This Request for Information (RFI) seeks expressions of interest in providing electronics cabinets and rack-mounted solutions for the Electron Ion Collider project at Brookhaven National Laboratory. The laboratory requires approximately 900 cabinets over five years, with varying configurations for cooling methodology including heat exchanger cooled, fan cooled ambient air, and directed ducted forced air supply. Cabinets must maintain an internal temperature of 75 degrees Fahrenheit, support lifting of 400 kilograms or more, and have dimensions between 24 to 31.5 inches wide and 36 to 48 inches deep. Respondents are asked to describe their capabilities and experience in producing such cabinets, minimum order quantities, lead times, ability to provide computational fluid dynamics analysis, and whether manufacturing capabilities are located in the United States. Budgetary pricing should be provided based on quantity options listed in the document. Electronic responses are due to Cindy Blanchard by the contact information provided by the deadline not specified in this RFI.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
March 18, 2024
Request for Information (RFI)/Sources Sought
No. 03182024-CAB Electronics Cabinets/Racks
To all Potential/Interested Suppliers, Brookhaven Science Associates, LLC (herein known as “BSA”), operator of Brookhaven National Laboratory (BNL) under a Prime Contract with the U.S. Department of Energy (DOE), is seeking expressions of interest from firms regarding Electronics Cabinets and Rack mounted solutions as outlined in Attachment A – Specification for Electronics Cabinets and Racks.
Please note that this is an RFI/Sources Sought notice, not a Request for Proposal, and no solicitation exists at this time.
This RFI is for informational and planning purposes only and is not to be construed as a commitment by the U.S. Government, nor will the U.S. Government pay for information received. The information from this notice will help the Department of Energy (DOE) Office of Basic Energy Sciences (BES) survey available resources.
The Electron Ion Collider (EIC) is a new Nuclear Physics Facility that will use collisions between polarized ions and polarized electrons to study the inner structure of the Nucleon.
Please provide the following information:
1) Does your company have the capabilities and past experience in producing Electronics Cabinets and Rack mounted solutions as noted in Attachment (A), Specification for Electronics Cabinets and Rack mounted solutions within the past 5 years?
2) What is the minimum order quantity? What is the lead time?
3) Does your company have the capabilities to provide Computational Fluid Dynamics (CFD) analysis of BNL rack configurations?
4) Does your company have manufacturing, assembly, testing capabilities and available resources to meet the proposed schedule constraints?
5) Does your company have manufacturing capabilities in the US?
We are open to all information you can and care to provide at this point.
BSA prefers electronic submissions of submittals. Electronic submissions will be accepted by the following method:
• Email submissions should express your interest and describe your capabilities related to delivering this product. Emails shall be sent Cindy Blanchard at cblanchar@bnl.gov.
mailto:cblanchar@bnl.gov
We trust that the information contained herein is sufficient to permit your company to prepare a submittal outlining:
1) your capabilities
2) estimated lead times
3) budgetary pricing based on the quantity options listed in the Section 7 Table.
However, should you have any questions, please contact the undersigned.
Sincerely, Cindy Blanchard
Cindy Blanchard Contracts Specialist I Procurement & Property Management Division Brookhaven National Laboratory Upton, New York 11973 Phone: (631) 344-5770 Email: cblanchar@bnl.gov mailto:cblanchar@bnl.gov
Attachment A Specifications for Electronics Cabinets and Racks
Dated: March 18, 2024
1. Overview
1.1 Current Estimated Qty of Approximately 900 Cabinets.
1.2 Procured over an estimated 5-year period, 2026-2031.
1.3 BSA could potentially award one or multiple awardees at time of competitive solicitation.
1.4 BNL is currently evaluating 3 different cooling methodologies for the varying applications required to support the EIC project.
1.4.1 Heat Exchanger (HX) Cooled. This is a sealed rack with a water-to-air heat exchanger inside it which circulates air in a closed loop. The general design is that the HX blows cool air to front plenum created by the front door, sides, and chassis front panels. Air flows from the front through chassis (or between chassis) to the heat exchanger return.
1.4.2 Fan cooled ambient air. This is a rack with no heat exchanger, where fans direct cool, filtered ambient air from outside into the cabinet, and/or hot air from inside the rack to the outside.
1.4.3 Directed/Ducted forced air supply. This is a rack with no heat exchanger, where a source of cooled air is forced directly into the cabinet from ducting entering the lower side of the cabinet.
1.5 It is expected at time of final design, that racks will have varying overall dimensions for rack, doors, and rack base. Racks will also have the differing penetration requirements, depending on the cooling method, and cable access needs, these penetrations will either have blank panels, fans, filters, or other modifications to allow for cable access, AC delivery, or water fittings.
1.6 Where appropriate in your responses, please include assumptions for rack inputs (chilled water temperature, ambient air temperature, ducted/forced air temperature and flow rate, etc.)
1.7 BNL recognizes these unknowns will influence final pricing but is under the assumption that a sufficient budgetary quote can still be estimated by the supply base.
2. Standards
2.1 The standards listed below shall be used for the design of the specified equipment.
2.1.1 NFPA 70 National Electric Code (Latest Edition)
2.1.2 UL 1995 Heating and Cooling Equipment
2.1.3 UL 50 Cabinets and Boxes
2.1.4 NRTL Listed
3. General Design Specifications of Rack Enclosures
3.1 The proposed rack solutions shall be capable of maintaining a constant internal temperature of 75F +/- 3 degrees. The nominal expected building/ambient provided air temperature range is currently 68-75F +/-3 degrees.
3.2 The cooling system shall be designed such that cooling is delivered and heat is removed to maintain even temperature throughout the loaded rack.
3.3 All enclosure panels including doors, sidewalls, and topsides shall be directly connected to the frame.
3.4 Racks shall have removable side panels.
3.5 Mounting provisions shall allow for multiple racks to be bolted together in a side-by-side fashion.
3.6 Racks shall have gasketed front and rear doors.
3.7 The rack shall have 52 U (U=1-3/4”) available for front panels of mounted equipment. See Dimensional Table below for request varying options to evaluate.
3.8 The cabinets shall have a minimum width of 24 inches (±1/2 inch) and a maximum width of 31.5 inches (+/-1/2 inch) depending on the configuration option. See Pricing Table below for varying options to evaluate.
3.9 The internal racks shall have standard "U" rails configured to accept 19-inch equipment via
10-32 tapped holes in standard U spacing.
3.10 All rack solutions shall have adjustable front, middle and rear rails.
3.11 The rack shall have a maximum depth of either 36 inches (±1/8 inch) or 48 inches depending on the configuration. See Dimensional Table below for request varying options to evaluate.
3.12 Door latches are key lockable, but capable of being opened without using a key when unlocked.
3.13 All rack components shall be electrically bonded together. Grounding studs and a grounding busbar will be provided.
3.14 Racks shall have lifting points on the top of the rack to allow the attachment of rated hoist rings and shall be sufficient to accommodate lifting and transport in the fully loaded condition.
3.15 Rack and rack base shall be fork liftable.
4. Heat Exchanger Cooled Design Specifications
4.1 The heat exchanger shall be water-cooled.
4.2 The water-cooled heat exchanger will meet the standards for NEMA12 performance per UL50 at the interface between the heat exchanger and the rack group being cooled. It shall be UL Listed, labeled, and marked as such.
4.3 The heat exchanger shall be capable of removing either 5KWs or 10KWs of heat depending on the configuration.
4.4 The heat exchanger cabinet solution shall have an integrated temperature sensor that provides feedback to the cooling source for dynamic adjustments.
4.5 The heat exchanger shall have a blower or impeller at the front, which directs the air up along the front door of the cabinet.
4.6 The blower or impeller shall be capable of providing a flow rate of 1000cfm.
4.7 Rack mounted equipment will pull the cool air through the chassis and exhaust the warm air to the rear of the cabinet.
4.8 The heat exchanger shall pull the warm air down and re-circulate the conditioned air to the front of the cabinet.
4.9 The water supply and return connection fittings shall be supplied as the last connection before entering the rack for easy disconnection and access inside the rack. Supply and return shall have manual shutoff valves for service.
4.10 Any water control valves shall be inboard to the rack enclosure.
4.11 All racks will be fully gasketed for tight, leak-proof installation in compliance with
NEMA12 Enclosure Rating and UL 50 and marked as such.
4.12 The door construction shall be in compliance with NEMA 12 standards, meeting deflection and resistance to dust and dripping liquids requirements per the UL 50 Standard.
4.13 The rack structure shall be capable of supporting a minimum of 400kgs of BNL furnished equipment.
5. Fan Cooled Ambient Air Design Specifications
5.1 The racks shall have filters to allow ambient air into the cabinets.
5.2 Cabinets shall have necessary filtering provisions to allow for clean continuous operation.
5.3 The rack shall have an opening at the bottom of the cabinet for cool air entry.
5.4 The heat exchanger shall have a blower or impeller at the front, which directs the air up
5.5 The blower or impeller shall be capable of providing a flow rate of 1000cfm.
5.6 The racks shall have fan(s) to blow warm air exiting the rear of the rack mounted chassis units out of the top of the cabinet.
5.7 The cabinet air flow design shall be capable of removing up to 5KWs of heat.
5.8 The rack structure shall be capable of supporting a minimum of 200kgs of BNL furnished
6. Directed/Ducted Air Design Specifications
6.1 The rack shall have an opening at the lower side of the cabinet for cool air entry.
6.2 The heat exchanger shall have a blower or impeller at the front, which directs the air up
6.3 The blower or impeller shall be capable of providing a flow rate of 1000cfm.
6.4 The racks shall have fan(s) to blow warm air exiting the rear of the rack mounted chassis units out of the top of the cabinet.
6.5 The cabinet air flow design shall be capable of removing either 5KWs or 10KWs of heat depending on the configuration.
6.6 The rack structure shall be capable of supporting a minimum of 400kgs of BNL furnished
7. Table of Options – Budgetary Pricing
Configuration Description Qty. 25 Qty. 50 Qty. 100 Qty. 250 Qty. 500 Heat Exchanged Configurations 5KW, Heat Exchanged, 24” Width, 36” Depth 10KW, Heat Exchanged, 24” Width, 36” Depth 5KW, Heat Exchanged, 24” Width, 48” Depth 10KW, Heat Exchanged, 24” Width, 48” Depth 5KW, Heat Exchanged, 31.5” Width, 36” Depth 10KW, Heat Exchanged, 31.5” Width, 36” Depth 5KW, Heat Exchanged, 31.5” Width, 48” Depth 10KW, Heat Exchanged, 31.5” Width, 48” Depth Fan Cooled Ambient Air Configurations 5KW, Fan Cooled Ambient Air, 24” Width, 36” Depth 5KW, Fan Cooled Ambient Air, 24” Width, 48” Depth 5KW, Fan Cooled Ambient Air, 31.5” Width, 36” Depth 5KW, Fan Cooled Ambient Air, 31.5” Width, 48” Depth Directed/Ducted Air Configurations 5KW, Ducted Air, 24” Width, 36” Depth 10KW, Ducted Air, 24” Width, 36” Depth 5KW, Ducted Air, 24” Width, 48” Depth 10KW, Ducted Air, 24” Width, 48” Depth 5KW, Ducted Air, 31.5” Width, 36” Depth 10KW, Ducted Air, 31.5” Width, 36” Depth 5KW, Ducted Air, 31.5” Width, 48” Depth 10KW, Ducted Air, 31.5” Width, 48” Depth
*Where possible, please itemize options that are significant cost drivers.
| Request for Information (RFI)/Sources Sought |
| No. 03182024-CAB |
| Electronics Cabinets/Racks |
| Attachment A |
| Specifications for Electronics Cabinets and Racks |
| Dated: March 18, 2024 |
| 1. Overview |
| 2. Standards |