This is Solicitation Addendum No. 3 for RFP 1100 LLM3010 issued by the City of Austin Financial Services - Central Procurement on October 29, 2026, establishing clarifications and modifications to the Weather Services and Decision Dashboard contract opportunity. The City of Austin seeks a utility-grade weather forecasting and decision dashboard software solution to support Austin Energy's operational planning and storm response capabilities across its 520,000+ customer service territory. The solution must deliver 24/7/365 access to professional meteorologists, real-time and forecasted weather data, predictive outage models updated hourly, mobile and desktop accessibility, and integration with Austin Energy's Advanced Distribution Management System (Schneider Electric EcoStruxure ADMS version 3.8, upgrading to 3.11 in late Q2 2028). Key requirements include data transmission every 15 minutes, 99.99% availability, and forecasting of anticipated outages within hourly timeframes. The contract term is 24 months for Years 1 and 2, with three optional 12-month renewal periods. Implementation follows an eight-milestone payment schedule with work initiation required within 14 business days of award and project kickoff within 30 days. Proposals were due November 5, 2026 at 2:00 P.M. CST, and all proposals must remain valid for 180 calendar days.
This addendum clarifies that subcontractors' experience and qualifications cannot satisfy the prime contractor's minimum requirements, though subcontractors may be named and their contributions described. Security certifications in FedRAMP, TX-RAMP, ISO/IEC 27000-series, and NIST 800 are mandatory minimum qualifications; AES-256 encryption at minimum is required for data at rest with cloud-native key management or Bring Your Own Key functionality. All staff with access to customer data must be located within the contiguous United States and undergo criminal and financial background checks. The City will conduct penetration testing at no additional cost. The contractor must carry Commercial General Liability, Professional Liability, and Cyber Liability insurance at $2,000,000 minimum per occurrence and aggregate. The addendum specifies that meteorologist support includes on-demand 24/7/365 telephone and email access for up to three authorized callers with allowance for up to three conference calls per day, executive briefings up to 72 hours prior to weather events, and twice-daily briefings during weather events. Evaluation criteria allocate 25 points for Utility Solution Concept and Strategy, 35 points for Experience, 20 points for Price, and up to 10 points each for Local Business Preference (Austin-Round Rock-San Marcos MSA) and Small Business Preference (SBA-certified small businesses or those using small business subcontractors for at least 5% of contract value). No MBE/WBE subcontracting goals apply. An ADMS TEST environment will be made available for integration development and validation. Questions were due October 15, 2026 at 5:00 P.M. CST.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP_1100_LLM3010_ATT_11_v1.pdf | ||
| RFP_1100_LLM3010_ATT_3_v1.pdf | ||
| RFP_1100_LLM3010_ADD_2_v1.pdf | ||
| RFP_1100_LLM3010_ATT_13_v1.pdf | ||
| RFP_1100_LLM3010_ATT_9_v1.docx | DOCX document | |
| RFP_1100_LLM3010_ATT_1_v1.pdf | ||
| RFP_1100_LLM3010_ATT_5_v2.pdf | ||
| RFP_1100_LLM3010_ATT_10_v1.pdf | ||
| RFP_1100_LLM3010_ATT_7_v1.docx | DOCX document | |
| RFP_1100_LLM3010_ATT_1_v4.pdf | ||
| RFP_1100_LLM3010_ATT_2_v1.pdf | ||
| RFP_1100_LLM3010_ATT_4_v1.pdf | ||
| RFP_1100_LLM3010_ATT_5_v1.pdf | ||
| RFP_1100_LLM3010_ATT_12_v1.docx | DOCX document | |
| RFP_1100_LLM3010_ADD_1_v1.pdf | ||
| RFP_1100_LLM3010_ATT_8_v1.xlsx | XLSX spreadsheet | |
| RFP_1100_LLM3010_ATT_6_v1.xlsx | XLSX spreadsheet |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLICITATION ADDENDUM
AUSTIN FINANCIAL SERVICES – CENTRAL PROCUREMENT
Revised 10/01/2024
Solicitation: RFP 1100 LLM3010 Addendum No: 3 Date: 10/29/2026
This addendum is to incorporate the following changes to the above referenced solicitation:
1. QUESTIONS:
SCOPE OF WORK QUESTIONS
1.1. Question: Can a named subcontractor's experience, references and hosting certifications count toward the prime's minimum requirements and experience score?
Answer: No.
1.2. Question: May an offeror satisfy the minimum qualifications, reference requirements, deployed-dashboard benchmark, and scored experience criteria through a named subcontractor or formal teaming partner that will perform the applicable weather forecasting and meteorological services? If so, how will the City attribute and score that experience?
Answer: Subcontractors may be named in the solution offer. A subcontractor's qualifications do not satisfy the Prime's obligation to meet the minimum qualifications. The Prime can state which subcontractors they intend to use and describe how each will contribute to the scope of work.
1.3. Question: If a proposer delivers weather data one way into Austin Energy’s existing systems (e.g., ADMS, ArcGIS) and does not receive, store or host any Austin Energy data, do the certifications in 10.3.1(a) still apply? If so, which ones?
Answer: Yes. FedRAMP, TX-RAMP, ISO/IEC 27000-series certification or equivalent all have requirements that if met will prevent the introduction of malicious code and intrusion by malicious actors.
1.4. Question: Would Austin Energy accept demonstrations of capability as part of the proposal for this project?
Answer: Demonstrations will be requested during a second review tier and not requested or required as part of the initial proposal.
1.5. Question: SOW Section 5.1.15 - Human Capital Staffing Forecasts: Section 5.1.15 states that the solution shall forecast required staffing levels based on predicted weather conditions to support effective and efficient resource allocation. Please clarify the intended scope of this requirement.
Specifically, is Austin Energy seeking:
1.5.1. Q-A. Forecasts of potential outage impacts (e.g., predicted outage counts, customer interruptions, restoration workload, storm response tiers ( (i.e. Tier 2 = 30,000 - 50,000 outages)) or affected customers) to support staffing decisions; If storm response tiers applies, are you willing to share your storm response tier levels?
Answer: The dashboard should contain predictive data showing a range of anticipated outages within hourly timeframes. For example: 1,000 – 5,000 outages expected from 10am-12pm; 5,001 – 7,000 outages expected from 12pm-1pm.
1.5.2. Q-B. Forecasts of service interruptions and operational impacts by geographic area or asset class;
or Answer: The dashboard should contain predictive data showing a range of anticipated outages within hourly timeframes. For example: 1,000 – 5,000 outages expected from 10am-12pm; 5,001 – 7,000 outages expected from 12pm-1pm.
1.5.3. Q-C. Direct recommendations regarding required staffing levels, crew counts, and resource allocation by role and location?
Answer: There is no expectation of the solution providing a direct recommendation of required staffing levels, crew counts, or resource allocation by role and location.
1.5.4. Q-D. Additionally, please indicate any desired forecast outputs, planning horizons, or performance expectations that respondents should consider in their proposed approach. If damage prediction is also of interest and if it influences decision making criteria, please specify.
Answer: Damage prediction is not a requirement for this RFP but may be added to Category 4 of the Price Sheet as desired.
1.6. Question: Solution accessibility calls for access by mobile platform. What is the use case for monitoring weather from a mobile app? Does it require the solution to monitor GPS location? Can you provide scoping numbers of how many employees, and for what roles, will the mobile solution be needed?
Answer: The Energy Control Center supervisor and staff, Emergency Management staff, and other Incident Management Team staff will use the mobile application to receive alerts, log in, assess conditions, and make staffing decisions. This is the equivalent to approximately 40 staff members.
1.7. Question: SOW Section 3 - Current State Overview: Can you provide more information regarding your current state? How are you currently using current and forecasted weather to plan resource needs? Are the requirements in this RFP and upgrade from what you are doing today? If so how are your current weather limitations a challenge for you and what is the expected value and impact from the outcome of this RFP?
Answer: Current weather services are used to determine how many extra field crews are needed and in which part of town they will be staged prior to a weather event. Austin Energy is hoping to build upon its current predictive dashboard by fine-tuning the crews counts and timing.
1.8. Question: Please clarify which security authorizations or certifications are mandatory at proposal submission and contract commencement. Must each proposed hosting environment concurrently maintain FedRAMP, TX-RAMP, ISO/IEC 27000-series certification, and a specific NIST certification or assessment, or may offerors demonstrate equivalent compliance through applicable authorizations and control mappings?
Answer: All proposals will need to meet the minimum qualifications to be considered responsive.
Proposals will then be evaluated and scored based on the information provided within the proposal. Refer to Solicitation Instructions, section 10.3.1 for minimum qualifications.
1.9. Question: Please identify Austin Energy’s ADMS vendor and version, available integration methods or interface specifications, expected data-update frequency, and whether a sandbox will be available.
Please also confirm which historical outage, asset, customer-impact, and weather datasets Austin Energy will provide for model configuration and validation.
Answer: Outage datasets include historic customer outage data: customer address, date, time of outage, time of restoration, outage cause, outage sub-cause, comments.
Austin Energy’s ADMS is operated by Schneider Electric (EcoStruxure ADMS). The current production version is 3.8, and we have initiated an upgrade project to move to version 3.11, tentatively scheduled to go live in late Q2 2028.
The expected data-update frequency is every 15 minutes.
An ADMS TEST environment will be made available for integration development and validation activities.
Refer to Exhibit F – ADMS Integration Methods.
1.10. Question: Please define the required service levels for 24/7 meteorologist access, including acceptable communication channels, response times, briefing frequency, storm-activation procedures, and any required concurrent support capacity during major events.
Answer: On demand 24x7x365 telephone and email access to meteorologists by up to three (3) Authorized callers, plus backups as needed. Conference calls will be governed by the following:
ο An allowance of up to three (3) conference calls per day ο Calls should be scheduled and facilitated at the control center or headquarters level only ο Briefing frequency pre-weather event: up to 72-hours prior to the start of a weather event, provide an executive briefing to include timing and type of expected weather conditions via a presentation deck ο Briefing frequency during weather event: provide morning and evening briefings using same format as the pre-weather event briefing. Continue twice daily briefings unless otherwise directed by the Energy Control Center or Emergency Management point of contact.
2. CHANGES:
2.1. The Solicitation Cover Sheet has been updated to reflect:
2.1.1. Version (Addenda) 3
2.2. The Solicitation Scope of Work has been updated to reflect:
2.2.1. Section 5.1.3, incorporating Exhibit F
2.3. Added Exhibit F – ADMS Integration Methods
3. ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME.
ACKNOWLEDGED BY:
Offeror Name Offeror Authorized Signature Date
RETURN ONE COPY OF THIS ADDENDUM WITH YOUR RESPONSE PRIOR TO THE SOLICITATION CLOSING
DATE. FAILURE TO DO SO MAY CONSTITUTE GROUNDS FOR REJECTION OF YOUR OFFER.
Solicitation: RFP 1100 LLM3010 Addendum No: 3 Date: 10/29/2026