ROOF_SAFETY_RAILING-PKG_1-CD_Set.pdf

PDF 5 MB Posted

Attached to
Corrections Campus Wide Roof Safety Rails
Solicitation number
Y26-706
Issued by
Orange County, Orlando City, Florida

About this file

This is a construction document set for Roof Safety Railings prepared by Rhodes+Brito Architects for the Orange County Government Capital Projects Division, located at 3503 Vision Blvd in Orlando, Florida. The project involves providing fall protection safety devices at various locations on the roofs of Buildings D, E, and F at the Orange County Corrections Campus. The scope includes installing safety railings, single-point tie-offs, horizontal lifelines, selective roof demolition, and limited roofing work around new safety installations. The documents are dated March 14, 2023, and represent a 95% Construction Documents (CD) review submittal.

The project documents specify that no modifications will be made to existing roof top mechanical systems or utilities. The design team will install fall protection systems including 42-inch high guard railings, self-closing gates, and access ladders. Detailed structural and architectural drawings provide specifications for anchoring systems, including using Hilti anchoring products and ensuring minimal disruption to existing roof structures. The installation will require careful coordination with the facility to maintain operational continuity, with contractors required to protect existing items from damage and coordinate work hours and potential utility shutdowns with the owner. The project is designed to comply with the 2020 Florida Building Code and includes comprehensive inspection and special inspection requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

x x x x x

H

SF-6-1

BLDG. G-HORIZON

BLDG. H (GENESIS)

BLDG. A

BLDG. I (PHOENIX)

BLDG. K

BLDG. U (CEP 2)

BLDG. M

BLDG. S (BUTLER)

A-SUPPORT

BLDG. V-EMB

BLDG. N (KITCHEN/LAUNDRY)

BLDG. P

CHWR

RF-2

HWR

CHWR

HWR

RF-1

RD

RD

RD

RD

C H

W R

R T U

-1

H W

R

C H

W R

R T U

-1

H W

R

CHWR

RTU-16

HWR

CHWR

RTU-17

HWR

C H

W R

R T U

-1

H W

R

C H

W R

R T U

-1

H W

R

RTU-12

RTU-13

RF-8

EF-14

EF-13

EF-12

RF-7

EF-11

RF-6

RF-5

EF-10

AHU-9

AHU-10

AHU-11

AHU-8

EF-17

EF-16

EF-15

EF-11

EF-11

RF-4

EF-9

RF-3

EF-8

RD RD

RD

RD

RD

EF-11D

EF-13D

EF-16D

EF-14D

R D -1

2" V T R

R D

R D

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

V E N T C A P

E X -3

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

H B

H B

2" V T R

ASC0

E X -2

2" V T R

2" V T R

2" V T R E X -1

V -1

E X -7

ASC0

ASC0

C U -1A

E X -4

V E N T C A P

2" V T R

2" V T R

E X -5

HPU-2A

HPU-3A

E X -6

H B

H BB OI LE R

S T A C K

R D

ASC0

ASC0

ASC0 01

ASC0

ASC0 02

2" V T R

2" V T R

2" V T R

2" V T R

E X -8

V E N T C A P

ASC0 13

ASC0 14

ASC0 05

ASC0 06

ASC0

ASC0

V -3

V -2

E X -12

E X -10

V E N T C A P

V E N T C A P

2" V T R

2" V T R

2" V T R

E X -9

3" V T R

2" V T R

2" V T R

2" V T R

E X -11

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

2" V T R

ONL

Y

ONL

Y

ONLY

ONLY

ONL

Y

ONL

Y

ONLY

ONLY

X

X

X X X

X

X

GATE

G A T E

G A T E

GATE

GATE

G A T E

T R E X

G A T E

GATE

G A T E

GATE

GATE

GATE

G A T E

GATE

GATE

G A T E

G

AT

E

GATE

G A T E

G A T E

G A T E

GATE

G A T E

G A T E

G A T E

G A

TE

G A T E

GATE

G A T E

G A T E

GRASS

GATE

G A

TE

G

A

T

E

GATE

G A T E

G

A

T

E

G

A T

E

X X

R A Z O R

W

IR

E

O N

T O P

O F

A L L

F E N C E S

R A Z O R

W

IR

E

O N

T O P

O F

A L L

F E N C E S

X

RA

ZO

R W

IR

E O N

TOP

OF

ALL

FEN

C

ES

RAZO

R W

IRE

ON

TOP

OF

ALL

FENC

ES

X X

GATE

G A T E

G A T E

GATE

X

X

X

X

X

X

X

X

X

X

X

X

X

G A T E

G A T E

X

X

G A T E

GATE X

G A T E

X

GATE

X X

X

X

X

X X

X

X

BLDG. N

#3715

(KITCHEN/

LAUNDRY)

BLDG. A

#3741

BLDG. B

#3741

BLDG. D

#3741

BLDG. E

#3741

BLDG. F

#3741

BLDG. G

#3851

(HORIZON)

BLDG. H #3859

(GENESIS)

BLDG. C

BLDG. I #3883

(PHOENIX - B & C)

BLDG. I #3883

(PHOENIX - A)

BLDG. J

#3855 (BRC)

BLDG. K

(WHITCOMB)

BLDG. L

#3770 (FDC)

BLDG. U

#3776

BLDG. M

#3723 (IRM)

BLDG. O BLDG. P

BLDG. A

#3723 (SUPPORT)

BLDG.

#3722

BLDG.

#3869

S J O

H N

Y O

U N

G P

A R

K W

A Y

33RD STREET

LEGEND

SCOPE OF WORK

PROJECT SCOPE

VICINITY MAP

PROJECT

LOCATION

PROJECT DESIGN TEAM

RHODES+BRITO ARCHITECTS

605 E. ROBINSON ST, SUITE 750

ORLANDO, FL 32801

PH. (407) 648-7288

CONTACT: NAME

ARCHITECTURE

C&S COMPANIES

605 E. ROBINSON, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: ANDREA CELLA

STRUCTURE

A/R/C ASSOCIATES, INCORPORATED

601 N. FERN CREEK AVE., SUITE 100

ORLANDO, FL 32803

PH: (407) 896-7875

CONTACT: TROY GIBERT

ROOFING / WATERPROOFING

A C CT T SEH IR

AA0002809

BUILDINGS D, E & F

ROOF SAFETY RAILINGS

95% CD SUBMITTAL

03/14/2023

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY GOVERNMENT

CAPITAL PROJECTS DIVISION

400 EAST SOUTH STREET, SUITE 500

ORLANDO, FL 32801

G000.1

SCALE: 1 : 2000G000.1

A1 ARCHITECTURAL SITE PLAN

THE SCOPE IS TO PROVIDE FALL PROTECTION SAFETY

DEVICES AT VARIOUS LOCATIONS FOR ROOF AREAS ON

DESIGNATED BUILDINGS AT THE ORANGE COUNTY

CORRECTIONS CAMPUS. D (BUILDING), E (BUILDING) AND

F (BUILDING) ARE INCLUDED WITHIN THIS SCOPE OF

WORK.

WHILE THIS IS NOT A LIFE SAFETY ANALYSIS OF THE

ROOF AREAS, THE DESIGN TEAM WILL PROVIDE ROOF

FALL PROTECTION SYSTEMS ON BUILDINGS IDENTIFIED

UNDER THIS SCOPE OF WORK.

• FALL PROTECTION SYSTEMS WILL INCLUDE BUT NOT

LIMITED TO SAFETY RAILINGS, SINGLE PONT TIE-

OFFS, HORIZONTAL LIFELINES.

• SELECTIVE ROOF DEMOLITION

• ROOFING WILL BE LIMTED TO THE AREAS OF NEW

SAFETY RAILINGS, SINGLE PONT TIE-OFFS,

HORIZONTAL LIFELINES AND MECHANICAL UNIT

PLATFORMS AND ANY OTHER PENETRATIONS TO THE

EXISTING ROOF SYSTEM REQUIRED FOR

COMPLETION OF THIS SCOPE OF WORK.

• THERE WILL BE NO WORK PERFORMED TO ANY

EXISTING ROOF TOP MECHANICAL SYSTEMS OR ANY

OTHER EXISTING UTILITY UNDER THIS SCOPE.

DATE SUBMISSION / REVISION NO.

100%

NOT FOR CONSTRUCTION

CD REVIEW SUBMITTAL

SF

r h o d e s + b r i t o A R C H I T E C T S

4" TYP

UNO

0 8 20

100'-0"

FIN FLOOR

A

A101

A2

A711

A2

A711

MATERIALS LEGEND

DRAWING FORMAT

DIMENSIONING DRAWING SYMBOL LEGEND

(123)

ROOM

NAME

OFFICE

A101

A711A scale:

drawn:

check:

date:

project no:

2001.001

01.01.01 date submission/revision no.

Client Logo and

Project Title

ALL REPRODUCTION

AND INTELLECTUAL

PROPERTY RIGHTS

RESERVED

c

CLIENT LOGO HERE

KEY PLAN HERE

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

19.02

TYP

TYP

G1

E1

C1

A1 A3

C3

E3

G3

A5 A7 A9

C5

EACH SHEET IS DIVIDED INTO A GRID. AN ALPHA-NUMERIC GRID COORDINATE SYSTEM IS USED TO ORGANIZE THE DRAWING TITLES

DRAWING TITLES ARE NUMBERED ACCORDING TO ITS LOCATION ON THE GRID. THE LOWER LEFT HAND CORNER GRID OF THE

DRAWING IS USED AS THE IDENTIFICATION NUMBER (SEE DIAGRAM).

COLUMN CENTERLINE

PARTITIONS ARE DIMENSIONED TO FACE OF STUDS, FACE OF CMU AND FACE OF

BLOCK UNLESS

INDICATED OTHERWISE

DIMENSIONS ARE INDICATED ON DRAWINGS, DO NOT SCALE DRAWINGS

6.

7.

PARTITION

KEYNOTE REFERENCE

ELEVATION

REFERENCE

REVISION

IDENTIFICATION

PARTITION TYPE

IDENTIFICATION

WINDOW TYPE

REVISION NUMBER

(REFER TO TITLE

BLOCK)

TARGET ELEVATION

TARGET DESCRIPTION

WINDOW DESIGNATION

(REFER TO WINDOW

SCHEDULE)

REFERENCE NUMBER

PARTITION TYPE

(REFER TO PARTITION

TYPE DETAILS)A

GRAPHIC SCALE

ELEVATION

REFERENCE

MULTIPLE INTERIOR H7

S

A5.68 W E

N

INDICATES FEET

DRAWING ON WHICH

ELEVATION OCCURS

MULTIPLE ELEVATION

NUMBER

ELEVATION ORIENTATION

ON PLANS

WHEN A ROOM/BUILDING/OBJECT CENTERLINE IS INDICATED, ONLY ONE SIDE OF

ELEMENT MAY BE DIMENSIONED

PARTITIONS WITH FINISH FACE FLUSH WITH FINISH FACE OF COLUMN WILL NOT BE

DRAWN ON SMALL

SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

COLUMN CENTERLINE

PARTITION FINISH FACE ON COLUMN OR GRID LINE WILL NOT BE DIMENSIONED ON

SMALL SCALE

PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

PARTITIONS CENTERED ON COLUMNS OR GRID LINES WILL NOT BE DIMENSIONED ON

SMALL SCALE

PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

5.

4.

PARTITION

3.

B. AS DIMENSIONED

COLUMN CENTERLINE

PARTITION

DOOR LOCATION

DOORS ARE LOCATED BY ONE OF THE FOLLOWING:

A. ONE JAMB FACE LOCATED BY A PARTITION AT RIGHT ANGLE.

2.

1.

PARTITION

DOOR

INTERIOR

ELEVATION

REFERENCE

ACCESSORY

IDENTIFICATION

DOOR NUMBER

SPOT

ELEVATION

REFERENCE

TRUE

NORTH

ARROW

DOOR NUMBER

(SEE DOOR SCHEDULE)

TARGET ELEVATION

ACCESSORY TYPE

(REFER TO ACCESSORY

SCHEDULE)A

ELEVATION NUMBER

ELEVATION ORIENTATION

DRAWING ON WHICH

ELEVATION OCCURS

ROOM SPACE IDENTIFICATION NOTATION

BUILDING AREA

WALL SECTION

OR BUILDING

SECTION

REFERENCE

NUMBER

DRAWING ON WHICH

SECTION OCCURS

SECTION ORIENTATION

SECTION NUMBER

ROOM NAME

COLUMN

IDENTIFICATION

B

DETAIL

REFERENCE

A3.11

H6

COLUMN CENTERLINE

DRAWING ON WHICH

DETAIL OCCURS

DETAIL NUMBER

REVISION SYMBOLS

IDENTIFICATION

SPACE

REVISION AREA

REVISION NUMBER

SPACE NAME

SPACE NUMBER

NET ROOM AREA (SF)

DRAWING SHEET NUMBERS

SUBCATEGORY

SHEET NUMBER

ITEM

CATEGORY

DISCIPLINE:

L - Landscape

S - Structural

A - Architectural

P - Plumbing

E - Electrical

M - Mechanical (HVAC)

C - Civil

RIGID INSULATION

POROUS FILL

GYPSUM BOARD /

GROUT FILL

BATT INSULATION

STEEL

PLYWOOD

(OR GLULAM)

CONTINUOUS

ROUGH LUMBER

DISCONTINUOUS

ROUGH LUMBER

CONCRETE MASONRY UNITSFINISH LUMBER

CONCRETE

EARTH

PROJECT

NORTH

ARROW

BEXISTING COLUMN

IDENTIFICATION

LIST OF ABBREVIATIONS

MISCELLANEOUS CHANNEL

MECHANICAL/ELECTRICAL/PLUMBING

LAMINATED VENEER LUMBER

COMPT COMPARTMENT

BW

BVL

BOTH WAYS

BEVELED

BM

BSL

BS

BOT

BRK

BUR

BRG PL

BRG

BSMT

BO

BD

BLDG

BLK(G)

BIT

BET

BEL

BENCH MARK

BUILDING SETBACK LINE

BUILT UP ROOFING

BOTH SIDES

BEARING PLATE

BOTTOM OF

BASEMENT

BRICK

BEARING

BOTTOM

BITUMINOUS

BLOCK(ING)

BUILDING

BOARD

BETWEEN

BELOW

CP

CT

CYD

CORR

CRS

CR

CSMT

CENTER POINT

CUBIC YARD

COURSE(S)

CORRUGATED

CERAMIC TILE

CHROMIUM (PLATED)

CASEMENT

ADDENDUMADD

A/V

AUTO

ASPH

ASB

ARCH

APROX

ANOD

AP

AHU

A/E

ADD'D

ANC

ALUM

ALT

ADJ

ADH

AFF

ANCHOR(AGE)

AUDIO VISUAL

ACCESS PANEL

APPROXIMATE

ARCHITECT(URAL)

ANODIZED

ASBESTOS

ASPHALT

AUTOMATIC

AIR HANDLING UNIT

ARCHITECT/ENGINEER

ADDITIONAL

ABOVE FINISHED FLOOR

ADJUSTABLE

ADHESIVE

ALTERNATE

ALUMINUM

AD

AB

A/C

ACT

ACPL

AC

ACC

ABV

ACOUSTICAL

ACOUSTICAL PLASTER

ACOUSTICAL TILE

AIR CONDITIONING

ANCHOR BOLT

AREA DRAIN

ABOVE

ACCESS

CI CAST IRON

CNTRSNK

CO

CONN

CONT

CONTR

CONST

CONC

COL

CNTR

CLOS

CK

CJ

CMU

CLS

CLR

CIR

CLC

CIP

CONNECTION

COUNTERSINK

CONTRACT(OR)

CONTINUOUS

CONSTRUCTION

CLEAN OUT

CENTER

CONCRETE

COLUMN

CONTROL JOINT

CAST-IN-PLACE

CONC MASONRY UNIT

CLEAR(ANCE)

CLOSET

CAULK

CEILING

CLOSURE

CIRCLE

CG

C/C

CAT

CFT

CHAM

CHT

CB

CAB

CORNER GUARD

CENTER TO CENTER

CUBIC FOOT

CEILING HEIGHT

CAST BASIN

CATEGORY

CHAMFER

CABINET

MANHOLEMH

INVERTINV

FRP FIBERGLASS REINFORCED

PLASTICEJ EXPANSION JOINT

GALVANIZED STEEL SHEET

EQUIP

EXT

EXP

EX

EST

ESC

EWC

ENGR

EQ

ENCL

EMER

ELEV

EL

EP

ELEC

EQUIPMENT

EXPANDED(EXPANSION)

ELECTRIC WATER COOLER

EXTERIOR

EXISTING

ESTIMATE

ESCALATOR

ELECTRICAL POWERBOARD

ENGINEER

EQUAL

ENCLOSE(URE)

EMERGENCY

ELEVATOR

ELEVATION

ELECTRICAL

GKT GASKET(ED)

GP

GYP

GWB

GYPBD

GLAM

GL

GSS

GYPSUM WALL BOARD

GYPSUM BOARD

GLUE LAMINATED

GALVANIZED PIPE

GYPSUM

GLASS

GA

GI

GEN'L

GD

GB

GC

GALV

FURN

FT

FUT

FUR

FS

FTG

FRT

GALVANIZED IRON

GENERAL CONTRACTOR

GALVANIZED

GAUGE

GENERAL

GRADE

GRAB BAR

FURNITURE/FURNISHINGS

FIRE-RETARDANT

FOOT

FUTURE

FURRING

FULL SIZE

FOOTING

JT

KIT

KO

JC

JB

JF

JST

IPS

JOINT

KITCHEN

KNOCKOUT

JANITOR CLOSET

JUNCTION BOX

JOINT FILLER

IRON PIPE SIZE

JOIST

MIR

MISC

MIN

MTD

MO

MM

MT

MASONRY OPENING

MIRROR

MISCELLANEOUS

MILLIMETER

MINIMUM

METAL THRESHOLD

MOUNTED

FIRE-RESISTANT COATING

FIRE EXTINGUISHER CABINET

FINISHED FLOOR ELEVATION

EXTERIOR INSULATION & FINISH

SYSTEM

DISP DISPENSER

EB

EIFS

E

EA

DWR

DR

DN

DWG

DRB

DS

DIV DR

DTL

DL

DP

EXPANSION BOLT

EAST

EACH

DRAWER

DIVISION DOOR

DAMP PROOFING

DOOR

DOWN

DRAWING

DRAIN BOARD

DOWN SPOUT

DETAIL

DEAD LOAD

DEPT

DBL

DF

DH

DIM

DIA

DEP

DEMO

DRINKING FOUNTAIN

DEMOLISH, DEMOLITION

DEPARTMENT

DOUBLE

DIMENSION

DOUBLE HUNG

DIAGONAL

DEPRESSED

FF FACTORY FINISH

FR

FND

FPL

FRC

FP

FOS

FOF

FOM

FOC

FLUOR

FH

FJT

FLR

FLEX

FLG

FFE

FIN

FGL

FRAME(D)(ING)

FOUNDATION

FLOOR PLATE

FACE OF STUDS

FACE OF FINISH

FACE OF MASONRY

FACE OF CONCRETE

FIREPROOF

FLUORESCENT

FIRE HYDRANT

FLUSH JOINT

FIBERGLASS

FLOOR

FLEXIBLE

FLASHING

FINISH(ED)

FBO

FCO

FEC

FE

FA

FAS

FD

FB

FURNISHED BY OTHERS

FLOOR CLEAN OUT

FIRE EXTINGUISHER

FIRE ALARM

FASTEN, FASTENER

FLOOR DRAIN

FACE BRICK

INSULATED BY CONTRACTOR

HEATING/VENTILATING/AIR

CONDITIONING

HP HIGH POINT

INCL

INT

IBC

INFO

ID

INSUL

HR

HWH

HRDW

HWD

HD HT

HTG

HT

HVAC

HOT

WATER

HEATER

INCLUDE(D)(ING)

INFORMATION

INSIDE DIAMETER

INSULATION

INTERIOR

HARDWOOD

HEAD HEIGHT

HOUR

HARDWARE

HEATING

HEIGHT

HM

HB

HOR

HBD

HJT

HDR

HD

HC

HOLLOW METAL

HORIZONTAL

HARDBOARD

HEAD JOINT

HEAVY DUTY

HOLLOW CORE

HOSE BIBB

HEADER

LUMP SUMLS

MED

MEMB

MECH

MAS

MAT'L

MAX

MEP

MTL

MFR

LVR

LVL

MC

M

LT

MATERIAL

MECHANICAL

MEDIUM

MEMBRANE

MAXIMUM

MANUFACTURER

METAL

MASONRY

LOUVER

METER

LIGHT

LAV

LAM

LBL

LAB

LF

LH

LB

LL

LAVATORY

LAMINATE

LINEAR FOOT

LEFT HAND

LABORATORY

LAG BOLT

LIVE LOAD

LABEL

WROUGHT IRON

VINYL ASBESTOS TILE

WELDED WIRE FABRIC

WALL TO WALL

UNDERWRITERS LABORATORY

UNLESS NOTED OTHERWISE

VAPOR BARRIER

VINYL COMPOSITION TILE

WHEEL BUMPER

WATER REPELLENT

WATERPROOFING

WATER CLOSET

WHB

STANDARDSTD

ROOMRM

PRE CAST CONCRETEPCC

ROUGH OPENING

REVERSE(SIDE)

RIGHT OF WAY

RAIN WATER CONDUCTOR

POLYVINYL CHLORIDE

POUNDS PER CUBIC FOOT

POUNDS PER LINEAL FOOT

POUNDS PER SQUARE FOOT

POINT/PRESSURE TREATED

POUNDS PER SQUARE INCH

PROPERTY LINE/PLATE

PREFABRICATE(D)

PRE FINISHED

PLASTIC LAMINATE

PAIR/PROPOSAL REQUEST

PRELIMINARYPRELIM

PVC

PSF

PT

PSI

PRF

PTN

PVMT

PERFORMED

PARTITION

PAVEMENT

PLF

PLYWD

PREFAB

PNT

PR

POL

PLBG

PNL

PNTD

PLYWOOD

PAINT

POLISHED

PLUMBING

PANEL

PAINTED

PCF

PG

PL

PERIM

PH

PFN

PJ

PLAM

PLAS

PLATE GLASS

PERIMETER

PHASE

PANEL JOINT

PLASTER

RO

ROW

RVS

RWC

TOP OF MASONRY

TONGUE AND GROOVE

TOILET PARTITION

TOILET PAPER DISPENSER

THRES THRESHOLD

TR TRANSOM

TYPICAL

TELEVISION

TYP

TV

TOLERANCE

TOP OF

TOP OF STEEL

TOP OF WALL

TOILET

TOL

TO

TOM

TOS

TOW

TLT

TPTN

TPD

TOWEL BAR

TREAD

THICK(NESS)

TEMPORARY

TERRAZZO

TELEPHONE

TB

T

T&G

THK

TEMP

TER

TEL

SYSTEM

SYNTHETIC

SYMMETRY(ICAL)

SUSPENDED

STRUCTURAL

STORAGE

STEEL

SYS

SYN

SYM

SUS

STR

STOR

STL

WTW

WWF

WI

WSCT

WO

WM

WIN

WTH

WS

WR

WP

WAINSCOT

WITHOUT

WIRED MESH

WINDOW

WIDTH

WATER STOP

RUBBER BASE

REQUEST FOR INFO

ROOF HATCH

REFLECTED CEILING PLAN

REVISION(S),(D)

REFLECT(ED),(ING)

REFRIGERATOR

RAIN LEADER

REINFORCE(D),(ING)

QUARRY TILE

VERTICAL DATUM

NATIONAL GEODETIC

NOT APPLICABLE

NOT IN CONTRACT

OUTSIDE DIAMETER

NOT TO SCALE

OVERFLOW ROOF DRAIN

OPPOSITE HAND

PC

OV

OPP

ORD

OS

PRE CAST

OVERALL

OPPOSITE

OUTSIDE

OC

OFC

OH

OD

OPG

OH/OPH

ON CENTER

OFFICE

OVERHEAD

OPENING

NGVD

N

NA

NIC

NO

NOM

NTS

NORTH

NUMBER

NOMINAL

RADIUSRAD

RFI

RFH

RFG

REV

RES

RET

RH

RFL

RL

ROOFING

RESILIENT

RETURN

RIGHT HAND

REQ'D

RD

RB

RCP

REM

REF

REFR

REG

REINF

REQUIRED

ROOF DRAIN

REMOVE

REFERENCE

REGISTER

RA

R

QTR

QT

RETURN AIR

RISER

QUARTER

SLAB ON GRADE

STAINLESS STEEL

SPECIFICATION(S)

SHELVINGSH

STATION

SQUARE YARD

SQUARE INCH

SQUARE

SPECIAL

SPEAKER

SPACER

STA

SQ/YD

SQ/IN

SS

SQ

SPEC

SPL

SPK

SPCR

SEALER

STEEL JOIST

SHELVING

SOUND PROOF

SLEEVE

SIMILAR

SHEET

SHEATHING

SOG

SLR

SJ

SHELV

SP

SL

SIM

SHT

SHTH

SQUARE FOOT

SOUTH

STORM DRAIN

SOLID CORE

SHEET GLASS

SECTION

SCHEDULE

SAFETY GLASS

SF

S

SD

SC

SG

SECT

SCHED

SFGL

W/

WH

WB

WD

WG

W

WC

WITH

WALL HUNG

WOOD BASE

WOOD

WIRED GLASS

WEST

VAT

VEST

VB

VCT

VAR

VERT

VESTIBULE

VARNISH

VERTICAL

UNF

UR

UL

UNO

UC

UNFINISHED

URINAL

UNDERCUT

OPCI OWNER PROVIDED

CONTRACTOR INSTALLED

OPOI OWNER PROVIDED

OWNER INSTALLED

CPCI CONTRACTOR PROVIDED

CONTRACTOR INSTALLED

RECEP RECEPTIONIST

SECRETARYSECR

SECURITYSECU

AHJ AUTHORITY HAVING JURISDICTION

VOL VOLUME

FV FIELD VERIFIED

ARCHITECTURAL

REV. NO. SHEET NAME

A141D ROOF PLAN - BLDG D

A141E ROOF PLAN - BLDG E

A141F ROOF PLAN - BLDG F

A501.1 EXTERIOR DETAILS

A504 PHYSICAL CHARECTERISTICS SCHEDULE, GENERAL NOTES AND ROOF

COMPONENT FASTENING SCHEDULE

A505 FLASHING REPAIR DETAILS

Grand total: 6

GENERAL

REV. NO. SHEET NAME

G000.1 COVER SHEET

G001.1 GENERAL INFORMATION AND DRAWING INDEX

Grand total: 2

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

12" = 1'-0"

G001.1

GENERAL

INFORMATION AND

DRAWING INDEX

Checker

Author

03/14/2023

18019-0039

DATE

LICENSE NAME

LICENSE NUMBER

ROOF SAFETY

RAILINGS

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

95% CD SUBMITTAL

STRUCTURAL

REV. NO. SHEET NAME

S-001 GENERAL NOTES & ABBREVIATIONS

S-101 BUILDING D

S-102 BUILDING E

S-103 BUILDING F

S-501 DETAILS

Grand total: 5

DRAWING INDEX

DATE SUBMISSION/REVISION NO.

9'

0"

4' - 0" 4'

0"

4' - 0"

4' - 0"

11' - 0"

20' - 6"

12' - 0"

12' - 0"

15 15

11' - 10"

4' - 0" 5' - 0"

VIF

14' - 8"

V

IF

08 04

04 04

040404

22' - 0"

15' - 0"

V

IF

11' - 10"

50' - 0"

13' - 0"

4'

0"

4'

0"

13' - 0" 3' - 0" 8' - 10"

V

IF19

12' - 0"

3' - 0"

VIF

18' - 0"

8' - 0"

14' - 10"

4' - 0"

52' - 0"

14' - 0"

6' - 0"

16' - 0"

16' - 0"

32' - 0"

16' - 0" 2' - 8"

BUILDING E

(SEE SHEET A141E)

MAIN ROOF AREA

BUILDING D

RAISED ROOF

AREA

LOW ROOF AREA

LOW ROOF AREA

HIGH ROOF AREA

LEGEND

SINGLE POINT TIE OFF CENTER IDENTIFICATION

XX KEYNOTE IDENTIFICATION

HORIZONTAL LIFELINE

GUARDRAIL

GUARDRAILING GATE

EXISTING ROOF WALKWAY PADS, TO REMAIN

NEW ROOF WALKWAY PADS

EXISTING METAL ACCESS PLATFORMS, TO REMAIN

KEYPLAN

BLDG. A

BLDG. P

BLDG. B

BLDG. A

SUPPORT

BLDG. ?

BLDG. M

BLDG. H

BLDG. S

BLDG. I (B&C)BLDG. I (A)

BLDG. K

BLDG. U

BLDG. C

BLDG. D

BLDG. E

BLDG. F

BLDG. G

BLDG. J

BLDG. L

BLDG. N

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

As indicated

A141D

ROOF PLAN - BLDG D

Checker

Author

03/14/2023

18019-0039

DATE

LICENSE NAME

LICENSE NUMBER

ROOF SAFETY

RAILINGS

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

95% CD SUBMITTAL

SCALE: 3/32" = 1'-0"A141D

A3 ROOF PLAN - BLDG_D

DATE SUBMISSION/REVISION NO.

KEYNOTES

01 EXISTING ROOF SYSTEM AT MAIN AREA TO REMAIN

02 EXISTING ROOF SYSTEM AT LOW ROOF AREA TO REMAIN

03 EXISTING ROOF SYSTEM AT HIGH ROOF AREA TO REMAIN

04 EXISTING MECHANICAL EQUIPMENT TO REMAIN. NO ROOF EQUIPMENT

MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

07 EXISTING ROOF ACCESS HATCH TO REMAIN, TYP

08 EXISTING EQUIPMENTS PIPES & DUCTS, WHICHEVER APPLIES, TO REMAIN. NO

PIPER NOR DUCTS MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

12 SINGLE POINT TIE OFF LOCATION. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW STEEL POST, TYP. REFER TO SHEET A501

14 42" HIGH GUARD RAILING. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW VERTICAL POSTS, TYP. REFER TO SHEET A501

15 42" HIGH SELF CLOSING SWINGING GATE WITH SPRING LOADED HINGES AND

STEEL PLATE STOP, ATTACHED TO GUARD RAILING POST. REFER TO SHEET

A501

16 GALVANIZED STEEL ACCESS LADDER, REFER TO SHEET A501 AND

STRUCTURAL DRAWINGS. GC TO VIELD VERIFY LOCATION AND PREVENT

INTERFERENCE WITH EXISTING ROOF EQUIPMENT

GENERAL NOTES - ROOF

1 REFER TO OTHER DISICPLINES FOR ADDITIONAL SCOPE OF WORK NOT SHOWN

ON THIS PLAN.

2 THESE DRAWNGS HAVE BEEN DEVELPED FROM OBSERVED FIELD CONDITIONS

AND EXISTING DRAWINGS BUT MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE

CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY DRAWINGS WITH

EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT

IMMEDIATELY IF ANY CONFLICT EXISTS.

3 THIS FACILITY WILL REMAIN OPERATIONAL FOR THE DURATION OF THIS

PROJECT. THE GC SHALL ENSURE THE SAFETY OF ALL OCCUPANTS AND

PERSONNEL. DEMOLITION OF ITEMS WHICH MAY CREATE DUST, NOISE, OR

CIRCULATION PROBLEMS SHOULD BE COORODINATED WITH THE OWNER PRIOR

TO THE START OF WORK.

4 EXISTING ROOFS ARE MODIFIED BITUMENT UNLESS OTHERWISE INDICATED

5 THE CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE DURING DEMOLITION AND THROUGHOUT CONSTRUCTION. THE

CONTRACTOR SHALL BEAR ALL COSTS OF REPAIRING, REFINISHING,

REPLACING, ETC OF EXISTING ITEMS DAMAGED TO THEIR ORIGINAL STATE.

6 CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION AND NEW WORK. FOR

ADDITIONAL GENERAL NOTES, LEGENDS AND SCHEDULES REFER TO SHEET

G001

7 CONTRACTOR SHALL PROVIDE ENGINEERED SHOP DRRAWINGS FOR NEW

LADDERS, SAFETY RAILINGS AND GATES FOR REVIEW BY THE DESIGN TEAM

FOR APPROVAL PRIOR TO FABRICATION.

8 IF REQUIRED THE CONTRACOTR SHALL COORDINATE ALL SHUT DOWNS IN

UTILITY SERVICE WITH OWNER PRIOR TO PERFORMING SHUT DOWNS IN UTILITY

SERVICE.

9 CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL NEW PENETRATIONS

MADE THROUGH THE EXISTING ROOF SYSTEM ARE FLASHED TO A WATERTIGHT

CONDITION. CONTRACTOR SHALL COORDINATE WITH ROOFING DETAILS

PROVIDED.

10 CONTRACTOR SHALL COORDINATE WITH THE OWNER OF ANY CURRENT ROOF

WARRANTIES.

11 CONTRACTOR SHALL COORDINATE WITH OWNER CONCERNING THE PROPER

REMOVAL OF ALL CONSTRUCTION DEBRIS ASSOCIATED WITH THE WORK.

12 CONTRCATOR SHALL COORDINATE WITH THE OWNER CONCERNING THE HOURS

THAT CONSTRUCTION ACTIVITIES CAN TAKE PLACE.

13 IF ANY MATERIALS ARE SUSPECTED OF CONTAINING HAZARDOUS MATERIALS

ARE ENCOUNTERED, BO NOT DISTURB AND IMMEDIATELY NOTIFY THE

ARCHITECT AND OWNER. HAZARDOUS MATERIALS SHALL BE REMOVED BY THE

OWNER UNDER A SEPARATE CONTRACT.

14 ALL EXISTING LIGHTING PROTECTION IS TO REMAIN UNDISTURBED DURING

CONSTRUCTION

15 ALL EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN, CONNECTION SHALL

NOT BE DISTURBED IN ANY WAY AND MUST REMAIN OPERATIONAL AT ALL TIMES

16 ALL EXISTING ROOF WALKWAY PADS ARE TO REMAIN

BUILDING D

(SEE SHEET A141D)

BUILDING F

(SEE SHEET A141F)

9"

51' - 0"

85' - 0" 4' - 0"

4' - 0"

20' - 0"

" 0414

4'

0"

21' - 0"

21' - 0"4'

0"

4' - 0"

5' - 0"

10' - 0"

5' - 0"

10' - 0"

E Q

E Q

15' - 0"

LOW ROOF AREA

HIGH ROOF

AREA

MAIN ROOF AREA

BUILDING E

HIGH ROOF

AREA

HIGH ROOF

AREA

LOW ROOF

AREA

2' - 6"

14' - 0"

LEGEND

SINGLE POINT TIE OFF CENTER IDENTIFICATION

XX KEYNOTE IDENTIFICATION

HORIZONTAL LIFELINE

GUARDRAIL

GUARDRAILING GATE

EXISTING ROOF WALKWAY PADS, TO REMAIN

NEW ROOF WALKWAY PADS

EXISTING METAL ACCESS PLATFORMS, TO REMAIN

KEYPLAN

BLDG. A

BLDG. P

BLDG. B

BLDG. A

SUPPORT

BLDG. ?

BLDG. M

BLDG. H

BLDG. S

BLDG. I (B&C)BLDG. I (A)

BLDG. K

BLDG. U

BLDG. C

BLDG. D

BLDG. E

BLDG. F

BLDG. G

BLDG. J

BLDG. L

BLDG. N

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

As indicated

A141E

ROOF PLAN - BLDG E

Checker

Author

03/14/2023

18019-0039

DATE

LICENSE NAME

LICENSE NUMBER

ROOF SAFETY

RAILINGS

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

95% CD SUBMITTAL

SCALE: 3/32" = 1'-0"A141E

A4 ROOF PLAN - BLDG_E

DATE SUBMISSION/REVISION NO.

KEYNOTES

01 EXISTING ROOF SYSTEM AT MAIN AREA TO REMAIN

02 EXISTING ROOF SYSTEM AT LOW ROOF AREA TO REMAIN

03 EXISTING ROOF SYSTEM AT HIGH ROOF AREA TO REMAIN

04 EXISTING MECHANICAL EQUIPMENT TO REMAIN. NO ROOF EQUIPMENT

MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

06 EXISTING ACCESS LADDER TO REMAIN WITH NEW SAFETY GATE, TYP. REFER

TO SHEET A501

08 EXISTING EQUIPMENTS PIPES & DUCTS, WHICHEVER APPLIES, TO REMAIN. NO

PIPER NOR DUCTS MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

12 SINGLE POINT TIE OFF LOCATION. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW STEEL POST, TYP. REFER TO SHEET A501

14 42" HIGH GUARD RAILING. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW VERTICAL POSTS, TYP. REFER TO SHEET A501

16 GALVANIZED STEEL ACCESS LADDER, REFER TO SHEET A501 AND

STRUCTURAL DRAWINGS. GC TO VIELD VERIFY LOCATION AND PREVENT

INTERFERENCE WITH EXISTING ROOF EQUIPMENT

20 EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN, SEE GENERAL ROOF

NOTES FOR ADDITIONAL INFORMATION

GENERAL NOTES - ROOF

1 REFER TO OTHER DISICPLINES FOR ADDITIONAL SCOPE OF WORK NOT SHOWN

ON THIS PLAN.

2 THESE DRAWNGS HAVE BEEN DEVELPED FROM OBSERVED FIELD CONDITIONS

AND EXISTING DRAWINGS BUT MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE

CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY DRAWINGS WITH

EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT

IMMEDIATELY IF ANY CONFLICT EXISTS.

3 THIS FACILITY WILL REMAIN OPERATIONAL FOR THE DURATION OF THIS

PROJECT. THE GC SHALL ENSURE THE SAFETY OF ALL OCCUPANTS AND

PERSONNEL. DEMOLITION OF ITEMS WHICH MAY CREATE DUST, NOISE, OR

CIRCULATION PROBLEMS SHOULD BE COORODINATED WITH THE OWNER PRIOR

TO THE START OF WORK.

4 EXISTING ROOFS ARE MODIFIED BITUMENT UNLESS OTHERWISE INDICATED

5 THE CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE DURING DEMOLITION AND THROUGHOUT CONSTRUCTION. THE

CONTRACTOR SHALL BEAR ALL COSTS OF REPAIRING, REFINISHING,

REPLACING, ETC OF EXISTING ITEMS DAMAGED TO THEIR ORIGINAL STATE.

6 CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION AND NEW WORK. FOR

ADDITIONAL GENERAL NOTES, LEGENDS AND SCHEDULES REFER TO SHEET

G001

7 CONTRACTOR SHALL PROVIDE ENGINEERED SHOP DRRAWINGS FOR NEW

LADDERS, SAFETY RAILINGS AND GATES FOR REVIEW BY THE DESIGN TEAM

FOR APPROVAL PRIOR TO FABRICATION.

8 IF REQUIRED THE CONTRACOTR SHALL COORDINATE ALL SHUT DOWNS IN

UTILITY SERVICE WITH OWNER PRIOR TO PERFORMING SHUT DOWNS IN UTILITY

SERVICE.

9 CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL NEW PENETRATIONS

MADE THROUGH THE EXISTING ROOF SYSTEM ARE FLASHED TO A WATERTIGHT

CONDITION. CONTRACTOR SHALL COORDINATE WITH ROOFING DETAILS

PROVIDED.

10 CONTRACTOR SHALL COORDINATE WITH THE OWNER OF ANY CURRENT ROOF

WARRANTIES.

11 CONTRACTOR SHALL COORDINATE WITH OWNER CONCERNING THE PROPER

REMOVAL OF ALL CONSTRUCTION DEBRIS ASSOCIATED WITH THE WORK.

12 CONTRCATOR SHALL COORDINATE WITH THE OWNER CONCERNING THE HOURS

THAT CONSTRUCTION ACTIVITIES CAN TAKE PLACE.

13 IF ANY MATERIALS ARE SUSPECTED OF CONTAINING HAZARDOUS MATERIALS

ARE ENCOUNTERED, BO NOT DISTURB AND IMMEDIATELY NOTIFY THE

ARCHITECT AND OWNER. HAZARDOUS MATERIALS SHALL BE REMOVED BY THE

OWNER UNDER A SEPARATE CONTRACT.

14 ALL EXISTING LIGHTING PROTECTION IS TO REMAIN UNDISTURBED DURING

CONSTRUCTION

15 ALL EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN, CONNECTION SHALL

4' - 0"

10' - 0"

10' - 0"

V

IF

5' - 0" 58' - 0"

4' - 0"

50' - 0"

51' - 0"

13' - 0"

10' - 8" 4' - 0"

2' - 0"

13' - 0"

4'

0"

10' - 0"

14' - 0"

10' - 0" 4' - 0"

8' - 6"

E Q

E Q

BUILDING E

(SEE SHEET A141E)

BUILDING G

10' - 0"

6' - 0"

MAIN ROOF AREA

BUILDING F

LOW ROOF AREA

HIGH ROOF AREA

RAISED ROOF

AREA

5' - 0"

5' - 0"

10' - 0"

LOW ROOF

AREA

LOW ROOF AREA

3' - 0"

5' - 0"

LEGEND

SINGLE POINT TIE OFF CENTER IDENTIFICATION

XX KEYNOTE IDENTIFICATION

HORIZONTAL LIFELINE

GUARDRAIL

GUARDRAILING GATE

EXISTING ROOF WALKWAY PADS, TO REMAIN

NEW ROOF WALKWAY PADS

EXISTING METAL ACCESS PLATFORMS, TO REMAIN

KEYPLAN

BLDG. A

BLDG. P

BLDG. B

BLDG. A

SUPPORT

BLDG. ?

BLDG. M

BLDG. H

BLDG. S

BLDG. I (B&C)BLDG. I (A)

BLDG. K

BLDG. U

BLDG. C

BLDG. D

BLDG. E

BLDG. F

BLDG. G

BLDG. J

BLDG. L

BLDG. N

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

As indicated

A141F

ROOF PLAN - BLDG F

Checker

Author

03/14/2023

18019-0039

DATE

LICENSE NAME

LICENSE NUMBER

ROOF SAFETY

RAILINGS

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

95% CD SUBMITTAL

SCALE: 3/32" = 1'-0"A141F

A3 ROOF PLAN - BLDG_F

DATE SUBMISSION/REVISION NO.

KEYNOTES

01 EXISTING ROOF SYSTEM AT MAIN AREA TO REMAIN

02 EXISTING ROOF SYSTEM AT LOW ROOF AREA TO REMAIN

03 EXISTING ROOF SYSTEM AT HIGH ROOF AREA TO REMAIN

04 EXISTING MECHANICAL EQUIPMENT TO REMAIN. NO ROOF EQUIPMENT

MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

08 EXISTING EQUIPMENTS PIPES & DUCTS, WHICHEVER APPLIES, TO REMAIN. NO

PIPER NOR DUCTS MODIFICATIONS ARE PART OF THIS SCOPE OF WORK

10 EXISTING RAISED ROOF TO REMAIN. NO MODIFICATIONS TO ROOF ARE PART

OF THIS SCOPE OF WORK

12 SINGLE POINT TIE OFF LOCATION. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW STEEL POST, TYP. REFER TO SHEET A501

14 42" HIGH GUARD RAILING. REMOVE EXISTING ROOF SYSTEM ONLY AS

REQUIRED TO INSTALL NEW VERTICAL POSTS, TYP. REFER TO SHEET A501

GENERAL NOTES - ROOF

1 REFER TO OTHER DISICPLINES FOR ADDITIONAL SCOPE OF WORK NOT SHOWN

ON THIS PLAN.

2 THESE DRAWNGS HAVE BEEN DEVELPED FROM OBSERVED FIELD CONDITIONS

AND EXISTING DRAWINGS BUT MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE

CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY DRAWINGS WITH

EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT

IMMEDIATELY IF ANY CONFLICT EXISTS.

3 THIS FACILITY WILL REMAIN OPERATIONAL FOR THE DURATION OF THIS

PROJECT. THE GC SHALL ENSURE THE SAFETY OF ALL OCCUPANTS AND

PERSONNEL. DEMOLITION OF ITEMS WHICH MAY CREATE DUST, NOISE, OR

CIRCULATION PROBLEMS SHOULD BE COORODINATED WITH THE OWNER PRIOR

TO THE START OF WORK.

4 EXISTING ROOFS ARE MODIFIED BITUMENT UNLESS OTHERWISE INDICATED

5 THE CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE DURING DEMOLITION AND THROUGHOUT CONSTRUCTION. THE

CONTRACTOR SHALL BEAR ALL COSTS OF REPAIRING, REFINISHING,

REPLACING, ETC OF EXISTING ITEMS DAMAGED TO THEIR ORIGINAL STATE.

6 CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION AND NEW WORK. FOR

ADDITIONAL GENERAL NOTES, LEGENDS AND SCHEDULES REFER TO SHEET

G001

7 CONTRACTOR SHALL PROVIDE ENGINEERED SHOP DRRAWINGS FOR NEW

LADDERS, SAFETY RAILINGS AND GATES FOR REVIEW BY THE DESIGN TEAM

FOR APPROVAL PRIOR TO FABRICATION.

8 IF REQUIRED THE CONTRACOTR SHALL COORDINATE ALL SHUT DOWNS IN

UTILITY SERVICE WITH OWNER PRIOR TO PERFORMING SHUT DOWNS IN UTILITY

SERVICE.

9 CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL NEW PENETRATIONS

MADE THROUGH THE EXISTING ROOF SYSTEM ARE FLASHED TO A WATERTIGHT

CONDITION. CONTRACTOR SHALL COORDINATE WITH ROOFING DETAILS

PROVIDED.

10 CONTRACTOR SHALL COORDINATE WITH THE OWNER OF ANY CURRENT ROOF

WARRANTIES.

11 CONTRACTOR SHALL COORDINATE WITH OWNER CONCERNING THE PROPER

REMOVAL OF ALL CONSTRUCTION DEBRIS ASSOCIATED WITH THE WORK.

12 CONTRCATOR SHALL COORDINATE WITH THE OWNER CONCERNING THE HOURS

THAT CONSTRUCTION ACTIVITIES CAN TAKE PLACE.

13 IF ANY MATERIALS ARE SUSPECTED OF CONTAINING HAZARDOUS MATERIALS

ARE ENCOUNTERED, BO NOT DISTURB AND IMMEDIATELY NOTIFY THE

ARCHITECT AND OWNER. HAZARDOUS MATERIALS SHALL BE REMOVED BY THE

OWNER UNDER A SEPARATE CONTRACT.

14 ALL EXISTING LIGHTING PROTECTION IS TO REMAIN UNDISTURBED DURING

CONSTRUCTION

15 ALL EXISTING FIRE DEPARTMENT CONNECTION TO REMAIN, CONNECTION SHALL

TOP OF ROOF

STEEL PLATE ANCHORED

TO EXISTING CONCRETE

DECK, SEE STRUCT. DWGS

FOR DETAILS

REMOVE EXISTING ROOF

MEMBRANE AND

INSULATION AS REQUIRED

FOR STEEL PLATE & POST

INSTALATION

METAL FLASHING AROUND

POST, REFER TO SHEET

A505 FOR DETAILS

GALV. STEEL POST W/

STEEL CAP AND THREADED

ROD, SEE STRUCT. DWGS

FOR DETAILS

SWIVELING EYE

ATTACHMENT TO BE

PROVIDED BY THE FALL

PROTECTION

MANUFACTURER AND

ATTACHED TO THREADED

ROD

BY GC

TBD

ROOF INSULATION INFILL,

REFER TO SHEET A505 FOR

DETAILS

EXISTING ROOF SYSTEM TO

REMAIN

THREADED BOLT, REFER TO

STRUCT. DWGS FOR

DETAILS

GC NOTES:

1. PRIOR TO PURCHASING, CONTRACTOR SHALL COORDINATE WITH THE LIFELINE

MANUFACTURER TO INCLUDE ALL THE REQUIRED END ANCHORS, INTERMEDIATE

ANCHORS, BY-PASS ANCHORS, AND ALL REQUIRED 90 & 45 DEGREE WIRE CORNERS,

AS WELL AS ALL ACCESSORIES NEEDED FOR HORIZONTAL LIFELINE SYSTEM.

2. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS ON THE STEEL POST INCLUDING

BUT NOT LIMITED TO BASE PLATE FOR APPROVAL

GALV. STEEL

HORIZONTAL

RAILS, REFER TO

STRUCTURAL

DWGS TYP

GC NOTES:

1. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS

ON THE SAFETY RAILING SYSTEM INCLUDING BUT

NOT LIMITED TO SIZES, CONNECTIONS, SPACING,

AND ANY OTHER ELEMENTS TO THE ARCHITECT

FOR APPORVAL PRIOR TO FABRICATION.

2. SHOP DRAWING SHALL INCLUDE RAILING LAYOUT

IDENTIFYING EACH FITTING NEEDED INCLUDING

ANGLED FITTINGS IF NEEDED

5' - 0" MAX

GALV. STEEL

VERTICAL POST

GALV. PIPE

FITTING, TYP

EXISTING

ROOF LEVEL

TO REMAIN

EXISTING ROOF

DECK, TO

REMAIN, TYP

STEEL PLATE AT

BOTTOM OF EA

POST ATTACHED

TO DECK, SEE

STRUCUT, TYP

CORROTION

RESISTANT THREE

(3) SOCKET PIPE

FITTING

CORROTION

RESISTANT FOUR

(4) SOCKET PIPE

FITTING

SIDE ELEVATION

3/4" DIA STEEL RUNG,

TYP

V E

R

IF

Y I N

F

IE

L D

EXISTING ROOF,

TO REMAIN, TYP

STEEL CLIP ANGLE,

TYP

GC NOTES:

1. CONTRACTOR SHALL PROVIDE

SHOP DRAWINGS ON THE STEEL

LADDER INCLUDING BUT NOT

LIMITED TO SIZES, CONNECTIONS,

SPACING, AND ANY OTHER

ELEMENTS TO THE ARCHITECT FOR

APPORVAL PRIOR TO FABRICATION.

FLAT STEEL RAIL AT

EACH SIDE

OF FLAT

RAIL

M A

X

EXIST FACE OF

BUILDING

1' - 6"

E Q

E Q

7"

"6

FRONT ELEVATION

2' - 0"

E Q

E Q

FLAT STEEL RAIL

EXTENSION AT

EACH SIDE

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

As indicated

A501.1

EXTERIOR DETAILS

Checker

Author

03/14/2023

18019-0039

DATE

LICENSE NAME

LICENSE NUMBER

ROOF SAFETY

RAILINGS

3503 VISION BLVD

ORLANDO, FL 32839

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

95% CD SUBMITTAL

SCALE: 1 1/2" = 1'-0"A501.1

D9 SINGLE POINT ATTACHMENT DETAIL

SCALE: 1/2" = 1'-0"A501.1

F9 TYPICAL SECURITY RAILING DETAIL

SCALE: 1/2" = 1'-0"A501.1

A9 LADDER DETAIL

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

BUILDINGS D, E & F

ORANGE COUNTY

GOVERNMENT

CAPITAL PROJECTS

DIVISION

605 E. Robinson Street, Suite 210 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

R

S-001

GENERAL NOTES AND

ABBREVIATIONS

A. CELLA, P.E.

A. CELLA, P.E.

3/14/2023

L68.074.001

ROOF SAFETY

RAILINGS

3503 VISION BLVD,

ORLANDO, FL 32839

100% CONSTRUCTION DOCUMENTS

D.1 D.2 D.3 D.4 D.5 D.6 D.7

RISK CATEGORY

SEISMIC IMPORTANCE FACTOR

SS = 0.085

SITE CLASS

Sds = 0.075

SEISMIC DESIGN CATEGORY = A

SEISMIC RESPONSE COEFFICIENT, Cs

III

1.25 S1 = 0.036 D Sd1 = 0.051

RESPONSE MODIFICATION COEFFICIENT, R = 3

0.0308

D. SEISMIC

SITE EXPOSURE CATEGORY

INTERNAL PRESSURE COEFFICIENT

WIND-BORNE DEBRIS REGION

B ±0.18

NO

C.1 ULTIMATE WIND SPEED

BUILDING RISK CATEGORY

144 MPH

III

C. WIND LOAD (3-SEC. GUST)

150 LB CONCENTRATED LATERAL OR VERTICAL LOAD AT MID RAIL

200 LB CONCENTRATED LATERAL OR VERTICAL LOAD AT TOP RAIL

B.5 ROOF GUARDRAIL 20 PLF AT TOP OF RAIL (NON-PULBIC AREAS)

B.4 ROOF ELEVATED WALKWAY PLATFORMS 60 PSF

B.3 ROOF ACCESS LADDER 60 PSF

B.2 LIFELINE SUPPORT LOAD 3,100 LBS x (1.6 FACTOR)

B.1 SINGLE POINT ANCHOR FALL ARREST LOAD 3,100 LBS x (1.6 FACTOR)

B. FALL ARREST AND LIFELINE LIVE LOADS:

2. FBC DESIGN DATA:

A. ROOF LIVE LOAD: 20 PSF

1. CODES AND REFERENCE STANDARDS: FLORIDA BUILDING CODE (FBC) - 2020 7TH EDITION

PART IA - DESIGN CRITERIA

11. THIS STRUCTURE IS A THRESHOLD BUILDING AS DEFINED BY THE FLORIDA BUILDING CODE.

10. FOR ELEVATIONS REFER TO THE PLAN SHEETS.

9. FABRICATION PRIOR TO THE RECEIPT OF APPROVED SHOP DRAWINGS SHALL BE AT THE CONTRACTOR'S OWN RISK AND THAT INSTALLATION OF ANY WORK PRIOR TO RECEIPT OF AN APPROVED SHOP DRAWING SHALL BE STRUCTURALLY

PROHIBITED.

8. THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR ALL PARTS OF THE WORK INCLUDING DESCRIPTION OF DEMOLITION, TEMPORARY BRACING, CONSTRUCTION METHODS AND SEQUENCING, WHERE APPLICABLE NO PERFORMANCE

OF WORK SHALL COMMENCE WITHOUT REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER.

7. DO NOT SCALE DRAWING DIMENSIONS. IN THE EVENT OF A GRID LINE DIMENSION CONFLICT, THE ARCHITECTURAL

DRAWINGS SHALL GOVERN.

6. TYPICAL NOTES AND DETAILS SHOWN ON STRUCTURAL TYPICAL DETAILS SHALL BE APPLICABLE TO ALL PARTS OF THE STRUCTURAL WORK EXCEPT WHERE SPECIFICALLY REQUIRED OTHERWISE ON THE CONTRACT DOCUMENTS. DETAILS NOT SPECIFICALLY SHOWN SHALL BE SIMILAR TO THOSE SHOWN FOR THE MOST NEARLY SIMILAR CONDITION ON THE DRAWINGS

AS DETERMINED BY THE ENGINEER.

5. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PROCEDURES. THE STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR MEANS AND METHODS OF

CONSTRUCTION OR FOR RELATED SAFETY PRACTICES.

4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, TIE-DOWNS, AND/OR SHORING MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE

PROJECT.

3. THE CONTRACTOR SHALL COORDINATE THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATIONS NOT INDICATED ON THE STRUCTURAL DRAWINGS. SUCH INFORMATION INCLUDES, AS A MINIMUM, SPECIAL CONNECTIONS, MISCELLANEOUS DETAILS, SPECIAL FINISHES, OPENINGS IN STRUCTURAL ELEMENTS, ETC.

2. WORK ON STRUCTURAL DRAWINGS REPRESENTS FINAL CONDITIONS CONTRACTOR SHALL BE RESPONSIBLE FOR THE

STRUCTURAL STABILITY OF ALL INTERMEDIATE CONDITIONS DURING CONSTRUCTION.

1. THE CONTRACTOR IS RESPONSIBLE FOR THE SURVEY AND FIELD VERIFYING ALL EXISTING CONDITIONS.

THE FOLLOWING REQUIREMENTS TOGETHER WITH THE PROJECT PLANS AND SPECIFICATIONS SHALL APPY TO THE STRUCTURES

IN THIS CONTRACT:

PART IB - GENERAL

4. INSTALLATION OF ADHESIVE ANCHORS SHALL BE PERFORMED BY PERSONNEL CERTIFIED BY AN APPLICABLE CERTIFICATION PROGRAM. CERTIFICATION SHALL INCLUDE TESTS IN ACCORDANCE WITH THE ACI/CRSI ADHESIVE ANCHOR

INSTALLER CERTIFICATION PROGRAM OR EQUIVALENT.

3. ALL POST INSTALLED ANCHOR PRODUCTS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S

INSTALLATION PROCEDURES.

2. ALL POST INSTALLED ANCHORS INTO PLACED & CURED CONCRETE OR GROUTED MASONRY, USE HILTI HIT-HY 200

INJECTION ADHESIVE ANCHOR (OR APPROVED EQUAL), UNLESS NOTED OTHERWISE.

1. FOR ALL POST INSTALLED ANCHORS INTO UNGROUTED MASONRY, USE HILTI HIT-HY 70 SYSTEM OR APPROVED EQUAL.

PART IV - POST INSTALLED ANCHORS

WWR WELDED WIRE REINFORCEMENT

WF WIDE FLANGE

VIF VERIFY IN FIELD

VERT VERTICAL

UNO UNLESS NOTED OTHERWISE

T/WALL TOP OF WALL ELEVATION

T/SLAB TOP OF SLAB ELEVATION

T/S TOP OF STEEL ELEVATION

T/PILE TOP OF PILE ELEVATION

T&B TOP AND BOTTOM

SSR SHEAR STUD REINFORCEMENT

SOG SLAB ON GRADE

SIM SIMILAR

STD STANDARD

SCHED SCHEDULE

RO ROUGH OPENING

REINF REINFORCING

PL PLATE

OCEW ON CENTER, EACH WAY

OC ON CENTER

MO MASONRY OPENING

LOC LOCATION

JT JOINT

HORIZ HORIZONTAL

GALV GALVANIZED

F.S. FAR SIDE (PLATE ON FAR SIDE OF PANEL)

FF FINISH FLOOR

FD FLOOR DRAIN

EXP EXPANSION

EXIST EXISTING

EW EACH WAY

EQ EQUAL

EOR ENGINEER OF RECORD

EMBED EMBEDMENT

EL ELEVATION

EFEW EACH FACE, EACH WAY

EF EACH FACE

DWGS DRAWINGS

DIA DIAMETER

COORD COORDINATE

COL COLUMN

CONT CONTINUOUS

CMU CONCRETE MASONRY UNIT

CL CENTERLINE

BTM BOTTOM

BPE BOTTOM OF PILE ELEVATION

BP BASE PLATE

B/S BOTTOM OF STEEL

ASD ALLOWABLE STRESS DESIGN

AFF ABOVE FINISH FLOOR

ADDL ADDITIONAL

MARK MEANING

ABBREVIATION TABLE

11.8 DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS

11.7 JOINT BROUGHT TO THE SNUG-TIGHT OR PRE-TENSIONED CONDITION

11.6 FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHER (IF REQUIRED) ARE POSITIONED AS REQUIRED

11.5 PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS

11.4 PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL

11.3 PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH)

11.2 FASTENER MARKED IN ACCORDANCE WITH ASTM REQUIREMENT

11.1 MANUFACTURER CERTIFICATION AVAILABLE FOR FASTENER MATERIALS

11. INSPECTION TASKS FOR BOLTED CONNECTIONS:

10.15 DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER

10.14 WELDS MEET VISUAL ACCEPTANCE CRITERIA

10.13 SIZE, LENGTH, AND LOCATION OF WELDS

10.12 WELDS CLEANED

10.11 VERIFY WELDING TECHNIQUES

10.10 VERIFY WPS FOLLOWED

10.9 NO WELDING OVER CRACKED TACK WELDS

10.8 CONTROL OF HANDLING OF WELDING CONSUMABLES

10.7 USE OF QUALIFIED WELDERS

10.6 CHECK WELDING EQUIPMENT

10.5 FIT UP GROOVE WELDS (INCLUDING JOINT GEOMETRY) AND FIT UP OF FILLET WELDS

10.4 WELDER IDENTIFICATION SYSTEM

10.3 MATERIAL IDENTIFICATION (TYPE/GRADE)

10.2 MANUFACTURER CERTIFICATION FOR WELDING CONSUMABLES AVAILABLE

10.1 WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE

10. INSPECTION TASKS FOR WELDED CONNECTIONS:

9. IN ACCORDANCE WITH SECTION 553.79 (7)A OF THE FLORIDA STATUTES, THE SPECIAL INSPECTOR SHALL, UPON COMPLETION OF THE BUILDING AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, FILE A SIGNED AND SEALED STATEMENT WITH THE ENFORCEMENT AGENCY IN SUBSTANTIALLY THE FOLLOWING FORM: TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE CONSTRUCTION OF ALL STRUCTURAL LOAD BEARING COMPONENTS DESCRIBED IN THE THRESHOLD INSPECTION NOTES COMPLIES WITH THE PERMITTED DOCUMENTS, SUBMITTED TO THE ENFORCEMENT

AGENCY.

8. THE SPECIAL INSPECTOR SHALL SUBMIT WRITTEN REPORTS TO THE ENFORCING AGENCY HAVING JURISDICTION FOR THE PROJECT EACH WEEK DURING CONSTRUCTION. IN ADDITION, THE SPECIAL INSPECTOR SHALL SUBMIT COPIES OF HIS REPORT TO THE OWNER, ARCHITECT, ENGINEER AND CONTRACTOR. THE REPORT WILL DESCRIBE CONSTRUCTION PROGRESS FOR THE WEEK AND ALL CONDITIONS THAT WERE NOT IN COMPLIANCE AS DESCRIBED ABOVE. THE REPORT SHALL ALSO STATE WHETHER ANY MEASURES WERE TAKEN BY THE CONTRACTOR TO CORRECT THESE CONDITIONS.

THE REPORT SHALL INCLUDE AN EXCEPTIONS AND CORRECTIONS LOG WITH A REQUIRED CORRECTIVE ACTION

COLUMN FOR EACH NON-CONFORMANCE ITEM.

7. THE SPECIAL INSPECTOR SHALL KEEP AN EXCEPTIONS AND CORRECTIONS FILE FOR FOLLOW-UP. THE EXCEPTIONS LOG SHALL BE SUBMITTED WITH THE WEEKLY REPORT. THIS FILE SHALL BE REVIEWED ON A DAILY BASIS AND UPDATED BY

THE SPECIAL INSPECTOR AS EXCEPTIONS ARE RECTIFIED.

6. THE CONTRACTOR SHALL, UPON BEING INFORMED BY THE SPECIAL INSPECTOR, IMMEDIATELY CAUSE TO ELIMINATE SUCH

DISCREPANCIES AND DEVIATIONS.

5. A SPECIAL INSPECTION PLAN IS NOT REQUIRED.

4. THIS INSPECTION DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO CARRY OUT QUALITY CONTROL INSPECTIONS AND TESTING. THE CONTRACTOR'S CONTRACTUAL OR STATUTORY OBLIGATIONS ARE NOT

RELIEVED BY ANY ACTION OF THE SPECIAL INSPECTOR.

3. ONLY ARCHITECTS AND ENGINEERS CERTIFIED BY THE STATE OF FLORIDA AS SPECIAL INSPECTORS OF THRESHOLD BUILDINGS CAN ASSUME THE RESPONSIBILITIES OF A SPECIAL INSPECTOR. THE SPECIAL INSPECTOR SHALL BE PERMITTED TO SEND HIS OR HER DULY AUTHORIZED REPRESENTATIVE TO THE JOB SITE TO PERFORM THE NECESSARY INSPECTIONS PROVIDED ALL REQUIRED WRITTEN REPORTS ARE PREPARED BY AND BEAR THE SEAL OF THE SPECIAL

INSPECTOR AND ARE SUBMITTED TO THE ENFORCEMENT AGENCY.

2. THE CONTRACTOR SHALL COOPERATE WITH AND ASSIST THE SPECIAL INSPECTOR IN PERFORMING INSPECTION DUTIES AS SPECIFIED BELOW. THE SPECIAL INSPECTOR AND ANY REPRESENTATIVE SHALL HAVE FREE ACCESS TO THE PROJECT AT ALL TIMES. THE CONTRACTOR SHALL REVIEW AND COORDINATE THE SCHEDULE OF WORK TO ACCOMMODATE THE REQUIRED INSPECTIONS. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF TWENTY-FOUR (24)

HOUR NOTICE TO THE SPECIAL INSPECTOR FOR ALL INSPECTIONS.

1. THE SPECIAL INSPECTION SERVICES AS DESCRIBED HEREIN WILL BE RETAINED BY THE OWNER. THE CONTRACTOR SHALL BE FAMILIAR WITH THE SCOPE OF THE INSPECTIONS THAT WILL BE PERFORMED AND ALSO THE REQUIREMENTS OF THE CONTRACTOR AS DESCRIBED BELOW. THE OWNER WILL PAY ALL COSTS OF EMPLOYING A SPECIAL INSPECTOR, BUT THE SPECIAL INSPECTOR SHALL BE RESPONSIBLE TO THE ENFORCEMENT AGENCY.

PART VII - TESTING AND INSPECTIONS

4. THERMALLY CUT EDGES SHALL BE FREE OF GOUGES GREATER THAN 3/16" DEEP AND SHARP V-SHAPED NOTCHES. GOUGES DEEPER THAN 3/16" AND NOTCHES SHALL BE REMOVED BY GRINDING OR REPAIRED BY WELDING.

3. THERMAL CUTTING SHALL MEET THE REQUIREMENTS OF AWS D1.1, SECTIONS 5.15.1.2, 5.15.4.3 AND 5.15.4.4.

2. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING OF EXISTING STRUCTURE INCLUDING BRACING OR STRUCTURAL SUPPORT TO PRESERVE STABILITY AND PREVENT UNEXPECTED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING

DEMOLISHED AND/OR SUPPLEMENTED

1. UNLESS OTHERWISE NOTED, DEMOLITION WASTE BECOMES THE PROPERTY OF THE CONTRACTOR.

PART II - DEMOLITION

17. STRUCTURAL STEEL EXPOSED TO THE WEATHER OR LOCATED IN A NONCONDITIONED SPACE, SHALL BE HOT DIPPED

GALVANIZED.

16. FIELD CUTTING OF STRUCTURAL STEEL OR ANY FIELD MODIFICATION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN

APPROVAL BY THE ENGINEER FOR EACH INDIVIDUAL CASE.

15. MINIMUM SIZE OF FILLET WELDS SHALL BE 1/4 INCH UNLESS OTHERWISE NOTED.

14. ANCHOR BOLTS OR RODS SHALL BE BUILT INTO CONNECTING WORK PRESET BY TEMPLATES OR SIMILAR METHODS.

13. WHERE A GROOVE WELD IS SHOWN WITHOUT AN INDICATED DEPTH OF PENETRATION THE JOINT SHALL BE A COMPLETE

JOINT PENETRATION WELD (CJP).

12. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES, UNLESS OTHERWISE NOTED.

11. TO OBTAIN SPECIFIED ALIGNMENT AND FIT-UP UNLESS NOTED OTHERWISE FIELD WELDING MUST BE PERFORMED WHERE SPECIFICALLY NOTED. EDGE OF SLAB AND ROOF BENT PLATES, ANGLES AND OTHER MISC EXTERIOR OR INTERIOR WALL ALIGNMENT ITEMS SHALL BE FIELD WELDED TO BEAMS. PROVIDED FABRICATIONS AND ERECTION TOLERANCES MORE STRINGENT THAN SPECIFIED BY AISC WHERE REQUIRED TO ACHIEVE THE DETAILS INDICATED.

10. ALL WELDING SHALL CONFORM WITH THE LATEST EDITION OF AWS CODE. ALL WELDERS (SHOP & FIELD) SHALL BE AWS D1/1

CERTIFIED FOR THE TYPE OF WELDING BEING PERFORMED.

9. USE WELDED OR BOLTED SHOP CONNECTIONS AND BOLTED FIELD CONNECTIONS WHERE POSSIBLE.

7. PIPE SECTIONS - ASTM A53 GRADE B.

6. ALL ANCHOR RODS SHALL BE ASTM F1554, GRADE 55, UNLESS OTHERWISE NOTED.

5. ALL STRUCTURAL BOLTS SHALL BE ASTM A-325 TYPE N UNLESS OTHERWISE NOTED.

4. ANGLES, PLATES, AND BARS - ASTM A36, (EXCEPT WHERE NOTED TO BE ASTM A572-50).

3. SQUARE, RECTANGULAR & ROUND HOLLOW STRUCTURAL SECTIONS (HSS) - ASTM A500 GRADE C.

2. WIDE FLANGE SECTIONS AND TEES - ASTM A992 (Fy = 50 KSI).

DESIGN - AISC 360, LATEST EDITION

CONSTRUCTION - AISC 303, LATEST EDITION

BOLTED CONNECTIONS - LATEST EDITION OF AISC SPECIFICATIONS FOR STRUCTURAL JOINTS

USING ASTM A325 BOLTS

WELDING CONNECTIONS - AMERICAN WELDING SOCIETY (AWS) D1.1, LATEST EDITION

1. STANDARDS:

PART III - STRUCTURAL STEEL

5. TESTING BY THIRD PARTY INDEPENDENT TESTING AGENCY SHALL BE PERFORMED FOR EACH BUILDING WITH STRUCTURAL COMPONENTS ATTACHING TO A CONCRETE ROOF SLAB TO VERIFY ASSUMED (f'c) COMPRESSION STRENGTH AND CONCRETE TYPE (NORMAL WEIGHT OR LIGHT WEIGHT). REPORTS OF TESTING SHALL BE SUBMITTED TO EOR FOR

APPROVAL PRIOR TO FABRICATION OF ANY STEEL COMPONENTS.

4. THE OMISSION FROM THE SHOP DRAWINGS OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS TO BE FURNISHED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF FURNISHING AND INSTALLING SUCH MATERIALS REGARDLESS OF WHETHER THE SHOP DRAWINGS HAVE BEEN REVIEWED AND APPROVED.

3. THE CONTRACTOR SHALL PREPARE A LIST AND SCHEDULE OF ALL STRUCTURAL SUBMITTALS PRIOR TO THE

CONSTRUCTION KICK-OFF MEETING FOR REVIEW BY THE STRUCTURAL EOR.

2. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER AND HAVE THE ENGINEER'S SHOP DRAWING

STAMP AFFIXED PRIOR TO FABRICATION.

1. THE GENERAL CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS BEFORE SUBMITTING FOR REVIEW.

PART V - SUBMITTALS

E. IN ACCORDANCE WITH SECTION 553.79 (7)A OF THE FLORIDA STATUTES, THE SPECIAL INSPECTOR SHALL, UPON COMPLETION OF THE BUILDING AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, FILE A SIGNED AND SEALED STATEMENT WITH THE ENFORCEMENT AGENCY IN SUBSTANTIALLY THE FOLLOWING FORM: TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE CONSTRUCTION OF ALL STRUCTURAL LOAD BEARING COMPONENTS DESCRIBED IN THE THRESHOLD INSPECTION PLAN COMPLIES WITH THE PERMITTED DOCUMENTS SUBMITTED TO THE ENFORCEMENT

AGENCY.

D. NOTE CHANGES IN WORKING SEQUENCE OR MATERIALS AND ANY UNUSUAL CIRCUMSTANCES AFFECTING THE

PERFORMANCE OF WORK.

C. IDENTIFY WORKING CONDITIONS INCLUDING WEATHER, TEMPERATURE, TIME OF DAY, AND TYPE AND LOCATION OF

WORK BEING PERFORMED.

B. THE SPECIAL INSPECTOR SHALL KEEP AN EXCEPTIONS AND CORRECTIONS FILE FOR FOLLOW-UP. THE EXCEPTIONS LOG SHALL BE SUBMITTED WITH THE WEEKLY REPORT. THIS FILE SHALL BE REVIEWED ON A DAILY BASIS AND UPDATED BY

THE SPECIAL INSPECTOR AS EXCEPTIONS ARE RECTIFIED.

A. THE SPECIAL INSPECTOR SHALL SUBMIT WRITTEN REPORTS TO THE ENFORCING AGENCY HAVING JURISDICTION FOR THE PROJECT EACH WEEK DURING CONSTRUCTION. IN ADDITION, THE SPECIAL INSPECTOR SHALL SUBMIT COPIES OF HIS REPORT TO THE OWNER, ARCHITECT, ENGINEER AND CONTRACTOR. THE REPORT WILL DESCRIBE CONSTRUCTION PROGRESS FOR THE WEEK AND ALL CONDITIONS THAT WERE NOT IN COMPLIANCE AS DESCRIBED ABOVE. THE REPORT SHALL ALSO STATE WHETHER ANY MEASURES WERE TAKEN BY THE CONTRACTOR TO CORRECT THESE CONDITIONS.

THE REPORT SHALL INCLUDE AN EXCEPTIONS AND CORRECTIONS LOG WITH A REQUIRED CORRECTIVE ACTION

COLUMN FOR EACH NON-CONFORMANCE ITEM.

REPORTING

PERIODIC: PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT

THE COMPLETION OF THE WORK

CONTINUOUS: COMPLETE INSPECTION OF EVERY PART OF THE WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING

PERFORMED AND AT THE COMPLETION OF THE WORK

9. DEFINITIONS:

8. THE SPECIAL INSPECTOR SHALL CONTACT THE ENGINEER ONCE A WEEK TO REVIEW DETAILS ON THE PROJECT AND TO

CONFIRM SPECIAL INSPECTOR HAS REVIEWED ALL APPROVED RFI'S, FCR'S, SKETCHES, ETC.

7. THE CONTRACTOR SHALL, UPON BEING INFORMED BY THE SPECIAL INSPECTOR, IMMEDIATELY CAUSE TO ELIMINATE SUCH

DISCREPANCIES AND DEVIATIONS.

6. THE SPECIAL INSPECTOR SHALL IMMEDIATELY ALERT THE CONTRACTOR OF ALL DISCREPANCIES AND DEVIATIONS FROM

THE CONTRACT DOCUMENTS.

5. THE SPECIAL INSPECTOR SHALL COOPERATE WITH THE CONTRACTOR AND SHALL REFRAIN FROM DIRECTING WORK, AS

THIS IS EXPRESSLY NOT PART OF THE SPECIAL INSPECTION FUNCTION.

4. THE CONTRACTOR SHALL ADVISE THE SPECIAL INSPECTOR IN ADVANCE OF CONSTRUCTION SCHEDULES AND PLANNED

OPERATIONS IN ORDER TO ASSURE TIMELY AND APPROPRIATE INSPECTION.

3. OTHER INSPECTIONS: A REPRESENTATIVE MUST SPEND ADEQUATE TIME TO THOROUGHLY INSPECT THE WORK AS

DESCRIBED HEREIN.

2. STRUCTURAL STEEL: A REPRESENTATIVE MUST PERIODICALLY INSPECT THE WORK AS DESCRIBED HEREIN.

b. A REPRESENTATIVE MUST BE PRESENT TO REVIEW THE INSTALLATION OF THE POST INSTALLED ANCHORS FOR CONFORMANCE WITH THE MANUFACTURER INSTALLATION INSTRUCTION AND THE STRUCTURAL DRAWINGS.

a. A REPRESENTATIVE MUST BE PRESENT TO REVIEW THE DRILLING AND CLEANING FOR THE INSTALLATION OF THE POST INSTALLED ANCHORS FOR CONFORMANCE WITH THE MANUFACTURER INSTALLATION INSTRUCTION

AND THE STRUCTURAL DRAWINGS.

1. POST INSTALLED ANCHOR INSTALLATION:

B. THE FOLLOWING MINIMUM DAILY ON-SITE INSPECTION SCHEDULE SHALL BE ADHERED TO BY THE SPECIAL

INSPECTOR'S REPRESENTATIVE:

A. THE SPECIAL INSPECTOR SHALL PERFORM SITE VISITS AT A FREQUENCY DETERMINED BY HIM/HER TO SATISFY THEMSELVES THAT THE INSPECTIONS ARE BEING PERFORMED BY HIS ON-SITE REPRESENTATIVE(S) IN ACCORDANCE

WITH THIS PLAN.

PROCEDURES AND SCHEDULE

G. THE SPECIAL INSPECTOR SHALL CONFIRM OR VERIFY THAT A PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF FLORIDA, WHO SPECIALIZES IN SHORING DESIGN INSPECTS THE SHORING AND RESHORING DURING CONSTRUCTION

FOR CONFORMANCE WITH PLANS SUBMITTED TO THE ENFORCING AGENCY.

F. THE CONTRACTOR SHALL COOPERATE WITH AND ASSIST THE SPECIAL INSPECTOR IN PERFORMING HIS INSPECTION DUTIES AS SPECIFIED BELOW. THE SPECIAL INSPECTOR AND HIS REPRESENTATIVE SHALL HAVE FREE ACCESS TO THE PROJECT AT ALL TIMES. THE CONTRACTOR SHALL REVIEW THIS PLAN AND COORDINATE THE SCHEDULE OF WORK TO ACCOMMODATE THE REQUIRED INSPECTIONS. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF TWENTY-FOUR (24)

HOUR NOTICE TO THE SPECIAL INSPECTOR FOR ALL INSPECTIONS.

E. ONLY ARCHITECTS AND ENGINEERS CERTIFIED BY THE STATE OF FLORIDA AS SPECIAL INSPECTORS OF THRESHOLD BUILDINGS CAN ASSUME THE RESPONSIBILITIES OF A SPECIAL INSPECTOR. THE SPECIAL INSPECTOR SHALL BE PERMITTED TO SEND HIS OR HER DULY AUTHORIZED REPRESENTATIVE TO THE JOB SITE TO PERFORM THE NECESSARY INSPECTIONS PROVIDED ALL REQUIRED WRITTEN REPORTS ARE PREPARED BY AND BEAR THE SEAL OF THE SPECIAL

INSPECTOR AND ARE SUBMITTED TO THE ENFORCEMENT AGENCY.

D. THIS INSPECTION DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO CARRY OUT HIS OWN QUALITY CONTROL INSPECTIONS AND TESTING. THE CONTRACTOR'S CONTRACTUAL OR STATUTORY OBLIGATIONS ARE NOT

RELIEVED BY ANY ACTION OF THE SPECIAL INSPECTOR.

C. THE SPECIAL (THRESHOLD) INSPECTOR MAY NOT SERVE AS A SURROGATE IN CARRYING OUT THE RESPONSIBILITIES OF

THE BUILDING OFFICIAL, ARCHITECT, OR ENGINEER OF RECORD.

B. THE PURPOSE OF THIS SPECIAL INSPECTION PLAN, AS REQUIRED BY THE FLORIDA BUILDING CODE 2014, SECTION 110 AND FLORIDA STATUTES CHAPTERS 471 AND 553, IS TO PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED DOCUMENTS.

A. THE SPECIAL INSPECTION SERVICES AS DESCRIBED HEREIN WILL BE RETAINED BY THE OWNER. THE CONTRACTOR SHALL BE FAMILIAR WITH THE SCOPE OF THE INSPECTIONS THAT WILL BE PERFORMED AND ALSO THE REQUIREMENTS OF THE CONTRACTOR AS DESCRIBED BELOW, PARTICULARLY REGARDING FORMWORK DESIGN AND INSPECTIONS. THE OWNER WILL PAY ALL COSTS OF EMPLOYING A SPECIAL INSPECTOR, BUT THE SPECIAL INSPECTOR SHALL BE

RESPONSIBLE TO THE ENFORCEMENT AGENCY.

GENERAL

PART VI - THRESHOLD INSPECTION

C. APPLICATION OF JOINT DETAILS AT EACH CONNECTION -- XX --

B. MEMBER LOCATIONS -- XX --

A. DETAILS SUCH AS BRACING AND STIFFENING -- XX --

6 INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS:

4. OTHER REINFORCING STEEL -- XX --

3. SHEAR REINFORCEMENT XX -- --

2. REINFORCING STEEL-RESISTING FLEXURAL AND AXIAL FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARY…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .