RFB938700-02 MPCF IPI Stormwater_Drawings.pdf
PDF 3 MB Posted
- Attached to
- DOC MPCF IPI Building Stormwater Management
- Solicitation number
- RFB 938700-02
- Issued by
- Warren County, Iowa
About this file
This document is a set of drawings and specifications for the DOC MPCF IPI Building Stormwater Management project in Mount Pleasant, Iowa. The Iowa Department of Administrative Services is seeking bids for this project, which involves installing stormwater drainage infrastructure around the MPCF IPI building, including 145 linear feet of 8-inch PVC storm sewer piping, a metal pipe apron, slotted PVC subdrain, solid PVC roof drain collector, cleanouts, and other appurtenances. The contractor will also be responsible for removing and reinstalling 168 linear feet of 12-foot tall inner security fence, as well as providing construction surveying, concrete washout, and other incidental items. Bids are due on July 26, 2024, with a revised bid date of September 6, 2024. The contract will be awarded on a lump sum basis, with no specific quantities provided.
The project estimates are provided for reference only, as the contractor will be responsible for verifying all quantities. Pricing will be lump sum, with no specific set-asides or funding sources identified. There is no incumbent contractor mentioned, and the current environment indicates the need to install stormwater infrastructure to manage drainage around the existing MPCF IPI building.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-001
C O
VE
R
S H
EE
T
NN
DOC MPCF IPI BUILDING
STORMWATER MANAGEMENT
MOUNT PLEASANT, IOWA
DAS PROJECT NO. 9387.01
LEGEND
DRAWING INDEX
GENERAL NOTES
ABBREVIATIONS LOCATION MAP
I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.
Signature Date Bradley W. Roeth License Number 16536
My license renewal date is December 31, 2024
Sheets covered by this seal: ALL DRAWINGS
W PROPOSED WATER MAIN
Gx NATURAL GAS
Wx EXISTING WATER MAIN
PROPERTY LINE
EXISTING SANITARY SEWER
VALVE
HYDRANT
CURB STOP AND BOX
INV INVERT
LF LINEAR FEET
S SOUTH
SAN SANITARY
TYP TYPICAL
AVE AVENUE
ST STREET
MH MANHOLE
DI DUCTILE IRON
STA STATION
PERIMETER EROSION BARRIER
APPROX APPROXIMATE
MIN MINIMUM
MAX MAXIMUM
DR DRIVE
REDUCER
N NORTH
PH PHASE
STORM SEWER
SSx
SD
SANITARY MANHOLE
UTILITY POLE
EXST EXISTING
CONTROL POINTS
PROPERTY CORNER
OVERHEAD ELECTRICOE
ACCESS ENERGY COOPERATIVE
COMPANY NAME : ACCESS ENERGY COOPERATIVE
CONTACT NAME: Dan Philips
PHONE: 3193851577
EMAIL: dphilips@accessenergycoop.com
ALLIANT ENERGY
CONTACT NAME: Alliant Energy Field Engineer
PHONE: 8002554268
EMAIL: locate_IPL@alliantenergy.com
MEDIACOM BROADBAND, L.L.C.
CONTACT NAME: Mitch Hancock
PHONE: 3097434735
EMAIL: mhancock@mediacomcc.com
MOUNT PLEASANT MUNICIPAL UTIL
COMPANY NAME : MOUNT PLEASANT MUNICIPAL
CONTACT NAME: Jack Hedgecock
PHONE: 3193852121
EMAIL: mpugroup@mtputilities.com
MOUNT PLEASANT, CITY OF
COMPANY NAME : MOUNT PLEASANT, CITY OF
CONTACT NAME: Rick Mullin
PHONE: 3193851480
EMAIL: rmullin@iowatelecom.net
IOWA ONE CALL
UTILITY CONTACTS
PROJECT LOCATION
FO x EXISTING FIBER OPTIC
AREA LIGHT
STREET LIGHT
TREE
BURIED ELECTRICESx
SANITARY SEWERSS
EXISTING STORM SEWERSD x
STORM MANHOLE
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
W
A
BW
R
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R1. SPECIFICATIONS ARE BASED ON SUDAS 2024.
2. ALL BURIED UTILITY LOCATIONS ARE APPROXIMATE AND SHALL BE FIELD LOCATED PRIOR TO EXCAVATION.
3. CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES, DRIVES, STREETS AND OTHER ITEMS TO REMAIN, INCLUDING ANY NOT
SPECIFICALLY SHOWN IN THE DRAWINGS. DAMAGE TO EXISTING UTILITIES, DRIVES, STREETS AND OTHER ITEMS SHALL BE REPAIRED BY
THE CONTRACTOR AT HIS EXPENSE.
4. CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY CONFLICTS BETWEEN THE DRAWINGS AND EXISTING FEATURES.
5. CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF UNEXPECTED SUB-SURFACE CONDITIONS. DISCONTINUE WORK IN AREA
UNTIL NOTIFIED BY OWNER TO RESUME WORK.
6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING CONSTRUCTION LAYOUT FOR ALL GRADES AND FEATURES.
HAWKEYE DR
FOREST VIEW DR
W
IL
D T
U R
KE
Y
D R
NATURE VIEW DR
H
AW
KE
YE
D R
LIGHTNING LN
BELL DR
DEERPATH CIRCLE
HAWKEYE DR
SHEET NUMBER TITLE
REVISION
NUMBER
G-001 COVER SHEET 1
G-002 QUANTITIES AND ESTIMATE REFERENCE NOTES 1
C-010 OVERVIEW MAP, SHEET INDEX 1
C-090 REMOVALS 1
C-101 PLAN AND PROFILE 1
C-301 SECTIONS AND DETAILS 1
C-501 DETAILS 1
9/6/2024
G-002
Q U
AN
TI
TI
ES
AN
D
E
ST
IM
AT
E R
EF
ER
EN
C
E N
O
TE
S
PROJECT QUANTITIES AND ESTIMATE REFERENCE NOTES
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
FOR USE AS REFERENCE ONLY. THESE QUANTITIES ARE ESTIMATES ONLY. PROJECT TO BE BID AS LUMP SUM. ITEMS REQUIRED BY SPECIFICATIONS OR DRAWINGS BUT NOT LISTED ARE CONSIDERED INCIDENTAL TO ITEMS LISTED. CONTRACTOR TO VERIFY QUANTITIES.
BID ITEM
SUDAS ITEM
CODE TITLE UNIT
ESTIMATED
QTY ESTIMATE REFERENCE NOTES
1 2010-I SUBGRADE TREATMENT, PLASTIC SHEETING SY 62 Furnishing, placing, and incorporating 10-mil plastic sheeting as an infiltration barrier below rock surfacing. Removal and replacement of rock surfacing will be performed by MPCF staff.
2 4020-A2 STORM SEWER, TRENCHLESS, PVC, 8" LF 145 Furnishing and installing solid wall PVC pipe; trenchless installation materials and equipment; pit excavation; dewatering; placing and compacting backfill material; pipe connections; testing; and inspection.
3 4030-B PIPE APRON, METAL, 8" EA 1 Trench excavation; dewatering; furnishing and installing the apron;
furnishing, placing, and compacting bedding and backfill material; shaping outlet channel to existing grades; connectors; and other appurtenances.
4 4040-A SUBDRAIN, SLOTTED PVC, 8" LF 140 Trench excavation, disposal of unsuitable trench material, furnishing and placing bedding and backfill material, engineering fabric, connectors, and elbows and tees. Includes regrading surface to slope away from the building and preparation of surface for plastic sheeting.
5 4040-B ROOF DRAIN COLLECTOR, SOLID PVC, 8" LF 140 Trench excavation, disposal of unsuitable trench material, furnishing and placing solid wall PVC, engineering fabric, pipe, wyes, tap, fittings, and bedding and backfill material. Includes regrading surface to slope away from the building and preparation of surface for plastic sheeting.
6 4040-C TYPE B CLEANOUT, 36'' EA 2 Trench excavation, disposal of unsuitable trench material, furnishing and installing cleanout and casting; and furnishing, placing, and compacting bedding and backfill material.
7 4040-C TYPE A-2 CLEANOUT, 8'' EA 2 Trench excavation, disposal of unsuitable trench material, furnishing cleanout and lid; and furnishing, placing, and compacting bedding and backfill material.
8 4040-E ROOF DRAIN SERVICE STUB, PVC, 2" SUMP OUTLET LF 6 Trench excavation, furnishing bedding material, placing bedding and backfill material, PVC pipe and fittings.
9 4040-E ROOF DRAIN SERVICE STUB, PVC, 6" DOWNSPOUT LF 40 Trench excavation, furnishing bedding material, placing bedding and backfill material, PVC pipe and fittings.
10 9010-A CONVENTIONAL SEEDING, TYPE 1 SY 100 Removal of rock and other debris from the area; repairing rills and washes;
preparing the seedbed; furnishing and placing seed, including any treatment required; furnishing, applying, and incorporating fertilizer to the area to be seeded; furnishing, applying, and incorporating mulch to the area to be seeded. MPCF staff will furnish water and other care during the care period.
11 9040-F-1 SWPPP MEASURES - WATTLES, 9" LF 100 Includes installation, maintenance, and removal.
12 9060-D REMOVAL AND REINSTALLATION OF EXISTING
FENCE AND GATE INCLUDING CONCRETE POST
FOUNDATIONS
LF 168 Work is related to the 12ft high inner security fence along north side of building to widen the area available for construction operations. Includes disassembly and reassembly of existing fence, personnel gate, chainlink mesh, rails, supports, hardware and ties; new 4" galvanized steel posts;
excavation, new concrete post foundations (2'-0" diameter x 4ft depth);
new grounding rod at midpoint of reassembled fence. Electrical conduits may be removed and not replaced. MPCF staff will remove and reinstall the 4 layers of razor wire that are attached to the fence.
13 9060-D SECURE FENCING AT END OF EACH WORK DAY LS 1 Full height closure of any fence openings required for construction at end of each work day. Anticipated location is 10ft between northeast building corner and exterior fence.
14 11010-A CONSTRUCTION SURVEY LS 1 Autocad design files will be provided to contractor. Staking locations and elevations are the responsibility of the contractor.
15 11020-A MOBILIZATION LS 1 The movement of personnel, equipment, and supplies to the project site;
the establishment of offices, buildings, and other facilities necessary for the project; and bonding, permits, and other expenses incurred prior to construction.
16 11050-A CONCRETE WASHOUT LS 1 Providing concrete washwater containment, collection, and disposal.
HAWKEYE CIRCLE
N
AT
U R
E
VI
EW
D
R
W
IL
D T
U R
KE
Y
D R
TANAG
ER LN
NATURE VIEW DR
FOREST VIEW DR
TANAGER LN
HAWKEYE CIRCLE
H
AW
KE
YE
C
IR
C
LE
X X X XXX
X X
X X
X X X X
X
G x G x
G x G x
G x G x
G x
G x
G x
G x
X X
X
WxWx
Wx Wx Wx Wx
W x
W x
W x
W x
W x
W x
W x
W x
SS x
SS
x
ES
x
SD x
C x
C x
ES x
ES
x
ES x
ES
x
ES x
ES
x
ES x
ES
x
ES x
ES
x
X X
X X
XXXXX
X X X X X
SDSD
SD
NN
O
VE
R
VI
EW
M
AP
C-010
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
C-101
CONTROL POINTS
POINT N (FT) E (FT) ELEV. (FT) DESCRIPTION
CP01 353,844.70 2,183,547.08 708.97 WOOD STAKE WITH TACK
CP02 353,843.71 2,183,511.02 710.43 WOOD STAKE WITH TACK
CP03 353,721.04 2,183,486.19 708.97 "X" MARK ON CONCRETE
CP02 CP01
CP03
100'0 50'
N
AT
U R
E
VI
EW
D
R
X X X X X X X X X X X X X X X X X X
X
X X
XXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X
X
X
X
X
G x
G x
G x
G x
G x
G x
G x
Wx Wx Wx Wx
Wx Wx Wx Wx
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
SS x
SS x
SS x
SS x
SS x
SS x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SD x SD x
ESx
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
SD x SD x
SD x SD x
SD x SD x
SD x SD x
SD
x
SD
x
SD
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
C x C x
C x
C x
C x
C x
C x
C x
C x
C x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
X X
X X X X
X X
X X
X X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXX
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
SF
SF
SF
R
EM
O
VA
LS
C-090
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
NN
0 20'10'
8" WATER MAIN
4" STEEL GAS
EDGE OF
PAVEMENT
CONCRETE FENCE FOUNDATION,
ESTIMATED DEPTH 48" BELOW
GRADE, 24" THICK
OUTER SECURITY FENCE
WITH CONTINUOUS
CONCRETE FOOTING 48"
BELOW GRADE (TYP)
SANITARY SEWER
CONTRACTOR TO REMOVE AND
REPLACE SECURITY FENCE
AND GATE 12' TALL, 10 LF.
REMOVE AND REPAIR
CONCRETE
FOUNDATION WALL
AS NEEDED TO
INSTALL 8" PIPE
REMOVE 4" CLEANOUT. PLUG ABANDONED DRAIN WITH CONCRETE
MPCF STAFF WILL REMOVE,
STOCKPILE AND REPLACE CLEAN
ROCK SURFACING, 143 SY
THIS AREA IS AVAILABLE FOR STOCKPILING
ROCK AND MATERIAL STORAGE
SECURITY FENCE
SECURITY FENCE
4" FOOTING DRAIN OUTLET
158'- 0"
REMOVE AND RECONSTRUCT INNER SECURITY FENCE, CHAIN-LINK
MESH, POLES AND CONCRETE, 12 FT HIGH X 158 LF AND 16 EA 2'
DIA X 5' DEEP POST FOUNDATIONS. RAZOR WIRE WILL BE
REMOVED AND REINSTALLED BY MPCF STAFF.
IPI BUILDING
INNER SECURITY FENCE
WITH CONCRETE
FOUNDATIONS AT EACH
POLE (TYP)
CONTRACTOR TO SECURE
FULL HEIGHT CLOSURE AT
THE END OF EACH WORK DAY
X X X X X X X X X X X X X X
X
X X
XXXXXXXXXXXXX
X X
X X
X X
X
X X
X X
X X
X
X
X X
X
X X X
X
X
X
X
X
X
X
X
G x
G x
G x
G x
G x
G x
G x
W x
W x
W x
W x
W x
W x
W x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
ESx
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
SD x SD x
SD x SD x
SD x SD x
SD x SD x
SD
x
SD
x
SD
x
ES
x
ES
x
ES
x
ES
x
ES
x
ES
x
C x C x
C x
C x
C x
C x
C x
C x
C x
C x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
ES x ESx
ES x ES x
ES x ES x
ES x
ES x
ES
x
ES
x
SD SD SD SD SD SD SD SD
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
SF
SF
SF
SF
SF
SF
EL
EV
AT
IO
N
STATION
0+00 1+00 2+00
PL
AN
P
R O
FI
LE
C-101
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
NN
EXISTING SURFACE
8" SLOTTED PVC
8" SOLID WALL PVC
145'- 0"
0 20'10'
8" WATER MAIN (UNVERIFIED LOCATION)
TOP OF FLOOR EL 717.50'
CONCRETE FENCE FOUNDATION
CONCRETE FENCE FOUNDATION (AT POSTS ONLY)
8" X 6" TEE
8" X 6" TEE
8" 90° ELBOW
CLEAN OUT ASSEMBLY
8" STORM DRAIN
34 LF @ 1.00%
8" STORM DRAIN
143 LF @ 3.20%
4" STEEL GAS MAIN
EDGE OF
PAVEMENT
CONCRETE FENCE FOUNDATION
SECURITY FENCE
8" X 6" TEE
6" LATERAL FOR DOWNSPOUT
8" X 6" TEE
6" LATERAL FOR DOWNSPOUT
SANITARY SEWER
(FROM MAPPING)
BORE PIT
BORE PIT
CONNECT EXISTING 4" PVC FOOTING
DRAIN TO TYPE B CLEANOUT
ASSUMED ELECTRICAL
CONDUIT LOCATON
8" CLEANOUTS
ELECTRICAL CONDUITS
ELECTRICAL CONDUITS
EXISTING GATE
COMMUNICATION CONDUIT
COMMUNICATION
CONDUIT
8" X 6" TEE FOR SUMP PUMP
DISCHARGE CONNECTION
8" X 6" TEE
CONNECT 2" PVC SUMP PUMP
DISCHARGE TO 6" LATERAL
TYPE B SUBDRAIN CLEAN OUT
TUNNEL
TYPE B SUBDRAIN CLEAN OUT
RIM EL 718.00
8' X 8' TUNNEL WITH EXISTING SUMP PUMP AND 2" DISCHARGE PIPE
8" SANITARY SEWER (ASSUMED DEPTH AND LOCATION)
INVERT EL 713.77
8" WATER MAIN (ASSUMED DEPTH AND LOCATION)
4" STEEL GAS MAIN
(POTHOLED LOCATION)
BURIED ELECTRICAL
BURIED ELECTRICAL (ASSUMED
DEPTH AND LOCATION)
8" STORM DRAIN 5 LF @ 1.00%
8" STORM DRAIN
43 LF @ 1.00%
8" STORM DRAIN
38 LF @ 1.00%
8" METAL PIPE APRON
INSERT REMOVABLE FORK
TYPE RODENT GUARD
8" METAL PIPE APRON
BORE PIT
BORE PIT
A C-301
B C-301
C C-301
140'- 0"
EXCAVATE SWALE TO DAYLIGHT
OPEN TRENCH DIRECTIONAL DRILL
8" STORM DRAIN
1 LF @ 1.00%
POTHOLED SLOT FROM 7' TO 15' FROM FENCE TO 6.5' DEPTH
2- 1" ELECTRICAL
4" PVC SUBDRAIN
5' X 5' CONCRETE SLAB
TYPE B SUBDRAIN CLEANOUT
4" SUBDRAIN
ASSUMED CONNECTION
LOCATION
BORE PIT
6" LATERAL FOR DOWNSPOUT
8" X 6" TEE
6" LATERAL FOR
DOWNSPOUT
8" X 6" TEE
GRADE TO DRAIN TO
CLEANOUT
BORE PIT
TYPE B SUBDRAIN CLEAN OUT
RIM EL 719.00
INVERT EL 714.39
INVERT EL 716.97
WATTLE
EROSION CONTROL WATTLE (TYP)
REMOVE AND REPAIR CONCRETE FOUNDATION WALL AS NEEDED TO INSTALL 8" PIPE
WATTLE
8" STORM DRAIN 8 LF @ 1.00%
INVERT EL 709.20
EAST DOOR TO BE REMOVED AND OPENING SEALED PRIOR
TO CONSTRUCTION TO ALLOW FILL TO BE PLACED ALONG
NORTH WALL.
REMOVE AND REPAIR CONCRETE FOUNDATION WALL AS NEEDED TO INSTALL 8" PIPE
EL
EV
AT
IO
N
STATION
10+00 10+20
EL
EV
AT
IO
N
STATION
20+00 20+20
EL
EV
AT
IO
N
STATION
30+00 30+20
SE
C
TI
O
N S
AN
D
D
ET
AI
LS
C-301
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
NN
6" 90° ELBOW
6" DOWNSPOUT CONNECTION,
EXTEND 6" ABOVE GRADE
8" X 6" TEE
8" SLOTTED PVC
SECTION AT STA 0+95A SECTION AT STA 1+04B SECTION AT STA 1+96C
EXISTING SURFACE (ROCK SURFACING TO BE
REMOVED AND REPLACED BY MPCF STAFF)
3'- 0"
2'- 11"
VARIES
EXISTING 4" FOOTING DRAIN (TO REMAIN)
EXISTING BLDG WALL
ROCK SURFACING (TO BE REMOVED
AND REPLACED BY MPCF STAFF)
GEOTEXTILE (TYP)
POROUS BACKFILL
MATERIAL 3/4" CLEAN
MEETING IOWA DOT
GRADATION 29
EXISTING SURFACE
EXISTING FENCE FOOTING
(4'- 0" DEPTH)EXISTING SURFACE
REMOVE AND REPAIR CONCRETE
FOUNDATION WALL AS NEEDED TO
INSTALL 8" PIPE
EXISTING BLDG WALL
REGRADE TO DRAIN AWAY FROM BUILDING TO EDGE OF TRENCH
REGRADE TO DRAIN AWAY FROM BUILDING
PLACE 10-MIL PLASTIC SHEETING BELOW ROCK
SURFACING BETWEEN BUILDING AND TRENCH (TYP)
8" SLOTTED PVC
8" SOLID WALL PVC
8" SOLID WALL PVC
2 1/2
D
ET
AI
LS
C-501
6" MIN.
DETAIL- TYPE B CLEANOUT, PVCA
TYPE 4D CASTING GRATE
(SUDAS 6010.604)
6" CLASS 1 BEDDINGFILL CONCRETE TO INVERT
COLLECTOR PIPE TABLE
DOWNSTREAM
STRUCTURE
UPSTREAM
STRUCTURE
PIPE
DIA. (IN)
LENGTH
(FT) SLOPE (%) DOWNSTREAM
INVERT EL.
UPSTREAM
INVERT EL. COMMENT
PIPE APRON TYPE B CLEANOUT 8" 143.0 3.20 709.20 713.82 SOLID WALL PVC
TYPE B CLEANOUT TYPE B CLEANOUT 8" 49.0 1.00 713.93 714.43 SOLID WALL PVC
TYPE B CLEANOUT TYPE B CLEANOUT 8" 49.0 1.00 713.93 714.43 SLOTTED WALL PVC
TYPE B CLEANOUT TYPE A CLEANOUT 8" 84.0 1.00 716.97 717.80 SOLID WALL PVC
TYPE B CLEANOUT TYPE A CLEANOUT 8" 84.0 1.00 716.97 717.80 SLOTTED WALL PVC
STORM STRUCTURE TABLE
STRUCTURE NAME STATION TYPE GRADE EL. INVERT EL.
APRON 2+87.00 PIPE APRON, 8", METAL 709.96 709.2
TYPE B CLEANOUT 1+41.59 TYPE B CLEANOUT- 36" RCP 718.00 713.20
TYPE B CLEANOUT 0+88.28 TYPE B CLEANOUT- 36" RCP 719.00 713.80
TYPE A CLEANOUT 0+01.75 TYPE A CLEANOUT, 8", PVC 719.03 717.75
TYPE A CLEANOUT 0+01.75 TYPE A CLEANOUT, 8", PVC 719.03 717.75
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D O
C M
PC
F
IP
I B
U
IL
D
IN
G
ST
O R
M W
AT
ER
M
AN
AG
EM
EN
T
E W
AS
H
IN
G
TO
N
S T
M O
U N
T
PL
EA
SA
N T, IO
XX
X
BW
R
AN
SI
B
XX
-X
X-
XX
BW
R
7.
W
AT
ER
SM
IT
H E
N G
IN
EE
R
IN
G
M U
SC
AT
IN
E, IA
H
ER
SH
EY
A
VE
AD
M
IN
IS
TR
AT
IV
E
SE
R
VI
C
ES
E
AS
T W
AL
N
U T, H O
O
VE
R S
TA
TE
O
FF
IC
E
BU
IL
D
IN
G
FO
R B
ID
S
7/
/2
BW
R
IO
W
A D
EP
AR
TM
EN
T O
F
FI
R
ST
F
LO
O
R D
ES
M
O
IN
ES
, I
A
9-
R
EV
IS
ED
9/
6/
BW
R
OUTLET
DETAIL- PIPE APRON, METALB
Ø 8" I.D.
1'- 2 1/4"
1'- 4" 5 7/8"5 7/8"
3" MAX.
8" I.D.
8"
2"
4"
HOLES ON 12" CENTERS (MAX.)
TOE PLATE
FINISH EARTH SLOPE AS REQUIRED
Ø 8" I.D.
8"
TOE PLATE
INLET
REMOVABLE FORK, RODENT GUARD-
SEE SUDAS 4040.233 FOR DETAILS
36"
VARIES
| Sheets and Views |
| Layout1 |
| Sheets and Views |
| Layout1 |
| Sheets and Views |
| Layout1 |
| Sheets and Views |
| Layout |
| Sheets and Views |
| Layout |
| Sheets and Views |
| Layout |
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .