RFB938800-01 - Drawings.pdf
PDF 4 MB Posted
- Attached to
- DPS P08 Water Infiltration Mitigation
- Solicitation number
- RFB938800-01
- Issued by
- Carroll County, Mechanicsville City, Iowa
About this file
This document contains drawings and specifications for a roof demolition and replacement project for the Iowa Department of Public Defense (DPS) at a facility in Mason City, Iowa. The project involves removing the existing roof, including shingles, sheathing, flashing, and other related components, and installing a new roof system. The drawings provide detailed information on the demolition and new construction requirements, including keynotes, general notes, and details. The state and local contract opportunity associated with this project is for DPS P08 Water Infiltration Mitigation, which seeks a contractor to provide all labor, materials, tools, and equipment necessary for the roof work at the Camp Dodge facility in Iowa.
The document does not provide information on pricing terms, set asides, incumbents, funding requirements, or other financial details. It focuses solely on the technical requirements of the roof demolition and replacement project, as depicted in the drawings and specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1257983-event.pdf | ||
| RFB938800-01 - Bid Form.pdf | ||
| RFB938800-01 - Project Manual.pdf | ||
| RFB988800-01 - Addendum 01.pdf | ||
| DPS P08 Water Infiltration Mitigation Drawing Sheets.html | HTML file | |
| RFB938800-01 - Notice to Bidders.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salzwedel Snapshot
DEMO GENERAL NOTES
DEMO KEYNOTES
HIDDEN UPPER ROOF ABOVE
DEMOLISH EXISTING ROOF CRICKET
REMOVE BRICK AND PREP FOR NEW FINISH
REMOVE DEICING CABLE AS NEEDED TO REINSTALL LATER
DEMO AND REPLACE METAL FLASHING
REMOVE METAL PANEL AND PREP FOR NEW FINISH
REMOVE SHINGLES - REPLACE SHEATHING BELOW IF DAMAGED
REMOVE GYPSUM WALL BOARD. INSULATION TO BE INSPECTED FOR ANY
WATER DAMAGE. THESE MATERIALS WILL BE REPLACED AFTER REPAIRS
HAVE BEEN MADE.
REMOVE THREE COURSES OF BRICK TO INSTALL NEW THROUGH WALL
FLASHING. SALVAGE and CLEAN BRICK TO BE REINSTALLED
EXISTING CANOPY BELOW
REMOVE ELECTRICAL BOX AND SAVE FOR REINSTALLATION.
REMOVE VALLEY FLASHING AS NEEDED
DASHED LINES INDICATE DEMOLITION. NOT ALL ITEMS NOTED FOR
CLARITY.
EACH CONTRACTOR TO CAREFULLY EXAMINE EXISTING CONDITIONS
PRIOR TO TIME OF BID.
CONTRACTOR SHALL INFILL, OR PATCH AND REPAIR ANY OPENING IN
EXISTING WALLS AS REQUIRED TO MAINTAIN EXISTING OR NEW RATED
CONSTRUCTION.
PATCH AND REPAIR EXISTING SURFACES, INDICATED TO REMAIN,
DAMAGED DURING DEMOLITION. PREPARE FOR INSTALLATION OF NEW
FINISHES AS SPECIFIED.
PROTECT EXISTING FINISHES TO REMAIN.
FINISHES AND OTHER ITEMS INDICATED FOR DEMOLITION SHALL BE
ADEQUATELY REMOVED TO PROVIDE A SUITABLE SUBSTRATE FOR THE
INSTALLATION OF PROPOSED MATERIALS AND FINISHES.
MAINTAIN WEATHER TIGHT CONDITIONS ON ALL EXISTING SPACES
THROUGHOUT CONSTRUCTION.
PROTECT AND BRACE EXISTING STRUCTURE AS REQUIRED TO MAINTAIN
STRUCTURAL INTEGRITY DURING DEMOLITION AND CONSTRUCTION.
ELECTRICAL EQUIPMENT / FIXTURES SHOWN FOR
REFERENCE ONLY.
A
B
C
D
E
F
G
H
INDICATES SHINGLES AND SHEATHING TO BE REMOVED AND
REPLACED AS NEEDED TO ALLOW PROPER INSTALLATION OF
THE NEW MATERIALS.
DEMO LEGEND
INDICATES EXISTING AREA OF NO RENOVATION
REMOVE AND REPLACE PER DIRECTION OF THE KEYNOTE
I
REMOVE GYP CEILING AS NEEDED TO ACCESS AFFECTED
AREA
A2.00
C M
B A
A R
C H
IT
E
C T
S
G
R A
N D
A V
E
S P
E N
C E
R
IA
(P
.2
.3
PROGRESS PRINT
NOT FOR CONSTRUCTION
DATE:
CMBA ARCHITECTS
REVISIONS
SHEET
D A
T E
P R
O J E
C T
P
LO
T D
A T
E
F
IL
E P
A T
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/2
/2
:2 :1
P
M
H
P ro je c ts
\2 D
A S
D P
S P
O W a te r In fi lt ra ti o n M it ig a ti o n \1
M
O D
E L \1
R e v it \D
A S
D P
S P
W a te r In fi lt ra ti o n M it ig a ti o n R
V T
.2 .r v t
8/21/2024 1:22:11 PM
A2.00
M A
S O
N C
IT
Y
IO
W A
/2
/2
D P
S P
W
A T
E R
I N
F
IL
T R
A T
IO
N
M
IT
IG
A
T
IO
N
IO
W
A D
A S
R O
O F
D E
M O
P L
A N
S
NO. DESCRIPTION DATE
1/8" = 1'-0"
ROOF DEMOLITION PLAN
1/2" = 1'-0"
Detail 2
N
N
DEMO GENERAL NOTES
DEMO KEYNOTES
HIDDEN UPPER ROOF ABOVE
DEMOLISH EXISTING ROOF CRICKET
REMOVE BRICK AND PREP FOR NEW FINISH
REMOVE DEICING CABLE AS NEEDED TO REINSTALL LATER
DEMO AND REPLACE METAL FLASHING
REMOVE METAL PANEL AND PREP FOR NEW FINISH
REMOVE SHINGLES - REPLACE SHEATHING BELOW IF DAMAGED
REMOVE GYPSUM WALL BOARD. INSULATION TO BE INSPECTED FOR ANY
WATER DAMAGE. THESE MATERIALS WILL BE REPLACED AFTER REPAIRS
HAVE BEEN MADE.
REMOVE THREE COURSES OF BRICK TO INSTALL NEW THROUGH WALL
FLASHING. SALVAGE and CLEAN BRICK TO BE REINSTALLED
EXISTING CANOPY BELOW
REMOVE ELECTRICAL BOX AND SAVE FOR REINSTALLATION.
REMOVE VALLEY FLASHING AS NEEDED
DASHED LINES INDICATE DEMOLITION. NOT ALL ITEMS NOTED FOR
CLARITY.
EACH CONTRACTOR TO CAREFULLY EXAMINE EXISTING CONDITIONS
PRIOR TO TIME OF BID.
CONTRACTOR SHALL INFILL, OR PATCH AND REPAIR ANY OPENING IN
EXISTING WALLS AS REQUIRED TO MAINTAIN EXISTING OR NEW RATED
CONSTRUCTION.
PATCH AND REPAIR EXISTING SURFACES, INDICATED TO REMAIN,
DAMAGED DURING DEMOLITION. PREPARE FOR INSTALLATION OF NEW
FINISHES AS SPECIFIED.
PROTECT EXISTING FINISHES TO REMAIN.
FINISHES AND OTHER ITEMS INDICATED FOR DEMOLITION SHALL BE
ADEQUATELY REMOVED TO PROVIDE A SUITABLE SUBSTRATE FOR THE
INSTALLATION OF PROPOSED MATERIALS AND FINISHES.
MAINTAIN WEATHER TIGHT CONDITIONS ON ALL EXISTING SPACES
THROUGHOUT CONSTRUCTION.
PROTECT AND BRACE EXISTING STRUCTURE AS REQUIRED TO MAINTAIN
STRUCTURAL INTEGRITY DURING DEMOLITION AND CONSTRUCTION.
ELECTRICAL EQUIPMENT / FIXTURES SHOWN FOR
REFERENCE ONLY.
A
B
C
D
E
F
G
H
INDICATES SHINGLES AND SHEATHING TO BE REMOVED AND
REPLACED AS NEEDED TO ALLOW PROPER INSTALLATION OF
THE NEW MATERIALS.
DEMO LEGEND
INDICATES EXISTING AREA OF NO RENOVATION
REMOVE AND REPLACE PER DIRECTION OF THE KEYNOTE
I
REMOVE GYP CEILING AS NEEDED TO ACCESS AFFECTED
AREA
Mechanical
A2.01
9 200
A2.01
Sim
A2.01
Sim
A2.01
Sim
A2.01
Sim
A2.01
Sim 2
A2.01
Sim
A2.01
Sim
A2.01
Sim
A2.01
Sim
N
VIF.
9"
VIF.
4 1/2"
4' - 0"
A2.01
A2.01
1' - 10"
3'
STIFFENER
DOOR AS
SCHEDULED
BLOCKING
AS REQUIRED
STIFFENER
DOOR AS
SCHEDULED
STIFFENER FLUSH BOLT LOCK
BLOCKING
AS REQUIRED
BLOCKING
AS REQUIRED
INSIDE RELEASE
GENERAL NOTES
KEYNOTES
BATT INSULATION
5/8" GYP PAINT WALL TO MATCH EXISTING
GROUT AIR SPACE SOLID BELOW FLASHING
THROUGH WALL FLASHING
WEATHER BARRIER
REINSTALL REMOVED BRICK
REINSTALL GYP AND INSULATION
PATCH BACK CEILING AS NEEDED - MATCH EXISTING THICKNESS AND
TEXTURE. PAINT TO MATCH EXISTING.
DRAFT STOP DOOR
BAFFLE LOCATED AT EACH EXISTING SOFFIT VENT
SELF-ADHERED FLASHING
ALL INTERIOR WALL ASSEMBLIES TO EXTEND TO DECK UNLESS NOTED
OTHERWISE.
CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING THE
AFFECTED WORK.
DO NOT SCALE DRAWINGS, FOLLOW DIMENSIONS.
PATCH AND REPAIR EXISTING WALLS, FLOORS, CEILINGS, ETC., THAT
ARE SHOWN TO REMAIN BUT ARE DAMAGED DUE TO CONSTRUCTION
WORK.
REMOVE CEILING AS NEEDED TO ACCESS AREAS HIGHLIGHTED IN
DRAWINGS
OWNER WILL REMOVE ALL WALL HUNG ITEMS
A
B
C
D
INDICATES EXISTING MATERIAL/CONSTRUCTION TO REMAIN
LEGEND
E
F
C M
B A
A R
C H
IT
E
C T
S
G
R A
N D
A V
E
S P
E N
C E
R
IA
(P
.2
.3
PROGRESS PRINT
NOT FOR CONSTRUCTION
DATE:
CMBA ARCHITECTS
REVISIONS
SHEET
D A
T E
P R
O J E
C T
P
LO
T D
A T
E
F
IL
E P
A T
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/2
/2
:2 :1
P
M
H
P ro je c ts
\2 D
A S
D P
S P
O W a te r In fi lt ra ti o n M it ig a ti o n \1
M
O D
E L \1
R e v it \D
A S
D P
S P
W a te r In fi lt ra ti o n M it ig a ti o n R
V T
.2 .r v t
8/21/2024 1:22:11 PM
A2.01
M A
S O
N C
IT
Y
IO
W A
/2
/2
D P
S P
W
A T
E R
I N
F
IL
T R
A T
IO
N
M
IT
IG
A
T
IO
N
IO
W
A D
A S
D E
M O
F L
O O
R P
L A
N
A T
T
IC
P L
A N
NO. DESCRIPTION DATE
1/8" = 1'-0"
FLOOR 01 - DEMO
1/8" = 1'-0"
ATTIC PLAN
1 1/2" = 1'-0"
BAFFLE DETAIL
DOOR SCHEDULE
DOOR NO.
DOOR
DOOR NO.
SIZE
TYPE (LIVE)WIDTH HEIGHT THICKNESS
201 1' - 8" 2' - 11" 1 3/4" F 201
200 1' - 8" 2' - 11" 1 3/4" F 200
FRAME 1
1 1/2" = 1'-0"
DOOR HEAD DOOR JAMB
GENERAL NOTES
KEYNOTES
METAL PANEL
ASPHALT SHINGLES - COLOR TO MATCH EXISTING
WOOD FRAMING AS REQUIRED
WATERPROOF MEMBRANE
5/8" PLYWOOD
METAL ROOF FLASHING
METAL PANEL DRIP CAP
REPLACE SHEATHING AS NEEDED IF DAMAGED
ROOF EDGE TRIM
PRE-FINISHED METAL FASCIA
PRE-FINISHED METAL SOFFIT - SOLID
CANOPY BELOW
PREFINISHED METAL FLASHING
REINSTALL DEICING CABLE
PRE-FINISHED METAL SOFFIT - VENTED
ROOF VALLEY FLASHING
RE-INSTALL ELECTRICAL BOXES
PONDING WATER WILL NOT BE ACCEPTED.
ROOF COPING (CAPS), FLASHING AND TRIMS SHALL BE SLOPED A
MINIMUM OF 1/2" PER 1'-0" UNLESS NOTED OTHERWISE
ROOF LAYOUT CRICKETS DIAGRAMMATIC IN NATURE FIELD VERIFY
PROPER SLOPES AND SIZE REQUIERMENTS
RE-USE SCUPPER AND OR GUTTER AND DOWNSPOUTS COORDINATE
WITH ARCHITECT
ICE AND WATER SHIELD TO EXTEND UP ROOF 3'-0" MIN. FROM OUTSIDE
FACE OF STUD WALL AND UP THE VERTICAL SURFACE OF THE WALL
ELECTRICAL EQUIPMENT / FIXTURES SHOWN FOR
REFERENCE ONLY.
A
B
C
D
E
RC ROOF CRICKET
INDICATES EXISTING MATERIAL/CONSTRUCTION TO REMAIN
LEGEND
F
A2.02
A2.01
N
A2.02
A2.02
A2.02
A2.02
Sim
/2
5 1/2" / 1'-0"
/2
A2.02
A2.02
Sim
/2
VIF.
7'-3 1/4"
V
IF
7' -6
/8
VIF.
6'-7 3/8"
V
IF
5' -2
/8
VIF.
2'-3 3/8"
V
IF
2'
-1
5/ 8"
V
IF
2' -0
/8
TRUSS BEARING
109' - 0 5/8"
V
IF
1' -1
1/
4"
V
IF
1' -9
V
IF
1' -5
/4
VIF.
1' - 2"
C M
B A
A R
C H
IT
E
C T
S
G
R A
N D
A V
E
S P
E N
C E
R
IA
(P
.2
.3
PROGRESS PRINT
NOT FOR CONSTRUCTION
DATE:
CMBA ARCHITECTS
REVISIONS
SHEET
D A
T E
P R
O J E
C T
P
LO
T D
A T
E
F
IL
E P
A T
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/2
/2
:2 :1
P
M
H
P ro je c ts
\2 D
A S
D P
S P
O W a te r In fi lt ra ti o n M it ig a ti o n \1
M
O D
E L \1
R e v it \D
A S
D P
S P
W a te r In fi lt ra ti o n M it ig a ti o n R
V T
.2 .r v t
8/21/2024 1:22:13 PM
A2.02
M A
S O
N C
IT
Y
IO
W A
/2
/2
D P
S P
W
A T
E R
I N
F
IL
T R
A T
IO
N
M
IT
IG
A
T
IO
N
IO
W
A D
A S
R O
O F
P L
A N
NO. DESCRIPTION DATE
1/8" = 1'-0"
Roof Plan
1/2" = 1'-0"
ROOF PLAN
1" = 1'-0"
Detail 1
1" = 1'-0"
DETAIL 2
1" = 1'-0"
Detail 3
1" = 1'-0"
DETAIL 4
GENERAL NOTES
KEYNOTES
BATT INSULATION
5/8" GYP PAINT WALL TO MATCH EXISTING
GROUT AIR SPACE SOLID BELOW FLASHING
THROUGH WALL FLASHING
WEATHER BARRIER
REINSTALL REMOVED BRICK
REINSTALL GYP AND INSULATION
PATCH BACK CEILING AS NEEDED - MATCH EXISTING THICKNESS AND
TEXTURE. PAINT TO MATCH EXISTING.
DRAFT STOP DOOR
BAFFLE LOCATED AT EACH EXISTING SOFFIT VENT
SELF-ADHERED FLASHING
ALL INTERIOR WALL ASSEMBLIES TO EXTEND TO DECK UNLESS NOTED
OTHERWISE.
CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING THE
AFFECTED WORK.
DO NOT SCALE DRAWINGS, FOLLOW DIMENSIONS.
PATCH AND REPAIR EXISTING WALLS, FLOORS, CEILINGS, ETC., THAT
ARE SHOWN TO REMAIN BUT ARE DAMAGED DUE TO CONSTRUCTION
WORK.
REMOVE CEILING AS NEEDED TO ACCESS AREAS HIGHLIGHTED IN
DRAWINGS
OWNER WILL REMOVE ALL WALL HUNG ITEMS
A
B
C
D
INDICATES EXISTING MATERIAL/CONSTRUCTION TO REMAIN
LEGEND
E
F
A2.03
A2.03
A2.03
Sim7
A2.03
Sim
V
IF
'-6
/4
V
IF
'-4
V
IF
1'
-0
VIF.
6'-3"
Floor 01 100' - 0"
TRUSS BEARING
109' - 0 5/8"
A2.03
9" 4 1/2"
V
IF
9' -0
/8
Floor 01 100' - 0"
TRUSS BEARING
109' - 0 5/8"
BOTT. OF TRUSS
113' - 0 5/8"
A2.02
Sim
V
IF
9' -0
/8
Floor 01 100' - 0"
1/8" = 1'-0"
Floor Plan
C M
B A
A R
C H
IT
E
C T
S
G
R A
N D
A V
E
S P
E N
C E
R
IA
(P
.2
.3
PROGRESS PRINT
NOT FOR CONSTRUCTION
DATE:
CMBA ARCHITECTS
REVISIONS
SHEET
D A
T E
P R
O J E
C T
P
LO
T D
A T
E
F
IL
E P
A T
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/2
/2
:2 :1
P
M
H
P ro je c ts
\2 D
A S
D P
S P
O W a te r In fi lt ra ti o n M it ig a ti o n \1
M
O D
E L \1
R e v it \D
A S
D P
S P
W a te r In fi lt ra ti o n M it ig a ti o n R
V T
.2 .r v t
8/21/2024 1:22:13 PM
A2.03
M A
S O
N C
IT
Y
IO
W A
/2
/2
D P
S P
W
A T
E R
I N
F
IL
T R
A T
IO
N
M
IT
IG
A
T
IO
N
IO
W
A D
A S
F L
O O
R P
L A
N S
NO. DESCRIPTION DATE
3/4" = 1'-0"
Section 1 3/4" = 1'-0"
Section 2
3" = 1'-0"
Brick Detail
| Sheets |
| A2.00 - ROOF DEMO PLANS |
| A2.01 - DEMO FLOOR PLAN & ATTIC PLAN |
| A2.02 - ROOF PLAN |
| A2.03 - FLOOR PLANS |
File details come from the government source that posted it. Updated .