RFB943500-01 - HCR Roof Replacement - Drawings.pdf
PDF 7 MB Posted
- Attached to
- Honey Creek Resort Hotel Roof Replacement & AHU
- Solicitation number
- RFB943500-01
- Issued by
- Adams County, Iowa
About this file
These construction documents detail a comprehensive roof replacement project for the Honey Creek Resort Lodge located at 12633 Resort Dr, Moravia, Iowa 52571. The project involves replacing roof systems across multiple building areas (A, B1, B2, C1, and C2) using asphalt shingles, with two primary alternates: Alternate No. 1 covers roof replacement for Areas B1 and B2, while Alternate No. 2 involves adding new gutters and downspouts to those same areas. The project includes removing existing roofing materials, potentially replacing up to 3,200 square feet of plywood sheathing, installing new roofing underlayment, ice and dam protection membrane, asphalt shingles, ridge vents, and reinstalling existing solar panels.
The project documents, prepared by Farnsworth Group and dated March 10, 2025, provide detailed mechanical and architectural plans for a 100% construction document set. The mechanical scope includes removing and replacing RTU-3 (Rooftop Unit 3), reconnecting gas lines, and rebalancing existing diffusers. The roof replacement will maintain existing roof slopes and drainage patterns, with specific requirements for slope, ventilation, and flashing. The project includes provisions for protecting existing structures, coordinating with mechanical and electrical systems, and ensuring a complete, warrantable roofing system that meets manufacturer and National Roofing Contractors Association (NRCA) requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALIGN
GLAZING TYPE
ROOF PITCH
DOOR NUMBER
CEILING/ SOFFIT
HEIGHT
MATL
1'-0"
-1
SLOPE: 1/4"
SLOPE/ROOF SLOPE
WALL SECTION
INTERIOR ELEVATION
COLUMN GRID
ELEVATION
REVISION NOTE
ENLARGED CALLOUT
ROOM DESIGNATION
BREAK LINE
DETAIL #
SHEET #
DETAIL #
SHEET #
A8.1
EXTERIOR ELEVATION
DETAIL #
SHEET #
A8.1
A8.1
A8.1
BUILDING SECTION
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
DETAIL #
SHEET #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
XX.X
ELEVATION
0'-0"
0"
-6" CHANGE IN LEVEL
ALIGN
ARCHITECTURE
ROOM
NAME
CASEWORK TYPE AL1
DEMOLITION KEYNOTE
TOILET ACCESSORY
WALL TYPE
KEYNOTE#.#
D#.#
T#
B#
SYMBOLS LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS
ABBREVIATIONS
CL
INSUL INSULATION
JT JOINT
L/S LANDSCAPE
LB(S) POUND(S)
LF LINEAR FEET (FOOT)
LT LIGHT
LTTR LONG-TERM THERMAL
RESISTANCE
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFCR OWNER FURNISHED,
CONTRACTOR ROUGH-IN
OFOI OWNER FURNISHED,
INSTALLED BY OTHERS
O TO O OUT TO OUT
OPNG OPENING
OPP OPPOSITE
OVHD OVERHEAD
PERIM PERIMETER
PFIN PREFINISHED
PL PLATE
PLYWD PLYWOOD
PNT PAINT
PR PAIR
PT PRESSURE TREATED
PTD PAINTED
PWR POWER
RAD RADIUS
REC RECESSED
REINF REINFORCED
REQ'D REQUIRED
REV REVISED (REVISION)
RD ROOF DRAIN
RM ROOM
RO ROUGH OPENING
S SOUTH
SB SPLASH BLOCK
SF SQUARE FEET (FOOT)
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD(S)
T/O TOP OF
T&G TONGUE AND GROOVE
TRTD TREATED
TYP TYPICAL
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
W WEST
WD WOOD
WH WATER HEATER
WT WEIGHT
GENERAL
ADJ ADJUSTABLE
ADT'L ADDITIONAL
AFF ABOVE FINISHED FLOOR
AGG AGGREGATE
ALT ALTERNATE
AL ALUMINUM
APPROX APPROXIMATE(LY)
ASPH ASPHALT
AUTO AUTOMATIC
B/O BOTTOM OF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRG BEARING
CENTERLINE
C/C CENTER TO CENTER
CEM CEMENT(ITIOUS)
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED,
INSTALLED BY OTHERS
CJ CONTROL JOINT
CLL CONTRACT LIMIT LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CTR CENTER(ED)
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DET/DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWG(S) DRAWING(S)
E EAST
EA EACH
EC ELECTRICAL CONTRACTOR
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EX/EXIST EXISTING
EXJ EXPANSION JOINT
EXP EXPOSED
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FFE FINISH FLOOR ELEVATION
FIN FINISH
FLSHG FLASHING
FLR FLOOR
FRMG FRAMING
FT FOOT/FEET
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
HOR HORIZONTAL
HT HEIGHT
HVAC HEATING/VENTILATION/AIR
CONDITIONING
ID INSIDE DIAMETER
IN INCH
INCL INCLUDING
GROUP
G R
O U
P
PROJECT NO.: DATE:
LOCATION MAP
IMAGE © < COPYRIGHT NOTICE >
14225 University Avenue, Suite 110 - Waukee, Iowa 50263 - Phone: (515) 225-3469 / info@f-w.com
/1
/2
:2 :0
P
M
0241298.00
HONEY CREEK RESORT -
LODGE ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
D A
S P
R O
J E
C T
.0
100% CD SET
H O
N E
Y C
R E
E K
R E
S O
R T
L O
D G
E R
O O
F R
E P
L A
C E
M E
N T
DRAWING LIST
*CO COVER
ARCHITECTURAL
A0.1 GENERAL INFORMATION
A2.1 ROOF PLAN
A2.2 ROOF PLAN - AREAS A AND B1
A2.3 ROOF PLAN - AREAS B2 AND C1
A2.4 ROOF PLAN - AREA C2
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A3.3 EXTERIOR ELEVATIONS
A3.4 EXTERIOR ELEVATIONS
A3.5 EXTERIOR ELEVATIONS
A7.1 ROOF DETAILS
MECHANICAL
MD1.1 FIRST FLOOR MECHANICAL DEMOLITION PLAN
M0.1 GENERAL INFORMATION
M1.1 FIRST FLOOR MECHANICAL PLAN
12633 Resort Dr, Moravia, Iowa 52571
PAGES OR DIVISIONS COVERED:
LICENSE RENEWAL DATE:
DATE:
NAME:
SIGNATURE:
THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW
WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL
SUPERVISION. I AM A DULY LICENSED ENGINEER UNDER THE
LAWS OF THE STATE OF IOWA.
PAGES OR DIVISIONS COVERED:
LICENSE RENEWAL DATE:
DATE:
NAME:
SIGNATURE:
THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW
WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL
SUPERVISION. I AM A DULY LICENSED ARCHITECT UNDER THE
LAWS OF THE STATE OF IOWA.
Wade C. Ross
03/10/2025
12/31/2025
All "M" Series Sheets
M0.1 GENERAL INFORMATION
MD1.1 FIRST FLOOR MECHANICAL DEMOLITION PLAN
Sarah L. Huston
03/10/2025
06/30/2026
A-Series Sheets
DRAWING LIST
*CO COVER
ARCHITECTURAL
AD2.1 ROOF DEMOLITION PLAN
A2.1 ROOF PLAN
A2.2 ROOF PLAN - AREAS A AND B1
A2.3 ROOF PLAN - AREAS B2 AND C1
A2.4 ROOF PLAN - AREA C2
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A3.3 EXTERIOR ELEVATIONS
A3.4 EXTERIOR ELEVATIONS
A3.5 EXTERIOR ELEVATIONS
A7.1 ROOF DETAILS
A7.2 ROOF DETAILS
MECHANICAL
MD1.1 FIRST FLOOR MECHANICAL DEMOLITION PLAN
M0.1 GENERAL INFORMATION
M1.1 FIRST FLOOR MECHANICAL PLAN
M0.1 GENERAL INFORMATION
MD1.1 FIRST FLOOR MECHANICAL DEMOLITION PLAN
A. EXISTING CONSTRUCTION SHOWN DASHED IS TO BE DEMOLISHED – COORDINATE WITH NEW CONSTRUCTION
B. ALL ITEMS INDICATED TO BE DEMOLISHED SHALL BE REMOVED AS TO FULLY ALLOW FOR THE PROPER FURNISHING AND INSTALLATION OF ALL SCHEDULED NEW WORK. THIS SHALL INCLUDE DEMOLITION OF ADJACENT ITEMS, ACCESSORIES, AND APPURTENANCES AS
NECESSARY.
C. DEMOLITION DRAWINGS ILLUSTRATE MAJOR ITEMS TO BE REMOVED. CONTRACTOR SHALL COORDINATE THESE DRAWINGS WITH NEW WORK DRAWINGS AND SHALL BE RESPONSIBLE FOR OTHER ITEMS REQUIRED TO BE DEMOLISHED TO ACCOMMODATE NEW WORK.
D. THE CONTRACTOR IS RESPONSIBLE FOR RETAINING AND RELOCATING ALL SALVAGE AS DESIGNATED BY THE OWNER'S
REPRESENTATIVE.
E. THE CONTRACTOR IS RESPONSIBLE FOR STORAGE AND PROTECTION OF ALL SALVAGE ITEMS.
F. EXISTING ITEMS, EQUIPMENT, ROOF PENETRATIONS, ETC, TO REMAIN IN PLACE SHALL BE PROTECTED FROM DIRT AND DAMAGE DURING
DEMOLITION AND CONSTRUCTION.
G. PROTECT ALL FINISHES TO REMAIN FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.
H. PRIOR TO DEMOLITION, ENSURE THE STABILITY OF ANY STRUCTURE TO REMAIN.
I. REMOVAL OF EXISTING HVAC TO INCLUDE DUCTWORK, HANGERS, GRILLES, DIFFUSERS, ETC. SEE MECHANICAL DRAWINGS.
J. REMOVAL OF EXISTING ELECTRICAL SYSTEMS TO INCLUDE CONDUIT, BOXES, WIRE, CABLE, SUPPORTS, WIRING DEVICES, SAFETY SWITCHES, FIRE ALARM EQUIPMENT, SPEAKERS, TELEPHONE OUTLETS AND LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS.
K. HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO; ASBESTOS AND/OR LEAD PAINT, IS ENCOUNTERED ON THE PROJECT SITE, THE OWNER SHALL ENGAGE A TESTING COMPANY TO IDENTIFY AREAS AND PROVIDE APPROPRIATE ABATEMENT. DEMOLITION
CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH ABATEMENT CONTRACTOR.
DEMOLITION GENERAL NOTES
EXISTING SOLAR PANELS
- REMOVE AND SALVAGE FOR
REINSTALLATION
ALTERNATE NO. 1 - DEMOLISH ALL EXISTING ASPHALT SHINGLE ROOF SYSTEM
DEMOLISH ALL EXISTING ASPHALT
SHINGLE ROOF SYSTEM
DEMOLISH MEMBRANE ROOF
AND PREP TO RECEIVE NEW
ROOF - COORDINATE SCOPE
WITH NEW WORK
DEMO EXISTING GUTTERS
AND DOWNSPOUTS @ AREA A
DEMO EXISTING GUTTERS AND
DOWNSPOUTS @ AREA A
ALTERNATES NO. 1 AND NO. 2
A L
T E
R N
A T
E S
N O
A
N D
N O
DEMOLISH ALL EXISTING ASPHALT
SHINGLE ROOF SYSTEM
REMOVE DETERIORATED
PLYWOOD SUBSTRATE -
CONTRACTOR TO VERIFY
EXTENTS OF DAMAGE
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING
CONSTRUCTION (TYPICAL)
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING
CONSTRUCTION (TYPICAL)
ALTERNATE NO. 2 - ADDITIONAL
GUTTER AND DOWNSPOUTS FOR
AREAS B1 & B2 COORDINATE
WITH EXTERIOR ELEVATIONS
ALTERNATE NO. 2 - ADDITIONAL
GUTTER AND DOWNSPOUTS FOR
AREAS B1 & B2 COORDINATE
WITH EXTERIOR ELEVATIONS
ALTERNATE NO. 2 - ADDITIONAL
GUTTER AND DOWNSPOUTS FOR
AREAS B1 & B2 COORDINATE
WITH EXTERIOR ELEVATIONS
ALTERNATE NO. 2 - ADDITIONAL GUTTER AND DOWNSPOUTS
FOR AREAS B1 & B2 COORDINATE WITH EXTERIOR ELEVATIONS
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING
CONSTRUCTION (TYPICAL)
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN PROTECT
DURING CONSTRUCTION (TYPICAL)
DEMO EXISTING GUTTERS
AND DOWNSPOUTS @ AREA A
A. ALTERNATE NO 1:
ROOF REPLACEMENT OF AREAS B1 AND B2.
A. ALTERNATE NO 2:
ADDITIONAL GUTTERS AND DOWNSPOUTS ON AREAS B1 AND B2
ALTERNATES
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M AD2.1
ROOF DEMOLITION
PLAN
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 3/64" = 1'-0"
ROOF DEMOLITION FLOOR PLAN 0 84 16
NORTH
PLAN
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
C1B1
NOTE:
AREAS B1 AND B2: SEE ALTERNATES NO. 1 AND NO. 2 FOR SCOPE OF WORK
K. ROOF CONTRACTOR SHALL PROVIDE ALL TEMPORARY WEATHER PROTECTION
NECESSARY TO MAINTAIN A WATERTIGHT BUILDING INTERIOR THROUGHOUT
CONSTRUCTION.
L. ALL ROOF PENETRATIONS TO BE IN COMPLIANCE WITH MANUFACTURER AND NRCA
REQUIREMENTS.
M. PROVIDE NEW FLASHING FOR ALL VENT PIPES AND ROOF PENETRATIONS.
N. ROOFING COMPONENTS MAY VARY DEPENDING ON ROOFING MANUFACTURER.
CONTRACTOR SHALL INSTALL A COMPLETE CODE COMPLIANT AND WARRANTIED
ROOFING SYSTEM BASED ON THE SPECIFIED ROOFING MANUFACTURERS WRITTEN
INSTRUCTIONS AND INSTALLATION GUIDELINES.
O. PROVIDE MINIMUM 15’-0” CLEARANCE FROM ANY INTAKE FOR ALL EQUIPMENT AND
VENT STACKS. ALERT DESIGN PROFESSIONAL OF ANY CONFLICTS PRIOR TO
CONSTRUCTION.
P. ONCE ROOF WORK BEGINS, THE CONTRACTOR IS ACCEPTING ALL CONDITIONS AND
WILL BE RESPONSIBLE FOR ALL DEMOLITION AND NEW WORK REQUIRED TO
PROVIDE A WATERTIGHT ROOF SYSTEM.
Q. EXISTING GUTTERS AND DOWNSPOUTS SHALL REMAIN EXCEPT WHERE INDICATED.
REMOVE, SALVAGE, AND REINSTALL AS REQUIRED FOR NEW WORK.
R. THE CONTRACTOR SHALL ENSURE THAT UPON COMPLETION OF ROOF WORK, ALL
GUTTERS, DOWNSPOUTS AND ROOF DRAINS ARE CLEAN AND CLEAR OF DEBRIS TO
PROVIDE AN UNOBSTRUCTED, FREE FLOW OF WATER.
S. EXISTING SLOPED ROOF SYSTEM AT AQUATIC CENTER IS A VENTILATED INSULATION
SYSTEM. IF SHEATHING REPLACEMENT IS REQUIRED THE NEW SHEATHING AND
ASSOCIATED BLOCKING SHALL MATCH THE PROPERTIES OF THE EXISTING SYSTEM.
T. REPLACEMENT OF INSULATED VENTILATION BLOCKING SPACING SHALL MEET
PRODUCT REQUIREMENTS AND NEGATE SAG/SOFT SPOTS.
ROOF GENERAL NOTES
A. ALL DIMENSIONS AND SLOPES SHALL BE FIELD VERIFIED.
B. ALL ROOF SURFACES TO SLOPE AT A MINIMUM 1/4" PER FOOT UNLESS OTHERWISE
NOTED OR SHOWN.PROVIDE TAPERED INSULATION WHERE INDICATED OR REQUIRED
TO PROVIDE POSITIVE DRAINAGE TO ROOF DRAINS AT A MINIMUM 1/4" PER FOOT.
TAPERED INSULATION LAYOUT AS SHOWN IS TO COMMUNICATE GENERAL DRAIN
STRATEGY - ACTUAL AMOUNT MAY VARY.
C. ALL ROOF AREAS MUST HAVE POSITIVE DRAINAGE UNLESS SHOWN OTHERWISE. NO
PONDING OF WATER OVER 1/8" IN DEPTH WILL BE ACCEPTABLE AT ROOF DRAINS.
D. MAINTAIN ALL EXISTING ROOF SLOPES AND ROOF DRAIN LOCATIONS. NEW
COVERBOARD SHALL BE INSTALLED AS NOT TO DISRUPT EXISTING ROOF SLOPES OR
CRICKETS.
E. ALL ROOF MOUNTED MECH UNITS SHALL REMAIN IN PLACE UNLESS NOTED
OTHERWISE.
F. LOCATE AND PROTECT ALL EXISTING ROOF MOUNTED PIPING, GAS LINES, AND
ELECTRICAL CONDUIT.
G. CONTRACTOR SHALL VISUALLY INSPECT ALL EXISTING SUBSTRATE ONCE EXISTING
SHINGLES/MEMBRANE ARE REMOVED, AND REPORT ANY EVIDENCE OF WATER OR
LEAKS.
H. INCLUDE REMOVAL AND REPLACEMENT OF 3,200SF OF SHEATHING IN QUOTE FOR
ANY POTENTIAL PLYWOOD SHEATHING REPAIR THAT IS REQUIRED FOR NEW
CONSTRUCTION. SEE SPECS AND BID FOR FOR MORE INFORMATION.
I. PROVIDE UNIT PRICE PER SHEET FOR POTENTIAL PLYWOOD SHEATHING REPLAIR
BEYOND ALLOWANCE.
J. COORDINATE ALL ROOF PENETRATION REQUIREMENTS, INCLUDING THOSE THAT
MAY NOT BE SHOWN, WITH ROOFING CONTRACTOR, AND MECHANICAL/ELECTRICAL
DRAWINGS.
A3.2
A3.5
A3.1
A3.1
A3.2
A3.4
A3.
A3.
A3.
A3.
A3.3
ROOF - ASPHALT SHINGLES
(TYPICAL)
ROOF - ASPHALT SHINGLES
(TYPICAL)
ROOF - ASPHALT SHINGLES
(TYPICAL)
SALVAGE AND REINSTALL
EXISTING SOLAR PANELS
ROOF - EPDM
MEMBRANE ROOF
EXISTING MEMBRANE
ROOF TO REMAIN
ROOF - ASPHALT SHINGLES
(TYPICAL)
ROOF - ASPHALT SHINGLES
(TYPICAL)
ALTERNATES NO. 1 AND NO. 2
NEW 5x5 GUTTER
4"x5" PREFINISHED CLOSED
FACE DOWNSPOUT
DN
DN
DN
DN
DNDN
DN
DN
DN
DN
NEW 5x5 GUTTER
A L
T E
R N
A T
E S
N O
A
N D
N O
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
DN DN DN DN DN DN DN DN DN DN DN DN
DNDNDNDNDNDNDNDN
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
ROOF CURB INFILL
ALTERNATE NO. 1 - ROOF -
ASPHALT SHINGLES (TYPICAL)
ALTERNATE NO. 1 - ROOF -
ASPHALT SHINGLES (TYPICAL)
ALTERNATE NO. 1 - ROOF -
ASPHALT SHINGLES (TYPICAL)
4"x5" PREFINISHED
CLOSED FACE
DOWNSPOUT
ROOF - ASPHALT SHINGLES
(TYPICAL)
ROOF - ASPHALT SHINGLES
(TYPICAL)
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
CRICKETED AREA MINIMUM 1/2:12 SLOPE
INDICATES ROOF SLOPE/PITCH
NEW RIDGE VENT
WALL BELOW
SLOPE: 1/4"
ROOF PLAN LEGEND
A. ALTERNATE NO 1:
ROOF REPLACEMENT OF AREAS B1 AND B2.
A. ALTERNATE NO 2:
ADDITIONAL GUTTERS AND DOWNSPOUTS ON AREAS B1 AND B2
ALTERNATES
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :5
P
M A2.1
ROOF PLAN
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
0 84 16
NORTH
PLAN
SCALE: 3/64" = 1'-0"
ROOF PLAN
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
C1B1
A3.2
A3.5
A3.1
A3.1
10" / 12" 10" / 12"
10" / 12" 10" / 12"
10" / 12" 10" / 12"
5" / 12"
5" / 12"
5" / 12"
5" / 12"
3" / 12" 3" / 12"
5" / 12"
5" / 12"
"1
10" / 12" 10" / 12"
10" / 12"10" / 12"10" / 12"10" / 12"
10" / 12" 10" / 12"
10" / 12" 10" / 12"
11'-9" 13'-11" 18'-6" 23'-6" 18'-6" 13'-11" 8'-4" 13'-11" 18'-6" 13'-4" 24'-10" 13'-4" 18'-6" 13'-11" 8'-1"
33'-0" 23'-9" 33'-0"
11'-9" 88'-4" 8'-4" 116'-4" 8'-1"
10" / 12"10" / 12" 10" / 12"10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12"10" / 12" 10" / 12"10" / 12"10" / 12"10" / 12" 10" / 12"10" / 12"10" / 12"
10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12"
88'-4" 116'-4"
13'-11" 18'-7" 13'-3" 24'-10" 13'-3" 18'-7" 13'-11"3'-9" 10'-2" 18'-7" 10'-1" 3'-2" 10'-1" 18'-7" 10'-2" 3'-9"
A3.2
A7.1
A7.1
A7.1
REMOVE AND REINSTALL
EXISTING SOLAR PANELS AT
SAME LOCATION
REMOVE AND REINSTALL
EXISTING SOLAR PANELS AT
SAME LOCATION
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTION MEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTIONMEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTION MEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
NEW SHINGLES OVER ROOFING UNDERLAYMENT -
INSTALL SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE - EXTEND 2' MINIMUM BEYOND INSIDE
FACE OF WALL BELOW (TYPICAL)
A7.1
A7.1
A7.1
EXISTING ROOF
PENETRATION EXISTING ROOF
PENETRATION
EXISTING ROOF
PENETRATION EXISTING ROOF
PENETRATION
A7.1
A7.1
A7.1
A7.1
A7.1
NEW SHINGLES OVER
ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE
AND DAM PROTECTION
MEMBRANE ON EXISTING
PLYWOOD ROOF
SHEATHING - INSTALL SELF-
ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF
3:12 SLOPED ROOF
NEW SHINGLES OVER
ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE
AND DAM PROTECTION
MEMBRANE ON EXISTING
PLYWOOD ROOF
SHEATHING - INSTALL SELF-
ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF
3:12 SLOPED ROOF
DS
DS
DS DS DS
DS
10" / 12"10" / 12"10" / 12"10" / 12"
10" / 12" 10" / 12" 10" / 12" 10" / 12"
A7.2
A L
T E
R N
A T
E S
N O
A
N D
N O
ALTERNATES NO. 1 AND NO. 2
NEW 5x5 GUTTER
4"x5" PREFINISHED CLOSED
FACE DOWNSPOUT
NEW 5x5 GUTTER
DN
DN
DN
DN
DNDN
DN
DN
DN
DN
B A
S E
-B
ID
DN DN DN DN DN DN DN DN DN
DNDNDNDNDN
ALTERNATE NO. 2 - NEW PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS TO REMAIN (TYPICAL)
A7.2
A7.2
A7.2
A7.2
RIDGE VENT
(TYPICAL)
RIDGE VENT
(TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS TO REMAIN (TYPICAL)
RIDGE VENT
(TYPICAL)
4"x5" PREFINISHED CLOSED
FACE DOWNSPOUT
NEW 5x5 GUTTER
NEW 5x5 GUTTER
SIM.
SIM.
NEW SOFFIT CONTINUOUS
INTAKE VENT
NEW SOFFIT CONTINUOUS
INTAKE VENT
NEW SOFFIT CONTINUOUS
INTAKE VENT
NEW SOFFIT CONTINUOUS
INTAKE VENT
NEW SOFFIT CONTINUOUS
INTAKE VENT
NEW SOFFIT CONTINUOUS
INTAKE VENT
ALTERNATE NO. 2 - NEW PREFINISHED DOWNSPOUTS TO
MATCH EXISTING DOWNSPOUTS TO REMAIN (TYPICAL)
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :5
P
M A2.2
ROOF PLAN - AREAS
A AND B1
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 3/32" = 1'-0"
ROOF PLAN - AREA A AND AREA B1 (ALTERNATES NO. 1 AND NO. 2)
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
NOTE:
AREAS B1 AND B2: SEE ALTERNATES NO. 1 AND NO. 2 FOR SCOPE OF WORK
0 84 16
NORTH
PLAN
10" / 12"10" / 12"
10" / 12"10" / 12"10" / 12"10" / 12"10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12" 10" / 12"
10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12"10" / 12"10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12"10" / 12"
10" / 12"
10" / 12" 10
2"
2"
10" / 12"
10" / 12"10
2"
2"
8'-1" 88'-4" 13'-6" 80'-0"
12'-0" 12'-0"
44'-0"
13'-11" 18'-6" 23'-6" 18'-6" 13'-11"
13'-6" 80'-0"
13'-10" 18'-7" 23'-5" 18'-7" 14'-0"
8'-1" 88'-4"
30'-0" 20'-0" 30'-0"
A3.4
A3.3
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTION MEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTION MEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
NEW SHINGLES OVER ROOFING UNDERLAYMENT -
INSTALL SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE - EXTEND 2' MINIMUM BEYOND INSIDE
FACE OF WALL BELOW (TYPICAL)
A7.1
A7.1
EXISTING ROOF
PENETRATION
EXISTING ROOF
PENETRATION
A7.1
A7.1 _____8
A7.1
A7.1
A7.1
A7.1
A7.2
ALTERNATE NO. 2 - NEW
PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS TO
REMAIN (TYPICAL)
ALTERNATES NO. 1 AND NO. 2
BASE-BID
DN DN DN DN
DNDNDNDN
ALTERNATE NO. 2 - NEW
PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
RIDGE VENTS
(TYPICAL)
NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-
ADHERING ICE AND DAM
PROTECTION MEMBRANE - EXTEND
2' MINIMUM BEYOND INSIDE FACE
OF WALL BELOW (TYPICAL)
RIDGE VENTS
(TYPICAL)
ALTERNATE NO. 2 - NEW
PREFINISHED DOWNSPOUT TO
MATCH EXISTING DOWNSPOUTS
TO REMAIN (TYPICAL)
NEW SHINGLES OVER ROOFING
UNDERLAYMENT
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A2.3
ROOF PLAN - AREAS
B2 AND C1
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 3/32" = 1'-0"
ROOF PLAN - AREA B2 (ALTERNATES NO. 1 AND NO. 2) AND AREA C1
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
NOTE:
AREAS B1 AND B2: SEE ALTERNATES NO. 1 AND NO. 2 FOR SCOPE OF WORK
0 84 16
35'-0"27'-2"6'-11"28'-6"12'-1"28'-6"12'-0"27'-2"16'-0"
193'-3"
10" / 12" 10" / 12"
/2
/2
10" / 12" 10" / 12"
5" / 12"
5" / 12"
5" / 12"
5" / 12"
5"
5"
10" / 12"
10" / 12"
104'-11"104'-8"
209'-6"
19'-0"
A3.3
A3.3
A3.4
A3.4
17'-0"
EPDM MEMBRANE OVER
1/2" COVERBOARD
EXISTING MEMBRANE
ROOF TO REMAIN
NEW SHINGLES OVER ROOFING UNDERLAYMENT - INSTALL
SELF-ADHERING ICE AND DAM PROTECTION MEMBRANE -
EXTEND 2' MINIMUM BEYOND INSIDE FACE OF WALL BELOW
(TYPICAL)
NEW SHINGLES OVER ROOFING UNDERLAYMENT
- INSTALL SELF-ADHERING ICE AND DAM
PROTECTION MEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
NEW SHINGLES OVER ROOFING
UNDERLAYMENT
- INSTALL SELF-ADHERING ICE AND DAM
PROTECTION MEMBRANE - EXTEND 2'
MINIMUM BEYOND INSIDE FACE OF WALL
BELOW (TYPICAL)
A7.1
A7.2
A7.2
A7.2
A7.2
A7.2
A7.2
A7.2
A7.1 _____1
A7.1
A7.1 _____2
A7.1
A7.1
A7.1
A7.1
A7.2
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER
SELF-ADHERING ICE AND DAM PROTECTION MEMBRANE
ON EXISTING PLYWOOD ROOF SHEATHING - INSTALL
SELF-ADHERING ICE AND DAM MEMBRANE ON
ENTIRETY OF 2 1/2:12 SLOPED ROOF
52'-0"
1/4" / 12"
1/4" / 1 2"
1/4" / 12"
1/4" / 12"
1/2"
1/2"
CRICKET WITH 1/2" SLOPE AWAY
FROM EXISTING ROOF HATCH
CRICKET WITH 1/2"
SLOPE AWAY FROM
EXISTING ROOF CURB
EXISTING EQUIPMENT
REMOVE AND REPLACE
PLYWOOD SHEATHING
APPROX. LOCATION SHOWN
REMOVE AND REPLACE
PLYWOOD SHEATHING
APPROX. LOCATION
SHOWN
NEW RTU ON NEW ROOF
CURB - SEE MECH DWGS
ACHIEVE SLOPE WITH
TAPERED INSULATION
ROOF WALK-PADS
- SEE SPECIFICATIONS
INSTALL ICE AND DAM
PROTECTION MEMBRANE OVER
THIS ENTIRE ROOF PLANE
INSTALL ICE AND DAM
PROTECTION MEMBRANE OVER
THIS ENTIRE ROOF PLANE
A7.2
ROOF CURB INFILL
RIDGE VENT
(TYPICAL)
RIDGE VENT
(TYPICAL)
RIDGE VENT
(TYPICAL)
EXISTING ROOF DRAIN
ACHIEVE SLOPE WITH
TAPERED INSULATION
NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-
ADHERING ICE AND DAM
PROTECTION MEMBRANE - EXTEND
2' MINIMUM BEYOND INSIDE FACE
OF WALL BELOW (TYPICAL)
RIDGE VENT
(TYPICAL)
A7.2
PROVIDE ADDITIONAL REINFORCING TO
EXISTING TRUSSES WHERE SHEATHING
IS REPLACED - AT THIS LOCATION
PROVIDE ADDITIONAL
REINFORCING TO EXISTING
TRUSSES WHERE SHEATHING IS
REPLACED - AT THIS LOCATION
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION
EXISTING GUTTERS AND DOWNSPOUTS TO
REMAIN - PROTECT DURING CONSTRUCTION
EXISTING GUTTERS AND DOWNSPOUTS TO
REMAIN - PROTECT DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
EXISTING GUTTERS AND DOWNSPOUTS TO
REMAIN - PROTECT DURING CONSTRUCTION
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A2.4
ROOF PLAN - AREA
C2
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 3/32" = 1'-0"
ROOF PLAN - AREA C2
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
NOTE:
AREAS B1 AND B2: SEE ALTERNATES NO. 1 AND NO. 2 FOR SCOPE OF WORK
0 84 16
B.O. ROOF
±29'-9"
B.O. ROOF
±9'-7"
LOWER LEVEL
-10'-0"
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE
AND DAM PROTECTIONMEMBRANE - EXTEND 2'
MINIMUM BEYOND INSIDE FACE OF WALL BELOW
(TYPICAL)
NEW SHINGLES OVER ROOFING UNDERLAYMENT -
INSTALL SELF-ADHERING ICE AND DAM
PROTECTIONMEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
A7.1
A7.1
10" / 12" 10" /
2"
5" / 1 2"
5" / 1 2" 5" / 12"
A7.1
A7.1
A7.2
NEW 5x5 PREFINISHED
METAL GUTTER
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
NEW 5x5 PREFINISHED
METAL GUTTER
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
RIDGE VENT (TYPICAL)
A7.1
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
RIDGE VENT (TYPICAL)
A7.1
B.O. ROOF
±41'-6"
A7.1
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
B.O. ROOF
±9'-1"
LOWER LEVEL
-10'-0"
B.O. ROOF
±29'-4"
B.O. ROOF
±32'-8"
B.O. ROOF
±41'-2"
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND DAM
PROTECTIONMEMBRANE - EXTEND 2' MINIMUM BEYOND INSIDE
FACE OF WALL BELOW (TYPICAL)
A7.1
A7.2
10" /
2" 10" / 12"
10" / 12"10" /
2" 5" / 12"5" / 1
2"
10" / 12"10" /
2"
10" /
2" 10" / 12"
3" / 12"
5" / 1 2"
5" / 12"
3" / 12"
REINSTALL SALVAGED SOLAR
PANELS AT SAME LOCATIONS
A7.1
NEW 5x5 PREFINISHED
METAL GUTTER
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
NEW 5x5 PREFINISHED
METAL GUTTER
RIDGE VENT (TYPICAL)
A7.1
A7.1
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAIL 5/A7.2 (TYPICAL
ON AREAS B1 AND B2)
A7.2
NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-
ADHERING ICE AND DAM
PROTECTIONMEMBRANE -
EXTEND 2' MINIMUM BEYOND
INSIDE FACE OF WALL BELOW
(TYPICAL)
A7.2
SIM.
NEW CONTINUOUS
SOFFIT VENTS
NEW CONTINUOUS
SOFFIT VENTS
EXISTING GUTTERS AND
DOWNSPOUTS TO
REMAIN - PROTECT
DURING CONSTRUCTION
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A3.1
EXTERIOR
ELEVATIONS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 1/8" = 1'-0"
AREA - A AND B1 SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
AREA - A AND B1 WEST ELEVATION
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
A7.1
A7.1
A7.1
B.O. ROOF
±29'-4"
LOWER LEVEL
-10'-0"
B.O. ROOF
±35'-4"
B.O. ROOF
±41'-2"
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTIONMEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
A7.1
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTIONMEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
A7.1
10" /
2" 10" / 12"
10" / 12"10" /
2"
10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" /
2" 10" / 12"
10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" / 12"10" /
2"
10" /
2" 10" / 12" 10" /
2" 10" / 12"
REINSTALL SALVAGED SOLAR
PANELS IN SAME LOCATION
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
DOWNSPOUT TO MATCH EXISTING
DOWNSPOUT TO REMAIN (TYPICAL) - TIE
NEW DOWNSPOUT INTO EXISTING - MODIFY
AS REQUIRED TO MAKE CONNECTION)
ALTERNATE NO. 2 - NEW PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
DOWNSPOUT TO MATCH EXISTING
DOWNSPOUT TO REMAIN (TYPICAL) - TIE
NEW DOWNSPOUT INTO EXISTING - MODIFY
AS REQUIRED TO MAKE CONNECTION)
A7.2
RIDGE VENT
(TYPICAL)
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAILS 5/A7.2
(TYPICAL ON AREAS B1 AND B2)
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAILS 5/A7.2
(TYPICAL ON AREAS B1 AND B2)
RIDGE VENT
(TYPICAL)
RIDGE VENT
(TYPICAL)
A7.2
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
DOWNSPOUT SHALL
NOT BLOCK EXISTING
VENTS (TYPICAL)
DOWNSPOUT SHALL
NOT BLOCK EXISTING
VENTS (TYPICAL)
B.O. ROOF
±9'-1"
LOWER LEVEL
-10'-0"
B.O. ROOF
B.O. ROOF
B.O. ROOF
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER SELF-
ADHERING ICE AND DAM PROTECTION MEMBRANE ON EXISTING
PLYWOOD ROOF SHEATHING - INSTALL SELF-ADHERING ICE AND
DAM MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
5" / 1 2" 5" / 12"
A7.1
A7.2
NEW 5x5 PREFINISHED
METAL GUTTER
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
NEW 4"x5" PREFINISHED
CLOSED FACE DOWNSPOUT
RIDGE VENT
(TYPICAL)
A7.1
EXISTING GUTTERS AND DOWNSPOUTS TO
REMAIN - PROTECT DURING CONSTRUCTION
SCALE: 1/8" = 1'-0"
AREA - A EAST ELEVATION
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A3.2
EXTERIOR
ELEVATIONS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 1/8" = 1'-0"
AREA - B1 AND B2 SOUTH ELEVATION (ALTERNATES NO. 1 AND NO. 2)
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
±8'-8"
MAIN LEVEL
0'-0"
B.O. ROOF
±13'-9"
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
5" / 12"
5" / 12" 5" / 12"
5" / 1 2"
A7.2
SINGLE SLOPE RIDGE VENT
A7.2
EXISTING GUTTERS AND DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION (TYPICAL)
B.O. ROOF
±24'-10"
LOWER LEVEL
-10'-0"
B.O. ROOF
±35'-8"
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER SELF-
ADHERING ICE AND DAM PROTECTION MEMBRANE ON EXISTING
PLYWOOD ROOF SHEATHING - INSTALL SELF-ADHERING ICE
AND DAM MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER
SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
A7.1
10" / 12" 10" /
2"
INSTALL ICE AND DAM
PROTECTION MEMBRANE OVER
THIS ENTIRE ROOF PLANE
RIDGE VENT (TYPICAL)
A7.1
RIDGE VENT (TYPICAL)
EXISTING GUTTERS AND
DOWNSPOUTS TO REMAIN
PROTECT DURING
CONSTRUCTION (TYPICAL)
REMOVE AND REPLACE
PLYWOOD SHEATHING
APPROX. LOCATION SHOWN
PROVIDE ADDITIONAL
REINFORCING TO EXISTING
TRUSSES WHERE SHEATHING IS
REPLACED - AT THIS LOCATION
B.O. ROOF
±8'-8"
MAIN LEVEL
0'-0"
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER
SELF-ADHERING ICE AND DAM PROTECTION MEMBRANE
ON EXISTING PLYWOOD ROOF SHEATHING - INSTALL
SELF-ADHERING ICE AND DAM MEMBRANE ON
ENTIRETY OF 3:12 SLOPED ROOF
5" / 12"
SINGLE SLOPE RIDGE VENT
A7.2
A7.2
EXISTING GUTTERS AND DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION (TYPICAL)
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A3.3
EXTERIOR
ELEVATIONS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 1/8" = 1'-0"
AREA - C1 SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
AREA - C2 SOUTH WEST ELEVATION
SCALE: 1/8" = 1'-0"
AREA - C2 SOUTH EAST ELEVATION
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
±18'-4"
MAIN LEVEL
0'-0"
B.O. ROOF
±30'-1"
B.O. ROOF
±21'-8"
B.O. ROOF
±10'-7"
MAIN LEVEL
0'-0"
ALTERNATE NO. 1 - NEW SHINGLES OVER ROOFING
UNDERLAYMENT - INSTALL SELF-ADHERING ICE AND
DAM PROTECTIONMEMBRANE - EXTEND 2' MINIMUM
BEYOND INSIDE FACE OF WALL BELOW (TYPICAL)
ALTERNATE NO. 1 - NEW SHINGLES OVER
ROOFING UNDERLAYMENT - INSTALL
SELF-ADHERING ICE AND DAM
PROTECTIONMEMBRANE - EXTEND 2'
MINIMUM BEYOND INSIDE FACE OF WALL
BELOW (TYPICAL)
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER SELF-
ADHERING ICE AND DAM PROTECTION MEMBRANE ON EXISTING
PLYWOOD ROOF SHEATHING - INSTALL SELF-ADHERING ICE AND
DAM MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
10" /
2" 10" / 12"
10" /
2" 10" / 12"
10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" /
2" 10" / 12"
10" /
2" 10" / 12"
10" /
2" 10" / 12"
A7.1
A7.1
INSTALL ICE AND DAM
PROTECTION
MEMBRANE OVER THIS
ENTIRE ROOF PLANE
RIDGE VENT (TYPICAL)
A7.1
A7.1
_____RIDGE VENT (TYPICAL)
RIDGE VENT (TYPICAL)
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAILS 5/A7.2
(TYPICAL ON AREAS B1 AND B2)
ALTERNATE NO. 2 - NEW PREFINISHED
GUTTER TO MATCH EXISTING
GUTTERS TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
DOWNSPOUT TO MATCH EXISTING
DOWNSPOUT TO REMAIN (TYPICAL) - TIE
NEW DOWNSPOUT INTO EXISTING - MODIFY
AS REQUIRED TO MAKE CONNECTION
A7.2
0.25
0.25
0.2512
0.25
DOWNSPOUT SHALL
NOT BLOCK EXISTING
VENTS (TYPICAL)
REMOVE AND REPLACE PLYWOOD SHEATHING
APPROX. LOCATION SHOWN
PROVIDE ADDITIONAL REINFORCING TO EXISTING TRUSSES
WHERE SHEATHING IS REPLACED - AT THIS LOCATION
EXISTING GUTTERS AND DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION (TYPICAL)
B.O. ROOF
±11'-2"
MAIN LEVEL
0'-0"
5" / 1 2" 5" / 1
2"
5" / 12"
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER SELF-
ADHERING ICE AND DAM PROTECTION MEMBRANE ON EXISTING
PLYWOOD ROOF SHEATHING - INSTALL SELF-ADHERING ICE AND
DAM MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
A7.2
A7.2
SINGLE SLOPE RIDGE VENT
SINGLE SLOPE
RIDGE VENT
EXISTING GUTTERS AND DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION (TYPICAL)
B.O. ROOF
±10'-10"
MAIN LEVEL
0'-0"
B.O. ROOF
±13'-3"
10" /
2" 10" / 12"
10" / 12"10" /
2"
5" / 1 2"
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
A7.1
A7.2
RIDGE VENT (TYPICAL)
SINGLE SLOPE RIDGE VENT
NEW SHINGLES OVER ROOFING UNDERLAYMENT
OVER SELF-ADHERING ICE AND DAM PROTECTION
MEMBRANE ON EXISTING PLYWOOD ROOF
SHEATHING - INSTALL SELF-ADHERING ICE AND DAM
MEMBRANE ON ENTIRETY OF 2-1/2:12 SLOPED ROOF
EXISTING GUTTERS AND DOWNSPOUTS TO REMAIN -
PROTECT DURING CONSTRUCTION (TYPICAL)
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A3.4
EXTERIOR
ELEVATIONS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
SCALE: 1/8" = 1'-0"
AREA - C2 NORTH EAST ELEVATION
SCALE: 1/8" = 1'-0"
AREA - C2 NORTH WEST ELEVATIONS
SCALE: 1/8" = 1'-0"
AREA - B2 AND C2 NORTH ELEVATIONS
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
A7.1
A7.1
A7.1
B.O. ROOF
MAIN LEVEL
B.O. ROOF
B.O. ROOF
B.O. ROOF
10" /
2" 10" / 12"
10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" /
2" 10" / 12"
10" /
2" 10" / 12" 10" /
2" 10" / 12" 10" /
2" 10" / 12"
10" / 12" 10" /
2"
10" /
2" 10" / 12"
10" / 12"10" /
2" 10" / 12"10" /
2"
NEW SHINGLES OVER ROOFING UNDERLAYMENT OVER SELF-
ADHERING ICE AND DAM PROTECTION MEMBRANE ON EXISTING
PLYWOOD ROOF SHEATHING - INSTALL SELF-ADHERING ICE AND
DAM MEMBRANE ON ENTIRETY OF 3:12 SLOPED ROOF
A7.1
ALTERNATE NO. 2 - NEW
PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
DOWNSPOUT TO MATCH EXISTING
DOWNSPOUT TO REMAIN (TYPICAL) - TIE
NEW DOWNSPOUT INTO EXISTING - MODIFY
AS REQUIRED TO MAKE CONNECTION
ALTERNATE NO. 2 - NEW
PREFINISHED GUTTER TO
MATCH EXISTING GUTTERS
TO REMAIN (TYPICAL)
ALTERNATE NO. 2 - NEW PREFINISHED
DOWNSPOUT TO MATCH EXISTING
DOWNSPOUT TO REMAIN (TYPICAL) - TIE
NEW DOWNSPOUT INTO EXISTING - MODIFY
AS REQUIRED TO MAKE CONNECTION
A7.2
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAILS 5/A7.2
(TYPICAL ON AREAS B1 AND B2)
RIDGE VENT (TYPICAL)
ROOF WALL VENT UNDER DORMER
WINDOWS - DETAILS 5/A7.2
(TYPICAL ON AREAS B1 AND B2)
RIDGE VENT (TYPICAL)
0.25
0.25
0.25
0.25
0.25
0.25
DOWNSPOUT SHALL
NOT BLOCK EXISTING
VENTS (TYPICAL)
DOWNSPOUT SHALL
NOT BLOCK EXISTING
VENTS (TYPICAL)
0.25
0.25
SCALE: 1/8" = 1'-0"
AREA - B1 NORTH ELEVATION (ALTERNATE NO. 1 AND NO. 2)
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A3.5
EXTERIOR
ELEVATIONS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
EXISTING
100% CD SET
NORTH
PLAN
KEY PLAN
A
B2
C2
SCALE: NOT TO SCALE
A3.5
A3.4
A3.4
A3.4
A3.3
A3.3
A3.3
A3.2
A3.2
A3.1
A3.1
C1B1
NEW SHINGLES OVER
ROOF UNDERLAYMENT
SEAMLESS PREFINISHED METAL
GUTTER - REPLACE AT LOCATIONS
SHOWN ON PLANS AND
ELEVATIONS PER ALTERNATE NO.
2 - PROFILE TO MATCH EXISTING
3" X 4" PREFINISHED METAL
DOWNSPOUT - BEYOND - AT
LOCATIONS SHOWN ON
PLANS AND ELEVATIONS
PER ALTERNATE NO. 2
PREFINISHED METAL DRIP
EDGE - STYLE "D"
EXISTING PLYWOOD SHEATHING
- REMOVE AND REPLACE WHERE
DETERIORATED
EXTEND ICE AND DAM PROTECTION
MEMBRANE 2' MINIMUM BEYOND
INTERIOR FACE OF WALL
10" / 12"
EXISTING CONT.
SOFFIT VENT
EXISTING SOFFIT
RIDGE SHINGLE
EXISTING PLYWOOD SHEATHING
- REMOVE AND REPLACE WHERE
DETERIORATED
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING WOOD TRUSS
10" /
2" 10" / 12"
PRE-MANUFACTURED
RIDGE VENT
ASPHALT SHINGLES OVER ROOF
UNDERLAYMENT
EXISTING PLYWOOD SHEATHING
- REMOVE AND REPLACE WHERE
DETERIORATED
EXISTING WOOD TRUSS
MEMBRANE FLASHING COLLAR -
OVERLAP COLLAR ONTO LOWER
LAYER OF ROOF UNDERLAYMENT
UPPER LAYER OF ROOF
UNDERLAYMENT - CUT AROUND
PIPE PENETRATION AND LAP
OVER MEMBRANE COLLAR
METAL FLASHING COLLAR OVER
MEMBRANE FLASHING COLLAR -
OVERLAP COLLAR ONTO LOWER
LAYER OF ROOF SHINGLES
EXISTING THROUGH ROOF
PIPE PENETRATION
SEAL TOP OF FLASHING PERIMETER
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING LAP SIDING AND TRIM -
REMOVE, SALVAGE, AND REINSTALL
AS NEEDED TO ACCOMPLISH WORK
EXISTING SOFFIT
EXISTING PLYWOOD
SHEATHING - REMOVE AND
REPLACE WHERE
DETERIORATED
5" / 1 2"
METAL STEP FLASHING -
EXTEND VERTICALLY 5" MIN.
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
EXISTING LAP SIDING AND
TRIM - REMOVE, SALVAGE,
AND REINSTALL AS NEEDED
TO ACCOMPLISH WORK
LAP SIDING OVER NEW
FLASHING - MAINTAIN 2"
MINIMUM CLEARANCE
ABOVE ROOF
METAL STEP FLASHING -
EXTEND VERTICALLY 5" MIN.
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
LAP SIDING OVER NEW
FLASHING - MAINTAIN 2"
MINIMUM CLEARANCE
ABOVE ROOF
EXISTING LAP SIDING AND
TRIM - REMOVE, SALVAGE,
AND REINSTALL AS NEEDED
TO ACCOMPLISH WORK
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
EXISTING SOFFIT
EXTEND ICE AND DAM
PROTECTION MEMBRANE
2' MINIMUM BEYOND
INTERIOR FACE OF WALL
EXISTING CONT.
SOFFIT VENT
" 5
EXISTING GUTTER
TO REMAIN
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
EXISTING WOOD TRUSS
NEW SHINGLES OVER
ROOF UNDERLAYMENT
10" /
2"
FLASHING AT SLOPE
TRANSITION PER
MANUFACTURER'S
STANDARD DETAIL
METAL STEP FLASHING -
EXTEND VERTICALLY 5" MIN.
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
LAP SIDING OVER NEW
FLASHING - MAINTAIN 2"
MINIMUM CLEARANCE ABOVE
ROOF
EXISTING LAP SIDING AND
TRIM - REMOVE, SALVAGE,
AND REINSTALL AS NEEDED
TO ACCOMPLISH WORK
METAL STEP FLASHING
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
EXISTING LAP SIDING AND
TRIM - REMOVE, SALVAGE,
AND REINSTALL AS NEEDED
TO ACCOMPLISH WORK
LAP SIDING OVER NEW
FLASHING - MAINTAIN 2"
MINIMUM CLEARANCE
ABOVE ROOF
2"
ROOF WALL VENT
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A7.1
ROOF DETAILS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
SD
100% CD SET
SCALE: 1 1/2" = 1'-0"
GUTTER DETAIL
SCALE: 1 1/2" = 1'-0"
RIDGE DETAIL
SCALE: 1 1/2" = 1'-0"
ROOF PENETRATION DETAIL
SCALE: 1 1/2" = 1'-0"
ROOF EDGE DETAIL
SCALE: 1 1/2" = 1'-0"
ROOF TO SIDING CONNECTION
SCALE: 1 1/2" = 1'-0"
ROOF DETAIL AT OVERHANG
SCALE: 1 1/2" = 1'-0"
SLOPED TO LOW-SLOPED ROOF RIDGE
SCALE: 1 1/2" = 1'-0"
ROOF TO WALL CONNECTION
SCALE: 1 1/2" = 1'-0"
ROOF TO SIDING w/ VENT CONNECTION
EPDM MEMBRANE
EXISTING SHEATHING
EXTEND NEW EPDM MEMBRANE
UP VERTICAL FACE AND TIE INTO
EXISTING MEMBRANE ROOF
WITH COMPATIBLE FLASHING
LAP MEMBRANE FLASHING
EXISTING MASONRY VENEER
EXISTING REGLET COUNTER FLASHING
METAL STEP FLASHING
- EXTEND VERTICALLY 5" MIN.
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING ROOF HATCH
RUN EPDM MEMBRANE UP
EXISTING HATCH CURB
EPDM TO TOP OF WALL
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
SEALANT
TERMINATION STRIP
METAL "Z" FLASHING
KEEPER
2X TREATED
WOOD BLOCKING
PREFINISHED
METAL COPING CAP
NEW SHINGLES OVER
ROOF UNDERLAYMENT
1"
SINGLE SLOPE
RIDGE VENT
MIN.
6"
NEW EPDM ROOF
MEMBRANE
EXISTING STRUCTURE
REGLET AND
COUNTERFLASHING
PRE-MANUFACTURED
ROOF CURB
RUN EPDM MEMBRANE
UP ROOF CURB -
COORDINATE WITH
MECHANICAL
CONTINUOUS 1-1/2"
NEOPRENE CUSHION
AT PERIMETER
LAP SEALANT
NEW MECHANICAL
EQUIPMENT
LAP SEALANT
M
IN
M
IN
BLOCKING AS
REQUIRED BY ROOF
CURB MANUFACTURER
EXISTING EPDM
ROOF MEMBRANE
EXISTING INSULATION
1/2" FURRING CHANNEL
5/8" GYPSUM BOARD
TYPE "C"
RIGID INSULATION TO
MATCH ADJACENT SYSTEM
METAL ROOF DECK
NEW CONTINUOUS
SOFFIT VENT
EXISTING SOFFIT
TO REMAIN
EXISTING PLYWOOD SHEATHING -
REMOVE AND REPLACE WHERE
DETERIORATED
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXTEND ICE AND DAM PROTECTION
MEMBRANE 2' MINIMUM BEYOND
INTERIOR FACE OF WALL
EXISTING LAP
SIDING AND TRIM
5x5 PREFINISHED
METAL GUTTER
TONGUE AND GROOVE
WOOD SOFFIT TO
MATCH EXISTING
EXISTING FASCIA
PREFINISHED METAL
DOWNSPOUT
9" /
2"
METAL STEP FLASHING
NEW SHINGLES OVER
ROOF UNDERLAYMENT
EXISTING PLYWOOD
SHEATHING - REMOVE
AND REPLACE WHERE
DETERIORATED
ROOF WALL VENT
1"
EXISTING FIBER
CEMENT TRIM
SHINGLES OVER ROOF
VENT
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/2
/2
:5 :0
P
M A7.2
ROOF DETAILS
SD
SH
0241298.00
HONEY CREEK
RESORT - LODGE
ROOF REPLACEMENT
DAS PROJECT 9435.00
12633 RESORT DR,
MORAVIA, IA 52571
03/10/2025
SD
100% CD SET
SCALE: 1 1/2" = 1'-0"
ROOF EDGE
SCALE: 1 1/2" = 1'-0"
MID-ROOF DETAIL
SCALE: 1 1/2" = 1'-0"
ROOF AT CHIMNEY DETAIL
SCALE: 1 1/2" = 1'-0"
EXISTING ROOF HATCH
SCALE: 1 1/2" = 1'-0"
ROOF CURB INFILL AND NEW CURB DETAIL
SCALE: 1 1/2" = 1'-0"
ROOF DETAIL AT OVERHANG WITH SOFFIT VENT
SCALE: 1 1/2" = 1'-0"
ROOF AT WINDOW SILL DETAIL
ABOVE CEILING/AIR CONDITIONERAC
OUTDOOR AIROA
AIR COOLED CONDENSERACC
AIR FILTERAF
ABOVE FINISHED FLOORAFF
AIR HANDLING UNITAHU
AIR MEASURING STATIONAMS
AIR SEPARATORAS
AUTOMATIC AIR VENTAV
BOILERB
BUILDING AUTOMATION SYSTEMBAS
BACKDRAFT DAMPERBDD
BELOW FINISHED CEILINGBFC
BACKFLOW PREVENTION DEVICEBFP
BETWEEN JOISTSBJ
BOTTOM OF DUCTBOD
BOTTOM OF PIPEBOP
BRITISH THERMAL UNITS PER HOURBTUH
COMPRESSED AIRCA
COUNTER BALANCED SHUTTERCBS
COOLING COILCC
CEILING / CIRCULATING FANCF
CUBIC FEET PER MINUTECFM
CHILLERCH
CHILLED WATER PUMPCHP
CHILLED WATER RETURNCHR
CHILLED WATER SUPPLYCHS
CONVECTORCNV
CONDENSATECOND
CONDENSATE PUMPCP
CONDENSING UNITCU
CONTROL VALVECV
DOMESTIC COLD WATERCW
CONDENSER WATER PUMPCWP
CONDENSER WATER RETURNCWR
CONDENSER WATER SUPPLYCWS
DRY COOLERDC
DN DOWN
DP DIFFERENTIAL PRESSURE
DS DUCT SILENCER
EA EXHAUST AIR
EBB ELECTRIC BASEBOARD HEATER
EF EXHAUST FAN
EG EXHAUST GRILLE (LESS DAMPER)
EHC ELECTRIC HEATING COIL
EL ELEVATION
ER EXHAUST REGISTER
ERV ENERGY RECOVERY VENTILATOR
ET EXPANSION TANK
FA FRESH AIR
FD FIRE DAMPER
FDC FLEXIBLE DUCT CONNECTION
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
FPC FLEXIBLE PIPE CONNECTION
FPT FAN POWERED AIR TERMINAL
FT FINNED TUBE RADIATION
GF GAS FURNACE
GIH GRAVITY INTAKE HOOD
GPM GALLONS PER MINUTE
GR GLYCOL RETURN
GS GLYCOL SUPPLY
GUH GAS UNIT HEATER
HU HUMIDIFIER
HC HEATING COIL
HCWR DUAL TEMPERATURE RETURN
HCWS DUAL TEMPERATURE SUPPLY
HP HEAT PUMP
HPR HIGH PRESSURE STEAM RETURN
HPS HIGH PRESSURE STEAM SUPPLY
HRC HEAT RECOVERY COIL
HS HUMIDITY SENSOR
HWP HOT WATER PUMP
HWR HOT WATER RETURN
LOW PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM RETURN
KITCHEN HOOD - COMMERCIAL
HEAT EXCHANGER
HOT WATER SUPPLY
LPS
LPR
KH
HX
HWS
THOUSANDS OF BTU PER HOUR
MOTORIZED DAMPER
MAKEUP AIR UNIT
MIXED AIR
MBH
MD
MAU
MA
OBD OPPOSED BLADE DAMPER
P PUMP
PBD PARALLEL BLADE DAMPER
PRV PRESSURE RELIEF VALVE
PS PRESSURE SWITCH
PSI POUNDS PER SQUARE INCH
PTAC
RA RETURN AIR
RF RETURN AIR FAN
RG RETURN GRILLE (LESS DAMPER)
RH ROOF HOOD
RHC REHEAT COIL
RLFA RELIEF AIR
RPZ REDUCED PRESSURE BFP
RR RETURN REGISTER (WITH DAMPER)
RTU ROOFTOP AIR HANDLING UNIT
SA SUPPLY AIR
SAS SELF-ACTING SHUTTER
SD SUPPLY DIFFUSER/SMOKE DAMPER
SF SUPPLY FAN / SQUARE FOOT
SFD SMOKE/FIRE DAMPER
SG SUPPLY GRILLE
SR SUPPLY REGISTER
TCAC TEMP. CONTROL AIR COMPRESSOR
TCAD TEMP. CONTROL AIR DRYER
TDV TRIPLE DUTY VALVE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TOD TOP OF DUCT
TOP TOP OF PIPE
UC UNIT COOLER
UFD UNDERFLOOR DUCT
UH UNIT HEATER
UV UNIT VENTILATOR
VAV VARIABLE AIR VOLUME TERMINAL
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
AUTOMATIC AIR VENT
TEMPERATURE SENSOR/SWITCH
PRESSURE GAUGE
THERMOMETER
PIPE ANCHOR
PIPE GUIDES
MANUAL AIR VENT
FLOW SENSOR/SWITCH
PIPE EXPANSION JOINT
PIPE UNION
CONCENTRIC REDUCER
ECCENTRIC REDUCER
WYE STRAINER
WYE STRAINER W/DRAIN VALVE
DIRECTION OF FLOW
STEAM BUCKET TRAP
STEAM F&T TRAP
BACKFLOW PREVENTER
PIPE TURNING UP
PIPE TURNING DOWN
TEE OFF TOP
TEE OFF BOTTOM
PIPE TEE
PIPE CAP
PLAN 90 DEGREE ELBOW
PLAN 45 DEGREE ELBOW
MOTORIZED SHUTTER
NOT TO SCALE
MS
NTS
GENERAL
HYDRONIC VENTILATION
GENERAL NOTES
DEMOLITION
UFT UNDERFLOOR FAN TERMINAL
HRV HEAT RECOVERY VENTILATOR (SENSIBLE)
EUH ELECTRIC UNIT HEATER
ESP EXTERNAL STATIC PRESSURE
INTERNAL STATIC PRESSUREISP
TSP TOTAL STATIC PRESSURE
PUMP
PC PLUMBING CONTRACTOR
EC ELECTRICAL CONTRACTOR
GC GENERAL CONTRACTOR
FLEXIBLE PIPE CONNECTOR
FCU FAN COIL UNIT
ALUMINUMAL
VRP VERTICAL RADIANT PANEL
DOOR AIR CURTAINDAC
DH DEHUMIDIFIER
DOAS DEDICATED OUTDOOR AIR SYSTEM
DSU DUCTLESS SPLIT UNIT
DX DX COOLING COIL
ERP ELECTRIC RADIANT PANEL
GRH GAS RADIANT HEATER
LOUVERL
PDH POOL ROOM DEHUMIDIFIER
PACKAGED TERMINAL AIR CONDITIONER
RP RADIANT PANEL
S1 12x12
EXISTING
EQUIPMENT TYPE
EQUIPMENT MARK
SHEET #
DETAIL #
AIRFLOW IN CFM
THROAT SIZE
MECHANICAL EQUIPMENT TAG
AIR TERMINAL DESIGNATION
KEYNOTE
DETAIL OR SECTION MARK
POINT OF NEW CONNECTION
CAP EXISTING PIPE OR DUCT
BOLD TEXT INDICATES PROPOSED ITEM
ITALIC TEXT INDICATES EXISTING ITEM
NEW
PRESSURE/TEMPERATURE PLUG
AHU-1
GUARD LOCKABLE GUARD WHERE INDICATED
EQUIPMENT TO BE CONTROLLED
GUARD
TEMP
HUMID
CO
ELEMENT TO BE MONITORED
LOCKABLE GUARD WHERE INDICATED
HUMIDISTAT
THERMOSTAT
SENSOR
SUPPLY DIFFUSER/REGISTER
RETURN REGISTER/GRILLE
EXHAUST REGISTER/GRILLE
DIFFUSER AIRFLOW PATTERN IF
OTHER THAN 4-WAY BLOW
FLEXIBLE BRANCH RUNOUT TO SUPPLY
DIFFUSER, 36" MAX LENGTH
CEILING RETURN REGISTER WITH LINED
DUCT FOR SOUND ATTENUATION OPEN
TO CEILING PLENUM
FLEXIBLE DUCT CONNECTION TO
EQUIPMENT OR BETWEEN DUCTS
VOLUME DAMPER
MOTORIZED DAMPER
FIRE DAMPER
SMOKE DAMPER
COMBINATION FIRE/SMOKE DAMPER
SUPPLY AIR DUCT TOWARDS
SUPPLY AIR DUCT AWAY
RETURN/OUTDOOR AIR DUCT TOWARDS
RETURN/OUTDOOR AIR DUCT AWAY
TRANSFER AIR
A. INSTALL EQUIPMENT TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING
HEIGHTS ARE INDICATED
B. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING
SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESS OTHERWISE INDICATED
C. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OF REMOVAL, WITH MINIMUM INTERFERENCE TO
OTHER INSTALLATIONS
D. THE INSTALLING CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL MECHANICAL EQUIPMENT
PUT INTO OPERATION PRIOR TO THE INSTALLATION OF A WORKING CONTROL SYSTEM.
A. VERIFY EXACT SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION WORK
B. RELOCATE, REMOVE, AND ADJUST ALL MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO
ACCOMPLISH SCOPE OF NEW WORK
C. EXISTING MECHANICAL ITEMS ARE SHOWN IN SCHEMATIC FORM BASED UPON EXISTING
CONSTRUCTION DOCUMENTS AND/OR FIELD INVESTIGATION
D. FIXTURES AND EQUIPMENT INDICATED TO BE REUSED OR SALVAGED SHALL REMAIN THE
PROPERTY OF THE OWNER AND BE STORED IN A LOCATION AS DIRECTED BY OWNER'S
REPRESENTATIVE
E. IN LOCATIONS WHERE EXISTING CONSTRUCTION IS REMOVED AND NO ADDITIONAL CONSTRUCTION IS INDICATED, PATCH EXISTING CONSTRUCTION TO MATCH ADJACENT SURFACES AND FINISHES
MECHANICAL EQUIPMENT INSTALLATION
PRESSURE SENSOR/SWITCH
EXHAUST AIR DUCT TOWARDS
EXHAUST AIR DUCT AWAY
TJ THROUGH JOISTS
CO2
3-WAY CONTROL VALVE
ANGLE GATE VALVE
ANGLE GLOBE VALVE
BALANCING/SHUTOFF VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
CALIBRATED BALANCING VALVE
CONTROL VALVE
EXPANSION VALVE
GATE VALVE
GLOBE VALVE
QUICK OPEN VALVE
SAFETY RELIEF VALVE
SOLENOID VALVE
VACUUM RELIEF VALVE
GAS COCK
PLUG VALVE
PRESSURE REDUCING VALVE (WATER)
PRESSURE REGULATOR (GAS)
PIPE SLOPE ARROW
WALL SWITCH
H
S
T
CFM
F
P
T
FLAT OVAL DUCT12x8Φ
ROUND DUCT12"ø
RECTANGULAR DUCT12x8
AHU
METERM
MECHANICAL CONTRACTORMC
SYMBOLS LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS
ABBREVIATIONS
LINE STYLE INDICATES DEMOLISHED ITEM
DDC CONTROLS
DDC CONTROLS HAVE BEEN CONTRACTED WITH JCI (TODD MAGNANI - (515) 202-9448
todd.l.magnani@jci.com). THIS CONTRACTOR TO COORDINATE CONTROLS INSTALLATION WITH JCI AND ENSURE THE WORK HAS BEEN COMPLETED FOR THIS UNIT. CONTACT JCI PRIOR TO BID TO COORDINATE ANY CONTROLS REQUIRED BY THE RTU EQUIPMENT SUPPLIER TO PROVIDE AND WORK NEEDED TO
COORDINATE WITH JCI THROUGHOUT THE PROJECT.
ROUTE TO
NEAREST ROOF
DRAIN
TRAP MUST BE REMOVABLE
FOR ACCESS AND CLEANING
ADAPTER
UNIT DRAIN PAN
STREET ELL
HAND TIGHTENED
PLUGGED TEE
CLEANOUT
X = FAN OUTLET PRESSURE +1/2"X = FAN INLET PRESSURE / 2
H = FAN INLET PRESSURE +1" H = 1/2" MIN.
H
X
FAN OUTLET PRESSURE
(BLOW-THRU ONLY)
FOR DRAW THRU UNITS FOR BLOW THRU UNITS
www.f-w.com Engineers | Architects | Surveyors | Scientists
GROUP
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
14225 UNIVERSITY AVENUE, SUITE 110
WAUKEE, IOWA 50263
(515) 225-3469 / info@f-w.com
ISSUE:
# DATE: DESCRIPTION:
DESIGNED:
/7
/2
:5 :4
P
M M0.1
GEN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .