S02 - ATTACHMENT 1 SOW-Rapid CityPkg. 04- Equip Rails.docx
DOCX document 141 KB Posted
- Attached to
- 6530--Rapid City Pkg. 4 - Rails
- Solicitation number
- 36C77623Q0108
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 - Amendment 36C77623Q0108 0001-Rapid City Pkg. 04-Equipment Rails (1).docx | DOCX document | |
| S02 -ATTACHMENT 2 - RFQ - Buy American Certificate 6.4.21.docx | DOCX document | |
| 36C77623Q0108.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rapid City
Package # 004 - Equipment Rails Statement of Work
1.9.23 Rev. 3
VA Black Hills Health Care System (VA BHHCS) Rapid City Community Based Outpatient Clinic (RCCBOC)
Introduction The Rapid City, SD CBOC has a requirement to purchase an Equipment Rails with an authorized vendor to supply and deliver the item(s) identified in Table 1 below. This requirement is in support of a brand name or equal requirement. See FAR Clause 52.211-6 – Brand Name or Equal (AUG 1999) for additional information. See below for salient characteristics. This requirement is in support of the activation of the VA BHHCS Outpatient Clinic. Item(s) are to be delivered to the location specified in section 2.4.1. The basis of design is Nexxspan.
Table 1 – Package Items Summary
| CLIN # |
| DESCRIPTION |
| JSN |
| Quantity |
| 0001 |
| Rail, Accessory Mounting, approx. 2' length MFG: Nexxspan- Part #1002-024 (Brand Name or Equal) |
| A1132A |
| 11 |
| 0002 |
| Rail, Accessory Mounting, Length 4' |
MFG: Nexxspan- Part #1002-048(Brand Name or Equal)
| A1132 |
| 78 |
| 0003 |
| Holder, Rail Mount Adapter for narrow and wide soap, sanitizer and lotion dispensers (Universal) MFG: Nexxspan- Part #1013-209 (Brand Name or Equal) |
| -- |
| 20 |
| 0004 |
| Holder, Bowman 3 Glove Box Rack, PN (1) GL033-0613, For Horizontal Rail Mount (Glove box not Included) MFG: Nexxspan- Part #1013-218 (Brand Name or Equal) |
| -- |
| 56 |
| 0005 |
| Rail Mount, BD Recykleen Cabinet Sharps, Model #305096 MFG: Nexxspan- Part #1013-097 (Brand Name or Equal) |
| -- |
| 36 |
| 0006 |
| Mounting Kit, Welch Allyn Tycos-Aneroid Manometer, Model 767 MFG: Nexxspan- Part #1012-P05 (Brand Name or Equal) |
| -- |
| 32 |
| 0007 |
| Mounting Plate, Connex SPOT Monitor, Rail Mount MFG: Nexxspan- Part #1013-165 |
| -- |
| 32 |
| 0008 |
| Holder, Ophthalmoscope/Otoscope, Welch Allyn 767 Series MFG: Nexxspan- Part #1013-0011 (Brand Name or Equal) |
| -- |
| 32 |
| 0009 |
| Basket, Fixed, 18“ Wide x 9” Deep x 4“ High, W/3 Dividers (option for sitting the Aspirator inside). MFG: Nexxspan- Part #1011-003 (Brand Name or Equal) |
| -- |
| 4 |
| 0010 |
| Installation |
| N/A |
| 1 |
General Conditions Site Address The address of the Rapid City VA Outpatient Clinic is listed below. Additional information on delivery is located in section 2.4.
Rapid City VA OPC 2165 Promise Road Rapid City, SD 57701
Delivery Schedule Items shall be delivered no earlier than the estimated delivery start date and no later than the delivery end date listed in Table 2 below.
Table 2 – Anticipated Building Outfitting Schedule
| Building Name |
| ITEMS-COORDINATION |
| Acronym |
| Est. Delivery Start Date |
| Est. Delivery End Date |
| Rapid City VA Outpatient Clinic |
| Equipment Rails |
| RCCBOC |
| 04/11/2023 |
| 04/30/2023 |
Schedule and Order Management The above delivery schedule is based upon the current construction schedule, which is subject to change. The vendor shall not increase prices for a change in delivery date for up to 90 days due to construction delays.
The awardees actual delivery dates will be confirmed by VA upon award.
Post-award the vendor will coordinate delivery prior to beginning any work (see section 2.4). Once the dates have been confirmed, modifications to the schedule are subject to written approval by the VA POC. Schedule changes that are beyond the dates specified in the contract will require approval by the Contracting Officer and a contract modification.
Delivery and Receiving Delivery and receipt of the proposed items is anticipated to be directed to the location identified below. Confirmation of delivery location will be provided by the VA POC post-award. Delivery must be coordinated with VA Logistics POC Wesley Walker (Office); 605-720-7452 or Emily Apland (Office) 605-720-7427 prior to any attempts at delivery. Any item that has not been coordinated will be turned away and any additional charges will be the responsibility of the sender/transportation company. Vendor responsible for conducting a site visit to verify logistics and loading dock access/egress.
☒ Rapid City VA Outpatient Clinic 2165 Promise Road Rapid City, SD 57701 ☐ Rapid City VA Off-Site Activation Warehouse
TBD
Delivery shall be freight on board (FOB) – Destination.
The vendor is required to define the need for a staging area to accommodate item delivery, if needed. Post-award, this information will be confirmed with the vendor.
The delivery of items identified in this document shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Mountain Time), Monday through Friday, and excluding Federal Holidays.
Delivery trucks will not be permitted to remain at the loading dock. Trucks shall be unloaded by the vendor, moved from the dock, and then brought back to the dock if required to haul out any waste, tools, or excess materials.
Labeling of delivered items shall include the awarded contract number and VA purchase order number for identification and reference upon receipt of product.
2.4.7 Delivery and Installation includes:
Offloading the equipment from the truck, moving the equipment to the correct delivery location in the space, uncrating or unboxing the equipment and removing all trash, setting up the equipment according to the manufacturers specification and testing the equipment to verify that it is operational. Equipment installation paperwork & warranty information must be handed to the approved government contact onsite. See Sections 2.8, 2.9, & 2.10 below Clean Up and Disposal There are no dumpsters available for vendor use.
The removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.
Deliverables
2.6.1 ☐ Network Required if Checked ☒-Manufacturer Certified Installation Required if Checked ☐-BMET Training Required if Checked ☐-End User Training Required if Checked Assembly and Installation [ ☒ is ☐ is not ] required.
The vendor is required to manage and coordinate installation at the RCVAHC with the VA POC.
Installation and assembly shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Mountain Time), Monday through Friday, and excluding Federal Holidays.
The vendor is required to define the need for a staging area to accommodate item assembly and installation, if needed. Post-award, this information will be confirmed with the vendor.
The vendor is required to provide tools, labor and materials to complete assembly and installation of the items detailed in this document.
The vendor shall protect all finished spaces and surfaces as required from delivery and installation damage. The vendor shall use covering and protection to the extent necessary to prevent damage to finished spaces. Any damage occurred during delivery and installation is the responsibility of the vendor. The vendor will be responsible for paying for and repairing any damage or noted deficiencies to finished spaces and surfaces that occur as a result of the vendor’s (or associated sub-contractors) installation.
During the entire duration of assembly and installation, the vendor will have a competent representative on-site as the vendor’s contact, and to serve as the interface between the vendor and RCVAHC. On-site representative can be the installer. All instructions provided from COR to the representative will be binding as if given to the vendor’s main contact. The COR may provide specific instructions, however, only the Contracting Officer may change the terms or conditions of the contract.
Training [ ☐ is ☒ is not required] Standard Warranty The products shall be covered by vendor’s standard warranty terms and provisions. Vendors to provide their standard warranty information in their proposals. It should be noted however that the warranty coverage shall be no less than 1 YEAR.
The warranty period set forth therein shall be for one year following Receipt and Acceptance by the VA POC at the new Rapid City, SD (RCVAHC).
The vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the manufacturer.
The vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor’s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid therefor); and The vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.
Use of Premises If during the performance of this contract, work will be carried out on RCVAHC premises, the vendor shall perform all work in such a manner that will cause a minimum interference with RCVAHC operations and the operations of other contractors on the premises.
The vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor (GC) prior to and during delivery and installation activities.
The project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors’) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).
The vendors shall abide by all rules and regulations set forth by the CDC & the RCVAHC due to the Coronavirus (COVID-19) and have their own personal protective equipment (PPE) in use for the time they are on the GLA campus grounds.
2.11 Salient Characteristics
ITEM NAME: CLIN 0001
Rail, Accessory Mounting, approx. 2' length [JSN A1132A] MFG: Nexxspan- Part #1002-024 (Brand Name or Equal)
Salient Characteristics:
Dimensions: D 2.00 in W 24.00 in H 2.00 in D 50.8 mm W 609.6 mm H 50.8 mm
· Horizontal equipment mounting rail with lock mounting devices capable of; supporting up to 75 pounds each, being repositioned, and mounting and dismounting of equipment without the use of tools (special tools may be required to unlock adapter that was previously locked to the rail).
· The rail must be capable of supporting medical equipment and accessories normally found in exam or patient rooms.
· The rail system must be capable of mounting and dismounting equipment without leaving or creating new holes in the finished surface of the wall.
· The rail system utilizes a series of mounting plates and adapters specific to the device being mounted to the rail. The plate and adapter rail mounting kit must be specified to match the equipment being mounted to the equipment rail.
Department, Room, (Quantity)
Audiology and Speech Pathology Office, Therapy Room, Audologist-1803(1), Office, Therapy Room, Audologist-1804(1)
EMS
HAC-1724(1), HAC-1725(1), HAC-1726(1), HAC-1727(1), HAC-1728(1)
Mental Health Med Prep-1405A(1)
Pathology Core Lab One-1309(2)
Specialty Care Chart Room-1614(1)
Item Name: CLIN 0002 Rail, Accessory Mounting, Length 4’ [JSN: A1132] MFG: MFG: Nexxspan- Part #1002-048(Brand Name or Equal) Salient Characteristics:
Dimensions: D 2.00 in W 48.00 in H 2.00 in D 50.8 mm W 1219.2 mm DC: No ED: No
· Horizontal equipment mounting rail with lock mounting devices capable of; supporting up to 75 pounds each, being repositioned, and mounting and dismounting of equipment without the use of tools (special tools may be required to unlock adapter that was previously locked to the rail).
· The rail must be capable of supporting medical equipment and accessories normally found in exam or patient rooms. The rail system must be capable of mounting and dismounting equipment without leaving or creating new holes in the finished surface of the wall.
· The rail system utilizes a series of mounting plates and adapters specific to the device being mounted to the rail.
· The plate and adapter rail mounting kit must be specified to match the equipment being mounted to the equipment rail.
· Made in USA
· Available in white patent-pending Anti-Microbial powder-coat finish, a standard anodized aluminum finish, or customized in a variety of powder-coat colors.
· Lock-down adapter mechanism ensuring that mounted items and expensive equipment stays put until unlocked by authorized personnel Hang anything, anywhere.
· Capability to attach clinical and infection control devices to the equipment rail, vertical GCX channel, or IV pole.
· Rail comes standard with ANY color of Wilsonart laminate inlay. Other laminates available for additional price and lead time.
· The rail system utilizes a series of mounting plates and adapters specific to the device being mounted to the rail. The plate and adapter rail mounting kit must be specified to match the equipment being mounted to the equipment
· Wilsonart finish or equivalent : Color screenshot(s) or Manufacturer color brochure showing finish is to be provided with RFQ response.
· Physical finishes SAMPLE(S) will be Required of awardee upon award.
Samples shall be sent to:
Ms. Carissa Alley VA Black Hills Health Care system (BHHCS) 113 Comanche Road Fort Meade, SD 57741
Department, Room, (Quantity)
Mental Health Bariatric Exam-1406(2), Exam/Treatment Room-1407(2), RTMS Room-1418(1), Biofeedback Treatment Room-1419(1)
PACT
Exam Room, Bariatric, PACT-1501(2), Exam Room, PACT-1502(2), Exam Room, Womens Health-1503(2), Womens Health Exam Room-1506(2), Exam Room, PACT-1507(2), Med Prep Room-1508(1), Tele-Health Room-1518(2), Tele -Spirometry Room-1519(2), Procedure Room-1523(2), Exam Room, PACT-1524(2), Exam Room, PACT-1525(2), Exam Room, PACT- 1526(2), Exam Room, PACT-1527(2), Physical Therapy Room-1534(1), Physical Therapy Room-1535(1), Chiropractic Room-1545(1), Med Prep Room-1548(1), Exam Room, PACT-1549(2), Exam Room, PACT-1550(2), Exam Room, PACT- 1551(2), Procedure Room-1552(2), Exam Room, Womens Health-1568(2), Exam Room, Womens Health-1571(2), Exam Room, Womens Health-1572(2), Exam Room, Womens Health-1575(2), Exam Room, PACT-1576(2)
Pathology Blood Draw-1301(1), Blood Draw-1302(1), Blood Draw-1303(1)
Radiology Dressing Room-1903(1), Soiled Utility-1906(1), Radiology Room-1910(1)
Speciality Care Exam Room-1602(2), Exam Room-1603(2), Nurses Station-1604(1), Exam Room-1605(2), Exam Room-1606(2), Exam Room-1607(2), Exam Room-1608(2), Procedure Room-1611(2), Exam Room-1612(2), Procedure Room-1616(2)
Item Name: CLIN 0003 Holder, Rail Mount Adapter for narrow and wide soap, sanitizer and lotion dispensers (Universal) MFG: MFG: Nexxspan- Part #1013-209 (Brand Name or Equal Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
Item Name: CLIN 0004 Holder, Bowman 3 Glove Box Rack, PN (1) GL033-0613, For Horizontal Rail Mount (Glove box not Included) MFG: MFG: Nexxspan- Part #1013-218 (Brand Name or Equal Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
Item Name: CLIN 0005 Rail Mount, BD Recykleen Cabinet Sharps, Model #305096 MFG: MFG: Nexxspan- Part #1013-097 (Brand Name or Equal) Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
Item Name: CLIN 0006 Mounting Kit, Welch Allyn Tycos-Aneroid Manometer, Model 767 MFG: MFG: Nexxspan- Part #1012-P05 (Brand Name or Equal) Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
Item Name: CLIN 0007 Mounting Plate, Connex SPOT Monitor, Rail Mount MFG: MFG: Nexxspan Part #1013-165 (Brand Name or Equal) Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
Item Name: CLIN 0008 Holder, Ophthalmoscope/Otoscope, Welch Allyn 767 Series MFG: MFG: Nexxspan- Part #1013-0011 (Brand Name or Equal) Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
| Item Name: | CLIN 0009 | |
| Basket, Fixed, 18“ Wide x 9” Deep x 4“ High, W/3 Dividers |
(option for sitting the Aspirator inside).
MFG: MFG: Nexxspan- Part #1011-003 (Brand Name or Equal) Salient Characteristics:
Must be able to mount/hold identified item to mounting rail.
image1.jpeg
File details come from the government source that posted it. Updated .