About this file

This file consists of technical drawings prepared by Pierce Engineering, P.C. for a window replacement project at Beck's Historic Hotel located at 3302 Main Street in Mexico, New York 13114. The project involves the replacement of windows at a historic property with the requirement to maintain the original architectural character and appearance. Specifically, the scope includes replacing thirteen first-floor wood, single-pane, single-hung windows while preserving their original style, appearance, character, and molding profiles; replacing fifteen second-floor vinyl windows that were previously installed inauthentic to the original design to match the new first-floor windows; and replacing four first-floor multiple opening window assemblies. The drawings, prepared as of June 26, 2026, are sealed by New York-licensed engineer Richard Pierce (License No. COA 0019839, expiration 6/30/2028) and include exterior elevations, window detail specifications, vertical sections with precise molding dimensions, and photographic references of existing conditions. All second-floor window rough openings are approximately the same size as first-floor openings, allowing for standardized replacement specifications.

The drawings specify that new windows must replicate the appearance of original windows including molding, with the owner responsible for providing proposed replacement window specifications for approval, including manufacturer details, materials, elevations, horizontal and vertical sections, and exterior decorative molding profiles. The project maintains existing stone sills and decorative molding on head and side jambs only, with new windows featuring decorative pane molding and specified rail and stile widths detailed in the technical specifications. The Request for Proposals indicates SDVOB contracting goals of 66 percent and total MWBE goals of 30 percent, with no previous identical or substantially similar contracts awarded within the past five years.

View the file

Other files

File Type Posted
RFP # 10 Drawings (Windows).pdf PDF
RFP #10 WINDOWS.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING

A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION

OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"

PROJECT NO:

DATE:

SCALE: AS SHOWN

REVISIONS

MARK DATE DESCRIPTION

M

EX

IC

O

, N

EW

Y O

R K

LA

KE

O N

TA

R

IO

R

E H

O

LD

C O

, L

LC

BE

C

K' S

H

IS

TO

R

IC

H

O

TE

L

M

AI

N

S

TR

EE

T

06/26/2026

AutoCAD SHX Text Pierce Engineering, P.C.

AutoCAD SHX Text 3975 Amber Road Syracuse, New York 13215 Tel (315) 492-3688 Email richard@pierceengineeringpc.com

AutoCAD SHX Text License expiration date: 6/30/2028

AutoCAD SHX Text

COA 0019839

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

ELEVATIONS

AutoCAD SHX Text

AutoCAD SHX Text

WEST ELEVATION (LOOKING EAST)

AutoCAD SHX Text A1

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

SOUTH ELEVATION (LOOKING NORTH)

AutoCAD SHX Text A2

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text NOTES: 1. EXISTING THIRTEEN (13) FIRST FLOOR WINDOWS ARE WOOD, SINGLE PANE, SINGLE HUNG. OWNER TO REPLACE THESE WINDOWS (AND EXTERIOR MOLDING AS REQUIRED) WITH UPDATED WINDOWS, BUT KEEP THE STYLE, APPEARANCE, CHARACTER, AND WINDOW MOLDING OF THE EXISTING ORIGINAL WINDOWS. 2. FIFTEEN (15) SECOND FLOOR WINDOWS WERE REPLACED WITH VINYL WINDOWS THAT ARE NOT AUTHENTIC TO THE ORIGINAL WINDOWS. OWNER WILL REPLACE WINDOWS (AND EXTERIOR MOLDING AS REQUIRED) TO MATCH NEW FIRST FLOOR WINDOWS. 3. SECOND FLOOR WINDOW ROUGH OPENINGS ARE APPROXIMATELY SAME SIZE AS THE FIRST FLOOR WINDOW ROUGH OPENINGS. 4. NEW WINDOWS SHALL REPLICATE THE APPEARANCE OF THE ORIGINAL WINDOWS, INCLUDING MOLDING. OWNER SHALL PROVIDE PROPOSED NEW WINDOW REPLACEMENT SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO MANUFACTURER, MATERIAL, ELEVATIONS, HORIZONTAL AND VERTICAL SECTIONS FOR APPROVAL.

AutoCAD SHX Text

(9) FIRST FLOOR WINDOWS, TO BE REPLACED

AutoCAD SHX Text

(9) SECOND FLOOR WINDOWS, TO BE REPLACED

AutoCAD SHX Text

(4) FIRST FLOOR WINDOWS, TO BE REPLACED

AutoCAD SHX Text

(6) SECOND FLOOR WINDOWS, TO BE REPLACED

AutoCAD SHX Text

MULTIPLE OPENING WINDOW ASSEMBLY, SEE SHEET 3 OF 3

OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"

PROJECT NO:

DATE:

SCALE: AS SHOWN

REVISIONS

MARK DATE DESCRIPTION

M

EX

IC

O

, N

EW

Y O

R K

LA

KE

O N

TA

R

IO

R

E H

O

LD

C O

, L

LC

BE

C

K' S

H

IS

TO

R

IC

H

O

TE

L

M

AI

N

S

TR

EE

T

06/26/2026

AutoCAD SHX Text Pierce Engineering, P.C.

AutoCAD SHX Text 3975 Amber Road Syracuse, New York 13215 Tel (315) 492-3688 Email richard@pierceengineeringpc.com

AutoCAD SHX Text License expiration date: 6/30/2028

AutoCAD SHX Text

COA 0019839

AutoCAD SHX Text

WINDOW

AutoCAD SHX Text

ELEVATIONS

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

2X STUD (TYP.)

AutoCAD SHX Text

TYPICAL FIRST FLOOR SINGLE HUNG WINDOW DETAILS

AutoCAD SHX Text A1

AutoCAD SHX Text

SCALE: AS NOTED

AutoCAD SHX Text

WINDOW OPENING

AutoCAD SHX Text

FINISH FLOOR

AutoCAD SHX Text

INTERIOR VIEW - WINDOW FRAME ELEVATION

AutoCAD SHX Text

INTERIOR VIEW - WINDOW ELEVATION

AutoCAD SHX Text

1 " WIDE SIDE STILES18" WIDE SIDE STILES

AutoCAD SHX Text

FIXED

AutoCAD SHX Text

OPENABLE

AutoCAD SHX Text

1 " WIDE SIDE STILES18" WIDE SIDE STILES

AutoCAD SHX Text

2 " WIDE BOTTOM RAIL78" WIDE BOTTOM RAIL

AutoCAD SHX Text

1 " WIDE TOP RAIL12" WIDE TOP RAIL

AutoCAD SHX Text

1 " WIDE18" WIDE

AutoCAD SHX Text

EXTERIOR WINDOW DECORATIVE MOLDING PROFILE (HEAD AND SIDE JAMBS ONLY)

AutoCAD SHX Text

TYPICAL FIRST FLOOR SINGLE HUNG WINDOW VERTICAL SECTION

AutoCAD SHX Text A2

AutoCAD SHX Text

SCALE: 1-1/2" = 1'-0"

AutoCAD SHX Text

DECORATIVE MOLDING HEAD AND SIDE JAMBS ONLY

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text

FIXED

AutoCAD SHX Text

OPENABLE

AutoCAD SHX Text

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text

SCALE: 6" = 1'-0"

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

STONE SILL TO REMAIN

AutoCAD SHX Text

DECORATIVE PANE MOLDING, ALL AROUND

AutoCAD SHX Text

WINDOW GLASS

AutoCAD SHX Text

WINDOW RAIL / STILE

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text

BRICK

AutoCAD SHX Text

DECORATIVE MOLDING

AutoCAD SHX Text

BRICK

AutoCAD SHX Text

DECORATIVE MOLDING

AutoCAD SHX Text

TYPICAL FIRST FLOOR WINDOW PHOTOS

AutoCAD SHX Text A3

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

INTERIOR VIEW

AutoCAD SHX Text

EXTERIOR VIEW - SILL / SIDE JAMB

AutoCAD SHX Text

EXTERIOR VIEW - SIDE JAMB / HEAD

NOTE: SECOND FLOOR WINDOWS WERE REPLACED WITH VINYL WINDOWS THAT ARE NOT AUTHENTIC TO THE ORIGINAL WINDOWS. OWNER WILL REPLACE SECOND FLOOR WINDOWS (AND EXTERIOR MOLDING AS REQUIRED) TO MATCH NEW FIRST FLOOR WINDOWS. SECOND FLOOR WINDOW ROUGH OPENINGS ARE APPROXIMATELY THE SAME SIZE AS THE FIRST FLOOR WINDOW ROUGH OPENINGS.

OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"

PROJECT NO:

DATE:

SCALE: AS SHOWN

REVISIONS

MARK DATE DESCRIPTION

M

EX

IC

O

, N

EW

Y O

R K

LA

KE

O N

TA

R

IO

R

E H

O

LD

C O

, L

LC

BE

C

K' S

H

IS

TO

R

IC

H

O

TE

L

M

AI

N

S

TR

EE

T

06/26/2026

AutoCAD SHX Text Pierce Engineering, P.C.

AutoCAD SHX Text 3975 Amber Road Syracuse, New York 13215 Tel (315) 492-3688 Email richard@pierceengineeringpc.com

AutoCAD SHX Text License expiration date: 6/30/2028

AutoCAD SHX Text

COA 0019839

AutoCAD SHX Text

WINDOW

AutoCAD SHX Text

ELEVATIONS

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

FIRST FLOOR MULTIPLE OPENING WINDOW ASSEMBLY

AutoCAD SHX Text A1

AutoCAD SHX Text

SCALE: AS NOTED

AutoCAD SHX Text

EXTERIOR VIEW - WINDOW ELEVATION

AutoCAD SHX Text

EXTERIOR VIEW - REMOVABLE WINDOW ELEVATION

AutoCAD SHX Text

SCALE: 3/4" = 1'-0"

AutoCAD SHX Text

SCALE: 3/4" = 1'-0"

AutoCAD SHX Text

DECORATIVE MOLDING TO REMAIN, HEAD AND SIDE JAMBS ONLY

AutoCAD SHX Text

DECORATIVE MOLDING TO REMAIN, HEAD AND SIDE JAMBS ONLY

AutoCAD SHX Text

STONE SILL TO REMAIN

AutoCAD SHX Text

DECORATIVE MOLDING TO REMAIN, HEAD AND SIDE JAMBS ONLY

AutoCAD SHX Text

2"± WIDE SIDE STILES

AutoCAD SHX Text

1 " WIDE SIDE STILES12"± WIDE SIDE STILES

AutoCAD SHX Text

2 " WIDE BOTTOM RAIL34" WIDE BOTTOM RAIL

AutoCAD SHX Text

1 " WIDE TOP RAIL12"± WIDE TOP RAIL

AutoCAD SHX Text

18"D X 1"WIDE

AutoCAD SHX Text

WINDOW MOLDING - SECTION

AutoCAD SHX Text

SCALE: 1" = 1"

AutoCAD SHX Text

WINDOW RAILS / STILES

AutoCAD SHX Text

WINDOW PANE

AutoCAD SHX Text

CAULK

AutoCAD SHX Text

MOLDING, ALL AROUND

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text

(4) REMOVABLE WOOD WINDOW, TO BE REPLACED

AutoCAD SHX Text

MOLDING

AutoCAD SHX Text NOTES: 1. WINDOW ASSEMBLY: FRAME, MULLIONS, INTERIOR CASEMENT WINDOWS, INTERIOR HOPPER WINDOWS, AND EXTERIOR MOLDING TO REMAIN. 2. ONLY (4) EXTERIOR WINDOW ASSEMBLIES SHALL BE REPLACED. 3. WINDOW EXTERIOR DECORATIVE MOLDING HAS SAME PROFILE AS FIRST FLOOR SINGLE HUNG WINDOW MOLDING. SEE SHEET 1 OF 3, DETAIL A1, WINDOW - EXTERIOR DECORATIVE MOLDING PROFILE.

AutoCAD SHX Text A3

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

EXTERIOR VIEW

AutoCAD SHX Text

FIRST FLOOR MULTIPLE OPENING WINDOW ASSEMBLY - PHOTOS

AutoCAD SHX Text

WINDOW MULLIONS TO REMAIN

AutoCAD SHX Text

TYPICAL FIRST FLOOR SINGLE HUNG WINDOW VERTICAL SECTION

AutoCAD SHX Text A2

AutoCAD SHX Text

SCALE: 1-1/2" = 1'-0"

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text

BRICK

AutoCAD SHX Text

DECORATIVE MOLDING

AutoCAD SHX Text

(4) REMOVABLE WOOD WINDOW ASSEMBLIES, TO BE REPLACED

AutoCAD SHX Text

HOPPER WINDOWS TO REMAIN

AutoCAD SHX Text

CASEMENT WINDOWS TO REMAIN

AutoCAD SHX Text

DECORATIVE MOLDING

INTERIOR VIEW

Sheets and Views
BECKS HOTEL- WINDOWS-1 OF 3
BECKS HOTEL- WINDOWS-2 OF 3
BECKS HOTEL- WINDOWS-3 OF 3