This document is a detailed Exhibit B.1 specification for a Readjustment Counseling Service (RCS) Vet Center facility, outlining comprehensive architectural, security, and technology requirements for a new VA facility. The specifications cover extensive details for each room, including floor materials, wall treatments, electrical and data infrastructure, security systems, and specialized equipment needs, with a focus on creating a functional and secure environment for veterans seeking counseling services.
Key requirements include a fully serviced lease with utilities, janitorial services, and technology infrastructure, specialized room designs for counseling and group therapy spaces, and robust security measures such as a Facility Security Level II designation, video surveillance system, intrusion detection, duress alarms, and controlled access protocols. The facility will feature multiple specialized areas including a lobby, reception, counseling offices, group therapy rooms, kitchen, storage spaces, and a telecommunications room, with specific technical specifications for each space to support veteran services and administrative operations.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10RCS/STA703 VET CENTER Page 1 | 25 Lessor Initials: ________________Date: ______________
READJUSTMENT COUNSELING SERVICE
VET CENTER
AGENCY SPECIFIC REQUIREMENTS
A. TYPICAL BUILDING LAYOUT AND SPACE REQUIREMENTS
1. The Lease shall be Fully Serviced with the following services paid for/provided by the Lessor through the annual rent.
a. Utilities.
b. Janitorial.
c. Basic Cable to include local channels in the Waiting Area (Lobby) and three Group Rooms.
d. Guest Business High-Speed Internet Wi-Fi.
e. System and CCTV Monitoring and Maintenance provided by the Lessor and paid through the annual rent.
f. Security system tested quarterly by the Lessor; a copy of the report sent to VA.
g. Preventative and corrective maintenance, to include software/ hardware updates and upgrades, if required, for all equipment, fixtures, systems, and signage listed in Lease and/or Exhibits.
h. All overtime HVAC usage shall be included in the annual rental rate.
B. TYPICAL BUILDING LAYOUT AND SPACE REQUIREMENTS
1. Please refer to the RLP Exhibit, Space Requirements for additional details to include the number of offices required for this location.
Space design will provide maximum co-location of the staff offices and group rooms.
Approximate room sizes and conceptual floorplan examples are included in this section.
LOBBY/WAITING - 245sf EDUCATION/RESOURCE - 80sf RESTROOM, FAMILY - 80sf GROUP ROOM 1 - 480sf GROUP ROOM 2 - 240sf GROUP ROOM 3 – 160sf
RECEPTION / PROGRAM SUPPORT (combined) - 160sf VET CENTER DIRECTOR - 150sf COUNSELORS - 144sf OUTREACH SPECIALIST - 144sf
COPY/MAIL - 120sf STORAGE – 120sf OIT DATA CLOSET – 80sf KITCHEN – 160sf HOUSEKEEPING - 40sf
RLP: 36C24525R0018 EXHIBIT B.1 Page 1 of 25
10RCS/STA703 VET CENTER Page 2 | 25 Lessor Initials: ________________Date: ______________
RLP: 36C24525R0018 EXHIBIT B.1 Page 2 of 25
10RCS/STA703 VET CENTER Page 3 | 25 Lessor Initials: ________________Date: ______________
RLP: 36C24525R0018 EXHIBIT B.1 Page 3 of 25
10RCS/STA703 VET CENTER Page 4 | 25 Lessor Initials: ________________Date: ______________
C. ROOM REQUIREMENTS
1. ENTRANCE / EXTERIOR Floor. a. Luxury Vinyl Tile/Plank 5mm thickness + 20mil wear layer; continues through hallway corridor.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
c. Wall base. Vinyl wall base in all rooms/spaces.
Ceiling. d. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. e. N/A.
Door. f. Power Assisted Front Entrance Door operated by push pad on both sides of the door.
Sound Isolation. g. N/A.
Data. h. N/A.
Electric. i. Mobile Vet Center (MVC). One (1) Exterior 50 AMP outlet with dedicated circuit for the (MVC) enclosed in weatherproof and locking RV Power Outlet Box; location determined by the VA.
Lighting. j. Multilevel Switching, Dimming & Occupancy.
Safety. k. Cameras. Exterior cameras to provide unobstructed monitoring of pedestrian exits and parking area.
l. Cameras. Interior cameras to provide unobstructed monitoring of entrances.
m. Physical Access Control System, refer to VA Security Level II for shell and tenant improvement requirements.
n. Lighted “EXIT” signs with battery backup.
RLP: 36C24525R0018 EXHIBIT B.1 Page 4 of 25
10RCS/STA703 VET CENTER Page 5 | 25 Lessor Initials: ________________Date: ______________
Key Control, Access. o. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
p. Entry control system allowing VA staff ability to view, communicate, and open the door remotely before allowing access to space.
Other. q. Vestibule. Vestibule provided at public entrance where weather conditions and heat loss are important factors.
r. Flagpole for displaying the US Flag near building or public main entrance; flag shall be illuminated during the hours of darkness.
2. LOBBY, WAITING AREA Floor. a. Luxury Vinyl Tile/Plank 5mm thickness + 20mil wear layer; continues through hallway corridor.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
RLP: 36C24525R0018 EXHIBIT B.1 Page 5 of 25
10RCS/STA703 VET CENTER Page 6 | 25 Lessor Initials: ________________Date: ______________
Ceiling. c. Acoustical Ceiling Panels HIGH-NRC/HIGH-CA; standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. d. Direct window access.
e. Window Coverings. Horizontal manual roller shades with solar glare and heat reduction.
Door. f. Full-length glass panel. (Qty 2).
Sound Isolation. g. STC 45. Vet Center requirement is STC 45.
Data. h. One (1) duplex date behind TV; 60” from the floor.
Electric. i. One (1) per wall duplex outlet.
j. Cable TV wall jack, HDMI, and quadruplex Electrical outlet behind the TV; 60” from the floor.
Lighting. k. Multilevel Switching, Dimming & Occupancy.
Safety. l. Interior cameras monitoring of the entrance, waiting area, main corridor, and telecommunications room.
Key Control Access. m. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
Other. n. Corridors minimum of 5 feet in clear width.
o. Vinyl Corner Guards. Mounted at height 48” from top of vinyl base in hallways.
p. Wall Backing and Mounting Materials to support 60” VA furnished television installed by Lessor; location determined by VA.
q. Drinking Fountain. Wall hung stainless Bottle Filling Station Single ADA Cooler; Maintenance/filter replacement by
Lessor.
RLP: 36C24525R0018 EXHIBIT B.1 Page 6 of 25
10RCS/STA703 VET CENTER Page 7 | 25 Lessor Initials: ________________Date: ______________
3. RESTROOM (UNISEX) Floor. a. Porcelain Floor Tile.
Wall. b. Porcelain Wall Tile 4 feet up from the floor, with tile accent strip.
c. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. d. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC; standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. e. N/A.
Door. f. Power Assisted Door operatized by a push pad on both sides of the door.
Sound Isolation. g. STC 45. Vet Center requirement is STC 45.
RLP: 36C24525R0018 EXHIBIT B.1 Page 7 of 25
10RCS/STA703 VET CENTER Page 8 | 25 Lessor Initials: ________________Date: ______________
Data. h. N/A.
Electric. i. One (1) GFCI duplex outlet.
Lighting. j. Occupancy Sensor
Safety. k. ADA handicap accessibility to include grab bars at commode.
l. Nurse call tone-visual system. The notification sounds in corridors and at master station along with a visual call light above the room.
Key Control Access. m. Master keyed with locking mechanism on the inside of the frame.
Other: n. Toilet. Commercial Grade with automatic toilet flushers.
o. Toilet Paper Dispenser. Dual roll
p. Toilet Paper Cover Dispenser. Provided, maintained, and refilled by the Lessor.
q. Paper Towel Dispenser. Automated touchless dispenser provided, maintained, and refilled by the Lessor.
r. Soap Dispenser. Automated touchless dispenser provided, maintained, and refilled by the Lessor Vanity with sink and structure to hide exposed plumbing.
s. Mirror. Minimum of 24"x 36" over sink
t. Built-in waste outlet.
u. Vanity.
v. Coat Hooks. Location determined by the VA.
w. Baby changing station.
RLP: 36C24525R0018 EXHIBIT B.1 Page 8 of 25
10RCS/STA703 VET CENTER Page 9 | 25 Lessor Initials: ________________Date: ______________
4. RECEPTION / PROGRAM SUPPORT
ASSISTANT
Floor. a. Luxury Vinyl Tile 5mm thickness + 20mil wear layer.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. c. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. d. Horizontal manual roller shades with solar glare and heat reduction.
e. Glass transaction window to the lobby area.
Door. f. Solid Core Wood Doors with soundproofing jamb and threshold seals.
Data. h. Three (3) duplex outlets next to quad Electrical outlets.
Electric.
i. Three (3) quad outlets next to duplex Data outlets.
j. One (1) duplex Electrical outlet at counter height.
Lighting. k. Multilevel Switching, Dimming & Occupancy.
Safety. l. Duress Alarm. Hardwired transmitter device (Qty 2)
m. Ai Phone Video Master Station. Located in the Reception/Program Support office; specific location determined by
VA.
Key Control Access. n. Master keyed with locking mechanism on inside of frame.
RLP: 36C24525R0018 EXHIBIT B.1 Page 9 of 25
10RCS/STA703 VET CENTER Page 10 | 25 Lessor Initials: ________________Date: ______________
Other. o. Countertop. Solid Surface Quartz Countertop utilizing concealed mounting brackets where practicable.
p. Reception area contiguous with the Program Support Assistant; examples below.
5. OFFICE Floor. q. Carpet Tile.
Wall. r. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. s. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. t. Window Coverings. Horizontal manual roller shades with solar glare and heat reduction.
Door. u. Solid Core Wood Doors with soundproofing jamb and threshold seals.
Sound Isolation. v. STC 45. Vet Center requirement is STC 45.
RLP: 36C24525R0018 EXHIBIT B.1 Page 10 of 25
10RCS/STA703 VET CENTER Page 11 | 25 Lessor Initials: ________________Date: ______________
Data. w. Two (2) duplex outlets next to quad Electrical outlets.
Electric. x. Two (2) quad outlets next to duplex Data outlets.
y. Two (2) duplex outlets on the opposite walls.
z. Typical office layout diagram with data and electric placement.
Lighting. aa. Multilevel Switching, Dimming & Occupancy.
Safety. bb. Duress Alarm Wireless transmitter device.
Key Control Access. cc. Master keyed with locking mechanism on inside of frame.
Other. dd. Coat Hooks: Three (3) location determined by the VA.
6. GROUP THERAPY ROOM Floor. a. Carpet Tile.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. c. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and
RLP: 36C24525R0018 EXHIBIT B.1 Page 11 of 25
10RCS/STA703 VET CENTER Page 12 | 25 Lessor Initials: ________________Date: ______________
Window. d. Window Coverings. Horizontal manual roller shades with solar glare and heat reduction.
Door. e. Solid Core Wood Doors with soundproofing jamb and threshold seals.
Sound Isolation. f. STC 45. Vet Center requirement is STC 45.
Data. g. Four (4) duplex outlets; one on each wall.
h. Fur (4) duplex outlets; one on each wall, next to data outlets.
i. Wall backing and mounting materials for VA furnished television installed by Lessor; location determined by VA.
Lighting. j. Multilevel Switching, Dimming & Occupancy.
Safety. k. Duress Alarm Hardwired transmitter device with protective clear cover.
Key Control Access. l. Master keyed with locking mechanism on inside of frame.
Other. m. Coat Hooks: Three (3) location determined by the VA.
RLP: 36C24525R0018 EXHIBIT B.1 Page 12 of 25
10RCS/STA703 VET CENTER Page 13 | 25 Lessor Initials: ________________Date: ______________
7. KITCHEN EMPLOYEE BREAK ROOM Floor. a. Luxury Vinyl Tile 5mm thickness + 20mil wear layer.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
c. Perimeter walls extend from floor slab or 12 inches above the ceiling grid and fill with fiberglass bat insulation.
Ceiling. d. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. e. N/A.
Door. f. Solid Core Wood Doors with soundproofing jamb, threshold seals, soft closing door feature
RLP: 36C24525R0018 EXHIBIT B.1 Page 13 of 25
10RCS/STA703 VET CENTER Page 14 | 25 Lessor Initials: ________________Date: ______________
Data. h. Two (2) duplex outlets next to quadraplex Electrical outlets. (See diagram)
i. One (1) duplex GFI outlet for refrigerator.
j. Two (2) duplex GFI outlets at counter height.
k. Three (3) duplex outlets, one on each wall, 18” from floor.
Lighting. x. Occupancy Sensor
Safety. l. Duress Alarm Wireless transmitter device.
Key Control Access. m. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
Other. n. Coat Hooks: Three (3) location determined by the VA.
o. Cabinets. Upper and lower kitchen cabinets.
p. Countertop. Minimum 10’ feet solid surface countertop (Quartz or Corian).
q. Sink. Double compartment stainless sink.
r. Garbage Disposal.
s. Dishwasher provided by the Lessor.
t. Microwave Oven (1.7 cu. ft. minimum) provided by the Lessor.
u. Refrigerator (20-25 cu. ft. minimum) with water feed and ice maker provided by the Lessor.
RLP: 36C24525R0018 EXHIBIT B.1 Page 14 of 25
10RCS/STA703 VET CENTER Page 15 | 25 Lessor Initials: ________________Date: ______________
8. HOUSEKEEPING
Floor. a. Sealed concrete floor.
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. c. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC; standard size 24’ x24” x 1” with laminated or sealed face and
Window. d. N/A.
Door. e. Solid Core Wood Door.
Sound Isolation. f. N/A.
Data. g. N/A.
Electric. h. Two (2) duplex GFCI outlets.
Lighting.
i. Occupancy Sensor.
Safety. j. N/A.
Key Control Access. k. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
Other l. Shelving. Adjustable wire shelving on two walls.
m. Sink. Mop Sink.
9. SUPPLY ROOM Floor. - Luxury Vinyl Tile (LVT) 5mm thickness + 20mil wear layer.
RLP: 36C24525R0018 EXHIBIT B.1 Page 15 of 25
10RCS/STA703 VET CENTER Page 16 | 25 Lessor Initials: ________________Date: ______________
Wall. - Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
Ceiling. - Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC, standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. - N/A.
Door. - Solid Core Wood Doors with soundproofing jamb and threshold seal, soft closing door feature.
Sound Isolation. - N/A.
Data. - Two (2) duplex outlets, next to quadraplex electrical outlets.
Electric. - Two (2) quadraplex outlets, next to data outlets. Two (2) duplex outlets at counter height.
Lighting. y. Occupancy Sensor
Safety. - N/A.
Key Control Access. n. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
Other: o. Cabinets. Casework cabinetry and counter provided by VA furniture vendor.
p. Lessor provided and installed independent network switch and IP address to support the Cable television, Business
High Speed Internet Wi-Fi Router, and Security Alarm Control Panel; final location determined by VA.
10. STORAGE ROOM Floor. a. Luxury Vinyl Tile (LVT) 5mm thickness + 20mil wear layer
Wall. b. Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
RLP: 36C24525R0018 EXHIBIT B.1 Page 16 of 25
10RCS/STA703 VET CENTER Page 17 | 25 Lessor Initials: ________________Date: ______________
Ceiling. c. Acoustical Ceiling Tile panels HIGH-NRC/HIGH-CAC; standard size 24’ x24” x 1” with laminated or sealed face and sealed edges.
Window. d. Not required.
Door. e. Solid Core Wood Doors with soundproofing jamb and threshold seal, soft closing door feature.
Sound Isolation. f. N/A
Data. g. Four (4) duplex outlets, one per wall.
Electric. h. Four (4) duplex outlets, one per wall next to data outlets.
Lighting. i. Occupancy Sensor
Safety. j. N/A
Key Control Access. k. Access Controlled Door with electronic pin lever or electronic card access locking mechanism.
11. TELECOMMUNICATION DATA
CLOSET
⁻ The Lessor shall provide all equipment, material, parts, and labor to complete the room requirements.
⁻ Please refer to OIT Design Guide Templates, OIT IS Appendix B which begin on page 149 of the Infrastructure Standard for Telecommunications Spaces InfrastrucStdTelecommSpaces. https://www.cfm.va.gov/til/dguide/OIT- InfrastrucStdTelecommSpaces.pdf and Telecommunications Data Center and Infrastructure Engineering Design Standards - Office of Construction & Facilities Management https://www.cfm.va.gov/til/telecom.asp
Floor. - Sealed Concrete Floor.
Wall. - Paint all rooms/spaces with primer and two finish coats walls and accent walls color; location determined by VA.
- All perimeter walls extend from floor slab to structural system (deck) to prevent up and over access.
- No windows or other openings.
- Fire rated ¾” plywood backboard (rating must be visible) for mounting service provider, security, video, and similar equipment.
Ceiling. - No ceiling.
Window. - No windows.
RLP: 36C24525R0018 EXHIBIT B.1 Page 17 of 25
10RCS/STA703 VET CENTER Page 18 | 25 Lessor Initials: ________________Date: ______________
Door.
- Metal frame with dead lock pin, automatic locking upon entry and exit.
- Solid Core Wood Door or metal door with the veneer to match the existing suite doors. Global 5.06), Global 5.07)
- Electronic lock with pin lever or electronic key card entry system and door lock.
- Metal frame door with dead lock pin, automatic locking upon entry and exit for a secure room.
- Automatic door closure installed, with mortise lockset and deadbolt lock according to VA security regulations.
Sound Isolation. - N/A
Data.
- Standard Data Outlets: Each data outlet device location will have four (4) Work Area Outlet (WAO) Standard Density design cable runs that terminate on the high-density rack mounted patch panel in the Telecommunications Room.
- One cable is dedicated to a VoIP phone. The second WAO your backup/redundant line. The VoIP phone plugs into the WAO, and the user’s laptop/desktop plugs into the back of the VoIP phone. The combined VoIP/laptop connection uses one (1) active data port on the switch, decreasing the number of Networks switches.
q. Location of Data Outlets. Flush-mounted single-gang outlet boxes with four-port base plates and applicable wall device faceplates (cable installed behind wall/drywall with protective insulator or sleeve
r. VA naming and labeling. Attach printed, easily visible labels at the patch panel and wall plate. Refer to section 5.1.5, Information Transport Systems Equipment and Component Labeling, of the Infrastructure Standard for Telecommunications Spaces.
s. Four (4) quadraplexes Electrical 120V 20A convenience power outlet with NEMA 5-15/20 outlets on each wall to support the network rack.
t. Two (2) quadraplex Electrical outlets, centrally mounted above ladder rack system.
u. Two (2) each L5-30 locking outlets on separate circuits for redundancy.
v. One (1) single-phase 120V L5-30 input.
w. One (1) single-phase L5-30 output rack-mounted UPS supporting up to 2880VA of equipment load and providing ten
(10) minutes of battery backup.
x. Two (2) zero-U vertical rack PDUs with L5-30 inputs and a minimum of six (6) each NEMA 5-15 outlets to support IT equipment.
y. One rack PDU shall be powered via the UPS.
Lighting. z. Occupancy/vacancy
aa. Overhead lighting in front and back of the network rack.
RLP: 36C24525R0018 EXHIBIT B.1 Page 18 of 25
10RCS/STA703 VET CENTER Page 19 | 25 Lessor Initials: ________________Date: ______________
Safety bb. Intrusion Detection alarm to detect entry into the room with local audible alarm.
cc. A remote, key operated activation/deactivation switch installed outside the room and adjacent to the room entrance door frame and/or a central alarm ON-OFF control.
dd. An automatic reset capability following intrusion detection.
ee. Locally sounding alarm, remote visual and/or audio annunciators must be at a location within the facility which ensures 24-hour monitoring.
ff. Motion Sensor Lights activate upon entry; sufficient lighting installed for safe passage and to permit Security Camera identification in the space.
Key Control Access. gg. Access to Telecommunications Room restricted to VA OIT; not to include facility Lessor or another tenant.
hh. Physical Access Control to the space to include a VA cored lock, access card or fob, and PIN number, as a secondary authentication.
- Electronic Physical Access Control System is a card reader activated by card or fob.
ii. Access controls to the space include VA cored lock, the ability to scan a card or fob, followed by a PIN number as a secondary authentication.
jj. VA Cored Lock. Provide BEST 7-pin Standard Form Interchangeable Core Cylinder provide to VA for VA OIT TR keying, return to Lessor for installation.
Other. kk. Temperature. Controlled and maintained at 69 degrees on a 24x7 basis; Lessor provided mini split HVAC system.
ll. DEMARC.
- Provide, install, and coordinate with local exchange carrier (LEC) to bring fiber and copper infrastructure into the Telecom Room.
- One conduit pathway from TR point of demarcation to connect the building with AT&T or local exchange carrier.
- Distance between the building DEMARC and the intended closet for the VA, less than 328 feet.
- A direct run from the street, where the circuits enter the building, to the wall or rack is preferred.
- Sizing of conduits must be based on a 40 percent fill.
- All telecommunications services terminated in the TR.
mm. CAT6A performance.
- All installed untwisted shielded pair (UTP) copper distribution elements (patch panels, jacks, cables, and work area outlet (WAO) jacks) for network data transmission require CAT 6A.
- Lessor shall test and certify performance; test results provided to VA COR.
nn. Rack.
- One (1) 45U network (24wX48dX80h) four post channel rack with vertical cable management.
RLP: 36C24525R0018 EXHIBIT B.1 Page 19 of 25
10RCS/STA703 VET CENTER Page 20 | 25 Lessor Initials: ________________Date: ______________
- Rack secured to the floor and seismically braced to the building.
- Provide minimum 3-foot clearance on front and rear sides of the rack.
- Data racks shall have vertical and horizontal organizers affixed.
- Cable tray ladder rack from the wall to the top of relay rack, allowing for a pathway to conduits and 110 blocks.
oo. Patch Panels/Horizontal Cable Management.
- Provide 1RU (rack unit) of horizontal cable management equipment above and below each patch panel.
- Patch panels placed in the front top 1/3 of the network rack (RUs 31-45).
- Patch Panels, jacks, and cables require CAT 6A and shall be tested and certified; test results provided to VA COR.
- The number of patch panels is equal to the total number of work area outlets (WAO), running back to the
Telecommunication Space, divided by 48, rounded up. Each patch panel and switch RU has 48 ports; assume that you will need ½ the number of switches as you have patch panels, plus one.
pp. UPS.
⁻ Rack-mounted uninterruptible power supply (UPS) and power distribution unit (PDU) equipment at the bottom of the network rack, beginning at RU1.
⁻ Bonding. Bonding system compliant with the requirements of ANSI/TIA-607-D to include Primary Bonding
Busbar (PBB), Rack Bonding Busbar (RBB), Telecommunications Equipment Bonding Conductor (6 AWG), and Rack Bonding Conductor (6 AWG). Install RBB in the top rear RU position in the network rack. Network rack and cable tray sections shall be bonded. Unit Bonding Conductors (UBCs) and their connection to the RBB and network equipment by others.
D. FINISHES
a. The Lessor shall provide physical samples for VA final approval; VA will provide a digital Color Board.
b. Repaint the space every 5 years.
c. Lessor shall maintain all wall covering and paint coatings in “like new” condition for the life of the Lease. All repainted surfaces are at the Lessor’s expense, including the moving and returning of furnishings.
d. Replace flooring in the space every 5 years.
e. Lessor shall repair or replace flooring at any time during the life of the. All repaired or replaced flooring surfaces are at the Lessor’s expense, including the moving and returning of furnishings.
f. Examples.
RLP: 36C24525R0018 EXHIBIT B.1 Page 20 of 25
10RCS/STA703 VET CENTER Page 21 | 25 Lessor Initials: ________________Date: ______________
E. SOUND ISOLATION CLASS (STC)
a. Install sound blocking and noise-blocking wall construction between rooms and in ceiling throughout the space to meet the STC 45 Vet Center specific requirement.
b. Lessor shall conduct a Sound Acoustic Field Study to assure the acoustical requirements meet the Vet Center specific requirements.
c. Examples which may help achieve a sound resistant enclosure:
Door Thickness 2 ¼”-2 ¾”, Sound Dampening Cores, Glass Insert Doors 1” insulated glass with ¼” laminated glass on both sides, soundproofing jamb seal, threshold seal, Acoustical Ceiling Insulation 3 ½”, Acoustical Ceiling Panel Tiles, Walls floor to deck or 12-18” above ceiling, Walls with two layers 5/8”); Metal Studs 20-24” spacing, and Rockwool Sound insulation or equal.
F. SOUND MASKING SYSTEM
RLP: 36C24525R0018 EXHIBIT B.1 Page 21 of 25
10RCS/STA703 VET CENTER Page 22 | 25 Lessor Initials: ________________Date: ______________
a. Lessor shall design, provide equipment, install, maintain, and complete software updates.
b. Sound masking system to consist of a series of ceiling speakers installed in a grid-like pattern, with a method of controlling the speaker’s output.
c. System shall use small adjustment zones to offer control volume and frequency.
d. System zones to include lobby, corridors, and each group room.
e. System reports to master station; location determined by VA.
G. SIGNAGE
1. EXTERIOR SIGNAGE a. Refer to Exhibit SOW ASR-B RCS Exterior Signage Guide for specifications and requirements associated with the exterior signage.
b. Preferred Option is an exterior sign with the Vet Center logo on building, above the entrance.
c. VA approval is required prior to fabrication and installation
d. Signage shall be legible from main serving road.
e. Signage shall comply with local municipality codes, maximum size in accordance with local building code.
2. MAIN ENTRY DOOR a. Provide main entry door decal signage.
3. INTERIOR SIGNAGE v. Refer to Exhibit SOW ASR-B RCS Interior Signage Guide for specifications and requirements associated with the exterior signage.
w. Provide interior signage for a standard wall sign, ADA compliant braille sign.
RLP: 36C24525R0018 EXHIBIT B.1 Page 22 of 25
10RCS/STA703 VET CENTER Page 23 | 25 Lessor Initials: ________________Date: ______________
H. SECURITY
1. Facility Security Level (FSL) II a. Refer to Facility Security Level (FSL) requirements exhibit included in the lease for all shell and tenant improvements requirements.
b. Lessor shall design, provide equipment, install, maintain, and complete software updates.
c. No public access to the offices will be allowed.
d. Security System Monitoring and Maintenance provided by the Lessor and paid through the annual rent.
e. Security system tested quarterly by the Lessor; a copy of the report sent to VA.
2. VIDEO SURVEILLANCE SYSTEM (VSS) a. Lessor shall design, provide equipment, install, complete software updates and provide preventive maintenance for all security systems.
b. Provide independent network switch and IP address to support the system; location determined by VA (Supply/Storage Room).
c. 100% browser-based, requiring no server or software installation.
d. Single cabinet, stand-alone system reports to a master station with monitor; location determined in coordination with the VA.
e. VSS to support the ePACS.
f. Provide two (2) tablets with the system software for security monitoring.
g. Cameras (exterior) installed to provide unobstructed coverage of pedestrian entrances and exits.
h. Cameras (interior) installed in the waiting/lobby, the main corridors, and telecommunications room entrance.
i. CCTV system supports the entry control system, 30-day time-lapse video recording.
j. CCTV system testing is required prior to occupancy.
3. INTRUSION DETECTION SYSTEM (IDS) a. Activate audible sound throughout the space upon illegal/unauthorized entry.
b. Alarm system keypad to arm/disarm IDS at interior employee entrance/exit. Location determined in coordination with VA.
c. Alarm sensors on all exterior doors and windows, and telecommunication room door.
d. Motion sensors to cover the lobby, main corridors, and telecommunication room.
e. Alarm panel location determined by VA.
f. Employee access code updates coordinated with lessor as required for the duration of lease term.
g. Telecommunications room additional features:
- A remote, key operated activation/deactivation switch installed outside the room and adjacent to the room entrance door frame and/or a central alarm ON-OFF control.
- An automatic reset capability following intrusion detection.
RLP: 36C24525R0018 EXHIBIT B.1 Page 23 of 25
10RCS/STA703 VET CENTER Page 24 | 25 Lessor Initials: ________________Date: ______________
h. Locally sounding alarm, remote visual and audio annunciators must be at a location within the facility which ensures 24-hour monitoring.
4. DURESS ALARM a. Lessor shall design, provide equipment, install, maintain, and complete software updates for the Duress Alarm system.
b. Interface with the IDS.
c. System reports to master station; location determined by VA.
d. Master station displays the transmitter device location upon call notification.
e. Each transmitter device is individually zoned.
f. Hardwired duress installed in each restroom and group room.
g. Wireless duress installed at reception desk and in each office.
h. When activated, a notification sounds through the hallways/corridors and the central monitoring center is alerted.
i. Duress Alarm System alerts the alarm company, which then contacts the Vet Center to determine the required course of action.
5. NURSE CALL a. Nurse call tone-visual system. The notification sounds in corridors and at master station along with a visual call light above the room.
6. TELECOMUNICATIONS ROOM
a. Access to Telecommunications Room restricted to VA OIT; not to include facility Lessor or another tenant.
b. Physical Access Control to the space to include a VA cored lock, access card or fob, and PIN number, as a secondary authentication.
- Electronic Physical Access Control System is a card reader activated by card or fob.
c. Access controls to the space include VA cored lock, the ability to scan a card or fob, followed by a PIN number as a secondary authentication.
d. VA Cored Lock. Provide BEST 7-pin Standard Form Interchangeable Core Cylinder provide to VA for VA OIT TR keying, return to Lessor for installation.
e. Refer to Exhibit C, VA Security Requirements for Level II for Telecom shell and tenant improvement requirements.
1.0 SITE SECURITY CRITERIA, 1.6 RESTRICTED AREAS OR SIGNIFICANT AREAS AND ASSETS: (SHELL) 4.0 INTERIOR SECURITY CRITERIA, 4.3 SECURITY OF CRITICAL AREAS (i.e., PHARMACY or TELECOM ROOMS): (TI).
7. BUILDING AND ACCESS CONTROL SYSTEMS
a. Lessors are prohibited from connecting any portion of their building and access control systems (BACS) to any Federally Owned or Operated IT Network/Telecommunication Room.
b. BACS include systems providing fire and life safety control, physical access control, building power, energy control, electronic surveillance, and automated HVAC, elevator, or building monitoring and control services (including IP addressable devices, application servers, or network switches).
RLP: 36C24525R0018 EXHIBIT B.1 Page 24 of 25
10RCS/STA703 VET CENTER Page 25 | 25 Lessor Initials: ________________Date: ______________
c. The Lessor shall provide an independent network switch and IP address to support the Cable television, Guest Wi-Fi Router, and Security Alarm Control Panel; location determined by VA.
RLP: 36C24525R0018 EXHIBIT B.1 Page 25 of 25