This document is a Business Sensitive maintenance requirements list for a naval vessel, detailing numerous repair and preservation tasks across multiple ship systems and compartments scheduled for completion between January 2027 and April 2027. The comprehensive list includes over 100 specific maintenance items covering areas such as air conditioning plant shells, flight deck tiedowns, ballast tanks, ventilation systems, machinery rooms, electrical systems, and deck coverings.
Key maintenance requirements include intrusive inspections of AC plant shells, replacing degraded flight deck and vehicle lashing socket components, overhauling main propulsion diesel engine components, preserving various tank and void spaces, repairing corroded deck and bulkhead areas, and addressing equipment functionality issues in critical ship systems. Most tasks are designated for outside repair activities or regional maintenance centers, with specific instructions for base metal buildup, corrosion control, cleaning, gas-free certification, and adherence to naval maintenance standards. The document indicates a systematic approach to maintaining the vessel's operational readiness through comprehensive scheduled maintenance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| LSD47 6C1 Tanks.pdf | ||
| 6C1 job list WITH DETAIL SPECS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Business Sensitive
09/06/2023 07:51:37 AM
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9358302 DA01-5260 CIWS MT 2 J-BAR DAVIT; LOADTEST 08-55-0-WEA 4/8/2027 DURING PMS IT WAS DISCORVERED THAT THE 05
LEVEL AFT MK749 MISSLE CONTAINER HANDLING
REQUEST REPAIR ACTIVITY TO LOAD TEST
PORTABLE DAVIT AND SOCKET IN
38E9358303 DA01-ZAT6 WEIGHT TEST BOAT DAVIT 01-69-4-WEA 4/8/2027 *HSC 58311121 *PRIDSLAD MRN-
GCMAAUXILMA0037UNNAMAINTENANCE
WEIGHT TEST BOAT DAVIT IN ACCORDANCE
WITH MRC A5H7. REPORT CONDITIONS
38E9366201 DB01-5108 VEHICLE LASHING SOCKET IN WELL
DECK; REPLACE
4-35-0-Q 4/8/2027 DURING PMS CHECK (18M-1) INSPECT " TOP PLATE
FLUSH-TYPE CLOVERLEAF TIE-DOWN DECK FITTINGS
IN THE WELL DECK, 20 PADEYES WERE FOUND TO BE
DEGRADED. THEY PASS THE GO-NO GAUGE TEST.
BUT ARE A FEW MONTHS AWAY FROM FAILING.
REQUEST OUTSIDE REPAIR ACTIVITY TO
REPLACE THE UNSAT PADEYESS AND TO
PERFORM THE NECESSARY LOAD TEST.
XXXPEJF 2023 SEP05 RESCREEN TO 4J1 XXX
38E9313901 DB01-5390 FLIGHT DECK TIEDOWNS; REPLACE 01-92-0-WEA 3/24/2027 DURING THE SHIP'S INSPECTION, WHILE
CONDUCTING PMS CHECK FOR MIP SERIES 5882/010,
REQUEST DEPOT LEVEL ACTIVITIES TO
REMOVE THE DEFECTIVE CROSSBAR TYPE
38E9313901 DB01-ZA90 FLIGHT DECK TIEDOWNS; REPLACE 01-92-0-WEA 3/24/2027 *HSC 13900NK10A *PRIDFLIGHT DECK MRN-
GCMACORROSA0027RL4LMAINTENANCE STANDARD:
REMOVE AND REPLACE THE FLIGHT DECK
TIEDOWNS IAW LSD 41 CSWT 130-012.
38E9312326 EA02-ZA72 JP-5 SERVICE TANK 6-98-5-J; REPAIR
AND PRESERVE
6-98-5-J 3/2/2027 *HSC 12312N31001 *PRID6-98-5-J MRN-
GCMACORROSA0027RNAVMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR IAW
SURFMEPP CORROSION TRD 220-100-016.
38E9312326 EA02-ZA73 JP-5 SERVICE TANK 6-98-5-J;ASSESS 6-98-5-J 10/29/2026 *HSC 12312N31001 *PRID6-98-5-J MRN-
GCMACORROSA0017RNAVMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312326 EA02-ZA74 JP-5 SERVICE TANK 6-98-5-J; REPAIR
AND PRESERVE
6-98-5-J 10/29/2026 *HSC 12312N31001 *PRID6-98-5-J MRN-
GCMACORROSA0037RNAVMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9351406 EA05-4896 NO 3 A/C PLANT SHELL; INSPECTION
AND REPAIR
3-74-1-E 10/29/2026 PER NAVAL ADVISORY S/F REQUEST FOR REGIONAL
MAINTENANCE CENTER (RMC) OR OTHER QUALIFIED
REPAIR ACTIVITIES TO CONDUCT AN INTRUSIVE
INSPECTION AND REPAIR OF AC PLANT SHELL
PRESSURE BOUNDARY SURFACES REFRIGERANT AND
OIL DRAIN PIPING SHELL PENETRATIONS AND
INSULATION.
S/F REQUEST AN INTRUSIVE INSPECTION AND
REPAIR OF AC PLANT SHELL PRESSURE
BOUNDARY SURFACES, REFRIGERANT AND OIL
DRAIN PIPING SHELL PENETRATIONS AND
INSULATION. S/F WILL SUBMIT REPORT AND
ROUTE TO TYCOM AS DIRECTED.
XXXPEJV- SHIPS FORCE HAS TUBES ON HAND
WHICH WILL LIKELY BE REQUIRED AFTER THE
INSTRUSIVE INSPECTIONXXX
38E9351407 EA05-4898 NO 2 A/C PLANT SHELL; INSPECTION
AND REPAIR
3-29-0-E 10/29/2026 PER NAVAL ADVISORY S/F REQUEST FOR REGIONAL
MAINTENANCE CENTER (RMC) OR OTHER QUALIFIED
REPAIR ACTIVITIES TO CONDUCT AN INTRUSIVE
INSPECTION AND REPAIR OF AC PLANT SHELL
PRESSURE BOUNDARY SURFACES REFRIGERANT AND
OIL DRAIN PIPING SHELL PENETRATIONS AND
INSULATION.
S/F REQUEST FOR REGIONAL MAINTENANCE
CENTER (RMC) OR OTHER QUALIFIED REPAIR
ACTIVITIES TO CONDUCT AN INTRUSIVE
INSPECTION AND REPAIR OF AC PLANT SHELL
PRESSURE BOUNDARY SURFACES,
REFRIGERANT AND OIL DRAIN PIPING SHELL
PENETRATIONS AND INSULATION. S/F WILL
SUBMIT REPORT AND ROUTE TO TYCOM, AS
DIRECTED.
XXXPEJV- SHIPS FORCE HAS TUBES ON HAND
WHICH WILL LIKELY BE REQUIRED AFTER THE
Page 1 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9351408 EA05-4899 NO 1 A/C PLANT SHELL; INSPECTION
AND REPAIR
3-29-0-E 10/29/2026 PER NAVAL ADVISORY S/F REQUEST FOR REGIONAL
MAINTENANCE CENTER (RMC) OR OTHER QUALIFIED
REPAIR ACTIVITIES TO CONDUCT AN INTRUSIVE
INSPECTION AND REPAIR OF AC PLANT SHELL
PRESSURE BOUNDARY SURFACES, REFRIGERANT AND
OIL DRAIN PIPING SHELL PENETRATIONS AND
INSULATION.
S/F REQUEST FOR REGIONAL MAINTENANCE
CENTER (RMC) OR OTHER QUALIFIED REPAIR
ACTIVITIES TO CONDUCT AN INTRUSIVE
INSPECTION AND REPAIR OF AC PLANT SHELL
PRESSURE BOUNDARY SURFACES,
REFRIGERANT AND OIL DRAIN PIPING SHELL
PENETRATIONS AND INSULATION. S/F WILL
SUBMIT REPORT AND ROUTE TO TYCOM, AS
DIRECTED.
XXXPEJV- SHIPS FORCE HAS TUBES ON HAND
WHICH WILL LIKELY BE REQUIRED AFTER THE
38E9351602 EA05-4905 NR2 REEFER FOUNDATION; REPAIR AND
PRESERVE
3-29-0-E 3/2/2027 NR2 REEFER FOUNDATION SEVERELY DEGRADED
REQUIRING EXTENSIVE OVERHAUL AND
PRESERVATION.
S/F TO REQUEST OUTSIDE ACTIVITY TO
OVERHAUL FOUNDATION TO INCLUDE
PRIMING AND PAINTING.
38E9351409 EA05-4906 NR1 A/C FOUNDATION; REPAIR AND
PRESERVE
3-29-0-E 3/2/2027 NR1 A/C FOUNDATION SEVERELY DEGRADED
REQUIRING EXTENSIVE PRESERVATION AND
OVERHAUL.
S/F TO REQUEST OUTSIDE ACTIVITY TO
OVERHAUL A/C FOUNDATION TO INCLUDE
PRIMING AND PAINTING.
38E9351601 EA05-4907 NR1 REEFER FOUNDATION; REPAIR AND
PRESERVE
3-29-0-E 3/2/2027 NR1 REEFER FOUNDATION SEVERELY DEGRADED
REQUIRING EXTENSIVE OVERHAUL AND
PRESERVATION.
S/F TO RECOMMEND OUTSIDE ACTIVITY TO
OVERHAUL NR1 REEFER FOUNDATION TO
INCLUDE PRIMING AND PAINTING.
XXXPECOMMENT - SRA.XXX
38E9351412 EA05-4908 NR4 A/C FOUNDATION; REPAIR AND
PRESERVE
3-74-1-E 3/2/2027 NR4 A/C FOUNDATION SEVERELY DEGRADED
REQUIRING OVERHAUL AND EXTENSIVE
PRESERVATION.
S/F TO REQUEST OUTSIDE ACTIVITY TO
OVERHAUL NR4 A/C FOUNDATION TO
INCLUDE PRIMING AND PAINTING
38E9351410 EA05-4909 NR2 A/C FOUNDATION; REPAIR AND
PRESERVE
3-29-0-E 3/2/2027 NR2 A/C FOUNDATION SEVERELY DEGRADED
REQUIRING EXTENSIVE OVERHAUL AND
PRESERVATION.
S/F TO REQUEST OUTSIDE ACTIVITY TO
OVERHAUL AND PRESERVATION INCLUDING
PRIMING AND PAINTING.
38E9351411 EA05-4910 NR3 A/C FOUNDATION; REPAIR AND
PRESERVE
3-74-1-E 3/2/2027 NR3 A/C FOUNDATION IS SEVERELY DEGRADED
REQUIRING EXTENSIVE OVERHAUL AND
PRESERVATION.
S/F TO REQUEST OUTSIDE ACTIVITY TO
OVERHAUL A/C FOUNDATION TO INCLUDE
PRIMING AND PAINTING.
JRMC Page 2 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9367201 EA05-5062 BRACKETS FOR LADDER IN A/C
MACHINERY ROOM; FABRICATE AND
INSTALL
3-59-2-E 3/2/2027 DURING MOB-E M-1, S/F DISCOVERED THAT THE
LADDER WELL TO AFT A/C ROOM BASE WAS
DEGRADED. THE PORT SIDE STRUCTURAL SUPPORTS
ON THE DECK, WHERE THE LADDER SAFETY PINS
WOULD ATTACH, WAS MISSING AND THE STARBOARD
SIDE WAS SEVERELY CORRODED. S/F WAS UNABLE TO
SECURE THE LADDER AT THE BASE, IN ITS CURRENT
CONDITION. THE COMPARTMENT IS ABOVE A FUEL
TANK AND S/F IN UNABLE TO WELD TO THE DECK.
S/F REQUEST OUTSIDE ACTIVITY TO EMPTY,
CLEAN, AND INSPECT FUEL OVERFLOW TANK 6-
74-3-F. ONCE COMPLETE S/F REQUEST
OUTSIDE ACTIVITY TO FABRICATE AND INSTALL
BRACKETS ON THE DECK TO SECURE LADDER.
XXXPEJV - TANK TO BE GAS FREED IN ORDER
TO PERFORM WELDING TO BRACKETS ON
TANK TOP. S/F LEADERSHIP PUSHES BACK ON
THIS BEING S/F CAPABLE DUE TO SAFETY
CONCERNS WITH WELDING ON A TANK TOP.
DEPOT-LEVEL REQUESTED. XXX
38E9366101 EB14-2115 DECK COVERING IN 2-99-2-Q; REPLACE 2-99-2-Q 3/2/2027 PRC DECKING IN COMPARTMENT 2-99-2-Q IS 13 FEET
BY 12 FEET.COMPARTMENT 2-99-2-Q PRC DECKING
SERVERLY DEGRADED. HOLE IN PRC DECKING IN
S/F CONTRACTS OUTSIDE ACTIVITY TO
REPLACE PRC DECKING IN COMPARTMENT 2-
99-2-Q.38E9312343 EB14-ZGZ9 G1N5 ASSESSMENT FOR LO-TK 6-65-2-W 6-65-2-W 10/29/2026 *HSC 12317N41022 *PRID6-65-2-W MRN-
GCMACORROSA0017QP0CMAINTENANCE STANDARD:
G1N5 LAST COMPLETED
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
REPORT TO LOCAL NSA AND INPUT SURVEY 38E9312345 EB14-ZH00 G1N5 ASSESSMENT FOR LO-TK 6-81-2-F 6-81-2-F 10/29/2026 *HSC 12317N41028 *PRID6-81-2-F MRN-
GCMACORROSA0017RNDFMAINTENANCE STANDARD:
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312341 EB14-ZH01 G1N5 ASSESSMENT FOR LO-TK 6-59-1-F 6-59-1-F 10/29/2026 *HSC 12317N41018 *PRID6-59-1-F MRN-
GCMACORROSA0017RNDBMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312342 EB14-ZH02 G1N5 ASSESSMENT FOR LO-TK 6-59-2-F 6-59-2-F 10/29/2026 *HSC 12317N41019 *PRID6-59-2-F MRN-
GCMACORROSA0017QNZWMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312344 EB14-ZH03 G1N5 ASSESSMENT FOR LO-TK 6-81-1-F 6-81-1-F 10/29/2026 *HSC 12317N41027 *PRID6-81-1-F MRN-
GCMACORROSA0017QNZXMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312346 EB14-ZH04 G1N5 ASSESSMENT FOR
CONTAMINATED OIL TANK 6-86-3-W
6-86-3-W 10/29/2026 *HSC 12317N41030 *PRID6-86-3-W MRN-
GCMACORROSA0017RNDJMAINTENANCE STANDARD:
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312347 EB14-ZH05 G1N5 ASSESSMENT FOR
CONTAMINATED OIL TANK 6-93-2-W
6-93-2-W 10/29/2026 *HSC 12317N41037 *PRID6-93-2-W MRN-
GCMACORROSA0017QNXVMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312341 EB14-ZH27 CONTAMINATED OIL TANK 6-59-1-F;
REPAIR
6-59-1-F 3/2/2027 *HSC 12317N41018 *PRID6-59-1-F MRN-
GCMACORROSA0027RNDBMAINTENANCE
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312341 EB14-ZH28 CONTAMINATED OIL TANK 6-59-1-F;
REPAIR
6-59-1-F 10/29/2026 *HSC 12317N41018 *PRID6-59-1-F MRN-
GCMACORROSA0037RNDBMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312342 EB14-ZH29 CONTAMINATED OIL TANK 6-59-2-F;
REPAIR
6-59-2-F 3/2/2027 *HSC 12317N41019 *PRID6-59-2-F MRN-
GCMACORROSA0027QNZWMAINTENANCE
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312342 EB14-ZH30 CONTAMINATED OIL TANK 6-59-2-F;
REPAIR
6-59-2-F 10/29/2026 *HSC 12317N41019 *PRID6-59-2-F MRN-
GCMACORROSA0037QNZWMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312343 EB14-ZH33 CONTAMINATED OIL TANK 6-65-2-
W;REPAIR
6-65-2-W 3/2/2027 *HSC 12317N41022 *PRID6-65-2-W MRN-
GCMACORROSA0027QP0CMAINTENANCE STANDARD:
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312343 EB14-ZH34 CONTAMINATED OIL TANK 6-65-2-
W;REPAIR
6-65-2-W 10/29/2026 *HSC 12317N41022 *PRID6-65-2-W MRN-
GCMACORROSA0037QP0CMAINTENANCE STANDARD:
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312344 EB14-ZH35 CONTAMINATED OIL TANK 6-81-1-F;
REPAIR
6-81-1-F 3/2/2027 *HSC 12317N41027 *PRID6-81-1-F MRN-
GCMACORROSA0027QNZXMAINTENANCE
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
JRMC Page 3 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312344 EB14-ZH36 CONTAMINATED OIL TANK 6-81-1-F;
REPAIR
6-81-1-F 10/29/2026 *HSC 12317N41027 *PRID6-81-1-F MRN-
GCMACORROSA0037QNZXMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312345 EB14-ZH37 CONTAMINATED OIL TANK 6-81-2-F;
REPAIR
6-81-2-F 3/2/2027 *HSC 12317N41028 *PRID6-81-2-F MRN-
GCMACORROSA0027RNDFMAINTENANCE STANDARD:
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312345 EB14-ZH38 CONTAMINATED OIL TANK 6-81-2-F;
REPAIR
6-81-2-F 10/29/2026 *HSC 12317N41028 *PRID6-81-2-F MRN-
GCMACORROSA0037RNDFMAINTENANCE STANDARD:
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312346 EB14-ZH39 CONTAMINATED OIL TANK 6-86-3-W;
REPAIR
6-86-3-W 3/2/2027 *HSC 12317N41030 *PRID6-86-3-W MRN-
GCMACORROSA0027RNDJMAINTENANCE STANDARD:
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312346 EB14-ZH40 CONTAMINATED OIL TANK 6-86-3-W;
REPAIR
6-86-3-W 10/29/2026 *HSC 12317N41030 *PRID6-86-3-W MRN-
GCMACORROSA0037RNDJMAINTENANCE STANDARD:
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9312347 EB14-ZH41 CONTAMINATED OIL TANK 6-93-2-W;
REPAIR
6-93-2-W 3/2/2027 *HSC 12317N41037 *PRID6-93-2-W MRN-
GCMACORROSA0027QNXVMAINTENANCE
CONDUCT ONLY BASE METAL BUILDUP REPAIR
IAW LSD 41 CSWT 123-063; CONTAMINATED
38E9312347 EB14-ZH42 CONTAMINATED OIL TANK 6-93-2-W;
REPAIR
6-93-2-W 10/29/2026 *HSC 12317N41037 *PRID6-93-2-W MRN-
GCMACORROSA0037QNXVMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW LSD 41 CSWT 123-068. CERTIFY AND
38E9365101 EE02-7666 40GAL STEAM KETTLE; REPLACE 03-37-0-Q 2/1/2027 DURING NORMAL OPERATION S/F DISCOVERED THAT
THE 40GAL STEAM INTERNALLY EXPLODED, DUE TO
S/F PROCURE MATERIAL AND PROVIDE TO
OUTSIDE ACTIVITY FOR INSTALLATION
38E9365101 EE02-7667 40GAL STEAM KETTLE; REPLACE 03-37-0-Q 2/1/2027 DURING NORMAL OPERATION S/F DISCOVERED THAT
THE 40GAL STEAM INTERNALLY EXPLODED, DUE TO
S/F REQUESTING OUTSIDE ACTIVITY TO
UNINSTALL, RIG OUT, AND DISPOSE OF OLD
38E9312315 EM01-6720 DECK PLATING ON MMR NO. ONE
UPPER LEVEL; REPAIR
5-52-0-E 3/2/2027 MMR1 UPPER LEVEL HAS CORROSION TO THE POINT
THAT HOLES ARE APPEARING IN THE DECK. WITH
REQUEST OUTSIDE ACTIVITY CONDUCT
CORROSION CONTROL ON THE UPPER LEVEL
38E9323327 EM01-U303 1B MPDE LEFT AND RIGHT BANK
EXHAUST MANIFOLD GASKETS; REPLACE
5-52-0-E 3/2/2027 ISEA REP TYLER BACKMAN (TBACKMAN@LCE.COM)
IDENTIFIED DURING MATERIAL ASSESSMENT REVIEW
REPLACE THE LEFT AND RIGHT BANK EXHAUST
HEADER GASKETS AND SOFTWARE FROM THE
38E9323301 EM01-ZE81 1B MPDE; REPAIR 5-52-0-E 3/2/2027 *HSC 233121 *PRID1B MPDE MRN-
GCMAPROPULA002A7567MAINTENANCE STANDARD:
REPAIR MPDE SHUTDOWN AIR CONTROL
VALVE ASSEMBLY (START/STOP RELAY VALVE,
38E9323301 EM01-ZE92 1B MPDE; REPAIR 5-52-0-E 3/2/2027 *HSC 233121 *PRID1B MPDE MRN-
GCMAPROPULA002A7567MAINTENANCE STANDARD:
OVERHAUL AND ALIGN THE FUEL CONTROL
CROSS SHAFT OF THE MAIN PROPULSION
38E9323309 EM01-ZE95 1A MPDE CRANKCASE VACUUM
SYSTEM: CLEAN
5-52-0-E 3/2/2027 *HSC 233111B1 *PRIDNO. 1A MRN-
GCMAPROPULA002A7557MAINTENANCE STANDARD:
CLEAN MAIN PROPULSION DIESEL ENGINE
CRANKCASE VACUUM FAN, SEPARATOR AND
38E9323316 EM01-ZE96 1B MPDE CRANKCASE VACUUM
SYSTEM: CLEAN
5-52-0-E 3/2/2027 *HSC 233121B1 *PRIDNO. 1B MRN-
GCMAPROPULA0027M0KBMAINTENANCE
CLEAN MAIN PROPULSION DIESEL ENGINE
CRANKCASE VACUUM FAN, SEPARATOR AND
38E9323310 EM01-ZE97 1B MPDE ENG INJE THERMOSTATIC
CONTROL VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 233121474 *PRID1B MPDE MRN-
GCMAPROPULA002A7594MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323311 EM01-ZE98 1A MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 233111474 *PRID1A MPDE MRN-
GCMAPROPULA002A7593MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323312 EM01-ZE99 1B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23312154 *PRID1B MPDE FO CLR MRN-
GCMAPROPULA002A7538MAINTENANCE STANDARD:
S9233-DM-HBK-010 LAST COMPLETED
02/01/2021 (Q-23310-A7R)MPDE
COOLERS REQUIRE CLEANING AND REPAIR.
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
INJECTION WATER COOLER OF THE MAIN
PROPULSION DIESEL ENGINE IN ACCORDANCE
NAVSEA MAINTENANCE STANDARD MS S9233-
DM-HBK-010. REPAIRS SHALL INCLUDE
MACHINING OF MATTING SURFACES.
CONDUCT OPERATIONL TEST AT 100 PERCENT
LOAD AS DESIGNATED BY THE SUPERVISOR.
JRMC Page 4 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9323317 EM01-ZEA0 1A MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23311155 *PRID1A MPDE LO CLR MRN-
GCMAPROPULA002A7533MAINTENANCE STANDARD:
S9233-DM-HBK-010 LAST COMPLETED
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
INJECTION WATER COOLER OF THE MAIN 38E9323318 EM01-ZEA1 1A MPDE AIR INTERCOOLER; REPAIR 5-52-0-E 3/2/2027 *HSC 233111E1 *PRIDMPDE 1A CLR1 MRN-
GCMAPROPULA0027TWNGMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323318 EM01-ZEA2 1A MPDE AIR INTERCOOLER; REPAIR 5-52-0-E 3/2/2027 *HSC 233111E2 *PRIDMPDE 1A CLR2 MRN-
GCMAPROPULA0027TWKLMAINTENANCE STANDARD:
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323313 EM01-ZEA3 1B MPDE AIR INTERCOOLER; REPAIR 5-52-0-E 3/2/2027 *HSC 233121E1 *PRIDMPDE 1B CLR1 MRN-
GCMAPROPULA0027TWKNMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323313 EM01-ZEA4 1B MPDE AIR INTERCOOLER; REPAIR 5-52-0-E 3/2/2027 *HSC 233121E2 *PRIDMPDE 1B CLR2 MRN-
GCMAPROPULA0027TWKQMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323319 EM01-ZEA5 1A MPDE SW TEMPERATURE
REGULATING VALVE; OVERHAUL
5-52-0-E 3/2/2027 *HSC 23311166 *PRID1A MPDE MRN-
GCMAPROPULA002A7589MAINTENANCE STANDARD:
MS2331-PC-003 LAST COMPLETED
02/01/2021 (Q-23310-A48)MAIN
PROPULSION DIESEL ENGINE 3-WAY SEAWATER
TEMPERATURE REGULATING VALVE REQUIRES
OVERHAUL.
OVERHAUL MAIN PROPULSION DIESEL ENGINE
3-WAY SEAWATER TEMPERATURE
REGULATING VALVE, TO INCLUDE THE
ACTUATOR ASSEMBLY, VOLUME BOOSTER
AND PILOT CONTROLS, IN ACCORDANCE WITH
TECH MAN. S9233-A8-MMO-A10.
38E9323320 EM01-ZEA6 1B MPDE SW TEMPERATURE
REGULATING VALVE; OVERHAUL
5-52-0-E 3/2/2027 *HSC 23312166 *PRID1B MPDE MRN-
GCMAPROPULA0027M0HWMAINTENANCE
STANDARD: MS2331-PC-003 LAST
COMPLETED 02/01/2021 (Q-23310-
A48)MAIN PROPULSION DIESEL ENGINE 3-WAY
SEAWATER TEMPERATURE REGULATING VALVE
REQUIRES OVERHAUL.
OVERHAUL MAIN PROPULSION DIESEL ENGINE
3-WAY SEAWATER TEMPERATURE
REGULATING VALVE, TO INCLUDE THE
ACTUATOR ASSEMBLY, VOLUME BOOSTER
AND PILOT CONTROLS, IN ACCORDANCE WITH
TECH MAN. S9233-A8-MMO-A10.
38E9312318 EM01-ZEB9 WASTE STORAGE TANK 6-61-2-W;
ASSESS
6-61-2-W 3/2/2027 *HSC 12319N91002 *PRID6-61-2-W MRN-
GCMACORROSA0017RNDCMAINTENANCE
STANDARD: G1N5 LAST COMPLETED
09/01/2014 (I-12319-A0C)CONDUCT
VOID/TANK AS ARRIVED SURVEY IN ACCORDANCE
WITH MRC G1N5.
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
REPORT TO LOCAL NSA AND INPUT SURVEY
DATA PER CORROSION CONTROL ASSESSMENT
AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
PROVIDE "AS-FOUND MATERIAL CONDITION"
CODE IN THE SECOND POSITION OF THE
"FINAL ACTION TAKEN" FIELD (2-KILO, BLOCK
64) IAW NAVSEAINST 4790.8 SERIES.
JRMC Page 5 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312318 EM01-ZEC1 WASTE STORAGE TANK 6-61-2-W;
ASSESS
6-61-2-W 10/29/2026 *HSC 12319N91002 *PRID6-61-2-W MRN-
GCMACORROSA0037RNDCMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 10/16/2010 (Q-12319-
A09)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312318 EM01-ZEC2 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
6-61-2-W 3/2/2027 *HSC 12319N91002 *PRID6-61-2-W MRN-
GCMACORROSA0027RNDCMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9323310 EM01-ZEC3 1B MPDE ENG INJE THERMOSTATIC
CONTROL VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 23312166 *PRID1B MPDE MRN-
GCMAPROPULA0027M0HWMAINTENANCE
STANDARD: S9233-DM-HBK-010 LAST
COMPLETED 02/01/2021 (Q-23310-
A87)THERMOSTATIC CONTROL VALVES REQUIRE
OVERHAUL.
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
THERMOSTATIC CONTROL VALVES IN
ACCORDANCE WITH NAVSEA MAINTENANCE
STANDARD MS S9233-DM-HBK-010 AND CSWT
233-023. INSTALL NEW ALUMINIZED SPRAY
CLOTH. CONDUCT OPERATIONAL TEST AT 100
PERCENT LOAD AS AS DESEIGNATED BY THE
38E9323311 EM01-ZEC4 1A MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 23311166 *PRID1A MPDE MRN-
GCMAPROPULA002A7589MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323311 EM01-ZEC5 1A MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 26211211W1 *PRID1A MPDE MRN-
GCMAPROPULA002B3763MAINTENANCE STANDARD:
S9233-DM-HBK-010 LAST COMPLETED
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
THERMOSTATIC CONTROL VALVES IN 38E9323310 EM01-ZEC6 1B MPDE ENG INJE THERMOSTATIC
CONTROL VALVES; OVERHAUL
5-52-0-E 3/2/2027 *HSC 26211221W1 *PRID1B MPDE MRN-
GCMAPROPULA0027PRSPMAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323328 EM01-ZEC8 1A MPDE FUEL OIL INJECTION PUMP:
OVERHAUL
5-52-0-E 3/2/2027 *HSC 233111 *PRID1A MPDE MRN-
GCMAPROPULA002B3253MAINTENANCE STANDARD:
OVERHAUL THE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES OF THE MAIN
38E9323329 EM01-ZEC9 1B MPDE FUEL OIL INJECTION PUMP:
OVERHAUL
5-52-0-E 3/2/2027 *HSC 233121 *PRID1B MPDE MRN-
GCMAPROPULA002A7567MAINTENANCE STANDARD:
S9233-DM-HBK-010 LAST COMPLETED
09/01/2020 (Q-23310-A7Z)FUEL
INJECTION PUMPS AND PUMP DRIVE REQUIRES
OVERHAUL
OVERHAUL THE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES OF THE MAIN
PROPULSION DIESEL ENGINE IN ACCORDANCE
WITH NAVSEA MAINTENANCE STANDARD MS
S9233-DM-HBK-010 AND CSWT 233-024,
CONDUCT OPERATIONAL TEST AND MAKE
FINAL TIMING ADJUSTMENTS AT 80 PERCENT
AND 100 PERCENT LOAD AS DESIGNATED BY
THE SUPERVISOR
38E9323312 EM01-ZED3 1B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23312162 *PRID1B MPDE JW CLR MRN-
GCMAPROPULA002A7536MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323312 EM01-ZED4 1B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23312155 *PRID1B MPDE LO CLR MRN-
GCMAPROPULA0027P1RMMAINTENANCE
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323317 EM01-ZED5 1A MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23311154 *PRID1A MPDE FO CLR MRN-
GCMAPROPULA002A7537MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
JRMC Page 6 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9323317 EM01-ZED6 1A MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-52-0-E 3/2/2027 *HSC 23311162 *PRID1A MPDE JW CLR MRN-
GCMAPROPULA002A7535MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323304 EM02-7533 2A MPDE SW TEMP REG VLV DEGRAD 5-74-0-E 3/2/2027 UPON NORMAL OPERATION S/F DISCOVERED 2A
MPDE SW/JW TEMP REGULATING VALVE WAS
REQUESTING OUTSIDE ACTIVITY OVERHAUL 2A
MPDE SW/JW TEMP REGULATING VALVE.
38E9323337 EM02-U300 2A MPDE ENGINE ROCKER ARM ASSY;
REPAIR
5-74-0-E 3/2/2027 ISEA REP TYLER BACKMAN (TBACKMAN@LCE.COM)
IDENTIFIED DURING MATERIAL ASSESSMENT REVIEW
THE FOLLOWING MAINTENANCE IS REQUIRED: 2A
REPAIR, ALIGN, AND ADJUST MAIN
PROPULSION DIESEL ENGINE ROCKER ARM
ASSEMBLIES IN ACCORDANCE WITH NAVSEA
38E9323330 EM02-U301 2A MPDE LEFT AND RIGHT BANK
EXHAUST MANIFOLD GASKETS; REPLACE
5-74-0-E 3/2/2027 ISEA REP TYLER BACKMAN (TBACKMAN@LCE.COM)
IDENTIFIED DURING MATERIAL ASSESSMENT REVIEW
REPLACE THE LEFT AND RIGHT BANK EXHAUST
HEADER GASKETS AND SOFTWARE FROM THE
38E9323339 EM02-U302 2B MPDE ENGINE ROCKER ARM ASSY;
REPAIR
5-74-0-E 3/2/2027 ISEA REP TYLER BACKMAN (TBACKMAN@LCE.COM)
IDENTIFIED DURING MATERIAL ASSESSMENT REVIEW
REPAIR, ALIGN, AND ADJUST MAIN
PROPULSION DIESEL ENGINE ROCKER ARM
38E9323304 EM02-ZDX0 2A MPDE SW TEMPERATURE
REGULATING VALVE; OVERHAUL
5-74-0-E 3/2/2027 *HSC 23313166 *PRID2A MPDE MRN-
GCMAPROPULA002A7590MAINTENANCE STANDARD:
OVERHAUL MAIN PROPULSION DIESEL ENGINE
3-WAY SEAWATER TEMPERATURE
38E9323314 EM02-ZDX6 2B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-74-0-E 3/2/2027 *HSC 23314155 *PRID2B MPDE LO CLR MRN-
GCMAPROPULA0027P1RLMAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323302 EM02-ZDX7 2A MPDE ; REPAIR 5-74-0-E 3/2/2027 *HSC 233131 *PRID2A MPDE MRN-
GCMAPROPULA002A7566MAINTENANCE STANDARD:
REPAIR MPDE SHUTDOWN AIR CONTROL
VALVE ASSEMBLY (START/STOP RELAY VALVE,
38E9323303 EM02-ZDX8 2B MPDE; REPAIR 5-74-0-E 3/2/2027 *HSC 233141 *PRID2B MPDE MRN-
GCMAPROPULA002A7565MAINTENANCE STANDARD:
REPAIR MPDE SHUTDOWN AIR CONTROL
VALVE ASSEMBLY (START/STOP RELAY VALVE,
38E9323305 EM02-ZDX9 2A MPDE LO PUMP; OVERHAUL 5-74-0-E 3/2/2027 *HSC 233131C1 *PRID2A MPDE MRN-
GCMAPROPULA0027SH2EMAINTENANCE STANDARD:
OVERHAUL THE ATTACHED LUBE LUBE OIL
PUMP AND RELIEF VALVE ASSEMBLY OF THE
38E9323306 EM02-ZDY0 2B MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-74-0-E 3/2/2027 *HSC 23314166 *PRID2B MPDE MRN-
GCMAPROPULA0027M0RXMAINTENANCE
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323302 EM02-ZDY9 2A MPDE ; REPAIR 5-74-0-E 3/2/2027 *HSC 233131 *PRID2A MPDE MRN-
GCMAPROPULA002A7566MAINTENANCE STANDARD:
OVERHAUL AND ALIGN THE FUEL CONTROL
CROSS SHAFT OF THE MAIN PROPULSION
38E9323303 EM02-ZDZ0 2B MPDE; REPAIR 5-74-0-E 3/2/2027 *HSC 233141 *PRID2B MPDE MRN-
GCMAPROPULA002A7565MAINTENANCE STANDARD:
OVERHAUL AND ALIGN THE FUEL CONTROL
CROSS SHAFT OF THE MAIN PROPULSION
38E9323307 EM02-ZDZ1 2B MPDE CRANKCASE VACUUM
SYSTEM: CLEAN
5-74-0-E 3/2/2027 *HSC 233141B1 *PRIDNO. 2B MRN-
GCMAPROPULA0027M0TBMAINTENANCE
CLEAN MAIN PROPULSION DIESEL ENGINE
CRANKCASE VACUUM FAN, SEPARATOR AND
38E9323306 EM02-ZDZ3 2B MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-74-0-E 3/2/2027 *HSC 233141474 *PRID2B MPDE MRN-
GCMAPROPULA002A7596MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323315 EM02-ZDZ5 2A MPDE FUEL INJECTOR COOLER;
REPAIR
5-74-0-E 3/2/2027 *HSC 23313154 *PRID2A MPDE FO CLR MRN-
GCMAPROPULA002A7539MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323308 EM02-ZDZ6 2B MPDE AIR INTERCOOLER; REPAIR 5-74-0-E 3/2/2027 *HSC 233141E2 *PRIDMPDE 2B CLR2 MRN-
GCMAPROPULA0027TWKUMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323308 EM02-ZDZ8 2B MPDE AIR INTERCOOLER; REPAIR 5-74-0-E 3/2/2027 *HSC 233141E1 *PRIDMPDE 2B CLR1 MRN-
GCMAPROPULA0027TWKWMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323325 EM02-ZE00 2B MPDE SW TEMPERATURE
REGULATING VALVE; OVERHAUL
5-74-0-E 3/2/2027 *HSC 23314166 *PRID2B MPDE MRN-
GCMAPROPULA0027M0RXMAINTENANCE
OVERHAUL MAIN PROPULSION DIESEL ENGINE
3-WAY SEAWATER TEMPERATURE
38E9323306 EM02-ZE09 2B MPDE THERMOSTATIC CONTROL
VALVES; OVERHAUL
5-74-0-E 3/2/2027 *HSC 26212221W1 *PRID2B MPDE MRN-
GCMAPROPULA0027PQ7PMAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323331 EM02-ZE12 2A MPDE AIR START DISTRIBUTOR AND
MAIN AIR START CONTROL VALVE;
5-74-0-E 3/2/2027 *HSC 233131 *PRID2A MPDE MRN-
GCMAPROPULA002A7566MAINTENANCE STANDARD:
OVERHAUL THE AIR START DISTRIBUTOR AND
MAIN AIR START CONTROL VALVE OF THE
JRMC Page 7 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9323332 EM02-ZE13 2B MPDE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES;
5-74-0-E 3/2/2027 *HSC 233141 *PRID2B MPDE MRN-
GCMAPROPULA002A7565MAINTENANCE STANDARD:
OVERHAUL THE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES OF THE MAIN
38E9323333 EM02-ZE14 2A MPDE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES;
5-74-0-E 3/2/2027 *HSC 233131 *PRID2A MPDE MRN-
GCMAPROPULA002A7566MAINTENANCE STANDARD:
OVERHAUL THE FUEL OIL INJECTION PUMP
AND INJECTION PUMP DRIVES OF THE MAIN
38E9323315 EM02-ZE17 2A MPDE FUEL INJECTOR COOLER;
REPAIR
5-74-0-E 3/2/2027 *HSC 23313155 *PRID2A MPDE LO CLR MRN-
GCMAPROPULA002A7534MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323314 EM02-ZE18 2B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-74-0-E 3/2/2027 *HSC 23314162 *PRID2B MPDE JW CLR MRN-
GCMAPROPULA0027M0SBMAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323314 EM02-ZE19 2B MPDE FUEL INJECTOR FL COOLER;
OVERHAUL
5-74-0-E 3/2/2027 *HSC 23314154 *PRID2B MPDE FO CLR MRN-
GCMAPROPULA002A7540MAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9323315 EM02-ZE20 2A MPDE FUEL INJECTOR COOLER;
REPAIR
5-74-0-E 3/2/2027 *HSC 23313162 *PRID2A MPDE JW CLR MRN-
GCMAPROPULA0027NPKLMAINTENANCE STANDARD:
CLEAN, REPAIR AND HYDROSTATICALLY TEST
EACH LUBE OIL, JACKET WATER, AND
38E9366204 EM03-3934 AUX MACHINERY ROOM INTAKE
VENTILATION; REPAIR
5-43-0-E 3/2/2027 IT WAS NOTED THAT THE VENTILATION INTAKES
LEADING TO AUX ONE THAT GOES THROUGH
REQUEST OUTSIDE ACTIVITY CONDUCT
CORROSION REPAIRS TO INTAKE VENTILATION.
38E9331102 EM03-ZBF3 NO.1 SSDG LO AND JW/SW CLG PUMPS,
OVERHAUL
5-43-0-E 3/2/2027 *HSC 31121114 *PRIDNO. 1 JW PMP MRN-
GCMAPROPULA0027M2HDMAINTENANCE
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE SHIP
38E9331102 EM03-ZBF5 NO.1 SSDG LO AND JW/SW CLG PUMPS,
OVERHAUL
5-43-0-E 3/2/2027 *HSC 31121116 *PRIDNO. 1 SW PMP MRN-
GCMAPROPULA002B5841MAINTENANCE STANDARD:
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE SHIP
38E9331105 EM03-ZBG2 NO.1 SSDG COOLING SYSTEM
COMPONENTS; REPAIR
5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
CLEAN AND REPAIR THE SHIP SERVICE DIESEL
GENERATOR COOLING SYSTEM COMPONENTS
38E9331101 EM03-ZBG4 NO.1 SSDG; OVERHAUL 5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL THE AIR START CHECK VALVESAND
REPLACE CYLINDER LINER ADAPTERS OF THE
38E9331104 EM03-ZBH5 NO.2 SSDG START AIR SYSTEM
COMPONENTS; OVERHAUL
5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE START AIR SYSTEM
COMPONENTS (AIR START DISTRIBUTOR, AIR
38E9331101 EM03-ZBI3 NO.1 SSDG GVRNR; CALIBRATE 5-43-0-E 3/2/2027 *HSC 311211181 *PRIDNO. 1 MRN-
GCMAPROPULA0027SNNHMAINTENANCE
REMOVE AND DELIVER TO AUTHORIZED OEM
FACILITY THE ELECTROHYDRAULIC GOVERNOR
38E9331101 EM03-ZBI4 NO.1 SSDG; OVERHAUL 5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL THE UPPER AND LOWER
TORSIONAL DAMPENERS OF THE SHIP SERVICE
38E9331102 EM03-ZBI8 NO.1 SSDG LO AND JW/SW CLG PUMPS,
OVERHAUL
5-43-0-E 3/2/2027 *HSC 31121111 *PRIDNO. 1 MRN-
GCMAPROPULA0027MY9QMAINTENANCE
OVERHAUL THE ATTACHED LUBE OIL PUMP OF
THE SHIP SERVICE DIESEL GENERATOR IN
38E9331101 EM03-ZBJ0 NO.1 SSDG; OVERHAUL 5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL THE FLEX DRIVE AND GOVERNOR
DRIVE ASSEMBLIES OF THE SHIP SERVICE
38E9355102 EM04-7517 PLATFORM UNDER NR 3 LPAC; REPAIR 5-89-01-E 3/2/2027 DURING DAILY WALKTHROUGH, S/F DISCOVERED
UPPER LEVEL PLATFORM IN AMR 2 (5-89-01-E) UNDER
S/F REQUEST OUTSIDE ACTIVITY TO CONDUCT
REPAIRS IAW STRUCTUREAL REQUIREMENTS
38E9365405 EM04-7529 VENT DUCTING FOR SUPPLY FAN 1-87-
1:REPLACE
2-87-3-L 3/2/2027 0 0
38E9365405 EM04-7535 VENT DUCTING FOR SUPPLY FAN 1-87-
1:REPLACE
2-87-3-L 3/2/2027 0 0
38E9312350 ER01-5976 FWD WASTE AND SOIL DRAINS; CLEAN 5-33-1-Q 2/1/2027 S/F DISCOVERED THAT THE FWD WASTE / SOIL DRAIN
PIPING LEADING TO MAIN CHT TANK 5-31-2-W HAS
S/F REQUESTS OUTSIDE ACTIVITY TO ACID
CLEAN ALL WASTE/ SOIL DRAINS 06 AND
38E9312309 ER01-ZJK8 CHT TANK 5-31-2-W; ASSESS 5-31-2-W 10/29/2026 *HSC 12319N91005 *PRID5-31-2-W MRN-
GCMACORROSA0017RN6PMAINTENANCE STANDARD:
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312303 ER01-ZJK9 REV-01(IH)~ SEWAGE EJECTION TANK IN
3-108-1-W; ASSESS
3-108-1-W 10/29/2026 *HSC 12319N91003 *PRID3-108-1-W MRN-
GCMACORROSA0017RN4SMAINTENANCE STANDARD:
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
JRMC Page 8 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312320 ER01-ZJL0 ACCESSIBLE VOID 1-28-1-V; ASESS 1-28-1-V 10/29/2026 *HSC 12322N11001 *PRID1-28-1-V MRN-
GCMACORROSA0017QP4GMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312303 ER01-ZJL1 SEWAGE EJECTION TANK 3-108-1-W;
REPAIR
3-108-1-W 10/29/2026 *HSC 12319N91003 *PRID3-108-1-W MRN-
GCMACORROSA0037RN4SMAINTENANCE STANDARD:
TRD 220-100-013 LAST COMPLETED
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE 38E9312327 ER01-ZJL2 WASTE STORAGE 6-83-1-W; REPAIR
AND PRESERVE
6-83-1-W 10/29/2026 *HSC 12319N91038 *PRID6-83-1-W MRN-
GCMACORROSA0037RNDGMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312339 ER01-ZJL3 G1N5 ASSESSMENT FOR ACCESSIBLE
VOID 6-48-1-V
6-48-1-V 10/29/2026 *HSC 12322N1101 *PRID6-48-1-V MRN-
GCMACORROSA0017TSMTMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 PER CORROSION CONTROL
38E9312305 ER01-ZJL5 REV-01(IH)~VOID (6-56-3-V); ASSESS 6-56-3-V 10/29/2026 *HSC 12322N1103 *PRID6-56-3-V MRN-
GCMACORROSA0017TSMVMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 PER CORROSION CONTROL
38E9312340 ER01-ZJL7 G1N5 ASSESSMENT FOR ACCESSIBLE
VOID 6-52-3-Q
6-52-3-Q 10/29/2026 *HSC 12322N11053 *PRID6-52-3-Q MRN-
GCMACORROSA0017RNDQMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 PER CORROSION CONTROL
38E9312338 ER01-ZJL8 G1N5 ASSESSMENT FOR ACCESSIBLE
VOID 5-41-0-Q
5-41-0-Q 10/29/2026 *HSC 12322N11027 *PRID5-41-0-Q MRN-
GCMACORROSA0017RN6RMAINTENANCE STANDARD:
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 PER CORROSION CONTROL
38E9312337 ER01-ZJL9 G1N5 ASSESSMENT FOR ACCESSIBLE
VOID 2-30-2-V
2-30-2-V 10/29/2026 *HSC 12322N11002 *PRID2-30-2-V MRN-
GCMACORROSA0017RNDMMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 PER CORROSION CONTROL
38E9312327 ER01-ZJM0 WASTE STORAGE TANK 6-83-1-W;
ASSESS
6-83-1-W 10/29/2026 *HSC 12319N91038 *PRID6-83-1-W MRN-
GCMACORROSA0017RNDGMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5. PROVIDE CONDITION FOUND
38E9312307 ER01-ZJM1 BALLAST TANK 5-129-0-W; REPAIR AND
PRESERVE
5-129-0-W 10/29/2026 *HSC 12316N11030 *PRID5-129-0-W MRN-
GCMACORROSA0037QNVXMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312334 ER01-ZJM2 BALLAST TANK 6-85-1-W; REPAIR AND
PRESERVE
6-85-1-W 10/29/2026 *HSC 12316N11096 *PRID6-85-1-W MRN-
GCMACORROSA0037QNXPMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312308 ER01-ZJM3 BALLAST TANK 5-121-1-W; REPAIR AND
PRESERVE
5-121-1-W 10/29/2026 *HSC 12316N11025 *PRID5-121-1-W MRN-
GCMACORROSA0037QNVSMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312310 ER01-ZJM4 BALLAST TANK 6-56-1-W; REPAIR AND
PRESERVE
6-56-1-W 10/29/2026 *HSC 12316N11071 *PRID6-56-1-W MRN-
GCMACORROSA0037QNWYMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 02/01/2021 (Q-12316-
A05)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312328 ER01-ZJM5 BALLAST TANK 6-81-3-W; REPAIR AND
PRESERVE
6-81-3-W 10/29/2026 *HSC 12316N11093 *PRID6-81-3-W MRN-
GCMACORROSA0037QNXKMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312332 ER01-ZJM6 BALLAST TANK 6-35-0-W; REPAIR AND
PRESERVE
6-35-0-W 10/29/2026 *HSC 12316N11059 *PRID6-35-0-W MRN-
GCMACORROSA0037QNWQMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312311 ER01-ZJM7 BALLAST TANK 6-29-0-W; REPAIR AND
PRESERVE
6-29-0-W 10/29/2026 *HSC 12316N11058 *PRID6-29-0-W MRN-
GCMACORROSA0037QNWPMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
JRMC Page 9 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312331 ER01-ZJM8 BALLAST TANK 6-83-0-W; REPAIR AND
PRESERVE
6-83-0-W 10/29/2026 *HSC 12316N11095 *PRID6-83-0-W MRN-
GCMACORROSA0037QNXNMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 02/01/2021 (Q-12316-
A05)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312302 ER01-ZJM9 SALT WATER BALLAST TANK; REPAIR
AND PRESERVE
5-115-1-W 10/29/2026 *HSC 12316N11022 *PRID5-115-1-W MRN-
GCMACORROSA0037QNVPMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 02/01/2021 (Q-12316-
A05)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312329 ER01-ZJN0 BALLAST TANK 6-89-1-W; REPAIR AND
PRESERVE
6-89-1-W 10/29/2026 *HSC 12316N11100 *PRID6-89-1-W MRN-
GCMACORROSA0037QP0GMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 02/01/2021 (Q-12316-
A05)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312330 ER01-ZJN1 BALLAST TANK 6-74-0-W; REPAIR AND
PRESERVE
6-74-0-W 10/29/2026 *HSC 12316N11087 *PRID6-74-0-W MRN-
GCMACORROSA0037QNXEMAINTENANCE
STANDARD: TRD 220-100-013 LAST
COMPLETED 02/01/2021 (Q-12316-
A05)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312333 ER01-ZJN2 BALLAST TANK 6-101-1-W; REPAIR AND
PRESERVE
6-101-1-W 10/29/2026 *HSC 12316N11043 *PRID6-101-1-W MRN-
GCMACORROSA0037QNXXMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
JRMC Page 10 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312307 ER01-ZJN3 BALLAST TANK 5-29-0-W; ASSESS 5-129-0-W 10/29/2026 *HSC 12316N11030 *PRID5-129-0-W MRN-
GCMACORROSA0017QNVXMAINTENANCE
STANDARD: G1N5 LAST COMPLETED
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL 38E9312334 ER01-ZJN4 BALLAST TANK 6-85-1-W; ASSES 6-85-1-W 10/29/2026 *HSC 12316N11096 *PRID6-85-1-W MRN-
GCMACORROSA0017QNXPMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312308 ER01-ZJN5 BALLAST TANK 5-121-1-W; ASSESS 5-121-1-W 10/29/2026 *HSC 12316N11025 *PRID5-121-1-W MRN-
GCMACORROSA0017QNVSMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312310 ER01-ZJN6 BALLAST TANK 6-56-1-W; ASSESS 6-56-1-W 10/29/2026 *HSC 12316N11071 *PRID6-56-1-W MRN-
GCMACORROSA0017QNWYMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312328 ER01-ZJN7 BALLAST TANK 6-81-3-W; ASSESS 6-81-3-W 10/29/2026 *HSC 12316N11093 *PRID6-81-3-W MRN-
GCMACORROSA0017QNXKMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312332 ER01-ZJN8 BALLAST TANK 6-35-0-W; ASSESS 6-35-0-W 10/29/2026 *HSC 12316N11059 *PRID6-35-0-W MRN-
GCMACORROSA0017QNWQMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312311 ER01-ZJN9 BALLAST TANK 6-29-0-W; ASSESS 6-29-0-W 10/29/2026 *HSC 12316N11058 *PRID6-29-0-W MRN-
GCMACORROSA0017QNWPMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312331 ER01-ZJO0 BALLAST TANK 6-83-0-W;ASSESS 6-83-0-W 10/29/2026 *HSC 12316N11095 *PRID6-83-0-W MRN-
GCMACORROSA0017QNXNMAINTENANCE
STANDARD: G1N5 LAST COMPLETED
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL 38E9312302 ER01-ZJO1 REV-01(IH)~SALTWATER BALLAST TANK
(5-115-1-W); ASSESS
5-115-1-W 10/29/2026 *HSC 12316N11022 *PRID5-115-1-W MRN-
GCMACORROSA0017QNVPMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312329 ER01-ZJO2 BALLAST TANK 6-89-1-W; ASSESS 6-89-1-W 10/29/2026 *HSC 12316N11100 *PRID6-89-1-W MRN-
GCMACORROSA0017QP0GMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312330 ER01-ZJO3 BALLAST TANK 6-74-0-W;ASSESS 6-74-0-W 10/29/2026 *HSC 12316N11087 *PRID6-74-0-W MRN-
GCMACORROSA0017QNXEMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312333 ER01-ZJO4 BALLAST TANK 6-101-1-W; ASSESS 6-101-1-W 10/29/2026 *HSC 12316N11043 *PRID6-101-1-W MRN-
GCMACORROSA0017QNXXMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY IAW
MRC G1N5 AND PER CORROSION CONTROL
38E9312320 ER01-ZJO5 ACCESSIBLE VOID 1-28-1-V; REPAIR 1-28-1-V 10/29/2026 *HSC 12322N11001 *PRID1-28-1-V MRN-
GCMACORROSA0037QP4GMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312330 ER01-ZJO6 BALLAST TANK 6-74-0-W; REPAIR AND
PRESERVE
6-74-0-W 3/2/2027 *HSC 12316N11087 *PRID6-74-0-W MRN-
GCMACORROSA0027QNXEMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 08/01/2021 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312308 ER01-ZJO7 BALLAST TANK 5-121-1-W; REPAIR AND
PRESERVE
5-121-1-W 4/8/2027 *HSC 12316N11025 *PRID5-121-1-W MRN-
GCMACORROSA0027QNVSMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 02/01/2021 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312310 ER01-ZJO8 BALLAST TANK 6-56-1-W; REPAIR AND
PRESERVE
6-56-1-W 4/8/2027 *HSC 12316N11071 *PRID6-56-1-W MRN-
GCMACORROSA0027QNWYMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312332 ER01-ZJO9 BALLAST TANK 6-35-0-W; REPAIR AND
PRESERVE
6-35-0-W 4/8/2027 *HSC 12316N11059 *PRID6-35-0-W MRN-
GCMACORROSA0027QNWQMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312311 ER01-ZJP0 BALLAST TANK 6-29-0-W; REPAIR AND
PRESERVE
6-29-0-W 4/8/2027 *HSC 12316N11058 *PRID6-29-0-W MRN-
GCMACORROSA0027QNWPMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
JRMC Page 11 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312331 ER01-ZJP1 BALLAST TANK 6-83-0-W; REPAIR AND
PRESERVE
6-83-0-W 4/8/2027 *HSC 12316N11095 *PRID6-83-0-W MRN-
GCMACORROSA0027QNXNMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312302 ER01-ZJP2 SALT WATER BALLAST TANK; REPAIR
AND PRESERVE
5-115-1-W 4/8/2027 *HSC 12316N11022 *PRID5-115-1-W MRN-
GCMACORROSA0027QNVPMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 02/01/2021 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312329 ER01-ZJP3 BALLAST TANK 6-89-1-W; REPAIR AND
PRESERVE
6-89-1-W 4/8/2027 *HSC 12316N11100 *PRID6-89-1-W MRN-
GCMACORROSA0027QP0GMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 08/01/2021 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312305 ER01-ZJP5 VOID (6-56-3-V); REPAIR AND PRESERVE 6-56-3-V 10/29/2026 *HSC 12322N1103 *PRID6-56-3-V MRN-
GCMACORROSA0037TSMVMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
38E9312333 ER01-ZJP8 BALLAST TANK 6-101-1-W; REPAIR AND
PRESERVE
6-101-1-W 4/8/2027 *HSC 12316N11043 *PRID6-101-1-W MRN-
GCMACORROSA0027QNXXMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312307 ER01-ZJP9 BALLAST TANK 5-129-0-W; REPAIR AND
PRESERVE
5-129-0-W 4/8/2027 *HSC 12316N11030 *PRID5-129-0-W MRN-
GCMACORROSA0027QNVXMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312334 ER01-ZJQ0 BALLAST TANK 6-85-1-W; REPAIR AND
PRESERVE
6-85-1-W 4/8/2027 *HSC 12316N11096 *PRID6-85-1-W MRN-
GCMACORROSA0027QNXPMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 03/07/2016 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312328 ER01-ZJQ1 BALLAST TANK 6-81-3-W; REPAIR AND
PRESERVE
6-81-3-W 4/8/2027 *HSC 12316N11093 *PRID6-81-3-W MRN-
GCMACORROSA0027QNXKMAINTENANCE
STANDARD: LSD 41 CSWT 123-051 LAST
COMPLETED 03/07/2016 (Q-12316-
A0C)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-051; BALLAST TANK; REPAIR.
38E9312309 ER01-ZJQ2 CHT TANK 5-31-2-W; REPAIR AND
PRESERVE
5-31-2-W 10/29/2026 *HSC 12319N91005 *PRID5-31-2-W MRN-
GCMACORROSA0037RN6PMAINTENANCE STANDARD:
TRD 220-100-013 LAST COMPLETED
12/11/2011 (Q-12319-
A07)VOID/TANK IS REQUIRED TO BE OPEN, CLEAN,
AND GAS FREE PER CORROSION CONTROL
ASSESSMENT AND MAINTENANCE MANUAL (CCAMM)
T9630-AB-MMD-010 REQUIREMENTS.
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-013.
CERTIFY AND MAINTAIN ATMOSPHERE SAFE
FOR WORKERS THROUGHOUT THE
AVAILABILITY. ALL SURFMEPP TECHNICAL
REFERENCE DOCUMENTS (TRDS) CAN BE
FOUND ON THE SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
OC).
38E9312303 ER01-ZJQ3 SEWAGE EJECTION TANK 3-108-1-W;
REPAIR
3-108-1-W 2/1/2027 *HSC 12319N91003 *PRID3-108-1-W MRN-
GCMACORROSA0027RN4SMAINTENANCE STANDARD:
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312309 ER01-ZJQ4 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
5-31-2-W 2/1/2027 *HSC 12319N91005 *PRID5-31-2-W MRN-
GCMACORROSA0027RN6PMAINTENANCE STANDARD:
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
JRMC Page 12 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312327 ER01-ZJQ5 WASTE STORAGE 6-83-1-W; REPAIR
AND PRESERVE
6-83-1-W 2/1/2027 *HSC 12319N91038 *PRID6-83-1-W MRN-
GCMACORROSA0027RNDGMAINTENANCE
STANDARD: LSD 41 CSWT 123-052 LAST
COMPLETED 03/07/2016 (Q-12319-
A0N)TANK/VOID REQUIRES STRUCTURAL REPAIR.
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
CSWT 123-052: WASTE WATER DRAIN TANK;
REPAIR.
38E9312305 ER01-ZJQ7 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
6-56-3-V 4/8/2027 *HSC 12322N1103 *PRID6-56-3-V MRN-
GCMACORROSA0027TSMVMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR IAW
SURFMEPP CORROSION TRD 220-100-016.
38E9312320 ER01-ZJQ8 ACCESSIBLE VOID 1-28-1-V; REPAIR 1-28-1-V 4/8/2027 *HSC 12322N11001 *PRID1-28-1-V MRN-
GCMACORROSA0027QP4GMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR ONLY
IN THE BOTTOM OF THE TANK IAW LSD 41
38E9312307 ER01-ZJT6 BALLAST TANK 5-129-0-W; REPAIR AND
PRESERVE
5-129-0-W 4/8/2027 *HSC 12316N11030 *PRID5-129-0-W MRN-
GCMACORROSA0027QNVXMAINTENANCE
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
38E9312334 ER01-ZJT7 BALLAST TANK 6-85-1-W; REPAIR AND
PRESERVE
6-85-1-W 4/8/2027 *HSC 12316N11096 *PRID6-85-1-W MRN-
GCMACORROSA0027QNXPMAINTENANCE
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
38E9312308 ER01-ZJT8 BALLAST TANK 5-121-1-W; REPAIR AND
PRESERVE
5-121-1-W 4/8/2027 *HSC 12316N11025 *PRID5-121-1-W MRN-
GCMACORROSA0027QNVSMAINTENANCE
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
38E9312310 ER01-ZJT9 BALLAST TANK 6-56-1-W; REPAIR AND
PRESERVE
6-56-1-W 4/8/2027 *HSC 12316N11071 *PRID6-56-1-W MRN-
GCMACORROSA0027QNWYMAINTENANCE
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
38E9312328 ER01-ZJU0 BALLAST TANK 6-81-3-W; REPAIR AND
PRESERVE
6-81-3-W 4/8/2027 *HSC 12316N11093 *PRID6-81-3-W MRN-
GCMACORROSA0027QNXKMAINTENANCE
STANDARD: TRD 220-100-015 LAST
COMPLETED 09/01/2015 (Q-12316-
A09)TANK/VOID REQUIRES TOUCH UP
PRESERVATION.
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
REGIONAL MAINTENANCE ACTIVITIES
(RMC/SRF/IMF) SHALL PROVIDE COPIES OF QA
DOCUMENTS TO THE LOCAL SURFMEPP
CORROSION REP FOR TANK CLOSEOUT AS
DIRECTED BY THE "OQE MINIMUM
REQUIREMENTS" SURFMEPP LTR AVAILABLE
AT
HTTPS://WWW.SPEAR.NAVY.MIL/SNAPSHOT
UNDER "REFERENCES/USER GUIDES". 009-32
OQE APPENDICES SHALL BE SUBMITTED TO
THE SURFMEPP CORROSION DIVISION (EMAIL:
SURFMEPP_CORROSION_STRUCTURES@NAVY
.MIL).ALL SURFMEPP TECHNICAL REFERENCE
DOCUMENTS (TRDS) CAN BE FOUND ON THE
SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
JRMC Page 13 of 17 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312302 ER01-ZJU1 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
5-115-1-W 4/8/2027 *HSC 12316N11022 *PRID5-115-1-W MRN-
GCMACORROSA0027QNVPMAINTENANCE
STANDARD: TRD 220-100-015 LAST
COMPLETED 09/01/2015 (Q-12316-
A09)TANK/VOID REQUIRES TOUCH UP
PRESERVATION.
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
REGIONAL MAINTENANCE ACTIVITIES
(RMC/SRF/IMF) SHALL PROVIDE COPIES OF QA
DOCUMENTS TO THE LOCAL SURFMEPP
CORROSION REP FOR TANK CLOSEOUT AS
DIRECTED BY THE "OQE MINIMUM
REQUIREMENTS" SURFMEPP LTR AVAILABLE
AT
HTTPS://WWW.SPEAR.NAVY.MIL/SNAPSHOT
UNDER "REFERENCES/USER GUIDES". 009-32
OQE APPENDICES SHALL BE SUBMITTED TO
THE SURFMEPP CORROSION DIVISION (EMAIL:
SURFMEPP_CORROSION_STRUCTURES@NAVY
.MIL).ALL SURFMEPP TECHNICAL REFERENCE
DOCUMENTS (TRDS) CAN BE FOUND ON THE
SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
38E9312329 ER01-ZJU2 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
6-89-1-W 4/8/2027 *HSC 12316N11100 *PRID6-89-1-W MRN-
GCMACORROSA0027QP0GMAINTENANCE
STANDARD: TRD 220-100-015 LAST
COMPLETED 09/01/2015 (Q-12316-
A09)TANK/VOID REQUIRES TOUCH UP
PRESERVATION.
PERFORM TOUCH UP PRESERVATION IAW
SURFMEPP CORROSION TRD 220-100-015.
REGIONAL MAINTENANCE ACTIVITIES
(RMC/SRF/IMF) SHALL PROVIDE COPIES OF QA
DOCUMENTS TO THE LOCAL SURFMEPP
CORROSION REP FOR TANK CLOSEOUT AS
DIRECTED BY THE "OQE MINIMUM
REQUIREMENTS" SURFMEPP LTR AVAILABLE
AT
HTTPS://WWW.SPEAR.NAVY.MIL/SNAPSHOT
UNDER "REFERENCES/USER GUIDES". 009-32
OQE APPENDICES SHALL BE SUBMITTED TO
THE SURFMEPP CORROSION DIVISION (EMAIL:
SURFMEPP_CORROSION_STRUCTURES@NAVY
.MIL).ALL SURFMEPP TECHNICAL REFERENCE
DOCUMENTS (TRDS) CAN BE FOUND ON THE
SURFMEPP SHAREPOINT SITE
(HTTPS://FLANKSPEED.SHAREPOINT-
MIL.US/SITES/NAVSEA_SURFMEPP_HQ/TECHD
38E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .