SPECIFICATIONS
PROJECT BI20BF202H6
WOMEN’S CLINIC RENOVATION
BLACKFEET COMMUNITY HOSPITAL
BROWNING, MONTANA
NOVEMBER, 2020
BILLINGS AREA INDIAN HEALTH SERVICE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Women’s Clinic Renovation SPECIFICATIONS Blackfeet Community Hospital
Table of Contents
CONTENTS
SECTION 011000 - SUMMARY 1
SECTION 013300 - SUBMITTAL PROCEDURES 2
SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 5
SECTION 054000 - COLD-FORMED METAL FRAMING 6
SECTION 081416 - FLUSH WOOD DOORS 8
SECTION 085200 - WOOD WINDOWS 10
SECTION 087111 - DOOR HARDWARE 12
SECTION 092900 - GYPSUM BOARD 15
SECTION 099123 - INTERIOR PAINTING 17
SECTION 123216 - MANUFACTURED PLASTIC-LAMINATE-CLAD CASEWORK 19
SECTION 123623.13 - PLASTIC-LAMINATE-CLAD COUNTERTOPS 21
SECTION 224216.13 - COMMERCIAL LAVATORIES 23
SECTION 233713.23 - LOUVERS 25
SECTION 260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 26
SECTION 265116 - FLUORESCENT INTERIOR LIGHTING 28
SECTION 271513 - COMMUNICATIONS COPPER HORIZONTAL CABLING 31
Section 011000 - Summary Page 1
SECTION 011000 - SUMMARY
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Project information.
2. Work covered by Contract Documents.
3. Contractor's use of site and premises.
4. Coordination with occupants.
5. Work restrictions.
1.2 PROJECT INFORMATION
A. Project Identification: Women’s Clinic Renovation.
B. Project Location: Blackfeet Community Hospital, Browning, Montana
1.3 WORK COVERED BY CONTRACT DOCUMENTS
A. The Work of Project is defined by the Contract Documents and consists of replacement of existing reception area, installation of new nursing station, installation of new office partition and doors, renovation of existing exterior door hardware, and renovation of existing examination rooms.
B. Type of Contract: Single prime contract.
C. Restricted Use of Site: Contractor shall have limited use of Project site for construction operations as indicated on Drawings by the Contract limits and as indicated by requirements of this Section.
D. Limits on Use of Site: Limit use of Project site to Work in areas indicated. Do not disturb portions of Project site beyond areas in which the Work is indicated.
E. Condition of Existing Building: Maintain portions of existing building affected by construction operations in a weathertight condition throughout construction period. Repair damage caused by construction operations.
1.4 COORDINATION WITH OCCUPANTS
A. Full Owner Occupancy: Owner will occupy site and existing building(s) during entire construction period.
Cooperate with Owner during construction operations to minimize conflicts and facilitate Owner usage.
Perform the Work so as not to interfere with Owner's day-to-day operations. Maintain existing exits unless otherwise indicated.
1.5 WORK RESTRICTIONS
A. On-Site Work Hours: Limit work in the existing building to normal business working hours of 8:00 a.m. to 5:00 p.m., Monday through Friday, unless otherwise indicated.
B. Existing Utility Interruptions: Do not interrupt utilities serving facilities occupied by Owner or others unless permitted under the following conditions and then only after providing temporary utility services according to requirements indicated:
1. Notify Facility Manager not less than two days in advance of proposed utility interruptions.
2. Obtain Facility Manager's written permission before proceeding with utility interruptions.
C. Noise, Vibration, Dust, and Odors: Coordinate operations that may result in high levels of noise and vibration, dust, odors, or other disruption to Owner occupancy with Owner.
END OF SECTION 011000
Section 013300 – Submittal Procedures Page 2
SECTION 013300 - SUBMITTAL PROCEDURES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Submittal schedule requirements.
2. Administrative and procedural requirements for submittals.
1.2 DEFINITIONS
A. Action Submittals: Written and graphic information and physical samples that require Engineer's responsive action. Action submittals are those submittals indicated in individual Specification Sections as "action submittals."
B. Informational Submittals: Written and graphic information and physical samples that do not require Engineer's responsive action. Submittals may be rejected for not complying with requirements.
Informational submittals are those submittals indicated in individual Specification Sections as "informational submittals."
1.3 SUBMITTAL SCHEDULE
A. Submittal Schedule: Submit, as an action submittal, a list of submittals, arranged in chronological order by dates required by construction schedule.
1.4 SUBMITTAL FORMATS
A. Submittal Information: Include the following information in each submittal:
1. Project name.
2. Date.
3. Name of firm or entity that prepared submittal.
4. Number and title of Specification Section.
5. Drawing number and detail references, as appropriate.
6. Indication of full or partial submittal.
7. Provide a space on or beside title block to record Contractor’s review and Engineer’s acton.
8. Other necessary identification.
B. Contractor has the option of providing paper or electronic submittals. Electronic submittals shall be in pdf format.
1.5 SUBMITTAL PROCEDURES
A. Prepare and submit submittals required by individual Specification Sections.
B. Coordination: Coordinate preparation and processing of submittals with performance of construction activities.
C. Processing Time: Allow time for submittal review, including time for resubmittals, as follows. Time for review shall commence on Engineer’s receipt of submittal. No extension of the Contract Time will be authorized because of failure to transmit submittals enough in advance of the Work to permit processing, including resubmittals. Allow 10 days for initial review of each submittal and 5 days for review of each resubmittal. Allow additional time if coordination with subsequent submittals is required.
D. Resubmittals: Make resubmittals in same form and number of copies as initial submittal.
1.6 SUBMITTAL REQUIREMENTS
A. Product Data: Collect information into a single submittal for each element of construction and type of product or equipment.
Section 013300 – Submittal Procedures Page 3
1. If information must be specially prepared for submittal because standard published data are unsuitable for use, submit as Shop Drawings, not as Product Data.
2. Mark each copy of each submittal to show which products and options are applicable.
3. Include the following information, as applicable:
a. Manufacturer's catalog cuts.
b. Manufacturer's product specifications.
c. Standard color charts.
d. Statement of compliance with specified referenced standards.
e. Notation of coordination requirements.
f. Availability and delivery time information.
4. For equipment, include the following in addition to the above, as applicable:
a. Wiring diagrams that show factory-installed wiring.
b. Printed performance curves.
c. Operational range diagrams.
d. Clearances required to other construction, if not indicated on accompanying Shop Drawings.
5. Submit Product Data before Shop Drawings, and before or concurrent with Samples.
B. Shop Drawings: Prepare Project-specific information, drawn accurately to scale. Do not base Shop Drawings on reproductions of the Contract Documents or standard printed data. Include the following information, as applicable:
1. Identification of products.
2. Schedules.
3. Compliance with specified standards.
4. Notation of coordination requirements.
5. Notation of dimensions established by field measurement.
6. Relationship and attachment to adjoining construction clearly indicated.
7. Seal and signature of professional engineer if specified.
C. Samples: Submit Samples for review of kind, color, pattern, and texture for a check of these characteristics with other materials.
1. Identification: Permanently attach label on unexposed side of Samples that includes the following:
a. Project name and submittal number.
b. Generic description of Sample.
c. Product name and name of manufacturer.
d. Sample source.
e. Number and title of applicable Specification Section.
f. Specification paragraph number and generic name of each item.
D. Product Schedule: Prepare a written summary indicating types of products required for the Work and their intended location.
E. Qualification Data: Prepare written information that demonstrates capabilities and experience of firm or person. Include lists of completed projects with project names and addresses, contact information of Engineers and owners, and other information specified.
1.7 CONTRACTOR'S REVIEW
A. Action Submittals and Informational Submittals: Review each submittal and check for coordination with other Work of the Contract and for compliance with the Contract Documents. Note corrections and field dimensions. Mark with approval stamp before submitting to Engineer.
B. Contractor's Approval: Indicate Contractor's approval for each submittal with a uniform approval stamp.
Include name of reviewer, date of Contractor's approval, and statement certifying that submittal has been reviewed, checked, and approved for compliance with the Contract Documents.
Section 013300 – Submittal Procedures Page 4
1.8 ENGINEER'S REVIEW
A. Action Submittals: Engineer will review each submittal, indicate corrections or revisions required, and return it.
B. Informational Submittals: Engineer will review each submittal and will return it if it does not comply with requirements. Engineer will forward each submittal to appropriate party.
C. Partial submittals prepared for a portion of the Work will be reviewed when use of partial submittals has received prior approval from Engineer.
D. Incomplete submittals are unacceptable, will be considered nonresponsive, and will be returned for resubmittal without review.
E. Submittals not required by the Contract Documents will be returned by Engineer without action.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION (Not Used)
END OF SECTION 013300
Section 017419 - Construction Waste Management and Disposal Page 5
SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes requirements for disposing of demolition and construction waste.
PART 2 - PRODUCTS (NOT USED)
PART 3 - EXECUTION
3.1 DISPOSAL OF WASTE
A. General: Except for items or materials to be salvaged or recycled, remove waste materials from Project site and legally dispose of them in a landfill or incinerator acceptable to authorities having jurisdiction.
1. Except as otherwise specified, do not allow waste materials that are to be disposed of accumulate on-site.
2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas.
B. General: Except for items or materials to be salvaged or recycled, remove waste materials and legally dispose of at designated spoil areas on Owner’s property.
C. Burning: Do not burn waste materials.
END OF SECTION 017419
Section 054000 – Cold Formed Steel Framing Page 6
SECTION 054000 - COLD-FORMED METAL FRAMING
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes interior non-load bearing wall framing.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Cold-Formed Steel Framing Standards: Unless more stringent requirements are indicated, framing shall comply with AISI S100, AISI S200, and the following:
1. Wall Studs: AISI S211.
2. Headers: AISI S212.
3. Lateral Design: AISI S213.
2.2 COLD-FORMED STEEL FRAMING MATERIALS
A. Steel Sheet: ASTM A1003/A1003M, Structural Grade, Type H, metallic coated.
B. Steel Sheet for Clips: ASTM A653/A653M, structural steel, zinc coated.
2.3 INTERIOR NON-LOAD-BEARING WALL FRAMING
A. Steel Studs: Manufacturer's standard C-shaped steel studs.
B. Steel Track: Manufacturer's standard U-shaped steel track, of web depths indicated, unpunched, with unstiffened flanges, and matching minimum base-metal thickness of steel studs.
C. Vertical Deflection Clips: Manufacturer's standard clips, capable of accommodating upward and downward vertical displacement of primary structure through positive mechanical attachment to stud web.
2.4 FRAMING ACCESSORIES
A. Fabricate steel-framing accessories from ASTM A1003/A1003M, Structural Grade, Type H, metallic coated steel sheet, of same grade and coating designation used for framing members.
B. Provide accessories of manufacturer's standard thickness and configuration, unless otherwise indicated.
2.5 ANCHORS, CLIPS, AND FASTENERS
A. Steel Shapes and Clips: ASTM A36/A36M, zinc coated by hot-dip process according to
ASTM A123/A123M.
B. Post-Installed Anchors: Fastener systems with bolts of same basic metal as fastened metal, if visible, unless otherwise indicated; with working capacity greater than or equal to the design load, according to an evaluation report acceptable to authorities having jurisdiction.
C. Power-Actuated Anchors: Fastener systems with working capacity greater than or equal to the design load, according to an evaluation report acceptable to authorities having jurisdiction, based on ICC-ES AC70.
D. Mechanical Fasteners: ASTM C1513, corrosion-resistant-coated, self-drilling, self-tapping, steel drill screws.
2.6 MISCELLANEOUS MATERIALS
A. Galvanizing Repair Paint: ASTM A780/A780M.
B. Shims: Load-bearing, high-density, multimonomer, nonleaching plastic; or cold-formed steel of same grade and metallic coating as framing members supported by shims.
C. Sill Sealer Gasket: Closed-cell neoprene foam, 1/4 inch thick, selected from manufacturer's standard widths to match width of bottom track or rim track members as required.
Section 054000 – Cold Formed Steel Framing Page 7
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Cold-formed steel framing may be shop or field fabricated for installation, or it may be field assembled.
B. Install cold-formed steel framing according to AISI S200, AISI S202, and manufacturer's written instructions unless more stringent requirements are indicated.
C. Install cold-formed steel framing and accessories plumb, square, and true to line, and with connections securely fastened.
D. Install temporary bracing and supports to secure framing and support loads equal to those for which structure was designed. Maintain braces and supports in place, undisturbed, until entire integrated supporting structure has been completed and permanent connections to framing are secured.
E. Do not bridge building expansion joints with cold-formed steel framing. Independently frame both sides of joints.
F. Fasten hole-reinforcing plate over web penetrations that exceed size of manufacturer's approved or standard punched openings.
3.2 INSTALLATION OF INTERIOR NON-LOAD-BEARING WALL FRAMING
A. Install continuous tracks sized to match studs. Align tracks accurately and securely anchor to supporting structure.
B. Fasten both flanges of studs to top and bottom track unless otherwise indicated. Space studs 16 inches.
C. Set studs plumb, except as needed for diagonal bracing or required for nonplumb walls or warped surfaces and similar requirements.
D. Isolate non-load-bearing steel framing from building structure to prevent transfer of vertical loads while providing lateral support.
E. Install horizontal bridging in wall studs, spaced vertically in rows indicated on Shop Drawings but not more than 48 inches apart. Fasten at each stud intersection.
F. Install miscellaneous framing and connections, including stud kickers, web stiffeners, clip angles, continuous angles, anchors, and fasteners, to provide a complete and stable wall-framing system.
3.3 INSTALLATION TOLERANCES
A. Install cold-formed steel framing level, plumb, and true to line to a maximum allowable tolerance variation of 1/8 inch in 10 feet.
3.4 REPAIRS
A. Galvanizing Repairs: Prepare and repair damaged galvanized coatings on fabricated and installed cold-formed steel framing with galvanized repair paint according to ASTM A780/A780M and manufacturer's written instructions.
END OF SECTION 054000
Section 081416 – Flush Wood Doors Page 8
SECTION 081416 - FLUSH WOOD DOORS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes:
1. Five-ply flush wood veneer-faced doors for transparent finish.
1.2 ACTION SUBMITTALS
A. Product Data: For each door provided.
PART 2 - PRODUCTS
2.1 DOOR CONSTRUCTION, GENERAL
A. Finish: Transparent.
B. Face: Red Oak, plain sliced.
C. Match between veneer leaves: Random.
D. Match between door faces: Running.
E. Stiles: Same species as face, or a compatible species.
2.2 SOLID-CORE, FIVE-PLY FLUSH WOOD VENEER-FACED DOORS
A. Interior Doors:
1. Performance Grade: ANSI/WDMA I.S. 1A Standard Duty.
2. Faces: Single-ply wood veneer not less than 1/50 inch thick. Red Oak species.
3. Core for Non-Fire-Rated Doors: ANSI A208.1
4. Construction: Five plies, bonded to core.
B. Fire-rated doors: Construction and core specified above for type of indicated or manufacturer’s standard mineral core construction as required to provide fire rating indicated.
2.3 LIGHT FRAMES AND LOUVERS
A. Wood Beads for Light Openings in Wood Doors: Provide manufacturer’s standard wood beads.
B. Metal Louvers: Hot-dip galvanized steel, 0.040 inch thick, with baked enamel or powder coated finish.
2.4 FABRICATION
A. Factory fit doors to suit frame-opening sizes indicated.
B. Factory machine doors for hardware that is not surface applied.
C. Louvers: Factory install louvers in prepared openings.
2.5 FINISHING
A. Finish wood doors at factory.
B. Finish:
1. Transparent Finish.
2. Premium Grade.
3. Staining: None.
4. Effect: Open-grain finish.
5. Sheet: Satin.
Section 081416 – Flush Wood Doors Page 9
3.1 INSTALLATION
A. Hardware: For installation, see Section 087100 "Door Hardware."
B. Install doors and frames to comply with manufacturer's written instructions and referenced quality standard, and as indicated.
C. Install frames level, plumb, true, and straight.
D. Job-Fitted Doors:
1. Align and fit doors in frames with uniform clearances and bevels.
2. Machine doors for hardware.
3. Seal edges of doors, edges of cutouts, and mortises after fitting and machining.
4. Clearances:
a. Provide 1/8 inch at heads, jambs, and between pairs of doors.
b. Provide 1/8 inch from bottom of door to top of decorative floor finish or covering unless otherwise indicated on Drawings.
c. Where threshold is shown or scheduled, provide1/4 inch from bottom of door to top of threshold unless otherwise indicated.
d. Comply with NFPA 80 for fire-rated doors.
5. Bevel non-fire-rated doors 1/8 inch in 2 inches at lock and hinge edges.
E. Factory-Fitted Doors: Align in frames for uniform clearance at each edge.
F. Factory-Finished Doors: Restore finish before installation if fitting or machining is required at Project site.
3.2 ADJUSTING
A. Operation: Rehang or replace doors that do not swing or operate freely.
B. Finished Doors: Replace doors that are damaged or that do not comply with requirements. Doors may be repaired or refinished if Work complies with requirements and shows no evidence of repair or refinishing.
END OF SECTION 081416
Section 085200 – Wood Windows Page 10
SECTION 085200 - WOOD WINDOWS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes vinyl-clad wood windows.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Include plans, elevations, sections, hardware, accessories, insect screens, operational clearances, and details of installation, including anchor, flashing, and sealant installation.
C. Samples: For each exposed product and for each color specified.
1.3 WARRANTY
A. Manufacturer's Warranty: Manufacturer agrees to repair or replace wood windows that fail in materials or workmanship within specified warranty period.
PART 2 - PRODUCTS
2.1 WINDOW PERFORMANCE REQUIREMENTS
A. Product Standard: Comply with AAMA/WDMA/CSA 101/I.S.2/A440 for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated.
2.2 WOOD WINDOWS
A. Frames and Sashes: Fine-grained wood lumber complying with AAMA/WDMA/CSA 101/I.S.2/A440; kiln dried to a moisture content of not more than 12 percent at time of fabrication; free of visible finger joints, blue stain, knots, pitch pockets, and surface checks larger than 1/32 inch deep by 2 inches wide; water-repellent preservative treated.
B. Glass: Clear annealed glass, ASTM C1036, Type 1, Class 1, q3.
C. Glazing System: Manufacturer's standard factory-glazing system that produces weathertight seal.
D. Hardware, General: Provide manufacturer's standard corrosion-resistant hardware sized to accommodate sash weight and dimensions.
E. Horizontal-Sliding Window Hardware:
1. Sill Cap/Track: Designed to comply with performance requirements indicated.
2. Locks and Latches: Operated from the inside only.
3. Roller Assemblies: Low-friction design.
2.3 FABRICATION
A. Fabricate wood windows in sizes indicated. Include a complete system for installing and anchoring windows.
B. Glaze wood windows in the factory.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Comply with manufacturer's written instructions for installing windows, hardware, accessories, and other components. For installation procedures and requirements not addressed in manufacturer's written instructions, comply with installation requirements in ASTM E2112.
Section 085200 – Wood Windows Page 11
B. Install windows level, plumb, square, true to line, without distortion, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction to produce weathertight construction.
C. Adjust operating sashes and hardware for a tight fit at contact points and weather stripping for smooth operation and weathertight closure.
D. Clean exposed surfaces immediately after installing windows. Remove excess sealants, glazing materials, dirt, and other substances.
E. Remove and replace sashes if glass has been broken, chipped, cracked, abraded, or damaged during construction period.
END OF SECTION 085200
Section 085200 – Wood Windows Page 12
SECTION 087111 - DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes mechanical door hardware for swinging doors.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.3 CLOSEOUT SUBMITTALS
A. Maintenance data.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Means of Egress Doors: Latches do not require more than 15 lbf to release the latch. Locks do not require use of a key, tool, or special knowledge for operation.
B. Accessibility Requirements: For door hardware on doors in an accessible route, comply with the DOJ's "2010 ADA Standards for Accessible Design".
2.2 HINGES
A. Hinges: BHMA A156.1.
B. Mounting: Full mortise.
C. Size: 4 ½” x 4 ½”.
D. Material: Polished and plated steel, .134 gauge.
E. Non-removable pin.
2.3 LOCKSETS
A. General
1. Solid cast levers.
2. Anti-rotation throughbolts.
3. ANSI Grade 1.
4. Lock chassis: Steel, zinc dichromated for corrosion resistance.
5. Latchbolt: Brass, chrome plated ½” throw.
6. Strike: Wrought brass or bronze, ANSI curved lip standard.
7. Cylinder: Brass, 6 pin, L4 keyway, 0-bitted standard.
8. Lever: Die cast zinc, 5” .
9. Rose: Wrought brass or bronze, 3 ½” diameter.
10. Finish: Bright chromium plated.
11. Reference product: Corbin Russwin CL3300 Series, NZD.
B. Lockset group 1:
1. Type: Classroom.
2. ANSI Series 4000 F84.
3. Deadlocking latchbolt inside.
4. Outside lever locked by key outside.
5. Inside lever always free.
6. Reference product: Corbin Russwin CL3355.
C. Lockset group 2:
Section 085200 – Wood Windows Page 13
1. Type: Entrance or Office.
2. ANSI Series 4000 F81/F82.
3. Deadlocking latchbolt inside.
4. Outside lever locked by key outside.
5. Inside lever always free.
6. Reference product: Corbin Russwin CL3351.
2.4 DOORSTOPS
A. Description: Concave wall door stop with plastic drywall anchor.
B. Polished wrought brass, bronze, or aluminum finich.
C. Concave rubber allows know to strike stop without damaging or engaging lock template.
D. Size: Approximately 2 ½” diameter.
2.5 CLOSERS
A. Surface type door closers shall be fully hydraulic, full rack and pinion action with cast iron case.
B. Separate adjusting valves shall be provided for closing speed and backcheck.
2.6 SMOKE GASKETING
A. Extruded from high grade silicone.
B. Seals begin compressing at ¼”.
C. Air infiltration tested per ASTM E 283-1984 or most recent edition.
2.7 KEYING
A. Master key locks to Owner’s existing system.
B. Keys: Nickel silver.
2.8 KICKPLATES
A. Material: Brass, bronze, or stainless steel as appropriate for required finish.
B. Kick plates shall be 10” high and 3” narrower than door.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations.
1. Wood Doors: DHI's "Recommended Locations for Architectural Hardware for Wood Flush Doors."
B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work. Do not install surface-mounted items until finishes have been completed on substrates involved.
C. Hinges: Install types and in quantities indicated in door hardware schedule, but not fewer than the number recommended by manufacturer for application indicated or one hinge for every 30 inches of door height, whichever is more stringent, unless other equivalent means of support for door, such as spring hinges or pivots, are provided.
D. Stops: Provide floor stops for doors unless wall or other type stops are indicated in door hardware schedule.
Do not mount floor stops where they will impede traffic.
E. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.
3.2 ADJUSTING
A. Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to
Section 085200 – Wood Windows Page 14 compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
3.3 HARDWARE SCHEDULE
A. Hardware set 1:
1. Lockset 2.
2. Hinges: 3.
3. Doorstop.
4. Kickplate.
5. Closer.
6. Smoke Gasket.
B. Hardware set 2:
1. Lockset 1.
2. Hinges: 3.
3. Doorstop.
4. Kickplate.
C. Hardware set 3:
1. Lockset 1.
2. Hinges: 4.
3. Doorstop.
4. Kickplate.
END OF SECTION 087111
Section 092900 – Gypsum Board Page 15
SECTION 092900 - GYPSUM BOARD
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Interior gypsum board.
2. Texture finishes.
1.2 ACTION SUBMITTALS
A. Product Data: For each gypsum board type.
PART 2 - PRODUCTS
2.1 GYPSUM BOARD, GENERAL
A. Size: Provide maximum lengths and widths available that will minimize joints in each area and that correspond with support system indicated.
B. Provide ASTM C1396 board, unless otherwise noted.
C. Provide wallboard type and thickness as noted on drawings.
2.2 TRIM ACCESSORIES
A. Interior Trim: ASTM C1047, Galvanized or aluminum-coated steel sheet, rolled zinc, plastic, or paper-faced galvanized-steel sheet
2.3 JOINT TREATMENT MATERIALS
A. General: Comply with ASTM C475/C475M.
B. Joint Tape:
1. Interior Gypsum Board: Paper.
C. Joint Compound for Interior Gypsum Board: For each coat, use formulation that is compatible with other compounds applied on previous or for successive coats.
2.4 AUXILIARY MATERIALS
A. Provide auxiliary materials that comply with referenced installation standards and manufacturer's written instructions.
B. Steel Drill Screws: ASTM C1002 unless otherwise indicated.
1. Use screws complying with ASTM C954 for fastening panels to steel members from 0.033 to 0.112 inch thick.
2. For fastening cementitious backer units, use screws of type and size recommended by panel manufacturer.
2.5 TEXTURE FINISHES
A. Primer: As recommended by textured finish manufacturer.
B. Polystyrene Aggregate Ceiling Finish: Water-based, job-mixed, polystyrene aggregate finish with flame-spread and smoke-developed indexes of not more than 25 when tested according to ASTM E84.
C. Aggregate Finish: Water-based, job-mixed, aggregated, drying-type texture finish for spray application.
D. Non-Aggregate Finish: Premixed, vinyl texture finish for spray application.
Section 092900 – Gypsum Board Page 16
3.1 INSTALLATION AND FINISHING OF PANELS
A. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold damaged.
B. Comply with ASTM C840.
C. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments. Provide
1/4- to 1/2-inch-wide spaces at these locations and trim edges with edge trim where edges of panels are exposed. Seal joints between edges and abutting structural surfaces with acoustical sealant.
D. For trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels.
Otherwise, attach trim according to manufacturer's written instructions.
E. Prefill open joints, rounded or beveled edges, and damaged surface areas.
F. Apply joint tape over gypsum board joints, except for trim products specifically indicated as not intended to receive tape.
G. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C840:
1. Level 1: Ceiling plenum areas, concealed areas, and where indicated.
2. Level 2: Panels that are substrate for tile or acoustical finish..
3. Level 3: Where indicated on Drawings.
4. Level 4: At panel surfaces that will be exposed to view unless otherwise indicated.
3.2 APPLYING TEXTURE FINISHES
A. Surface Preparation and Primer: Prepare and apply primer to gypsum panels and other surfaces receiving texture finishes. Apply primer to surfaces that are clean, dry, and smooth.
B. Texture Finish Application: Mix and apply finish using powered spray equipment, to produce a uniform texture free of starved spots or other evidence of thin application or of application patterns.
3.3 PROTECTION
A. Protect installed products from damage from weather, condensation, direct sunlight, construction, and other causes during remainder of the construction period.
B. Remove and replace panels that are wet, moisture damaged, and mold damaged.
END OF SECTION 092900
Section 099123 - Interior Painting Page 17
SECTION 099123 - INTERIOR PAINTING
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes surface preparation and the application of paint systems on interior substrates.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product. Include preparation requirements and application instructions.
B. Samples: For each type of paint system and in each color and gloss of topcoat.
PART 2 - PRODUCTS
2.1 PAINT, GENERAL
A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."
B. Material Compatibility:
1. Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.
2. For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.
C. Colors: As selected by Engineer from manufacturer's full range.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions, with Applicator present, for compliance with requirements for conditions affecting performance of the Work.
B. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers.
C. Proceed with coating application only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual" applicable to substrates and paint systems indicated.
B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting. After completing painting operations, reinstall items that were removed. Remove surface-applied protection if any.
3.3 APPLICATION
A. Apply paints according to manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual."
B. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.
3.4 INTERIOR PAINTING SCHEDULE
A. Wood Substrates: Wood trim windows.
Section 099123 - Interior Painting Page 18
1. Latex over Latex Primer System:
a. Prime Coat: Primer, latex, for interior wood.
b. Topcoat: Latex, interior, gloss.
B. Wood Substrates: Wood paneling and casework.
1. Latex over Latex Primer System:
a. Prime Coat: Primer, latex, for interior wood.
b. Topcoat: Latex, interior, semi-gloss.
C. Gypsum Board and Plaster Substrates:
1. Latex over Latex Sealer System:
a. Prime Coat: Latex, interior, matching topcoat.
b. Topcoat: Latex, interior, semi-gloss.
END OF SECTION 099123
Section 123216 - Manufactured Plastic-Laminate-Clad Casework Page 19
SECTION 123216 - MANUFACTURED PLASTIC-LAMINATE-CLAD CASEWORK
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Plastic-laminate-clad casework.
2. Casework hardware and accessories.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For plastic-laminate-clad casework.
C. Samples: For casework and hardware finishes.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: An authorized representative who is trained and approved by manufacturer.
1.4 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of casework that fail in materials or workmanship within specified warranty period.
1. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 GENERAL REQUIREMENTS FOR CASEWORK
A. Quality Standard: Unless otherwise indicated, comply with the AWI/AWMAC/WI's "Architectural Woodwork Standards" for grades of casework indicated for construction, finishes, installation, and other requirements.
B. Product Designations: Drawings indicate sizes, configurations, and finish materials of manufactured plastic-laminate-clad casework by referencing designated manufacturer's catalog numbers. Other manufacturers' casework of similar sizes and door and drawer configurations, of same finish materials, and complying with the Specifications may be considered.
2.2 MATERIALS
A. Maximum Moisture Content for Lumber: 7 percent for hardwood and 12 percent for softwood.
B. Hardwood Plywood: HPVA HP-1, particleboard core except where veneer core is indicated.
C. Softwood Plywood: DOC PS 1.
D. Particleboard: ANSI A208.1, Grade M-2.
E. MDF: Medium-density fiberboard, ANSI A208.2,.
F. Hardboard: ANSI A135.4, Class 1 tempered.
G. Plastic Laminate: High-pressure decorative laminate complying with NEMA LD 3.
H. PVC Edgebanding for Plastic Laminate: Rigid PVC extrusions, through color with satin finish, 3.0 mm thick at doors and drawer fronts, 1.0 mm thick elsewhere.
I. Glass for Glazed Doors: Clear float glass complying with ASTM C1036, Type I, Class 1, Quality-Q3; not less than 3.0 mm thick.
2.3 CASEWORK HARDWARE AND ACCESSORIES
A. Hardware, General: Unless otherwise indicated, provide manufacturer's standard commercial-quality, heavy-duty hardware.
Section 123216 - Manufactured Plastic-Laminate-Clad Casework Page 20
3.1 INSTALLATION
A. Grade: Install casework to comply with same quality standard grade as item to be installed.
B. Install casework level, plumb, and true in line; shim as required using concealed shims. Where casework abuts other finished work, apply filler strips and scribe for accurate fit, with fasteners concealed where practical.
C. Base Cabinets: Set cabinets straight, level, and plumb. Adjust subtops within 1/16 inch of a single plane.
Align similar adjoining doors and drawers to a tolerance of 1/16 inch. Bolt adjacent cabinets together with joints flush, tight, and uniform.
D. Wall Cabinets: Hang cabinets straight, level, and plumb. Adjust fronts and bottoms within 1/16 inch of a single plane. Fasten cabinets to hanging strips, masonry, framing, wood blocking, or reinforcements in walls and partitions. Align similar adjoining doors to a tolerance of 1/16 inch.
E. Fasten casework to adjacent units and to masonry, framing, wood blocking, or reinforcements in walls and partitions to comply with the AWI/AWMAC/WI's "Architectural Woodwork Standards."
F. Install hardware uniformly and precisely. Set hinges snug and flat in mortises unless otherwise indicated.
Adjust and align hardware so moving parts operate freely and contact points meet accurately. Allow for final adjustment after installation.
G. Adjust operating hardware so doors and drawers operate smoothly without warp or bind. Lubricate operating hardware as recommended by manufacturer.
H. Clean finished surfaces, touch up as required, and remove or refinish damaged or soiled areas to match original factory finish, as approved by Engineer.
END OF SECTION 123216
Section 123623.13 - Plastic-Laminate-Clad Countertops Page 21
SECTION 123623.13 - PLASTIC-LAMINATE-CLAD COUNTERTOPS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Plastic-laminate-clad countertops.
1.2 INFORMATIONAL SUBMITTALS
A. Product Certificates: For the following:
1. Composite wood products.
2. High-pressure decorative laminate.
3. Adhesives.
B. Quality Standard Compliance Certificates: [AWI Quality Certification Program] [WI Certified Compliance Program].
PART 2 - PRODUCTS
2.1 PLASTIC-LAMINATE-CLAD COUNTERTOPS
A. Quality Standard: Unless otherwise indicated, comply with the "Architectural Woodwork Standards" for grades of plastic-laminate-clad countertops indicated for construction, finishes, installation, and other requirements.
B. High-Pressure Decorative Laminate: NEMA LD 3, Grade HGS.
C. Colors, Patterns, and Finishes: Provide materials and products that result in colors and textures of exposed laminate surfaces as selected by Engineer from manufacturer’s full range.
D. Edge Treatment: Same as laminate cladding on horizontal surfaces.
E. Core Material: Particleboard or MDF.
F. Core Material at Sinks: Particleboard made with exterior glue MDF made with exterior glue or exterior-grade plywood.
G. Core Thickness: 1-1/8 inch.
2.2 WOOD MATERIALS
A. Wood Products: Provide materials that comply with requirements of referenced quality standard unless otherwise indicated.
1. Wood Moisture Content: 5 to 10 percent.
B. Composite Wood Products: Provide materials that comply with requirements of referenced quality standard for each type of countertop and quality grade specified unless otherwise indicated.
1. MDF: Medium-density fiberboard, ANSI A208.2,
2. Particleboard: ANSI A208.1,.
3. Softwood Plywood: DOC PS 1.
2.3 ACCESSORIES
A. Wire-Management Grommets: Circular, molded-plastic grommets and matching plastic caps with slot for wire passage.
B. Paper Slots: 12 inches long by 1-3/4 inches wide by 1 inch deep; molded-plastic, paper-slot liner with 1/4-inch lip.
Section 123623.13 - Plastic-Laminate-Clad Countertops Page 22
2.4 MISCELLANEOUS MATERIALS
A. Adhesive for Bonding Plastic Laminate: As selected by fabricator to comply with requirements.
2.5 FABRICATION
A. Fabricate countertops to dimensions, profiles, and details indicated. Provide front and end overhang of 1 inch over base cabinets. Ease edges to radius indicated for the following:
PART 3 - EXECUTION
3.1 INSTALLATION
A. Assemble countertops and complete fabrication at Project site to the extent that it was not completed in the shop.
1. Provide cutouts for appliances, plumbing fixtures, electrical work, and similar items. Locate openings accurately, and use templates or roughing-in diagrams to produce accurately sized and shaped openings. Sand edges of cutouts to remove splinters and burrs.
2. Seal edges of cutouts by saturating with varnish.
B. Field Jointing: Where possible, make in the same manner as shop jointing, using dowels, splines, adhesives, and fasteners recommended by manufacturer. Prepare edges to be joined in shop so Project-site processing of top and edge surfaces is not required. Locate field joints where shown on Shop Drawings.
1. Secure field joints in countertops with concealed clamping devices located within 6 inches of front and back edges and at intervals not exceeding 24 inches. Tighten according to manufacturer's written instructions to exert a constant, heavy-clamping pressure at joints.
C. Scribe and cut countertops to fit adjoining work, refinish cut surfaces, and repair damaged finish at cuts.
D. Countertop Installation: Anchor securely by screwing through corner blocks of base cabinets or other supports into underside of countertop.
1. Install countertops level and true in line. Use concealed shims as required to maintain not more than a 1/8-inch-in-96-inches variation from a straight, level plane.
2. Seal joints between countertop and backsplash, if any, and joints where countertop and backsplash abut walls with mildew-resistant silicone sealant or another permanently elastic sealing compound recommended by countertop material manufacturer.
E. Protection: Provide Kraft paper or other suitable covering over countertop surfaces, taped to underside of countertop at a minimum of 48 inches o.c. Remove protection at Substantial Completion.
END OF SECTION 123623.13
Section 224216.13 – Commercial Lavaratories Page 23
SECTION 224216.13 - COMMERCIAL LAVATORIES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Automatically operated lavatory faucets.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Include diagrams for power, signal, and control wiring of automatic faucets.
1.3 CLOSEOUT SUBMITTALS
A. Operation and maintenance data.
PART 2 - PRODUCTS
2.1 AUTOMATICALLY OPERATED LAVATORY FAUCETS
A. NSF Standard: Comply with NSF 61 and NSF 372 for faucet materials that will be in contact with potable water.
B. Lavatory Faucets - Automatic Type: Hardwired Electronic Sensor Operated, Mixing,:
1. Standards: ASME A112.18.1/CSA B125.1 and UL 1951.
2. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.
3. General: Include hot- and cold-water indicators; coordinate faucet inlets with supplies and fixture hole punchings; coordinate outlet with spout and fixture receptor.
4. Body Material: Commercial, solid-brass, or die-cast housing with brazed copper and brass waterway.
5. Finish: Polished chrome plate.
6. Spout: Swivel, gooseneck type.
7. Spout Outlet: Aerator.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install lavatories level and plumb in accordance with roughing-in drawings.
3.2 PIPING CONNECTIONS
A. Connect fixtures with water supplies, stops, and risers, and with traps, soil, waste, and vent piping. Use size fittings required to match fixtures.
3.3 ELECTRICAL CONNECTIONS
A. Connect wiring according to Section 260519 "Low-Voltage Electrical Power Conductors and Cables."
B. Install electrical devices furnished by manufacturer, but not factory mounted in accordance with NFPA 70 and NECA 1.
3.4 ADJUSTING
A. Operate and adjust lavatories and controls. Replace damaged and malfunctioning lavatories, fittings, and controls.
Section 224216.13 – Commercial Lavaratories Page 24
B. Install new batteries in battery-powered, electronic-sensor mechanisms.
3.5 CLEANING AND PROTECTION
A. After completing installation of lavatories, inspect and repair damaged finishes.
B. Clean lavatories, faucets, and other fittings with manufacturers' recommended cleaning methods and materials.
C. Provide protective covering for installed lavatories and fittings.
D. Do not allow use of lavatories for temporary facilities unless approved in writing by Owner.
END OF SECTION 224216.13
Section 233713.23 – Louvers Page 25
SECTION 233713.23 - LOUVERS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes louvers.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 LOUVERS
A. General: Provide manufacturer’s standard louvers of size, shape, capacity, and type indicated for complete installation.
B. Finish: Provide louvers with a baked enamel finish. Color selected by Engineer.
C. Substrate Compatibilities: Provide louvers with frame and sill types that are compatible with adjacent substrate, and are specifically manufactured to fit in construction openings.
D. Materials: Construct of galvanized steel or aluminum.
E. Sills: Provide formed metal sills of the same material and finish as the louver.
F. Face blade arrangement: Horizontal, spaced ¾ inch apart.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install registers and grilles level and plumb.
B. Outlets and Inlets Locations: Drawings indicate general arrangement of ducts, fittings, and accessories. Air outlet and inlet locations have been indicated to achieve design requirements for air volume, noise criteria, airflow pattern, throw, and pressure drop. Make final locations where indicated, as much as practical. For units installed in lay-in ceiling panels, locate units in the center of panel. Where architectural features or other items conflict with installation, notify Architect for a determination of final location.
C. Install registers and grilles with airtight connections to ducts and to allow service and maintenance of dampers, air extractors, and fire dampers.
3.2 ADJUSTING
A. After installation, adjust registers and grilles to air patterns indicated, or as directed, before starting air balancing.
END OF SECTION 233713.23
Section 260519 - Low-Voltage Cables Page 26
SECTION 260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Copper building wire rated 600 V or less.
2. Metal-clad cable, Type MC, rated 600 V or less.
3. Connectors, splices, and terminations rated 600 V and less.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Product Schedule: Indicate type, use, location, and termination locations.
1.3 INFORMATIONAL SUBMITTALS
A. Field quality-control reports.
PART 2 - PRODUCTS
2.1 COPPER BUILDING WIRE
A. Description: Flexible, insulated and uninsulated, drawn copper current-carrying conductor with an overall insulation layer or jacket, or both, rated 600 V or less.
B. Standards:
1. Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and use.
2. RoHS compliant.
3. Conductor and Cable Marking: Comply with wire and cable marking according to UL's "Wire and
Cable Marking and Application Guide."
C. Conductors: Copper, complying with ASTM B3 for bare annealed copper and with ASTM B8 for stranded conductors.
D. Conductor Insulation:
1. Type NM: Comply with UL 83 and UL 719.
2. Type RHH and Type RHW-2: Comply with UL 44.
3. Type USE-2 and Type SE: Comply with UL 854.
4. Type THHN and Type THWN-2: Comply with UL 83.
5. Type THW and Type THW-2: Comply with NEMA WC-70/ICEA S-95-658 and UL 83.
6. Type XHHW-2: Comply with UL 44.
2.2 METAL-CLAD CABLE, TYPE MC
A. Description: A factory assembly of one or more current-carrying insulated conductors in an overall metallic sheath.
B. Standards:
1. Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and use.
2. Comply with UL 1569.
3. Conductor and Cable Marking: Comply with wire and cable marking according to UL's "Wire and
Cable Marking and Application Guide."
C. Circuits:
Section 260519 - Low-Voltage Cables Page 27
1. Single circuit and multicircuit with color-coded conductors.
2. Power-Limited Fire-Alarm Circuits: Comply with UL 1424.
D. Conductors: Copper, complying with ASTM B3 for bare annealed copper and with ASTM B8 for stranded conductors.
E. Ground Conductor: Insulated.
F. Conductor Insulation:
1. Type TFN/THHN/THWN-2: Comply with UL 83.
2. Type XHHW-2: Comply with UL 44.
G. Armor: Steel or Aluminum, interlocked.
H. Jacket: PVC applied over armor.
2.3 CONNECTORS AND SPLICES
A. Description: Factory-fabricated connectors, splices, and lugs of size, ampacity rating, material, type, and class for application and service indicated; listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and use.
B. Jacketed Cable Connectors: For steel and aluminum jacketed cables, zinc die-cast with set screws, designed to connect conductors specified in this Section.
C. Lugs: One piece, seamless, designed to terminate conductors specified in this Section.
PART 3 - EXECUTION
3.1 CONDUCTOR MATERIAL APPLICATIONS
A. Feeders: Copper; solid for No. 10 AWG and smaller; stranded for No. 8 AWG and larger.
B. Branch Circuits: Copper, Solid for No. 12 AWG and smaller; stranded for No. 10 AWG and larger.
3.2 INSTALLATION OF CONDUCTORS AND CABLES
A. Conceal cables in finished walls, ceilings, and floors unless otherwise indicated.
B. Use manufacturer-approved pulling compound or lubricant where necessary; compound used must not deteriorate conductor or insulation. Do not exceed manufacturer's recommended maximum pulling tensions and sidewall pressure values.
C. Use pulling means, including fish tape, cable, rope, and basket-weave wire/cable grips, that will not damage cables or raceway.
D. Install exposed cables parallel and perpendicular to surfaces of exposed structural members, and follow surface contours where possible.
3.3 CONNECTIONS
A. Tighten electrical connectors and terminals according to manufacturer's published torque-tightening values.
If manufacturer's torque values are not indicated, use those specified in UL 486A-486B.
B. Make splices, terminations, and taps that are compatible with conductor material[ and that possess equivalent or better mechanical strength and insulation ratings than unspliced conductors].
END OF SECTION 260519
Section 265116 – Fluorescent Interior Lighting Page 28
SECTION 265116 - FLUORESCENT INTERIOR LIGHTING
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Interior fluorescent luminaires, lamps, and ballasts.
2. Luminaire supports.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product, arranged by designation.
B. Shop Drawings: For nonstandard or custom luminaires.
1. Include plans, elevations, sections, and mounting and attachment details.
2. Include details of luminaire assemblies. Indicate dimensions, weights, loads, required clearances,…