RFQ - StoresFire Door10-18-22~1.docx
DOCX document 19 KB Posted
- Attached to
- DHS SP- Kiley Replace Fire Doors
- Solicitation number
- 23-444DHS-DEVDI-B-33985
- Issued by
- Lake County, Illinois
About this file
This document is a Request for Quote (RFQ) issued by the Illinois Department of Human Services for the replacement of fire doors at the Ann Kiley Center facility in Waukegan, Illinois. The scope of work includes removing the existing double doors, frame, and associated hardware, and providing new galvanized, primed, and painted fire-rated doors and frame. The new doors must have a 1-hour fire rating certified by Underwriters Laboratories, and the frame must be properly installed, insulated, and anchored. The contractor must use industrial-level closers and hinges, and provide a new panic bar device and lockset. The project requires the contractor to be licensed, bonded, and insured, and all labor must be provided by common law employees of the contract holder.
The pricing terms and funding requirements are not specified in the document. There are no set-asides or incumbents mentioned, and the document does not provide information on the current environment or any renewal options.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Covid Clause Notice~45.docx | DOCX document | |
| RMU50 .docx | DOCX document | |
| Standard Certification~94.docx | DOCX document | |
| standard-terms-and-conditions~13.pdf | ||
| Mandatory Onsite Visit Guidance for Vendors~19.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Illinois Department of Human Services Ann Kiley Center
R E Q U E S T F O R Q U O T E
| Facility: | Ann Kiley Center | |
| Address: | 1401 Dugdale Rd | |
| City: | Waukegan, IL 60085 | |
| Contact: | Delourdes Roney, Methods and Procedures I | |
| Phone: | 847-249-0605 | |
| Fax: | 847-249-4587 | |
| E-Mail: | delourdes.roney@illinois.gov |
| Item |
| Specifications and Requirements: |
| Qty. |
Replace Stores/Food Service Fire Door Set (Double Door)
Remove double doors, frame, and other associated hardware including (but not limited to) closers, hinges, alarms, and thresholds and prepare opening for new frames.
Provide new galvanized, primed, and painted doors and frame (white). Doors shall be prepared and painted on 6 sides. Paint shall be of durable composition suitable for exterior metal doors. Door opening is approximately 72” x 88”.
Doors shall have 1½ hour fire rating certified by Underwriters Laboratories. Fire rating labels shall be affixed to doors and frame.
Frame shall be installed plumb, insulated, and properly anchored to openings and floors using appropriate fasteners, door clips, and other fastening hardware as may be required. Frames shall be caulked using urethane caulk.
New doors shall be installed observing proper clearances on all sides in accordance with industry standards. Fire rating labels shall be installed on both frame and doors.
Industrial-level closers and hinges shall be used. Closer closing rate shall be adjusted in accordance with industry standards.
Provide new full escutcheon mortise IC shell Von Duprin panic bar device and Corbin-Russwin - compatible IC lockset.
Construction waste must be removed from site by the end of each workday.
Notes:
- Measurements shall be verified by bidders before submitting bid.
- Contractor and technicians shall be required to present certification for being licensed, bonded and insured to perform requirements of the project.
- Subcontracting is not permitted. All labor must be provided by common law employees of the contract holder. The term “common law employee” in this solicitation is one who receives a W-2 directly from the contract holder. A person or entity who receives a form 1099 to report their compensation would not meet the definition of common law employee for this purpose.
- All repairs shall reflect installation standards provided by Door Hardware Institute/ANSI, and meet NFPA 80 (Standard for Fire Doors and other Opening Protectives).
*** To add additional lines put curser at right side of line and hit enter. ***
Vendor Name: __________________________________________________
Date: __________________________________________________
*IF THIS FORM IS NOT FILLED OUT IN ITS ENTIRETY THE QUOTE MAY BE DISQUALIFIED