S02 36C24W25Q0275 Sources Sought Opportunities.pdf
PDF 162 KB Posted
- Attached to
- Patient Lift
- Solicitation number
- 36C24W25Q0275
- Issued by
-
Department of Veterans Affairs
About this file
This Sources Sought Notice is issued by the Department of Veterans Affairs (VA) for the Oklahoma City VA Healthcare System to procure two portable full body patient lifts for the new N Portland Clinic's Women's Health area. The specific requirement is for Arjo Maxi Move lifts (or equivalent), with detailed technical specifications including a 500 lb maximum safe working load, 1575 mm maximum lifting height, and 24V 4Ah battery. The lifts are needed to comply with the VA's Safe Patient Handling and Mobility Program, which prohibits manual lifting of patients over 35 pounds.
The solicitation number is 36C24W25Q0275, with responses due by July 18, 2025 at 12:00 PM Central Time. The procurement is classified under NAICS code 339113 (Surgical Appliance and Supplies Manufacturing) with a size standard of 800 employees. Potential vendors must submit a capabilities statement including company details, point of contact information, past performance evidence, and socioeconomic status. Responses should be emailed to the contract specialist, Robert M. Clark Jr., and will be used to determine potential sources for a future solicitation, with no guarantee of contract award.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
*= Required Field Sources Sought Notice
SUBJECT* Women's Clinic Patient Lift OKC | 635
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE* 95652
SOLICITATION NUMBER* 36C24W25Q0275
RESPONSE DATE/TIME/ZONE 07-18-2025 12:00pm CENTRAL TIME, CHICAGO, USA
ARCHIVE 99 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS N
SET-ASIDE
PRODUCT SERVICE CODE* 9999
NAICS CODE* 339113
CONTRACTING OFFICE ADDRESS Department of Veterans Affairs
Regional Procurement Office West (RPOW)
3237 Peacekeeper Way
Building 200 Suite 204
McClellan Park CA 95652
POINT OF CONTACT*
Contract Specialist
Robert M. Clark Jr robert.clark15@va.gov
254-538-0487
PLACE OF PERFORMANCE
ADDRESS Department of Veterans Affairs
Oklahoma City VA Healthcare System
Surgical Intensive Care Unit (SICU)
921 NE 13th Street
Oklahoma City OK
POSTAL CODE 73104
COUNTRY USA
ADDITIONAL INFORMATION
AGENCY’S URL http://www.va.gov
URL DESCRIPTION Department of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS robert.clark15@va.gov
EMAIL DESCRIPTION
DESCRIPTION
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR
PROPOSAL.
Disclaimer
This Sources Sought is issued solely for the purpose identifying potential sources for a future requirement and does not constitute a solicitation. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate.
All information received in response to this notice will be treated as proprietary and will not be shared with other interested parties. Responders are solely responsible for all expenses associated with responding to this Sources Sought notice. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. This Sources Sought Notice does not obligate the Government to award a contract.
Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
Synopsis
This is not a solicitation announcement. This is a Sources Sought synopsis only with the purpose of gaining knowledge of potential qualified sources and their size classification relative to the appropriate North American Industry Classification System (NAICS) 339113, Surgical
Appliance and Supplies Manufacturing (Size Standard: 800 employees). Responses to this
Sources Sought synopsis will be used by the Government to make appropriate acquisition decisions and are not considered adequate responses to a potential future solicitation announcement. After reviewing all responses to this synopsis, a solicitation announcement may be published via the Contracting Opportunities website. Responses to this Sources Sought synopsis are not considered adequate responses to the anticipated solicitation announcement. All interested offerors will have to respond to the actual solicitation announcement, in addition to responding to this Sources Sought announcement.
The Department of Veterans Affairs is requesting the following information be provided below:
Company Name:
Address:
UEI (Unique Entity ID) Number:
Contact Name:
Phone No.:
Email:
Product Country of Origin:
Business Size Information - Select all that applies:
Small Business
Emerging Small Business
Small Disadvantaged Business
Certified under Section 8(a) of the Small Business Act
HUBZone
Woman Owned
Certified Service-Disabled Veteran Owned Small
Veteran Owned Small Business
Large Business
FSS/GSA Contract Holder Yes No
FSS/GSA Contract Number:
Effective Date/ Expiration Date:
The description of service contained herein does not constitute the complete description of the contractor’s anticipated obligations. Interested parties capable of providing the required service are asked to respond to this Sources Sought notice.
Responses to this notice should include a capabilities statement to include the following:
1. Company name, Address, Size Standard, DUNS, Cage Code, TIN
2. Point of contact (Name, Phone Number and e-Mail Address)
3. NAICS Code 339113 and Business Standard MUST be assigned to the company
4. Socioeconomic Status
5. Capabilities Statement
a. Provide proof of past performance (provide proof of contracts that you have provided and installed or of the company who will be performing the installation).
b. Proof must be provided on the specific service in request.
c. If you will NOT be performing the work, you MUST provide information on the company you intend to use. In addition, you must provide a Letter of Intent from the company you intend to use (explaining their agreement with you to perform the installations according to the solicitation), along with references of their past installation service.
d. Past performance must not be negative in any previous contracts, based on the
Contract Performance Assessment System and the Contracting Officer’s knowledge of past requirements.
Responses
The government intends to award a single contract to purchase the services listed above.
Responses to this notice shall be e-mailed to robert.clark15@va.gov. Subject line shall reflect
“Sources Sought, 36C24W25Q0275, Patient Lift/your company name". Responses must be received no later than July 18, 2025, 12:00 P.M. EST.
Responses must be received via e-mail only. Telephone, fax, or mail responses will not be accepted. This notice is to assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Responses are not a request to be added to a prospective offeror’s list or to receive a copy of the solicitation.
End of Document
STATEMENT OF WORK
OKLAHOMA CITY VA HEALTH CARE SYSTEM
Brand Name or Equal
Background
The Oklahoma City VA Health Care System (OKC VAHCS) must purchase request 2 portable full body lifts for the new N Portland Clinic (Women’s Health). For continuity of care throughout the facility, we request Brand Name or Equal to Arjo Maxi Move lifts. This is the lift used exclusively in OKC VAHCS.
Objectives/Scope
The N Portland Clinic currently has no portable lifts for use in the clinical areas. We are a no lift facility.
Manual lifting of these patients is in direct violation of OKC VA MCP 118-20 “Safe Patient Handling and
Mobility Program.” This MCP states that no more than 35 pounds should be lifted by employees while doing patient care activities. This is necessary for patient care and patient/staff safety.
Selection Criteria
Quantity: 2
Manufacturer: Arjo Inc.
Model: Maxi Move
Maxi Move W/Scale, Standard Castors, No Spreader Bar (Brand Name or Equal)
Manufacturer: Arjo Inc.
Maxi Move 2-Point Loop Medium Combi Arched Spreader Bar (Brand Name or Equal)
Weight and Dimensions
Max safe working load kg 227 kg
Max safe working load lb 500 lb
Max safe working load if equipped with extended jib kg 130 kg
Max safe working load if equipped with extended jib lb 287 lb
Lifter weight (with spreader bar and battery) kg 70 kg
Lifter weight (with spreader bar and battery) lb 154 lb
Max lifting height 1575 mm
Max safe working load kg 227 kg
Max safe working load lb 500 lb
Max safe working load if equipped with extended jib kg 130 kg
Max safe working load if equipped with extended jib lb 287 lb
Lifter weight (with spreader bar and battery) kg 70 kg
Lifter weight (with spreader bar and battery) lb 154 lb
Max lifting height 1575 mm
Max lifting height in 62 in
Min lifting height 225 mm
Min lifting height in 8 ¾ in
Lifting stroke mm 1350 mm
Lifting stroke in 53,12 in
Min total storage height 1402 mm
Min total storage height in 55,25 in
External width legs closed mm 718 mm
External width legs closed in 28,25 in
External width legs open mm 1196 mm
External width legs open in 47,12 in
Internal width leg closed mm 578 mm
Internal width leg closed in 22,75 in
Internal width leg open mm 1074 mm
Internal width leg open in 42,25 in
Leg clearance (floor to top of legs) - standard castors mm
115 mm
Leg clearance (floor to top of legs) - standard castors in
4,5 in
Leg clearance (floor to top of legs) – low castors mm
101 mm
Leg clearance (floor to top of legs) – low castors in
4 in
Leg clearance (floor to top of legs) – extra low castors mm
57 mm
Leg clearance (floor to top of legs) – extra low castors in
2,25 in
Chassis clearance (floor to bottom of chassis) – standard & low castors mm
25 mm
Chassis clearance (floor to bottom of chassis) – standard & low castors in
1 in
Chassis clearance (floor to bottom of chassis) – extra low castors mm
19 mm
Chassis clearance (floor to bottom of chassis) – extra low castors in
0,75 in
Lifter length 1118 mm
Lifter length in 44 in
Turning diameter mm 1222 mm
Turning diameter in 48 in
Chassis clearance (floor to bottom of chassis) – standard & low castors in
1 in
Chassis clearance (floor to bottom of chassis) – extra low castors mm
19 mm
Chassis clearance (floor to bottom of chassis) – extra low castors in
0,75 in
Lifter length 1118 mm
Lifter length in 44 in
Turning diameter mm 1222 mm
Turning diameter in 48 in
Electrical:
Lifter protection class IPX4
Hand control protection class IPX7
Battery 24V 4Ah
Other Accessories: N/A
Delivery Schedule:
The equipment shall be delivered to the following address:
Oklahoma City VA Health Care System – Janice Stanfield for Marci Winningham/SICU
921 NE 13th Street
Oklahoma City, OK 73104
File details come from the government source that posted it. Updated .