This document is a technical drawing file for a Nutrition & Food Service and Eye/PT Clinic Addition project at the Louis A. Johnson VA Medical Center in Clarksburg, WV. The project is part of VA Contract No. 36C24521C0034 and involves mechanical system details, specifically focusing on walk-in cooler/freezer equipment and air handling units. The drawing includes technical specifications for condensing units, refrigerant lines, and alternate equipment configurations, with notations about equipment mounting, clearance requirements, and coordination with food service consultants.

Key technical details include specifications for air handling units AHU-36 and AHU-37, with alternate options for equipment removal or replacement. The document indicates the project is fully sprinklered and contains multiple submission stages from June 2021 to October 2022, with the most recent issue date of 10-21-2022. The drawing provides technical guidance for mechanical systems, including connection requirements for dissimilar metals, firestopping of pipe penetrations, and specific mounting instructions for refrigeration equipment.

View the file

Other files

File Type Posted
Drawing_Cooler and Connection Schedule.docx DOCX document
RFQ 36C24525Q0770.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. REFER TO SHEET AW601 FOR SIGNAGE SCHEDULES.

2. REFER TO SHEET AW611 AND AW612 FOR SIGNAGE TYES AND DETAILS.

3. FINAL SIGNAGE TYPE, DESIGN, CONTENT AND LOCATION TO BE APPROVED BY VA.

4. REFER TO SHEET AW601 FOR SIGNAGE MOUNTING HEIGHTS.

5. PROVIDE SIGNAGE AT GAS SHUT OFF VALVE.

FEC

CONSTRUCTION DOCUMENTS- ISSUED FOR BID 100% CD 2 SUBMISSION (RESUBMITTAL)

100% CD 2 SUBMISSION

75% CD1 SUBMISSION (RESUBMITTAL)

75% CD1 SUBMISSION

50% DD2 SUBMISSION

25% DD1 SUBMISSION

10-21-22 09-23-22 07-29-22 01-11-22 11-01-21 08-23-21 06-14-21

VA CONTRACT NO. 36C24521C0034

3300 Dundee Rd.

Northbrook, IL 60062 T: 847.952.9362 www. bancroft-ae.com BAE PROJECT NO. 20-109

STAMP

Office of Construction and Facilities Management U.S. Department of Veterans Affairs

Phase

FULLY SPRINKLERED

Project Title

NUTRITION & FOOD SERVICE AND

EYE/ PT CLINIC ADDITION

Location

1 MEDICAL CENTER DRIVE, CLARKSBURG, WV 26301

Issue Date Checked Drawn 10-21-2022

Project Number 540-370 Building Number Drawing Number

1. REFER TO SHEET AW601 FOR SIGNAGE SCHEDULES.

2. REFER TO SHEET AW611 AND AW612 FOR SIGNAGE TYES AND DETAILS.

3. FINAL SIGNAGE TYPE, DESIGN, CONTENT AND LOCATION TO BE APPROVED BY VA.

4. REFER TO SHEET AW601 FOR SIGNAGE MOUNTING HEIGHTS.

5. PROVIDE SIGNAGE AT GAS SHUT OFF VALVE.

CONSTRUCTION DOCUMENTS- ISSUED FOR BID10-21-22
100% CD 2 SUBMISSION (RESUBMITTAL)09-23-22
100% CD 2 SUBMISSION07-29-22
75% CD1 SUBMISSION (RESUBMITTAL)01-11-22
75% CD1 SUBMISSION11-01-21
50% DD2 SUBMISSION08-23-21
25% DD1 SUBMISSION06-14-21

NUTRITION & FOOD SERVICE AND

EYE/ PT CLINIC ADDITION

Location

1 MEDICAL CENTER DRIVE, CLARKSBURG, WV 26301

Issue Date Checked Drawn 10-21-2022

Project Number 540-370 Building Number Drawing Number

A. ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS OR COUPLINGS.

B. FIRESTOP ALL PIPE PENETRATIONS OF FIRE RATED WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS.

C. ALL STRAINERS SHALL BE PROVIDED WITH HOSE-BIB CONNECTIONS.

X

1 7A1 1.

CONDENSING UNIT FOR WALK-IN COOLERS/FREEZERS TO BE PROVIDED BY FOOD SERVICE CONSULTANT. SHOWN HERE FOR COORDINATION PURPOSES ONLY. REFER TO KITCHEN EQUIPMENT PLANS FOR FURTHER INFORMATION.

2. REFRIGERANT LIQUID/SUCTION LINES DOWN TO FIRST FLOOR. SIZE PIPING PER MANUFACTURER'S RECOMMENDATIONS.

3. CONDENSING UNIT MOUNTING PAD.

4. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCE REQUIREMENTS.

5. EXISTING CONDENSING UNIT TO REMAIN.

1 6C

EF-2000

EF-B3

AHU-37

97 LBS/HR MPS

21.3 GPM CHW

3/4" COND DN TO ROOF

1" MPS DN

3/4" MPR DN

2" CHWS/R DN

1-1 /4" COND DN TO ROOF

AHU-36

1356 LBS/HR MPS

148.5 GPM CHW

3" CHWS/R DN

1 7A2

3" MPS DN 3 4

1-1/2" MPR DN

ALTERNATES

ACCU-1124NN 2

2 TONS

BASE BID: AS SHOWN.

REFER TO SPECIFICATION SECTION 01 00 00 AND SHEETS GI004 AND GI004A FOR FURTHER INFORMATION ON DEDUCT ALTERNATES.

ALTERNATE NO. 2: REMOVE AHU-37 FROM SCOPE OF WORK. PHYSICAL THERAPY CLINIC TO BE SERVED BY ACSS-46 IN MECHANICAL ROOM 2128.

CONSTRUCTION DOCUMENTS- ISSUED FOR BID10-21-22
100% CD 2 SUBMISSION (RESUBMITTAL)09-23-22
100% CD 2 SUBMISSION07-29-22
75% CD1 SUBMISSION (RESUBMITTAL)01-11-22
75% CD1 SUBMISSION11-01-21
50% DD2 SUBMISSION08-23-21
25% DD1 SUBMISSION06-14-21

NUTRITION & FOOD SERVICE AND

EYE/ PT CLINIC ADDITION

Location

1 MEDICAL CENTER DRIVE, CLARKSBURG, WV 26301

Issue Date Checked Drawn 10-21-2022

Project Number 540-370 Building Number Drawing Number image6.png image7.png image8.png image9.png image10.png image11.png image12.png image13.png image14.png image15.png image16.png image17.png image18.png image19.png image20.png image21.png image22.png image23.png image24.png image25.png image26.png image27.png image28.png image29.png image30.png image31.png image32.png image33.png image34.png image35.png image36.png image37.png image38.png image39.png image40.png image41.png image42.png image43.png image44.png image45.png image1.png image46.png image47.png image48.png image49.png image50.png image51.png image52.png image53.png image54.png image55.png image2.png image56.png image57.png image58.png image59.png image60.png image61.png image62.png image63.png image64.png image65.png image3.png image66.png image67.png image68.png image69.png image70.png image71.png image72.png image73.png image74.png image4.png image75.png image76.png image77.png image78.png image5.png

File details come from the government source that posted it. Updated .