This document outlines requirements for a community-based outpatient clinic in Harrison, Arkansas to be provided under a federal contract with the Department of Veterans Affairs. The contractor will be required to provide primary care and mental health support services at the clinic, located within the city limits of Harrison, to serve local veterans. Primary care services will include both medical and mental health support delivered both physically on site and via telehealth, as well as potential support services such as pharmacy, laboratory, and x-ray. Mental health services will be directly provided by the Veterans Health Care System of the Ozarks, while the contractor must supply mental health registered nurse support staff and dedicated space for VA mental health providers. The performance period and any further details regarding the response deadline or anticipated award date are not specified.
View the file
Other files for this federal contract opportunity
Show all 50
Q201--Harrison, AR Community Based Outpatient Center (CBOC) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VistA Imaging Approved PACS HL7 Interfaces 20 December 2017
VistA Imaging has tested HL7 interfaces between VistA and several commercial PACS (Picture Archiving and Communication Systems). The following list of commercial PACS was generated based on the most current information and will change as more information becomes available.
A PACS is considered to be Supported for HL7 communication if it passes the VA’s internet validation test suite that is based on the Profiles for HL7 Messaging between VistA and Commercial PACS .
If the software used in any part of the PACS HL7 interface is revised by the manufacturer, the PACS interface will need to be re-validated.
The VA retains the right to change PACS HL7 interface testing requirements at any time as needed for VA medical care. These changes could require re-testing of the PACS interfaces.
This list of approved PACS HL7 interfaces does not in any way constitute a product endorsement by the VA. It only states whether or not the listed product has passed the VA’s internet-based validation testing.
Upgrades to the vendor equipment can affect interoperability and may require re-validation. The validation process does not indicate how well the actual product will work operationally, either within the VA or elsewhere.
When a product does not at present assert support for a particular functionality (e.g., patient movement updates, report message storage) it will need to be validated for such functionality should the product later wish to assert support for it.
When two or more products are shown under Model and Version, all products and versions listed have been validated in tandem and are only supported when installed and run in tandem.
Manufacturer Model Version Date approved Notes* Agfa Impax 6.3.1 26 November 2008 1 Agfa Enterprise (Radiology/Cardiology) 8.x 1 January 2017 BRIT HL7Messenger 1.7.3 2 February 2011 1 Carl Zeiss FORUM 2 May 2014 6 Carestream Carestream PACS 11.0 25 November 2009 1 Carestream VuePACS 12.x 21 July 2017 Digisonics HL7 Manager 1.1.0 with DigiHL7 1.0.0 3 August 2009 1,3 Fuji Synapse 3.2.X 13 August 2008 1 GE Healthcare Centricity PACS 4.0 SP3 1 August 2014 GE Healthcare Centricity Cardiology Enterprise 5.x 16 July 2015 Intuitive ImageQube 12.0.1 16 February 2012 1 McKesson Horizon Medical Imaging 11.X 2 November 2010 1,4 McKesson McKesson Radiology 12.0 10 December 2013 McKesson McKesson Cardiology 13.x 11 May 2015 Merge Merge PACS 6.5 27 April 2012 1 NovaRad NOVAPACS 1.2 6 June 2014 Philips iSite 4.2 24 April 2009 2 Philips IntelliSpace 4.x 29 November 2011 1,5 Philips IntelliSpace Cardiovascular FD20 12 December 2018 ScImage PicomEnterprise 3.x 23 March 2015 Siemens Syngo Dynamic Server VA10 17 June 2015 Siemens Syngo Plaza VB20 9 Sept 2016 Siemens syngo dynamics VA20 28 December 2016 http://www.va.gov/health/IMAGING/docs/VistA_PACS_HL7_Profile_1_2.pdf
Key to Notes
1. Patient location is updated real time.
2. Patient location is recorded and indicated as being that at the time of the order.
3. Product has neither asserted support for, nor been validated for, report message processing and storage.
4. Most recently tested version is 11.7.
5. Most recently tested version is 4.4.
6. Required to use the VA MWL SCP