This document provides details for a federal contract solicitation to relocate a pharmacy building at the Waco Veterans Affairs Health Care System. The solicitation number is 36C25721B0028 and seeks construction services to move Pharmacy operations to Building 15. The project value is estimated between $2 million to $5 million. This opportunity is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Offerors must be verified as SDVOSBs by the Department of Veterans Affairs Center for Verification and Evaluation prior to proposal submission. The point of contact for this project is Barbara Dustin of the Veterans Health Administration Veterans Integrated Service Network 17. A request for quote is expected to be posted on September 15, 2021.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 323113 Chain Link Fences and Gates.pdf | ||
| 36C25721B0028 0002.docx | DOCX document | |
| RFI questions_674A4-18-105Part2 10-27-21.docx | DOCX document | |
| 333000 Sanitary Sewer Utilities.pdf | ||
| 321216 Asphalt Paving.pdf | ||
| 331000 Water Utilities.pdf | ||
| 320523 Cement and Concrete for Exterior Improvements.pdf | ||
| RFI questions_674A4-18-105 PHARMACY.docx | DOCX document | |
| 36C25721B0028 0001.docx | DOCX document | |
| _SiteVisitSignIn_Lindeman.pdf | ||
| Bid Schedule1.docx | DOCX document | |
| 36C25721B0028_1.docx | DOCX document | |
| S02-21_06_30_VA Pharmacy Overall Plans_Part4.pdf | ||
| 21.08.17_VA Pharmacy-Addendum 1.pdf | ||
| S02-21_06_30_VA Pharmacy Overall Plans_Part2.pdf | ||
| S02-21_06_30_VA Pharmacy Overall Plans_Part1.pdf | ||
| 21_06_30_VA Pharmacy Specifications Overall.pdf | ||
| S02-21_06_30_VA Pharmacy Overall Plans_Part3.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEYED NOTES :
GENERAL NOTES:
LEGEND
V1-1 V1-4
V1-5 V1-6 V1-11 V1-12 V1-13 V1-16
V1-14
V1-10V1-9 V1-8V1-7
V1-3
V1-2
V1-17
V1-15
V2-1
V2-2
V2-3
V2-4 V2-5
RF-2
RF-1
EF-3
H-1
EF-1
FCU-1A
EF-6
FCU-1B
112 114
204 104
125A
H1 T-L1
H1L1
CKT 39
CKT 41
CKT 43
CKT 41 CKT 43
CKT 45
CKT 49
CKT 49
CKT 53 CKT 53
CKT 55
CKT L1-33
PRS
HX-1
HWP-1
HWP-2
CWP-1
CWP-2
CP-1
AHU-1
SG-1
EF-5
AHU-2
ET-2
AS-1
AS-2
ATS
1 2
ALL CIRCUITS SERVED FROM
PANEL 'L1' U.N.O.
E3.1
E8.1
143141
PRS
HX-1
HWP-1
HWP-2
CWP-1
CWP-2
CP-1
AHU-1
SG-1
EF-5
AHU-2
ET-2
AS-1 AS-2
H1L1 H1 T-L1
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
O 'C
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E3.1
ELECTRICAL POWER &
SIGNAL FLOOR PLANS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
3.
EL
EC
TR
IC
A L
PO
W
ER
S
IG
N A
L
FL
O O
R
PL
A N
S.
d w g sa ve d
/2
9/
:5 8:
P
M b y kp ha m p lo tte d
/3 0/
:4
0:
A M b y ki m p ha m
1 ELECTRICAL POWER & SIGNAL PLAN
SCALE: 1/8" = 1'-0"
2 ENLARGED MECHANICAL & ELECTRICAL ROOM
SCALE: 1/4" = 1'-0"
6/30/2021
112 114
204 104
125A
H1L1 T-L1
1 LIGHTING PLAN
SCALE: 1/8" = 1'-0"
H1-1
H1-3
H1-5
H1-17 H1-7
H1-9
H1-9
H1-9
KEYED NOTES :
GENERAL NOTES:
LEGEND
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E4.1
LIGHTING PLANS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
4.
LI
G
HT
IN
G P
LA
N
S.
d w g sa ve d
/2
9/
:5 7:
P
M b y kp ha m p lo tte d
/3 0/
:4
0:
A M b y ki m p ha m
112 114
204 104
125A
1 FIRE ALARM PLAN
SCALE: 1/8" = 1'-0"
FIRE ALARM
KEYED NOTES :
GENERAL NOTES:
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E5.1
SPECIAL SYSTEMS PLANS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
5.
SP
EC
IA
L
SY
ST
EM
S
PL
A
N S.
d w g sa ve d
/3 0/
:2
7:
A M b y kp ha m p lo tte d
/3
0/
:4 0:
A
M b y ki m p ha m
ONE-LINE LEGEND
PNL
H1
200A
PNL
L1
125A
1 EXISTING ONE-LINE DIAGRAM
SCALE: NTS
PNL
H1
200A
PNL
L1
125A
GENERATOR
ONE-LINE DIAGRAM
SCALE: NTS
AUTOMATIC TRANSFER SWITCH SCHEDULE
SWITCH SCHEDULE - ELECTRICAL CHARACTERISTICS AND FEATURES
TAG DESCRIPTION VOLTS PH SWITCHED AMPS BYPASS/ PROG ENCL NOTES
POLES (MIN) ISOLATION TRANSITION
ATS-E EMERGENCY 277/480 3 3 200 YES YES NEMA 1 1
SETTINGS
TAG DESCRIPTION SETTINGS
ATS-E NOTES
NORMAL SOURCE VOLTAGE PICKUP 95%
NORMAL SOURCE VOLTAGE DROPOUT 90%
ALTERNATE SOURCE VOLTAGE PICKUP 90%
ALTERNATE SOURCE FREQUENCY PICKUP 90%
TDES TIME DELAY TO ENGINE START 0.5 SEC
TDNE TRANSFER NORMAL TO EMERGENCY TIME DELAY 15 SEC
TDPT TIME DELAY PROGRAMMED TRANSITION DWELL 3 SEC
TDEN TIME DELAY RETRANSFER EMERGENCY TO NORMAL 30 SEC
TDEC TIME DELAY ENGINE COOLDOWN 15 MIN
ENGINE EXERCISER N/A 1
NOTES
1. PROGRAM FOR 15 MIN UNLOADED RUN TIME PER WEEK, TIME AND DAY AS DIRECTED BY OWNER.
ENGINE GENERATOR SET SCHEDULE
LOAD STEP DATA
LOAD RUNNING STARTING LOAD NOTES
NO. DESCRIPTION LOAD TYPE KVA KVA CYCLES
1A LIGHTING LIGHTING 10.8 10.8
1B HVAC EQUIPMENT 64.8 64.8 NO 1
1C RECEPTACLES GENERAL PURPOSE 36.3 36.3
1D RECEPTACLES REFRIGERATORS 25.9 25.9
INRUSH TOTALS - ALL LOADS 137.8
ATS 'E' (MAX)
LOAD STEP NOTES
1. HVAC CYCLES INDIVIDUALLY DURING OPERATION, TOTAL LOAD DOES NOT RUN COINCIDENTAL. RUNNING KW & KVA
SCHEDULED ARE FOR ENTIRE UNIT ON INITIAL STARTUP.
PROJECT SPECIFIC PERFORMANCE REQUIREMENTS - SEE SPECS FOR ADDITIONAL REQUIRMENTS
THE GENSET MUST MEET ALL OF THE FOLLOWING PERFORMANCE REQUIREMENTS WHILE OPERATING THE LOADS AS TABULATED ABOVE. SEE SPECIFICATIONS FOR METHODS OF DETERMINING COMPLIANCE WITH THE FOLLOWING REQUIREMENTS. SUBMITTAL DATA MUST INCLUDE ADEQUATE INFORMATION TO DEMONSTRATE COMPLIANCE WITH EACH OF THE FOLLOWING.
REQMT. REQUIREMENT REQUIRED
NO. DESCRIPTION PERFORMANCE
<1a> SITE AMBIENT OPERATING TEMPERATURE (OUTDOOR AMBIENT) 105 DEG F <1b> SITE AMBIENT OPERATING TEMPERATURE (INDOOR AMBIENT AT ALTERNATOR AIR INTAKE) 125 DEG F
2 MAXIMUM VOLTAGE DIP DURING FIRE PUMP LOAD PICKUP -
3 MAXIMUM VOLTAGE DIP DURING ANY REMAINING LOAD STEP PICKUPS 20%
4 MAXIMUM VOLTAGE DIP DUE TO CYCLICAL LOADS 10%
6 MAXIMUM FREQUENCY DIP DURING ANY LOAD STEP PICKUP 3 Hz 8 MAXIMUM FREQUENCY DIP DUE TO CYCLICAL LOADS 2 Hz 9 MAXIMUM FREQUENCY SKEW RATE DURING LOAD STEP PICKUP OR CYCLICAL LOAD PICKUP 2 Hz/Sec 10 MAXIMUM FREE FIELD NOISE AT 3 METERS 94 Dba
11 NOMINAL VOLTAGE OUTPUT 277/480V 3PH 4W
12 FUEL SOURCE #2 DIESEL
PROJECT SPECIFIC ACCESSORIES - SEE SPECS FOR ADDITIONAL REQUIRED ACCESSORIES AND FEATURES
WEATHERPROOF NON-SOUND ATTENUATING HOUSING REQUIRED
WEATHERPROOF SOUND ATTENUATING HOUSING NOT REQUIRED
SILENCER CRITICAL
DAY TANK NOT REQUIRED
BASE MOUNTED FUEL TANK 96 HOURS, UL 142
UNIT MOUNTED LOAD BANK 80% OF N.P. KW
UNIT MOUNTED CIRCUIT BREAKER 200/3
ACCESSORIES NOTES
ELECTRICAL LOAD ANALYSIS
CONNECTED LOAD
EXISTING SERVICE* 166 kVA
EXISTING LOAD* 77.3 kVA EXISTING LOAD REMOVED 70.0 kVA NEW LOAD ADDED 121.2 kVA
NET LOAD 51.2 kVA
THE EXISTING ELECTRICAL SERVICE REMAINS ADEQUATE FOR THE REVISED
LOAD.
* FROM RECORD DOCUMENTS DATED 2008.
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E6.1
ELECTRICAL RISER AND
SCHEDULES
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
6.
EL
EC
TR
IC
A L
RI
SE
R A
N D
S C
HE
D
UL
ES
.d w g sa ve d
/3 0/
:1
6:
A M b y kp ha m p lo tte d
/3
0/
:4 0:
A
M b y ki m p ha m
LIGHTING FIXTURE SCHEDULE
ID
DESCRIPTION MOUNTING
DRIVER
LUMENS VOLTS MANUFACTURER
CATALOG
NOTES
TAG NO.
A1 2'x4' TROFFER LAY-IN 0-10V 10% 4300L UNV ACUITY 2FGG43L-840-4-DS-UNV-DIM
4000K
36.2W OR APPROVED EQUAL
A2 2'x4' TROFFER LAY-IN 0-10V 10% 4800L UNV ACUITY 2FGG48L-840-4-DS-UNV-DIM 4000K
41W OR APPROVED EQUAL
D2 6" EXTERIOR DOWNLIGHT, WET LOCATION RATED SURFACE, CEILING ELEC UNV ACUITY EVO6-40/15-AR-MD-LS-MVOLT-GZ10
4000K GOTHAM
OR APPROVED EQUAL
S1 4' ENCLOSED STRIP SUSPENDED ELEC 4000L UNV ACUITY FSX440L840-UNV
4000K
32W OR APPROVED EQUAL
S2 8' ENCLOSED STRIP SUSPENDED ELEC 8000L UNV ACUITY FSX880L840-UNV
4000K
64W OR APPROVED EQUAL
V1 4' VANITY WALL, 7'-6" TO BOTTOM ELEC 2500 UNV ACUITY FMVTRL-48IN-MVOLT-30K-90CRI-BN 3000K
34W OR APPROVED EQUAL
W1 EXTERIOR WALL PACK, WET LOCATED RATED WALL, 8'-0" TO BOTTOM ELEC 5250L UNV ACUITY TWX2-P3-40K-MVOLT-PE 4000K
39W OR APPROVED EQUAL
X1 EXIT LIGHT SURFACE/WALL UNV ACUITY VERW 1
4000K
3W OR APPROVED EQUAL
GENERAL:
1 REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION.
REFERENCED NOTES:
1 PROVIDE FACES, MOUNTING, AND DIRECTIONAL ARROW CHEVRONS AS REQUIRED.
BC PNL 277/480 V 3PH 4W 200 A MCB 18 KAIC 42 CKT SURF MTD NEMA 1 1 SECT
H1 LOCATION: FED FROM:
CKT LOAD DESCRIPTION LOAD BREAKER CIRCUIT
NOTES PH
NO. TYPE TRIP / POLES SIZING
1 RM 201, 202, 203, 204 LTG 20 / 1 1#12, #12N, #12G, 3/4"C A
3 RM 205, 206, 207, 208 LTG 20 / 1 1#12, #12N, #12G, 3/4"C B
5 RM 100, 130, 131 LTG 20 / 1 1#12, #12N, #12G, 3/4"C C
7 RM 103, 109, 117, 121, 123 LTG 20 / 1 1#12, #12N, #12G, 3/4"C A
9 RM 101, 102, 104, 105, 106, 107, 108, 110, 111, 112, 113, 114, 115, 116, 118, 119,120, 122LTG 20 / 1 1#12, #12N, #12G, 3/4"C B
11 [XR] AHU-1 A/C 60 / 3 C
13 A 15 B
17 RM 124, 125, 125A, 126, 127, 128, 129 LTG 20 / 1 1#12, #12N, #12G, 3/4"C C
19 AHU-2 A/C 40 / 3 3#8, #10G, 3/4"C A
21 B 23 C 25 20 / 1 A 27 20 / 1 B 29 20 / 1 C
31 HWP-1 MOT 20 / 3 3#12, #12G, 3/4"C A
33 B 35 C
37 HWP-2 MOT 20 / 3 3#12, #12G, 3/4"C A
39 B 41 C
2 A 4 B
6 MECH RM ELEC RM LTG 20 / 1 1#12, #12N, #12G, 3/4"C C
8 [XR] POWER METER OTH 20 / 1 A
10 RF-1 MOT 20 / 3 3#12, #12G, 3/4"C B
12 C 14 A
16 RF-2 MOT 20 / 3 3#12, #12G, 3/4"C B
18 C 20 A
22 CHWP-1 MOT 20 / 3 3#12, #12G, 3/4"C B
24 C 26 A
28 CHWP-2 MOT 20 / 3 3#12, #12G, 3/4"C B
30 C 32 A
34 SPACE ONLY B
36 SPACE ONLY C
38 [XR] XFMR T-L1 FDR 70 / 3 A
40 B 42 C
NOTES:
BC PNL 120/208 V 3PH 4W 150 A MCB 10 KAIC 84 CKT SURF MTD NEMA 1 1 SECT
L1 LOCATION: FED FROM: H1
CKT LOAD DESCRIPTION LOAD BREAKER CIRCUIT
NOTES PH
NO. TYPE TRIP / POLES SIZING
1 ROBOT REC 30 / 3 3#10, #10N, #10G, 3/4"C A
3 B 5 C
7 RM 202 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
9 RM 203, 204, 207 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
11 RM 203, 205, 206, 208 + TV REC 20 / 1 1#12, #12N, #12G, 3/4"C C
13 RM 100, 130 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
15 RM 129 MOT 20 / 1 1#12, #12N, #12G, 3/4"C B
17 RM 125 REC 20 / 1 1#12, #12N, #12G, 3/4"C 1 C
19 COPIER REC 20 / 2 2#12, #12N, #12G, 3/4"C 1 A
21 1 B
23 COPIER REC 20 / 2 2#12, #12N, #12G, 3/4"C 1 C
25 1 A
27 RM 205 (REF.) KIT 20 / 1 1#12, #12N, #12G, 3/4"C 1 B
29 RM 205 (MCWV.) KIT 20 / 1 1#12, #12N, #12G, 3/4"C 1 C
31 RM 209 (COF.) KIT 20 / 1 1#12, #12N, #12G, 3/4"C 1 A
33 RM 108 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
35 RM 100, 103, 104, 127, 129 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
37 RM 101, 102 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
39 RM 105 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
41 RM 107, 108, 112 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
43 RM 114, 115 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
45 RM 116 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
47 RM 103, 104, 106, 110 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
49 RM 111, 113, 117 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
51 RM 120 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
53 RM 118, 119, 120 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
55 RM 122 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
57 [XR] CRAWL SPACE LTS OTH 20 / 1 1#12, #12N, #12G, 3/4"C B
59 [XR] FIRE ALARM CONTROL PANEL LTG 20 / 1 1#12, #12N, #12G, 3/4"C C
61 SECURITY PANELS OTH 20 / 1 1#12, #12N, #12G, 3/4"C A
63 SECURITY PANELS OTH 20 / 1 1#12, #12N, #12G, 3/4"C B
65 SECURITY PANELS OTH 20 / 1 1#12, #12N, #12G, 3/4"C C
67 SECURITY PANELS OTH 20 / 1 1#12, #12N, #12G, 3/4"C A
69 RM 205 (DISPOSAL) REC 20 / 1 1#12, #12N, #12G, 3/4"C B
71 RO SYSTEM OTH 20 / 1 1#12, #12N, #12G, 3/4"C C
73 20 / 1 A 75 20 / 1 B 77 20 / 1 C 79 20 / 1 A 81 20 / 1 B 83 20 / 1 C
2 WALL PACKS LTG 20 / 1 1#12, #12N, #12G, 3/4"C A
4 ETP, CP MOT 20 / 1 B
6 VAV WEST OTH 20 / 1 1#12, #12N, #12G, 3/4"C C
8 VAV EAST OTH 20 / 1 1#12, #12N, #12G, 3/4"C A
10 EF-1 MOT 20 / 1 1#12, #12N, #12G, 3/4"C B
12 EF-2 MOT 20 / 1 1#12, #12N, #12G, 3/4"C C
14 EF-3 MOT 20 / 1 1#12, #12N, #12G, 3/4"C A
16 EF-4 MOT 20 / 1 1#12, #12N, #12G, 3/4"C B
18 EF-5 MOT 20 / 1 1#12, #12N, #12G, 3/4"C C
20 EF-6 MOT 20 / 1 1#12, #12N, #12G, 3/4"C A
22 SPARE 20 / 1 B
24 EWH OTH 30 / 2 2#10, #10G, 3/4"C C
26 A
28 [XR] FIRE ALARM OTH 20 / 1 1#12, #12N, #12G, 3/4"C B
30 RM 123 (VEND.) REC 20 / 1 1#12, #12N, #12G, 3/4"C C
32 RM 123 (VEND.) REC 20 / 1 1#12, #12N, #12G, 3/4"C A
34 RM 123 (VEND.) REC 20 / 1 1#12, #12N, #12G, 3/4"C B
36 RM 123 (COF.) KIT 20 / 1 1#12, #12N, #12G, 3/4"C C
38 RM 123 KIT 20 / 1 1#12, #12N, #12G, 3/4"C A
40 RM 123 (MCWV.) KIT 20 / 1 1#12, #12N, #12G, 3/4"C B
42 RM 123 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C C
44 RM 123, 124 REC 20 / 1 1#12, #12N, #12G, 3/4"C A
46 RM 107 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
48 RM 107 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
50 RM 125 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C A
52 RM 125 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C B
54 RM 125 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
56 RM 125 COPIER REC 20 / 1 1#12, #12N, #12G, 3/4"C A
58 RM 125 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C B
60 RM 125 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C C
62 RM 125 (REF.) REC 20 / 1 1#12, #12N, #12G, 3/4"C A
64 RM 125 REC 20 / 1 1#12, #12N, #12G, 3/4"C B
66 RM 126 REC 20 / 1 1#12, #12N, #12G, 3/4"C C
68 RM 123 (DISPOSAL) REC 20 / 1 1#12, #12N, #12G, 3/4"C A
70 20 / 1 B 72 20 / 1 C 74 20 / 1 A 76 20 / 1 B 78 20 / 1 C 80 20 / 1 A 82 20 / 1 B 84 20 / 1 C
NOTES:
EQUIPMENT CONNECTION SCHEDULE
THIS SCHEDULE IS PROVIDED FOR SELECTED EQUIPMENT ONLY. SEE PLANS & SPECIFICATION REQUIRMENTS FOR ADDITIONAL ITEMS REQUIRING CONNECTIONS.
EQUIPMENT INFORMATION
CONTROLLER CONTROLLER DISCONNECT
TYPE
FURNISHED INTEGRAL
VOLTS
SIZE/ ENCL
TYPE
OCPD RATING
NOTES
TAG DESCRIPTION LOCATION W/ EQUIP BYPASS RATING TYPE (/TRIP)
EWH WATER HEATER JANITORS - YES 208/1 NEMA 1 SAFETY SWITCH NO FUSE 60
V1-x VAV CONTROLS QTY PER PLANS - YES 120/1 NEMA 1 MOTOR RTD SW 20
AHU-1 AIR HANDLING UNIT MECH RM - YES 480/3 NEMA 1 SAFETY SWITCH NO FUSE 60
AHU-2 AIR HANDLING UNIT MECH RM VFD YES 480/3 NEMA 1 INT W/ EQUIP
HWP-1 HEATING WATER PUMP VFD NO 480/3 5 HP NEMA 1 INT W/ VFD
HWP-2 HEATING WATER PUMP VFD NO 480/3 5 HP NEMA 1 INT W/ VFD
CHWP-1 CHILLED WATER PUMP VFD NO 480/3 5 HP NEMA 1 INT W/ VFD
CHWP-2 CHILLED WATER PUMP VFD NO 480/3 5 HP NEMA 1 INT W/ VFD
ETPx TRAP PRIMER QTY PER PLANS RELAY NO 120/1 NEMA 1 MOTOR RTD SW 20
CP CIRC PUMP RELAY NO 120/1 NEMA 1 MOTOR RTD SW 20
RF-1 RELIEF FAN VFD NO 480/3 10 HP NEMA 1 COMBINATION
RF-2 RELIEF FAN VFD NO 480/3 5 HP NEMA 1 COMBINATION
EF-1 EXHAUST FAN RELAY NO 120/1 NEMA 1 MOTOR RTD SW 20
EF-2 EXHAUST FAN STARTER NO 120/1 SIZE 0 NEMA 1 COMBINATION
EF-3 EXHAUST FAN STARTER NO 120/1 SIZE 0 NEMA 1 COMBINATION
EF-4 EXHAUST FAN STARTER NO 120/1 SIZE 0 NEMA 1 COMBINATION
EF-5 EXHAUST FAN RELAY NO 120/1 NEMA 1 MOTOR RTD SW 20
EF-6 EXHAUST FAN RELAY NO 120/1 NEMA 1 MOTOR RTD SW 20
XR AHU EXISTING TO REMAIN AHU MECH RM VFD NO 480/3 30 HP NEMA 1 COMBINATION
- ROLLUP DOOR - YES 120/1 NEMA 1 MOTOR RTD SW 20
REFERENCED NOTES:
GENERAL NOTES:
1. STARTERS ARE MAGNETIC, FULL VOLTAGE, NON-REVERSING U.N.O.
2. CONTROLLERS SHOWN AS FURNISHED WITH EQUIPMENT ARE INTEGRAL W/ EQUIPMENT U.N.O.
3. MINIMUM SHORT CIRCUIT INTERRUPTING & WITHSTAND RATINGS FOR ALL CONTROLLERS ON THE PROJECT SHALL MEET OR EXCEED THE SHORT CIRCUIT CURRENT AVAILABLE
AT THE UPSTREAM SUPPLY CIRCUIT'S OVERCURRENT PROTECTIVE DEVICE.
4. WHERE BRANCH CIRCUIT BREAKER IS SHOWN AS BEING UTILIZED AS CONTROLLER DISCONNECTING MEANS, PROVIDE THE BREAKER WITH PERMANENTLY INSTALLED HANDLE
LOCKOFF PROVISIONS.
5. NON-COMBINATION CONTROLLERS SHALL BE LOCATED BY PANELBOARD SERVING THE LOAD.
6. SINGLE POLE TOGGLE TYPE MANUAL STARTER WITHOUT OVERLOAD ELEMENTS, PROVIDE A SQUARE D CAT NO. FGJ1, OR EQUAL.
7. TWO POLE TOGGLE TYPE MANUAL STARTER WITHOUT OVERLOAD ELEMENTS, PROVIDE A SQUARE D CAT NO. FGJ2, OR EQUAL.
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E7.1
ELECTRICAL SCHEDULES
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
7.
EL
EC
TR
IC
A L
SC
HE
D
UL
ES
.d w g sa ve d
/3
0/
:1 2:
A
M b y kp ha m p lo tte d
/3 0/
:4
0:
A M b y ki m p ha m
2 GROUNDING BUSBAR
NOT TO SCALE 1 HANGER CLIP DETAIL
NOT TO SCALE
6 RACK ELEVATION
NOT TO SCALE
RACK TO RUNWAY
MOUNTING PLATE
NOT TO SCALE
5 ROOM ELEVATION
NOT TO SCALE
WALL ANGLE SUPPORT
AND J-BOLT
NOT TO SCALE
MENDEZ NGINEERINGE
Registration # F-14070 12950 Country Parkway, Suite 120 San Antonio, Texas 78216 Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
E8.1
ELECTRICAL DETAILS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\E le ct ric al \E
8.
EL
EC
TR
IC
A L
D
ET
A
IL
S.
d w g sa ve d
/3
0/
:3 9:
A
M b y kp ha m p lo tte d
/3 0/
:4
1:
A M b y ki m p ha m
7 ENLARGED IDF
PLUMBING ABBREVIATIONS PLUMBING GENERAL NOTES
CODE COMPLIANCE
PLUMBING SYMBOL SCHEDULE
HB
FPHB
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P1.1
PLUMBING SYMBOLS,
NOTES, & ABBREVIATIONS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
1.
PL
UM
BI
N
G S
YM
BO
LS
, N
O
TE
S, A
BB
RE
V
IA
TIO
N S.
d w g sa ve d
/2 9/
:4
2:
P M b y d jo hn so n pl ot te d
/2
9/
:4 3:
P
M b y d an ie l jo hn so n
6/29/2021
DEMO NOTES :
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
GENERAL NOTES:
PLUMBING DEMOLITION UNDERFLOOR PLAN
SCALE: 1/8" = 1'-0"
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P2.1
PLUMBING DEMOLITION
UNDERFLOOR PLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
2.
PL
UM
BI
N
G D
EM
O
LI
TIO
N P
LA
N
.d w g sa ve d
/2 9/
:4
1:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
DEMO NOTES :
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P2.2
PLUMBING DEMOLITION
PLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
2.
PL
UM
BI
N
G D
EM
O
LI
TIO
N P
LA
N
.d w g sa ve d
/2 9/
:4
1:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
GENERAL NOTES:
PLUMBING DEMOLITION PLAN
125A
KEYED NOTES :
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
GENERAL NOTES:
PLUMBING UNDER FLOOR PLAN
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P3.1
PLUMBING UNDERFLOOR
PLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
3.
PL
UM
BI
N
G U
N D
ER
FL
O O
R
PL
A N
.d w g sa ve d
/2 9/
:4
1:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
125A
3"FD2
3"FD2
3"FD2
4"FCO
3"FD2
EWH
MB
WCA
L1
HS
HS
P3.2
AFR
AFR
SK
AFR
IMB
SK
IMB
3"FD2
CP
DYCO
DYCO
DYCO
RO
KEYED NOTES :
L1
L1
L1
L1
WCA
WC
WC
WCA
WC
URA
HS
3"FD13"FD1
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
GENERAL NOTES:
PLUMBING FLOOR PLAN
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P3.2
PLUMBING FLOOR PLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
3.
PL
UM
BI
N
G F
LO
O
R
PL
A N
.d w g sa ve d
/2 9/
:4
0:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
PLUMBING ENLARGED FLOOR PLAN
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P5.1
PLUMBING SCHEDULES
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
5.
PL
UM
BI
N
G R
IS
ER
D
IA
G
RA
M S.
d w g sa ve d
/2 9/
:4
0:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
PIPING HANGERS AND SUPPORTS DETAIL
SOAP DISPENSER RPZ DETAIL
WALL HUNG WATER CLOSET
FLUSH VALVE PIPING SUPPORTS
CW PIPING
PIPING SUPPORT EQUAL
TO HOLDRITE #114-CO
WATER CLOSET FIXTURE CARRIER
FAUCET
HW CW
P-TRAP
SINK OR LAVATORY
PROVIDE AT ALL FIXTURES
WITH HOT AND COLD
3/8" COPPER
TUBING TYPICAL
POINT OF USE MIXING VALVE DETAIL (LAVATORY)
THERMOSTATIC MIXING
VALVE W / BRACKET
SUPPORT
REDUCED PRESSURE
ZONE VALVE ASSEMBLY DETAIL
COPPER PIPING UP IN WALL
REFER TO DRAWINGS FOR PIPE SIZE
TOP VIEW
WALL OR OBSTRUCTION
MAINTAIN A MIN. 24" CLEARANCE FROM OUTERMOST
DIMENSION ON SERVICE SIDE FOR SERVICE, TESTING
AND MAINTENANCE.
M
I N
M
I N
C L E
A R
A N
C E
COPPER PIPING UP IN WALL
REFER TO DRAWINGS FOR PIPE SIZE
CHROME SHALLOW SINGLE
PLATE ESCUTCHEONS,
TYPICAL.
M
I N
C L E
A R
A N
C E
FINISHED FLOOR OR OBSTRUCTION
SIDE VIEW
REDUCED PRESSURE ZONE VALVE ASSEMBLY WITH BRONZE
STRAINER, VERTICAL TEST COCKS AND CAPS.
PROVIDE AIR-GAP-FITTING, ROUTE DRAIN TO HUB DRAIN OR
1.
2.
NEAREST FLOOR DRAIN.
3. BACKFLOW PREVENTION DEVICES SHALL NOT BE INSTALLED ABOVE 5 FT AFF.
SINK OR LAVATORY PIPING SUPPORTS
STUD
STUD
DOMESTIC WATER PIPING
BRACKET EQUAL TO
HODRITE #SB2S
CLAMP EQUAL TO
HOLDRITE #250
WC1
FOR CLARITY REASONS, FLUSH VALVE ASSEMBLY,
SEATS, MOUNTING HEIGHTS, ETC. ARE NOT SHOWN
IN THESE VIEWS.
NOTE:
(SINGLE CARRIER
SUPPORT LEG
ANCHOR FOOT
ONLY, FASTNERS
SINGLE CARRIER
A R
C H
S
P
L A
N S
R E
F E
R
T
BY OTHERS)
NO-HUB VERT. STYLE CARRIER
NON-SHRINK
CAULK
SINGLE CARRIER-MOUNTED
WATER CLOSET FIXTURE SUPPORT
PLANS
SEE ARCHITECT'S
WC WC
PLANS
SEE ARCHITECT'S
FOR CLARITY REASONS, FLUSH VALVE ASSEMBLY,
SEATS, MOUNTING HEIGHTS, ETC. ARE NOT SHOWN
IN THESE VIEWS.
NOTE:
BACK TO BACK
LEG
SUPPORT
R E
F E
R
T
A R
C H
S
P
L A
N S
NO-HUB HORIZ. STYLE CARRIER
TYP. WALL
STUDS
WALL
FINISH
NON-SHRINK
CAULK
CARRIER-MOUNTED
WATER CLOSET FIXTURE SUPPORT
AUTOMATIC FLOW REGULATOR (AFR)
UNION
BALL VALVE
STRAINER
BALL VALVE
NOTE:
AT EACH AUTOMATIC FLOW ASSEMBLY, PROVIDE BALL
VALVES AND UNIONS UPSTREAM AND DOWNSTREAM,
LINE SIZED STRAINER, CHECK VALVE, AND
AUTOMATIC FLOW REGULATING VALVE.
AUTOMATIC FLOW REGULATOR ASSEMBLY DETAIL
CHECK VALVE
STOP WITH ROD NUT
(SEE SPECIFICATIONS)
A.W.W.A. BUILDING
REF: PLANS FOR SIZE
REINFORCED
24"x24"x6" THICK
CONCRETE PAD
BOX AND COVER MARKED
'WATER', TYLER SERIES
6500, WITH SCREWED LID
BUILDING WATER VALVE IN BOX
EXTERIOR
UNDISTURBED EARTH
"B-LINE" CORPORATION
B337CT RISER CLAMP SET
ON 1/4" THICK NEOPRENE
PAD
THUNDERLINE CORP.
6" SLEEVE WITH WATER-
STOP CAST IN PLACE.
SEAL ANNULAR SPACE W/
"LINK-SEAL" ASSEMBLY.
FINISHED FLOOR
FINISHED GRADE
BUILDING
WATER ENTRY DETAIL
TYPE 'K' COPPER PIPING. FOR PIPES
3" AND SMALLER PREFORM PIPING
USING A ROLLED RADIUS OF 12"
MINIMUM. USE 'IN-BLDG' RISER FOR
4" AND LARGER SERVICES. COAT
AND WRAP PIPING FOR
PROTECTION. EXTEND TREATMENT
TO 12" INSIDE THE BLDG. AND 12"
OUTSIDE THE BUILDING LINES.
WATER HEATER PIPING DETAIL
GWH
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P7.1
PLUMBING DETAILS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
7.
PL
UM
BI
N
G D
ET
A
IL
S.
d w g sa ve d
/2 9/
:3
9:
P M b y d jo hn so n pl ot te d
/2
9/
:4 4:
P
M b y d an ie l jo hn so n
CAST IRON DRAINAGE PIPE TRENCH DETAIL
NO HUB PIPE
BEDDING
HUB AND SPIGOT
PIPE BEDDING
THE TRENCH BOTTOM SHOULD BE STABLE ENOUGH TO SUPPORT THE
COMPLETE BARREL OF THE PIPE. IF POSSIBLE, THE BARREL OF THE PIPE
SHOULD REST ON EVEN AND UNDISTURBED SOIL.
IF THE DITCH MUST BE EXCAVATED DEEPER THAN THE DEPTH OF THE
DRAINAGE PIPE, PLACE AND TAMP BACKFILL MATERIAL TO PROVIDE
UNIFORM SUPPORT FOR THE PIPE BARREL.
HOLES SHOULD BE PROVIDED AT EACH JOINT
FOR EACH HUB OR COUPLING TO ALLOW FOR
CONTINUOUS SUPPORT OF THE BARREL
ALONG THE TRENCH BOTTOM.
BACKFILL
PLASTIC DRAINAGE PIPE TRENCH DETAIL
HAUNCHING
BEDDING
EMBEDMENT
AREA
6"
PIPE ZONE
SPRING LINE
INITIAL
EXCAVATED TRENCH
WIDTH
BACKFILL
FINAL
BACKFILL
WALL CLEANOUT DETAIL
CLEANOUT TEE
FINISHED WALL
STAINLESS STEEL ACCESS
COVER AND FRAME WITH
CLEANOUT PLUG
W/LEAD SEAL
COUNTERSUNK SCREWS
WALL HUNG WATER CLOSET
FLUSH VALVE PIPING SUPPORTS
CW PIPING
PIPING SUPPORT EQUAL
TO HOLDRITE #114-CO
WATER CLOSET FIXTURE CARRIER
BE PROVIDED WHERE INDICATED ON
THE DRAWINGS AND AS NECESSARY
TO PREVENT WATER HAMMER FROM
OCCURRING. A MINIMUM OF ONE
ARRESTOR SHALL BE PROVIDED FOR
EACH FIXTURE GROUP AND ON EACH
A GROUP FOR THIS REQUIREMENT
SERVICE TO THAT GROUP.
SHALL MEAN ONE OR MORE FIXTURES.
WATER HAMMER ARRESTORS SHALL
SIZED AND PLACED IN
ACCORDANCE WITH PDI
SERVICE LINE
BALL VALVE
STANDARD WH201.
NOTES:
WATER HAMMER ARRESTOR
WATER HAMMER ARRESTOR DETAIL
METAL STUD WALL
1 1/2"x 1 1/2"x 1/4", WELD TO METAL STUDS.
W/ (2) CARRIAGE BOLTS PER STRAP.
EXPANSION TANK,
CHARGING VALVE
2"x 1/8" GALVANIZED IRON STRAP
1/2" TO DOMESTIC WATER SYSTEM
8'-0" ± ABOVE FLOOR
WALL-MOUNTED EXPANSION TANK DETAIL
FLOOR CLEANOUT DETAIL
FINISHED FLOOR
TOP OF CLEANOUT TO BE
FLOW
CAULK AS REQUIRED
BALANCE OF PIPING SAME
AS CLEANOUT TO GRADE
LENGTH TO SUIT
ADJUSTABLE
ADJUSTABLE FLOOR CLEANOUT
COUNTERSUNK SCREW
PLUG AND SCORIATED COVER
SECURED TO PLUG WITH
SERVICE LINE, SEE
PIPE MATERIALS.
WYE FITTING
SPECIFICATIONS FOR
WITH INTERNAL BRONZE THREADED
GROUTED PLUG IN WYE FITTING
OR 1/8 BEND IF CLEANOUT OCCURS
AT END OF LINE
CLEANOUT TOP
FLUSH WITH FINISHED FLOOR
P-TRAP DETAIL
AT WASTE AND WATER WALL PENETRATIONS)
ESCUTCHEON WITH SET SCREW, (TYP.
POLISHED CHROME PLATED CAST BRASS
CHROME PLATED COVER
TUBE
2"x1-1/2", FOR
SINKS; SANITARY
TAPPED TEE
(REF. ARCH DWG'S).
CONSTRUCTION
WALL
NIBCO TYPE DWV
804 ADAPTOR
TYPE "L"
COPPER PIPE
1-1/2" VENT (MIN.)
REF. PLANS
2" WASTE, (MIN.),
VENT & WATER PIPING.
ROUTING OF WASTE,
FOR LOCATION AND
TYPE "L" COPPER PIPE
SUPPORT BRACKETS
SUMMER POSIFIX
NIBCO TYPE 604
ADAPTOR
PLATED P-TRAP
POLISHED CHROME
AND COPPER SUPPLYS (TYPICAL)
LOOSE KEY HANDLES WITH COVER
REPLACEABLE CARTRIDGE AND
HEAVY ANGLE STOP VALVE WITH
ADAPTOR
FLUSH TRAP
NIBCO TYPE 802
STRAINER
FLOOR DRAIN DETAIL - CAST IN PLACE
FINISHED
FLOOR
SUPPORT AT
THIS POINT
DEEP SEAL
"P" TRAP
CLAMP TO 24"x24"
4# LEAD SHEET AND
WATERPROOFING
REQUIRED FOR SINGLE
POUR CONSTRUCTION)
MEMBRANE (NOT
REQUIRED
CONCRETE FLOOR
OF TWO POUR
CONSTRUCTION
CAULK AS
ADJUSTABLE STRAINER,
DOUBLE DRAINAGE FLANGE
AND WEEP HOLES
RISER AND FITTINGS.
CONCRETE PAD.
IRON CLEANOUT HOUSING
WITH COUNTER-SUNK
GASKET SEAL BRONZE PLUG.
18"x18"x6" THICK
REINFORCED
6" THICK CONC. COLLAR.
2" CHAMFER ON ALL
FINISH GRADE, SEE SITE
DWG. FOR ELEVATIONS.
COLLARS IN EARTH.
LINE THRU 4" SIZE.
SERVICE LINE, SEE
SAME SIZE AS SERVICE
CAST IRON SOIL PIPE
4" MAX. SIZE REQ'D
PIPING MATERIALS
SPECIFICATIONS FOR
IRON CLEANOUT HOUSING
WITH COUNTER-SUNK
GASKET SEAL BRONZE PLUG.
95% COMPACTION,
SEE SPECIFICATIONS.
OPTION FOR END OF RUN
SINGLE AND DOUBLE YARD CLEANOUT DETAIL
HEATER
TO WATER
PUMP
STRAINER
FLOOR
TO FIN.
L
C
TO SYSTEM
AQUASTAT
HW CIRC. PUMP PIPING DETAIL
TEMP. GAUGE
WATER HEATER PIPING DETAIL
GWH
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
P7.2
PLUMBING DETAILS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\P lu m bi ng \P
7.
PL
UM
BI
N
G D
ET
A
IL
S.
d w g sa ve d
/2 9/
:4
2:
P M b y d jo hn so n pl ot te d
/2
9/
:4 5:
P
M b y d an ie l jo hn so n
FIRE PROTECTION NOTES
CODE COMPLIANCE
VALVES
HYDRANTS & YARD PIPING
GENERAL & AREA SPECIFIC SYMBOLS
OH2
SUPERVISORY & ALARM DEVICES
SPRINKLER HEADS
MISC. SYSTEM ACCESSORIES & APPURTENANCES
ALARM & SYSTEM VALVES
FIRE PROTECTION SERVICE
INTERRUPTION NOTES:
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
FP1.1
FIRE PROTECTION
SYMBOLS, NOTES, &
ABBREVIATIONS
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\F ire
\F P1
.1 F
IR
E
PR
O
TE
C
TIO
N
S
YM
BO
LS
, N O
TE
S, A
BB
RE
V
IA
TIO
N
S.
d w g sa ve d
/2
9/
:2 8:
P
M b y d jo hn so n pl ot te d
/2 9/
:4
3:
P M b y d an ie l jo hn so n
DEMO NOTES :
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
GENERAL NOTES:
FIRE PROTECTION DEMOLITION PLAN
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
FP2.1
FIRE PROTECTION
DEMOLITION PLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\F ire
\F P2
.1 F
IR
E
PR
O
TE
C
TIO
N
D
EM
O
LI
TIO
N
P
LA
N .d w g sa ve d
/2
9/
:2 8:
P
M b y d jo hn so n pl ot te d
/2 9/
:4
3:
P M b y d an ie l jo hn so n
125A
KEYED NOTES :
MENDEZ NGINEERINGE
Registration # F-14070
12950 Country Parkway, Suite 120
San Antonio, Texas 78216
Office: 210-802-0808 www.MendezEngineering.com
Austin 811 Barton Springs Road, Suite 900, Austin, Texas 78704 p: 512.478.7286 f: 512.478.7441 San Antonio 4040 Broadway, Suite 200, San Antonio, Texas 78209 p: 210.224.6032 f: 210.224.6453
100% SUBMITTAL
ENGINEERING FIRM:
O'CONNELL ROBERTSON
FIRM REGISTRATION NO. F-2708
GENERAL NOTES:
FIRE PROTECTION PLAN
O N
N
EL
L
RO
BE
RT
SO
N
, I N
C
FP3.1
FIRE PROTECTION
FLOORPLAN
06/30/21
H:
\1
9\
\3 T ec hn ic al
\D w gs \V
A W
A C
O P
HA
RM
A C
Y\ Sh ee ts
\F ire
\F P3
.1 F
IR
E
PR
O
TE
C
TIO
N
F
LO
O
RP
LA
N
.d w g sa ve d
/2 9/
:2
9:
P M b y d jo hn so n pl ot te d
/2
9/
:4 3:
P
M b y d an ie l jo hn so n
| 196900_CD_ELEC.pdf |
| Sheets and Views |
| E3.1 ELECTRICAL POWER & SIGNAL FLOOR PLANS |
| KEYED NOTES |
| ELECTRICAL GENERAL NOTES |
| E-NEW AND EXIST |
| ELEC PWR |
| V-E-01-ENLARGED |
| E4.1 LIGHTING PLANS |
| ELEC LTG |
| KEYED NOTES |
| ELECTRICAL GENERAL NOTES |
| E-NEW AND EXIST |
| E5.1 SPECIAL SYSTEMS PLANS |
| SPEC SYST |
| KEYED NOTES |
| ELECTRICAL GENERAL NOTES |
| E6.1 ELECTRICAL RISER AND SCHEDULES |
| RISER |
| E7.1 ELECTRICAL SCHEDULES |
| SCHEDULES |
| E8.1 ELECTRICAL DETAILS |
| ELEC DETAILS |
| V-E-ENLARGED IDF |
| 196900_CD_PLUMB.pdf |
| Sheets and Views |
| P1.1 PLUMBING SYMBOLS, NOTES, & ABBREVIATIONS |
| P1.1 |
| P2.1 PLUMBING DEMOLITION UNDERFLOOR PLAN |
| SCOPE |
| DNOTES |
| P2.2 PLUMBING DEMOLITION PLAN |
| SCOPE |
| DNOTES |
| P3.1 PLUMBING UNDERFLOOR PLAN |
| SCOPE |
| KNOTES |
File details come from the government source that posted it. Updated .