Attachment A 36C24823Q0071

C.W. Bill Young VA Medical Center Bay Pines, FL 33744

Turnkey Security - Brand Name or Equal *** Reference manufacturer – Avigilon ***

Statement of Work

I. Scope of Work:

The contractor shall provide a Turnkey Solution – Brand Name or Equal for a fully functional, License Plate Camera (LPC) system that has coverage of the two entrances (Main Entrance and East Entrance totaling eight lanes) to the CW Bill Young Medical Center (Main campus) and can be viewed from the Police Communications Center at the Main campus. The system should include at a minimum the following:

A. Five (5) Avigilon Brand Name or Equal license plate cameras with IR illuminators and all mounting hardware for large pole and outdoor use.

B. Eight (8) Avigilon Control Center 7 (ACC7.x) Brand Name or Equal software licenses for the eight (8) lanes to be monitored.

C. All hardware and cabling needed to connect the cameras to the existing CCTV network. All network equipment must be Cisco Enterprise compatible.

1. Existing fiber at main entrance and east entrance, will need to be extended depending on proper location of cameras.

The contractor shall program the LPCs for viewing by the VA Police Communications Center located at the main campus. Training shall be provided as needed for end users and maintenance technicians.

Contractor shall provide a project manager for oversight of installation and programming and to act as a central Point of Contact for questions or concerns with performance of work.

II. QUALFICATIONS:

A. Contractor shall have two years documented experience in installing and servicing similar facilities and shall be approved by the government.

B. The installer must be certified by the manufacturer to perform electronic hardware installation and integration and must provide written verification of certification from the manufacturer.

III. MAINTENANCE

A. Contractor must have warranty/service technician within daily commuting distance of Bay Pines VA Healthcare System. Technician must meet qualifications listed above.

IV. WARRANTY

A. Standard Warranty

1. Two-year standard warranty on all materials unless otherwise noted within requirements specifications

2. One-year standard warranty on all labor performed

B. Copies of the warranties must be provided to the owner upon substantial completion with the dates of warranty coverage noted.