This document is an Information Available to Proposers notice for a Construction Manager at Risk (CMAR) with Guaranteed Maximum Price (GMP) project at Vista Detention Facility, issued by the County of San Diego Department of Procurement and Contracting. The project involves comprehensive infrastructure and facility upgrades including replacement of the intercom system, CCTV system, access control systems, security backbone system overhaul, anti-ligature improvements, new computer and monitor installation, wiring installation, and core drilling work. Design drawings are available for viewing at the Department of Procurement and Contracting offices located at 5560 Overland Avenue, San Diego, CA 92123, and appointments must be scheduled with the Procurement Contracting Officer; photographs and copies of plans are not permitted. The notice also references a January 13, 2026 Board Letter with Minute Order and CEQA Notice of Exemption, establishing the project's environmental compliance status.

The document includes a Limited Asbestos and Lead Pre-Work Survey dated February 5, 2026, conducted by the County's Department of Environmental Health and Quality at the Vista Detention Facility located at 325 South Melrose Drive, Vista, CA 92081. The survey found no asbestos in any sampled building materials and no high concentrations of lead (greater than 1.0 mg/cm²) in tested surfaces. However, the survey notes that not all suspect materials were comprehensively sampled and references historical data indicating areas where asbestos and lead are present at the facility. Proposers must comply with California Occupational Safety and Health Administration (Cal/OSHA) requirements, California Environmental Protection Agency regulations, and Air Pollution Control District Rule 1206 regarding worker protection, work practices, contractor certifications, and hazardous waste disposal. A copy of the survey report must be maintained on-site during all work activities to satisfy Air Pollution Control District requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00 31 00 Information Available to Proposers (Rev. 03/21/25) Page 1 of 1

00 31 00 INFORMATION AVAILABLE TO PROPOSERS

The information listed below and attached hereto is Information Available to Proposers. Refer to the General Conditions for additional information:

1.1 EXISTING CONDITIONS

1.1.1 Department of Environmental Health & Quality (DEHQ), Limited Asbestos Lead Pre Work Survey: Vista Detention Facility (February 5, 2026)

1.2 BOARD LETTERS

1.2.1 January 13, 2026, Board Letter with Minute Order and CEQA Notice of Exemption

1.3 DRAWINGS

1.3.1 The latest design drawings are available to view at the Department of Procurement and Contracting offices on the second floor of 5560 Overland Avenue, San Diego, CA 92123.

Contact the Procurement Contracting Officer to schedule an appointment to view them.

No photos or copies of the plans are allowed.

DEPARTMENT OF ENVIRONMENTAL HEALTH AND QUALITY

COMMUNITY HEALTH DIVISION

P.O. Box 129261, San Diego, CA 92112-9261

(858) 505-6700 or (800) 253-9933 www.sdcdehq.org

"Environmental and public health through leadership, partnership and science"

HEATHER BUONOMO

DIRECTOR OF ENVIRONMENTAL HEALTH

AMY HARBERT

DIRECTOR

February 5, 20265

TO: Charles (Trip) Miller, Project Manager Department of General Services

FROM: Rosa Daulo, Supervising Industrial Hygienist Department of Environmental Health and Quality

LIMITED ASBESTOS LEAD PRE WORK SURVEY: VISTA DETENTION FACILITY, 325

SOUTH MELROSE DRIVE, VISTA

The attached electronic staff report provides results of the above referenced project. The report specifies recommendations to reduce/eliminate any identified problems.

If you have further questions or desire a hard copy of this report and are unable to print from the electronic format, please contact Milad Yacoub, Industrial Hygienist at (858) 694-2118 or e-mail milad.yacoub@sdcounty.ca.gov.

ROSA DAULO, Supervising Industrial Hygienist Occupational Health Program Department of Environmental Health and Quality

RD: my: 002220 report.docx

Attachment(s) cc: dustin.faulkner@sdcounty.ca.gov milad.yacoub@sdcounty.ca.gov timothy.stewart@sdcounty.ca.gov mailto:milad.yacoub@sdcounty.ca.gov mailto:Milad.Yacoub@sdcounty.ca.gov

February 5, 2026

TO: Rosa Daulo, Supervising Industrial Hygienist Community Health Division Department of Environmental Health

FROM: Milad Yacoub, Industrial Hygienist

Occupational Health Program Community Health Division

LIMITED ASBESTOS LEAD PRE WORK SURVEY: VISTA DETENTION FACILITY, 325 SOUTH

MELROSE DRIVE, VISTA

SUMMARY

After a request by Charles (Trip) Miller, Project Manager Department of General Services (DGS), Occupational Health Program (OHP) staff conducted a limited asbestos and lead survey at the Vista Detention Facility (VDF) located at 325 South Melrose Drive, Vista, CA 92081. The survey was requested prior to work involving replacing the intercom system, CCTV system, anti-ligature improvements, installing new computers and monitors, access control, wiring, core drilling from one floor onto the next, and a complete security backbone system overhaul involving numerous systems.

The survey was conducted on January 28, 2026.

No asbestos was detected in any of the sampled building materials. Please note that not all suspect materials were sampled, therefore this is not a comprehensive asbestos survey.

None of the tested components were identified to contain high concentrations of lead [>1.0 milligrams per square centimeter (mg/cm2)]. All other tested surfaces should be assumed to contain lead at lower concentrations.

Note: If the scope of work expands to other areas that were not tested in this survey, an additional survey must be requested if no historical data is available. Attached are historical results identifying areas where asbestos and lead are present.

This report does not provide a scope of work for any disturbance or removal of asbestos and lead materials. It summarizes findings for all sampled materials analyzed for asbestos and lead content. A separate scope of work must be developed utilizing this document from which guidance can be given regarding the disturbance of materials containing asbestos and lead.

For more detailed information, please see the DISCUSSION and CONCLUSIONS/RECOMMENDATIONS sections that follow.

002220 2 February 5, 2026

DISCUSSION

OHP conducted an asbestos and lead survey at VDF located at 325 South Melrose Drive, Vista, CA 92081. The scope of work involves a complete security system overhaul where it would require drilling into the walls to install wires for the new security system, replacing the intercom system, and replacing the flooring tiles in various deputy stations. The survey was limited and focused on building materials potentially impacted by the proposed project. The survey was performed on January 28, 2026.

Asbestos

Samples of suspect asbestos materials were collected and submitted to EMSL Analytical for asbestos analysis using polarized light microscopy (PLM). All the sampled materials tested negative [none detected (ND)] for asbestos. The sample results are provided in the Asbestos Bulk Sample attachment.

Please note: A previous limited asbestos survey was conducted at this site which identified building materials that contained asbestos. The historical data can be reviewed in the attachments.

Lead-Based Paint

Representative painted surfaces and/or building components were analyzed using a Niton XL X-Ray Fluorescence Analyzer (XRF). An XRF is a direct reading instrument that can detect lead at high concentrations and measures and expresses lead concentrations in mg/cm2. According to the Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing, a sample containing 1.0 mg/cm2 or greater is a lead-based paint (i.e., a high concentration).

OHP analyzed various colors of paint and components from the structures. None of the components tested were identified to contain lead-based paint or “high” concentrations of lead. A comprehensive listing of the lead sampling results is attached. Note, lead could be present in lower amounts than specified in the attached results and employees must be protected accordingly per California Occupational Safety and Health Administration (Cal/OSHA) requirements. The sample results are provided in the Lead-Based Paint Samples attachment.

Please note: A previous limited lead survey was conducted at this site which identified building materials that contained lead. The historical data can be reviewed in the attachments.

CONCLUSIONS/RECOMMENDATIONS

1. DGS must inform all tenants and/or affected County personnel of the results of this survey.

Proposed future work activities that may impact materials noted in this report must be performed following regulatory requirements such as Cal/OSHA (e.g., https://www.dir.ca.gov/title8/1529.html; https://www.dir.ca.gov/title8/1532_1.html), California Environmental Protection Agency (Cal/EPA) hazardous waste disposal requirements, and other applicable ordinances or rules such as the Air Pollution Control District rule 1206. Asbestos and lead are highly regulated and many of the requirements address matters such as worker training, work practices and controls, contractor certifications, notification requirements, waste disposal etc.

2. As noted, lead materials that contain less than 1.0 mg/cm2 could have lead present in lower concentrations, therefore Cal/OSHA regulations must be followed to prevent potential employee exposure and/or property contamination.

https://www.dir.ca.gov/title8/1529.html https://www.dir.ca.gov/title8/1532_1.html)

002220 3 February 5, 2026

3. The survey was limited to only accessible materials within the scope of work as described. In addition, minimal destructive sampling methods were used to access materials. If suspect asbestos or lead materials not addressed in this report are discovered during work activities, then work should be stopped and OHP contacted for further assessment.

4. If the scope of work expands to other areas that were not tested in this survey, and there is no historical data available, then an additional survey should be requested.

5. A copy of the report must be kept on site during work activities to satisfy Air Pollution Control

District (APCD) requirements.

If you have any questions, please contact me.

Milad Yacoub, Industrial Hygienist CAC 25-7817 Expiration Date 02/21/2027 Occupational Health Program my: 002220 report.docx

Project ID: DEH2025-COPS-002220 Project Name: Pre-work Asbestos/Lead Survey: VDF Security

Collected By: Milad Yacoub, Certified Asbestos Consultant, #25-7817 Expiration Date 2/21/2027 Employer: County of San Diego Address: 5500 Overland Ave, San Diego, CA, 92123

Facility Name: North County Regional Center Site Address: 325 S MELROSE DR, VISTA, CA 92081

Owner: County of San Diego Owner Address: 5560 Overland Ave, San Diego, 92123

Lab Information: EMSL Analytical, Inc. (San Diego), 858-499-1303 Lab Address: 7725 Convoy Ct San Diego CA 92111 CA NVLAP Lab Code: 200855-0, EPA 600/R-93/116

NCRC - Vista Detention Facility Expansion DEH2018-COBS-000442

Date Collected: 01/28/2026

Sample # Material Description Sample Location Material Location

Asbestos Asbestos Type Friable Analysis

Type 01-Floor Tile 12"x12" Blue Floor Tile South House Stairs Step by Door ND N/A PLM 01-Mastic 12"x12" Blue Floor Tile Gray/Beige

Mastic South House Stairs Step by Door ND N/A PLM

02-Floor Tile 1 12"x12" Blue Floor Tile South House By Control Room Entrance ND N/A PLM 02-Floor Tile 2 Brown Floor Tile South House By Control Room Entrance ND N/A PLM 02-Mastic 1 12"x12" Blue Floor Tile Gray/Beige

Mastic South House By Control Room Entrance ND N/A PLM

02-Mastic 2 Floor Tile Yellow/Beige Mastic South House By Control Room Entrance ND N/A PLM 03 Gray/White Concrete Wall East South House S. Wall Janitor Closet ND N/A PLM 04 Gray/White Concrete Wall East South House S. Wall Janitor Wash Room ND N/A PLM 05-Base Cove Blue Base Cove Nurse's Station Around Column ND N/A PLM 05-Glue Yellow Base Cove Glue Nurse's Station Around Column ND N/A PLM

County of San Diego Department of Environmental Health and Quality

Asbestos Bulk Samples

ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;

SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite

DEHQ_CHD_OHPS_Samples_Asbestos_Bulk Run Date: 2/5/2026 9:26 AM

Attachment 1

05-Glue Yellow Base Cove Glue Nurse's Station Around Column ND N/A PLM 05-Joint compound White Base Cove Joint Compound Nurse's Station Around Column ND N/A PLM 06-Floor Tile 12"x12" Blue Floor Tile Nurse's Station Around Column ND N/A PLM 06-Joint compound 12"x12" Blue Floor Tile White Joint

Compound Nurse's Station Around Column ND N/A PLM

06-Mastic 12"x12" Blue Floor Tile Gray/Yellow Mastic

Nurse's Station Around Column ND N/A PLM

07-Base Coat Concrete Wall Nurse's Station W. Wall Behind Printer ND N/A PLM 07-Finish Coat Concrete Wall Nurse's Station W. Wall Behind Printer ND N/A PLM 08-Epoxy/Floor Coat

Epoxy/Floor Coat East House Deputy Station

Top Floor Stairs ND N/A PLM

09-Cove Base Black Base Cove East House Deputy Station

Top Floor Stairs Next To Door ND N/A PLM

09-Glue Base Cove Brown Glue East House Deputy Station

Top Floor Stairs Next To Door ND N/A PLM

10-Cove Base Black Base Cove East House Deputy Station

Upper Stairs ND N/A PLM

10-Glue 1 Base Cove Brown Glue East House Deputy Station

Upper Stairs ND N/A PLM

10-Glue 2 Stiar Tread Brown Glue East House Deputy Station

Upper Stairs ND N/A PLM

10-Stair Tread Gray Stiar Tread East House Deputy Station

Upper Stairs ND N/A PLM

11-Cementitious Material

Gray Cementitious Material East House Deputy Station

Lower Stairs ND N/A PLM

11-Mastic Stair Tread Black Mastic East House Deputy Station

Lower Stairs ND N/A PLM

11-Stair Tread Gray Stiar Tread East House Deputy Station

Lower Stairs ND N/A PLM

12-Cementitious Material

Stairs Steps Gray Cementitious Material

East House Deputy Station

Lower Stairs ND N/A PLM

12-Cove Base Stairs Steps Black Base Cove East House Deputy Station

Lower Stairs ND N/A PLM

12-Mastic Stairs Steps Base Cove Brown East House Deputy Lower Stairs ND N/A PLM ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;

SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite

DEHQ_CHD_OHPS_Samples_Asbestos_Bulk Run Date: 2/5/2026 9:26 AM

Mastic Station 13-Base Cove Stairs Black Base Cove East House Deputy

Station Lower Stairs ND N/A PLM

13-Glue Stairs Base Cove Black Glue East House Deputy Station

Lower Stairs ND N/A PLM

14-Drywall Wall Above Sink White Drywall East House Deputy Station

Lower Section (Basement) ND N/A PLM

14-Joint Compound Wall Above Sink White Joint Compound

East House Deputy Station

Lower Section (Basement) ND N/A PLM

15-Drywall Wall Above Toilet Brown/White Drywall

East House Deputy Station

Lower Section (Basement) ND N/A PLM

15-Joint Compound Wall Above Toilet White Joint Compound

East House Deputy Station

Lower Section (Basement) ND N/A PLM

16-Flooring Epoxy/Coat

Gray/Yellow Flooring Epoxy/Coat North House Deputy Station

456 Section Stairs ND N/A PLM

17-Flooring Epoxy/Coat

Gray/Yellow Flooring Epoxy/Coat North House Deputy Station

123 Section Stairs ND N/A PLM

18-Drywall N. Wall Brown/White Drywall North House Deputy Station

Lower Electrical Control Room

ND N/A PLM

18-Joint Compound N. Wall White Joint Compound North House Deputy Station

Lower Electrical Control Room

ND N/A PLM

19-Drywall W. Wall Brown/White Drywall North House Deputy Station

Lower Electrical Control Room

ND N/A PLM

19-Joint Compound W. Wall White Joint Compound North House Deputy Station

Lower Electrical Control Room

ND N/A PLM

20-Carpet Gray/Various/Beige Carpet Booking Counter Ramp Going Up To Work Stations

ND N/A PLM

20-Glue Clear Carpet Glue Booking Counter Ramp Going Up To Work Stations

ND N/A PLM

21-Base Cove Black Base Cove Booking Counter Under Work Station ND N/A PLM 21-Glue/Joint Compound

Base Cove Beige Glue/Joint Compound

Booking Counter Under Work Station ND N/A PLM

22-Carpet S. Section Various Colors Carpet Final Release Area Under Work Cabinet ND N/A PLM

ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;

SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite

DEHQ_CHD_OHPS_Samples_Asbestos_Bulk

22-Glue S. Section Various Colors Carpet Beige Glue

Final Release Area Under Work Cabinet ND N/A PLM

23-Base Cove S. Section Black Base Cove Final Release Area Under Work Cabinet ND N/A PLM 23-Glue S. Section Base Cove Beige Glue Final Release Area Under Work Cabinet ND N/A PLM 24-Joint Compound E. Wall Joint Compound Mail Intake Room by Card Access Panel ND N/A PLM 25-Carpet Gray/Various/Beige Carpet Information Lobby

Room S. Wall ND N/A PLM

25-Glue Carpet Beige/Clear Glue Information Lobby Room

S. Wall ND N/A PLM

25-Leveling Compound Like

Carpet White Leveling Compound Information Lobby Room

S. Wall ND N/A PLM

26-Base Cove Black Base Cove Information Lobby Room

S. Wall ND N/A PLM

26-Glue 1 Base Cove Beige Glue Information Lobby Room

S. Wall ND N/A PLM

26-Glue 2 Base Cove Yellow Glue Information Lobby Room

S. Wall ND N/A PLM

ND = None Detected; N/A = Not Applicable; PLM = Polarized Light Microscopy; XRD = X-Ray Diffraction; TEM = Transmission Electron Microscopy;

SEM = Scanning Electron Microscopy Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite and Anthophyllite

DEHQ_CHD_OHPS_Samples_Asbestos_Bulk

Field Sample#

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0910-205

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC - AWM Testing

NCRC-GS-

Drywall, Office N/A PLMOffice25-May-10 ND

NCRC-GS-

Drywall, Office N/A PLMOffice25-May-10 ND

NCRC-GS-

Joint Tape/Mud, Drywall Tape-Mud Office N/A PLMOffice25-May-10 ND

NCRC-GS-

Joint Tape/Mud, Drywall Tape-Mud Office N/A PLMOffice25-May-10 ND

NCRC-GS-

Paper, Black Paper Storage N/A PLMStorage25-May-10 ND

NCRC-GS-

Roofing Material, Roof Core Roof N/A PLMRoof25-May-10 ND

NCRC-GS-

Roofing Material, Roof Core Roof Parapet N/A PLMRoof Parapet25-May-10 ND

NCRC-GS-

Roofing Material, Roof Mastic Roof No PLMRoof25-May-10 Chrysotile15 %

NCRC-GS-

Roofing Material, Roof Mastic Roof No PLMRoof25-May-10 Chrysotile15 %

NCRC-GS-

Roofing Material, Shingle Exterior Cabinet N/A PLMCarport25-May-10 ND

NCRC-GS-

Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %

NCRC-GS-

Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %

NCRC-GS-

Stucco, Exterior No PLMExterior25-May-10 Chrysotile<1 %

NCRC - Central Plant NCRC-M-01 Ceiling Material, 2'x2' CT w/

Fissures Supply Room N/A PLMMaintenance Shop Supply

Room & Office 03-Nov-06 ND

Thursday, February 5, 2026 Page 1 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Attachment 1.1

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-M-02 Ceiling Material, 2'x2' CT w/ Pinholes

Supply Room N/A PLMMaintenance Shop Supply Room & Office

03-Nov-06 ND

NCRC-M-

Cementitious Material, Cement Backsplash

Break Room No PLMMaintenance Shop03-Nov-06 Chrysotile2 %

NCRC-M-04 Drywall, Drywall Maintenance Shop Office N/A PLMMaintenance Shop Office03-Nov-06 ND

MCRC-

MC01

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC02

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC03

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC04

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC05

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC06

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

MCRC-

MC07

Fabric, white/beige wrap on various pipes/valves/fittings

N/A PLMOld Mechanical Room19-Mar-18 ND

91103-

NCRC-B2

Gasket/Packing, Boiler door gasket

Boiler door Yes PLMBoiler door11-Sep-03 ND

91103-

NCRC-B4

Gasket/Packing, Boiler opening gasket

Boiler opening Yes PLMBoiler opening11-Sep-03 ND

91103-

NCRC-B1

Insulation, Boiler door insulation Boiler door Yes PLMBoiler door11-Sep-03 ND

NCRC-Boil-

Insulation, Endcap F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Endcap F-105 PLMBoiler Room22-Sep-06 ND

Thursday, February 5, 2026 Page 2 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0607-073

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-Boil-

Insulation, Endcap F76-1 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Hot Water Tank F76-1 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Hot Water Tank F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Hot Water Tank F-105 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Elbow F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Elbow F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Elbow F-105 PLMBoiler Room22-Sep-06 ND

91103-

NCRC-B5

Insulation, Pipe hanger insulation 8 inch pipe hanger insulation Yes PLM 8 inch pipe hanger insulation11-Sep-03 ND

91103-

NCRC-B6

Insulation, Pipe hanger insulation Rear wall, 2 inch pipe hanger insulation on wall bracket

Yes PLM2 inch pipe hanger insulation on rear wall bracket

11-Sep-03 ND

NCRC-Boil-

Insulation, Pipe Run F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Run F76-2 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Run F-105 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Run F-105 PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND

NCRC-Boil-

Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND

Thursday, February 5, 2026 Page 3 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0607-073

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-Boil-

Insulation, Pipe Run F-105 - Soft Water PLMBoiler Room22-Sep-06 ND

NCRC-01 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND

NCRC-02 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND

NCRC-03 Insulation, White fibrous TSI Boiler end Yes PLMMechanical Room07-Jul-15 ND

NCRC-M-05 Joint Tape/Mud, Drywall Tape-Mud Maintenance Shop Office N/A PLMMaintenance Shop Office03-Nov-06 ND

91103-

NCRC-B3

Mastic/Glue, Flashing material on base of pipe

Boiler door No PLMOnly one pipe in door11-Sep-03 ND

NCRC - Facilities Shop NCRC-G-01 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel

Station, A/C Shop 03-Nov-06 ND

NCRC-G-02 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop

03-Nov-06 ND

NCRC-G-03 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop

03-Nov-06 ND

NCRC-G-04 Ceiling Material, 1'x4' CT Plumbing/Security Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop

03-Nov-06 ND

NCRC-G-05 Ceiling Material, 1'x4' CT A/C Shop N/A PLMPlumbing/Security Shop, Fuel Station, A/C Shop

03-Nov-06 ND

NCRC-G-06 Drywall, Drywall Restroom N/A PLMRestroom03-Nov-06 ND

NCRC-G-07 Joint Tape/Mud, Drywall Tape-Mud Restroom N/A PLMRestroom03-Nov-06 ND

NCRC - Law Library

NCRC-LLT-

Baseboard, Baseboard/Glue Trailer: Hallway N/A PLMAttached Trailer16-Jan-18 ND

Thursday, February 5, 2026 Page 4 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

John-Ross Glueck 1718-167

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-LLT-

Baseboard, Baseboard/Glue Trailer: Staff Area N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LLT-

Caulking Compound, Caulking Trailer: Exterior, Side D Wall N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LLT-

Caulking Compound, Caulking Trailer: Exterior, Side A Wall N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: West Side N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Northwest Side N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Center N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Break Room N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Center N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Southwest Side N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT "Chicken Tracks" w/ Pinholes

Library: Northeast Side N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT Fissures w/ Pinholes

Trailer: Conference Room N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Ceiling Material, 2'x4' CT Fissures w/ Pinholes

Trailer: Office "B" N/A PLMAttached Trailer04-Jan-06 ND

Thursday, February 5, 2026 Page 5 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-LL-

Ceiling Material, 2'x4' CT Fissures w/ Pinholes

Trailer: "Staff" Room N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Library: Restroom N/A PLMRestroom & Telephone Closet04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Library: Behind Plaster N/A PLMThroughout Building04-Jan-06 ND

NCRC-LL-

Drywall, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND

NCRC-LL-

Drywall, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND

NCRC-LLT-

Drywall, Drywall Trailer: Hallway N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LL-

Joint Tape/Mud, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Joint Tape/Mud, Drywall Trailer: Hallway N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Joint Tape/Mud, Drywall Trailer: Computer Closet N/A PLMAttached Trailer04-Jan-06 ND

NCRC-LL-

Joint Tape/Mud, Drywall Library: Telephone Closet N/A PLMRestroom & Telephone Closet05-Jan-06 ND

NCRC-LLT-

Joint Tape/Mud, Drywall Trailer: Office B N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LLT-

Mastic/Glue, Carpet Trailer: Conf. Room N/A PLMAttached Trailer16-Jan-18 ND

Thursday, February 5, 2026 Page 6 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

John-Ross Glueck 1718-167

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-LLT-

Mastic/Glue, Carpet Trailer: Staff Area N/A PLMAttached Trailer16-Jan-18 ND

NCRC-LLT-

Mastic/Glue, Gray Roof Mastic Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile5 %

NCRC-LL-

Paper, Black Paper Library: Attic N/A PLMThroughout Building04-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Break Room N/A PLMThroughout Library04-Jan-06 ND

NCRC-LL-

Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room

04-Jan-06 ND

NCRC-LL-

Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room

04-Jan-06 ND

NCRC-LL-

Plaster, Wall Outside Patio - Elect. Closet N/A PLMOutside Patio & Mechanical Room

04-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: West Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Northwest Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Center Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Break Room SW Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Southwest Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Library: Northeast Wall N/A PLMThroughout Building05-Jan-06 ND

NCRC-LL-

Plaster, Wall Mechanical Room: East Wall N/A PLMOutside Patio & Mechanical Room

05-Jan-06 ND

NCRC-11 Roofing Material, Roof, Flashing Pitch

Law Library building, roof, from rain gutter.

No PLMLaw library, main and annex buildings

12-Jun-96 Chrysotile4 %

Thursday, February 5, 2026 Page 7 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Van Vreeswyk, Rene 9596-0185

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-13 Roofing Material, Roof, Flashing Pitch

Law Library building, roof, from exhaust.

No PLMLaw library, main and annex buildings

12-Jun-96 Chrysotile<1 %

NCRC-10 Roofing Material, Roofing Core Law Library building, roof.

South-west side.

No PLMLaw library, main and annex buildings

12-Jun-96 Chrysotile18 %

NCRC-12 Roofing Material, Roofing Core Law Library building, roof, from northeast side.

No PLMLaw library, main and annex buildings

12-Jun-96 Chrysotile20 %

NCRC-LLT-

Roofing Material, Roofing Core Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile<1 %

NCRC-LLT-

Roofing Material, Roofing Core Trailer: Hallway Roof No PLMAttached Trailer16-Jan-18 Chrysotile<1 %

01 Stucco, white Electrical Rm #2, side B wall N/A PLMElectrical Rooms12-Apr-16 ND

02 Stucco, white Electrical Rm #1, side B wall N/A PLMElectrical Rooms12-Apr-16 ND

03 Stucco, white Patio Area, side B wall N/A PLMPatio Area12-Apr-16 Chrysotile<1 %

04 Stucco, white Exterior, side C wall N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %

05 Stucco, white Exterior, side D wall N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %

06 Stucco, white Exterior, side C eave N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %

07 Stucco, white Exterior, side C eave N/A PLMExterior throughout12-Apr-16 Chrysotile<1 %

NCRC - North Building

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

NE Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

SJ1 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

Thursday, February 5, 2026 Page 8 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

N. Hallway (leading to VPS) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

SJ-5 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

Judge's Library N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

Hallway N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Ceiling Material, 1'x1' Concealed Spline CT

Dept. 5 Hallway N/A PLMThroughout "Old" Courthouse27-Jan-06 ND

VPS-06 Ceiling Material, 1'x1' Glued CT Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

VPS-12 Ceiling Material, 1'x1' Glued CT Detective Squad Room N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-04 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes

Basement: Hallway N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

VPS-21 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes

Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-24 Ceiling Material, 2'x2' CT "Pitted" w/ Pinholes

Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-13 Ceiling Material, 2'x2' CT w/ "Chicken Tracks"

Conference Room N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

NCRC-IT-

Ceiling Material, 2'x2' CT: "Pitted" with Pinholes

Hallway N/A PLMVarious areas throughout facility

26-May-06 ND

VPS-16 Ceiling Material, 2'x2' Lay-in CT w/ "Chicken Tracks"

Seargent Office N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-01 Ceiling Material, 2'x2' Lay-in CT w/ Fissures

Basement: Briefing Rm. N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

VPS-05 Ceiling Material, 2'x2' Lay-in CT w/ Fissures

Basement: Hallway N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

Thursday, February 5, 2026 Page 9 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-OC-

Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes

N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse

20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes

W. Hallway N/A PLMVarious Areas in "Old" Courthouse

20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes

Janitor's Closet N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes

Basement: C03 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Chicken Tracks" w/ Pinholes

Basement: C031 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes

N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse

20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes

Dept. 9 Courtroom N/A PLMVarious Areas in "Old" Courthouse

27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes

Basement: C016 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Fissures" w/ Pinholes

Basement: C015 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

C121 (Hallway) N/A PLMVarious Areas in "Old" Courthouse

20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

N. Hallway (leading to VPS) N/A PLMVarious Areas in "Old" Courthouse

20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Interview Room N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Janitor's Closet N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Basement: C018 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Basement: C011 N/A PLMVarious Areas in Basement27-Jan-06 ND

Thursday, February 5, 2026 Page 10 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Basement: C04 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Basement: C03 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Pitted" w/ Pinholes

Basement: C015 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-

VPS-01

Ceiling Material, 2'x4' CT "Pitted" w/ Pinholes

Squad Room N/A PLMVarious ares of VPS27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

SW Hallway N/A PLMSW Hallway & Copy Room20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Copy Room N/A PLMSW Hallway & Copy Room20-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Family Service Break Room N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Family Service Hallway N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Family Service Mail Room N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Lobby N/A PLMVarious Areas in "Old" Courthouse

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Suite 500 Hallway N/A PLMVarious Areas in "Old" Courthouse

27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Suite 500 Conference Room N/A PLMVarious Areas in "Old" Courthouse

27-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'X4' CT "Sandpaper" Finish

Suite 500 Substance Abuse N/A PLMVarious Areas in "Old" Courthouse

27-Jan-06 ND

VPS-02 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"

Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

VPS-03 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"

Basement: Men's Locker Room N/A PLMVarious ares of VPS/Courthouse

25-Oct-06 ND

Thursday, February 5, 2026 Page 11 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

VPS-10 Ceiling Material, 2'x4' CT w/ "Chicken Tracks"

Detective Squad Room N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

NCRC-OC-

Ceiling Material, 2'x4' Drywall CT S. Men's Restroom N/A PLMS. Restrooms; Family Service Restrooms

23-Jan-06 ND

NCRC-OC-

Ceiling Material, 2'x4' Drywall CT Family Services Men's Restroom

N/A PLMS. Restrooms; Family Service Restrooms

23-Jan-06 ND

NCRC-OC-

Drywall, Drywall SJ1 (Jury Room) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Drywall, Drywall C121 (Hallway) N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Drywall, Drywall W. Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Drywall, Drywall SW Hallway N/A PLMThroughout "Old" Courthouse20-Jan-06 ND

NCRC-OC-

Drywall, Drywall Janitor's Closet N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Family Service Break Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Family Service Hallway N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Family Service Mail Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Lobby N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Interview Room N/A PLMThroughout "Old" Courthouse23-Jan-06 ND

NCRC-OC-

Drywall, Drywall Suite 500 Hallway N/A PLMThroughout "Old" Courthouse27-Jan-06 ND

NCRC-OC-

Drywall, Drywall Suite 500 Conference Room N/A PLMThroughout "Old" Courthouse27-Jan-06 ND

Thursday, February 5, 2026 Page 12 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-OC-

Drywall, Drywall Suite 500 Substance Abuse N/A PLMVarious Areas in "Old" Courthouse

27-Jan-06 ND

NCRC-OC-

Drywall, Drywall Basement: C018 N/A PLMVarious Areas in Basement27-Jan-06 ND

NCRC-OC-

Drywall, Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

NCRC-

VPS-04

Drywall, Drywall Squad Room N/A PLMThroughout Facility27-Jan-06 ND

VPS-14 Drywall, Drywall Conference Room N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-17 Drywall, Drywall Seargent Office N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-20 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-22 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-25 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

VPS-28 Drywall, Drywall Hallway N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

NCRC-OC-

Drywall, Vinyl Drywall C121 (Hallway) N/A PLMC121 (Hallway)20-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement: C04 N/A PLMThroughout Basement27-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement: C03 N/A PLMThroughout Basement27-Jan-06 ND

Thursday, February 5, 2026 Page 13 of 45

ND-None Detected; N/A-Not Applicable; PLM-Polarized Light Microscopy; XRD-X-Ray Diffraction; TEM-Transmission Electron Microscopy; SEM-Scanning Electron Microscopy.

Asbestos Types include: Chrysotile, Amosite, Crocidolite, Actinolite, Tremolite, and Anthophyllite. The detection limit is between 1/10 to 1 percent by area and is dependent on the size of the asbestos fibers and the matrix of the sampled material. Trace - Asbestos was identified in sample; concentration less than quantitation limit of 1%.

Vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods, e.g. XRD, TEM, and SEM, are recommended if greater certainty about asbestos content is required.

Date Collected

Project #:Collected By:

Material Description Friable Analysis Type Asbestos Content and Type

Asbestos Bulk Sample Report Sampling Location:

North County Regional Center

Mark Middlestead 0506-079

Sample Location Material Location

325 S Melrose Drive, Vista

NCRC-OC-

Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

NCRC-OC-

Drywall, Vinyl Drywall Basement Hallway N/A PLMThroughout Basement27-Jan-06 ND

VPS-30 Drywall, Vinyl Drywall Basement: Traffic N/A PLMVarious areas of VPS/Courthouse

25-Oct-06 ND

NCRC-OC-

Floor Covering - Linoleum, Cream-color Linoleum

Basement: C015 (Men's Restroom)

Yes PLMC015 & C01627-Jan-06 Chrysotile10 %

VPS-01 Floor Covering - Misc., Terrazo Sheriff Public Hallway N/A PLMSheriff Public Hallway25-Mar-10 ND

VSS-01 Floor Covering - Tile, 1'x1' Off-white FT

VPS: Room…