PROJECT BOUNDARY
AREA FOR REMOVAL OF ASBESTOS-CONTAINING FLOORING
AND ASSOCIATED MASTIC
A. HAZMAT REMOVAL NOTES APPLY TO ENTIRE ROOMS. REMOVE ACCORDING
TO SAFETY STANDARDS. REFERENCE SPECIFICATION 02 82 11.
B. ALL HAZARDOUS MATERIALS SHALL BE REMOVED IN COMPLIANCE WITH
APPLICABLE CODES AND LAWS.
C. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE HAZARD(S) AND LEVEL
OF PROTECTION REQUIRED FOR ALL EMPLOYEES OR SUBCONTRACTORS
TO COMPLETE THE CONSTRUCTION WORK.
D. PROVIDE ABATEMENT OF VCT AND FLOORING MASTIC WITHIN HATCHED
AREA.
E. ALL FLOORING WILL REQUIRE ABATEMENT INCLUDING BUT NOT LIMITED TO
ALL 9X9 OR 12X12 VCT OR CERAMIC TILES.
F. PROVIDE COST FOR REMOVAL OF COUNTED AND UNFORESEEN MUD
FITTINGS ON FIBEGLASS INSULATED DOMESTIC WATER LINES. ASSUME 300
PLUMBING FITTINGS BETWEEN 1.5 INCH AND 6 INCH DIAMETER. PLUMBING
FITTING FOR ABATEMENT ARE LOCATED ON 7TH FLOOR AND CEILING OF
6TH FLOOR.
G. PROVIDE COST FOR REMOVAL OF COUNTED AND UNFORESEEN MUD
FITTING ON FIBERGLASS INSULATED PERIMETER HEATING AND COOLING
WATER LINES. ASSUME 300 HVAC PIPING FITTINGS BETWEEN 1.5 INCH AND 6
INCH DIAMETER. HVAC PIPING FITTINGS FOR ABATEMENT ARE LOCATED
PRIMARILY IN CEILING OF 6TH FLOOR AND ARE ASSOCAITED WITH EACH OF
THE WINDOW CABINET UNITS.
H. PROVIDE COST FOR REMOVAL OF ASBESTOS CONTAINING CABINET UNIT
HEATER BOXES. INSIDES OF UNITS ARE COATED WITH ACM. QUANITY 26.
I. PROVIDE COST FOR REMOVAL OF ASBESTOS CONTAINING 9X9 LVT, TILE
AND MASTIC, ASSUME 9,020 SF.
J. PROVIDE COST FOR REMOVAL OF ASBESTOS CONTAINING 4X4 WALL TILE,
MASTIC AND GROUT, ASSUME 1,816 SF.
K. PROVIDE COST FOR REMOVAL OF ASBESTOS CONTAINING 4X4 / 8X4 WALL
TILE BASE, ASSUME 132 LINEAR FEET.
L. PROVIDE COST FOR REMOVAL OF FLOURESCENT LIGHT TUBES AND CFL
BULBES, ASSUME 350 TOTAL.
M. PROVIDE COST FOR REMOVAL OF PDB CONTAINING BALLASTS FOR
FLUORESCENT LIGHTING FIXTURES, ASSUME 175 EACH.
N. BASED ON THE DATE OF THE EXISTING CONSTRUCTION AND
UNDERSTANDING OF THE FACILITY, LEAD PAINT IS WITHIN THE PROJECT
AREA. DO NOT PROVIDE LEAD PAINT ABATEMENT. CONTRACTOR TO
PERFORM DEMOLITION ACTIVITIES AFTER IMPLEMENTATION OF LEAD
STABILIZATION. CONTRACTOR TO USE MEASURES FOR PROTECTION AND
TO MINIMIZE PAINT DEBRIS.
1. DOMESTIC WATER RISERS
2. HVAC PIPING RISER
3. 4"X4" VERTICAL ASBESTOS-CONTAINING TILES AROUND SINK
HAZARDOUS MATERIAL REMOVAL GENERAL NOTES
HAZARDOUS MATERIAL REMOVAL PLAN NOTES
HAZARDOUS MATERIAL REMOVAL LEGEND
BEYOND PROJECT BOUNDARY
AREA FOR REMOVAL OF VERTICAL 4X4 ASBESTOS-CONTAINING
TILES
UP
1 1 1
1 1 1
2 2 2 2
33 33
PROJECT AREAA
B
C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT FOR
CONSTRUCTION
HA101
HAZARDOUS MATERIAL REMOVAL
PLANGUIDON DESIGN INC.
1221 N. Pennsylvania St.
Suite 200 Indianapolis, Indiana 46202 317.800.6388
RING & DUCHATEAU, LLP.
17400 W. Capital Drive Brookfield, WI 53045
414.778.1700
RENOVATE 7AN FOR
ENDOSCOPY LAB
5000 W National Ave, Milwaukee, WI 53295
695-19-107
08/21/2020 AWS DV
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"HA101
1 SEVENTH FLOOR PLAN HAZMAT ABATEMENT PLAN
Revisions: Date:
SCALE: 1" = 100'-0"
KEY PLAN
ACCOMPANYING SOLICITATION 36C25221Q0190