This document package includes construction drawings and specifications for a roof replacement project at a Department of Veterans Affairs medical center. The project involves replacing roofs on Buildings 1 and 12, including new insulation, cover boards, roof membranes, flashings, and appurtenances. Key details include specifications for modified bitumen roof systems; drawings showing existing conditions and demolition plans; enlarged roof plans delineating wind zones and technical details for flashing penetrations, drains, scuppers, and other elements. Completion is required by an unspecified date. The solicitation number and agency - Z1DA-603-18-301 from the Veterans Health Administration - are provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 - A0004 - Attachment 1 - Drawing A113.pdf | ||
| 36C24921R0066 0004.docx | DOCX document | |
| S06 - Attachment 1 - Questions and Answers.pdf | ||
| S06 - A0003 - Amendment 0003 - questions and answers.pdf | ||
| 36C24921R0066 0003.docx | DOCX document | |
| S06 - Attachment 2 - Addendum 1 603-18-301 Replace Roofs Phase 1.pdf | ||
| 36C24921R0066 0002.docx | DOCX document | |
| S04 - SITE VISIT SIGN IN SHEET - 603-18-301 - Replace Roofs Phase 1_ Buildings 1 and 12.pdf | ||
| 36C24921R0066 0001.docx | DOCX document | |
| 36C24921R0066_1.docx | DOCX document | |
| S02 - Specifications.pdf | ||
| S02 - Wage Determination - Jefferson County 02.pdf | ||
| S02 - Drawings - 1 of 2.pdf | ||
| S02 - Price Schedule (Project 603-18-301) 02.xlsx | XLSX spreadsheet | |
| S02 - Past Performance Questionaire.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOF 8A
ROOF 7A
(N.I.C)
ROOF BG
(N.I.C)
ROOF 2F(KITCHEN)
ROOF 8C
(N.I.C.)
ROOF 7B
ROOF 8B
(N.I.C.)
ROOF 1F
ROOF 1E
ROOF 10A (N.I.C)
ROOF 11A (N.I.C)
ROOF 2C
ROOF 2B
ROOF 3C
ROOF 1B
ROOF 2D.1
ROOF 1C
ROOF 9A
ROOF 7C
ROOF 1G
ROOF 2D.2
ROOF 9C
ROOF 8D
ROOF 4B
ROOF 4A.1
ROOF 4A.2
ROOF 4A
ROOF 5A
ROOF BD.1
ROOF BD.2
ROOF 4C
ROOF BA
(EMS DOCK)
ROOF 3B
ROOF 2A
ROOF 1A
ROOF BF
ROOF 5B
(N.I.C)
ROOF 5C
ROOF 6B
ROOF 3A
ROOF 3E
ROOF 2D
ROOF 3D
ROOF 2E
ROOF 4E
ROOF 5C.1
ROOF 4D
ROOF BC
(N.I.C)
ROOF BB
(N.I.C)
R O
O F
X
ROOF O
(N.I.C)
(N.I.C)
ROOF S
(SMOKE HOUSE)
ROOF 1G.1
R O
G
ROOF 1G.3
PRD
PRD
PRD
PRD
GU
GU
DS
PRD
PP
PP
PP
PP
PRD PRD
EF
EF
EF
EF
PP
PP
PP PP PP PP PP PP
PP
H H H
H H H
H
H
PRD
PRD
SVP
EF
EF
EF
EF EF EF
PRD
PRD
PRD
PRD
SVP
SVP
FPD
PRD
PRD
PRD
DS
DS
6'-0"
PRD
PRD
PRD
SVP
PRD
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
EF EF
EF
EF
EF
EF
EF
EF
SVP
SVP
SVP
SVP SVP SVP
PRD
ORD
PRD
ORD
GUDS DS
SVP
SVP
ORD
PRD
ORD
PRD
SVP
SVP
SVP
ORD
PRD
PP
PP
PP
PP
EF
PP
PRD
PRD
PRD
PRD
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
HVS
EF
PRD PRD
SVP
GU
DS
DS
GU
GU
EF
EF
EF
OSOS
SVP
SVP
SVP
HVS
EF
PRD
PRD
EF
SVP
HVS
PP
PP
PP
PP
PP
PP
SVP
SVP
SVP
HVS
EF EF
EF
RTU
RTU
PRD
PRD
SVP
SVP
SVP
PRD
PRD
SVP
EF
FPD
FPD
RTU
EF
EF
EF
EF
EF
FPD
FPD
SVP
SVP
SVP
SVP
PRD
FPD
FPD
SVP
SVP
PRD
EF
PP
SVP
SVP
SVP
SVP
HVS
PP
FPD
FPD
EF
EF
EF
EF
EF
RTU
PP
PP
PP
PP
PRD
PRD
PRD
EF
SVP
SVP
SVP
FPD
FPD
HVS
HVS
PP PP
PP
PP
PP
PP
PP
PP
PP
EF EF EF EF
H
PRD
PRD
SVP
PRD
SVP
EF
SVP
SVP
SVP
EF
EF
EF
FPD
FPD
PRD
ORD
PRD
ORD
EF
ORD
PRD
ORD
PRD
PRDORD
SVP
EF
SVP
SVP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
SA SA SA
PRD
PRD PRD
FPD FPD
SA
SA
PRD
PRD
EF EF EF
EF
EF
EF EF
RTU
EF
HVS
GU
GU
PRD
PP
PP PP
PP
PRD
SVP
PP
PP
PP
PP
EF
EF
PRD PRD
PRD
SVP
SVP
RTU
PRD
PRD
EF EF
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRDPRD
PRD
PP
PP
PP
PP
PP
PP PP
FPD
FPD
PP
SVP
SVP
SVP
SVP
RTU
SVP
SVP
FPD
SVP
PP
PP
EF
PRD
RTU
EF EF
SVP SVP
PRD
PRD
PRD
PRD
FPD
PP
PP
FPD
SVP
SVP
RTU
RTU
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRD
PRD
SVP
PP
PP
PP PP
EF
EF
EF
EF EF
EF
RTU
EF
EF
EF
EF
EF
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EF
EF
EF
EF
EF
PP
OS
PRD
FPD
SVP
RTU
EF
EF
PP
RTU
PRD
PRD
EF
PP
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
PP
PP
PP
PP
RTU
PRD
PRD
PRD
PRD
FPD
FPD
FPD
EF
EF
SVP
SVP
PP
PP
PP PP PP PP
PP
SVP
OS
OS
PRD
PRD
PRD PRD
PRD
PRD
EF
FPD
EF
OS
OS
OS
OS
SVP
FPD FPD
EF
EF
FPD
FPD
FPDFPD
PP
PP
SA
EF
EF
SVP
SVP
SVP
SVP
SVP
SVP
FPD
SA
EF
PP
FPD
PRD
FPD
FPD
SVP
FPD
HVS
FPD
PRD
SVP
RTU
EF
EF
EF
PRD
EF
EJ
EJ
SVP
SVP
SVP
SVP
EF
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
RTU RTU
PRD
PRD
OS
MATCH LINE A
MATCH LINE C
MATCH LINE B
MATCH LINE D
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
37'±1'-9"±
57'-8"±
19'-8"± 6'-5"± 14'-2"±
3'-8"±
59'-2"±
15'± 42'-9"± 26'±
41'-3"±
20'±
38'-8"±
19'-4"±
38'±
11'-6"±
33'-4"±
11'-7"±
37'-4"±
23'-8"±
16'-3"±
35'-6"±
37'-8"±
16'±
14'-1"±
21'-8"±
46'-7"±
31'-3"±
39'-4"±
40'-5"±
34'-11"±
12'-7"±
9'-1"±
99'-2"±
9'-9"±
4'±
16'-1"±
37'-4"±
18'±
45'±
25'-1"± 30'-3"± 56'-3"±
23'-5"±40'-4"±4'-4"±
16'-1"± 50'-5"±
5'-8"±
20'-3"±
15'-4"±34'-10"±
20'-3"±
29'-7"±
13'±
7'-3"±
2'-7"± 10'-5"±
8'-3"±
5'-2"±
5'-7"±
11'-6"±
40'-1"±
11'-2"±
40'-4"±
46'-2"±
37'-9"±
36'-2"±
5'-5"±
4'-7"±
10'-9"±
BUILDING 1 KEY PLAN
A B
C D
ROOF 9B
25'-2"±
(N.I.C)
(N.I.C)
(N.I.C)
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-101
BUILDING 1
OVERALL ROOF PLAN
N
SCALE: 1/16" = 1'-0"
BUILDING 1 OVERALL ROOF PLAN
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
A-109
1). ROOF AREAS 1C, 2A, 2F, 3C, 4A, 4E, 5A, 6B, 7A, 7B, 8A,
8C, 8D, 9B, 9C, BD.1, BD.2, BF & O: MODIFY EXISTING
SCUPPER TO RECEIVE A MINIMUM 4" x 10" SCUPPER
LINER.
2). ROOF AREAS 3A & 9A : MODIFY EXISTING SCUPPER
TO RECEIVE A MINIMUM 4" x 18" SCUPPER LINER.
3). ALL ROOF DRAIN LEADERS EXCEPT ROOF AREA 2E
TO BE MINIMUM 3" Ø (DIAMETER).
4). ROOF AREA 2E ROOF DRAIN LEADER TO BE MINIMUM
4" Ø (DIAMETER).
5). ROOF AREAS 1C, 4A.2, 5B & BA MINIMUM GUTTER
SIZE TO BE 4" x 4" AND DOWNSPOUTS TO BE 2" x 3".
6). ROOF AREAS 2A & 4B MINIMUM GUTTER SIZE TO BE
6" x 6" AND DOWNSPOUTS TO BE 4" x 5".
ADDENDUM 200914 9/14/20201
ROOF 8C
ROOF 7B
ROOF 8B
ROOF 1F
ROOF 1E
ROOF 10A (N.I.C)
ROOF 11A (N.I.C)
ROOF 2C
ROOF 2B
ROOF 3C
ROOF 1B
ROOF 2D.1
ROOF 1C
ROOF 9A
ROOF 7C
ROOF 1G
ROOF 2D.2
ROOF 9C
(N.I.C)
ROOF 1G.1
ROOF 1G.3
GU
PRD
PRD
SVP
GU
GU
PRD
PP
PP PP
PP
PRD
SVP
PP
PP
PP
PP
EF
EF
PRD PRD
PRD
SVP
SVP
RTU
PRD
PRD
EF EF
PRD
PRD
SVP
SVP
FPD
SVP
PP
PP
EF
PRD
RTU
EF EF
SVP SVP
PRD
PRD
PRD
PRD
FPD
PP
PP
FPD
SVP
SVP
RTU
RTU
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRD
PRD
SVP
PP
PP
PP PP
EF
EF
EF
EF EF
EF
RTU
EF
EF
EF
EF
EF
OS
OS
OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
EJ
EF
EF
EF
EF
EF
PP
OS
PRD
FPD
SVP
RTU
EF
EF
PP
RTU
PRD
PRD
EF
PP
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
PP
PP
PP
PP
RTU
PRD
PRD
PRD
PRD
FPD
FPD
FPD
EF
EF
SVP
SVP
PP
PP
PP PP PP PP
PP
SVP
OS
OS
PRD
PRD
PRD PRD
PRD
PRD
EF
FPD
EF
OS
OS
OS
OS
SVP
FPD FPD
EF
EF
FPD
FPD
FPDFPD
PP
PP
SA
EF
EF
SVP
SVP
SVP
SVP
SVP
SVP
FPD
SA
EF
PP
FPD
PRD
FPD
FPD
SVP
FPD
HVS
FPD
PRD
SVP
RTU
EF
EF
EF
RTU RTU
DS
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
37'±1'-9"±
57'-8"±
19'-8"± 6'-5"± 14'-2"±
3'-8"±
15'± 42'-9"±
20'±
38'-8"±
19'-4"±
38'±
11'-6"±
33'-4"±
11'-7"±
23'-8"±
16'-3"±
14'-1"±
21'-8"±
46'-7"±
31'-3"±
39'-4"±
40'-5"±
34'-11"±
25'-1"± 30'-3"±
56'-3"±
ROOF 9B
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
6 6
TYP.
(TO EDGE OF ROOF BEYOND)
17'-5"±
25'-1"± 42'-4"±
41'-7"± 30'-1"±6'±
36'-7"± 36'-5"±
45'-2"±
56'-9"±
26'-1"±
44'-11"± 41'-4"±
27'-9"±
(TO EDGE
OF ROOF
BEYOND)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-102
BUILDING 1 ENLARGED ROOF
PLAN DEMO - A
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN DEMO - A
REMOVE AND DISCARD EXISTING METAL FLASHINGS,
INSULATION, AND ROOFING MEMBRANE ACCORDING
TO SPECIFICATIONS. REPAIR EXISTING DECK AS
REQUIRED. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND STORE EXISTING LIGHTNING
PROTECTION SYSTEM. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION. REINSTALL PER
COMPLETION OF NEW WORK FOR EACH ROOF AREA
REMOVE AND DISCARD EXISTING LADDER. REFER TO
SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
REMOVE AND DISCARD EXISTING STONE COPING
JOINT SEALANT. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND DISCARD EXISTING EXPANSION JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD ABANDONED CURBS. REFER
TO SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
REMOVE AND DISCARD EXISTING SCUPPER LINER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
ROOF 8D
ROOF 6B
ROOF 3A
ROOF 3E
ROOF 2D
ROOF 3D
ROOF 2E
ROOF 4E
ROOF X1
ROOF O
ROOF S
(SMOKE HOUSE)
R O
PRD
SVP
EF
SVP
SVP
SVP
EF
EF
EF
FPD
FPD
PRD
ORD
PRD
ORD
EF
ORD
PRD
ORD
PRD
PRDORD
SVP
EF
SVP
SVP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
SA SA SA
PRD
PRD PRD
FPD FPD
SA
SA
PRD
PRD
EF EF EF
EF
EF
EF EF
RTU
EF
HVS
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRD
PP
PP
PP
PP
PP
PP PP
FPD
FPD
PP
SVP
SVP
SVP
SVP
RTU
OS
OS
PS
OS
OS
OS
OS
OS
OS
OS
EJ
EJ
PRD
PRD
PS
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
MATCH LINE B
MATCH LINE D
26'±
41'-3"±
16'±
12'-7"±
9'-1"±
99'-2"±
9'-9"±
4'±
16'-1"±
37'-4"±
30'-3"±
56'-3"±
8'-3"±
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
31'-10"±
35'-11"± 40'-1"±
45'-2"±
8'±
13'-6"±
TYP.
P
S
102'-3"±
17'±
(TO EDGE
OF ROOF
BEYOND)
(TO EDGE OF ROOF BEYOND)
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-103
BUILDING 1 ENLARGED
ROOF PLAN DEMO - B
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN DEMO - B
REMOVE AND DISCARD EXISTING METAL FLASHINGS,
INSULATION, AND ROOFING MEMBRANE ACCORDING
TO SPECIFICATIONS. REPAIR EXISTING DECK AS
REQUIRED. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND STORE EXISTING LIGHTNING
PROTECTION SYSTEM. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION. REINSTALL PER
COMPLETION OF NEW WORK FOR EACH ROOF AREA
REMOVE AND DISCARD EXISTING LADDER. REFER TO
SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
REMOVE AND DISCARD EXISTING STONE COPING
JOINT SEALANT. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND DISCARD EXISTING EXPANSION JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD ABANDONED CURBS. REFER
TO SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
REMOVE AND DISCARD EXISTING SCUPPER LINER.
ROOF BG
(N.I.C)
ROOF 2F(KITCHEN)
ROOF 4B
ROOF 4A.1
ROOF 4A.2
ROOF 4A
ROOF 5A
ROOF BD.1
ROOF BD.2
ROOF 4C
ROOF BA
(EMS DOCK)
ROOF BF
ROOF BC
ROOF BB
(N.I.C)
(N.I.C)
PRD
PRD
PRD
PRD
GU
GU
DS
PRD
PP
PP
PP
PP
PRD PRD
EF
EF
EF
EF
PP
PP
PP PP PP PP PP PP
PP
H H H
H H H
H
H
PRD
PRD
SVP
EF
EF
EF
EF EF EF
PRD
PRD
PRD
PRD
PRD
PRD
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
HVS
EF
PRD PRD
SVP
GU
DS
DS
GU
GU
EF
EF
EF
OSOS
SVP
SVP
SVP
HVS
EF
PRD
PRD
EF
SVP
HVS
PP
PP
PP
PP
PP
PP
SVP
SVP
SVP
HVS
EF EF
EF
RTU
PRD
PRD
SVP
SVP
SVP
PRD
PRD
SVP
EF
FPD
FPD
RTU
EF
EF
EF
EF
EF
FPD
FPD
SVP
SVP
SVP
SVP
PRD
FPD
FPD
SVP
SVP
PRD
EF
PP
SVP
SVP
SVP
SVP
HVS
PP
FPD
FPD
EF
EF
EF
EF
EF
RTU
PP
PP
PP
PP
PRD
PRD
PRD
EF
SVP
SVP
SVP
FPD
FPD
HVS
HVS
PP PP
PP
PP
PP
PP
PP
PP
PP
EF EF EF EF
H
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
EJ
EJ
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
59'-2"±
11'-7"±
37'-4"±
23'-8"±
35'-6"±
37'-8"±
40'-1"±
11'-2"±
40'-4"±
46'-2"±
37'-9"±
36'-2"±
5'-5"±
4'-7"±
34'-10"±
20'-3"±
29'-7"±
13'±
7'-3"±
2'-7"± 10'-5"±
5'-2"±
5'-7"±
11'-6"±
10'-9"±
15'-4"±
25'-2"±
ROOF 9A
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
(TO EDGE OF ROOF BEYOND)
44'-9"±
96'-2"±
30'-8"±
19'-10"±
27'-7"±
7'-3"±
59'-3"±
53'-9"±
(N.I.C)
(N.I.C)
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-104
BUILDING 1 ENLARGED
ROOF PLAN DEMO - C
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN DEMO - C
REMOVE AND DISCARD EXISTING METAL FLASHINGS,
INSULATION, AND ROOFING MEMBRANE ACCORDING
TO SPECIFICATIONS. REPAIR EXISTING DECK AS
REQUIRED. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND STORE EXISTING LIGHTNING
PROTECTION SYSTEM. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION. REINSTALL PER
COMPLETION OF NEW WORK FOR EACH ROOF AREA
REMOVE AND DISCARD EXISTING LADDER. REFER TO
SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
REMOVE AND DISCARD EXISTING STONE COPING
JOINT SEALANT. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND DISCARD EXISTING EXPANSION JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD ABANDONED CURBS. REFER
TO SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
REMOVE AND DISCARD EXISTING SCUPPER LINER.
ROOF 3B
ROOF 2A
ROOF 1A
ROOF 5B
ROOF 5C
ROOF 5C.1
ROOF 4D
(N.I.C)
H
H
PRD
PRD
SVP
SVP
FPD
PRD
PRD
PRD
DS
DS
6'-0"
PRD
PRD
PRD
SVP
PRD
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
EF EF
EF
EF
EF
EF
EF
EF
SVP
SVP
SVP
SVP SVP SVP
PRD
ORD
PRD
ORD
GUDS DS
SVP
SVP
ORD
PRD
ORD
PRD
SVP
SVP
SVP
ORD
PRD
PP
PP
PP
PP
EF
PP
OS
RTU
OS
OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
PRD
EF
EJ
EJ
SVP
SVP
SVP
SVP
EF
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
MATCH LINE B
MATCH LINE D
34'-3"±
18'±
45'±
23'-5"±40'-4"±4'-4"±
16'-1"± 50'-5"±
5'-8"±
20'-3"±
15'-4"±
TYP.
TYP.
TYP.
TYP.
20'±
42'-9"±
23'-3"±
24'-8"±
9'-11"±
12'-6"±
23'±
TYP.
(TO EDGE OF ROOF BEYOND)
(TO EDGE OF ROOF BEYOND)
70'-6"±
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-105
BUILDING 1 ENLARGED
ROOF PLAN DEMO - D
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN DEMO - D
REMOVE AND DISCARD EXISTING METAL FLASHINGS,
INSULATION, AND ROOFING MEMBRANE ACCORDING
TO SPECIFICATIONS. REPAIR EXISTING DECK AS
REQUIRED. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND STORE EXISTING LIGHTNING
PROTECTION SYSTEM. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION. REINSTALL PER
COMPLETION OF NEW WORK FOR EACH ROOF AREA
REMOVE AND DISCARD EXISTING LADDER. REFER TO
SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
REMOVE AND DISCARD EXISTING STONE COPING
JOINT SEALANT. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND DISCARD EXISTING EXPANSION JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD ABANDONED CURBS. REFER
TO SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
REMOVE AND DISCARD EXISTING SCUPPER LINER.
(N.I.C)
PS PS PS PS
PS
P S
P S
P S
OS
PP
EF
PRD
SVP
SVP SVP
PP
SVP
SVP
EF
SVP
EF
PP PP PP
EF
PP
PP
PP
EF
EF
EF
PP
PP PP PP PP
PP PP
PP
PP
PP
PP
ROOF A1
ROOF A2
104'-3"±
65'-11"±
TYP.
TYP.
RTU RTU RTU RTU
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-107
BUILDING 12
ROOF PLAN DEMO
N
SCALE: 1/4" = 1'-0"
BUILDING 12 ROOF PLAN DEMO
REMOVE AND DISCARD EXISTING METAL FLASHINGS,
INSULATION, AND ROOFING MEMBRANE ACCORDING
TO SPECIFICATIONS. REPAIR EXISTING DECK AS
REQUIRED. REFER TO SPECIFICATION 011100
SUMMARY OF WORK AND 024100 DEMOLITION
REMOVE AND STORE EXISTING LIGHTNING
PROTECTION SYSTEM. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION. REINSTALL PER
COMPLETION OF NEW WORK FOR EACH ROOF AREA
REMOVE AND DISCARD EXISTING LADDER. REFER TO
SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
REMOVE AND DISCARD EXISTING METAL COPING.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD EXISTING EXPANSION JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 024100 DEMOLITION
REMOVE AND DISCARD ABANDONED CURBS. REFER
TO SPECIFICATION 011100 SUMMARY OF WORK AND
024100 DEMOLITION
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
REMOVE AND DISCARD EXISTING SCUPPER LINER.
ROOF 8B
ROOF 1F
ROOF 1E
ROOF 10A (N.I.C)
ROOF 11A (N.I.C)
ROOF 2C
ROOF 2B
ROOF 3C
ROOF 1B
ROOF 2D.1
ROOF 1C
ROOF 9A
ROOF 7C
ROOF 1G
ROOF 2D.2
ROOF 9C
(N.I.C)
ROOF 1G.1
ROOF 1G.3
GU
PRD
PRD
SVP
GU
GU
PRD
PP
PP PP
PP
PRD
SVP
PP
PP
PP
PP
EF
EF
PRD PRD
PRD
SVP
SVP
RTU
PRD
PRD
EF EF
PRD
PRD
SVP
SVP
FPD
SVP
PP
PP
EF
PRD
RTU
EF EF
SVP SVP
PRD
PRD
PRD
PRD
FPD
PP PP
FPD
SVP
SVP
RTU
RTU
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRD
PRD
SVP
PP
PP
PP PP
EF
EF
EF
EF EF
EF
RTU
EF
EF
EF
EF
EF
OS
OS
OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
EJ
EF
EF
EF
EF
EF
PP
OS
PRD
FPD
SVP
RTU
EF
EF
PP
RTU
PRD
PRD
EF
PP
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
PP
PP
PP
PP
RTU
PRD
PRD
PRD
PRD
FPD
FPD
FPD
EF
EF
SVP
SVP
PP
PP
PP PP PP PP
PP
SVP
OS
OS
PRD
PRD
PRD PRD
PRD
PRD
EF
FPD
EF
OS
OS
OS
OS
SVP
FPD FPD
EF
EF
FPD
FPD
FPDFPD
PP
PP
SA
EF
EF
SVP
SVP
SVP
SVP
SVP
SVP
FPD
SA
EF
PP
FPD
PRD
FPD
FPD
SVP
FPD
HVS
FPD
PRD
SVP
RTU
EF
EF
EF
RTU RTU
DS
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
37'±1'-9"±
57'-8"±
19'-8"± 6'-5"± 14'-2"±
3'-8"±
15'± 42'-9"±
20'±
38'-8"±
19'-4"±
38'±
11'-6"±
33'-4"±
11'-7"±
23'-8"±
16'-3"±
14'-1"±
21'-8"±
46'-7"±
31'-3"±
39'-4"±
40'-5"±
34'-11"±
25'-1"± 30'-3"±
56'-3"±
ROOF 9B
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
RTU
RTU
TYP.
A-501
TYP.
A-501
TYP.
A-502
TYP.
A-503
TYP.
A-502
TYP.
A-502
TYP.
A-503
TYP.
A-502
TYP.
A-501
TYP.
LOW
A-501
TYP.
A-501
TYP.
A-501
TYP.
HIGH
A-501
TYP.
(TO EDGE OF ROOF BEYOND)
17'-5"±
25'-1"± 42'-4"±
41'-7"± 30'-1"±6'±
36'-7"± 36'-5"±
45'-2"±
56'-9"±
26'-1"±
44'-11"± 41'-4"±
27'-9"±
(TO EDGE
OF ROOF
BEYOND)
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-108
BUILDING 1 ENLARGED
ROOF PLAN NEW - A
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN NEW - A
1 FURNISH AND INSTALL NEW INSULATION, COVER
BOARD, ROOFING MEMBRANE, AND METAL
FLASHINGS ACCORDING TO SPECIFICATIONS.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK, 061000 ROUGH CARPENTRY, 072200 ROOF
BOARD INSULATION, 075216.11 COLD ADHESIVE
STYRENE-BUTADIENE-STYRENE MODIFIED
BITUMINOUS MEMBRANE ROOFING, 076000 FLASHING
AND SHEET METAL, 077100 ROOF SPECIALTIES,
077200 ROOF ACCESSORIES, AND 221400 FACILITY
STORM DRAINAGE
PROPERLY REINSTALL AND COMMISSION EXISTING
LIGHTNING PROTECTION. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION
3 FURNISH AND INSTALL NEW LADDER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 055000 METAL FABRICATIONS
4 FURNISH AND INSTALL NEW SEALANT AT STONE
COPING JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 079200 JOINT SEALANTS
5 FURNISH AND INSTALL NEW EXPANSION JOINT
BELLOW SYSTEM.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 077100 ROOF SPECIALITIES
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
6 FURNISH AND INSTALL NEW SCUPPER LINER.
SEE NOTES ON A-101 FOR SIZING REQUIREMENTS
7 FURNISH AND INSTALL NEW ROOF AREA DIVIDER
TAPERED INSULATION
/ CRICKET
WALKPADS
ROOF 3A
ROOF 3E
ROOF 2D
ROOF 3D
ROOF 2E
ROOF 4E
ROOF X1
ROOF O
ROOF S
(SMOKE HOUSE)
R O
PRD
SVP
EF
SVP
SVP
SVP
EF
EF
EF
FPD
FPD
PRD
ORD
PRD
ORD
EF
ORD
PRD
ORD
PRD
PRDORD
SVP
EF
SVP
SVP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
SA SA SA
PRD
PRD PRD
FPD FPD
SA
SA
PRD
PRD
EF EF EF
EF
EF
EF EF
RTU
EF
HVS
FPD
SVP
SVP
SVP
PRD
PRD
PRD
PRD
PP
PP
PP
PP
PP
PP PP
FPD
FPD
PP
SVP
SVP
SVP
SVP
RTU
OS
OS
PS
OS
OS
OS
OS
OS
OS
OS
EJ
EJ
PRD
PRD
PS
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
MATCH LINE B
MATCH LINE D
26'±
41'-3"±
16'±
12'-7"±
9'-1"±
99'-2"±
9'-9"±
4'±
16'-1"±
37'-4"±
30'-3"±
56'-3"±
8'-3"±
31'-10"±
35'-11"± 40'-1"±
45'-2"±
8'±
13'-6"±
TYP.
P
S
A-501
TYP.
A-501
TYP.
A-501
TYP.
A-503
TYP.
A-502
TYP.
A-502
TYP.
A-503
TYP.
A-503
TYP.
A-501
LOW
A-501
A-501
LOW
HIGH
102'-3"±
17'±
(TO EDGE
OF ROOF
BEYOND)
(TO EDGE OF ROOF BEYOND)
(N.I.C)
R O
X
ROOF O
SVP
SVP
PRDORD
SVP
PRD
PRD
PRD
PRD
OS
MATCH LINE B
MATCH LINE D
(N.I.C)
EXISTING HERRINGBONE
BRICK PATTERN
EXISTING 8" CLEANOUT
SCHEDULE 40 PVC
NEW SCHEDULE 40 PVC PIPE
REPLACE BRICK PAVER
HARDSCAPE SYSTEM
AS REQUIRED
A-503
CONNECT ROOF DRAINS WITH
NEW 3" PIPING
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-109
BUILDING 1 ENLARGED
ROOF PLAN NEW - B
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN NEW - B
1 FURNISH AND INSTALL NEW INSULATION, COVER
BOARD, ROOFING MEMBRANE, AND METAL
FLASHINGS ACCORDING TO SPECIFICATIONS.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK, 061000 ROUGH CARPENTRY, 072200 ROOF
BOARD INSULATION, 075216.11 COLD ADHESIVE
STYRENE-BUTADIENE-STYRENE MODIFIED
BITUMINOUS MEMBRANE ROOFING, 076000 FLASHING
AND SHEET METAL, 077100 ROOF SPECIALTIES,
077200 ROOF ACCESSORIES, AND 221400 FACILITY
STORM DRAINAGE
PROPERLY REINSTALL AND COMMISSION EXISTING
LIGHTNING PROTECTION. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION
3 FURNISH AND INSTALL NEW LADDER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 055000 METAL FABRICATIONS
4 FURNISH AND INSTALL NEW SEALANT AT STONE
COPING JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 079200 JOINT SEALANTS
5 FURNISH AND INSTALL NEW EXPANSION JOINT
BELLOW SYSTEM.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 077100 ROOF SPECIALITIES
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
7 CONNECT OUTLET OF ROOF DRAIN LEADER TO
UNDERGROUND SCHEDULE 40 PVC PIPING
N
SCALE: 1/8" = 1'-0"
COURTYARD DRAINAGE PLAN
6 FURNISH AND INSTALL NEW SCUPPER LINER.
SEE NOTES ON A-101 FOR SIZING REQUIREMENTS
TAPERED INSULATION
ROOF BG
(N.I.C)
ROOF 2F(KITCHEN)
ROOF 4B
ROOF 4A.1
ROOF 4A.2
ROOF 4A
ROOF 5A
ROOF BD.1
ROOF BD.2
ROOF 4C
ROOF BA
(EMS DOCK)
ROOF BF
ROOF BC
ROOF BB
(N.I.C)
(N.I.C)
PRD
PRD
PRD
PRD
GU
GU
DS
PRD
PP
PP
PP
PP
PRD PRD
EF
EF
EF
EF
PP
PP
PP PP PP PP PP PP
PP
H H H
H H H
H
H
PRD
PRD
SVP
EF
EF
EF
EF EF EF
PRD
PRD
PRD
PRD
PRD
PRD
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
SVP
HVS
EF
PRD PRD
SVP
GU
DS
DS
GU
GU
EF
EF
EF
OSOS
SVP
SVP
SVP
HVS
EF
PRD
PRD
EF
SVP
HVS
PP
PP
PP
PP
PP
PP
SVP
SVP
SVP
HVS
EF EF
EF
RTU
PRD
PRD
SVP
SVP
SVP
PRD
PRD
SVP
EF
FPD
FPD
RTU
EF
EF
EF
EF
EF
FPD
FPD
SVP
SVP
SVP
SVP
PRD
FPD
FPD
SVP
SVP
PRD
EF
PP
SVP
SVP
SVP
SVP
HVS
PP
FPD
FPD
EF
EF
EF
EF
EF
RTU
PP
PP
PP
PP
PRD
PRD
PRD
EF
SVP
SVP
SVP
FPD
FPD
HVS
HVS
PP PP
PP
PP
PP
PP
PP
PP
PP
EF EF EF EF
H
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
EJ
EJ
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
59'-2"±
11'-7"±
37'-4"±
23'-8"±
35'-6"±
37'-8"±
40'-1"±
11'-2"±
40'-4"±
46'-2"±
37'-9"±
36'-2"±
5'-5"±
4'-7"±
34'-10"±
20'-3"±
29'-7"±
13'±
7'-3"±
2'-7"± 10'-5"±
5'-2"±
5'-7"±
11'-6"±
10'-9"±
15'-4"±
25'-2"±
ROOF 9A
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
A-501
TYP.
A-501
TYP.
A-503
TYP.
A-502
TYP.
LOW
A-501
TYP.
A-502
TYP.
A-502
TYP.
A-503
TYP.
A-502
TYP.
A-502
TYP.
A-502
TYP.
A-502
TYP.
44'-9"±
96'-2"±
30'-8"±
19'-10"±
27'-7"±
7'-3"±
59'-3"±
53'-9"±
(N.I.C)
(N.I.C)
(N.I.C)
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-110
BUILDING 1 ENLARGED
ROOF PLAN NEW - C
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN NEW - C
1 FURNISH AND INSTALL NEW INSULATION, COVER
BOARD, ROOFING MEMBRANE, AND METAL
FLASHINGS ACCORDING TO SPECIFICATIONS.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK, 061000 ROUGH CARPENTRY, 072200 ROOF
BOARD INSULATION, 075216.11 COLD ADHESIVE
STYRENE-BUTADIENE-STYRENE MODIFIED
BITUMINOUS MEMBRANE ROOFING, 076000 FLASHING
AND SHEET METAL, 077100 ROOF SPECIALTIES,
077200 ROOF ACCESSORIES, AND 221400 FACILITY
STORM DRAINAGE
PROPERLY REINSTALL AND COMMISSION EXISTING
LIGHTNING PROTECTION. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION
3 FURNISH AND INSTALL NEW LADDER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 055000 METAL FABRICATIONS
4 FURNISH AND INSTALL NEW SEALANT AT STONE
COPING JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 079200 JOINT SEALANTS
5 FURNISH AND INSTALL NEW EXPANSION JOINT
BELLOW SYSTEM.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 077100 ROOF SPECIALITIES
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
6 FURNISH AND INSTALL NEW SCUPPER LINER.
SEE NOTES ON A-101 FOR SIZING REQUIREMENTS
TAPERED INSULATION
/ CRICKET
7 FURNISH AND INSTALL NEW ROOF AREA DIVIDER
ROOF 1A
ROOF 5B
ROOF 5C
ROOF 5C.1
ROOF 4D
(N.I.C)
H
H
PRD
PRD
SVP
SVP
FPD
PRD
PRD
PRD
DS
DS
6'-0"
PRD
PRD
PRD
SVP
PRD
EF
EF
PP
PP
EF
EF
EF
EF
EF
EF
EF EF
EF
EF
EF
EF
EF
EF
SVP
SVP
SVP
SVP SVP SVP
PRD
ORD
PRD
ORD
GUDS DS
SVP
SVP
ORD
PRD
ORD
PRD
SVP
SVP
SVP
ORD
PRD
PP
PP
PP
PP
EF
PP
OS
RTU
OS
OS
OS
OS
OS
OS
EJ
EJ
EJ
EJ
PRD
EF
EJ
EJ
SVP
SVP
SVP
SVP
EF
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
MATCH LINE B
MATCH LINE D
34'-3"±
18'±
45'±
23'-5"±40'-4"±4'-4"±
16'-1"± 50'-5"±
5'-8"±
20'-3"±
15'-4"±
TYP.
TYP.
TYP.
TYP.
TYP.
18'±
42'-9"±
23'-3"±
24'-8"±
9'-11"±
12'-6"±
23'±
TYP.
A-502
TYP.
A-503
TYP.
A-501
TYP.
A-502
TYP.
A-503
TYP.
A-503
TYP.
A-501
TYP.
HIGH
A-501
TYP.
LOW
A-501
TYP.
LOW
(TO EDGE OF ROOF BEYOND)
(TO EDGE OF ROOF BEYOND)
70'-6"±
(N.I.C)
(N.I.C)
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-111
BUILDING 1 ENLARGED
ROOF PLAN NEW - D
N
SCALE: 1/8" = 1'-0"
BUILDING 1 ENLARGED ROOF PLAN NEW - D
1 FURNISH AND INSTALL NEW INSULATION, COVER
BOARD, ROOFING MEMBRANE, AND METAL
FLASHINGS ACCORDING TO SPECIFICATIONS.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK, 061000 ROUGH CARPENTRY, 072200 ROOF
BOARD INSULATION, 075216.11 COLD ADHESIVE
STYRENE-BUTADIENE-STYRENE MODIFIED
BITUMINOUS MEMBRANE ROOFING, 076000 FLASHING
AND SHEET METAL, 077100 ROOF SPECIALTIES,
077200 ROOF ACCESSORIES, AND 221400 FACILITY
STORM DRAINAGE
PROPERLY REINSTALL AND COMMISSION EXISTING
LIGHTNING PROTECTION. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION
3 FURNISH AND INSTALL NEW LADDER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 055000 METAL FABRICATIONS
4 FURNISH AND INSTALL NEW SEALANT AT STONE
COPING JOINT.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 079200 JOINT SEALANTS
5 FURNISH AND INSTALL NEW EXPANSION JOINT
BELLOW SYSTEM.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 077100 ROOF SPECIALITIES
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
6 FURNISH AND INSTALL NEW SCUPPER LINER.
SEE NOTES ON A-101 FOR SIZING REQUIREMENTS
TAPERED INSULATION
PS PS PS PS
PS
P S
P S
P S
OS
PP
EF
PRD
SVP
SVP SVP
PP
SVP
SVP
EF
SVP
EF
PP PP PP
EF
PP
PP
PP
EF
EF
EF
PP
PP PP PP PP
PP PP
PP
PP
PP
PP
ROOF A1
ROOF A2
104'-3"±
65'-11"±
TYP.
TYP.
RTU RTU RTU RTU
TYP.
A-503
TYP.
A-503
TYP.
A-502
TYP.
A-502
TYP.
A-503
TYP.
A-501
TYP.
A-503
TYP.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-113
BUILDING 12
ROOF PLAN NEW
N
SCALE: 1/4" = 1'-0"
BUILDING 12 ROOF PLAN NEW
1 FURNISH AND INSTALL NEW INSULATION, COVER
BOARD, ROOFING MEMBRANE, AND METAL
FLASHINGS ACCORDING TO SPECIFICATIONS.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK, 061000 ROUGH CARPENTRY, 072200 ROOF
BOARD INSULATION, 075216.11 COLD ADHESIVE
STYRENE-BUTADIENE-STYRENE MODIFIED
BITUMINOUS MEMBRANE ROOFING, 076000 FLASHING
AND SHEET METAL, 077100 ROOF SPECIALTIES,
077200 ROOF ACCESSORIES, AND 221400 FACILITY
STORM DRAINAGE
PROPERLY REINSTALL AND COMMISSION EXISTING
LIGHTNING PROTECTION. REFER TO SPECIFICATION
011100 SUMMARY OF WORK AND 264100 FACILITY
LIGHTING PROTECTION
3 FURNISH AND INSTALL NEW LADDER.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 055000 METAL FABRICATIONS
4 FURNISH AND INSTALL NEW METAL COPING.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 076000 FLASHING AND SHEET METAL
5 FURNISH AND INSTALL NEW EXPANSION JOINT
BELLOW SYSTEM.
REFER TO SPECIFICATION 011100 SUMMARY OF
WORK AND 077100 ROOF SPECIALITIES
ROOFTOP UNIT
ROOF
OUTLINE/PARAPET
GUTTER (GU)
VENT THRU ROOF
(VTR)
PRIMARY ROOF
DRAIN (PRD)
PITCH POCKET (PP)
ROOF OUTLINE/
GRAVE-STOP FASCIA
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
EXHAUST FAN (EF)
SKYLIGHT (S)
S
ROOF ACCESS -
LADDER
STRUCTURAL
RIDGE/HIP
VALLEY
LEGEND
HOT VENT STACK
(HVS)
OVERFLOW SCUPPER
OS
SOIL VENT PIPE
(SVP)
FALL PROTECTION
DEVICE (FPD)
DOWNSPOUT (DS)
OVERFLOW ROOF
DRAIN (ORD)
SATELLITESA
EXPANSION JOINT
EJ
ABANDONED CURB
6 ROOF AREAS A1 & A2: MODIFY EXISTING SCUPPER
OPENING TO RECEIVE A MINIMUM 4" x 10" SCUPPER
LINER
7 ALL ROOF DRAIN LEADERS TO BE A MINIMUM 3"Ø
(DIAMETER)
TAPERED INSULATION
ROOF 8B
ROOF 1F
ROOF 1E
ROOF 10A (N.I.C)
ROOF 11A (N.I.C)
ROOF 2C
ROOF 2B
ROOF 3C
ROOF 1B
ROOF 2D.1
ROOF 1C
ROOF 9A
ROOF 7C
ROOF 1G
ROOF 2D.2
ROOF 9C
(N.I.C)
ROOF 1G.1
ROOF 1G.3
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
37'±1'-9"±
57'-8"±
19'-8"± 6'-5"± 14'-2"±
3'-8"±
15'± 42'-9"±
20'±
38'-8"±
19'-4"±
38'±
11'-6"±
33'-4"±
11'-7"±
23'-8"±
16'-3"±
14'-1"±
21'-8"±
46'-7"±
31'-3"±
39'-4"±
40'-5"±
34'-11"±
25'-1"± 30'-3"±
56'-3"±
ROOF 9B
8'
8'
8'
8'
8'
8'
8'
8'
4'
4'
4'
4'
8'
8'
8'
8'
3 3
4'
4'
4'
2 2
4' 4'
3 3
3 3
2 2
4'
4'
33 2
2 21
8'
4'
8'
8'
8'
3 3
4'
4'
8'
4' 4'
4'
4' 4'
4'
4' 4'
4'
3 3
12' 12'
12'
(TO EDGE OF ROOF BEYOND)
17'-5"±
25'-1"± 42'-4"±
41'-7"± 30'-1"±6'±
36'-7"± 36'-5"±
45'-2"±
56'-9"±
26'-1"±
44'-11"± 41'-4"±
27'-9"±
(TO EDGE
OF ROOF
BEYOND)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-114
BUILDING 1 WIND ZONE
ENLARGED ROOF PLAN - A
N
SCALE: 1/8" = 1'-0"
BUILDING 1 WIND ZONE ENLARGED ROOF PLAN NEW - A
LEGEND
ROOF AREA 1B, 1C, 1G, 1G.1, 1G.3
WIND ZONE NO. 1: 18.83 PSF
WIND ZONE NO. 2: 31.60 PSF
WIND ZONE NO. 3: 47.56 PSF
WIND ZONE NO. 1
WIND ZONE NO. 3
WIND ZONE NO. 2
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
ROOF AREA 1E, 1F
WIND ZONE NO. 1: 19.25 PSF
WIND ZONE NO. 2: 32.31 PSF
WIND ZONE NO. 3: 48.63 PSF
ROOF AREA 2B, 2C, 2D.1, 2D.2
WIND ZONE NO. 1: 20.93 PSF
WIND ZONE NO. 2: 35.13 PSF
WIND ZONE NO. 3: 52.87 PSF
ROOF AREA 3C
WIND ZONE NO. 1: 22.55 PSF
WIND ZONE NO. 2: 37.84 PSF
WIND ZONE NO. 3: 56.95 PSF
ROOF AREA 7B
WIND ZONE NO. 1: 36.33 PSF
WIND ZONE NO. 2: 57.02 PSF
WIND ZONE NO. 3: 77.72 PSF
ROOF AREA 7C
WIND ZONE NO. 1: 36.24 PSF
WIND ZONE NO. 2: 56.89 PSF
WIND ZONE NO. 3: 77.53 PSF
ROOF AREA 8B
WIND ZONE NO. 1: 37.19 PSF
WIND ZONE NO. 2: 58.37 PSF
WIND ZONE NO. 3: 79.56 PSF
ROOF AREA 8C
WIND ZONE NO. 1: 37.38 PSF
WIND ZONE NO. 2: 58.67 PSF
WIND ZONE NO. 3: 79.96 PSF
ROOF AREA 9A
WIND ZONE NO. 1: 38.50 PSF
WIND ZONE NO. 2: 60.44 PSF
WIND ZONE NO. 3: 82.37 PSF
ROOF AREA 9B
WIND ZONE NO. 1: 39.47 PSF
WIND ZONE NO. 2: 61.95 PSF
WIND ZONE NO. 3: 84.44 PSF
ROOF AREA 9B
WIND ZONE NO. 1: 39.47 PSF
WIND ZONE NO. 2: 61.95 PSF
WIND ZONE NO. 3: 84.44 PSF
ROOF 3A
ROOF 3E
ROOF 2D
ROOF 3D
ROOF 2E
ROOF 4E
ROOF X1
ROOF O
ROOF S
(SMOKE HOUSE)
R O
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
B
M A
T C
H
L
I N
E
A
MATCH LINE B
MATCH LINE D
26'±
41'-3"±
16'±
12'-7"±
9'-1"±
99'-2"±
9'-9"±
4'±
16'-1"±
37'-4"±
30'-3"±
56'-3"±
8'-3"±
31'-10"±
35'-11"± 40'-1"±
45'-2"±
8'±
13'-6"±
4'
4'
4'
3 3
2 2
4'
4'
4' 4'
4'
8'
8'
4'
4'
4'
4'
8'
8'
8'
8'8'
8'
8'
8'
3 3
4' 4'
4'
4'
102'-3"±
17'±
(TO EDGE
OF ROOF
BEYOND)
(TO EDGE OF ROOF BEYOND)
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-115
BUILDING 1 WIND ZONE
ENLARGED ROOF PLAN - B
N
SCALE: 1/8" = 1'-0"
BUILDING 1 WIND ZONE ENLARGED ROOF PLAN NEW - B
LEGEND
WIND ZONE NO. 1
WIND ZONE NO. 3
WIND ZONE NO. 2
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
ROOF AREA 1G.2, 2E
WIND ZONE NO. 1: 21.14 PSF
WIND ZONE NO. 2: 35.48 PSF
WIND ZONE NO. 3: 53.40 PSF
ROOF AREA 2D
WIND ZONE NO. 1: 20.93 PSF
WIND ZONE NO. 2: 35.13 PSF
WIND ZONE NO. 3: 52.87 PSF
ROOF AREA 3A, 3E
WIND ZONE NO. 1: 22.60 PSF
WIND ZONE NO. 2: 37.93 PSF
WIND ZONE NO. 3: 57.08 PSF
ROOF AREA 3D
WIND ZONE NO. 1: 24.40 PSF
WIND ZONE NO. 2: 40.94 PSF
WIND ZONE NO. 3: 61.61 PSF
ROOF AREA 4E
WIND ZONE NO. 1: 25.21 PSF
WIND ZONE NO. 2: 42.31 PSF
WIND ZONE NO. 3: 63.68 PSF
ROOF AREA 6B
WIND ZONE NO. 1: 36.46 PSF
WIND ZONE NO. 2: 57.23 PSF
WIND ZONE NO. 3: 78.01 PSF
ROOF AREA 8D
WIND ZONE NO. 1: 38.47 PSF
WIND ZONE NO. 2: 60.38 PSF
WIND ZONE NO. 3: 82.30 PSF
ROOF AREA O, X1
WIND ZONE NO. 1: 18.83 PSF
WIND ZONE NO. 2: 31.60 PSF
WIND ZONE NO. 3: 47.56 PSF
ROOF AREA S
WIND ZONE NO. 1: 19.09 PSF
WIND ZONE NO. 2: 32.03 PSF
WIND ZONE NO. 3: 48.21 PSF
ROOF AREA S
WIND ZONE NO. 1: 19.09 PSF
WIND ZONE NO. 2: 32.03 PSF
WIND ZONE NO. 3: 48.21 PSF
ROOF BG
(N.I.C)
ROOF 2F(KITCHEN)
ROOF 4B
ROOF 4A.1
ROOF 4A.2
ROOF 4A
ROOF 5A
ROOF BD.1
ROOF BD.2
ROOF 4C
ROOF BA
(EMS DOCK)
ROOF BF
ROOF BC
ROOF BB
(N.I.C)
(N.I.C)
H H H
H H H
H
H
H
BUILDING 1 KEY PLAN
A B
C D
MATCH LINE A
MATCH LINE C
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
59'-2"±
11'-7"±
37'-4"±
23'-8"±
35'-6"±
37'-8"±
40'-1"±
11'-2"±
40'-4"±
46'-2"±
37'-9"±
36'-2"±
5'-5"±
4'-7"±
34'-10"±
20'-3"±
29'-7"±
13'±
7'-3"±
2'-7"± 10'-5"±
5'-2"±
5'-7"±
11'-6"±
10'-9"±
15'-4"±
25'-2"±
ROOF 9A
8'
8'
8'
8'
8'
8'
8'
4'
4'
4'
8' 8'
8'
4'
4'
4'
2 3
3 2
4'
4'
8' 8'
8'
12'
12'
4'
4'
4'
4'
4'
4'
3 3
3 3
4'
4'
(TO EDGE OF ROOF BEYOND)
44'-9"±
96'-2"±
30'-8"±
19'-10"±
27'-7"±
7'-3"±
59'-3"±
53'-9"±
(N.I.C)
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-116
BUILDING 1 WIND ZONE
ENLARGED ROOF PLAN - C
N
SCALE: 1/8" = 1'-0"
BUILDING 1 WIND ZONE ENLARGED ROOF PLAN NEW - C
LEGEND
WIND ZONE NO. 1
WIND ZONE NO. 3
WIND ZONE NO. 2
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
ROOF AREA 2F
WIND ZONE NO. 1: 22.90 PSF
WIND ZONE NO. 2: 38.43 PSF
WIND ZONE NO. 3: 57.84 PSF
ROOF AREA 4A
WIND ZONE NO. 1: 34.34 PSF
WIND ZONE NO. 2: 53.89 PSF
WIND ZONE NO. 3: 73.45 PSF
ROOF AREA 4A.1, 5A
WIND ZONE NO. 1: 35.48 PSF
WIND ZONE NO. 2: 55.70 PSF
WIND ZONE NO. 3: 75.91 PSF
ROOF AREA 4A.2
WIND ZONE NO. 1: 34.98 PSF
WIND ZONE NO. 2: 54.91 PSF
WIND ZONE NO. 3: 74.83 PSF
ROOF AREA 4B
WIND ZONE NO. 1: 33.88 PSF
WIND ZONE NO. 2: 53.18 PSF
WIND ZONE NO. 3: 72.47 PSF
ROOF AREA 4C
WIND ZONE NO. 1: 25.04 PSF
WIND ZONE NO. 2: 42.01 PSF
WIND ZONE NO. 3: 63.22 PSF
ROOF AREA 7A
WIND ZONE NO. 1: 37.48 PSF
WIND ZONE NO. 2: 58.82 PSF
WIND ZONE NO. 3: 80.17 PSF
ROOF AREA 8A
WIND ZONE NO. 1: 37.19 PSF
WIND ZONE NO. 2: 58.37 PSF
WIND ZONE NO. 3: 79.56 PSF
ROOF AREA BD.1, BD.2
WIND ZONE NO. 1: 19.66 PSF
WIND ZONE NO. 2: 32.99 PSF
WIND ZONE NO. 3: 49.65 PSF
ROOF AREA 9A
WIND ZONE NO. 1: 38.50 PSF
WIND ZONE NO. 2: 60.44 PSF
WIND ZONE NO. 3: 82.37 PSF
ROOF AREA BA, BB, BC
WIND ZONE NO. 1: 18.83 PSF
WIND ZONE NO. 2: 31.60 PSF
WIND ZONE NO. 3: 47.56 PSF
ROOF 1A
ROOF 5B
ROOF 5C
ROOF 5C.1
ROOF 4D
(N.I.C)
H
H
6'-0"
BUILDING 1 KEY PLAN
A B
C D
M A
T C
H
L
I N
E
D
M A
T C
H
L
I N
E
C
MATCH LINE B
MATCH LINE D
34'-3"±
18'±
45'±
23'-5"±40'-4"±4'-4"±
16'-1"± 50'-5"±
5'-8"±
20'-3"±
15'-4"±
20'±
42'-9"±
23'-3"±
24'-8"±
9'-11"±
12'-6"±
23'±
4'
4'
4'
8'
8'
8'
8'8'
8'
8'
8'
8'
8'
16'
16'
3 2
8'
8'
8'
(TO EDGE OF ROOF BEYOND)
(TO EDGE OF ROOF BEYOND)
70'-6"±
(N.I.C)
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-117
BUILDING 1 WIND ZONE
ENLARGED ROOF PLAN - D
N
SCALE: 1/8" = 1'-0"
BUILDING 1WIND ZONE ENLARGED ROOF PLAN NEW - D
LEGEND
WIND ZONE NO. 1
WIND ZONE NO. 3
WIND ZONE NO. 2
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
ROOF AREA 1A
WIND ZONE NO. 1: 21.64 PSF
WIND ZONE NO. 2: 36.31 PSF
WIND ZONE NO. 3: 54.64 PSF
ROOF AREA 2A
WIND ZONE NO. 1: 22.51 PSF
WIND ZONE NO. 2: 37.77 PSF
WIND ZONE NO. 3: 56.84 PSF
ROOF AREA 3B
WIND ZONE NO. 1: 24.88 PSF
WIND ZONE NO. 2: 41.75 PSF
WIND ZONE NO. 3: 62.83 PSF
ROOF AREA 4D
WIND ZONE NO. 1: 34.34 PSF
WIND ZONE NO. 2: 53.89 PSF
WIND ZONE NO. 3: 73.45 PSF
ROOF AREA 5B, 5C
WIND ZONE NO. 1: 35.48 PSF
WIND ZONE NO. 2: 55.70 PSF
WIND ZONE NO. 3: 75.91 PSF
ROOF AREA 5C.1
WIND ZONE NO. 1: 35.08 PSF
WIND ZONE NO. 2: 55.07 PSF
WIND ZONE NO. 3: 75.05 PSF
ROOF A1
ROOF A2
104'-3"±
65'-11"±
3 3
3 3
4'
4'
4'
3 3
3 3
4'
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
REPLACE ROOFS,
PHASE I
603-18-301
ROBLEY REX VA MEDICAL CENTER
LOUISVILLE KY 40206
18-392
100% CONSTRUCTION DOCUMENTS
Engineer of Record:
Raymond
Engineering-Georgia 1224
Royal Drive, Suite 100
Conyers, GA 30094
770-483-9592 Raymond
Ramos, PE, RRC
.\Logo-RaymondEngineering-CMYK.jpg
ARF2021.02.12 JMC
T-684
C:\Users\jonathan.clark\Desktop\Stamp.png
A-119
BUILDING 12
WIND ZONE ROOF PLAN
N
SCALE: 1/4" = 1'-0"
BUILDING 12 WIND ZONE ROOF PLAN NEW
LEGEND
WIND ZONE NO. 1
WIND ZONE NO. 3
WIND ZONE NO. 2
ROOF AREA NOT-IN-
CONTRACT (N.I.C.)
ROOF AREA A1, A2
WIND ZONE NO. 1: 19.10 PSF
WIND ZONE NO. 2: 32.03 PSF
WIND ZONE NO. 3: 48.21 PSF
B E
L O
W
B
L O
C K
I N
G
M
I N
I M
U M
SHEET-METAL PARAPET CAP
SLOPED TO DRAIN TO ROOF
CONTINUOUS WEATHERPROOF
MEMBRANE ON TOP OF WALL
TURNED DOWN BOTH SIDES
CONTINUOUS SHIM
WOOD NAILER ATTACHED
TO SUBSTRATE
FASTENERS APPROX. 8" O.C.
MEMBRANE FLASHING SHEET
ADHERED TO BACKER, MOP- OR
COLD-APPLIED (FOR ROOF SYSTEMS
WITH FACTORY-APPLIED GRANULE
SURFACING, THE MULTIPLE-PLY
MEMBRANE FLASHING CAN BE
INSTALLED BETWEEN THE BASE PLY
AND GRANULE-SURFACED SHEET)
OPTIONAL: EXTENDED FIELD
PLIES ABOVE TOP OF CANT
MULTIPLE-PLY MODIFIED
BITUMEN ROOF MEMBRANE
CANT
COVER-BOARD INSULATION
THERMAL INSULATION
ROOF DECK
M
I N
I M
U M
F L A
S H
I N
G
H
E I G
H T
CONTINUOUS CLEAT
BACKER
GASKETED FASTENERS
B E
L O
W
B
L O
C K
I N
G
M
I N
I M
U M
SHEET-METAL GRAVEL STOP
SET IN COMPATIBLE ROOF
CEMENT, PRIME FLANGE
BEFORE STRIPPING
OPTIONAL: COMPATIBLE
SEALANT AT JUNCTION OF
MEMBRANE AND EDGE
METAL
FASTENERS AT APPROX. 3''
to 6'' O.C., STAGGERED
MODIFIED BITUMEN
MEMBRANE STRIPPING SHEET
(FOR ROOF SYSTEMS WITH
FACTORY-APPLIED GRANULE
SURFACING, THE GRAVEL-
STOP FLANGE AND
MEMBRANE STRIPPING CAN
BE INSTALLED BETWEEN THE
BASE PLY AND GRANULE-
SURFACED SHEET)
MULTIPLE-PLY MODIFIED
BITUMEN ROOF MEMBRANE
COVER-BOARD INSULATION
THERMAL INSULATION
ROOF DECK
ONE PLY OR SEPARATE
MEMBRANE SHEET EXTENDED
BELOW BLOCKING
CONTINUOUS CLEAT
2 X 6 MIN. WOOD NAILER
ATTACHED TO SUBSTRATE --
OVERALL THICKNESS TO
MATCH INSULATION
SMOOTH CONCRETE
INSTALL APPROPRIATE SEALANT
AND TOOL TO FACILITATE WATER
RUNOFF
OPTIONAL: COMPRESSIBLE
ELASTOMERIC SEALANT OR TAPE
TO SPAN IRREGULARITIES
CONCRETE FASTENERS
SEAL TOP OF FLASHING WITH A
COMPATIBLE VERTICAL-GRADE ROOF
CEMENT AND REINFORCEMENT
SHEET-METAL COUNTERFLASHING
FASTENERS APPROX. 8'' O.C.
OPTIONAL: EXTENDED FIELD PLIES
ABOVE TOP OF CANT (NOT SHOWN FOR
CLARITY)
MEMBRANE FLASHING SHEET
ADHERED TO BACKER (FOR ROOF
SYSTEMS WITH FACTORY-APPLIED
GRANULE SURFACING, THE
MULTIPLE-PLY MEMBRANE FLASHING
CAN BE INSTALLED BETWEEN THE
BASE PLY AND GRANULE-SURFACED
SHEET)
MULTIPLE-PLY MODIFIED BITUMEN
ROOF MEMBRANE
COVER-BOARD INSULATION
CANT
THERMAL INSULATION
ROOF DECK
M
I N
I M
U M
F L A
S H
I N
G
H
E I G
H T
BACKER
EXISTING SHEET-METAL REGLET
FASTENERS
OPTIONAL: MEMBRANE SHEET CLOSURE
SECURED AND ADHERED TO WALL
REMOVABLE SHEET-METAL
COUNTERFLASHING
OPTIONAL: EXTENDED FLASHING
FASTENERS APPROX. 8'' O.C.
OPTIONAL: EXTENDED FIELD PLIES
ABOVE TOP OF CANT STRIP (NOT
SHOWN FOR CLARITY)
FLEXIBLE VAPOR RETARDER WITH
COMPRESSIBLE INSULATION
MEMBRANE FLASHING SHEET ADHERED TO
BACKER, MOP- OR COLD-APPLIED. COVER
TOP OF BASE FLASHING WITH VAPOR
RETARDER. (FOR ROOF SYSTEMS WITH
FACTORY-APPLIED GRANULE SURFACING,
THE MULTIPLE-PLY MEMBRANE FLASHING
CAN BE INSTALLED BETWEEN THE BASE PLY
AND GRANULE-SURFACED SHEET)
MULTIPLE-PLY MODIFIED BITUMEN
ROOF MEMBRANE
COVER-BOARD INSULATION
THERMAL INSULATION
ROOF DECK
CANT
F L A
S H
I N
G
H
E I G
H T
M
I N
I M
U M
MASONRY WALL AND FLASHING
BACKER
2 X 6 MIN. WOOD NAILER ATTACHED TO
SUBSTRATE -- OVERALL THICKNESS TO
MATCH INSULATION
EXISTING SHEET-METAL REGLET
FASTENERS
REMOVABLE SHEET-METAL
COUNTERFLASHING
SEAL TOP OF FLASHING WITH A
COMPATIBLE VERTICAL-GRADE
ROOF CEMENT AND
REINFORCEMENT
FASTENERS APPROX. 8'' O.C.
NONCOMBUSTIBLE SURFACE.
PRIME SURFACE AS REQUIRED
OPTIONAL: EXTENDED FIELD
PLIES ABOVE TOP OF CANT
CANT
MEMBRANE FLASHING SHEET
ADHERED TO BACKER (FOR
ROOF SYSTEMS WITH
FACTORY-APPLIED GRANULE
SURFACING, THE MULTIPLE-PLY
MEMBRANE FLASHING CAN BE
INSTALLED BETWEEN THE BASE
PLY AND GRANULE-SURFACED
SHEET)
MULTIPLE-PLY MODIFIED
BITUMEN ROOF MEMBRANE
COVER-BOARD INSULATION
T…