S02 Attachment II - Drawing Package.pdf
PDF 7 MB Posted
- Attached to
- Z1DA--36C24621|Building 27|59020104
- Solicitation number
- 36C24622B0007
About this file
This is a solicitation for structural repairs and upgrades to Building 27 at the Veterans Affairs Medical Center in Hampton, Virginia. The solicitation number is 36C24622B0007 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6.
Required work includes repairs to wood framing members, roofing, masonry, concrete, and steel elements. Specific repairs include replacing deteriorated wood framing with pressure treated southern yellow pine, repointing brick walls, repairing concrete spalls and columns, and repairing steel beams. The project also involves installing new wood stairs and guardrails. The response due date is not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0004.docx | DOCX document | |
| S07-Abstract of Offers-Building 27 36C24622B0007 FE.pdf | ||
| 36C24622B0007 0004.docx | DOCX document | |
| S07-Abstract of Offers-Building 27 36C24622B0007 PG 2.pdf | ||
| Copy of Building 27 Consolidated Questions COR - TMM - Response.xlsx | XLSX spreadsheet | |
| Description.docx | DOCX document | |
| 36C24622B0007 0003.docx | DOCX document | |
| 36C24622B0007 0002.docx | DOCX document | |
| S06 590-20-104 Bldg 27 1 Apr 2022 Site Visit Attendees Sign In Sheet.pdf | ||
| S02 Attachment IV - Bid Item Cost Breakdown WS.xlsx | XLSX spreadsheet | |
| S02 Attachment I - Specification Package.pdf | ||
| 36C24622B0007_1.docx | DOCX document | |
| S02 Attachment III - WD VA20210022 25 Feb 2022.pdf | ||
| S02 Attachment V - Statement of Requirements.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 27 STRUCTURAL
REPAIR / UPGRADE
100% CONSTRUCTION DOCUMENTS
AT VAMC HAMPTON
100 EMANCIPATION DRIVE, HAMPTON, VA 23667
DRAWING TITLE
DWG
NO.
INDEX OF DRAWINGSPROJECT LOCATION
PROJECT SITE
APPROVAL SIGNATURES:
PROJECT # 590-20-104
DRAWING TITLE
DWG
NO.
COVER SHEET
G001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
Project Director
06/04/2021 TS EORevisions: Date:
ARCHITECTURAL LEGEND
MATERIAL LEGEND ARCHITECTURAL GENERAL NOTESGENERAL PROJECT NOTES ARCHITECTURAL ABBREVIATIONS
1.
2.
4.
5.
a.
b.
GENERAL SAFETY NOTES
LEGENDS, ABBREVIATIONS AND
NOTES
G002
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
CONSTRUCTION
LAY-DOWN AREA
-VERIFY WITH VA
BLDG 27
STAGING AREA
OVERALL CAMPUS PLAN
G003
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
ABATEMENT PLANS AND NOTES
AB101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
STAGING PLAN
AS101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
BASEMENT FLOOR PLAN
AE100
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
FIRST FLOOR PLAN
AE101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
REFLECTED CEILING PLAN
AE102
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
ROOF PLAN
AE103
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
ELEVATIONS
AE201
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
DETAILS
AE501
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
BASEMENT DOOR AND FRAME SCHEDULE
DOOR NO.
DOOR FRAME
FIRE
RATING
HDWR
SET
REMARKS
SIZE
TYPE MATL TYPE MATL
DETAIL
W x H THK HEAD JAMB SILL
FIRST FLOOR DOOR AND FRAME SCHEDULE
DOOR NO.
DOOR FRAME
FIRE
RATING
HDWR
SET
REMARKS
SIZE
TYPE MATL TYPE MATL
DETAIL
W x H THK HEAD JAMB SILL
BASEMENT ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME FLOOR BASE
WALLS CEILING
REMARKS
N E S W MATL HEIGHT
FIRST FLOOR ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME FLOOR BASE
WALLS CEILING
REMARKS
N E S W MATL HEIGHT
DOOR AND FINISH SCHEDULES
AE601
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
100%
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
590-20-104
DESIGN CODES
1.01 2018 INTERNATIONAL BUILDING CODE (IBC) AS MODIFIED BY:
A. ANSI/ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
1.02 AMERICAN FOREST & PAPER ASSOCIATION (AF & PA)
A. NDS-2012 NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION WITH 2012
SUPPLEMENT
1.03 AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
A. ANSI/AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
1.04 AMERICAN CONCRETE INSTITUTE (ACI)
A. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
DESIGN LOADS
1.01 DESIGN LOADS ARE AS FOLLOWS:
A. ROOF:
1. DEAD LOADS:
a. SELF WEIGHT OF MATERIALS
2. LIVE LOADS:
a. 20 PSF WITH NO LOAD REDUCTION
3. RAIN LOADS: NOT APPLICABLE.
4. SNOW LOADS: GROUND SNOW LOAD
a. GROUND SNOW LOAD Pg = 10.0 PSF
B. FLOOR:
1. DEAD LOADS:
a. SELF WEIGHT OF MATERIALS
b. ADDITONAL SUPERIMPOSED DEAD LOAD: 15 PSF
2. LIVE LOADS:
a. 100 PSF WITH NO LIVE LOAD REDUCTION. A PARTITION LOAD OF 20 PSF IS NOT REQUIRED
BECAUSE THE FLOOR LIVE LOAD IS 100 PSF.
C. WIND LOADS:
1. ULTIMATE DESIGN WIND SPEED Vult = 117 MPH
2. NOMINAL DESIGN WIND SPEED Vasd = 90.6 MPH
3. IMPORTANCE FACTOR Iw = 1.0
4. RISK CATEGORY II
5. WIND EXPOSURE = B
D. EARTHQUAKE LOADS:
1. GENERAL RISK CATEGORY
a. CATEGORY II
b. SEISMIC IMPORTANCE FACTOR I = 1.0
c. OCCUPANCY CATEGORY = II
d. MAPPED SPECTRAL RESPONSE ACCELERATIONS
1) Ss = 0.091
2) S1= 0.04
e. SITE CLASS = D
f. SPECTRAL RESPONSE COEFFICIENTS (FOR SITE CLASS D)
1) Sds = 0.097
2) Sd1 = 0.064
g. SITE COEFFICIENTS
1) Fa = 1.6
2) Fv = 2.4
h. SEISMIC DESIGN CATEGORY = A E. GROUND SNOW LOAD Pg = 10 PSF aa
2 22
COMPONENTS AND CLADDING SURFACE PRESSURE (PSF)
ZONE LOCATION
POSITIVE ALL ROOF ZONES
POSITIVE ALL WALL ZONES
EDGE
EDGE
CORNER OVERHANG
EDGE OVERHANG
CORNER
EDGE
FIELD
R O
O F
W A
LL
NOTE: THE DESIGN WIND PRESSURE IS ACTING IN EITHER
DIRECTION NORMAL TO THE SURFACE OF THE C&C
MATERIALS. PRESSURE SHALL NOT BE LESS THAN 10 PSF.
At=10SF At=20SF At=50SF At=100SF
-63.1 -58.9 -53.4 -49.2
-83.2 -77.8 -70.8 -60.1
-113.4 -102.7 -88.5 -77.8
-77.1 -70.0 -60.6 -53.5
-107.3 -94.8 -78.3 -65.9
-39.2 -37.6 -35.5 -33.9
-48.3 -45.1 -40.8 -37.6
+36.2 +34.6 +32.5 +30.9 a = 6' - 6"
+16.0
DEMOLITION AND REMOVAL:
1.01 GENERAL
A. PERFORM ALL DEMOLITION WORK INCLUDING REMOVAL, TRANSPORT, AND DISPOSAL PER ALL
FEDERAL, STATE AND LOCAL RULES AND REGULATIONS.
1.02 EXISTING CONDITIONS
A. BEFORE BEGINNING ANY DEMOLITION WORK, SURVEY THE SITE AND EXAMINE THE
DRAWINGS AND SPECIFICATIONS TO DETERMINE THE EXTENT OF THE WORK.
PHOTOGRAPH EXISTING CONDITIONS AND RECORD EXISTING ELEVATIONS OF FINISH FLOORS
ETC. RECORD LOCATION AND EXTENT OF EXISTING CRACKS AND OTHER DAMAGE. PRIOR TO
STARTING WORK SUBMIT EXISTING CONDITION PHOTOS AND RECORDS TO THE OWNER.
1.03 DUST, DEBRIS AND NOISE CONTROL
A. CONFINE NOISE AND DUST TO IMMEDIATE WORK AREA.
B. CONTRACTOR SHALL REMOVE AND DISPOSE OFF-SITE ALL MATERIALS INDICATED TO BE
DEMOLISHED AND REMOVED, RUBBISH AND DEBRIS DAILY INCLUDING DUST AND DIRT.
1.04 TRAFFIC CONTROL
A. WHERE PEDESTRIAN AND DRIVER SAFETY IS ENDANGERED IN THE AREA OF THE WORK, USE
BARRICADES ANCHORED IN A MANNER TO PREVENT DISPLACEMENT BY WIND.
1.05 ITEMS TO REMAIN IN PLACE
A. TAKE PRECAUTIONS TO AVOID DAMAGE TO EXISTING ITEMS TO REMAIN IN PLACE, TO BE
REUSED OR TO REMAIN THE PROPERTY OF THE OWNER.
B. DO NOT DISTURB EXISTING CONSTRUCTION BEYOND THE EXTENT INDICATED OR
NECESSARY FOR INSTALLATION OF THE NEW WORK.
C. PROTECT NEW WORK FROM DAMAGE AS A RESULT OF SUBSEQUENT WORK.
D. DO NOT OVERLOAD EXISTING STRUCTURAL ELEMENTS, PAVEMENT, FOUNDATIONS, OR WORK TO
REMAIN.
E. INCREASE STRUCTURAL SUPPORT OR ADD NEW SUPPORTS AS MAY BE REQUIRED AS A RESULT
OF DEMOLITION WORK INCLUDING BUT NOT LIMITED TO CUTTING, REMOVAL, AND
DECONSTRUCTION.
F. PROVIDE NEW SUPPORTS AND REINFORCEMENT FOR EXISTING CONSTRUCTION WEAKENED BY
DEMOLITION, DECONSTRUCTION, OR REMOVAL WORK.
G. PROVIDE TEMPORARY SHORING AND BRACING FOR SUPPORT OF BUILDING COMPONENTS TO
PREVENT SETTLEMENT OR OTHER MOVEMENT.
H. COMPLY WITH ALL OSHA REGULATIONS INCLUDING BUT NOT LIMITED TO EXCAVATION SUPPORT.
I. REPAIR OR REPLACE DAMAGED ITEMS AT NO COST TO THE OWNER.
1.06 UTILITIES AND RELATED EQUIPMENT
A. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT
FIRST COORDINATING WITH AND RECEIVING WRITTEN AUTHORIZATION FROM OWNER.
FOUNDATION NOTES
1.01 ALL FOUNDATIONS SHALL BE INSTALLED UNDER THE GUIDANCE OF A REGISTERED
PROFESSIONAL GEOTECHNICAL ENGINEER IN THE STATE OF THE PROJECT. THE
GEOTECHNICAL ENGINEER SHALL GIVE CONSIDERATION TO THE TYPE OF
STRUCTURE AND FOUNDATION LOADS INVOLVED AS WELL AS THE REQUIREMENTS OF
THESE DOCUMENTS. THE GEOTECHNICAL ENGINEER SHALL CONDUCT SUBSURFACE
EXPLORATION TO THE EXTENT NECESSARY TO PROVIDE THIS GUIDANCE. AT A MINIMUM, 2
HAND AUGER BORINGS SHALL BE TAKEN AND THE SLAB-ON-GROUND BASE SHALL BE PROOF-
ROLLED AT EACH APPLICABLE LOCATION.
1.02 THE SAFE BEARING CAPACITY OF THE FOUNDATION SOIL SUPPORTING SPREAD FOOTINGS
SHALL BE A MINIMUM OF 2000 PSF AND SHALL BE TESTED AND APPROVED BY A
PROFESSIONAL GEOTECHNICAL ENGINEER FOR CONFORMATION OF THIS VALUE PRIOR TO
CASTING FOOTING CONCRETE. ALL FOOTINGS SHALL BEAR ON ORIGINAL UNDISTURBED
SOIL OR CONTROLLED FILL.
1.03 STRUCTURAL FILL SHALL CONTAIN NO ORGANIC MATERIAL AND BE APPROVED BY A
GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. STRUCTURAL FILL UNDER SLABS AND
WITHIN 10' - 0" OF THE STRUCTURE FOOTPRINT SHALL BE PLACED IN LIFTS OF THICKNESS
DETERMINED BY THE INDEPENDENT TESTING AGENCY AND COMPACTED TO AT LEAST 95%
OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698. THE
TOP 12" OF SUB-BASE UNDER SLABS ON GROUND SHALL BE COMPACTED TO AT LEAST 98%
OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. AN INDEPENDENT TESTING
LABORATORY SHALL OBSERVE ALL BACKFILL, COMPACTION AND PROOF ROLLING
OPERATIONS..
1.04 UNLESS MORE STRINGENT REQUIREMENTS ARE RECOMMENDED BY THE GEOTECHNICAL
ENGINEER, SLAB-ON-GROUND SHALL BE PLACED ON A 4 INCH GRANULAR BASE, COMPACTED
TO 98% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM
D698. THE BASE FOR THE SLAB-ON-GROUND SHALL BE INSPECTED BY A GEOTECHNICAL
ENGINEER PRIOR TO EACH PLACEMENT OF CONCRETE.
1.05 ALL FOOTINGS AND TURNDOWN SLAB EDGES SHALL PENETRATE TO A MINIMUM DEPTH OF
16 INCHES BELOW TOP OF FINISHED GRADE.
1.06 ISOLATED FOOTINGS SHALL BE A MINIMUM WIDTH OF 18 INCHES AND STRIP
FOOTINGS SHALL HAVE A MINIMUM WIDTH OF 12 INCHES. IN NO EVENT SHALL FOOTINGS
HAVE A WIDTH LESS THAN 12 INCHES.
REINFORCED CONCRETE NOTES:
1.01 CONCRETE DESIGN IS IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE, ACI 318.
1.02 CONCRETE WORK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE FIELD
REFERENCE MANUAL: STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE ACI 301
WITH SELECTED ACI AND ASTM REFERENCES (SP-15).
1.03 ALL CONCRETE SHALL BE NORMAL WEIGHT (145PCF) AND HAVE A MINIMUM 28-DAY
COMPRESSIVE STRENGTH AS FOLLOWS UNLESS NOTED OTHERWISE:
A. f'c = 4,000 PSI .
1.04 FOR CEMENTITIOUS REPAIR MATERIALS SEE SPECIFICATIONS.
1.05 WHEN STRENGTH DATA FROM FIELD EXPERIENCE OR TRIAL MIXTURES ARE NOT AVAILABLE, CONCRETE MIX DESIGN SHALL COMPLY WITH THE FOLLOWING:
A. 4000 PSI NORMAL WEIGHT CONCRETE SHALL BE BASED ON A MAXIMUM AGGREGATE SIZE
OF 1 IN., MAXIMUM WATER/CEMENT RATIO OF .44 FOR NON-AIR-ENTRAINED AND.35 FOR
AIR-ENTRAINED CONCRETE AND A MAXIMUM SLUMP OF 3"
B. THE MAXIMUM SLUMPS SPECIFIED ABOVE SHALL NOT BE EXCEEDED PRIOR TO THE
ADDITION OF WATER REDUCING ADMIXTURES REGARDLESS OF THE EXISTENCE OF TEST
DATA.
C. AIR ENTRAINED CONCRETE SHALL BE USED FOR EXTERIOR EXPOSED CONCRETE IN
ACCORDANCE WITH THE FOLLOWING:
1. MODERATE EXPOSURE BASED ON THE MAXIMUM NOMINAL AGGREGATE SIZE:
a. 3/4": 5 % +/- 1-1/2%
b. 1": 4.5 % +/- 1-1/2%
c. 1-1/2": 4.5 % +/- 1-1/2%
D. NORMAL WEIGHT AGGREGATE SHALL COMPLY WITH ASTM C 33.
E. WHEN PERMITTED, THE WEIGHT OF FLYASH SHALL NOT EXCEED 25% OF THE WEIGHT OF
CEMENT PLUS POZZOLAN.
1.06 CONCRETE SLABS ON GRADE SHALL NOT BE LOADED UNTIL A MINIMUM CONCRETE
STRENGTH OF 1800 PSI HAS BEEN ATTAINED AND THE CONCRETE IS AT LEAST THREE DAYS
OLD. ALL OTHER CONCRETE MEMBERS SHALL NOT BE LOADED UNTIL THE SPECIFIED
CONCRETE DESIGN STRENGTH HAS BEEN ATTAINED.
1.07 ALL STEEL REINFORCEMENT SHALL CONFORM WITH THE FOLLOWING:
A. DEFORMED BARS SHALL CONFORM WITH ASTM A 615 GRADE 60.
B. WELDED WIRE FABRIC (WWF) SHALL CONFORM WITH ASTM A 185, LATEST ADOPTED
EDITION, 65 KSI YIELD AND SHALL BE SUPPLIED IN FLAT SHEETS.
1. SLAB-ON-GRADE WWF SHALL BE SUPPORTED BY PLASTIC COATED CHAIRS OR
CONCRETE BRICK 2" BELOW THE TOP OF SLAB. THE USE OF CLAY BRICKS OR PULLING
UP WWF DURING CONCRETE PLACEMENT IS STRICTLY PROHIBITED. USE A MINIMUM OF
6 X 6 - W1.4 X W1.4.
1.08 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE. SPLICE ONLY AS SHOWN OR
APPROVED. STAGGER SPLICES WHERE POSSIBLE. DOWELS SHALL MATCH SIZE AND
SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH TENSION
SPLICES. UNLESS OTHERWISE NOTED, ALL REINFORCING SHALL BE CONTACT LAP SPLICED
WITH A CLASS B SPLICE IN ACCORDANCE WITH ACI 318-05. FOR BARS WITH A MINIMUM
COVER AND SPACING GREATER THAN 2.0DB AND 3.0DB (DB = BAR DIAMETER) RESPECTIVELY,
THE MINIMUM SPLICE LENGTH, EXPRESSED IN BAR DIAMETERS, SHALL NOT BE LESS THAN
SPECIFIED IN THE REBAR SPLICE SCHEDULE. SPLICE LENGTHS SHALL BE INCREASED BY A
FACTOR OF 1.3 FOR TOP REINFORCEMENT AND WHEN LIGHTWEIGHT CONCRETE IS USED.
LAP WELDED WIRE FABRIC (WWF) ONE SPACE PLUS 2" ON ALL SIDES AT SPLICES.
1.09 ALL DOWELS AND TERMINATING BARS SHALL HAVE A STANDARD 90-DEG HOOK UNO.
1.10 ALL HORIZONTAL REINFORCING SHALL BE CONTINUOUS AROUND CORNERS AND THROUGH
CONSTRUCTION JOINTS UNO.
1.11 CONCRETE COVER AT REINFORCEMENT:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH -3"
B. FORMED CONCRETE EXPOSED TO WEATHER OR EARTH:
1. (#5 AND SMALLER) -1½ ".
2. (#6 TO #18) -2".
C. FORMED CONCRETE NOT EXPOSED TO WEATHER OR EARTH:
1. SLABS, WALL AND JOISTS:
a. # 11 BARS & SMALLER - 3/4".
2. BEAMS AND COLUMNS - 1½"
1.12 CORNER EDGES OF CONCRETE TO BE LEFT EXPOSED TO VIEW SHALL HAVE A CHAMFER OR
RADIUS OR AS INDICATED ON THE DRAWINGS.
1.13 CHECK ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND
EQUIPMENT DRAWINGS FOR EMBEDDED ITEMS AND PENETRATIONS PRIOR TO CONCRETE
PLACEMENT
1.14 ALL CONSTRUCTION JOINTS SHALL HAVE A ROUGH SURFACE AND BE CLEAN PRIOR TO
SUBSEQUENT CONCRETE POUR.
1.15 NO HORIZONTAL CONSTRUCTION JOINTS WILL BE PERMITTED IN SLABS AND FOOTINGS UNO.
1.16 WHERE OPENINGS OCCUR IN SLABS AND WALLS, PLACE THE REINFORCING THAT NORMALLY
OCCURS IN LINE WITH THE OPENING EQUALLY TO EITHER SIDE OF THE OPENING.
1.17 CONCRETE SHALL RECEIVE THE FOLLOWING FINISHES:
A. ALL OTHER CONCRETE - BROOM FINISH
1.18 ALL CONCRETE SHALL BE CONSOLIDATED BY VIBRATION, SPADING, RODDING OR FORKING
SO THAT THE CONCRETE IS THOROUGHLY WORKED AROUND THE REINFORCEMENT, AROUND
EMBEDDED ITEMS, AND INTO CORNERS OF FORMS, ELIMINATING ALL AIR OR STONE
POCKETS WHICH MAY CAUSE HONEYCOMBING, PITTING, OR PLANES OF WEAKNESS. IF
VIBRATORS, OF ADEQUATE SIZE, ARE USED THEY SHALL BE INSERTED AND WITHDRAWN AT
POINTS APPROXIMATELY 18 INCHES APART. AT EACH INSERTION, THE DURATION SHALL BE
SUFFICIENT TO CONSOLIDATE THE CONCRETE BUT NOT SUFFICIENT TO CAUSE
SEGREGATION (GENERALLY FROM 5 TO 15 SECONDS).
1.19 MAINTAIN CONCRETE AFTER PLACEMENT WITH MINIMAL MOISTURE LOSS AT RELATIVELY
CONSTANT TEMPERATURE FOR THE PERIOD NECESSARY FOR HYDRATION OF CEMENT AND
HARDENING OF CONCRETE (NOT LESS THAN 7 DAYS). COMPLY WITH THE REQUIREMENTS OF
ACI 308 - STANDARD PRACTICE FOR CURING CONCRETE; AMERICAN CONCRETE INSTITUTE. A
COMBINATION CURING AND SEALING COMPOUND SHALL BE APPLIED AFTER THE CONCRETE
HAS BEEN FINISHED OR THE FORMS REMOVED. COMPOUND SHALL BE IN ACCORDANCE WITH
ASTM C309, LATEST ADOPTED EDITION, TYPE I, CLASS B. (DESIGN BASIS W.R. MEADOWS
CS-309).
EXISTING CONDITIONS
1.01 AS WITH ANY WORK AFFECTING EXISTING CONSTRUCTION, UNFORESEEN CONDITIONS ARE UNAVOIDABLE WITHOUT DEMOLISHING OTHERWISE SERVICEABLE CONSTRUCTION, DISRUPTING OCCUPIED OPERATIONS AND INCURRING SIGNIFICANT COST FOR CLOSE UP EXAMINATION AND NON-DESTRUCTIVE TESTING
DURING THE DESIGN STAGE.
1.02 WITH THE PASSAGE OF TIME SINCE THE CREATION OF AS-BUILT DRAWINGS AND/OR THE DESIGNERS SURVEY, BOTH CONCEALED AND VISIBLE CONDITIONS MAY HAVE CHANGED DUE TO ALTERATIONS, ADDITIONS, RENOVATIONS, AND DETERIORATION.
1.03 PRIOR TO THE COMMENCEMENT OF ANY WORK IN PREPARATION OF CONSTRUCTION RELATED ACTIVITIES ALL BURIED, EMBEDDED, CONCEALED ITEMS LIKELY TO BE ENCOUNTERED DURING CONSTRUCTION SHALL BE LOCATED AND MARKED ON THE SURFACE. THIS WORK SHALL BE ACCOMPLISHED BY DESTRUCTIVE
AND/OR NON-DESTRUCTIVE MEANS WITHOUT IMPAIRING THE STRUCTURAL INTEGRITY OF THE
ASSOCIATED MEMBERS. SHORING AS REQUIRED SHALL BE DESIGNED BY A PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE STATE OF THE PROJECT, AND FURNISHED AND INSTALLED AT NO ADDITIONAL
COST.
1.04 EXISTING CONDITIONS THAT INTERFERE OR OTHERWISE AFFECT THE DESIGN, CONSTRUCTION OR SERVICEABILITY OF THE WORK SHALL BE BROUGHT TO THE ATTENTION OF THE COR, INCLUDING PLAN AND SECTION SKETCHES, IMMEDIATELY FOR RESOLUTION. THE CONTRACTOR SHALL ALLOW TWO CALENDAR WEEKS IN THE SCHEDULE FOR DESIGN RESOLUTION OF THE INTERFERENCE AFTER ALL INFORMATION ABOUT THE INTERFERENCE, INCLUDING SIZE, LOCATION, AND FUNCTION OF THE EMBEDMENT, HAS BEEN
RECEIVED BY THE COR.
SPECIAL INSPECTIONS
1.01 SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER 17 OF THE BUILDING CODE
REFERENCED ABOVE AS DEFINED IN THE SPECIFICATION 0145 35.
GENERAL STRUCTURAL NOTES
1.01 ELEVATIONS AS SHOWN ON THE STRUCTURAL DRAWINGS ARE ELEVATIONS RELATIVE TO THE
FINISHED FIRST FLOOR.
1.02 WHERE A DETAIL, TYPICAL DETAIL, SECTION, TYPICAL SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL SIMILAR OR LIKE CONDITIONS UNLESS OTHERWISE NOTED.
1.03 THE STRUCTURAL DESIGN OF THE BUILDING IS BASED ON THE FULL INTERACTION OF ALL ITS
COMPONENT PARTS, WITH NO PROVISION MADE FOR CONDITIONS OCCURRING DURING
CONSTRUCTION. THEREFORE, CONTRACTOR SHALL PROVIDE ADEQUATE BRACING AND TEMPORARY
SHORING DURING CONSTRUCTION IN ACCORDANCE WITH APPLICABLE STANDARDS.
1.04 CONTRACTOR IS RESPONSIBLE FOR ALL JOB SITE SAFETY INCLUDING THE SAFE RIGGING, LIFTING, BRACING AND SETTING OF MATERIALS AND EQUIPMENT IN ACCORDANCE WITH APPLICABLE
STANDARDS.
1.05 FURNISH AND INSTALL ALL NECESSARY ATTACHMENTS, ANCHORAGES AND ACCESSORIES TO PROVIDE A COMPLETE STRUCTURALLY SOUND BUILDING, STRUCTURE WITH A CONTINUOUS LOAD PATH. BRING
ANY DISCONTINUITIES TO THE ATTENTION OF THE COR IMMEDIATELY.
1.06 FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF FABRICATION OR CONSTRUCTION.
BRING ANY DISCREPANCIES ALONG WITH DETAILED FIELD SKETCHES OF AS-BUILT CONDITIONS TO THE
ATTENTION OF THE COR IMMEDIATELY.
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
STRUCTURAL NOTES STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S001
590-20-104
06/04/2021
100% CONSTRUCTION
DOCUMENTS
DCASLW
STRUCTURAL STEEL NOTES
1.01 GENERAL
A. GENERAL REQUIREMENTS
1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN
ACCORDANCE WITH THE MANUAL OF STEEL CONSTRUCTION, BY THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION, INC..
B. DELIVERY, STORAGE AND HANDLING
1. PROTECT FROM CORROSION, DEFORMATION, AND OTHER TYPES OF DAMAGE. STORE
ITEMS IN AN ENCLOSED AREA FREE FROM CONTACT WITH SOIL AND WEATHER.
REMOVE AND REPLACE DAMAGED ITEMS WITH NEW ITEMS.
3.02 PRODUCTS
A. MATERIALS:
1. ALL OTHER SHAPES, PLATES AND BARS SHALL BE IN CONFORMANCE WITH ASTM A 36,
LATEST ADOPTED EDITION, UNO.
B. FINISH:
1. SURFACE PREPARATION:
a. UNLESS NOTED OTHERWISE, SHOP CLEAN THE SURFACE OF ALL STRUCTURAL
STEEL IN ACCORDANCE WITH THE REQUIREMENTS OF SSPC-SP2
2. PRIMER:
a. UNLESS NOTED OTHERWISE SHOP PAINT WITH A MINIMUM OF 1.0 MILS OF THE
FABRICATORS STANDARD RUST INHIBITIVE PRIMER.
3. FINISH COAT:
a. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
3.03 EXECUTION
A. EXAMINATION
1. PRIOR TO STRUCTURAL STEEL ERECTION, ERECTOR SHALL INSPECT EXISTING
CONSTRUCTION FOR CORRECT SIZE, LAYOUT AND ALIGNMENT. ANY INCONSISTENCIES
DEEMED DETRIMENTAL TO THE ERECTION OF STEEL SHALL BE REPORTED AND
REPAIRED PRIOR TO INSTALLATION.
B. FIELD QUALITY CONTROL
1. TOLERANCES
a. FABRICATION TOLERANCES SHALL BE IN CONFORMANCE WITH THE CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES BY THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION, MARCH 18, 2005.
2. WELDED CONNECTIONS:
a. ALL WELDS SHALL BE VISUALLY EXAMINED.
C. REPAIR
1. PROTECTIVE COATINGS DAMAGED DURING THE TRANSPORTATION, ERECTION AND FIELD
WELDING PROCESSES SHALL BE REPAIRED IN THE FIELD TO MATCH THE SHOP APPLIED
COATING.
POST-INSTALLED ANCHORS
1.01 POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE
COR PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED
CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS
TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED IN
ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. SUBSTITUTION
REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED
BY THE CONTRACTOR TO THE COR ALONG WITH CALCULATIONS THAT ARE PREPARED &
SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL
DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE
PERTINENT EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT
USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE
BUILDING CODE.
1.02 CONCRETE ANCHORS
A. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE
BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES
AC193. PRE-APPROVED MECHANICAL ANCHOR MANUFACTURERS:
1. SIMPSON STRONG-TIE ANCHORING SYSTEMS
2. HILTI
3. POWERS
B. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE
BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. PRE-
APPROVED ADHESIVE ANCHOR MANUFACTURERS
1. SIMPSON STRONG-TIE ANCHORING SYSTEMS
2. HILTI
3. POWERS
1.03 MASONRY ANCHORS
A. ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY
1. MECHANICAL AND CONCRETE SCREW ANCHORS FOR USE IN SOLID-GROUTED
CONCRETE MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ICC-ES AC01 OR AC106, RESPECTIVELY. PRE-APPROVED
MECHANICAL AND CONCRETE SCREW ANCHOR MANUFACTURERS:
a. SIMPSON STRONG-TIE SYSTEMS
b. HILTI
c. POWERS
2. ADHESIVE ANCHORS FOR USE IN SOLID-GROUTED CONCRETE MASONRY SHALL HAVE
BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58. PRE-
APPROVED ADHESIVE ANCHORS MANUFACTURERS:
a. SIMPSON STRONG-TIE SYSTEMS
b. HILTI
c. POWERS
B. ANCHORAGE TO HOLLOW CONCRETE MASONRY/UNREINFORCED CLAY BRICK MASONRY
SCREW ANCHORS FOR USE IN HOLLOW CONCRETE MASONRY SHALL HAVE BEEN TESTED
AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC106. PRE-APPROVED SCREW ANCHOR
MANUFACTURERS:
1. SIMPSON STRONG-TIE SYSTEMS
2. HILTI
3. POWERS
C. ADHESIVE ANCHORS WITH SCREEN TUBES SHALL BE TESTED AND QUALIFIED IN
ACCORDANCE WITH ICC-ES AC58 OR AC60, AS APPROPRIATE. THE APPROPRIATE SCREEN
TUBE SHALL BE USED AS RECOMMENDED BY THE ADHESIVE MANUFACTURER. PRE-
APPROVED ADHESIVE ANCHORS WITH SCREEN TUBE MANUFACTURERS:
1. SIMPSON STRONG-TIE SYSTEMS
2. HILTI
WOOD NOTES
1.01 GENERAL
A. CONTRACTOR SHALL PROVIDE ALL NECESSARY SHORING AND BRACING FOR ALL
STRUCTURAL ELEMENTS DURING CONSTRUCTION.
B. LUMBER IN CONTACT WITH CONCRETE AND OR MASONRY SHALL BE PRESSURE TREATED
IN ACCORDANCE WITH AWPB LP-2
1.02 TREATED WOOD PRODUCTS.
A. ALL TREATED LUMBER SHALL COMPLY WITH THE REQUIREMENTS OF "AWPA U1-05- USE
CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD" FOR WOOD
TREATMENTS DETERMINED BY USE CATEGORIES, EXPECTED SERVICE CONDITIONS, AND
SPECIFIC APPLICATIONS.
1. UCFA & UCFB CAN USE REGULAR GALVANIZED FASTENERS AND CONNECTORS.
B. TREATED MATERIAL SHALL BE DRIED AFTER TREATMENT TO A MOISTURE CONTENT OF NOT
MORE THAN 19% FOR LUMBER AND 15% FOR PLYWOOD.
C. APPLY WOOD TREATMENT COMPATIBLE WITH FACTORY APPLIED TREATMENT AT SITE-SAWN
CUTS, COMPLYING WITH MANUFACTURERS INSTRUCTIONS. ALLOW TREATMENTS TO DRY PRIOR
TO ERECTING MEMBERS.
1.03 SAWN LUMBER SHALL BE PROVIDED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION
FOR WOOD CONSTRUCTION, BY THE AMERICAN FOREST & PAPER ASSOCIATION.
A. LUMBER GRADE AND SPECIES SHALL CONFORM TO THE LUMBER GRADE & SPECIES SCHEDULE.
ALL LUMBER SHALL BE IDENTIFIED BY AN AFFIXED GRADE MARK OF A LUMBER GRADING OR
INSPECTING AGENCY. LUMBER AND WOOD PANELS SHALL NOT CONTAIN MORE THAN 19%
MOISTURE AT THE TIME OF INSTALLATION.
B. PROVIDE DOUBLE TOP PLATE LAPPED AT CORNERS AND AT SPLICES (4' SPLICE).
C. PROVIDE FULL HEIGHT TRIPLE STUDS AT CORNERS. PROVIDE FULL HEIGHT DOUBLE STUDS AT
EACH SIDE OF OPENINGS LESS THAN 6' WIDE PLUS ONE TRIMMER STUD.
D. HOLES IN JOISTS, RAFTERS, STUDS AND PLATES NOT EXCEEDING 1/5 THE DEPTH/WIDTH OF THE
MEMBER AND NOT CLOSER THAN 3 TIMES THE DEPTH/WIDTH OF THE MEMBER FROM THE END
ARE PERMITTED AT THE MID-DEPTH/WIDTH OF THE MEMBER.
E. BRIDGING, FULL DEPTH SOLID BLOCKING, OR CROSS BRACING SHALL BE INSTALLED AT
INTERVALS NOT EXCEEDING 8 FT O.C. WHEN THE DEPTH TO BREADTH RATIO OF SAWN JOISTS
AND RAFTERS EXCEEDS 6 TO 1.
1.04 PLYWOOD SHALL BE PROVIDED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE AMERICAN PLYWOOD ASSOCIATION (APA). THE MINIMUM THICKNESS' WHICH FOLLOW SHALL BE INCREASED AS
REQUIRED TO SATISFY ARCHITECTURAL REQUIREMENTS.
A. WALL SHEATHING SHALL BE 15/32" APA RATED SHEATHING, 32/16, EXPOSURE I, 48" X 96" WITH
CONTINUOUSLY 2X MINIMUM SUPPORTED EDGES UNO. AN 1/8" GAP SHALL BE LEFT BETWEEN
ADJACENT PANELS.
1. FASTEN SHEATHING WITH 8D NAILS @ 6" O/C (6" MAXIMUM) AT 2X MINIMUM PANEL EDGES AND
@ 12" O/C AT INTERMEDIATE SUPPORTS UNO. (V = 260LBS./FT @ 6" O/C, V = 380LBS./FT @ 4" O/C, V = 490LBS./FT @ 3" O/C) FASTEN SHEATHING WITH #8 X 1" BUGLE HEAD SCREWS @ 6" O/C AT PANEL EDGES AND @ 12" O/C AT INTERMEDIATE 2X MINIMUM SUPPORTS. (V=200 PLF @ 6"
O/C, V=300 PLF @ 4" O/C, V=390 PLF @ 3" O/C)
1.05 TIMBER DECKING
A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) BEVELED V-JOINT WITH TONGUE AND
GROOVE IN ACCORDANCE WITH AITC 112 SELECT QUALITY.
B. SPECIES SHALL BE NO. 2 GRADE OR BETTER, SOUTHERN PINE, SOUTHERN PINE INSPECTION
BUREAU (SPIB) KILN DRIED TO 15% AT DELIVERY.
C. PATTERN SHALL BE EDGE VEE ONE SIDE (EV1S).
D. LENGTHS SHALL BE CONTROLLED RANDOM LAYUP: END MATCHED DECKING.
E. INSTALLATION
1. INSTALL IN ACCORDANCE WITH AITC 112 UNO.
2. TONGUE-AND-GROOVE WOOD DECKING IS TO BE INSTALLED WITH TONGUES UP ON SLOPED
OR PTCHED ROOFS, AND OUTWARD IN DIRECTION OF LAYING FOR FLAT OR SPAN IN
DIRECTION OF OR PARREL TO THE SLOPE.
3. FASTENING
a. (1) 16d COMMON TOE NAIL THROUGH TONGUE, (1) 16d COMMON FACE NAILS AT EACH
SUPPORT FOR EACH BOARD. GLUE JOINT.
b. (1) 16d COMMON TOE NAIL THROUGH TONGUE, (2) 16d COMMON FACE NAILS AT EACH
SUPPORT FOR EACH BOARD.
1.06 ENGINEERED LUMBER SHALL BE FURNISHED IN THE SIZES SPECIFIED ON THE DRAWINGS AND
PRODUCED BY THE FOLLOWING MANUFACTURERS:
A. LAMINATED VENEER LUMBER (LVL): 2.0E MICROLLAM LVL BY WEYERHAEUSER OR EQUAL.
1. Fb = 2,600 PSI
2. Ft = 1,895 PSI
3. Fc-perp = 750 PSI (PERPENDICULAR TO GRAIN)
4. Fc-parallel = 2,510 PSI (PARALLEL TO GRAIN)
5. Fv = 285 PSI
6. SG = 0.50
B. PARALLEL STRAND LUMBER (PSL) BEAM: PARALLAM PSL BY WEYERHAEUSER OR EQUAL.
1. Fb = 2,900 PSI
2. Ft = 2,300 PSI
3. Fc-perp = 625 PSI (PERPENDICULAR TO GRAIN)
4. Fc-parallel = 2,900 PSI (PARALLEL TO GRAIN)
5. Fv = 290 PSI
6. SG = 0.50
USE
CATEGORY
SERVICE
CONDITIONS
EXAMPLES
CONNECTOR
FINISH
FASTENER
FINISH
UNTREATED INTERIOR
CONSTRUCTION
ABOVE DRY
GROUND
ROOF
TRUSSES
ASTM A653
G185
ASTM A153
UC2 INTERIOR
CONSTRUCTION
ABOVE DAMP
GROUND
INTERIOR
CONSTRUCTION
EXPOSED TO
OCCASIONAL
SOURCES OF
MOISTURE AND
SILL PLATES
ASTM A653
G185
ASTM A153
UCFA ROOF
SHEATHING,
ROOF
TRUSSES,
STUDS, JOISTS
AND PANELING
ASTM A653 G185 ASTM A153FIRE
PROTECTION
AS REQUIRED
BY CODES
ABOVE
GROUND
INTERIOR
CONSTRUCTION
WOOD NOTES (CTD.)
1.07 FASTENING SCHEDULE SHALL BE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE TABLE
2304.9.1 UNLESS OTHERWISE SPECIFIED OR MODIFIED ON THE FASTENING SCHEDULE.
1.08 SILL ANCHOR
A. HEADED ANCHOR BOLTS SHALL CONFORM TO ASTM F 1554 GRADE 36 OR A36 UNLESS NOTED
OTHERWISE.
B. ALL SILL ANCHORS SHALL BE HOT DIPPED GALVANIZED.
C. BOLT HEADS AND NUTS SHALL BE HEAVY HEX. ANCHOR BOLTS SHALL BE A MINIMUM OF 5/8 IN.
DIA. EQUAL SIZE AND STRENGTH THREADED RODS WITH TACK WELDED NUTS MAY BE USED IN
LIEU OF BOLTS.
D. ANCHOR BOLTS SHALL BE PROVIDED WITH A HARDENED STEEL WASHER IN ACCORDANCE WITH
ASTM F 436 - 93 UNO.
E. ANCHOR BOLTS SECURING WOOD PLATES SHALL BE PROVIDED WITH 1/4 IN. X 2-1/2 IN. X 2-1/2 IN.
BEARING PLATE BP 5/8 IN. BY SIMPSON STRONG-TIE COMPANY INC.
F. UNO SILL PLATE ANCHORS SHALL BE SPACED AT A MAXIMUM SPACING OF 32"o/c AND NOT LESS THAN 4" NOR MORE THAN 12" FROM THE END OF EACH PLATE SECTION OR CORNER. EACH SILL
PLATE SEGMENT SHALL HAVE AT LEAST TWO (2) BOLTS.
G. ANCHOR BOLTS SECURING WOOD PLATES AT STRUCTURAL AND FIRE RATED WALLS SHALL BE
EMBEDDED A MINIMUM OF 7 IN. INTO CONCRETE OR MASONRY.
H. POWDER ACTUATED FASTENERS MAY BE USED TO ANCHOR NON-LOAD BEARING AND NON-
SHEARWALL SILLS TO CONCRETE WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH f'c = 2,000
PSI. FASTENERS SHALL BE SPACED AT STUD SPACING NOT TO EXCEED 18 IN. O/C WITH ONE
FASTENER AT 6 IN. AND AT 10 IN. FROM THE END OF THE PLATE. MINIMUM FASTENER DIAMETER
IS 0.145 IN. DIA. MINIMUM EMBEDMENT IS 1 IN.. MINIMUM CONCRETE EDGE DISTANCE AT
EXTERIOR WALLS IS 1-3/4 IN. AND 2-3/4 IN. AT INTERIOR WALLS. THE FOLLOWING PRODUCTS ARE
ACCEPTABLE FOR PRESSURE TREATED SILLS IN DRY AREAS:
1. HILTI: X-CP 72 P8 S23.
2. SIMPSON: PDPWL-300MG. 1" MIN PEN
3. POWERS: 50115MG
I. POWDER ACTUATED FASTENERS SHALL NOT BE USED ALONG SHEARWALLS DESIGNED TO
RESIST MORE THAN 100 PLF.
STRUCTURAL DRAWING ABBREVIATIONS:
BOT BOTTOM
B/STL BOTTOM OF STEEL
C.J. CONSTRUCTION OR CONTROL JOINT
CJT CORNER JACK TRUSS
CMU CONCRETE MASONRY UNIT
CONN CONNECTION
DBA DEFORMED BAR ANCHOR
DIAG DIAGONAL
EA EACH
EF EACH FACE
EL ELEVATION
EMBED EMBEDMENT
EOD EDGE OF DECK
EOS EDGE OF SLAB
EW EACH WAY
EXF EXISTING FOOTING
FOB FACE OF BRICK
FF FAR FACE
FP FACE OF PANEL
FX FOOTING MARK NUMBER (SEE SCHEDULE)
GT GIRDER TRUSS
HORIZ HORIZONTAL
IFW INSIDE FACE OF WALL
JB JOIST BEARING
JT JACK TRUSS
LBW LOAD BEARING WALL
LLH LONG LEG HORIZONTAL
LLO LONG LEG OUT
LLV LONG LEG VERTICAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
MAX. MAXIMUM
MIN. MINIMUM
NDS NATIONAL DESIGN STANDARD
FWC FOR WOOD CONSTRUCTION
NF NEAR FACE
OC ON CENTER
OFW OUTSIDE FACE OF WALL
PAF POWDER ACTUATED FASTENER
PC PRECAST
PDF POWDER DRIVEN FASTENER
PJF PREMOLDED JOINT FILLER
PLF POUNDS PER LINEAR FOOT
P.T. PRESSURE TREATED
PXXX PIER MARK NUMBER (SEE SCHEDULE)
RRS REBAR REINFORCING STEEL
SOG SLAB-ON-GROUND
STD STANDARD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE DECKING
T/FTG TOP OF FOOTING
T/STL TOP OF STEEL
T/U TILT-UP
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT VERTICAL
WWR WELDED WIRE REINFORCEMENT
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
STRUCTURAL NOTES STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S002
590-20-104
06/04/2021
100% CONSTRUCTION
DCASLW
IBC 2018 TABLE 2304.10.1 - FASTENING SCHEDULE
BLOCKING BETWEEN CEILING JOISTS,
RAFTERS, OR TRUSSES TO TOP PLATE OR
OTHER FRAMING BELOW
3-8D COMMON (2 1/2" x 0.131")
EACH END, TOENAIL
CONNECTION FASTENING, NUMBER, AND TYPE SPACING AND LOCATION
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
2-8D COMMON (2 1/2" X 0.131")
2-3" x 0.131" NAIL
2-3" x 14 GAGE STAPLE
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE
2-16D COMMON (3 1/2" X 0.162")
EACH END, TOENAIL
END NAIL
BLOCKING BETWEEN RAFTERS OR TRUSS
NOT AT THE WALL TOP PLATE, TO RAFTER
OR TRUSS
FLAT BLOCKING TO TRUSS AND WEB FILLER
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE
16D COMMON (3 1/2" X 0.162")
FACE NAIL @ 6" O.C.
3-8D COMMON (2 1/2" x 0.131")
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
EACH JOIST, TOENAIL2 CEILING JOISTS TO TOP PLATE
3-16D COMMON (3 1/2" x 0.162")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
4-10D BOX (3" x 0.128")
CEILING JOIST NOT ATTACHED TO
PARALLEL RAFTER, LAPS OVER PARTITIONS
(NO THRUST) (SEE IBC 2018 SECTION
2308.7.3.1, TABLE 2308.7.3.1)
3 FACE NAIL
CEILING JOIST ATTACHED TO PARALLEL
RAFTER (HEEL JOINT) (SEE IBC 2018 SECTION
2308.7.3.1, TABLE 2308.7.3.1)
PER IBC 2018 TABLE 2308.7.3.1 FACE NAIL
3-10D COMMON (3" x 0.148")
4-10D BOX (3" x 0.128")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
FACE NAILCOLLAR TIE TO RAFTER5
ROOF
6 RAFTER OR ROOF TRUSS TO TOP PLATE (SEE
SECTION 2308.7.5, TABLE 2308.7.5
3-10D COMMON (3" x 0.148")
4-10D BOX (3" x 0.128")
3-16D BOX (3 1/2" x 0.135")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
7 ROOF RAFTERS TO RIDGE VALLEY OR HIP
RAFTERS; OR ROOF RAFTERS TO 2-INCH
RIDGE BEAM
2-16D COMMON (3 1/2" x 0.162")
3-10D BOX (3" x 0.128")
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D COMMON (3" x 0.148")
4-10D BOX (3" x 0.128")
4-16D BOX (3 1/2" x 0.135")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
WALL
STUD TO STUD (NOT AT BRACED WALL
PANELS)
16D COMMON (3 1/2" x 0.162")
3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
10D BOX (3" x 0.128")
16D COMMON (3 1/2" x 0.162")
16D BOX (3 1/2" x 0.135")
3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
STUD TO STUD AND ABUTTING STUDS AT
INTERSECTING WALL CORNERS (AT BRACED
WALL PANELS)
16D COMMON (3 1/2" x 0.162")
16D BOX (3 1/2" x 0.135")
TOENAIL
c
END NAIL
TOENAIL
FACE NAIL @ 24" O.C.
FACE NAIL @ 16" O.C.
FACE NAIL @ 16" O.C.
FACE NAIL @ 12" O.C.
10 BUILT-UP HEADER (2" TO 2" HEADER)
16" O.C. FACE EA. EDGE
12" O.C. FACE EA. EDGE
4-8D COMMON (2 1/2" x 0.131")
CONNECTION FASTENING, NUMBER, AND TYPE SPACING AND LOCATION
4-10D BOX (3" x 0.128")
11 CONTINUOUS HEADER TO STUD
12 TOP PLATE TO TOP PLATE
16D COMMON (3 1/2" x 0.162")
3" x 0.131" NAIL
3" 14 GAGE STAPLE, 7/16" CROWN
10D BOX (3" x 0.128")
8-16D COMMON (3 1/2" x 0.162")
12-3" x 0.131" NAIL
12-3" 14 GAGE STAPLE, 7/16" CROWN
12-10D BOX (3" x 0.128")
13 TOP PLATE TO TOP PLATE, @ END JOINTS
BOTTOM PLATE TO JOIST, RIM JOIST,
BAND JOIST, OR BLOCKING (NOT AT
BRACED WALL PANELS)
16D COMMON (3 1/2" x 0.162")
3" x 0.131" NAIL
3" 14 GAGE STAPLE, 7/16" CROWN
16D BOX (3 1/2" x 0.135")
TOENAIL
FACE NAIL @ 12" O.C.
EACH SIDE OF END JOINT,
FACE NAIL (MIN. 24" LAP
SPLICE LENGTH EACH
SIDE OF END JOINT)
BOTTOM PLATE TO JOIST, RIM JOIST, BAND
JOIST, OR BLOCKING AT BRACED WALL
PANELS
2-16D COMMON (3 1/2" x 0.162")
3-16D BOX (3 1/2" x 0.135")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
16 STUD TO TOP OR BOTTOM PLATE
2-16D COMMON (3 1/2" x 0.162")
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
4-8D COMMON (2 1/2" x 0.131")
4-3" x 0.131" NAIL
4-10D BOX (3" x 0.128")
4-3" 14 GAGE STAPLE, 7/16" CROWN
TOP PLATES, LAPS AT CORNERS AND
INTERSECTIONS
2-16D COMMON (3 1/2" x 0.162")
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
1" BRACE TO EACH STUD END PLATE
1"x6" SHEATHING TO EACH BEARING
1" x 8" AND WIDER SHEATHING TO EACH
BEARING
JOIST TO SILL, TOP PLATE, OR GIRDER
RIM JOIST, BAND JOIST, OR BLOCKING TO
TOP PLATE, SILL, OR OTHER FRAMING
BELOW
1" x 6" SUBFLOOR OR LESS TO EACH JOIST
2" SUBFLOOR TO JOIST OR GIRDER
2" PLANKS (PLANK AND BEAM)
2" PLANKS (FLOOR AND ROOF)
2-8D COMMON (2 1/2" x 0.131")
2-10D BOX (3" x 0.128")
2-3" x 0.131" NAIL
2-3" 14 GAGE STAPLE, 7/16" CROWN
2-8D COMMON (2 1/2" x 0.131")
2-10D BOX (3" x 0.128")
3-8D COMMON (2 1/2" x 0.131")
2-10D BOX (3" x 0.128")
3-8D COMMON (2 1/2"x 0.131") OR FLOOR
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
8D COMMON (2 1/2" x 0.131")
3" x 0.131" NAIL
3" 14 GAGE STAPLE, 7/16" CROWN
10D BOX (3" x 0.128")
2-8D COMMON (2 1/2" x 0.131")
2-10D BOX (3" x 0.128")
2-16D COMMON (3 1/2" x 0.162")
2-16D COMMON (3 1/2" x 0.162")
2-16D COMMON (3 1/2" x 0.162")
FACE NAIL @ 16" O.C.
END NAIL
TOENAIL
FACE NAIL
FACE NAIL
FACE NAIL
FACE NAIL
TOENAIL
TOENAIL @ 6" O.C.
FACE NAIL
FACE NAIL
EACH BEARING,FACE NAIL
EACH BEARING,FACE NAIL
20D COMMON (4" x 0.192")
CONNECTION FASTENING, NUMBER, AND TYPE SPACING AND LOCATION
BUILT-UP GIRDERS AND BEAMS, 2"
LUMBER LAYERS
3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
10D BOX (3" x 0.128")
AND:
2-20D COMMON (4" x 0.192")
3-3" x 0.131" NAIL
3-3" 14 GAGE STAPLE, 7/16" CROWN
3-10D BOX (3" x 0.128")
LEDGER STRIP SUPPORTING JOISTS OR
RAFTERS
3-16D COMMON (3 1/2" x 0.162")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
4-10D BOX (3" x 0.128")
28 JOIST TO BAND JOIST OR RIM JOIST
3-16D COMMON (3 1/2" x 0.162")
4-3" x 0.131" NAIL
4-3" 14 GAGE STAPLE, 7/16" CROWN
4-10D BOX (3" x 0.128")
2-8D COMMON (2 1/2" x 0.131")
2-3" x 0.131" NAIL
2-3" 14 GAGE STAPLE, 7/16" CROWN
2-10D BOX (3" x 0.128")
29 BRIDGING OR BLOCKING TO JOIST,
RAFTER, OR TRUSS
FACE NAIL 32" O.C. T&B,
STAGGERED OPP SIDES
FACE NAIL 24" O.C. T&B,
STAGGERED OPP SIDES
CONNECTION FASTENING, NUMBER, AND TYPE
6D COMMON OR DEFORMED (2" x 0.113") (SUBFLOOR
& WALL)
WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF, AND INTERIOR WALL SHEATHING TO FRAMING
AND PARTICLE BOARD WALL SHEATHING TO FRAMING
8D COMMON OR DEFORMED (2 1/2" x 0.131") (ROOF) OR RSRS-01 (2 3/8" x 0.113") NAIL (ROOF)
2 3/8" x 0.113" NAIL (SUBFLOOR AND WALL)
1 3/4" 16 GAGE STAPLE, 7/16" CROWN (SUBFLOOR & WALL)
2 3/8" x 0.113" NAIL (ROOF)
1 3/4" 16 GAGE STAPLE, 7/16" CROWN (ROOF)
8D COMMON (2 1/2" x 0.131") (SUBFLOOR AND WALL)
6D DEFORMED (2 1/2" x 0.113") (SUBFLOOR AND WALL)
8D COMMON OR DEFORMED (2 1/2" x 0.131") OR RSRS-01 (2 3/8" x 0.113") NAIL (ROOF) d d
OTHER EXTERIOR WALL SHEATHING
WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING
PANEL SIDING TO FRAMING
WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF, AND INTERIOR WALL SHEATHING TO FRAMING AND
PARTICLEBOARD WALL SHEATHING TO FRAMING , INTERIOR PANELING
a
2 3/8" x 0.113" NAIL
2" 16 GAGE STAPLE, 7/16" CROWN
10D COMMON (3" x 0.148")
8D DEFORMED (2 1/2" x 0.131")
1 1/2" GALVANIZED ROOFING NAIL (7/16" HEAD DIAMETER)
1 1/4" 16 GAGE STAPLE, 7/16" OR 1" CROWN
1 3/4" GALVANIZED ROOFING NAIL (7/16" HEAD DIAMETER)
1 1/4" 16 GAGE STAPLE, 7/16" OR 1" CROWN
8D COMMON (2 1/2" x 0.131")
6D DEFORMED (2" x 0.113")
8D COMMON (2 1/2" x 0.131")
8D DEFORMED (2 1/2" x 0.131")
10D COMMON (3" x 0.148")
8D DEFORMED (2 1/2" x 0.131")
6D CORROSION-RESISTANT SIDING (1 7/8" x 0.106")
6D CORROSION-RESISTANT CASING (2" x 0.099")
8D CORROSION-RESISTANT SIDING (2 3/8" x 0.128")
8D CORROSION-RESISTANT CASING (2 1/2" x 0.113")
4D CASING (1 1/2" x 0.080")
4D FINISH (1 1/2" x 0.072")
6D CASING (2" x 0.099")
6D FINISH (PANEL SUPPORTS AT 24 INCHES)
3/8" - 1/2"
19/32" - 3/4"
7/8" - 1 1/4"
1/2" FIBERBOARD SHEATHING
25/32" FIBERBOARD SHEATHING
3/4" AND LESS
7/8" - 1"
1 1/8" - 1 1/4"
1/2" OR LESS
5/8"
1/4"
3/8" b
SPACING AND LOCATION
EDGES (IN.) INTERMEDIATE
SUPPORTS (IN.)
6 12
6 12
6 12
4 8
4 8
3 6
6 12
4 8
6 12
6 12
3 6
3 6
6 12
6 12
6 12
6 12
6 12
6 12
6 12
NOTES TO TABLE 2304.10.1
FOR SI: 1 INCH = 25.4 MM
A. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO IBC 2018 SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX, OR CASING B. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED) C. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ONE NAIL D. RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667.
FACE NAIL, ENDS AND
AT EACH SPLICE
FACE NAIL, EACH
JOIST OR RAFTER
END NAIL
EACH END, TOENAIL
FACE NAIL @ 16" O.C.
FACE NAIL @ 16" O.C.
FACE NAIL @ 12" O.C.
FLOOR
a b
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
FASTENING SCHEDULE STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S003
590-20-104
06/04/2021
100% CONSTRUCTION
AuthorChecker
R E
F
/4
REF
28' - 9"
R E
F
1/ 2"
1x4 AND 1x6 T&G DECKING WITH
(ASSUMED) CORK INSULATION
& CONCRETE TOPPING
EXISTING 2x12 @ 16" O.C.
LOAD BEARING
MASONRY WALLS
LOAD BEARING
MASONRY WALLS
7" A
B
3'
6"
9' - 1"
F
B
10' - 9"
A
3'
0"
4'
0"
4' - 0"
4'
0"
3'
0"
B
6'
0"
4'
0"
F
A
S601S101
4'
5'
5'
S601S101
PLAN
NORTH
TRUE
NORTH
E X
IS
T
. 4 x8
O
.C
EXIST. 2x8 @ 16" O.C.
LOAD BEARING
MASONRY WALL
1x4 AND 1x6 T&G
DECKING WITH (2)
LAYERS OF CORK
INSULATION
8x S
T E
E L
B E
A M
8x S
T E
E L
B E
A M
8x S
T E
E L
B E
A M
LOAD BEARING
MASONRY WALL
8x S
T E
E L
B E
A M
8x S
T E
E L
B E
A M
8x S
T E
E L
B E
A M
B11' - 3"
3'
0"
7' - 0"
13' - 6"
2'
0"
B A
7' - 0"
5' - 0"
0"
4'
0"
S601S101
S601S101
14' - 0 1/2"
T&G
A
B
C
D
E
F DETERIORATED JOIST. REPLACE FULL LENGTH
DETERIORATION
X
"#" DENOTES L.F. OF DAMAGE EA.
DETERIORATED CORNER JACK
CORRODED STEEL - REPAINT
DETERIORATED RAFTER TAIL
DETERIORATED TONGUE AND GROOVE PLANKING.
REPLACE IN KIND.
DETERIORATED JOIST OR RAFTER
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
FRAMING PLANS STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S101
590-20-104
06/04/2021
100% CONSTRUCTION
DOCUMENTS
DCASLW
1/4" = 1'-0"S101
1 LOWER ICE ROOM CEILING FRAMING PLAN
Scale: 1/4"=1'-0"
1' 4' 8' 12
1/4" = 1'-0"S101
2 UPPER ICE ROOM CEILING FRAMING PLAN
KEY PLAN
KEY NOTESNOTE: ALL DAMAGE DIMENSIONS ARE FOR REFERENCE ONLY. VERIFY IN FIELD.
NOTE: ALL DAMAGE DIMENSIONS ARE FOR REFERENCE ONLY. VERIFY IN FIELD.
FINISH FLOOR EL. = 9' - 5 1/2"
T/STEEL EL. = 18' - 0 1/2"
T/SLAB BASEMENT EL. = FINISH FLOOR EL. = 0' - 0"
B
B
B
B
B
B
B
2x @ 24" O.C.
T&G DECKING
T&G DECKING
2x4 KNEE WALL
2x4 KNEE WALL
C
E
REPOINT 400' @ WALL.
REPLACE 4 BRICK. PERFORM
MORTAR ANALYSIS.
E
B
B
E
A
B
A
A
A
E 3x10 SILL REPLACE FULL LENGTH
A
A
A
B
B
NOTE: ALL DAMAGE DIMENSIONS ARE FOR REFERENCE ONLY. VERIFY IN FIELD.
S601S102
S601S101
T/SLAB WAREHOUSE = 5' - 2 1/2"
T/STEEL EL. = 21' - 6 1/2"
BEARING EL. = T/SILL EL. = 21' - 9 1/2"
S601S102
S102 S102
7'
4' E
4'
4'
9'
9'
D 20'
16'
11' A
9'6'
7'
9'
7'
4'
T&G
T&G
T&G
S102 S601
S601S102
S601S102
S601S102
S601S102
S601S102
REPLACE DAMAGED CORNER
JACK IN KIND. SHORE AS
REQUIRED.
BE
LO
W
PLAN
NORTH
TRUE
NORTH
EXIST. BEAM / JOIST
DENOTES DECK SPAN DIRECTION & DECK DESCRIPTION
A
B
C
D
E
F DETERIORATED JOIST. REPLACE FULL LENGTH
DETERIORATION
X
"#" DENOTES L.F. OF DAMAGE EA.
DETERIORATED CORNER JACK
CORRODED STEEL - REPAINT
DETERIORATED RAFTER TAIL
DETERIORATED TONGUE AND GROOVE PLANKING.
REPLACE IN KIND.
DETERIORATED JOIST OR RAFTER
REPLACE PLYWOOD
OVER OFFICE
12' - 6"
2x8 @ 16" O.C. TYP.
2x8
5'
4"
EXIST. BRICK MASONRY WALL
EXIST. EXTERIOR BRICK
MASONRY WALL
EXIST. DOUBLE DOORWAY
EXIST. DOORWAY BELOW
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
FRAMING PLANS STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S102
590-20-104
06/04/2021
100% CONSTRUCTION
DOCUMENTS
DCASLW
1/4" = 1'-0"S102
1 ROOF FRAMING PLAN
ROOF FRAMING LEGEND
KEY NOTES
Scale: 1/4"=1'-0"
1' 4' 8' 12
' KEY PLAN
3/4" = 1'-0"S102
2 WAREHOUSE OFFICE CEILING FRAMING PLAN
EXIST WAREHOUSE
EXIST LOWER ICE ROOM
EXIST ELEVATED CONCRETE SLAB AND STAIR @ EXTERIOR
EXIST CONCRETE
BEAM AND COLUMN
SPALLS
S103S103
S103S103
S103S103
S103 S103
NEW CONCRETE STAIR AT EXTERIOR DOOR
5'
0"
5' - 0"
5'
0"
PLAN
NORTH
TRUE
NORTH
EXIST EXTERIOR
HANDRAIL
EXIST REMOVEABLE TOEBOARD
EXIST ELEVATED
SLAB
NEW 4" x 1" x 5/16" PLATE
WELDED TO EXIST. HANDRAIL
1/4
S103S103
AFFECTED LENGTH
CROSS SECTION
LOSS OF 10% OR MORE
REQUIRED LAP REQUIRED LAP
AFFECTED LENGTH
SUPPLEMENTAL BAR
REMOVE UNSOUND CONCRETE FROM
REPAIR AREA. CAST TO RESTORE ORIGINAL
CROSS SECTION.
APPLY EPOXY
BONDING AGENT. SEE
SPECIFICATIONS.
EXISTING
CONCRETE
SAW CUT AROUND
PERIMETER OF SPALL
TO THE MINIMUM DEPTH
REQUIRED BY THE
REPAIR MORTAR USED.
EXISTING REINFORCING BARS, BLAST, CLEAN, AND COAT WITH
CORROSION INHIBITOR WHERE BARS ARE EXPOSED. SEE
SPECIFICATIONS. WHERE REINFORCEMENT IS FOUND TO BE SEVERELY
CORRODED OR HAS LOST 10% OR MORE OF ITS CROSS SECTIONAL
AREA, SUPPLEMENTARY REINFORCEMENT WILL BE REQUIRED. SEE
3/S103. IF CORROSION IS PRESENT ON EMBEDDED REINFORCEMENT
WHERE IT CONTACTS SOUND CONCRETE, ADDITIONAL CONCRETE
REMOVAL IS REQUIRED UNTIL SOUND REINFORCING IS ENCOUNTERED.
CHIP CONCRETE TO
EXPOSE A MIN 3/4"
ANNULAR SPACE
AROUND REINFORCING
STEEL.
3/4" MIN. CLEARANCE BEYOND REINFORCING
REFER TO DETAIL 4/S103
FOR CONCRETE REPAIR
EXISTING COLUMN
TIES & REINFORCING
NEW MATERIAL TO MATCH
ORIGINAL SURFACE,
SEE SPECIFICATIONS
EXIST. CONCRETE
COLUMN
REMOVE BEYOND DELAM.
TO SOUND CONCRETE
NOTES:
1. PROTECT EXISTING REINFORCEMENT FROM DAMAGE DURING
CHIPPING, GRINDING, OR SAW CUTTING.
2. IF REINFORCEMENT IS EXPOSED DURING SURFACE PREPARATION
THAT IS FOUND TO BE SEVERELY CORRODED OR HAS LOST 10% OR
MORE OF ITS CROSS SECTIONAL AREA, SUPPLEMENTARY
REINFORCEMENT WILL BE REQUIRED. REPORT TO COR TO REVIEW
AMOUNT OF SUPPLEMENTARY REINFORCEMENT REQUIRED. IF
CORROSION IS PRESENT ON EMBEDDED REINFORCEMENT WHERE IT
CONTACTS SOUND CONCRETE, ADDITIONAL CONCRETE REMOVAL IS
REQUIRED UNTIL SOUND REINFORCING IS ENCOUNTERED.
3. COLUMN DIMENSIONS MAY BE INCREASED BY UP TO 1" ON EACH SIDE
TO ALLOW FOR ADEQUATE CONCRETE COVER.
5"
0' - 4" SLAB WITH 6x6 - W7.5xW7.5
WWM @ MID DEPTH
#4 @ 48" O.C.
#5 @ 1' - 0" O.C.
#4 @ 12" O.C.
#4 @ 12" O.C.
(2) #4 CONT.
#3 NOSING TYP.
#4 @ 12" 0.C. E.W. E.F.
LEDGE
1'
0"
2' - 0"
T Y
P
1'
4"
7" RISE x 13" RUN TYP EA. RISER
0' - 4" SLAB WITH 6x6 - W7.5xW7.5
WWM @ MID DEPTH
EXIST BLDG 27
1' - 0"
3"
(2) #4 CONTINUOUS
(2) #5 CONTINUOUS
GRADE EL.
T/SLAB
B/DOOR EL.
COMPACTED FILL
#4 @ 12" O.C. E.W. CENTER
OF WALLS TYP (3) SIDES
NOSING. SEE ARCH.
EXIST.
REMOVEABLE
TOEBOARD
NEW 4" x 1" x 5/16"
PLATE WELDED
TO EXIST.
HANDRAIL
1/4
INSTALL EXIST.
TOEBOARD TO
SUPPORT
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
CONCRETE & STEEL
PLANS & DETAILS
STRUCTURAL REPAIR UPGRADE
BUILDING 27
HAMPTON, VA
S103
590-20-104
06/04/2021
100% CONSTRUCTION
DOCUMENTS
DCASLW
3/16" = 1'-0"S103
1 CONCRETE AND STEEL PLAN
KEY PLAN
3/4" = 1'-0"S103
2 NEW TOEBOARD @ EXT
3"…