SALIENT CHARACTERISTICS

Resilient Sheet Flooring

Patcraft COLLECTION Holistic

STYLE NUMBER I422V

Colors: Echo 00120 & Sheer 00535 CONSTRUCTION Commercial Homogeneous Sheet OVERALL THICKNESS 0.079 inches (2 mm)

REFERENCE SPECIFICATION ASTM 1913

FINISH ExoGuard™ INSTALLATION TYPE Dry Back INSTALLATION Glue Down RECOMMENDED ADHESIVE S150 SPRAY ADHS, 4151 or LOKWORX+ RESILI

Packaging ROLL SIZE 78.94 inches W x 65.94 ft L, 2 m W x 20.1 m L;

47.84 sq yds/roll 40 sq m/roll

PIECES /BOX 12

AREA /BOX 47.84 sq yds, 40 sq m WEIGHT /ROLL 284 lbs, 128.8 kg

Performance Testing STATIC LOAD / ASTM F970 Passes (Modi_ed), *2000 lbs FLEXIBILITY / ASTM F137 Passes RESIDUAL INDENTATION / ASTM F1914 Passes RESISTANCE TO CHEMICALS / ASTM F925 Passes RADIANT PANEL / ASTM E648 Passes, Class I SMOKE DENSITY / ASTM E662 Passes SLIP RESISTANCE / ASTM D2047 >0.6, meets the recommended static coef_cient of friction for ADA walking surfaces and accessible routes

Warranty 15 Year Limited Commercial.

Commercial Limited Underbed Bond Shaw 4100, S150 Or Shaw 4151.

Please visit patcraft.com for the most current warranty information.

Environmental FloorScore® Certified

See Patcraft website for additional information.

Adhesive

SHAW 4151 UNIVERSAL PERFORMANCE ADHESIVE

DESCRIPTION

Shaw 4151 is an enhanced formulated universal performance adhesive designed for multiple backing systems, including resilient (sheet/lvt/lvp), carpet tile and non-patterned EPBL.

APPROVED SUBSTRATES

For interior use only.

Wood Association approved wood underlayment and sub|ooring. See Resilient Wood Substrate Information Sound and properly prepared concrete (on, above or below grade), metal, wood {berglass and terrazzo.

Existing resilient products should be over 1 year old, secure and fully adhered with a full spread of adhesive. Remove all waxes and polishes from the existing |oor before installation.

SUBSTRATE TESTING

RH - 99% (ASTM F-2170), provided the site is absent of hydrostatic pressure.

CaCl / MVER - 10 lbs (ASTM F-1869) pH - 11 (ASTM F-710) For on-grade / below grade installations, CaCl, RH and pH testing are required.

For above grade installations, RH testing is required.

For older slabs or slabs with a prior history of moisture related issues, Shaw Technical Support recommends moisture mitigation in the form of a 2-part epoxy system, such as MoistureTEK.

For newer slabs with an intact moisture retarder, initial moisture levels should recede over time.

SUBSTRATE PREPARATION

Substrate must be structurally sound, clean, level and dry.

Substrate must be free of dust, dirt, oil, grease, paint, curing agents, concrete sealers, adhesives, loosely bonded toppings, loose particles and any other substance or condition that may prevent or reduce adhesion.

Do not use over substrates containing asbestos or active cutback adhesive.

Fill depressions or cracks with a cementitious patching / leveling compound that meet or exceed Shaw Industries maximum moisture level and pH requirements. Use of gypsum-based patching and/or leveling compounds which contain Portland or high alumina cement and meet or exceed the compressive strength of 3,000 psi are acceptable.

Installation site must be acclimated with HVAC in operation or the temperature must be controlled between 65-95 O F (18- 35 O C) and the ambient relative humidity controlled between 30-65% before, during and permanently after the installation.

Do not use over chemically abated substrates.

APPLICATION INSTRUCTIONS AND SPREAD RATES

Read and follow the product specific installation guidelines for layout, design and any special instructions for installation.

Spread adhesive using the recommended trowel.

Spread adhesive evenly over substrate, keeping the trowel at a 45° angle to the substrate.

After installation of floor covering, roll floor covering with a 75 – 100 lb roller.

NOTE: For vinyl, back roll the adhesive with a short nap roller to reduce telegraphing of adhesive ridges.

Note: Coverage rate, flash time and working time may vary based on temperature, humidity, substrate porosity, jobsite conditions and application practices. Coverages are estimates only. Actual jobsite coverages may vary according to substrate conditions, type of trowel used and setting practices.

Trowel dimensions are depth/width/space. Areas with lower than normal relative humidity will result in a reduced working time.

PRODUCT CHARACTERISTICS

ENVIRONMENTAL

California South Coast Air Quality Management District Rule 1168 California Department of Public Health Section 01350 Greenguard / Greenguard Gold - #216283-410/216283-420

WARRANTY

This product is covered by a 10 year limited warranty and under bed warranty when used with specific products. For more detailed information on this limited warranty, please see contact information at the bottom of this page.