About this file

This document is a technical drawing for roof trusses to be used in the Governor's Housing program in Iowa. The drawing provides specifications for 24 roof trusses, including dimensions, materials, load requirements, and fabrication notes. The trusses are designed to meet IBC 2018 and TPI 2014 standards for 115 mph wind speeds, snow loads, and other factors.

The related state and local contract opportunity is for 35 sets of trusses for homes in the State of Iowa, specifically in Jones County. The contract does not provide additional details on the procurement process, such as response due dates, award timing, or contract term. The drawing indicates the trusses are being produced by the Alpine Job Designer program on behalf of the truss manufacturer.

View the file

Other files

File Type Posted
RFB913INSTR.dat —
FLOOR TRUSS.pdf PDF
RFB913PRICE.dat —

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TC LL REF

TC DL DATE

BC DL DRWG

BC LL

TOT.LD. O/A LEN.

DUR.FAC.

TYPE

**WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING!

**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.

Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.

Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise.

Refer to drawings 160A-Z for standard plate positions.

ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation & bracing of trusses.

A seal on this drawing or cover page listing this drawing, indicates acceptance of professionalA seal on this drawing or cover page listing this drawing, indicates acceptance of professionalA seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this drawingengineering responsibility solely for the design shown. The suitability and use of this drawingengineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.

For more information see this job’s general notes page and these web sites:

ITWBCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; ICC: www.iccsafe.org

TAG = T2

OH LEFT RAKE = 2'3"7 OH RIGHT RAKE = 2'3"7

LEFT JIG = 12'11"8 RIGHT JIG = 12'11"8

DESIGN CRIT=IBC2018/TPI-2014 FT/RT=20%(0%)/10(0)PLT. TYP.-WAVE

30.0psf 10.0psf 10.0psf 0.0psf 50.0psf 1.15

SPACING 24.0" SPEC

JOB #: Q21-1006

231100

KJK

03-05-2021

REV. 19.02.02C.1006.11QTY= 24 TOTAL= 24

SEQ = 81643

23'11"

6'4"12 5'6"12 5'6"12 6'4"12

7'10"15 8'1"3 7'10"15

11'11"8 11'11"8

2'2" 2'2"

1'

'1

"1

'0

"3

T1

T1

M1

M1

B1 B1

W1

W2

W2 W1

4X12(E5) 3X6

2X4

3X4

5X6

3X6 3X4

2X4

3X6 4X12(E5)

R=1384# U=43# RL=92/-92# W=5"8

(Rigid Surface)

R=1384# U=43# W=5"8 (Rigid Surface)

Top chord 2x4 SPF 2400f-2.0E Bot chord 2x4 SPF 1650f-1.5E Webs 2x4 SPF 1650f-1.5E Lt Slider: 2x6 SPF 1650f-1.5E; block length = 1.500' Rt Slider: 2x6 SPF 1650f-1.5E; block length = 1.500'

115 mph wind, 15.00 ft mean hgt, ASCE 7-16, CLOSED bldg, Located anywhere in roof, RISK CAT II, EXP C, wind TC DL=6.0 psf, wind BC DL=6.0 psf.

Wind loads and reactions based on MWFRS with additional C&C member design.

Wind loading based on both gable and hip roof types.

Deflection meets L/360 live and L/240 total load. Creep increase factor for dead load is 2.00.

Truss designed for unbalanced snow load based on Pg=35.00 psf, Ct=1.20, Ce=1.00, CAT II (Is=1.00) & Pf=29.40 psf.

Uplifts based on an elevation at or above 1000 ft.

Job:(Q21-1006) /GOVERNOR'S HOUSING ( IWOA / R2 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT

SCALE =0.2781

TC LL REF

TC DL DATE

BC DL DRWG

BC LL

TOT.LD. O/A LEN.

DUR.FAC.

TYPE

**WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING!

**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS.

Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.

Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise.

Refer to drawings 160A-Z for standard plate positions.

ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation & bracing of trusses.

A seal on this drawing or cover page listing this drawing, indicates acceptance of professionalA seal on this drawing or cover page listing this drawing, indicates acceptance of professionalA seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this drawingengineering responsibility solely for the design shown. The suitability and use of this drawingengineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.

For more information see this job’s general notes page and these web sites:

ITWBCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; ICC: www.iccsafe.org

TAG = T7

OH LEFT RAKE = 2'3"7 OH RIGHT RAKE = 2'3"7

LEFT JIG = 12'10"14 RIGHT JIG = 12'10"14

DESIGN CRIT=IBC2018/TPI-2014 FT/RT=20%(0%)/10(0)PLT. TYP.-WAVE

30.0psf 10.0psf 10.0psf 0.0psf 50.0psf 1.15

SPACING 24.0" GABL

JOB #: Q21-1006

231100

KJK

03-05-2021

REV. 19.02.02C.1006.11QTY= 2 TOTAL= 2

SEQ = 81654

23'11"

1'3"8

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'4"

1'3"8

11'11"8 11'11"8

2'2" 2'2"

10"7

'1

"4

'0

"3

T1

T1

B1 B1

W1 W1 M1

M2 M3

M4

M5

M6

M7

M8

M9

M8

M7

M6

M5

M4 M3

M2 M1

3X4(**)

4X5

5X6 3X4(**)

R=130plf U=100plf RL=8/-8plf W=11'11"8 (Rigid Surface)

R=119plf U=100plf W=11'11"8 (Rigid Surface)

Top chord 2x4 SPF 1650f-1.5E Bot chord 2x4 SPF 1650f-1.5E Webs 2x4 SPF 1650f-1.5E

All plates are 2X4 except as noted.

(**) 2 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements.

115 mph wind, 15.00 ft mean hgt, ASCE 7-16, CLOSED bldg, Located anywhere in roof, RISK CAT II, EXP C, wind TC DL=6.0 psf, wind BC DL=6.0 psf. Wind loads and reactions based on MWFRS with additional C&C member design.

Wind loading based on both gable and hip roof types.See DWGS A11515ENC160118, GBLLETIN0118, & GABRST160118 for gable wind bracing and other requirements.

Deflection meets L/360 live and L/240 total load. Creep increase factor for dead load is 2.00.Truss designed for unbalanced snow load based on Pg=35.00 psf, Ct=1.20, Ce=1.00, CAT II (Is=1.00) & Pf=29.40 psf.

Fasten rated sheathing to one face of this frame.Uplifts based on an elevation at or above 1000 ft.

Job:(Q21-1006) /GOVERNOR'S HOUSING ( IWOA / R1 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT

SCALE =0.2781