RIT PAK Techinical Requirements Document dated 3 July 25.pdf
PDF 357 KB Posted
- Attached to
- MSA G1 RIT PACK, Eglin AFB
- Solicitation number
- FA282325Q0058
About this file
This Technical Requirements Document (TRD) issued by the 96th Test Wing at Eglin Air Force Base details procurement specifications for MSA G1 Rapid Intervention Team (RIT) emergency air supply packs. The document outlines requirements for a specialized firefighter rescue equipment system, specifically seeking a RIT pack compatible with existing MSA G1 Self-Contained Breathing Apparatus (SCBA) systems. Key technical specifications include a 4,500 psi 60-minute carbon fiber high-pressure cylinder, Universal Air Connection (UAC), integrated regulator and low-pressure hose, luminescent pressure gauge, and a durable heat-resistant carrying system, with mandatory compliance to NFPA 1981/1982 standards.
The solicitation (FA282325Q0058) requires vendors to provide a comprehensive RIT pack system with user operation and maintenance training, with delivery mandated within 45 days after receipt of order to Fire Station 1 at Eglin AFB. Vendors must be registered in SAM, provide a CAGE code, and submit a clear, concise proposal demonstrating understanding of requirements by 1300 CT on 20 August 2025. The proposal must be electronically submitted to darren.alvarez.2@us.af.mil, strictly adhering to the provided CLIN pricing structure and including the attached Technical Requirements Document and Brand Name Justification.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combo RIT PACK.pdf | ||
| Combo RIT PACK.pdf | ||
| BNJ RIT Packs_Redacted dated 21 July 2025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 96TH TEST WING (AFMC)
EGLIN AIR FORCE BASE FLORIDA
3 July 2025
MEMORANDUM FOR: AFTC/PZ
FROM: 96 CES/CEF (Installation Fire Chief)
SUBJECT: Technical Requirements Document: MSA G1 Rapid Intervention Team (RIT) Packs Requirement Number: F1T2BR517A001
Purpose: To define the technical and operational requirements for the procurement of Rapid Intervention Team (RIT) emergency air supply packs compatible with the existing MSA G1 SCBA systems, enhancing firefighter rescue capabilities during mayday operations
Background: Our agency currently utilizes MSA G1 SCBA units as its standard air
Management system. The integration of a RIT pack fully compatible with this system ensures continuity in air supply equipment, eliminates interoperability issues, and enhances operational safety during firefighter rescue missions
Scope: This procurement covers: MSA G1 RIT Pack ExtendAire II system, associated hoses and high-pressure component carrying bag/harness system, compatible MSA G1 pressure-demand facepiece connection and training materials and warranty
Required Features: - SCBA Compatibility: Must be fully compatible with MSA G1 SCBA systems, including Universal Air Connection (UAC). -EBS- High-Pressure Cylinder: 4,500 psi, 60-minute carbon fiber cylinder. - Quick-Connect Capability: Universal air connection for rapid firefighter air replenishment. - Integrated Regulator and Low-Pressure Hose: Must include low-pressure facepiece and high-pressure cylinder hoses. - Pressure Gauge: Visual pressure indicator with luminescent markings or LED lighting. - Carrying System: Durable, heat- and flame-resistant bag with shoulder straps or handle. - NFPA Compliance: Must meet or exceed NFPA 1981 and NFPA 1982 (2023 Edition or most current).- Weight: Ideally under 25 lbs when fully assembled. - Serviceability: All parts must be user-serviceable or replaceable under standard maintenance protocols. - Warranty: Minimum 3-year warranty.
Support and Training Requirements: - Vendor must provide user operation and maintenance CBT training, must provide manuals and video training resources. - Local service availability is preferred for warranty or repair
Delivery: Lead time must not exceed 45 days After Receipt of Order. Must deliver to 1462 Wizard Way (Fire Station 1), Eglin AFB, Fl 32542
Standards Compliance: NFPA 1981/1982, NIOSH approves and OSHA compliant
MISSION-PEOPLE-PARTNERS
If you have any questions please contact me at 850-883-7157 or michael.clayton.8@us.af.mil.
MICHAEL G. CLAYTON, GS-14, USAF
Chief, Eglin Fire and Emergency Services mailto:michael.clayton.8@us.af.mil
| 2025-07-03T12:32:15-0500 | |
| CLAYTON.MICHAEL.G.1094793838 |
File details come from the government source that posted it. Updated .