6C1 job list WITH DETAIL SPECS.pdf
PDF 146 KB Posted
- Attached to
- USS RUSHMORE 6C1 SRA Sources Sought
- Solicitation number
- 6C1
About this file
This document is a Business Sensitive maintenance task list for a naval vessel, detailing 84 specific repair, preservation, and maintenance activities scheduled between February 2027 and May 2027. The tasks cover a wide range of ship systems and locations, including ventilation systems, deck coverings, hydraulic systems, electrical components, engine parts, bilge areas, structural elements, and various mechanical equipment across multiple ship compartments and levels.
Key maintenance activities include replacing nonskid deck coverings, overhauling ship service diesel generators, cleaning reheater ducts, preserving bilge areas, repairing hull structures, replacing water control valves, and conducting industrial support services for well deck assessments. Most tasks are designated for outside repair activities or depot-level maintenance, with planned completion dates primarily clustered around March and April 2027. The document indicates comprehensive preventive and corrective maintenance efforts aimed at preserving the vessel's operational readiness and structural integrity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| LSD47 6C1 Tanks.pdf | ||
| RUS 6C1 WITHOUT SPECS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Business Sensitive
09/06/2023 07:51:37 AM
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312301 DA01-5243 VENT PIPING FOR FUEL OIL TANK;
REPLACE
01-57-2-WEA 3/2/2027 DURING INSPECTION OF RAS STATION 4/6 (01-52-2-
WEA), S/F DISCOVERED THAT A VENTILATION PIPE
REQUEST OUTSIDE REPAIR ACTIVITY TO
OVERHAUL THE VENTILATION PLENUM AT
38E9313902 DA01-ZAP5 NONSKID DECK COVERING ON FLIGHT
DECK; REPLACE
NOT-APPLIC 3/24/2027 *HSC 63400SY1332A*PRIDFLIGHT DECK MRN-
GCMACORROSA0027QMZWMAINTENANCE
PRESERVE THE FLIGHT DECK IAW LSD 41
CSWT 634-018. USING TYPE V COATINGS
38E9366202 DB01-5124 REPLACE SYNTHETIC BOARDS 4-35-0-Q 4/8/2027 DURING CONDITION 1A OPERATIONS, S/F LAUNCHED
THE LCU WHICH BACKED INTO THE WELL DECK
SYNTHETIC BOARDS KNOCKING OUT 5 OR 6 BOLTS
AND LOOSENING SEVERAL STUDS. THIS RESULTED IN
THE 6 SYNTHETIC BOARDS ON THE PORT SIDE NEAR
FRAME 121 LOOSE AND NOT FULLY SECURED TO THE
BULKHEAD. THE BOARDS PROTRUDE OUT,
RENDERING WELL DECK OPERATIONS UNSAFE.
REQUEST OUTSIDE REPAIR ACTIVITY SRF-
SASEBO JAPAN TO REPLACE BOLTS, AND
REATTACH THE LOSE SYNTHETIC BOARDS
NEAR FRAME 121 ON THE PORT SIDE IAW
5840 AP-1
XXXPEJV - APPROXIMATELY 3 BOARDS WILL
NEED TO BE REPLACED. THE SIDE BOARDS ARE
AT THE TOP OF THE WELL DECK, PORT SIDE.
XXX
38E9366203 DB01-5179 WOODEN BATTERBOARD IN WELL
DECK; REPAIR
4-35-0-Q 4/8/2027 DURING CONDITION 1A OPERATIONS WHILE
RECOVERING AN LCU, THE LCU HIT THE SIDE OF THE
REQUESTING OUTSIDE REPAIR ACTIVITY TO
REPLACE THE WOODEN BATTLE BOARD IAW
38E9366502 DB01-5188 JIB CRANE OVERHAUL 1-121-2-Q 4/8/2027 DURING INSPECTION OF OLD JOB TO OVERHAUL
MONORAIL SYSTEM SHIPS FORCE NOTICED THAT THE
REQUEST OUTSIDE REPAIR ACTIVITY TO
UNRIG JIB CRANE FOR CANVAS SHOP
38E9313701 DB01-5201 NONSKID DECK COVERING ON
FORECASTLE DECK; REPLACE
02 LVL DECK 4/8/2027 DURING QUARTERLY INSPECTION IAW NSTM 631,
634 AND 772 AND UTILIZING MIP 6342/001 MRC Q-1
REQUEST OUTSIDE REPAIR ACTIVITY TO
REMOVE AND REPLACE ENTIRE NONSKID AND
38E9313701 DB01-5329 NONSKID DECK COVERING ON
FORECASTLE DECK; REPLACE
02 LVL DECK 4/8/2027
38E9366202 DB01-5331 SYNTHETIC BATTERBOARD; REPAIR 4-35-0-Q 4/8/2027 DURING OPERATIONS IN THE WELL DECK AT FRAME
131 THERE IS A MISSING WELL DECK BATTER BOARD
RECOMMEND DEPOT LEVEL REPAIR TO
PROCURE MATERIAL FOR DECKING AND
38E9361201 DB01-ZAB0 DECK EDGE CRES SAFETY NET
ASSEMBLY ON HELICOPTER DECK; LOAD
SHIP-WIDE 3/24/2027 *HSC 612210000S *PRIDSAFETY NETS MRN-
GCMAAUXILMA0017TXLKMAINTENANCE STANDARD:
LOAD TEST CRES DECK EDGE SAFETY NETS
IAW MRC A5K5 EVERY 36M. LOAD TEST
38E9358401 EA04-ZBG6 STERN GATE HYDRAULIC SYSTEM;
OVERHAUL
4-135-0-Q 4/8/2027 *HSC 584210 *PRIDSTERN GATE MRN-
GCMAAUXILMA0027P1VAMAINTENANCE
OVERHAUL STERN GATE HYDRAULIC SYSTEM
IN ACCORDANCE WITH CSWT LSD 41 584-025.
38E9358402 EA04-ZBJ3 STERN GATE RUBBER GASKET; REPLACE 4-135-0-Q 4/8/2027 *HSC 584210 *PRIDSTERN GATE MRN-
GCMAAUXILMA0027P1VAMAINTENANCE
STANDARD: CSWT LSD 41 584-001 LAST
COMPLETED 03/29/2015 (Q-58420-
A02)STERN GATE TRANSOM GASKET REQUIRES
REPLACE STERN GATE TRANSOM GASKET IN
ACCORDANCE WITH CSWT LSD 41 584-001.
38E9358901 EA04-ZBL5 15 TON TRAVELLING BRIDGE CRANE P/S
HOIST WINCH WIRE ROPE ASSEMBLY;
1-35-0-Q 4/8/2027 *HSC 589211 *PRIDBRIDGE CRANE MRN-
GCMAAUXILMA003B4687MAINTENANCE STANDARD:
LOAD TEST CRANE IN ACCORDANCE WITH
NSTM CHAPTER 572. REPORT CONDITIONS
38E9351401 EA05-4891 FLEXIBLE HOSE ASSEMBLY ON NO.ONE
AND NO.2 A/C PLANT; FABRICATE
3-29-0-E 3/2/2027 DURING ROUTINE PMS S/F DISCOVERED EXPIRED
FLEXIBLE HOSE. S/F TO REQUEST OUTSIDE ACTIVITY
REQUEST OUTSIDE ACTIVITY TO
MANUFACTURE AND HYDROSTATICALLY TEST
38E9351401 EA05-L068 FLEXIBLE HOSE ASSEMBLY ON NO.ONE
AND NO.2 A/C PLANT; FABRICATE
3-29-0-E 3/2/2027 DURING ROUTINE PMS S/F DISCOVERED EXPIRED
FLEXIBLE HOSE S/F TO REQUEST OUTSIDE ACTIVITY
REQUEST OUTSIDE ACTIVITY TO
MANUFACTURE HOSE UPON COMPLETION
38E9351404 EA05-ZBA0 WATER CONTROL VALVE FOR NO.2 A/C
PLANT CONDENSER; REPLACE
3-29-0-E 3/2/2027 *HSC 514221R1 *PRIDNO.2 MRN-
GCMAAUXILFA0027RYCSMAINTENANCE STANDARD:
REPLACE CONDENSER WATER CONTROL
VALVE IN ACCORDANCE WITH CSWT LCC 514-
Page 1 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9351405 EA05-ZBA1 WATER CONTROL VALVE FOR NO.ONE
A/C PLANT CONDENSER; REPLACE
3-29-0-E 3/2/2027 *HSC 514211R1 *PRIDNO.1 MRN-
GCMAAUXILFA0027RYCHMAINTENANCE STANDARD:
REPLACE CONDENSER WATER CONTROL
VALVE IN ACCORDANCE WITH CSWT LCC 514-
38E9351402 EA05-ZBA3 WATER CONTROL VALVE FOR NO.4 A/C
PLANT CONDENSER; REPLACE
3-74-1-E 3/2/2027 *HSC 514241R1 *PRIDNO.4 MRN-
GCMAAUXILFA0027SVMLMAINTENANCE STANDARD:
REPLACE CONDENSER WATER CONTROL
VALVE IN ACCORDANCE WITH CSWT LCC 514-
38E9351403 EA05-ZBA4 WATER CONTROL VALVE FOR NO.3 A/C
PLANT CONDENSER; REPLACE
3-74-1-E 3/2/2027 *HSC 514231R1 *PRIDNO.3 MRN-
GCMAAUXILFA0027SVMKMAINTENANCE STANDARD:
TRD 230-514-051 LAST COMPLETED
06/01/2020 (Q-51420-
A2A)CONDENSER WATER CONTROL VALVE REQUIRES
REPLACEMENT.
REPLACE CONDENSER WATER CONTROL
VALVE IN ACCORDANCE WITH CSWT LCC 514-
003. REPORT CONDITIONS FOUND TO SHIP'S
CSMP.
38E9312314 EE02-L056 FAN ROOM (01-14-2-Q); REPAIR AND
PRESERVE
01-14-2-Q 4/8/2027 PER 21530EE02ZCP1XX /PLEASE REFER THE REPORT
38RSM11001 OF 01-14-2-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY HITOSHI IKEMOTO,
38E9312316 EM01-6780 BILGE AREA IN MAIN MACHINERY
ROOM NUMBER ONE; PRESERVE
5-52-0-E 3/2/2027 WHILE CONDUCTING INSPECTION OF SPACE. IT WAS
NOTED THAT THE BILGE HAS A 100' X 100' SECTION
REQUEST OUTSIDE ACTIVITY CONDUCT
CORROSION CONTROL MEASURES BY
38E9355101 EM01-L125 UPPER LEVEL DECK PLATE IN 5-52-0-E;
REPAIR
5-52-0-E 3/2/2027 0 0
38E9323326 EM01-U204 1B MPDE OVERSPEED COVERNOR ASSY;
REPAIR
5-52-0-E 3/2/2027 0 0
38E9323334 EM01-ZE82 1A MPDE SHUTDOWN AIR CNTRL VLV
ASSY ; REPAIR
5-52-0-E 3/2/2027 *HSC 233111 *PRID1A MPDE MRN-
GCMAPROPULA002B3253MAINTENANCE STANDARD:
REPAIR MPDE SHUTDOWN AIR CONTROL
VALVE ASSEMBLY (START/STOP RELAY VALVE,
38E9311001 EM01-ZE88 BILGE IN MAIN MACHINERY ROOM
NUMBER ONE; ASSESS
5-52-0-E 3/2/2027 *HSC 12341CC02211*PRIDBILGE MMR1 MRN-
GCMACORROSA0017U1TRMAINTENANCE
ACCOMPLISH SURVEY OF THE BILGE IN
ACCORDANCE WITH MRC G1N6. RECORD AND
38E9312317 EM01-ZEC0 BILGE AREA IN FWD SHAFT ALLEY;
PRESERVE
5-67-1-Q 3/2/2027 *HSC 12348CC18782*PRIDFWD SHFT ALY MRN-
GCMACORROSA0027TQEPMAINTENANCE
PRESERVE THE BILGE IAW LSD 41 CSWT 631-
045; PRESERVE THE BILGES.
38E9323335 EM02-U201 2A MPDE OVERSPEED GOVERNOR
ASSEMBLY; REPAIR
5-74-0-E 3/2/2027 ISEA REP DUANE PAULSEN
(DUANE.PAULSEN@NAVY.MIL) IDENTIFIED DURING
MATERIAL ASSESSMENT REVIEW THE FOLLOWING
_REPAIR AND SET THE OVERSPEED
MECHANISM OF THE MAIN PROPULSION
DIESEL ENGINE IN ACCORDANCE WITH
38E9323322 EM02-ZDZ2 2A MPDE CRANKCASE VACUUM
SYSTEM: CLEAN
5-74-0-E 3/2/2027 *HSC 233131B1 *PRIDNO. 2A MRN-
GCMAPROPULA0027UFWAMAINTENANCE
CLEAN MAIN PROPULSION DIESEL ENGINE
CRANKCASE VACUUM FAN, SEPARATOR AND
38E9323323 EM02-ZDZ4 2A MPDE L/O, J/W AND INJ CLG
THERMOSTATIC VLV; REPAIR
5-74-0-E 3/2/2027 *HSC 23313166 *PRID2A MPDE MRN-
GCMAPROPULA002A7590MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323324 EM02-ZDZ7 2A MPDE R/L BANK INTERCOOLER;
CLEAN, INSPECT AND REPAIR
5-74-0-E 3/2/2027 *HSC 233131E1 *PRIDMPDE 2A CLR1 MRN-
GCMAPROPULA0027TWKSMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9323324 EM02-ZDZ9 2A MPDE R/L BANK INTERCOOLER;
CLEAN, INSPECT AND REPAIR
5-74-0-E 3/2/2027 *HSC 233131E2 *PRIDMPDE 2A CLR2 MRN-
GCMAPROPULA0027QP6BMAINTENANCE
CLEAN AND REPAIR THE AIR INTERCOOLER
AND AIR DRYER ASSEMBLY OF THE MAIN
38E9312319 EM02-ZE07 BILGE AREA IN MAIN MACHINERY
ROOM NUMBER 2; PRESERVE
5-74-0-E 3/2/2027 *HSC 12341CC02221*PRIDBILGE MMR2 MRN-
GCMACORROSA0027U1TSMAINTENANCE
PRESERVE THE BILGE IAW LSD 41 CSWT 631-
045; PRESERVE THE BILGES.
38E9323323 EM02-ZE08 2A MPDE L/O, J/W AND INJ CLG
THERMOSTATIC VLV; REPAIR
5-74-0-E 3/2/2027 *HSC 233131474 *PRID2A MPDE MRN-
GCMAPROPULA002A7595MAINTENANCE STANDARD:
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9323323 EM02-ZE10 2A MPDE L/O, J/W AND INJ CLG
THERMOSTATIC VLV; REPAIR
5-74-0-E 3/2/2027 *HSC 26212211W1 *PRID2A MPDE MRN-
GCMAPROPULA0027PQ7NMAINTENANCE
OVERHAUL THE LUBE OIL, JACKET WATER,
AND INJECTION COOLING WATER
38E9331108 EM03-ZBF2 NO.2 SSDG ATT PUMP; REPAIR 5-43-0-E 3/2/2027 *HSC 31122111 *PRIDNO. 2 MRN-
GCMAPROPULA002B2817MAINTENANCE STANDARD:
OVERHAUL THE ATTACHED LUBE OIL PUMP
OF THE SHIP SERVICE DIESEL GENERATOR IN
JRMC Page 2 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9331108 EM03-ZBF4 OVHL SSDG SW/JW PUMPS 5-43-0-E 3/2/2027 *HSC 31122116 *PRIDNO. 2 SW PMP MRN-
GCMAPROPULA0027M2KHMAINTENANCE
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE
38E9331108 EM03-ZBF6 OVHL SSDG SW/JW PUMPS 5-43-0-E 3/2/2027 *HSC 31122114 *PRIDNO. 2 JW PMP MRN-
GCMAPROPULA002B2341MAINTENANCE STANDARD:
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE
38E9331109 EM03-ZBF7 NO.1 SSDG AOR START SYSTEM
COMPONENT; REPAIR
5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL THE START AIR SYSTEM
COMPONENTS (AIR START DISTRIBUTOR, AIR
38E9331110 EM03-ZBG3 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE AIR START CHECK VALVESAND
REPLACE CYLINDER LINER ADAPTERS OF THE
38E9331113 EM03-ZBG9 NO. ONE SSDG BLOWER AIR BYPASS
VALVE; REPAIR
5-43-0-E 3/2/2027 *HSC 31121117 *PRIDSSDG 1 MRN-
GCMAPROPULA002B2350MAINTENANCE STANDARD:
OVERHAUL THE BLOWER AIR BYPASS VALVE
ON THE SHIP SERVICE DIESEL GENERATOR IN
38E9331110 EM03-ZBH6 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE SHIP SERVICE DIESEL
GENERATOR IN ACCORANCE WITH NAVSEA
38E9331106 EM03-ZBH8 NO. ONE SSDG ENGINE COMPONENT;
REPAIR
5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL AND ADJUST THE FUEL OIL
INJECTION NOZZLES AND REPLACE NOZZLE
38E9331110 EM03-ZBH9 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL AND ADJUST THE FUEL OIL
INJECTION NOZZLES AND REPLACE NOZZLE
38E9331110 EM03-ZBI0 NO.2 SSDG FO INJ PUMP AND
GOVERNOR; REPAIR AND CALIBRATE
5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL AND CALIBRATE THE FUEL OIL
INJECTION PUMPS OF THE SHIP SERVICE
38E9331106 EM03-ZBI1 NO.ONE SSDG FO INJT PMP; REPAIR
AND CALIBRATE
5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL AND CALIBRATE THE FUEL OIL
INJECTION PUMPS OF THE SHIP SERVICE
38E9331110 EM03-ZBI2 NO.2 SSDG FO INJ PUMP AND
GOVERNOR; REPAIR AND CALIBRATE
5-43-0-E 3/2/2027 *HSC 311221181 *PRIDNO. 2 MRN-
GCMAPROPULA0027SNNMMAINTENANCE
REMOVE AND DELIVER TO AUTHORIZED OEM
FACILITY THE ELECTROHYDRAULIC GOVERNOR
38E9331110 EM03-ZBI5 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE UPPER AND LOWER
TORSIONAL DAMPENERS OF THE SHIP
38E9331106 EM03-ZBI6 NO. ONE SSDG ENGINE COMPONENT;
REPAIR
5-43-0-E 3/2/2027 *HSC 3112111 *PRIDSSDG #1 MRN-
GCMAPROPULA002A8623MAINTENANCE STANDARD:
OVERHAUL THE FUEL OIL CONTROL SYSTEM
COMPONENTS OF THE SHIP SERVICE DIESEL
38E9331110 EM03-ZBI7 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE FUEL OIL CONTROL SYSTEM
COMPONENTS OF THE SHIP SERVICE DIESEL
38E9331110 EM03-ZBI9 NO.2 SSDG ENG; REPAIR 5-43-0-E 3/2/2027 *HSC 3112211 *PRIDSSDG 2 MRN-
GCMAPROPULA002B2349MAINTENANCE STANDARD:
OVERHAUL THE FLEX DRIVE AND GOVERNOR
DRIVE ASSEMBLIES OF THE SHIP SERVICE
38E9331103 EM04-ZCB7 NO.4 SSDG CENTER SECTION
OVERHAUL; ACCOMPLISH
5-89-01-E 3/2/2027 *HSC 3112411 *PRIDSSDG 4 MRN-
GCMAPROPULA0027M2PJMAINTENANCE
OVERHAUL AND ADJUST THE FUEL OIL
INJECTION NOZZLES AND REPLACE NOZZLE
38E9331107 EM04-ZCB8 NO.4 SSDG ATT SW, JW, AND LO PUMP;
REPAIR
5-89-01-E 3/2/2027 *HSC 31124111 *PRIDNO. 4 MRN-
GCMAPROPULA002B5840MAINTENANCE STANDARD:
OVERHAUL THE ATTACHED LUBE OIL PUMP
OF THE SHIP SERVICE DIESEL GENERATOR IN
38E9331107 EM04-ZCC0 NO.4 SSDG ATT SW, JW, AND LO PUMP;
REPAIR
5-89-01-E 3/2/2027 *HSC 31124116 *PRIDNO.4 SW PMP MRN-
GCMAPROPULA0027M2QBMAINTENANCE
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE
38E9331107 EM04-ZCC2 NO.4 SSDG ATT SW, JW, AND LO PUMP;
REPAIR
5-89-01-E 3/2/2027 *HSC 31124114 *PRIDNO.4 JW PMP MRN-
GCMAPROPULA0027M2PWMAINTENANCE
OVERHAUL THE ATTACHED JACKET WATER
AND SEAWATER COOLING PUMPS OF THE
38E9331112 EM04-ZCC7 CLN/RPR SSDG COOLING SYSTEM 5-89-01-E 3/2/2027 *HSC 3112411 *PRIDSSDG 4 MRN-
GCMAPROPULA0027M2PJMAINTENANCE
CLEAN AND REPAIR THE SHIP SERVICE DIESEL
GENERATOR COOLING SYSTEM COMPONENTS
38E9331103 EM04-ZCE6 NO.4 SSDG CENTER SECTION
OVERHAUL; ACCOMPLISH
5-89-01-E 3/2/2027 *HSC 3112411 *PRIDSSDG 4 MRN-
GCMAPROPULA0027M2PJMAINTENANCE
OVERHAUL THE SHIP SERVICE DIESEL
GENERATOR IN ACCORANCE WITH NAVSEA
38E9331103 EM04-ZCE9 NO.4 SSDG CENTER SECTION
OVERHAUL; ACCOMPLISH
5-89-01-E 3/2/2027 *HSC 3112411 *PRIDSSDG 4 MRN-
GCMAPROPULA0027M2PJMAINTENANCE
OVERHAUL AND CALIBRATE THE FUEL OIL
INJECTION PUMPS OF THE SHIP SERVICE
JRMC Page 3 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9331103 EM04-ZCF2 NO.4 SSDG CENTER SECTION
OVERHAUL; ACCOMPLISH
5-89-01-E 3/2/2027 *HSC 311241181 *PRIDNO. 4 MRN-
GCMAPROPULA0027SNNVMAINTENANCE
REMOVE AND DELIVER TO AUTHORIZED OEM
FACILITY THE ELECTROHYDRAULIC GOVERNOR
38E9331103 EM04-ZCG1 NO.4 SSDG CENTER SECTION
OVERHAUL; ACCOMPLISH
5-89-01-E 3/2/2027 *HSC 3112411 *PRIDSSDG 4 MRN-
GCMAPROPULA0027M2PJMAINTENANCE
OVERHAUL THE FUEL OIL CONTROL SYSTEM
COMPONENTS OF THE SHIP SERVICE DIESEL
38E9312336 ER01-5992 DISCHARGE PIPING (VALVE 4-33-9);
REPLACE
5-33-1-Q 2/1/2027 S/F DISCOVERED DEGRADED PIPING IN THE
DISCHARGE PIPE LEADING OVERBOARD FROM VALVE
S/F REQUEST OUTSIDE ACTIVITY TO
FABRICATE AND REPLACE DEGRADED SECTION
38E9312304 ER01-ZJL4 REV-01(IH)~ACCESSIBLE VOID 6-48-2-V;
ASSESS
6-48-2-V 10/29/2026 *HSC 12322N1102 *PRID6-48-2-V MRN-
GCMACORROSA0017TSMUMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY
IAW MRC G1N5 PER CORROSION CONTROL
38E9312306 ER01-ZJL6 REV-01(IH)~ACCESSIBLE VOID 6-56-4-V;
ASSESS
6-56-4-V 10/29/2026 *HSC 12322N1104 *PRID6-56-4-V MRN-
GCMACORROSA0017TSMWMAINTENANCE
ACCOMPLISH PRE-MAINTENANCE SURVEY
IAW MRC G1N5 PER CORROSION CONTROL
38E9312304 ER01-ZJP4 ACCESSIBLE VOID 6-48-2-V; REPAIR 6-48-2-V 10/29/2026 *HSC 12322N1102 *PRID6-48-2-V MRN-
GCMACORROSA0037TSMUMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-
38E9312306 ER01-ZJP6 ACCESSIBLE VOID 6-56-4-V; REPAIR 6-56-4-V 10/29/2026 *HSC 12322N1104 *PRID6-56-4-V MRN-
GCMACORROSA0037TSMWMAINTENANCE
OPEN, CLEAN, AND GAS FREE THE VOID/TANK
IAW SURFMEPP CORROSION TRD 220-100-
38E9312306 ER01-ZJP7 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
6-56-4-V 4/8/2027 *HSC 12322N1104 *PRID6-56-4-V MRN-
GCMACORROSA0027TSMWMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR IAW
SURFMEPP CORROSION TRD 220-100-016.
38E9312304 ER01-ZJQ6 REV-02(DV)~COFFERDAM; INSTALL AND
REMOVE
6-48-2-V 4/8/2027 *HSC 12322N1102 *PRID6-48-2-V MRN-
GCMACORROSA0027TSMUMAINTENANCE
CONDUCT BASE METAL BUILDUP REPAIR IAW
SURFMEPP CORROSION TRD 220-100-016.
38E9316804 ER09-5845 RAISED WATERTIGHT QUICK ACTING
SCUTTLE ASSEMBLY #03-63-1; REPLACE
03-63-1-L 4/8/2027 DURING SECAP INSPECTION SCUTTLE 03-63-1 WAS
DISCOVERED WITH HEAVY CORROSION ON THE
HINGE SIDE INSPECTORS RECOMMEND REPLACING
REQUESTING OUTSIDE ACTIVITY TO PROCURE
A NEW SCUTTLE, POWDER COAT NEW
SCUTTLE REMOVE OLD SCUTTLE INSTALL 38E9316801 ER09-5902 FLUSH WATERTIGHT QUICK ACTING
SCUTTLE ASSEMBLY #02-36-1; REPLACE
02-35-5-Q 4/8/2027 DURING PMS, IT WAS DISCOVERED THAT QAWTS 02-
36-1 HAS CORROSION ON THE FRAME AND BRACE
REQUESTING OUTSIDE ACTIVITY PROCURE
NEW QAWTS AND FRAME, POWDERCOAT
38E9312321 ES01-NP4F DECK IN FAN ROOM; PRESERVE 06-37-2-Q 4/8/2027 PER 21530NN01ZA08XX /PLEASE REFER THE REPORT
38RSM11001 OF 06-37-2-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY HITOSHI IKEMOTO,
38E9312322 ES01-NP4G FAN ROOM(1-85-1-Q); REPAIR AND
PRESERVE
1-85-1-Q 4/8/2027 PER 21530DB01ZAA4XX /PLEASE REFER THE REPORT
38RSM11001 OF 1-85-1-Q/PLEASE SEE IN SHARE
/REPAIR OR REPLACE KICKPIPE WITH NEW
ONE./ ASSESSED BY MASAKI TAGUCHI, POC Y
38E9312322 ES01-NP4H FAN ROOM(1-85-1-Q); REPAIR AND
PRESERVE
1-85-1-Q 4/8/2027 PER 21530DB01ZAA4XX /PLEASE REFER THE REPORT
38RSM11001 OF 1-85-1-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY MASAKI TAGUCHI,
38E9313902 ES01-NP4M NONSKID DECK COVERING ON FLIGHT
DECK; REPLACE
01-92-0-WEA 3/24/2027 PER 21530DB01ZA95XX /PLEASE REFER THE REPORT
38RSM11001 OF 01-92-0-WEA/PLEASE SEE IN SHARE
/REPLACE OR REPAIR WITH NEW DECK
COVERING./ ASSESSED BY YUUSUKE
38E9312323 ES01-NP4R STERN GATE OPERATION RM 3-138-2-
Q; PRESERVE
3-138-2-Q 4/8/2027 PER 21530EA04ZBK2XX /PLEASE REFER THE REPORT
38RSM11005 OF 3-138-2-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY GO MIYATA, POC Y
38E9312319 ES01-NP4T BILGE AREA IN MAIN MACHINERY
ROOM NUMBER 2; PRESERVE
5-74-0-E 3/2/2027 PER 21530EM02ZDY5XX /PLEASE REFER THE REPORT
38RSM11011 OF 5-74-0-E(BILGE)/PLEASE SEE IN
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY GO MIYATA, POC Y
38E9312324 ES01-NP4V DECK SURFACE IN 3-74-1-E; PRESERVE 3-74-1-E 3/2/2027 PER 21530EA05ZB98XX /PLEASE REFER THE REPORT
38RSM11001 OF 3-74-1-E/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY GO MIYATA, POC Y
38E9312314 ES01-NP4Z FAN ROOM (01-14-2-Q); REPAIR AND
PRESERVE
01-14-2-Q 4/8/2027 PER 21530EE02ZCP1XX /PLEASE REFER THE REPORT
38RSM11001 OF 01-14-2-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED./ ASSESSED BY HITOSHI IKEMOTO,
38E9313602 ES01-NP52 NONSKID DECK COVERING ON 1-14-0-
Q; REPLACE
1-14-0-Q 4/8/2027 PER 21530EE01ZB24XX /PLEASE REFER THE REPORT
38RSM11001 OF 1-14-0-Q/PLEASE SEE IN SHARE
/PRESERVATION IAW NSI 009-32 AND CCAMM
REQUIRED/ ASSESSED BY HITOSHI IKEMOTO,
38E9312325 ES01-NP55 PORT SIDE FLIGHT DECK SUPPORT
STRUCTURE; REPAIR
01-98-2-WEA 3/24/2027 DFS LSD-47-1009-2023 IS TIED TO THIS JCN. RATED AS
R3/S5 IAW SDRM IN SURFMEPP DM 220-042 REV C.
ACCOMPLISH REPAIR RECOMMENDATION IN
LEVEL TWO STRUCTURAL INSPECTION
JRMC Page 4 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9312325 ES01-NP56 PORT SIDE FLIGHT DECK SUPPORT
STRUCTURE; REPAIR
01-98-2-WEA 3/24/2027 DFS LSD-47-1009-2023 IS TIED TO THIS JCN. RATED AS
R3/S5 IAW SDRM IN SURFMEPP DM 220-042 REV C.
ACCOMPLISH REPAIR RECOMMENDATION IN
LEVEL TWO STRUCTURAL INSPECTION
38E9313601 ES01-NP73 REV-01(FO1)~DECK COAMING ON 06
LEVEL WEATHER DECK; REPAIR
06-21-01-WEA 4/8/2027 PER , R3/S5 FOR SDRM. 2" LG X 1/2" H HOLE IN DECK
COAMING AS A PART OF THE DECK HOUSE SIDE
CROP OUT AND REPLACE THE PLATE IN
ACCORDANCE WITH NSTM 100-2.8. ASSESSED
38E9313601 ES01-NP74 REV-01(FO1)~DECK COAMING ON 06
LEVEL WEATHER DECK; REPAIR
06-21-01-WEA 4/8/2027 PER , R3/S5 FOR SDRM. TWO HOLES, 6" LG X 3" H
AND 1/2" DIA, IN DECK COAMING AS A PART OF THE
CROP OUT AND REPLACE THE PLATE IN
ACCORDANCE WITH NSTM 100-2.8. ASSESSED
38E9312321 ES01-NP75 DECK IN FAN ROOM; PRESERVE 06-37-2-Q 4/8/2027 PER , R2/S5 FOR SDRM. DETERIORATED FLAT BAR OF
A PIPING SUPPORT ON 06 LEVEL DECK.
CROP OUT AND REPLACE THE FLAT BAR.
ASSESSED BY YOSHIZUMI IIDA, POC DAVID
38E9313602 ES01-NP76 NONSKID DECK COVERING ON 1-14-0-
Q; REPLACE
1-14-0-Q 4/8/2027 PER , R3/S5 FOR SDRM. HOLED WEB AND THINNING
FLANGE OF VERTICAL STIFFENER L6P ON THE
CROP OUT AND REPLACE THE STIFFENER IN
ACCORDANCE WITH NSTM 100-2.8. ASSESSED
38E9313602 ES01-NP77 NONSKID DECK COVERING ON 1-14-0-
Q; REPLACE
1-14-0-Q 4/8/2027 PER , R3/S5 FOR SDRM. HOLED WEB AND THINNING
FLANGE OF VERTICAL STIFFENER L5P ON THE
CROP OUT AND REPLACE THE STIFFENER IN
ACCORDANCE WITH NSTM 100-2.8. ASSESSED
38E9312322 ES01-NP78 FAN ROOM(1-85-1-Q); REPAIR AND
PRESERVE
1-85-1-Q 4/8/2027 PER , R3/S5 FOR SDRM. EDGE LOSS IN THE FLANGE
AND A HOLE IN THE WEB AT THE LOWER SECTION OF
CROP OUT AND REPLACE THE STIFFENER IN
ACCORDANCE WITH NSTM 100-2.8. ASSESSED
38E9312335 ES01-NP90 BALLAST TANK VENT PIPING; REPLACE 01-119-1-Q 4/8/2027 PER 21530DA01ZAS8, DETERIORATED PIPE WAS
FOUND AT STBD SIDE. DAMAGE SIZE WAS 2.
REPAIR OR REPLACE PIPE WITH NEW ONE.
ASSESSED BY MASAKI TAGUCHI, POC PAUL
38E9312349 ES01-NP9I DECK OF ESCAPE TRUNK; PRESERVE 5-66-4-T 3/2/2027 PER 21530EM01ZEB5, CCIMS PAINT CONDITION IS 4.
VISIBLE PART OF PAINT: 42.5 SQFT CORROSION
FOR DECK PAINT CONDITION, FULL
PRESERVATION REQUIRED. THE UT
JRMC Page 5 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9386401 EXSY-ZA48 WELL DECK IN 4-35-0-Q; ASSESS NOT-APPLIC 5/17/2027 *HSC 86411SV1443A*PRIDSVCE ROUTINE MRN-
GCMAKC000118217QPDQMAINTENANCE
STANDARD: NO "R" TASK TEMPLATE LAST
COMPLETED 09/01/2011 (R-86411-
A06)MRC G1N6 ASSESSMENT OF THE WELL DECK
REQUIRES INDUSTRIAL SUPPORT SERVICES.
PROVIDE INDUSTRIAL SERVICES IN SUPPORT
OF THE SURVEYOR(S) ACCOMPLISHING THE
MRC G1N6 ASSESSMENT PER CMP TASK I-
12342-A01. REQUIRED SERVICES INCLUDE:
(A) PROVIDE JLG AND OPERATOR TO
SUPPORT MRC G1N6 ASSESSMENT OF THE
WELL DECK OVERHEAD STRUCTURE. (B)
REMOVE BATTERBOARDS AND WELL DECK
PLANKING AS IDENTIFIED BY THE MRC G1N6
ASSESSMENT SURVEYOR. REINSTALL
REMOVED BATTERBOARDS AND WELL DECK
PLANKING AFTER COMPLETION OF THE
ASSESSMENT. (C) THE MRC G1N6
ASSESSMENT SURVEYOR SHALL NOTIFY THE
SHIP AND PORT ENGINEER 72 HOURS PRIOR
TO USE OF THE JLG AND OPERATOR. THE
SURVEYOR SHALL NOTIFY THE SHIP AND PORT
ENGINEER WHEN THE JLG AND OPERATOR
ARE NO LONGER REQUIRED. NOTE 1:
SCHEDULE THIS TASK FOR ACCOMPLISHMENT
CONCURRENT WITH CMP TASK I-12342-A01.
TASK NORMALLY ACCOMPLISHED DURING A
CMAV INSTEAD OF A CNO DEPOT
AVAILABILITY. NOTE 2: WORK SPECIFIED IN
PARAGRAPH (B) IS NOT REQUIRED WHEN
SHIPS FORCE REMOVES AND REINSTALLS THE
38E9386402 EXSY-ZA53 WAVEGUIDE AND TRANSMISSION LINE
DRY AIR LAY-UP; PROVIDE
NOT-APPLIC 5/17/2027 *HSC 86491SV1391A*PRIDSVCE ROUTINE MRN-
GCMAKC000118217QPHZMAINTENANCE STANDARD:
PROVIDE DRY AIR LAY-UP FOR ALL
PRESSURIZED WAVE GUIDES AND
38E9313601 OT01-0945 NONSKID DECK COVERING AND DECK
PLATE AT 06 LEVEL WEATHER DECK;
06-57-2-WEA 4/8/2027 DURING INSPECTION IT WAS NOTED THAT THE 06
LEVEL WEATHER DECK NONSKID IS IN NEED OF
REQUEST DEPOT LEVEL REPLACE ALL NON-
SKID ON 06 LEVEL WEATHER DECK NONSKID.
38E9367102 OW02-L011 NON-SKID DECK COVERING ON FWD 04
LEVEL WEATHER DECK; REPLACE
04-13-0-WEA 4/8/2027 FWD RAM WEATHER DECK FRAME 13-21 HAS
SIGNIFICANT CORROSION DAMAGE TO BOTH NON-
REQUEST OUTSIDE ACTIVITY REPAIR
CORROSION TO DECK AND RE-APPLY NON
38E9367103 OW02-L012 HULL STRUCTURE ON 04 LEVEL DECK;
REPAIR
04-13-0-WEA 4/8/2027 RAM EQPT RM 1 ON THE FWD RAM DECK HAS
SIGNIFICANT CORROSION TO THE METAL BELOW THE
REQUEST OUTSIDE ACTIVITY REPAIR AND
REPLACE THE CORRODED METAL UNDER THE
38E9365502 SERV-L128 ELM-225077; ACCOMPLISH 2-111-1-Q 4/8/2027 DURING THE PRC REPAIR IN COMPARTMENT 2-111-1-
Q CORROSION; HOLES, THINNING, ETC. WERE FOUND
REQUEST OUTSIDE ACTIVITY TO MAKE
REPAIRS TO ITEMS 5-7 AND 12-20 AS
38E9367101 SS02-4937 REHEATER AND DUCT IN 04-59-0-L;
CLEAN
04-59-0-L 4/8/2027
38E9364301 SS02-4938 REHEATER DUCT 03-31-1, 03-35-0-Q;
CLEAN
03-31-1-L 4/8/2027
38E9364101 SS02-4939 VENTILATION SYSTEM; CLEAN AND
INSPECT
06-25-3-L 4/8/2027 ACCESS TO REHEATER/DUCT INACCESSIBLE. SEE NOT
3 OF MRC A-14. MIP SERIES 5121
REQUESTING OUTSIDE ACTIVITY TO CLEAN
REHEATER/DUCT IN THE NEXT CNO/TYCOM
JRMC Page 6 of 7 Business Sensitive
ICN
JCN Summary Location PCD Problem Description Required Repair
38E9364102 SS02-4940 REHEATER DUCT 05 LVL; CLEAN 05-24-1-L 4/8/2027
38E9364102 SS02-4941 REHEATER DUCT 05 LVL; CLEAN 05-26-2-L 4/8/2027
38E9364101 SS02-4942 VENTILATION SYSTEM; CLEAN AND
INSPECT
06-34-2-L 4/8/2027 ACCESS TO REHEATER/DUCT INACCESSIBLE. SEE NOT
3 OF MRC A-14. MIP SERIES 5121
REQUESTING OUTSIDE ACTIVITY TO CLEAN
REHEATER/DUCT IN THE NEXT CNO/TYCOM
38E9364103 SS02-4944 REHEATER AND DUCT ON 05 LEVEL;
CLEAN
05-32-6-L 4/8/2027
38E9364103 SS02-4945 REHEATER AND DUCT ON 05 LEVEL;
CLEAN
05-32-1-L 4/8/2027
38e9364302 SS02-4946 REHEATER AND DUCT IN 05-56-2-L;
CLEAN
05-56-2-L 4/8/2027
38E9364102 SS02-4947 REHEATER DUCT 05 LVL; CLEAN 05-27-1-L 4/8/2027
38E9364301 SS02-4948 REHEATER DUCT 03-31-1, 03-35-0-Q;
CLEAN
03-35-0-Q 4/8/2027
38E9364103 SS02-4949 REHEATER AND DUCT ON 05 LEVEL;
CLEAN
05-35-8-L 4/8/2027
JRMC Page 7 of 7 Business Sensitive
List Report
File details come from the government source that posted it. Updated .