scupper Locations Section Details - Exterior Section Details TPO Details - Exterior TPO lap Details
Electrical Details - Roof Exterior Electrical Details
SCOPE OF WORK
N/A N/A
N/A N/A N/A N/A N/A
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:56:51 PM vhamwvzeinec
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
GI 003
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Phasing & Limits of Work - Saftey Net & Material Laydown Location
Phasing & Limits of Work, Saftey Net & Material Laydown Location1
SAFETY
SCALE: 1/16" = 1' - 0" (SEE NOTES)
PREBID & WORK SITE INSPECTION
- EXISTING METAL ROOF
(NOT IN SCOPE OF WORK)
- NEW TPO ROOF AREA IN
HATCHING
- MATERIAL LAY DOWN AREA
- CONSTRUCTION FENCE
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:57:28 PM vhamwvzeinec
KEYNOTES
1. AREA OF NEW ROOF.
2. CONSTRUCTION SAFETY FENCE AT PERIMETER AS
NEEDED. KEEP FENCE AS CLOSE TO PEDESTRIAN
BREEZEWAY AS POSSIBLE.
3. CONSTRUCTION SAFETY FENCE.
4. PROVIDE SECURITY FENCE AS NEEDED FOR MATERIAL
STORAGE & LAYDOWN AREA.
GENERAL NOTES
KEY NOTES =
LEGEND
X
M
AT
ER
IA
L
LA
YD
O
W N
A R
EA
ADJOINING
BUILDING
(NO NEW WORK)
VAMC CBOC BUILDING
1434 BUILDING
(EXISTING METAL ROOF)
(EXISTING METAL ROOF)
EXISTING
EPDM ROOF
SYSTEM
EXISTING
EPDM ROOF
SYSTEM
PHASE 1
PHASE 2
PHASE 2
PHASE 3
PHASE 4 PHASE 4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AD 101
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Demolition - Roof
Demolition - Plan View Roof1 SCALE: 1/16" = 1' - 0"
1. REMOVE LIGHTING PROTECTION & REINSTALL LATER
TYP. SEE DETAIL 5
AE503 .
2. REMOVE COPING & REINSTALL LATER TYP.
3. REMOVE GUTTER & REINSTALL LATER TYP.
4. REMOVE BALLAST, EPDM & ROOF INSULATION TO
METAL DECKING TYP.
5. REMOVE EXISTING A.H.U. AND REINSTALL AT A LATER
DATE (SEE GENERAL NOTE 1)
6. EVALUATE ALL ROOF DRAINS TYP.CONTRACTOR TO
ENSURE ALL ROOF DRAINS ARE NOT DAMAGED ATER
DEMOLITION.
7. EXISTING EXPANSION JOINT - SALVAGE AND REUSE IF
ACCEPTABLE BY NEW ROOFING MANUFACTURER, IF NOT
- PROVIDE NEW SEE DETAIL 7A
AE501 .
8. REMOVE/REUSE PER MANUFACTURERS SPECIFICATION
SEE DETAIL 6
AE501 .
9. REMOVE SPLASH BLOCKS & REINSTALL LATER TYP.
10.REMOVE EXISTING EPDM FLASHING OVER SCUPPERS TO
PREPARE FOR NEW TPO FLASHING TYP.
11.REMOVE EXHAUST FANS EF-1&2 & REINSTALL LATER
SEE DETAIL 4
AE501 .
12.REMOVE EXHAUST FANS EF-3&4 & REINSTALL LATER SEE
DETAIL 4
AE501 .
13.REMOVE BOOTS AROUND ROOF VENTS TYP. SEE DETAIL
3A
AE501 AND 3B
AE501.
14.REMOVE BOOTS AROUND RADON EXHAUST DUCT.
15.ALL EXISTING METAL ROOF NOT IN SCOPE OF WORK TYP.
16.EXISTING EXPANSION JOINT SALVAGE AND REUSE IF
ACCEPTABLE BY NEW ROOFING MANUFACTURER, IF NOT
PROVIDE NEW SEE DETAIL 7B
AE501 .
GENERAL NOTES
KEY NOTES =
LEGEND
- LIGHTING PROTECTION
- SCUPPER LOCATION
- SPASH BLOCK
- EXHAUST FANS
- AIR HANDLING UNIT
- RADON EXHAUST DUCT (1)
- ROOF VENTS (4)
- ROOF DRAINS
- EXISTING METAL ROOF
(NOT IN SCOPE OF WORK)
X
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:58:17 PM vhamwvzeinec
1. ROOF TOP (AHU) AIR CONDITION UNIT (PER
DRAWINGS AND SPEC) WILL NEED REMOVED PRIOR
TO DEMO; EXISTING UNIT WILL NEED TO BE
INSTALLED AT A LATER DATE. THIS PORTION OF THE
PROJECT WILL NEED TO BE SCHEDULED WITH THE
VA COR PRIOR TO COMMENCING WORK.
EP
D
M R
O O
F
SY
ST
EM
EXISTING
EPDM ROOF
SYSTEM
EX
IS
TI
N
G
EP
D M
R O
O F
SY
ST
EM
EX
IS
TI
N
G
EP
D M
R O
O F
SY
ST
EM
EXISTING
EPDM ROOF
SYSTEM
EX
IS
TI
N
G
EP
D M
R O
O F
SY
ST
EM
EXISTING METAL ROOF
ADJOINING
BUILDING
EXISTING METAL ROOF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AE 101
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
New Work/Construction - Roof
New Work/Construction - Plan View Roof1 SCALE: 3/32" = 1' - 0"
KEYNOTES
1. REINSTALL LIGHTING PROTECTION TYP. SEE DETAIL 5
AE503.
2. REINSTALL COPING TYP.
3. REINSTALL GUTTER TYP.
4. INSTALL TPO & ROOF INSULATION TO METAL DECKING
TYP. & FOR CRICKETS INSTALL ROOFING MATERIALS PER
DRAINAGE TO EXISTING DRAINS PER MANUFACTURERS
SPECIFICATIONS. SEE SHEET AE502
FOR TPO LAP DETAILS.
5. REINSTALL AIR HANDLING UNIT AS FOLLOWS: (SEE
GENERAL NOTES)
6. INSTALL NEW ROOFING, INSULATION & FLASHING AROUND
EXISTING DRAINS PER MANUFACTURERES
SPECIFICATIONS TYP.
7. REWORK EXPANSION JOINT AS NEEDED PER NEW ROOF
SEE DETAIL 7A
AE501 .
8. REINSTALL RJT TO SF TRANSITION PER MANUFACTURERS
SPECIFICATION SEE DETAIL 6
AE501 .
9. REINSTALL SPLASH BLOCKS AS NEEDED. HEAT WELD A
LAYER OF TPO TO NEWLY INSTALLED ROOF TPO WITH 3"
ADDITIONAL TPO AROUND ENTIRE PERIMETER OF EACH
SPLASH BLOCK.
10.REFLASH EXISTING SCUPPERS PER MANUFACTURERS
RECOMMENDATIONS TYP. SEE DETAIL 2
AE501 .
11.REINSTALL EXHAUST FANS EF-1&2 SEE DETAIL 4
AE501 .
12.REINSTALL EXHAUST FANS EF-3&4 SEE DETAIL 4
AE501 .
13.REINSTALL NEW BOOTS AROUND ROOF VENTS TYP. SEE
DETAIL 3A
AE501 AND 3B
AE501 .
14.REINSTALL NEW BOOTS AROUND AROUND RADON
EXHAUST DUCT.
15.24"X24" WALKWAY PADS TO BE INSTALLED AROUND
EQUIPMENT & EXHAUST FANS AS PREVIOUSLY INSTALLED.
16.REWORK EXPANSION JOINT AS NEEDED PER NEW ROOF
SEE DETAIL 7B
AE501 .
GENERAL NOTES
KEY NOTES =
LEGEND
- LIGHTING PROTECTION
- SCUPPER LOCATION
- SPASH BLOCKW/HEAT WELDED TPO BENEATH
- EXHAUST FANS
- AIR HANDLING UNIT
- RADON EXHAUST DUCT (1)
- ROOF VENTS (4)
- ROOF DRAINS
- WALKWAY PADS
X or
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:59:03 PM vhamwvzeinec
1. ROOF TOP (AHU) AIR CONDITION UNIT (PER
DRAWINGS AND SPEC) WILL NEED REMOVED PRIOR
TO DEMO; EXISTING UNIT WILL NEED TO BE
INSTALLED AT A LATER DATE. THIS PORTION OF THE
PROJECT WILL NEED TO BE SCHEDULED WITH THE VA
COR PRIOR TO COMMENCING WORK.
2. AHU DURING THE INSTALL SHOULD BE
MOUNTED ON EXISTING ROOF PAVERS WITH
ADDITION TPO SLIP WELDED IN PLACE
UNDERNEATH THE PAVERS.
3. A PENETRATION POCKET FOR THE AHU LINE
SETS TO BE INSTALLED DURING NEW WORK.
4. CONTRACTOR TO HAVE A STANDBY AHU TO
CONDITION THE COMMUNICATION ROOM
PRIOR TO PROCEEDING WITH REMOVING THE
ROOF TOP AHU.
5. COMMUNICATION ROOM #134 LOCATED IN
THE MECHANICAL ROOM #133.
EXISTING METAL ROOF
N
EW
T
PO
R O
O
FI
N G
W /3
YE
AR
W
AR
R
AN
TY
N
EW
T
PO
R O
O
FI
N G
W /3
YE
AR
W
AR
R
AN
TY
N
EW
T
PO
R O
O
FI
N G
W /3
YE
AR
W
AR
R
AN
TY
NEW TPO ROOFING
W/30 YEAR WARRANTY
NEW TPO ROOFING
W/30 YEAR WARRANTY
N
EW
T
PO
R O
O
FI
N G
W /3
YE
AR
W
AR
R
AN
TY
ADJOINING
BUILDING
AE105
AE501
AE501
SIM
AE501
AE501
AE501
SIM
AE501
AE501
SIM
AE501
SIM
AE501
AE501
AE501
AE501
AE501
SIM
AE501 1
AE501
AE501
AE501
SIM
EXISTING METAL ROOF
SIM
SIM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AE 301
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Elevations - Scupper Locations
South Elevation - Overflow Scupper Locations1 SCALE: 3/32" = 1' - 0"
North Elevation - Overflow Scupper Locations2 SCALE: 3/32" = 1' - 0"
East Elevation - Overflow Scupper Locations3 SCALE: 3/32" = 1' - 0"
West Elevation - Overflow Scupper Locations4 SCALE: 3/32" = 1' - 0"
KEYNOTES
1. 4X8 OVERFLOW SCUPPER. TO BE INSTALLED PER
MANUFACTURERS SPECIFICATIONS SEE DETAIL 2
AE501 .
CONTRACTOR TO VERIFY LOCATIONS AND QUANTITIES
OF SCUPPERS PRIOR TO BID.
GENERAL NOTES
KEY NOTES =
LEGEND
- SCUPPER LOCATION
X
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 12:59:38 PM vhamwvzeinec
FIRST FLOOR
0' - 0"
FIRST FLOOR
0' - 0"
T.O. HIGH
DECKING
14' - 10"
T.O. HIGH
DECKING
14' - 10"
TOP OF STEEL @
CANOPY
18' - 8"
T.O. MASONRY @
HIGH PARAPET
16' - 8"
T.O. MASONRY @
HIGH PARAPET
16' - 8"
FIRST FLOOR
0' - 0"
FIRST FLOOR
0' - 0"
T.O. HIGH
DECKING
14' - 10"
T.O. HIGH
DECKING
14' - 10"
TOP OF STEEL @
CANOPY
18' - 8"
T.O. MASONRY @
HIGH PARAPET
16' - 8" T.O. MASONRY @
HIGH PARAPET
16' - 8"
T.O. MASONRY
FIRST FLOOR
0' - 0"
FIRST FLOOR
0' - 0"
T.O. HIGH
DECKING
14' - 10"
TOP OF STEEL @
CANOPY
18' - 8"
T.O. MASONRY @
HIGH PARAPET
16' - 8"
T.O. MASONRY @
LOW PARAPET
15' - 4"
T.O. LOW DECKING
13' - 6"
T.O. MASONRY
10' - 0"
T.O. MASONRY @
LOW PARAPET
FIRST FLOOR
0' - 0"
T.O. HIGH
DECKING
14' - 10"
TOP OF STEEL @
CANOPY
18' - 8"
T.O. MASONRY @
HIGH PARAPET
16' - 8"
T.O. FOOTING
-2' - 0"
15' - 4"
T.O. LOW DECKING
13' - 6"
T.O. MASONRY
10' - 0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AE 501
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Exterior Section/Details - Roof
Section Detail 1 SCALE: NONE
Overflow Thru Wall Scupper (Welded Sleeve) Detail Typ.2 SCALE: NONE
Vent Penetration with TPO Large Pipe Flashing - Detail Typ.3A SCALE: NONE Roof Mounted Exhaust Fans - Detail Typ.4 SCALE: NONE
RJT to SF Transition at Parapet6 SCALE: NONE
Existing Expansion Joint (Field Fabricated) with Welded Splice - Roof to Roof7A SCALE: NONE
Section Detail 8 SCALE: NONE Section Detail 9 SCALE: NONE
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 1:00:25 PM vhamwvzeinec
3B SCALE: NONE
Vent Penetration with TPO Small Pipe Flashing - Detail Typ.
Existing Expansion Joint (Field Fabricated) with Welded Splice - Roof to Wall7B SCALE: NONE
1'-0"
NOTES:
1. APPROVED PRIMER REQUIRED ON ALL VERTICAL SURFACES.
2. APPROVED BONDING ADHESIVE REQUIRED BETWEEN QUICKSEAM
RPF STRIP AND SUBSTRATE (INSULATION OR WALL).
3. WHEN REINFORCEMENT OF TPO MEMBRANE IS EXPOSED, REFER TO
MANUFACTURERES RECOMMENDED EDGE SEALANT APPLICATION
WALL / CURB
FASTENER PER MANUFACTURERERS RECOMMENDATION.
QUICKSEAM RPF STRIP MUST EXTEND
1/2" (13 mm) BEYOND HD OR HD PLUS SEAM PLATE
PO
SI
TI
ON
P
LA
TE
1/
2" (1
3 m m)
MI
N.
A
BO
VE
F
IN
IS
HE
D
RO
OF
TPO QUICKSEAM RPF STRIP
WITH 3" (76 MM) TAPE
BONDING ADHESIVE (SEE NOTE #2)
1 2"
APPROVED PRIMER (SEE NOTE #1)
TPO MEMBRANE
ROOF DECK ON
METAL JOISTS
SLOPE DN 1/4" : 12"
INSULATION
USE APPROPRIATE TERMINATIONCOPING
WALL
WALL
TPO MEMBRANE
SINGLE PLY LVOC PRIMER
SINGLE PLY LVOC PRIMER
CONTINUOUS BEAD OF TPO SEALANT (TYP.)
RECOMMENDED BY MANUFACTURER
5.5" TPO FLASHING CENTERED OVER
EDGE OF SCUPPER FLANGE
CONTINUOUS BEAD OF
WATER BLOCK
APPROPRIATE FASTENER
4" (102mm) O.C. MAX
EXISTING WELDED METAL
SCUPPER SLEEVE (SEE NOTE #2)
5.5" TPO FLASHING CENTERED OVER EDGE OF
SCUPPER SLEEVE
CONTINUOUS BEAD OF TPO
BONDING SEALANT OR HIGH
GRADE URETHANE SEALANT
PER MANUFACTURERS
RECOMMENDATIONS
9.5" TPO FLASHING CENTERED OVER 5.5"
TPO FLASHING AT BASE OF SCUPPER ONLY
APPROVED PRIMER REQUIRED
ON ALL VERTICAL SURFACES
CONTINUOUS BEAD OF WATER BLOCK
TPO MEMBRANE
USE APPROPRIATE TERMINATION COPING
SLOPE DN 1/4" : 12"
INSULATION
INSULATION
SUBSTRATE
INSULATION
SUBSTRATE
RO
UN
D
PE
NE
TR
AT
IO
N
WELDED SPLICE
2" (51 mm) MIN.
FIELD SEAM
NOTE:
1. REMOVE ALL EXISTING FLASHING, ETC.
PIPE SURFACE MUST BE FREE OF ALL RUST,
GREASE, INSULATION, ETC.
2. PIPE MUST BE ANCHORED TO ENSURE STABILITY.
3. PRE-MOLDED PIPE FLASHING MAY BE CUT TO
HEIGHT, BUT NO LOWER THAN REINFORCING RING
(NO WRINKLES OR FOLDS UNDER CLAMPING RING).
4. APPLY APPROVED MANUFACTURES SEALANT
BETWEEN PENETRATION AND PRE-MOLDED PIPE
FLASHING PRIOR TO INSTALLATION OF CLAMPING
RING.
5. LARGE PRE-MOLDED PIPE FLASHING FITS
4" (102 mm) - 8" (203 mm) PENETRATIONS SIZES.
6. DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS
160 °F (71 °C). REFER TO UT- P-6 & UT-P-7.
CONTINUOUS BEAD
OF ULTRAPLY TPO
APPROVED SEALANT
STAINLESS STEEL
CLAMPING RING
(SEE NOTE #4)
CONTINUOUS BEAD OF
APPROVED SEALANT OR
HIGH GRADE SEALANT
FIELD FABRICATED
METAL HOOD BY
OTHERS (OPTIONAL)
PRE-MOLDED TPO
PIPE FLASHING
TPO T-JOINT COVER
OR TPO FLASHING
(4" (102 mm) x 4" (102mm) MIN.)
CENTERED OVER INTERSECTION.
PLAN VIEW
PIPE FLASHING
OVER SEAM
TPO MEMBRANE
WELDED SPLICE
2" (51 mm) MIN.
ROOF
EXHAUST FAN
FACTORY INSTALLED
CONDUIT CHASE & MANUAL
DISCONNECT.
12-IN ROOF CURB
LAG BOLT PRV TO CURB ON
FOUR SIDES WITH
NONRUSTING FASTENERS,
NO NAILS. LAG - 12" O.C.
FOAM RUBBER GASKET
APPLIED TO UNDERSIDE OF
FAN CURB CAP.
INSULATION
SUBSTRATE
COMPRESSIBLE TUBE
SUBSTRATE
INSULATION
NOTE:
1. COMPRESSIBLE TUBE DIAMETER MUST EXCEED THE
DECK OPENING BY 50% MIN. OR DESIGNATED MOVEMENT
(WHICH EVER IS GREATER)
4. WHEN REINFORCEMENT OF TPO MEMBRANE IS EXPOSED,
CUT EDGE SEALANT APPLICATION PER MAUNFACTURES
RECOMMENDATION TYP.
6. REFER TO TPO-SA-LS-1 FOR ADDITIONAL LAP SPLICE
REQUIREMENTS.
STANDARD
TPO MEMBRANE
COMPRESSIBLE INSULATION WITH INSULATION
RETAINER AND FASTENER AS REQUIRED
METAL SEAM PLATES AND FASTENER
PER MANUFACTURES RECOMENDATION
TPO MEMBRANE
T.O. HIGH
DECKING
14' - 10"
SHTMET-3 FLASHING
SALVAGED SIMPSON
CLIP ANGLE @ 2'-0" O.C. SIMPSON CLIP
ANGLE @ 2'-0" O.C.
SALVAGED 6" GUTTER WITH
DOWNSPOUT AND SPLASH BLOCK.
SLOPE DN 1/4" : 12"
TPO MEMBRANE ON FULLY
ADHERED TPO BASE FLASHING
TYPICAL FLAT ROOF CONSTRUCTION
LOOSE LAID BALLASTED EPDM ROOF
SYSTEM WITH TAPERED R-30 INSULATION
AND PROTECTION BOARD. PROVIDE 3" MIN.
INSULATION @ DRAINS.
EXISTING
CONSTRUCTION
TO REMAIN SHOWN
SHADED TYP
INSULATION
SUBSTRATE
RO
UN
D
PE
NE
TR
AT
IO
N
SUBSTRATE
TPO MEMBRANE
FIELD SEAM
WELDED SPLICE
2" (51 mm) MIN.
NOTE:
1. REMOVE ALL EXISTING FLASHING, ETC.
PIPE SURFACE MUST BE FREE OF ALL RUST,
GREASE, INSULATION, ETC.
2. PIPE MUST BE ANCHORED TO ENSURE STABILITY.
3. PRE-MOLDED PIPE FLASHING MAY BE CUT TO
HEIGHT, BUT NO LOWER THAN REINFORCING RING
(NO WRINKLES OR FOLDS UNDER CLAMPING RING).
4. APPLY APPROVED MANUFACTURES SEALANT
BETWEEN PENETRATION AND PRE-MOLDED PIPE
FLASHING PRIOR TO INSTALLATION OF CLAMPING
RING FOR SEAM EDGE TREATMENT TYP.
5. SMALL PRE-MOLDED PIPE FLASHING FITS
1" (25 mm) - 3-1/2" (89 mm) PENETRATION SIZES.
6. DO NOT USE WHEN SERVICE LINE TEMP
EXCEEDS 160 °F (71 °C).
7. CONTACT FIRESTONE TECHNICAL DEPARTMENT FOR
ALTERNATIVE PENETRATION DETAILS.
CONTINUOUS BEAD
OF ULTRAPLY TPO
APPROVED SEALANT
STAINLESS STEEL
CLAMPING RING
(SEE NOTE #4)
CONTINUOUS BEAD OF
APPROVED SEALANT OR
HIGH GRADE SEALANT
FIELD FABRICATED
METAL HOOD
PRE-MOLDED TPO
PIPE FLASHING
TPO T-JOINT COVER
OR TPO FLASHING
(4" (102 mm) x 4" (102mm) MIN.)
CENTERED OVER INTERSECTION
PLAN VIEW
PIPE FLASHING
OVER SEAM
INSULATIONINSULATION
WALL / CURB
INSULATION
SUBSTRATE
STANDARD TPO MEMBRANE
COMPRESSIBLE TUBE
USE APPROPRIATE
TERMINATION
APPROPRIATE FASTENER
WELDED SPLICE
(SEE NOTE #2)
NOTES:
1. COMPRESSIBLE TUBE DIAMETER MUST
EXCEED THE DECK OPENING BY 50%
MIN. OR DESIGNATED MOVEMENT
(WHICH EVER IS GREATER)
2. WHEN REINFORCEMENT OF TPO
MEMBRANE IS EXPOSED EDGE
SEALANT APPLICATION TYP.
3. APPROVED PRIMER REQUIRED ON ALL
VERTICAL SURFACES.
ULTRAPLY TPO SA FOR FLEX SA
MEMBRANE
COMPRESSIBLE INSULATION WITH
INSULATION RETAINER
METAL SEAM PLATE AND FASTENERS
PER MANUFACTURES RECOMMENDATION
APPROPRIATE PRIMER
9 1/2"
NOTES:
1. APPROVED PRIMER REQUIRED ON ALL VERTICAL SURFACES.
2. APPROVED BONDING ADHESIVE REQUIRED BETWEEN QUICKSEAM
RPF STRIP AND SUBSTRATE (INSULATION OR WALL).
3. WHEN REINFORCEMENT OF TPO MEMBRANE IS EXPOSED, REFER TO
MANUFACTURERES RECOMMENDED EDGE SEALANT APPLICATION
WALL / CURB
FASTENER PER MANUFACTURERERS RECOMMENDATION.
QUICKSEAM RPF STRIP MUST EXTEND
1/2" (13 mm) BEYOND HD OR HD PLUS SEAM PLATE
PO
SI
TI
ON
P
LA
TE
1/
2" (1
3 m m)
MI
N.
A
BO
VE
F
IN
IS
HE
D
RO
OF
TPO QUICKSEAM RPF STRIP
WITH 3" (76 MM) TAPE
BONDING ADHESIVE (SEE NOTE #2)
1 2"
APPROVED PRIMER (SEE NOTE #1)
TPO MEMBRANE
SLOPE DN 1/4" : 12"
INSULATION
USE APPROPRIATE TERMINATION COPING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text J
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AE 502
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Exterior TPO Lap Details - Roof
Lap Splice with Continupus Weld1 SCALE: NONE
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 1:01:19 PM vhamwvzeinec
TPO End Lap Splice with Welded TPO Cover Strip2 SCALE: NONE Outside Corner3 SCALE: NONE
Inside Corner4 SCALE: NONE Lap Splice with Lap Under Field Seam using T-Joint Cover5 SCALE: NONE
Roof Edge with Fascia Metal 6 SCALE: NONE
SLOPE
SLOPETPO MEMBRANE
TPO MEMBRANE
NOTE:
1. SEAMS MAY RUN PARALLEL WITH WATER FLOW
2" (51 mm) MIN. HAND WELD
1 1/2" (38 mm) MIN. AUTOMATIC WELDER
4" (102 mm) 4" (102 mm)
TPO MEMBRANE
8" (204 mm) COVER STRIP TPO MEMBRANE
NOTE:
1. IF THE TOP OF MEMBRANE IS CONTAMINATED BY ADHESIVE
OR ASPHALT ON EITHER SIDE OF THE END SPLICE, CLEAN
THOROUGHLY PRIOR TO WELDING.
2" (51 mm) MIN. - HAND WELD 1" (38 mm) MIN. - ROBOT WELD
2" (51 mm) MIN. - HAND WELD 1" (38 mm) MIN. - ROBOT WELD
6" (152 mm) MIN.
USE APPROPRIATE
TERMINATION
USE APPROPRIATE
BASE TIE-IN
TPO MEMBRANE (FIELD SHEET)
NOTE:
1. WHEN REINFORCEMENT OF TPO MEMBRANE IS
EXPOSED EDGE SEALANT APPLICATION - REFER
TO MANUFACTURERS RECOMMENDATION TYP.
TPO 18" CURB FLASHING OR MEMBRANE
HEAT WELDED TO TPO FIELD SHEET
PRE-MOLDED TPO INSIDE/OUTSIDE
CORNER WELDED IN
TPO MEMBRANE
NOTE:
1. IF INSIDE CORNER IS FIELD FABRICATED
USE AN ADDITIONAL PIECE OF
UNSUPPORTED FLASHING TO COVER
FOLD.
PRE-MOLDED TPO
INSIDE/OUTSIDE CORNER
WELDED IN PLACE
WELD VERTICAL SEAM
NOTE:
1. TPO FLASHING (UNSUPPORTED) (4" x 4" MIN. WITH
ROUNDED CORNERS) MAY BE USED IN LIEU OF
T-JOINT COVER.
2. WHEN REINFORCEMENT OF TPO MEMBRANE IS
EXPOSED EDGE SEALANT APPLICATION -
MANUFATURES RECOMMENDATION TYP.
TPO MEMBRANE
TPO MEMBRANE
TPO MEMBRANE
TPO T-JOINT COVER, CENTER
OVER HEADLAP
WELDED SPLICE AT
HEADLAP
WELDED FIELD SPLICE AT
FIELD SEAM
INSULATION
SUBSTRATE
WALL
TPO MEMBRANE
ACCEPTABLE PRIMER
NOTE:
1. INSTALL METALWORK TO
MANUFACTURES REQUIREMENTS
OR SMACNA RECOMMENDATIONS.
IF SHOP FABRICATED METAL EDGE
IS USED IT MUST MEET ANSI/SPRI
ES-1 OR AN FM STANDARD.
2. TPO SEALANT IS REQUIRED ALONG
ENTIRE UPSLOPE EDGE OF
FLASHING WHEN ROOF.
3. WOOD NAILER MUST BE INSTALLED
TO MEET APPLICABLE BUILDING
CODES AS NEEDED.
4. TPO FLASHING MUST EXTEND TO
WITHIN 1/4" (6 mm) OF THE FLANGE
EDGE.
EXISTING FACIA METAL
REUSE DURING NEW WORK
CLEAT
METAL (SEE NOTE #1)
ACCEPTABLE MEMBRANE
ADHESIVE
TPO FLASHING
TPO FLASHING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
\\r04mwvnas21\FMS Projects\Current Projects\613-22-138 Replace Fort Detrick Roof\1.0 DESIGN\IN-HOUSE Design\CAD Drawings\Replace Ft.Detrick Roof.dwg 05/05/2022 1:02:12 PM vhamwvzeinec
Approved:
Approved:
Drawing Title
Location
Building Number
Project Title
Checked Drawn
Project No.
Date
DateCAD
Drawing Number
Explanation & InitialsRev
AE 503
Replace Ft.Detrick CBOC Roof
CJZ
03/22/2022
613-22-138
613-22-138
Office of Construction and Facilities Management
Electrical Details - Roof
ROOF DRAIN BOND DETAIL1 SCALE: NONE
LIGHTNING PROTECTION SYSTEM2 ROOF DRAIN/VENT PIPE BOND DETAIL
SCALE: NONE
VENT PIPE THRU ROOF BOND DETAIL
AIR TERMINAL & FLAT SURFACE MOUNTING3 BASE ASSEMBLED
SCALE: NONE
SLOPED ROOF AIR TERMINAL4 SCALE: NONE
AIR TERMINAL5 SCALE: NONE
MECHANICAL EQUIPMENT CONNECT AT ROOF6 SCALE: NONE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
GROUNDING TERMINAL
AutoCAD SHX Text
LOOP
AutoCAD SHX Text
ROOF CIRCUIT
AutoCAD SHX Text
CONNECT TO
AutoCAD SHX Text
TO ROOF CIRCUIT LOOP
AutoCAD SHX Text
CONDUCTOR CONNECTED
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
VENT PIPE
AutoCAD SHX Text
2'-0" (MIN.)
AutoCAD SHX Text
CLIP CABLE SUPPORT
AutoCAD SHX Text
AIR TERMINAL
AutoCAD SHX Text
SEALING WASHER
AutoCAD SHX Text
MAIN CONDUCTOR
AutoCAD SHX Text 1/2" x 12" SOLID CU AIR TERMINAL
AutoCAD SHX Text FLAT MOUNT POINT BASE - Alum
AutoCAD SHX Text 24str x 14ga BARE CU CONDUCTOR
BIMETAL CABLE SPLICER
| 1. GI 001 Cover Sheet |
| Sheets and Views |
| GI 001 Cover Sheet |
| 2. GI 002 Index |
| Sheets and Views |
| GI 002 Index |
| 3. GI 003 Work Location |
| Sheets and Views |
| GI 003 Work Location |
| 4. AD 101 Demolition |
| Sheets and Views |
| AD 101 Demolition |
| 5. AE 101 New Work |
| Sheets and Views |
| AE 101 New Work |
| 6. AE 301 Elevations |
| Sheets and Views |
| AE 301 Elevations |
| 7. AE 501 Exterior Section Details |
| Sheets and Views |
| AE 501 Exterior Section Details |
| 8. AE 502 Exterior TPO Lap Details |
| Sheets and Views |
| AE 502 Exterior TPO Lap Details |
| 9. AE 503 Electrical Details |
| Sheets and Views |
| AE 503 Electrical Details |
File details come from the government source that posted it. Updated .