rfp_1659_00_31_00_information_available_to_proposers.pdf
PDF 2 MB Posted
- Solicitation number
- BPM001659
- Issued by
- California
About this file
This document is an Information Available to Proposers notice for a Construction Manager at Risk (CMAR) with Guaranteed Maximum Price (GMP) project at Vista Detention Facility, issued by the County of San Diego Department of Procurement and Contracting. The project involves comprehensive infrastructure and facility upgrades including replacement of the intercom system, CCTV system, access control systems, security backbone system overhaul, anti-ligature improvements, new computer and monitor installation, wiring installation, and core drilling work. Design drawings are available for viewing at the Department of Procurement and Contracting offices located at 5560 Overland Avenue, San Diego, CA 92123, and appointments must be scheduled with the Procurement Contracting Officer; photographs and copies of plans are not permitted. The notice also references a January 13, 2026 Board Letter with Minute Order and CEQA Notice of Exemption, establishing the project's environmental compliance status.
The document includes a Limited Asbestos and Lead Pre-Work Survey dated February 5, 2026, conducted by the County's Department of Environmental Health and Quality at the Vista Detention Facility located at 325 South Melrose Drive, Vista, CA 92081. The survey found no asbestos in any sampled building materials and no high concentrations of lead (greater than 1.0 mg/cm²) in tested surfaces. However, the survey notes that not all suspect materials were comprehensively sampled and references historical data indicating areas where asbestos and lead are present at the facility. Proposers must comply with California Occupational Safety and Health Administration (Cal/OSHA) requirements, California Environmental Protection Agency regulations, and Air Pollution Control District Rule 1206 regarding worker protection, work practices, contractor certifications, and hazardous waste disposal. A copy of the survey report must be maintained on-site during all work activities to satisfy Air Pollution Control District requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| rfp_1659_00_11_19_request_for_proposal.pdf | ||
| rfp_1659_division_01_documents.pdf | ||
| rfp_1659_division_00_documents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00 31 00 Information Available to Proposers (Rev. 03/21/25) Page 1 of 1
00 31 00 INFORMATION AVAILABLE TO PROPOSERS
The information listed below and attached hereto is Information Available to Proposers. Refer to the General Conditions for additional information:
1.1 EXISTING CONDITIONS
1.1.1 Department of Environmental Health & Quality (DEHQ), Limited Asbestos Lead Pre Work Survey: Vista Detention Facility (February 5, 2026)
1.2 BOARD LETTERS
1.2.1 January 13, 2026, Board Letter with Minute Order and CEQA Notice of Exemption
1.3 DRAWINGS
1.3.1 The latest design drawings are available to view at the Department of Procurement and Contracting offices on the second floor of 5560 Overland Avenue, San Diego, CA 92123.
Contact the Procurement Contracting Officer to schedule an appointment to view them.
No photos or copies of the plans are allowed.
DEPARTMENT OF ENVIRONMENTAL HEALTH AND QUALITY
COMMUNITY HEALTH DIVISION
P.O. Box 129261, San Diego, CA 92112-9261
(858) 505-6700 or (800) 253-9933 www.sdcdehq.org
"Environmental and public health through leadership, partnership and science"
HEATHER BUONOMO
DIRECTOR OF ENVIRONMENTAL HEALTH
AMY HARBERT
DIRECTOR
February 5, 20265
TO: Charles (Trip) Miller, Project Manager Department of General Services
FROM: Rosa Daulo, Supervising Industrial Hygienist Department of Environmental Health and Quality
LIMITED ASBESTOS LEAD PRE WORK SURVEY: VISTA DETENTION FACILITY, 325
SOUTH MELROSE DRIVE, VISTA
The attached electronic staff report provides results of the above referenced project. The report specifies recommendations to reduce/eliminate any identified problems.
If you have further questions or desire a hard copy of this report and are unable to print from the electronic format, please contact Milad Yacoub, Industrial Hygienist at (858) 694-2118 or e-mail milad.yacoub@sdcounty.ca.gov.
ROSA DAULO, Supervising Industrial Hygienist Occupational Health Program Department of Environmental Health and Quality
RD: my: 002220 report.docx
Attachment(s) cc: dustin.faulkner@sdcounty.ca.gov milad.yacoub@sdcounty.ca.gov timothy.stewart@sdcounty.ca.gov mailto:milad.yacoub@sdcounty.ca.gov mailto:Milad.Yacoub@sdcounty.ca.gov
February 5, 2026
TO: Rosa Daulo, Supervising Industrial Hygienist Community Health Division Department of Environmental Health
FROM: Milad Yacoub, Industrial Hygienist
Occupational Health Program Community Health Division
LIMITED ASBESTOS LEAD PRE WORK SURVEY: VISTA DETENTION FACILITY, 325 SOUTH
MELROSE DRIVE, VISTA
SUMMARY
After a request by Charles (Trip) Miller, Project Manager Department of General Services (DGS), Occupational Health Program (OHP) staff conducted a limited asbestos and lead survey at the Vista Detention Facility (VDF) located at 325 South Melrose Drive, Vista, CA 92081. The survey was requested prior to work involving replacing the intercom system, CCTV system, anti-ligature improvements, installing new computers and monitors, access control, wiring, core drilling from one floor onto the next, and a complete security backbone system overhaul involving numerous systems.
The survey was conducted on January 28, 2026.
No asbestos was detected in any of the sampled building materials. Please note that not all suspect materials were sampled, therefore this is not a comprehensive asbestos survey.
None of the tested components were identified to contain high concentrations of lead [>1.0 milligrams per square centimeter (mg/cm2)]. All other tested surfaces should be assumed to contain lead at lower concentrations.
Note: If the scope of work expands to other areas that were not tested in this survey, an additional survey must be requested if no historical data is available. Attached are historical results identifying areas where asbestos and lead are present.
This report does not provide a scope of work for any disturbance or removal of asbestos and lead materials. It summarizes findings for all sampled materials analyzed for asbestos and lead content. A separate scope of work must be developed utilizing this document from which guidance can be given regarding the disturbance of materials containing asbestos and lead.
For more detailed information, please see the DISCUSSION and CONCLUSIONS/RECOMMENDATIONS sections that follow.
002220 2 February 5, 2026
DISCUSSION
OHP conducted an asbestos and lead survey at VDF located at 325 South Melrose Drive, Vista, CA 92081. The scope of work involves a complete security system overhaul where it would require drilling into the walls to install wires for the new security system, replacing the intercom system, and replacing the flooring tiles in various deputy stations. The survey was limited and focused on building materials potentially impacted by the proposed project. The survey was performed on January 28, 2026.
Asbestos
Samples of suspect asbestos materials were collected and submitted to EMSL Analytical for asbestos analysis using polarized light microscopy (PLM). All the sampled materials tested negative [none detected (ND)] for asbestos. The sample results are provided in the Asbestos Bulk Sample attachment.
Please note: A previous limited asbestos survey was conducted at this site which identified building materials that contained asbestos. The historical data can be reviewed in the attachments.
Lead-Based Paint
Representative painted surfaces and/or building components were analyzed using a Niton XL X-Ray Fluorescence Analyzer (XRF). An XRF is a direct reading instrument that can detect lead at high concentrations and measures and expresses lead concentrations in mg/cm2. According to the Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing, a sample containing 1.0 mg/cm2 or greater is a lead-based paint (i.e., a high concentration).
OHP analyzed various colors of paint and components from the structures. None of the components tested were identified to contain lead-based paint or “high” concentrations of lead. A comprehensive listing of the lead sampling results is attached. Note, lead could be present in lower amounts than specified in the attached results and employees must be protected accordingly per California Occupational Safety and Health Administration (Cal/OSHA) requirements. The sample results are provided in the Lead-Based Paint Samples attachment.
Please note: A previous limited lead survey was conducted at this site which identified building materials that contained lead. The historical data can be reviewed in the attachments.
CONCLUSIONS/RECOMMENDATIONS
1. DGS must inform all tenants and/or affected County personnel of the results of this survey.
Proposed future work activities that may impact materials noted in this report must be performed following regulatory requirements such as Cal/OSHA (e.g., https://www.dir.ca.gov/title8/1529.html; https://www.dir.ca.gov/title8/1532_1.html), California Environmental Protection Agency (Cal/EPA) hazardous waste disposal requirements, and other applicable ordinances or rules such as the Air Pollution Control District rule 1206. Asbestos and lead are highly regulated and many of the requirements address matters such as worker training, work practices and controls, contractor certifications, notification requirements, waste disposal etc.
2. As noted, lead materials that contain less than 1.0 mg/cm2 could have lead present in lower concentrations, therefore Cal/OSHA regulations must be followed to prevent potential employee exposure and/or property contamination.
https://www.dir.ca.gov/title8/1529.html https://www.dir.ca.gov/title8/1532_1.html)
002220 3 February 5, 2026
3. The survey was limited to only accessible materials within the scope of work as described. In addition, minimal destructive sampling methods were used to access materials. If suspect asbestos or lead materials not addressed in this report are discovered during work activities, then work should be stopped and OHP contacted for further assessment.
4. If the scope of work expands to other areas that were not tested in this survey, and there is no historical data available, then an additional survey should be requested.
5. A copy of the report must be kept on site during work activities to satisfy Air Pollution Control
District (APCD) requirements.
If you have any questions, please contact me.
Milad Yacoub, Industrial Hygienist CAC 25-7817 Expiration Date 02/21/2027 Occupational Health Program my: 002220 report.docx
Project ID: DEH2025-COPS-002220 Project Name: Pre-work Asbestos/Lead Survey: VDF Security
Collected By: Milad Yacoub, Certified Asbestos Consultant, #25-7817 Expiration Date 2/21/2027 Employer: County of San Diego Address: 5500 Overland Ave, San Diego, CA, 92123
Facility Name: North County Regional Center Site Address: 325 S MELROSE DR, VISTA, CA 92081
Owner: County of San Diego Owner Address: 5560 Overland Ave, San Diego, 92123
Lab Information: EMSL Analytical, Inc. (San Diego), 858-499-1303 Lab Address: 7725 Convoy Ct San Diego CA 92111 CA NVLAP Lab Code: 200855-0, EPA 600/R-93/116
NCRC - Vista Detention Facility Expansion DEH2018-COBS-000442
Date Collected: 01/28/2026
Sample # Material Description Sample Location Material Location
Asbestos Asbestos Type Friable Analysis
Type 01-Floor Tile 12"x12" Blue Floor Tile South House Stairs Step by Door ND N/A PLM 01-Mastic 12"x12" Blue Floor Tile Gray/Beige
Mastic South House Stairs Step by Door ND N/A PLM
02-Floor Tile 1 12"x12" Blue Floor Tile South House By Control Room Entrance ND N/A PLM 02-Floor Tile 2 Brown Floor Tile South House By Control Room Entrance ND N/A PLM 02-Mastic 1 12"x12" Blue Floor Tile Gray/Beige
Mastic South House By Control Room Entrance ND N/A PLM
02-Mastic 2 Floor Tile Yellow/Beige Mastic South House By Control Room Entrance ND N/A PLM 03 Gray/White Concrete Wall East South House S. Wall Janitor Closet ND N/A PLM 04 Gray/White Concrete Wall East South House S. Wall Janitor Wash Room ND N/A PLM 05-Base Cove Blue Base Cove Nurse's Station Around Column ND N/A PLM 05-Glue Yellow Base Cove Glue Nurse's Station Around Column ND N/A PLM
County of San Diego Department of Environmental Health and Quality
Asbestos Bulk Samples
ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;
SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite
DEHQ_CHD_OHPS_Samples_Asbestos_Bulk Run Date: 2/5/2026 9:26 AM
Attachment 1
05-Glue Yellow Base Cove Glue Nurse's Station Around Column ND N/A PLM 05-Joint compound White Base Cove Joint Compound Nurse's Station Around Column ND N/A PLM 06-Floor Tile 12"x12" Blue Floor Tile Nurse's Station Around Column ND N/A PLM 06-Joint compound 12"x12" Blue Floor Tile White Joint
Compound Nurse's Station Around Column ND N/A PLM
06-Mastic 12"x12" Blue Floor Tile Gray/Yellow Mastic
Nurse's Station Around Column ND N/A PLM
07-Base Coat Concrete Wall Nurse's Station W. Wall Behind Printer ND N/A PLM 07-Finish Coat Concrete Wall Nurse's Station W. Wall Behind Printer ND N/A PLM 08-Epoxy/Floor Coat
Epoxy/Floor Coat East House Deputy Station
Top Floor Stairs ND N/A PLM
09-Cove Base Black Base Cove East House Deputy Station
Top Floor Stairs Next To Door ND N/A PLM
09-Glue Base Cove Brown Glue East House Deputy Station
Top Floor Stairs Next To Door ND N/A PLM
10-Cove Base Black Base Cove East House Deputy Station
Upper Stairs ND N/A PLM
10-Glue 1 Base Cove Brown Glue East House Deputy Station
Upper Stairs ND N/A PLM
10-Glue 2 Stiar Tread Brown Glue East House Deputy Station
Upper Stairs ND N/A PLM
10-Stair Tread Gray Stiar Tread East House Deputy Station
Upper Stairs ND N/A PLM
11-Cementitious Material
Gray Cementitious Material East House Deputy Station
Lower Stairs ND N/A PLM
11-Mastic Stair Tread Black Mastic East House Deputy Station
Lower Stairs ND N/A PLM
11-Stair Tread Gray Stiar Tread East House Deputy Station
Lower Stairs ND N/A PLM
12-Cementitious Material
Stairs Steps Gray Cementitious Material
East House Deputy Station
Lower Stairs ND N/A PLM
12-Cove Base Stairs Steps Black Base Cove East House Deputy Station
Lower Stairs ND N/A PLM
12-Mastic Stairs Steps Base Cove Brown East House Deputy Lower Stairs ND N/A PLM ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;
SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite
DEHQ_CHD_OHPS_Samples_Asbestos_Bulk Run Date: 2/5/2026 9:26 AM
Mastic Station 13-Base Cove Stairs Black Base Cove East House Deputy
Station Lower Stairs ND N/A PLM
13-Glue Stairs Base Cove Black Glue East House Deputy Station
Lower Stairs ND N/A PLM
14-Drywall Wall Above Sink White Drywall East House Deputy Station
Lower Section (Basement) ND N/A PLM
14-Joint Compound Wall Above Sink White Joint Compound
East House Deputy Station
Lower Section (Basement) ND N/A PLM
15-Drywall Wall Above Toilet Brown/White Drywall
East House Deputy Station
Lower Section (Basement) ND N/A PLM
15-Joint Compound Wall Above Toilet White Joint Compound
East House Deputy Station
Lower Section (Basement) ND N/A PLM
16-Flooring Epoxy/Coat
Gray/Yellow Flooring Epoxy/Coat North House Deputy Station
456 Section Stairs ND N/A PLM
17-Flooring Epoxy/Coat
Gray/Yellow Flooring Epoxy/Coat North House Deputy Station
123 Section Stairs ND N/A PLM
18-Drywall N. Wall Brown/White Drywall North House Deputy Station
Lower Electrical Control Room
ND N/A PLM
18-Joint Compound N. Wall White Joint Compound North House Deputy Station
Lower Electrical Control Room
ND N/A PLM
19-Drywall W. Wall Brown/White Drywall North House Deputy Station
Lower Electrical Control Room
ND N/A PLM
19-Joint Compound W. Wall White Joint Compound North House Deputy Station
Lower Electrical Control Room
ND N/A PLM
20-Carpet Gray/Various/Beige Carpet Booking Counter Ramp Going Up To Work Stations
ND N/A PLM
20-Glue Clear Carpet Glue Booking Counter Ramp Going Up To Work Stations
ND N/A PLM
21-Base Cove Black Base Cove Booking Counter Under Work Station ND N/A PLM 21-Glue/Joint Compound
Base Cove Beige Glue/Joint Compound
Booking Counter Under Work Station ND N/A PLM
22-Carpet S. Section Various Colors Carpet Final Release Area Under Work Cabinet ND N/A PLM
ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;
SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite
DEHQ_CHD_OHPS_Samples_Asbestos_Bulk
22-Glue S. Section Various Colors Carpet Beige Glue
Final Release Area Under Work Cabinet ND N/A PLM
23-Base Cove S. Section Black Base Cove Final Release Area Under Work Cabinet ND N/A PLM 23-Glue S. Section Base Cove Beige Glue Final Release Area Under Work Cabinet ND N/A PLM 24-Joint Compound E. Wall Joint Compound Mail Intake Room by Card Access Panel ND N/A PLM 25-Carpet Gray/Various/Beige Carpet Information Lobby
Room S. Wall ND N/A PLM
25-Glue Carpet Beige/Clear Glue Information Lobby Room
S. Wall ND N/A PLM
25-Leveling Compound Like
Carpet White Leveling Compound Information Lobby Room
S. Wall ND N/A PLM
26-Base Cove Black Base Cove Information Lobby Room
S. Wall ND N/A PLM
26-Glue 1 Base Cove Beige Glue Information Lobby Room
S. Wall ND N/A PLM
26-Glue 2 Base Cove Yellow Glue Information Lobby Room
S. Wall ND N/A PLM
ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;
SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite
DEHQ_CHD_OHPS_Samples_Asbestos_Bulk
Field Sample#
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0910-205
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC - AWM Testing
NCRC-GS-
Drywall, Office N/A PLMOffice25-May-10 ND
NCRC-GS-
Drywall, Office N/A PLMOffice25-May-10 ND
NCRC-GS-
Joint Tape/Mud, Drywall Tape-Mud Office N/A PLMOffice25-May-10 ND
NCRC-GS-
Joint Tape/Mud, Drywall Tape-Mud Office N/A PLMOffice25-May-10 ND
NCRC-GS-
Paper, Black Paper Storage N/A PLMStorage25-May-10 ND
NCRC-GS-
Roofing Material, Roof Core Roof N/A PLMRoof25-May-10 ND
NCRC-GS-
Roofing Material, Roof Core Roof Parapet N/A PLMRoof Parapet25-May-10 ND
NCRC-GS-
Roofing Material, Roof Mastic Roof No PLMRoof25-May-10 Chrysotile15 %
NCRC-GS-
Roofing Material, Roof Mastic Roof No PLMRoof25-May-10 Chrysotile15 %
NCRC-GS-
Roofing Material, Shingle Exterior Cabinet N/A PLMCarport25-May-10 ND
NCRC-GS-
Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %
NCRC-GS-
Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %
NCRC-GS-
Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %
NCRC - Central Plant NCRC-M-01 Ceiling Material, 2'x2' CT w/
Fissures Supply Room N/A PLMMaintenance Shop Supply
Room & Office 03-Nov-06 ND
Thursday, February 5, 2026 Page 1 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Attachment 1.1
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-M-02 Ceiling Material, 2'x2' CT w/ Pinholes
Supply Room N/A PLMMaintenance Shop Supply Room & Office
03-Nov-06 ND
NCRC-M-
Cementitious Material, Cement Backsplash
Break Room No PLMMaintenance Shop03-Nov-06 Chrysotile2 %
NCRC-M-04 Drywall, Drywall Maintenance Shop Office N/A PLMMaintenance Shop Office03-Nov-06 ND
MCRC-
MC01
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC02
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC03
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC04
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC05
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC06
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
MCRC-
MC07
Fabric, white/beige wrap on various pipes/valves/fittings
N/A PLMOld Mechanical Room19-Mar-18 ND
91103-
NCRC-B2
Gasket/Packing, Boiler door gasket
Boiler door Yes PLMBoiler door11-Sep-03 ND
91103-
NCRC-B4
Gasket/Packing, Boiler opening gasket
Boiler opening Yes PLMBoiler opening11-Sep-03 ND
91103-
NCRC-B1
Insulation, Boiler door insulation Boiler door Yes PLMBoiler door11-Sep-03 ND
NCRC-Boil-
Insulation, Endcap F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Endcap F-105 PLMBoiler Room22-Sep-06 ND
Thursday, February 5, 2026 Page 2 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0607-073
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-Boil-
Insulation, Endcap F76-1 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Hot Water Tank F76-1 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Hot Water Tank F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Hot Water Tank F-105 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Elbow F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Elbow F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Elbow F-105 PLMBoiler Room22-Sep-06 ND
91103-
NCRC-B5
Insulation, Pipe hanger insulation 8 inch pipe hanger insulation Yes PLM 8 inch pipe hanger insulation11-Sep-03 ND
91103-
NCRC-B6
Insulation, Pipe hanger insulation Rear wall, 2 inch pipe hanger insulation on wall bracket
Yes PLM2 inch pipe hanger insulation on rear wall bracket
11-Sep-03 ND
NCRC-Boil-
Insulation, Pipe Run F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Run F76-2 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Run F-105 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Run F-105 PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND
NCRC-Boil-
Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND
Thursday, February 5, 2026 Page 3 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0607-073
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-Boil-
Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND
NCRC-01 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND
NCRC-02 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND
NCRC-03 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND
NCRC-M-05 Joint Tape/Mud, Drywall Tape-Mud Maintenance Shop Office N/A PLMMaintenance Shop Office03-Nov-06 ND
91103-
NCRC-B3
Mastic/Glue, Flashing material on base of pipe
Boiler door No PLMOnly one pipe in door11-Sep-03 ND
NCRC - Facilities Shop NCRC-G-01 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel
Station, A/C Shop 03-Nov-06 ND
NCRC-G-02 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop
03-Nov-06 ND
NCRC-G-03 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop
03-Nov-06 ND
NCRC-G-04 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop
03-Nov-06 ND
NCRC-G-05 Ceiling Material, 1'x4' CT A/C Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop
03-Nov-06 ND
NCRC-G-06 Drywall, Drywall Restroom N/A PLMRestroom03-Nov-06 ND
NCRC-G-07 Joint Tape/Mud, Drywall Tape-Mud Restroom N/A PLMRestroom03-Nov-06 ND
NCRC - Law Library
NCRC-LLT-
Baseboard, Baseboard/Glue Trailer: Hallway N/A PLMAttached Trailer16-Jan-18 ND
Thursday, February 5, 2026 Page 4 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
John-Ross Glueck 1718-167
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-LLT-
Baseboard, Baseboard/Glue Trailer: Staff Area N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LLT-
Caulking Compound, Caulking Trailer: Exterior, Side D Wall N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LLT-
Caulking Compound, Caulking Trailer: Exterior, Side A Wall N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: West Side N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Northwest Side N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Center N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Break Room N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Center N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Southwest Side N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes
Library: Northeast Side N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT Fissures w/ Pinholes
Trailer: Conference Room N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Ceiling Material, 2'x4' CT Fissures w/ Pinholes
Trailer: Office "B" N/A PLMAttached Trailer04-Jan-06 ND
Thursday, February 5, 2026 Page 5 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-LL-
Ceiling Material, 2'x4' CT Fissures w/ Pinholes
Trailer: "Staff" Room N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Library: Restroom N/A PLMRestroom & Telephone Closet04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Library: Behind Plaster N/A PLMThroughout Building04-Jan-06 ND
NCRC-LL-
Drywall, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND
NCRC-LL-
Drywall, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND
NCRC-LLT-
Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LL-
Joint Tape/Mud, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Joint Tape/Mud, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Joint Tape/Mud, Drywall Trailer: Computer Closet N/A PLMAttached Trailer04-Jan-06 ND
NCRC-LL-
Joint Tape/Mud, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND
NCRC-LLT-
Joint Tape/Mud, Drywall Trailer: Office B N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LLT-
Mastic/Glue, Carpet Trailer: Conf. Room N/A PLMAttached Trailer16-Jan-18 ND
Thursday, February 5, 2026 Page 6 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
John-Ross Glueck 1718-167
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-LLT-
Mastic/Glue, Carpet Trailer: Staff Area N/A PLMAttached Trailer16-Jan-18 ND
NCRC-LLT-
Mastic/Glue, Gray Roof Mastic Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile5 %
NCRC-LL-
Paper, Black Paper Library: Attic N/A PLMThroughout Building04-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Break Room N/A PLMThroughout Library04-Jan-06 ND
NCRC-LL-
Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room
04-Jan-06 ND
NCRC-LL-
Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room
04-Jan-06 ND
NCRC-LL-
Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room
04-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: West Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Northwest Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Center Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Break Room SW Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Southwest Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Library: Northeast Wall N/A PLMThroughout Building05-Jan-06 ND
NCRC-LL-
Plaster, Wall Mechanical Room: East Wall N/A PLMOutside Patio & Mechanical Room
05-Jan-06 ND
NCRC-11 Roofing Material, Roof, Flashing Pitch
Law Library building, roof, from rain gutter.
No PLMLaw library, main and annex buildings
12-Jun-96 Chrysotile4 %
Thursday, February 5, 2026 Page 7 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Van Vreeswyk, Rene 9596-0185
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-13 Roofing Material, Roof, Flashing Pitch
Law Library building, roof, from exhaust.
No PLMLaw library, main and annex buildings
12-Jun-96 Chrysotile<1 %
NCRC-10 Roofing Material, Roofing Core Law Library building, roof.
South-west side.
No PLMLaw library, main and annex buildings
12-Jun-96 Chrysotile18 %
NCRC-12 Roofing Material, Roofing Core Law Library building, roof, from northeast side.
No PLMLaw library, main and annex buildings
12-Jun-96 Chrysotile20 %
NCRC-LLT-
Roofing Material, Roofing Core Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile<1 %
NCRC-LLT-
Roofing Material, Roofing Core Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile<1 %
01 Stucco, white Electrical Rm #2, side B wall N/A PLMElectrical Rooms12-Apr-16 ND
02 Stucco, white Electrical Rm #1, side B wall N/A PLMElectrical Rooms12-Apr-16 ND
03 Stucco, white Patio Area, side B wall N/A PLMPatio Area12-Apr-16 Chrysotile<1 %
04 Stucco, white Exterior, side C wall N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %
05 Stucco, white Exterior, side D wall N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %
06 Stucco, white Exterior, side C eave N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %
07 Stucco, white Exterior, side C eave N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %
NCRC - North Building
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
NE Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
SJ1 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
Thursday, February 5, 2026 Page 8 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
N. Hallway (leading to VPS) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
SJ-5 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
Judge's Library N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
Hallway N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Ceiling Material, 1'x1' Concealed Spline CT
Dept. 5 Hallway N/A PLMThroughout "Old" Courthouse27-Jan-06 ND
VPS-06 Ceiling Material, 1'x1' Glued CT Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
VPS-12 Ceiling Material, 1'x1' Glued CT Detective Squad Room N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-04 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes
Basement: Hallway N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
VPS-21 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes
Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-24 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes
Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-13 Ceiling Material, 2'x2' CT w/ "Chicken Tracks"
Conference Room N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
NCRC-IT-
Ceiling Material, 2'x2' CT: "Pitted" with Pinholes
Hallway N/A PLMVarious areas throughout facility
26-May-06 ND
VPS-16 Ceiling Material, 2'x2' Lay-in CT w/ "Chicken Tracks"
Seargent Office N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-01 Ceiling Material, 2'x2' Lay-in CT w/ Fissures
Basement: Briefing Rm. N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
VPS-05 Ceiling Material, 2'x2' Lay-in CT w/ Fissures
Basement: Hallway N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
Thursday, February 5, 2026 Page 9 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-OC-
Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes
N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse
20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes
W. Hallway N/A PLMVarious Areas in "Old" Courthouse
20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes
Janitor's Closet N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes
Basement: C03 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes
Basement: C031 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes
N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse
20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes
Dept. 9 Courtroom N/A PLMVarious Areas in "Old" Courthouse
27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes
Basement: C016 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes
Basement: C015 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
C121 (Hallway) N/A PLMVarious Areas in "Old" Courthouse
20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse
20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Interview Room N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Janitor's Closet N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Basement: C018 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Basement: C011 N/A PLMVarious Areas in Basement27-Jan-06 ND
Thursday, February 5, 2026 Page 10 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Basement: C04 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Basement: C03 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes
Basement: C015 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-
VPS-01
Ceiling Material, 2'x4' CT "Pitted" w/ Pinholes
Squad Room N/A PLMVarious ares of VPS27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
SW Hallway N/A PLMSW Hallway & Copy Room20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Copy Room N/A PLMSW Hallway & Copy Room20-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Family Service Break Room N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Family Service Hallway N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Family Service Mail Room N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Lobby N/A PLMVarious Areas in "Old" Courthouse
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Suite 500 Hallway N/A PLMVarious Areas in "Old" Courthouse
27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Suite 500 Conference Room N/A PLMVarious Areas in "Old" Courthouse
27-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'X4' CT "Sandpaper" Finish
Suite 500 Substance Abuse N/A PLMVarious Areas in "Old" Courthouse
27-Jan-06 ND
VPS-02 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"
Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
VPS-03 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"
Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse
25-Oct-06 ND
Thursday, February 5, 2026 Page 11 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
VPS-10 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"
Detective Squad Room N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
NCRC-OC-
Ceiling Material, 2'x4' Drywall CT S. Men's Restroom N/A PLMS. Restrooms; Family Service Restrooms
23-Jan-06 ND
NCRC-OC-
Ceiling Material, 2'x4' Drywall CT Family Services Men's Restroom
N/A PLMS. Restrooms; Family Service Restrooms
23-Jan-06 ND
NCRC-OC-
Drywall, Drywall SJ1 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Drywall, Drywall C121 (Hallway) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Drywall, Drywall W. Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Drywall, Drywall SW Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND
NCRC-OC-
Drywall, Drywall Janitor's Closet N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Family Service Break Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Family Service Hallway N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Family Service Mail Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Lobby N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Interview Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND
NCRC-OC-
Drywall, Drywall Suite 500 Hallway N/A PLMThroughout "Old" Courthouse27-Jan-06 ND
NCRC-OC-
Drywall, Drywall Suite 500 Conference Room N/A PLMThroughout "Old" Courthouse27-Jan-06 ND
Thursday, February 5, 2026 Page 12 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-OC-
Drywall, Drywall Suite 500 Substance Abuse N/A PLMVarious Areas in "Old" Courthouse
27-Jan-06 ND
NCRC-OC-
Drywall, Drywall Basement: C018 N/A PLMVarious Areas in Basement27-Jan-06 ND
NCRC-OC-
Drywall, Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
NCRC-
VPS-04
Drywall, Drywall Squad Room N/A PLMThroughout Facility27-Jan-06 ND
VPS-14 Drywall, Drywall Conference Room N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-17 Drywall, Drywall Seargent Office N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-20 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-22 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-25 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
VPS-28 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
NCRC-OC-
Drywall, Vinyl Drywall C121 (Hallway) N/A PLMC121 (Hallway)20-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement: C04 N/A PLMThroughout Basement27-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement: C03 N/A PLMThroughout Basement27-Jan-06 ND
Thursday, February 5, 2026 Page 13 of 45
ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.
Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.
Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.
Date Collected
Project #:Collected By:
Material Description Friable Analysis Type Asbestos Content and Type
Asbestos Bulk Sample Report Sampling Location:
North County Regional Center
Mark Middlestead 0506-079
Sample Location Material Location
325 S Melrose Drive, Vista
NCRC-OC-
Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
NCRC-OC-
Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND
VPS-30 Drywall, Vinyl Drywall Basement: Traffic N/A PLMVarious areas of VPS/Courthouse
25-Oct-06 ND
NCRC-OC-
Floor Covering - Linoleum, Cream-color Linoleum
Basement: C015 (Men's Restroom)
Yes PLMC015 & C01627-Jan-06 Chrysotile10 %
VPS-01 Floor Covering - Misc., Terrazo Sheriff Public Hallway N/A PLMSheriff Public Hallway25-Mar-10 ND
VSS-01 Floor Covering - Tile, 1'x1' Off-white FT
VPS: Room…