RFC_CR_399_Culvert_Plans_updated_9.26.24.pdf
PDF 20 MB Posted
- Attached to
- GRIFFIN ROAD EAST LANDSCAPE IMPROVEMENTS
- Solicitation number
- 25-006
- Issued by
- Santa Rosa County, Florida
About this file
These construction plans detail the County Road 399/East Bay Boulevard Culvert Replacement project for Santa Rosa County, Florida, prepared by Volkert Engineering. The project involves replacing four culverts (CD-1, CD-4, CD-7, and CD-9) along East Bay Boulevard, with a total project length of 405 linear feet. The culverts are located between US 98 and Koppel Drive, with specific stations ranging from 125+72.05 to 126+72.05, 203+29.76 to 204+34.84, 229+30.94 to 230+30.94, and 243+38.55 to 244+38.55. The project is part of a FEMA contract (No. 21.006-VOL-004-TO#16) and includes full roadway reconstruction, drainage improvements, and utility protection.
The construction plans provide comprehensive details including typical road sections, temporary traffic control strategies, erosion and sediment control measures, and specific technical specifications for culvert replacement. The project involves removing existing culverts, installing new reinforced concrete pipe (RCP) culverts with headwalls, and reconstructing approximately 405 linear feet of roadway with 6" graded aggregate base and 2" asphaltic concrete surface. The plans indicate minimal wetland impacts totaling approximately 1,263 square feet across the four culvert locations. The project includes provisions for utility protection, with existing water lines, gas lines, and other utilities to remain in place during construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| GRIFFIN_ROAD_EAST_LANDSCAPE_IMPROVEMENTS_(Addendum_#1_Revision).pdf | ||
| DRAFT_Construction_Agreement_.docx | DOCX document | |
| FDOT_Spec_580.pdf | ||
| SR_818_GRIFFIN_RD_EAST_LANDSCAPE_PLAN.pdf | ||
| FDOT_Std_Plan_580-001.pdf | ||
| PAYMENT_BOND.pdf | ||
| PERFORMANCE_BOND.pdf | ||
| draft_contract.pdf | ||
| East_Bay_Blvd._Drainage_Phase_II.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLANS PREPARED BY:
CONSTRUCTION PLANS FOR
SANTA ROSA COUNTY CR 399/EAST BAY BLVD CULVERT REPLACEMENT
VOLKERT PROJECT NO. 1195300
CR 399/EAST BAY BLVLD FROM US 98 TO KOPPEL DRIVE
CULVERT CD-1- STA. 125+72.05 - 126+72.05
PROJECT LENGTH= 100.00 LF
CULVERT CD-4- STA. 203+29.76 - 204+34.84
PROJECT LENGTH= 105.08 LF
CULVERT CD-7- STA. 229+30.94 - 230+30.94
PROJECT LENGTH= 100.00 LF
CULVERT CD-9- STA. 243+38.55 - 244+38.55
PROJECT LENGTH= 100.00 LF
OVERALL PROJECT LENGTH- 405 LF
14-16 17-21 22-23
KEY SHEET
GENERAL NOTES
SUMMARY OF QUANTITIES
TYPICAL SECTIONS
PROJECT LOCATION MAP
EXISTING/DEMOLITION PLAN VIEW - CD-1
PROPOSED CULVERT PLAN VIEW - CD-1
EXISTING/DEMOLITION PLAN VIEW - CD-4
PROPOSED CULVERT PLAN VIEW - CD-4
EXISTING/DEMOLITION PLAN VIEW - CD-7
PROPOSED CULVERT PLAN VIEW - CD-7
EXISTING/DEMOLITION PLAN VIEW - CD-9
PROPOSED CULVERT PLAN VIEW - CD-9
CONSTRUCTION DETAIL SHEETS
TEMPORARY TRAFFIC CONTROL SHEETS
SWPP PLAN SHEETS
SHEET NO. SHEET DESCRIPTION
UTILITY WARNING NOTE: THE LOCATION SHOWN FOR EXISTING ABOVE GROUND
AND UNDERGROUD UTILITES IS APPROXIMATE ONLY. THE CONTRACTOR SHALL
ALL UTILITY OWNERS 48 HOURS PRIOR TO ANY CONSTRUCTION TO HAVE LINES
MARKED AND TO DETERMINE EXACT LOCATIONS.
APPLICABLE STANDARDS AND SPECIFICATIONS:
1- FLORIDA DEPARTMENT OF TRANSPORTATION, FY 2021-2022 DESIGN STANDARDS
eBOOK (DSeB) AND APPLICABLE DESIGN STANDARDS REVISIONS (DSRs) AT THE
FOLLOWING WEBSITE:
HTTPS://WWW.FDOT.GOV/DESIGN/STANDARDPLANS/CURRENT/DEFAULT.SHTM
2- MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION, AND
MAINTENANCE FOR STREETS AND HIGHWAYS, FLORIDA DEPARTMENT OF
TRANSPORTATION, FLORIDA GREEN BOOK (2018)
3- DIVISIONS II AND III, AS AMENDED BY CONTRACT DOCUMENTS, OF THE
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AVAILABLE AT THE
FOLLOWING WEBSITE:
HTTP://WWW.FDOT/GOV/PROGRAMMANAGEMENT/IMPLEMENTED/SPECBOOKS
4- AASHTO, GUIDE FOR PLANNING, DESIGN AND OPERATION OF PEDESTRIAN
FACILITIES (2004)
5- ADA STANDARDS (CURRENT)
6- SANTA ROSA COUNTY STANDARDS (CURRENT)
CR 399/EAST BAY BLVD CD-4
STA 203+89.43
CR 399/EAST BAY BLVD END PROJECT
STA 339+74.49
CR 399/EAST BAY BLVD CD-9
STA 243+89.57
CR 399/EAST BAY BLVD CD-1
STA 126+22.83
CR 399/EAST BAY BLVD CD-7
STA 229+82.92
PREPARED FOR:
SANTA ROSA COUNTY
INDEX OF PLANS
100% PLANS - RELEASED FOR CONSTRUCTION
JOHN STUDSTILL, P.E.
CR 399/EAST BAY BLVD START PROJECT
STA 100+00.00
N
PROJECT LOCATION
https://goo.gl/maps/ZUWJNEJFnkB4Yt7U6
EXPRESSWAY
TURNPIKE
PENSACOLA FORT WALTON
BEACH
PANAMA
CITY
BEACH
CHIPLEY
TALLAHASSEE
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND 4
NEW PORT RICHEY
TAMPA
75 4
LAKELAND
MELBOURNE -
COCOA
ORLANDO
BARTOWST PETERSBURG
SARASOTA -
BRADENTON
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
NAPLES
KEY WEST
LAKE
CITY
FLORIDA'S
BEACH LINE
SANTA ROSA COUNTY
PROJECT MANAGER
JOHN STUDSTILL, P.E.
SANTA ROSA COUNTY
6051 OLD BAGDAD HIGHWAY, SUITE 300
MILTON, FL 32583
(850)981-7100
FEMA CONTRACT NO. 21.006-VOL-004-TO#16
STATE OF
No 64091
PR
O
FESSIONAL ENGIN
EE
R
Mi ke
J. Warnke
FLORIDA
AutoCAD SHX Text
D9 DESIGN
AutoCAD SHX Text J.V.
AutoCAD SHX Text 5/7/85
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
REGISTRATION NO.
AutoCAD SHX Text Engineers Surveyors Planners
AutoCAD SHX Text www.volkert.com
AutoCAD SHX Text
215 FAIRPOINT DR. SUITE B
AutoCAD SHX Text Telephone (251) 342-1070
AutoCAD SHX Text
GULF BREEZE, FL. 32561
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
G
EN
ER
A
L N
O
TE
S
STORMWATER NOTES
1. ALL EXISTING DRAINAGE STRUCTURES TO REMAIN UNLESS NOTED TO BE REMOVED.
2. FOR ALL PIPES LOCATED UNDER STREETS, BACKFILL SHALL BE IN 6" LIFTS, WITH DENSITY TESTING REQUIRED EVERY 2 VERTICAL FEET UP TO THE BOTTOM OF THE SUBGRADE. DENSITY IS TO
BE A MINIMUM OF 95% PER ASSHTO T180.
3. ALL PIPE JOINTS MUST BE WRAPPED WITH WOVEN FILTER CLOTH. COST FOR FILTER CLOTH SHALL
BE INCLUDED IN THE COST OF THE PIPE.
4. EXISTING PIPE CONNECTIONS TO STRUCTURES MUST INCLUDE CONCRETE COLLARS PER FDOT STANDARD PLANS INDEX 430-001, PG 4. COST FOR CONCRETE COLLAR SHALL BE INCLUDED IN THE
COST OF THE STRUCTURE.
5. CONTRACTOR SHALL PROVIDE S.W.P.P.P. PREPARED BY THE CONTRACTOR OR CONTRACTOR'S AGENT
PRIOR TO MOBILIZATION.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL TEMPORARY EROSION CONTROL MEASURES AS REQUIRED TO ENSURE NO SEDIMENTS ARE TRANSPORTED OFF-SITE VIA STORMWATER RUN-OFF.
7. ALL SIDE SLOPES AND EMBANKMENTS SHALL BE SODDED AND PINNED WITH GRASS WHICH IS
FREE FROM NOXIOUS WEEDS.
8. CONTRACTOR SHALL CLEAN OUT ACCUMULATED SILT IN BASINS, ROADS, AND THE PIPES AND CHANNELS AT THE END OF CONSTRUCTION WHEN ALL DISTURBED AREAS HAVE BEEN STABILIZED.
9. AREAS CONTAINING. BLOCK SOD SHALL BE PINNED.
10. ON ALL CLEARED AREAS WHICH WILL NOT HAVE ACTIVE CONSTRUCTION UNDERTAKEN FOR A
PERIOD OF 90 DAYS OR MORE, A GROUND COVER SHALL BE PLANTED OR OTHER FORMS OF
STABILIZATION UTILIZED WITHIN 10 WORKING DAYS.
11. ALL PROPOSED UTILITY/INGRESS/EGRESS EASEMENTS MUST BE SHOWN ON THE DRAWING AND MUST
HAVE THE ASSOCIATED LEGAL DESCRIPTION WRITTEN.
12. EDGE-OF-PAVEMENT, ROADS (ASPHALT SHADED), CURBS, DRIVEWAY CONNECTIONS, BUILDINGS, PARKING LOTS, RIGHT-OF-WAY, AND STREET NAMES MUST BE SHOWN IN ALL APPLICATIONS. ALL ITEMS
MENTIONED ABOVE MUST BE FIELD LOCATED.
13. PROPERTY BOUNDARY MUST BE CLEARLY LABELED AND DIMENSIONED. CONTRACTOR MAY RELY UPON
THE BOUNDARY INFORMATION PROVIDED IN THE PLANS.
14. INVERTS, GRATES, TOPS, RIMS MUST BE SHOWN FOR ALL STORM WATER DRAINAGE STRUCTURES.
INVERTS (PIPES AND CLEANOUTS) AND RIMS MUST BE SHOWN FOR ALL GRAVITY SEWER MANHOLES.
SLOPES MUST BE SHOWN ON EACH RUN OF PIPE FOR REVIEW AND APPROVAL.
15. ELEVATIONS AND LOCATION OF ANY FLOOD ZONES ALONG THE FLOOD HAZARD BOUNDARIES SHALL BE
DELINEATED, WHEN APPLICABLE.
16. NEARBY WETLANDS AND OTHER ENVIRONMENTALLY SIGNIFICANT RESOURCES SHOULD BE CLEARLY
LABELED. CONTRACTOR MAY RELY UPON DEMARCATION SHOWN IN THE PLANS.
17. STORM WATER MANAGEMENT SYSTEM FEATURES INCLUDING DIMENSIONS OF: WET AND DRY SWALES, WET AND DRY PONDS, CONVEYANCE SYSTEMS, EASEMENTS, ALONG WITH ALL ASSOCIATED M.E.S.
STRUCTURES AND INVERTS, OUTFALL STRUCTURES AND INVERTS, SKIMMERS, DISCHARGE STRUCTURES AND INVERTS AND SLOT ELEVATIONS, TOP OF BANK, SLOPE OF BANK AND BOTTOM OF ALL PONDS, SWALES, CLOSED AND OPEN CONVEYANCES. FOR FEMA LOMR SUBMITTALS ALSO PROVIDE: FINISHED
FLOOR ELEVATIONS, SPOT ELEVATIONS AND/OR CONTOURS SHOWING LOWEST LOT ELEVATIONS.
18. THE ENGINEER OF RECORD SHALL REVIEW AND APPROVE THE AS-BUILT PRIOR TO SUBMISSION TO THE CITY FOR FINAL APPROVAL. WRITTEN APPROVAL BY THE ENGINEER OF RECORD SHALL BE NOTED ON A TRANSMITTAL WITH A STATEMENT OF NO EXCEPTIONS TO MINIMUM STANDARDS PROVIDED HEREIN.
MINIMUM REQUIRED STORM AS-BUILTS
FOLLOWING IS A LIST OF INFORMATION THAT IS TO BE VERIFIED AND SUBMITTED BY THE
CONTRACTOR IN SUPPORT OF THE STORMWATER "AS-BUILT" CERTIFICATION.
AS-BUILT DRAWINGS ARE TO BE BASED ON THE CONSTRUCTION DRAWINGS PERMITTED BY THE FDEP, NWFWMD, OR SANTA ROSA COUNTY AND REVISED AS NECESSARY TO REFLECT ANY CHANGES MADE DURING CONSTRUCTION. BOTH THE ORIGINAL DESIGN AND CONSTRUCTED CONDITION MUST BE CLEARLY SHOWN. THE PLANS NEED TO BE CLEARLY LABELED AS "AS-BUILT" OR "RECORD" DRAWINGS. ALL SURVEYED DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED AND SIGNED, DATED, AND SEALED BY A REGISTERED PROFESSIONAL. THE FOLLOWING INFORMATION, AT A MINIMUM, SHALL BE VERIFIED ON
THE STORMWATER AS-BUILT DRAWINGS, AND SUPPLEMENTAL DOCUMENTS, IF NEEDED:
8. DISCHARGE/INLET STRUCTURE(S) - DIMENSIONS AND ELEVATIONS OF ALL, INCLUDING PIPE INVERTS, GRATE ELEVATIONS, RISER ELEVATIONS, GRAVEL BOTTOM, TOP ELEVATIONS, ORIFICES, GATES, PUMPS AND PIPES.
9. SYSTEM GRADING - DIMENSIONS, ELEVATIONS, CONTOURS, FINAL GRADES OR CROSS-SECTIONS TO
DETERMINE HIGH POINTS / LOW POINTS AND CONTRIBUTING AREAS, FLOW DIRECTIONS, AND
CONVEYANCE OF RUNOFF TO THE SYSTEM DISCHARGE POINT(S).
10. CONVEYANCE - MATERIALS, DIMENSIONS, ELEVATIONS, INVERTS, CONTOURS, FINAL GRADES OR CROSS-SECTIONS OF SYSTEMS UTILIZED TO TRANSPORT ONSITE RUNOFF AND/OR DIVERT OFF-SITE
RUNOFF AROUND OR THROUGH THE NEW SYSTEM.
11. WATER LEVEL(S) - EXISTING WATER ELEVATION(S) AND THE DATE DETERMINE, WHEN APPLICABLE.
12. BENCHMARK(S) - LOCATION AND DESCRIPTION (MINIMUM OF ONE PER MAJOR WATER CONTROL
STRUCTURE).
MINIMUM TECHNICAL STANDARDS CHECKLIST FOR UTILITY AS-BUILTS (SURVEYORS AND MAPPERS MUST MEET THE FOLLOWING MINIMUM STANDARDS OF ACCURACY, COMPLETENESS, AND QUALITY FOR
THE UTILITY AS-BUILTS.)
13. MUST IDENTIFY THE RESPONSIBLE SURVEYOR AND MAPPER.
14. SHALL STATE THE TYPE OF SURVEY IT DEPICTS AND THE PURPOSE OF THE SURVEY.
15. MUST BEAR THE NAME, CERTIFICATE OF AUTHORIZATION NUMBER, AND STREET AND MAILING ADDRESS OF THE BUSINESS ENTITY ISSUING THE AS-BUILT SURVEY, ALONG WITH THE NAME AND
LICENSE NUMBER OF THE SURVEYOR IN RESPONSIBLE CHARGE.
16. MUST REFLECT A SURVEY DATE, WHICH IS THE DATE OF ACQUISITION. WHEN THE GRAPHICS OF THE AS-BUILT SURVEY ARE REVISED, BUT THE SURVEY DATE STAYS THE SAME, THE AS-BUILT
SURVEY MUST LIST DATES FOR ALL REVISIONS.
17. MUST BE SIGNED AND SEALED BY THE SURVEYOR IN RESPONSIBLE CHARGE.
18. A DESIGNATED "NORTH ARROW" AND EITHER A STATED SCALE OR GRAPHIC SCALE SHALL BE
SHOWN.
19. APPROPRIATE LINE TYPES, LINE WEIGHTS, AND LINE WIDTHS SHALL BE USED ON THE AS-BUILT DRAWING TO DIFFERENTIATE EXISTING FROM PROPOSED AND WATER FROM SEWER, RECLAIM, AND STORM. ALL PHYSICAL ITEMS (I.E. PIPES, VALVES, ETC.), SURVEYED BOUNDARIES, AND EASEMENTS
SHOULD BE CLEARLY MARKED, AND DIMENSIONED, AND IDENTIFIED BY SIZE AND MATERIAL.
ROADWAY NOTES:
20. CONTRACTOR SHALL PREPARE THE SUB-GRADE TO LINE AND GRADES REQUIRED FOR FINISHED
ELEVATIONS AS INDICATED ON THESE PLANS. ORGANIC MATERIALS, HARD PANS, AND OTHER
UN-SUITABLE SOILS IN THE SUB GRADE SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF
RECORD. COMPACT THE SUB-GRADE TO A MINIMUM OF 96% WITH AN AVERAGE OF 98% OF THE
MODIFIED PROCTOR AS DETERMINED BY A.S.T.MN D 1557. THE COMPACTED SUN-GRADE SHALL HAVE A
MINIMUM LBR OF 40.
21. SEED, FERTILIZE, AND MULCH OR SOD SHOULDERS AND UN-PAVED AREAS WITHIN THE
RIGHT-OF-WAY. ALL WORK SHALL CONFORM TO THE F.D.O.T. SPECIFICATIONS SECTION 570 AND TO THE
SPECIFICATIONS. WHICHEVER IS MORE STRINGENT.
22. COMPACT THE BASE TO A MIN. OF 98% OF THE MODIFIED PROCTOR AS DETERMINED BY A.S.T.M. D 1557. MATERIAL SHALL MEET THE REQUIREMENTS OF THE F.D.O.T. STANDARD SPECIFICATIONS FOR
THE SELECTED BASE MATERIAL. INSTALLATION SHALL BE IN ACCORDANCE WITH F.D.O.T.
SPECIFICATIONS, SECTION 240.
23. PRIME BASE WITH CUTBACK ASPHALT GRADE RC-70 IN ACCORDANCE WITH F.D.O.T.
SPECIFICATIONS, SECTION 300. PROVIDE DENSITY TESTS FOR THE BASE AT 200-FOOT INTERVALS ALTERNATING FROM CENTERLINE TO CENTERLINE OF RIGHT AND LEFT DRIVING LANES. CERTIFIED
TESTING LABORATORY RESULTS ARE REQUIRED FOR DENSITY TEST OF BASE.
24. ALL ROADWAY AND TRAFFIC MARKINGS/STRIPING SHALL COMPLY WITH THE APPLICABLE SECTIONS
OF THE F.D.O.T. STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION.
25. TEMPORARY TRAFFIC CONTROL THROUGH THE WORK ZONE SHALL BE IN ACCORDANCE WITH THE
F.D.O.T. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
GENERAL NOTES
1. THE CONTRACTORS SHALL NOTIFY THE COUNTY PROJECT MANAGER 48 HOURS PRIOR TO CONSTRUCTION.
2. ALL CONDITIONS AND STIPULATIONS OF THE CONSTRUCTION PERMITS AND THE APPROVALS ISSUED BY THE FDOT AND
THE SANTA ROSA COUNTY ENGINEER SHALL BE COMPLIED WITH IN EVERY DETAIL.
3. ALL ROADS DAMAGED BY CONSTRUCTION OPERATIONS ARE TO BE PATCHED OR RECONSTRUCTED AS DIRECTED BY THE
COUNTY ENGINEER OR DESIGNEE.
4. THE CONTRACTOR SHALL TAKE STEPS NECESSARY TO PREVENT EROSION AND ANY OFF SITE SEDIMENT TRANSPORT RESULTING FROM INCREASED RUNOFF DURING CONSTRUCTION BY PROVIDING SILT FENCE AS REQUIRED BY THE STATE OF FLORIDA EROSION AND SEDIMENT CONTROL DESIGNER AND REVIEWER MANUAL, 2013 EDITION, OR AS INDICATED ON THE PLANS. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ASSOCIATED DISTURBED AREAS ARE STABILIZED AS TO REDUCE SEDIMENT RUNOFF, UNLESS OTHERWISE DIRECTED BY THE ENGINEER OR DESIGNEE.
5. ANY NECESSARY PERMITS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. SANTA ROSA COUNTY OR ITS DESIGNEE
WILL ASSIST CONTRACTOR WITH REQUIRED PERMITS.
6. THE CONTRACTOR IS CAUTIONED TO VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE PROJECT PRIOR TO BIDDING
AND/OR CONSTRUCTION.
7. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PRESERVE OR RELOCATE ALL BENCHMARKS (VERTICAL CONTROL) AS NEEDED DURING CONSTRUCTION. ALL PUBLIC OR PRIVATE CORNER MONUMENTATION SHALL BE PROTECTED. IF A PUBLIC OR PRIVATE CORNER MONUMENTATION IS IN DANGER OF BEING DESTROYED AND HAS NOT BEEN PROPERLY REFERENCED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OR DESIGNEE IMMEDIATELY. ANY SANTA ROSA COUNTY HARN/GPS NETWORK MONUMENTS OR BUREAU OF SURVEY AND MAPPING GPS NETWORK MONUMENTS WITHIN THE LIMITS OF CONSTRUCTION SHALL BE PROTECTED. IF A HARN/GPS NETWORK MONUMENTS OR BUREAU OF SURVEY AND MAPPING GPS NETWORK MONUMENTS ARE DISTURBED OR DESTROYED THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OF THE MONUMENTS AND HAVE THE MONUMENTS POSITION DETERMINED BY A FLORIDA LICENSED PROFESSIONAL SURVEYOR AND MAPPER USING GUIDELINES
AS ESTABLISHED BY NATIONAL GEODETIC SURVEY FOR BLUE BOOKING AND APPROVAL.
8. EXISTING DRAINAGE FEATURES WITHIN CONSTRUCTION LIMITS SHALL REMAIN UNLESS OTHERWISE NOTED.
9. THE CONTRACTOR SHALL MATCH EXISTING CONDITIONS AT THE BEGINNING AND END OF CONSTRUCTION AS DIRECTED BY
THE COUNTY ENGINEER OR DESIGNEE.
11. EXISTING STREET AND ROAD NAME SIGNS ON THE PROJECT SHALL BE KEPT VISIBLE AT ALL TIMES FOR THE FACILITATION OF ACCESS BY EMERGENCY VEHICLES. ALL OTHER EXISTING SIGNS THAT CONFLICT WITH CONSTRUCTION OPERATIONS SHALL BE TAKEN DOWN AND STOCKPILED WITHIN THE R/W LIMITS BY THE CONTRACTOR AS DIRECTED BY THE COUNTY ENGINEER OR DESIGNEE. ANY EXISTING SIGNS THAT ARE TO BE RELOCATED AND ARE DAMAGED BEYOND USE BY THE
CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR AT HIS EXPENSE.
12. ONLY ACCESS TO THE ROAD R/W AS SHOWN IS GUARANTEED BY THE COUNTY. PRIVATE R/W REQUIRED BY THE CONTRACTOR TO FACILITATE CONSTRUCTION SHALL BE ACQUIRED BY THE CONTRACTOR WITH NO ADDITIONAL COMPENSATION
OR ASSISTANCE FROM THE COUNTY.
13. IN THE EVENT THAT SURVEY MONUMENTATION OR REFERENCE POINTS ARE MISSING OR HAVE BEEN DESTROYED, PLEASE
CONTACT THE SANTA ROSA COUNTY SURVEYING DEPARTMENT.
14. VEGETATION ON R/W AND EASEMENTS SHALL BE RESTORED TO ORIGINAL CONDITION UNLESS OTHERWISE NOTED ON THE PLAN SHEETS. COST OF SAID RESTORATION SHALL BE CONSIDERED INCIDENTAL TO OTHER PAY ITEMS.
15. ALL COMPACTED FILL SHALL BE PLACED IN 4" LIFTS FOR HAND POWERED TAMPERS AND 8" LIFTS FOR HEAVY EQUIPMENT
OPERATED TAMPERS.
16. ALL CONSTRUCTION IS TO COMPLY WITH FDOT 2023-24THSTANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION.
17. ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC. ALL SIGNING AND PAVEMENT MARKINGS SHALL BE PLACED IN ACCORDANCE WITH THE LATEST FDOT DESIGN STANDARDS. THE CONTRACTOR SHALL CONTACT THE COUNTY PROJECT MANAGER
PRIOR TO INSTALLATION OF ANY SIGNING AND PAVEMENT MARKINGS.
18. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED IN THE AREAS PROPOSED FOR PAVING, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE COUNTY ENGINEER OR DESIGNEE PRIOR TO ANY EXCAVATION.
19. PIPE LENGTHS SHOWN IN THE PLANS DO NOT INCLUDE THE LENGTH OF PIPE THAT MUST BE INSTALLED WITH THE MITERED END SECTION. THEREFORE, ALL PIPE LENGTHS ASSOCIATED WITH MITERED END SECTIONS SHALL BE PAID FOR IN
THE UNIT COST OF THE MITERED END SECTION.
20. ALL CONTRACTORS, COUNTY REPRESENTATIVES, AND UTILITY COMPANIES ARE RESPONSIBLE FOR THEIR RESPECTIVE SURVEYING AND LAYOUT. ANY SURVEYING MONUMENTATION DISTURBED DURING CONSTRUCTION SHALL BE REPLACED UPON
COMPLETION OF THE WORK BY A REGISTERED LAND SURVEYOR IN THE STATE OF FLORIDA.
21. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXISTING SITE CONDITIONS, INCLUDING SOIL CONDITIONS PRIOR TO BIDDING ON THE PROJECT. A COPY OF THE GEOTECHNICAL REPORT, IF APPLICABLE, IS INCLUDED IN THE CONTRACT
DOCUMENTS FOR THE CONTRACTORS REFERENCE.
22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE REQUIRED TESTING TO ENSURE THAT PROPER COMPACTION HAS BEEN ACHIEVED ON THE SUBGRADE, BASE AND ALL OTHER PERTINENT AREAS THAT HAVE BEEN COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS OF TESTING AND RETESTING AS REQUIRED AND SHALL PROVIDE THE
COUNTY WITH COPIES OF CERTIFIED TESTING REPORTS.
23. THE LOCATION OF ALL EXISTING UTILITIES AND STORM DRAINAGE SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE ACCURACY. IT IS THE CONTRACTORS RESPONSIBILITY PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITIES TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE ANY REQUIRED ARRANGEMENTS FOR ANY RELOCATIONS OF THESE UTILITIES WITH THE OWNER OF SAID UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES, WHETHER SHOWN ON THE PLAN OR LOCATION BY THE UTILITY. ANY UTILITIES THAT INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL TO BROUGHT TO THE ATTENTION OF THE ENGINEER. ANY FEES ASSOCIATED WITH UTILITY RELOCATIONS SHALL BE BORNE IN ACCORDANCE WITH RESPECTIVE UTILITY COMPANY STANDARDS.
ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE RELOCATION OF ANY UTILITIES SHALL BE INCIDENTAL
TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED.
24. THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE COUNTY, ENGINEER OF RECORD, UTILITY
COMPANIES AND CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
25. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT NO CONSTRUCTION ACTIVITIES TAKE PLACE OUTSIDE OF THE EXISTING R/W OR EASEMENTS SHOWN ON THE PLANS. ANY ON-SITE OR OFFSITE AREAS THAT ARE DISTURBED SHALL
BE RESTORED TO ORIGINAL CONDITION OR BETTER AS DIRECTED BY THE ENGINEER.
26. THE CONTRACTOR SHALL BE RESPONSIBLE TO SAFETY BARRICADE ALL EXCAVATIONS AND OTHER HAZARDS.
27. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY CONFLICTS BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS. THE DRAWINGS REPRESENT KNOWN STRUCTURES AND UTILITIES LOCATED WITHIN THE PROJECT AREA, THE CONTRACTOR IS CAUTIONED THAT OTHER STRUCTURES AND UTILITIES, ABOVE OR BELOW GROUND, MAY BE
ENCOUNTERED DURING THE COURSE OF CONSTRUCTION.
28. ALL MATERIALS AND CONSTRUCTION TO BE IN ACCORDANCE WITH THE PROJECT MANUAL. ALL MATERIALS STORAGE AREAS
SHALL BE CLEARLY IDENTIFIED AND SECURED BY THE CONTRACTOR.
29. ALL NEW CONCRETE FOR THE PROJECT WILL BE FDOT 3000 PSI N.S. CLASS (NON STRUCTURAL), UNLESS OTHERWISE
NOTED.
30. ALL TREES IN THE PROJECT AREA ARE TO REMAIN UNDAMAGED UNLESS OTHERWISE NOTED FOR REMOVAL.
31. THE CONTRACTOR IS TO REPLACE TO EXISTING CONDITION OR BETTER ANY FENCES, SPRINKLER SYSTEMS, TREES, SHRUBS, FLOWER BEDS, OR OTHER EXISTING IMPROVEMENTS IMPACTED DURING CONSTRUCTION, WHETHER DEPICTED ON THE
PLANS OR NOT.
32. ALL DIMENSIONS AND GRADES ON THESE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE RE-DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH
NOTIFICATION HAS NOT BEEN GIVEN.
33. ALL DISTURBED AREAS WHICH ARE NOT PAVED SHALL BE STABILIZED WITH SEEDING FERTILIZER AND SOD. THE CONTRACTOR SHALL FURNISH TO THE ENGINEER (PRIOR TO INCORPORATION INTO THE PROJECT) A CERTIFICATION FROM THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES DIVISION OF PLANT INDUSTRY STATING THAT THE SOD/ HAY/ STAW/ MULCH/ SEED MATERIALS ARE FREE OF NOXIOUS WEEDS INCLUDING TROPICAL SODA APPLE. SOD IS
RECOMMENDED SLOPE STABILIZATION METHOD.
34. AT MINIMUM, A TRENCH BOX IS EXPECTED TO BE NEEDED FOR ALL PIPE INSTALLATIONS. CONTRACTOR TO BID
ACCORDINGLY. SOME TRENCHES ARE VERY CLOSE TO R/W LINES & EXISTING IMPROVEMENTS.
35. BACKFILL FOR TRENCHES TO CONSIST OF NON-PLASTIC, SLIGHTLY SILTY SAND WITH FINES CONTENT BETWEEN 10%-20% USCS (SP-SM, SP-SC, SM) BACKFILL TO HAVE MODIFIED PROCTOR DRY DENSITY OF AT LEAST 100 PCF.
36. ALL EXISTING MAILBOXES INTERFERING WITH NEW CONSTRUCTION SHALL BE RELOCATED BY THE CONTRACTOR IN ACCORDANCE WITH POSTAL REQUIREMENTS AND IN ACCORDANCE WITH SANTA ROSA COUNTY STANDARDS, FDOT DESIGN STANDARDS AND UNITED POSTAL REQUIREMENTS. ALL EXISTING BRICK MAILBOXES WITHIN LIMITS OF CONSTRUCTION OR COUNTY RIGHT OF WAY SHALL BE REMOVED AND PLACED ON THE PROPERTY LINE OF THE OWNER. CONTRACTOR SHALL
REPLACE EXISTING BRICK MAILBOX WITH APPROVED PLASTIC BREAK AWAY MAILBOX.
SURVEY NOTES
1. TOPOGRAPHIC SURVEY PERFORMED BY VOLKERT INC. (MAY 2023), AND ONLY REPRESENTS CONDITIONS AT THE TIME OF THE
SURVEY.
2. HORIZONTAL COORDINATED ARE REFERENCED TO NAD83. VERTICAL ELEVATIONS ARE REFERENCED TO NAVD 88.
3. BLACK BEARS ARE PRESENT IN THE PROJECT AREA AND IT IS IMPORTANT THAT THE CONTRACTOR LET THEIR EMPLOYEES KNOW THAT BLACK BEAR PRESENCE IN THE AREA IS LIKELY. DURING CONSTRUCTION THE CONTRACTOR SHOULD FREQUENTLY REMOVE TRASH FROM THE SITE, ESPECIALLY WILDLIFE ATTRACTANT FOOD DISPOSED OF BY WORKERS. WILDLIFE-RESISTANT TRASH
CONTAINERS ARE ALSO RECOMMENDED.
4. WETLAND AREAS, SURFACE WATER AREAS, AND ASSOCIATED BUFFERS SHALL BE CLEARLY DELINEATED AND PROTECTED PRIOR
TO BEGINNING UPLAND CLEARING.
TESTING FREQUENCIES
1. SUBGRADE - TEST AT 300 FEET INTERVALS, ALTERNATING FROM LEFT SIDE TO CENTERLINE TO RIGHT SIDE WITH ADDITIONAL TESTS AT ALL INTERSECTIONS, CULS-DE-SAC, AND OTHER LOCATIONS AS DIRECTED BY THE COUNTY ENGINEERING DEPARTMENT.
2. BASE - TEST AT 200 FEET INTERVALS, ALTERNATING FROM LEFT SIDE TO CENTERLINE TO RIGHT SIDE WITH ADDITIONAL TESTS AT ALL INTERSECTIONS, CULS-DE-SAC, AND OTHER LOCATIONS AS DIRECTED BY THE COUNTY ENGINEERING DEPARTMENT.
3. ASPHALT - TEST AT 300 FEET INTERVALS, ALTERNATING FROM LEFT SIDE TO CENTERLINE TO RIGHT SIDE WITH ADDITIONAL TESTS AT ALL INTERSECTIONS, CULS-DE-SAC, AND OTHER LOCATIONS AS DIRECTED BY THE COUNTY ENGINEERING DEPARTMENT.
4. ADDITIONAL NOTES
4.1 CITY OF GULF BREEZE PUBLIC WORKS HAS THE AUTHORITY TO
REQUIRE ADDITIONAL TESTING DUE TO WEATHER CONDITIONS.
4.2 IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY SANTA ROSA COUNTY
PUBLIC WORKS OF THE TIME AND DATE THAT THE TESTING
WILL OCCUR AND PROVIDE SANTA ROSA COUNTY PUBLIC WORKS WITH A COPY OF ALL OF
THE TEST RESULTS.
4.3 AREAS WITH ASPHALT DEPTHS LESS THAN THE DESIGN THICKNESS
SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE.
GENERAL NOTES CONT.:
36. DAMAGE TO ANY EXISTING ROADS DURING CONSTRUCTION SHALL BE REPAIRED BY THE CONTRACTOR PRIOR TO FINAL "AS-BUILT"
SIGN-OFF FROM THE COUNTY AT NO ADDITIONAL COST TO THE COUNTY.
37. SHOP DRAWINGS OF ALL MATERIALS BEING USED SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO ORDER, SHIPMENT, OR INSTALLATION.
38. THE CONTRACTOR SHALL MAINTAIN RECORD DRAWINGS DURING CONSTRUCTION WHICH SHOW "AS-BUILT" CONDITIONS OR ALL WORK.
RECORD DRAWINGS SHALL BE PROVIDED TO THE ENGINEER PRIOR TO REQUESTING A FINAL INSPECTION.
39. THE CONTRACTOR SHALL SCHEDULE WITH THE COUNTY INTERMEDIATE AND A FINAL INSPECTION UPON COMPLETION OF ALL WORK.
AS-BUILT CERTIFICATION IS REQUIRED PRIOR TO REQUEST FOR FINAL INSPECTION.
40. ALL ASPECTS OF STORMWATER/DRAINAGE AND/OR TRANSPORTATION COMPONENTS SHALL BE COMPLETED PRIOR TO REQUESTING A FINAL
INSPECTION.
41. NO DEVIATIONS OR REVISION FROM THE PLANS BY THE CONTRACTOR SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM BOTH THE ENGINEER OF RECORD AND SANTA ROSA COUNTY. ANY DEVIATION MAY RESULT IN DELAYS IN THE COUNTY'S ACCEPTANCE OF IMPROVEMENTS.
42. IF ARCHAELOGICAL MATERIAL/PREHISTORIC ARTIFACTS SUCH AS POTTERY OR CERAMICS, STONE TOOLS OR METAL IMPLEMENTS, OR ANY OTHER PHYSICAL REMAINS THAT COULD BE ASSOCIATED WITH NATIVE AMERICAN CULTURES, OR EARLY COLONIAL OR AMERICAN SETTLEMENT ARE ENCOUNTERED AT ANY TIME, THE PROJECT SHOULD CEASE ALL ACTIVITIES INVOLVING SUBSURFACE DISTURBANCE IN THE IMMEDIATE VICINITY OF SUCH DISCOVERIES. THE APPLICANT/RECIPIENT, OR OTHER DESIGNEE, SHOULD CONTACT THE FLORIDA DEPARTMENT OF STATE, DIVISION OF HISTORICAL RESOURCES, THE STATE HISTORIC PRESERVATION OFFICER (SHPO) AND THE DSH/FEMA REGION IV ENVIRONMENTAL OFFICER AND FDEM STATE ENVIRONMENTAL LIAISON OFFICER FOR FURTHER GUIDANCE. PROJECT ACTIVITIES SHOULD NOT RESUME WITHOUT VERBAL AND/OR WRITTEN AUTHORIZATION FROM THE THE DIVISION OF HISTORICAL RESOURCES.
43. IN THE EVENT THAT UNMARKED HUMAN REMAINS ARE ENCOUNTERED DURING PERMITTING ACTIVITIES, ALL WORK MUST STOP IMMEDIATELY AND THE PROPER AUTHORITIES NOTIFIED IN ACCORDANCE WITH SECTION 872.05, FLORIDA STATUTE.
44. THE CONTRACTOR IS RESPONSIBLE FOR ANY INCIDENTAL WORK ASSOCIATED WITH THE SIDEWALK CONSTRUCTION SUCH AS IRRIGATION
REPAIRS/RELOCATES, ETC.
UTILITY NOTES:
1. THE LOCATION SHOWN FOR EXISTING UNDERGROUND UTILITIES IS APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK IN EACH AREA. THE CONTRACTOR AGREES TO BE COMPLETELY RESPONSIBLE FOR ALL DAMAGES WHICH
MIGHT OCCUR BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ALL UTILITIES.
2. UTILITY OWNERS SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY CONSTRUCTION SO THAT THE UTILITY OWNER CAN SPOT VERIFY AND/OR
EXPOSE THEIR UTILITIES.
KNOWN UTILITIES OWNERS INCLUDE:
ELECTRIC - FLORIDA POWER AND LIGHT-GULF BREEZE
GULF POWER, ONE ENERGY PL, PENSACOLA, FL 32520
(850) 777-9476, DEREK.GILMORE@FPL.COM
WATER/SEWER - FAIRPOINT REGIONAL UTILITIES,
8574 TURKEY BLUFF RD, NAVARRE, FL 32566
(850) 939-2427, CWELLS@HNWS-FL.COM
WATER/SEWER - MIDWAY WATER SYSTEM, INC.
4971 GULF BREEZE PKWY, GULF BREEZE, FL 32563
(850) 932-5188, JANDERSON@MIDWAYWATER.COM
NATURAL GAS - CITY OF GULF BREEZE,
1070 SHORELINE DR, GULF BREEZE, FL 32561
(850) 490-3030, RBLACK@GULFBREEZEFL.GOV
CATV - MEDIACOM SOUTHEAST LLC
1613 NANTAHALA BEACH RD, GULF BREEZE, FL 32563
(845) 608-1038, JGIPE@MEDIACOMCC.COM
TELEPHONE - AT&T/DISTRIBUTION,
605 WEST GARDEN ST, PENSACOLA, FL 32501
(850)436-1485, KF5345@ATT.COM
CITY OF GULF BREEZE SEWER
1070 SHORELINE DR, GULF BREEZE, FL 32561
(850) 934-4056, JNORRIS@GULFBREEZEFL.GOV
3. ALL CABLE DAMAGE MUST BE REPORTED TO THE ATT FLORIDA REPAIR SERVICE DEPARTMENT AT 611 FROM A LAND LINE OR 877-737-2478 IF USING A CELL
PHONE.
4. CONTRACTOR IS TO USE CAUTION WHEN WORKING IN OR AROUND AREAS OF OVERHEAD TRANSMISSION LINES AND UNDERGROUND UTILITIES.
5. UTILITIES TO REMAIN AND BE PROTECTED DURING CONSTRUCTION. NECESSARY REPAIRS SHALL BE CONSIDERED INCIDENTAL TO OTHER PAY ITEMS AND
SHALL BE TO THE SATISFACTION OF UTILITY OWNERS.
6. ADEQUATE PROVISIONS SHALL BE MADE FOR THE FLOW OF SEWERS, DRAINS, WATER COURSES AND OTHER UTILITIES ENCOUNTERED DURING
CONSTRUCTION.
7. THE CONTRACTOR SHALL PROTECT ALL UTILITIES AND OTHER IMPROVEMENTS SHOWN AND NOT SHOWN ON THE PLANS. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR REPAIRS OF UTILITIES AND OTHER IMPROVEMENTS(SHOWN AND UN-SHOWN) DAMAGED DURING CONSTRUCTION AND SHALL MAINTAIN SUFFICIENT PROTECTION FOR ALL UTILITIES TO REMAIN. THE CONTRACTOR SHALL SUPPORT ALL EXISTING UTILITIES AS REQUIRED FOR THE INSTALLATION OF THE PROPOSED IMPROVEMENTS. ALL COSTS ASSOCIATED WITH PROTECTING, SUPPORTING, REPAIRING, AND OTHER ACTIVITIES RESULTING FROM CONTRACTOR DAMAGE TO THE UTILITIES OR PROTECTION OF THE UTILITIES SHALL BE THE CONTRACTORS RESPONSIBILITY AT NO ADDITIONAL COST TO THE COUNTY.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTMENT OF EXISTING UTILITIES IF PROPOSED IMPROVEMENTS IMPACT EXISTING UTILITIES.
9. APPROXIMATE LOCATIONS AND OBSERVED POTENTIAL AND/OR KNOWN CONFLICTS ARE INDICATED ON THESE DRAWINGS.
PROJECT WORK HOURS:
1. PROJECT WORK HOURS ARE RESTRICTED TO 7 AM TO 5 PM, SEVEN DAYS A WEEK.
2. LANE CLOSURES ARE PROHIBITED BETWEEN THE HOURS OF 6:00 AM AND 8:30 AM AND
2:00 PM AND 4:30 PM MONDAY - FRIDAY WHILE SCHOOL IS IN SESSION.
TEMPORARY TRAFFIC CONTROL PLAN GENERAL NOTES
1. LANE CLOSURE/WORK RESTRICTIONS: NO CONSTRUCTION SHALL BE ALLOWED ON WEEKENDS OR DURING SPECIAL EVENTS. NO LANE OR SIDEWALK CLOSURES
ARE PERMITTED DURING CONSTRUCTION.
2. ALL LANES MUST BE OPEN TO NORMAL TRAFFIC WITHIN 12 HOURS OF AN EVACUATION NOTICE FOR A HURRICANE OR ANY OTHER EMERGENCY EVENT AND
SHALL REMAIN OPEN UNTIL OTHERWISE DIRECTED BY THE ENGINEER.
3. THE CONTRACTOR MAY SUBMIT AN ALTERNATIVE TEMPORARY TRAFFIC CONTROL PLAN FOR REVIEW AND APPROVAL BY ENGINEER OF RECORD AND SANTA ROSA
COUNTY PROJECT MANAGER.
TEMPORARY TRAFFIC CONTROL PLAN PHASING NOTES
1. ALL PHASES:
· MAINTAIN TRAFFIC DURING ALL PHASES UTILIZING STANDARD PLAN INDICES 102-600, 102-601, 102-602, AND 102-603
· INSTALL ALL ADVANCE WARNING SIGNS PER STANDARD INDICES 102-600, 102-601, 102-602, AND 102-603
· CONSTRUCT IMPROVEMENTS IN WORKZONE
· REMOVE ALL ADVANCE WARNINGS SIGNS AT COMPLETION OF CONSTRUCTION 2 23
AutoCAD SHX Text Engineers Surveyors Planners
215 FAIRPOINT DR SUITE B GULF BREEZE, FL 32561 Telephone (850) 512-8935
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
SU
M
M A
R Y
O F
Q U
A N
TI
TI
ES
3 23
AutoCAD SHX Text Engineers Surveyors Planners
11.5' TRAVEL LANE
47.5' RIGHT OF WAY
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
11.5' TRAVEL LANE
2% MINIMUM 2% MINIMUM
47.5' RIGHT OF WAY
95' RIGHT OF WAY
TYPICAL SECTION
6" GRADED AGGREGATE BASE 98%
MODIFIED PROCTOR LBR 100 12" TYPE "B" STABILIZED SUBGRADE
98% MODIFIED PROCTOR LBR 40
6%
PROPOSED
HEADWALL
STA. 125+70.85 TO 126+70.85
8'-0" 6'-6"
℄ CONSTRUCTION
6'-6" 8'-0"
PROPOSED
HEADWALL
EXIST. 8'
SIDEWALK
NEW CONSTRUCTION
2" SP 9.5 ASPHALT
6" GRADED AGGREGATE BASE
12" STABILIZED SUBGRADE (MINIMUM LBR OF 40) STA. 203+29.76 TO 204+34.84
N.T.S.
STA. 229+30.94 TO 230+30.94
STA. 243+37.65 TO 244+37.65
TY
PI
C A
L
SE
C
TI
O N
S
4 23
1:6
SOD
SHOULDER
6%1:6
SOD
SHOULDER
EXISTING GRADE
EXISTING
GRADE
TYPICAL SECTION - FULL REBUILD
6" GRADED AGGREGATE BASE
12" STABILIZED SUBGRADE
(MINIMUM LBR OF 40)
2" TYPE SP 9.5 ASPHALTIC
CONCRETE
2" TYPE SP 9.5 ASPHALTIC
CONCRETE
2% MINIMUM
14.5'
AutoCAD SHX Text Engineers Surveyors Planners
CD-9 CULVERT REPLACEMENT
SEE SHEET 12
CD-7 CULVERT REPLACEMENT
SEE SHEET 10
CD-4 CULVERT REPLACEMENT
SEE SHEET 8
CD-1 CULVERT REPLACEMENT
SEE SHEET 6
EAST BAY
EA
ST
B
AY
B
LV
D.
B E
RGRE
N RD
US 98
E D
GE
W
OOD
D R
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
Feet 0 2000 4000
PR
O
JE
C
T
LO
C A
TI
O
N M
A P
5 23
AutoCAD SHX Text Engineers Surveyors Planners
EXIST. 15" CPP
APPROXIMATE R/W
APPROXIMATE R/W
EXIST. 6" WATER MAIN
EXIST. GAS LINE
TO REMAIN
EXIST. UNKNOWN
UTILITY TO REMAIN
EXIST. WATERLINE
TO REMAIN
CD 1
EXIST CONCRETE HEADWALL TO
BE REMOVED STATION 126+20.15
OFFSET 18.17' RT, INV. 9.74
CONCRETE MES
TO REMAIN
TOP OF BANK
PERMANENT SIDEWALK
TO BE PROTECTED
ASPHALT TO BE REMOVED
STA. 126+17.01 TO STA. 126+33.52
SAW CUT EXIST. ASPHALT
PROP. SILT FENCE
E
AS
T B
AY
B
LV
D
8'
11.5'11.5'
5.3'6.5'
EXIST. 38 LF 24" RCP
@0.29% TO BE REMOVED
INV. 9.64
EXIST CONCRETE HEADWALL TO
BE REMOVED. STATION 126+22.83
OFFSET 19.14' LT, INV. 9.85
HEADWALL TO REMAIN
SAWCUT EXIST. ASPHALT
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
N Feet
0 20 40
6 23
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
- D
EM
O
LI
TI
O N
P
LA
N C
D -1
CD X
Legend
-SF- Silt Fence
Cross Drain
Major Contour
Minor Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Wetlands
Floating Turbidity Curtain
CONTRACTOR NOTES
1.CONTRACTOR TO PROTECT ALL ITEMS UNLESS OTHERWISE NOTED TO BE REMOVED.
2. CONTRACTOR TO LOCATE ALL UTILITIES (HORIZONTAL AND VERTICAL LOCATIONS)
3. CONTRACTOR TO RELOCATE/REUSE EXISTING RIPRAP AS NEEDED.
4. ALL COSTS FOR CONSTRUCTION SHALL BE INCLUDED IN THE CONTRACTOR'S LUMP
SUM BID.
5.ALL EXCAVATED AND DISTURBED AREAS SHALL BE RESTORED WITH SOD.
6. SOD TYPE SHALL BE THE SAME AS EXISTING LAWN GRASS.
7. ZOYSIA OR APPROVED EQUAL SHALL BE USED WHERE EXISTING GRASS TYPE IS
NOT APPARENT, SOD ALL DISTURBED AREAS.
8. SOD ALL DISTURBED AREAS AND REPLACE DAMAGED LANDSCAPING AS NECESSARY
TO MATCH EXISTING SOD TYPE AND PRE-CONSTRUCTION CONDITION.
9. CONTRACTOR TO VERIFY REQUIRED QUANTITY FOR RIP-RAP APRONS.
QUANTITY OF RIP-RAP ONLY FOR CD-1.
AutoCAD SHX Text Engineers Surveyors Planners
5" C
P P
9.709.64
CD 1
CONST. CONCRETE HEADWALL
STATION 126+22.83 OFFSET 26' LT
INV. EL. = 9.64'
CONST. CONCRETE HEADWALL
STATION 126+20.15 OFFSET 26.5' RT
INV. EL.= 9.70'
EXIST. CONCRETE MES
INV. =9.64 TO REMAIN
EXIST. ASPHALT PATH
TO REMAIN
E
AS
T B
AY
B
LV
D
8'
11.5'11.5'
17'
CONST. 57 LF
24" RCP @0.1%
EXIST. SANDBAG RETAINING WALL
TO REMAIN
APPROXIMATE R/W
CONST. SILT FENCE
CONST. SILT FENCE
APPROXIMATE R/W
A A
9.11 SQ. YD. OF
PROPOSED RIPRAP
SURVEY CONTROL POINT
NORTHING = 520361.115
EASTING = 1180496.245
ELEV. = 12.00'
14.5'
EXIST. 12" WATERLINE TO REMAIN
EXIST. UNKNOWN UTILITY TO REMAIN
EXIST. GAS LINE TO REMAIN
PROPOSED
24" RCP
EXISTING PIPE
(TO BE REMOVED)
PROP. CONC.
HEADWALL
INV.=9.64' INV.=9.70'
PROP. CONC.
HEADWALL
EXIST. 12" WATERLINE
TO REMAIN
EXIST. UNKNOWN
UTILITY TO REMAIN
EXIST. GAS LINE
TO REMAIN
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
N Feet
0 20 40
7 23
PR
O
PO
SE
D C
U
LV
ER
T
PL
A
N C
D
-1CD X
Legend
-SF- Silt Fence
Cross Drain
Existing Major Contour
Existing Minor Contour
Proposed Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Existing Wetlands
Impacted Wetlands
Floating Basin Boom
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
CL
AutoCAD SHX Text R/W
AutoCAD SHX Text R/W
AutoCAD SHX Text
EOS
AutoCAD SHX Text
EOS
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text Engineers Surveyors Planners
N
°0 '5 5" E
WA
TE
R
WA
TE
R
N
°0 '5 5" E
5 4
APPROXIMATE R/W
APPROXIMATE R/W
EXIST. 18" CMP
EXIST. 18" RCP EXIST. 24" CMP
EXIST. 18" PLASTIC PIPE
30' OF EXIST. 24"
CMP TO BE REMOVED
19' OF EXIST. 18" RCP
TO BE REMOVED
EXIST RIP-RAP TO BE REMOVED
AND RELOCATED AS NEEDED
EXIST. 12" WATERMAIN TO REMAIN
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
CD 4
EXIST. CONC. MES
TO REMAIN, INV. 3.89'
EXIST. CONCRETE HEADWALL TO BE REMOVED
STATION 203+75.10, OFFSET 18.17' RT, INV. 2.66'
SAWCUT EXIST. ASPHALT
PROP. SILT FENCE
PROP. SILT FENCE
E
AS
T B
AY
B
LV
D
INV. 2.32'INV. 1.91'
EXIST. MES TO
BE REMOVED
INV. 4.01'
EXIST. CONCRETE MES TO
BE REMOVED, INV. 3.24'
CONCRETE MES TO BE
REMOVED, INV. 3.66'
EXIST. 42 LF 24" RCP PIPE
TO BE REMOVED @0.38%
EXIST 42.5 LF 24" RCP PIPE
TO BE REMOVED @0.96%
EXIST. CONCRETE HEADWALL
TO BE REMOVED
STATION 203+89.43,
OFFSET 22.13' LT, INV. 2.51'
11.5'11.5'
WETLANDS
ASPHALT TO BE REMOVED
STA. 203+64.08 TO STA. 203+92.65
SAWCUT EXIST. ASPHALT
EXIST. WOODEN
BRIDGE TO REMAIN
FLOATING TURBIDITY
CURTAIN
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
N
Feet 0 20 40
8 23
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
- D
EM
O
LI
TI
O N
P
LA
N C
D -4
CD X
Legend
-SF- Silt Fence
Cross Drain
Major Contour
Minor Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Wetlands
Floating Turbidity Curtain
CONTRACTOR NOTES
1.CONTRACTOR TO PROTECT ALL ITEMS UNLESS OTHERWISE NOTED TO BE REMOVED.
2. CONTRACTOR TO LOCATE ALL UTILITIES (HORIZONTAL AND VERTICAL LOCATIONS)
3. CONTRACTOR TO RELOCATE/REUSE EXISTING RIPRAP AS NEEDED.
4. ALL COSTS FOR CONSTRUCTION SHALL BE INCLUDED IN THE CONTRACTOR'S LUMP
SUM BID.
5.ALL EXCAVATED AND DISTURBED AREAS SHALL BE RESTORED WITH SOD.
6. SOD TYPE SHALL BE THE SAME AS EXISTING LAWN GRASS.
7. ZOYSIA OR APPROVED EQUAL SHALL BE USED WHERE EXISTING GRASS TYPE IS
NOT APPARENT, SOD ALL DISTURBED AREAS.
8. SOD ALL DISTURBED AREAS AND REPLACE DAMAGED LANDSCAPING AS NECESSARY
TO MATCH EXISTING SOD TYPE AND PRE-CONSTRUCTION CONDITION.
9. CONTRACTOR TO VERIFY REQUIRED QUANTITY FOR RIP-RAP APRONS.
QUANTITY OF RIP-RAP ONLY FOR CD-1.
AutoCAD SHX Text Engineers Surveyors Planners
WA
TE
R
8" P
LA
S
TI
C
8" C
M P
8" R
C P
N
°0 '5 5" E
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
2.50
2.00
CD 4
EXIST. WOODEN BRIDGE
TO REMAIN
EXIST. CONCRETE MES
INV. 3.89' TO REMAIN
CONST. CONCRETE HEADWALL
STA. 203+75.10 OFFSET 26' RT
INV. EL. = 2.50'
CONST. SILT FENCE
E
AS
T B
AY
B
LV
D
CONST. CONCRETE HEADWALL
STA. 203+89.43 OFFSET 26' LT
INV. EL. = 2.00' 14.5'
14.5'
APPROXIMATE R/W
CONST. SILT FENCE
APPROXIMATE R/W
CONST. JB3
STA. 203+64.70 OFFSET 25.3 LT
TOP EL.= 6.796' INV. EL.= 4.20'
CONST. 11' 18"
RCP @ S=4.1%
CONST. MES
INV. EL.= 3.75'
CONST. JB1
STA. 203+93.69 OFFSET 27.97' RT
TOP EL.= 6.047' INV. EL.= 3.79'
CONST. 18' 18"
RCP @ S=4.4%
CONST. MES
INV. EL.= 3.00'
CONST. JB2
STA. 203+40.59 OFFSET 28.4 LT
TOP EL.= 6.201' INV. EL.= 3.74'
CONST. 22' 24" RCP @ S=3.4%
CONST. MES INV. EL.= 3.00'
11.5'11.5'
B
B
CONST. 56 LF DUAL 24" RCP
@0.9% MATCH EXIST. SKEW ANGLE
REMOVE AND REINSTALL
RIPRAP AS NEEDED
SURVEY CONTROL POINT
NORTHING: 524327.923
EASTING: 1187007.935
ELEV. = 6.84'
263.53 SQ. FT. OF
WETLAND IMPACTS
APPROXIMATE LOCATION
OF EXIST. WATERLINE.
EXIST. 12" WATERLINE TO REMAIN
PROPOSED
24" RCP
EXISTING PIPE
(TO BE REMOVED)
PROP. CONC.
HEADWALL
INV.=2.00' INV.=2.50'
PROP. CONC.
HEADWALL
263.53 SQ. FT. OF
WETLAND IMPACTS
18" FAIRPOINT REGIONAL
UTILITY WATERMAIN
EXIST. 12" WATERLINE
TO REMAIN
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
PR
O
PO
SE
D C
U
LV
ER
T
PL
A
N C
D -4
N
Feet 0 20 40
9 23
CD X
Legend
-SF- Silt Fence
Cross Drain
Existing Major Contour
Existing Minor Contour
Proposed Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Existing Wetlands
Impacted Wetlands
Floating Basin Boom
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
CL
AutoCAD SHX Text R/W
AutoCAD SHX Text R/W
AutoCAD SHX Text
EOS
AutoCAD SHX Text
EOS
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text Engineers Surveyors Planners
POT STA. +62.04
WA
TE
R
WA
TE
R
POT STA. +62.04
3 4
APPROXIMATE R/W
APPROXIMATE R/W
EXIST. 18" CPP
EXIST. 18" CPP
14' OF EXIST. 18" CPP
TO BE REMOVED
EXIST. 12" WATERMAIN TO REMAIN
EXIST. RIP-RAP TO BE REMOVED
AND RELOCATED AS NEEDED
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
CD 7
EXIST. 30" RCP TO BE REMOVED
EXIST. WOODEN
BRIDGE TO REMAIN
EXIST. CONCRETE HEADWALL
TO BE REMOVED
STATION 229+80.48
OFFSET 17.85' RT, INV.4.99'
TOP OF BANK
PROP. SILT FENCE
PROP. SILT FENCE
SAWCUT EXIST. ASPHALT
REMOVE EXIST. ASPHALT
STA. 229+70.94 TO STA. 229+90.94
SAWCUT EXIST. ASPHALT
E
AS
T B
AY
B
LV
D
8'
11.5'11.5'
5.6' 5.1'
INV. 4.33'
INV. 4.46'
EXIST. CONCRETE HEADWALL
TO BE REMOVED
STATION 229+82.92
OFFSET 19.53' LT, INV. 3.99'
WETLANDS
FLOATING TURBIDITY
CURTAIN
11' OF EXIST. 30" RCP
TO BE REMOVED
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
Feet 0 20 40
N
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
- D
EM
O
LI
TI
O N
P
LA
N C
D -7
10 23
CD X
Legend
-SF- Silt Fence
Cross Drain
Major Contour
Minor Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Wetlands
Floating Turbidity Curtain
CONTRACTOR NOTES
1.CONTRACTOR TO PROTECT ALL ITEMS UNLESS OTHERWISE NOTED TO BE REMOVED.
2. CONTRACTOR TO LOCATE ALL UTILITIES (HORIZONTAL AND VERTICAL LOCATIONS)
3. CONTRACTOR TO RELOCATE/REUSE EXISTING RIPRAP AS NEEDED.
4. ALL COSTS FOR CONSTRUCTION SHALL BE INCLUDED IN THE CONTRACTOR'S LUMP
SUM BID.
5.ALL EXCAVATED AND DISTURBED AREAS SHALL BE RESTORED WITH SOD.
6. SOD TYPE SHALL BE THE SAME AS EXISTING LAWN GRASS.
7. ZOYSIA OR APPROVED EQUAL SHALL BE USED WHERE EXISTING GRASS TYPE IS
NOT APPARENT, SOD ALL DISTURBED AREAS.
8. SOD ALL DISTURBED AREAS AND REPLACE DAMAGED LANDSCAPING AS NECESSARY
TO MATCH EXISTING SOD TYPE AND PRE-CONSTRUCTION CONDITION.
9. CONTRACTOR TO VERIFY REQUIRED QUANTITY FOR RIP-RAP APRONS.
QUANTITY OF RIP-RAP ONLY FOR CD-1.
AutoCAD SHX Text Engineers Surveyors Planners
PROPOSED
30" RCP
EXISTING PIPE
(TO BE REMOVED)
PROP. CONC.
HEADWALL
INV.=3.99'
INV.=4.50'
PROP. CONC.
HEADWALL
558.80 SQ. FT. OF
WETLAND IMPACTS
EXIST. 12" WATERLINE
TO REMAIN
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
WA
TE
R
8" C
P P
8" C
P P
34" SPAN X 24" RISE CMP
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
4.503.99
CD 7
EXIST. WOODEN BRIDGE
TO REMAIN
CONST. CONCRETE HEADWALL
STA. 229+80.48 OFFSET 26' RT
INV. EL.= 4.50'
CONST. SILT FENCE
EXIST. ASPHALT PATH
TO REMAIN
APPROXIMATE R/W
E
AS
T B
AY
B
LV
D
8'
11.5'11.5'
14.5'
EXIST. CONCRETE HEADWALL
INV. 3.17' TO REMAIN
CONST. CONCRETE HEADWALL
STA. 229+82.92 OFFSET 25.5' RT
INV. EL.= 3.99'
CONST. SILT FENCE
WETLANDS
CONST. MES
INV. EL.= 4.25'
CONST. 11' 18" RCP
@ S=1.9%
CONST. JB4
STA. 229+94.57 OFFSET 25.3 LT
TOP EL.= 7.417' INV. EL.= 4.44'
CONST. MES
INV. EL.= 4.25'
CONST. 11' 18"
RCP @ S=2.6%
CONST. JB5
STA. 229+68.23 OFFSET 25.2 LT
TOP EL.= 7.213' INV. EL.= 4.52'
APPROXIMATE R/W
C C
REMOVE AND REINSTALL
RIPRAP AS NEEDED
SURVEY CONTROL POINT
NORTHING: 525864.671
EASTING: 1189002.216
ELEV. = 7.88'
558.80 SQ. FT.
WETLAND IMPACTS
CONST. 54.5 LF
30" RCP @0.9%
14'
EXIST. WATERLINE TO REMAIN
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
PR
O
PO
SE
D C
U
LV
ER
T
PL
A
N C
D -7
Feet 0 20 40
N
11 23
CD X
Legend
-SF- Silt Fence
Cross Drain
Existing Major Contour
Existing Minor Contour
Proposed Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Existing Wetlands
Impacted Wetlands
Floating Basin Boom
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
CL
AutoCAD SHX Text R/W
AutoCAD SHX Text R/W
AutoCAD SHX Text
EOS
AutoCAD SHX Text
EOS
AutoCAD SHX Text
SECTION C-C
AutoCAD SHX Text Engineers Surveyors Planners
POT STA. +32.49
WA
TE
R
WA
TE
R
POT STA. +32.49
3 0
-1
APPROXIMATE R/W
APPROXIMATE R/W
EXIST. 12" WATERMAIN TO REMAIN
18" FAIRPOINT REGIONAL UTILITY
WATERMAIN TO REMAIN
EXIST. GAS LINE TO REMAIN
CD 9
EXIST. WOODEN
BRIDGE TO REMAIN
EXIST. ASPHALT
PATH TO REMAIN
EXIST. SILT FENCE
EXIST. SILT FENCE
PROP. SILT FENCE
SAWCUT EXIST. ASPHALT
REMOVE EXIST. ASPHALT
STA. 243+78.09 TO STA. 243+98.00
SAWCUT EXIST. ASPHALT
E
AS
T B
AY
B
LV
D
8'
11.5'11.5'
5.4'
6.1'
EXIST. 38.6 LF 30" RCP
TO BE REMOVED @1.58%
EXIST. CONCRETE
HEADWALL INV. 3.24'
EXIST. CONCRETE HEADWALL TO
BE REMOVED STATION 243+90.60
OFFSET 19.58' RT, INV. 3.85'EXIST. CONCRETE HEADWALL TO
BE REMOVED STATION 243+89.57
OFFSET 17.73' LT, INV. 3.24'
WETLANDS
FLOATING TURBIDITY
CURTAIN
EXIST. RIP-RAP TO BE
REMOVED AND RELOCATED
AS NEEDED
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
Feet 0 20 40
N
12 23
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
- D
EM
O
LI
TI
O N
P
LA
N C
D -9
CD X
Legend
-SF- Silt Fence
Cross Drain
Major Contour
Minor Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Wetlands
Floating Turbidity Curtain
CONTRACTOR NOTES
1.CONTRACTOR TO PROTECT ALL ITEMS UNLESS OTHERWISE NOTED TO BE REMOVED.
2. CONTRACTOR TO LOCATE ALL UTILITIES (HORIZONTAL AND VERTICAL LOCATIONS)
3. CONTRACTOR TO RELOCATE/REUSE EXISTING RIPRAP AS NEEDED.
4. ALL COSTS FOR CONSTRUCTION SHALL BE INCLUDED IN THE CONTRACTOR'S LUMP
SUM BID.
5.ALL EXCAVATED AND DISTURBED AREAS SHALL BE RESTORED WITH SOD.
6. SOD TYPE SHALL BE THE SAME AS EXISTING LAWN GRASS.
7. ZOYSIA OR APPROVED EQUAL SHALL BE USED WHERE EXISTING GRASS TYPE IS
NOT APPARENT, SOD ALL DISTURBED AREAS.
8. SOD ALL DISTURBED AREAS AND REPLACE DAMAGED LANDSCAPING AS NECESSARY
TO MATCH EXISTING SOD TYPE AND PRE-CONSTRUCTION CONDITION.
9. CONTRACTOR TO VERIFY REQUIRED QUANTITY FOR RIP-RAP APRONS.
QUANTITY OF RIP-RAP ONLY FOR CD-1.
AutoCAD SHX Text Engineers Surveyors Planners
POT STA. +32.49
18" FAIRPOINT REGIONAL
UTILITY WATERMAIN TO REMAIN
EXIST. GAS LINE TO REMAIN
6 5
5 6 7
3.00
3.85
CD 9EXIST. WOODEN
BRIDGE TO REMAIN
E
AS
T B
AY
B
LV
D
CONST. CONCRETE HEADWALL
STA. 243+90.60 OFFSET 26' RT
INV. EL.= 3.85'
8'
11.5'11.5'
14.5'
EXIST. ASPHALT PATH
TO REMAIN
CONST. SILT FENCE CONST. SILT FENCE
CONST. CONCRETE HEADWALL
STA. 243+89.57 OFFSET 26' LT
INV. EL.= 3.00'
CONST. 55 LF
30" RCP @ 1.6%
APPROXIMATE R/W
DD
REMOVE AND REINSTALL
RIPRAP AS NEEDED
SURVEY CONTROL POINT
NORTHING: 526868.187
EASTING: 1190047.146
ELEV. = 7.90'
441.16 SQ. FT. OF
WETLAND IMPACTS14.5'
APPROXIMATE R/W
EXIST. 12" WATERLINE
TO REMAIN
PROPOSED
30" RCP
EXISTING PIPE
(TO BE REMOVED)
PROP. CONC.
HEADWALL
INV.=3.00'
INV.=3.85'
PROP. CONC.
HEADWALL
441.16 SQ. FT. OF
WETLAND IMPACTS
EXIST. 12" WATERLINE
TO REMAIN
18" FAIRPOINT REGIONAL
UTILITY WATERMAIN
EXIST. GAS LINE TO REMAIN
1195300
SURVEY
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
Feet 0 20 40
N
13 23
PR
O
PO
SE
D C
U
LV
ER
T
PL
A
N C
D
-9CD X
Legend
-SF- Silt Fence
Cross Drain
Existing Major Contour
Existing Minor Contour
Proposed Contour
------ Edge of Pavement
------ Edge of Culvert
Power Pole
Control Point
Full-Depth Asphalt Reconstruction
Existing Wetlands
Impacted Wetlands
Floating Basin Boom
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
CL
AutoCAD SHX Text R/W
AutoCAD SHX Text R/W
AutoCAD SHX Text
EOS
AutoCAD SHX Text
EOS
AutoCAD SHX Text
SECTION D-D
AutoCAD SHX Text Engineers Surveyors Planners
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
14 23
C O
N
ST
R U
C
TI
O N
D
ET
A
IL
S H
EE
T
AutoCAD SHX Text Engineers Surveyors Planners
NUMBER
PROJECT
NUMBER
DRAWING
NUMBER
N U
M B
ER
R
EV
IS
IO
N
S
Z.
I.G
D R
A W
N B
Y
D A
TE
A
PP
R
O V
ED
B
Y
D
EC
EM
B
ER
D A
TE
FI
EL
D B
O O
K
PA
G
ES
M .J.
W
D A
TE
R
EG
. F
LA
. E N
G . N
O
D
ES
IG
N
ED
B
Y
SI
G
N A
TU
R
E:
C H
EC
K
ED
B
Y
SE
C
TI
O
N /T
O W
N
SH
IP
/R
A N
G E
, 1
8, 7, 8, 3/ T-
S/
R -2
7W
Q A
/Q C
M A
N A
G
ER
D
IS
TR
IC
T:
SHEET OF
C R
E A
ST
B
A Y
C U
LV
ER
T R
EP
LA
C
EM
EN
T
A
.V .H
4A .V
.H
TH
E
O
FF
IC
IA
L R
EC
O
R D
O F
TH
IS
S H
EE
T
IS
T
H E
EL
EC
TR
O
N
IC
F
IL
E D
IG
IT
A
LL
Y S
IG
N
ED
A
N D
S
EA
LE
D
U N
D
ER
R U
LE
1G
-2 3.
4, F .A
.C
15 23
C O
N
ST
R U
C
TI
O N
D
ET
A
IL
S H
EE
T
III
III
TYPE ITYPE II
AutoCAD SHX Text Engineers Surveyors Planners
AutoCAD SHX Text 215 FAIRPOINT DR SUITE B GULF BREEZE, FL 32561 Telephone (850) 512-8935
AutoCAD SHX Text
APPROVED BY THE ENGINEER.
AutoCAD SHX Text
THE USER. SUBSTITUTIONS FOR TYPES AND SHALL BE AS
AutoCAD SHX Text
RIGHTS OF THE DESIGNER SHALL BE THE SOLE RESPONSIBILITY OF
AutoCAD SHX Text
TO PROPRIETARY DESIGNS. ANY INFRINGEMENT ON THE PROPRIETARY
AutoCAD SHX Text
NOTICE: COMPONENTS OF TYPES AND MAY BE SIMILAR OR IDENTICAL
AutoCAD SHX Text D =5' Std. (Single Panel For Depths 5' or Less).
AutoCAD SHX Text 18 Oz. Nylon Reinforced PVC Fabric (300 psi Test) With Lacing Grommets
AutoCAD SHX Text Per Ft. Buoyancy)
AutoCAD SHX Text Flotation (6" Dia. Equiv.) (12 Lbs.
AutoCAD SHX Text Closed Cell Solid Plastic Foam
AutoCAD SHX Text Flotation (8" Dia. Equiv.) (17 lbs.
AutoCAD SHX Text Per Ft. Buoyancy)
AutoCAD SHX Text Closed Cell Solid Plastic Foam
AutoCAD SHX Text (9800 Lbs. Breaking Strength) With
AutoCAD SHX Text 5/16" Vinyl Sheathed EAW Steel Cable
AutoCAD SHX Text 5/8" Polypro Rope (600 lb. Breaking Strength)
AutoCAD SHX Text D =5' Std. (Additional Panel For Depths > 5').
AutoCAD SHX Text 18 Oz. Nylon Reinforced PVC Fabric (300 psi Test)
AutoCAD SHX Text Galvanized Connectors (Tool Free Disconnect)
AutoCAD SHX Text Slotted PVC Connector Pipe (Metal Collar Reinforced)
AutoCAD SHX Text For In The Plans Or As…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .