RFB927920-01 - WRC Decentralization Phase 2 & Myers Hall Fire Alarm & Sprinklers - Drawings.pdf
PDF 12 MB Posted
- Solicitation number
- RFB927900-01
- Issued by
- Scott County, Iowa
About this file
The document is a comprehensive set of architectural, mechanical, electrical, and fire protection drawings for the Iowa Department of Administrative Services' WRC Decentralization Phase 2 and Myers Hall Fire Alarm and Sprinkler project (Project Number 214220339), located at 1251 334th Street in Woodward, Iowa. The project involves extensive renovation and systems upgrades across multiple buildings, including mechanical system decentralization, fire alarm system upgrades, and fire sprinkler installations. The drawings are dated January 10, 2023, and represent 100% Construction Document (CD) phase plans covering basement, first, second, and third floor modifications for Westwood and Myers Hall facilities.
The project includes replacing existing steam heating systems with new hot water heating systems, installing new fin tube radiators, upgrading electrical infrastructure, implementing new fire alarm and sprinkler systems, and making associated architectural modifications. The planned work involves comprehensive demolition of existing mechanical, electrical, and fire protection systems, followed by installation of new infrastructure across multiple building spaces. Specific systems being upgraded include heating water pumps, boilers, unit heaters, fire alarm panels, electrical distribution, and fire protection components. The drawings indicate the work will be performed in compliance with multiple building codes, including the 2015 International Building Code, International Fire Code, and Americans with Disabilities Act requirements, with careful attention to preserving the historic character of the buildings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NUMBER MYERS HALL
ARCHITECTURAL
04-AD01 DEMOLITION PLANS
04-A110 BASEMENT AND FIRST FLOOR PLANS & DOORS
04-A111 SECOND FLOOR REFLECTED CEILING PLAN
PLUMBING
04-P100 PLUMBING PLANS
FIRE PROTECTION
04-FP000 FIRE PROTECTION GENERAL INFORMATION
04-FP100 BASEMENT FIRE PROTECTION PLAN
04-FP101 FIRST FLOOR FIRE PROTECTION PLAN
04-FP102 SECOND FLOOR FIRE PROTECTION PLAN
04-FP300 FIRE PUMP PLANS, DETAILS & SCHEDULES
MECHANICAL
04-MD100 BASEMENT MECHANICAL PIPING DEMOLITION PLAN
04-MD101 FIRST FLOOR MECHANICAL PIPING DEMOLITION PLAN
04-MD102 SECOND FLOOR MECHANICAL PIPING DEMOLITION PLAN
04-M100 BASEMENT MECHANICAL PIPING PLAN
04-M101 FIRST FLOOR MECHANICAL PIPING PLAN
04-M102 SECOND FLOOR MECHANICAL PIPING PLAN
04-M103 THERMOSTAT ZONING PLANS
04-M500 MECHANICAL DETAILS
04-M501 CONTROLS
04-M502 CONTROLS
04-M600 MECHANICAL SCHEDULES
ELECTRICAL
04-ED100 BASEMENT LEVEL ELECTRICAL DEMOLITION PLAN
04-ED101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN
04-ED102 SECOND FLOOR ELECTRICAL DEMOLITION PLAN
04-E100 BASEMENT LEVEL ELECTRICAL PLAN
04-E101 FIRST FLOOR ELECTRICAL PLAN
04-E102 SECOND FLOOR ELECTRICAL PLAN
04-E600 ELECTRICAL SCHEDULES
FIRE ALARM
04-ED300 BASEMENT LEVEL FIRE-ALARM DEMOLITION PLAN
04-ED301 FIRST FLOOR FIRE-ALARM DEMOLITION PLAN
04-ED302 SECOND FLOOR FIRE-ALARM DEMOLITION PLAN
04-E300 BASEMENT LEVEL FIRE-ALARM PLAN
04-E301 FIRST FLOOR FIRE-ALARM PLAN
04-E302 SECOND FLOOR FIRE-ALARM PLAN
I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE. I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL:
PRINTED OR TYPED NAME
SIGNATURE
MY LICENSE RENEWAL DATE IS JUNE 30,
DATE
ARCHITECT
LICENSE NUMBER
Eric E. Maguire
A SHEETS
07879
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL:
PRINTED OR TYPED NAME
SIGNATURE
MY LICENSE RENEWAL DATE IS DECEMBER 31,
DATE
LICENSE NUMBER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS
OF THE STATE OF IOWA.
Tyson L. Scheidecker
M, P, & FP SHEETS
21691
MECHANICAL ENGINEER
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL:
PRINTED OR TYPED NAME
SIGNATURE
MY LICENSE RENEWAL DATE IS DECEMBER 31,
DATE
LICENSE NUMBER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS
OF THE STATE OF IOWA.
Kevin J. Bruxvoort
E SHEETS
19927
ELECTRICAL ENGINEER
SHEET NUMBER WESTWOOD SHEET INDEX
ARCHITECTURAL
01-AD01 WESTWOOD DEMO FLOOR PLANS & DEMO REFLECTED CEILING PLANS
01-A101 WESTWOOD FLOOR PLANS & RCPs
MECHANICAL
01-MD100 BASEMENT MECHANICAL PIPING DEMOLITION PLAN
01-MD101 FIRST FLOOR MECHANICAL PIPING DEMOLITION PLAN
01-MD102 SECOND AND THIRD FLOOR MECHANICAL PIPING DEMOLITION PLAN
01-M100 BASEMENT MECHANICAL PIPING PLAN
01-M101 FIRST FLOOR MECHANICAL PIPING PLAN
01-M102 SECOND AND THIRD FLOOR MECHANICAL PIPING PLAN
01-M103 THERMOSTAT ZONING PLANS
01-M500 MECHANICAL DETAILS
01-M501 CONTROLS
01-M600 MECHANICAL SCHEDULES
ELECTRICAL
01-ED100 BASEMENT LEVEL ELECTRICAL DEMOLITION PLAN
01-ED101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN
01-ED102 SECOND AND THIRD FLOOR ELECTRICAL DEMOLITION PLAN
01-E100 BASEMENT LEVEL ELECTRICAL PLAN
01-E101 FIRST FLOOR ELECTRICAL PLAN
01-E102 SECOND AND THIRD FLOOR ELECTRICAL PLAN
FIRE ALARM
01-ED300 BASEMENT LEVEL FIRE ALARM DEMOLITION PLAN
01-ED301 FIRST FLOOR FIRE ALARM DEMOLITION PLAN
01-ED302 SECOND AND THIRD FLOOR FIRE ALARM DEMOLITION PLAN
01-E300 BASEMENT LEVEL FIRE ALARM PLAN
01-E301 FIRST FLOOR FIRE ALARM PLAN
01-E302 SECOND AND THIRD FLOOR FIRE ALARM PLAN
SEAL
W
E S
T O
W N
P K
W Y
S
U
IT
E
W E
S T
D E
S M
O
IN
E S
IA
.2
.8
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
SHEET INDEX CERTIFICATIONS
H
BA D E FC G H
Autodesk Revit 2021
/1
/2
:3 :1
P
M
A u to d e s k D o c s /I A
D A
S
W R
C P ro je c ts
/F ir e P u m p H o u s e -M
E P
-C e n t.
rv t
WRC Decentralization Phase 2 (#9279.20), Myers Hall Fire Alarm Phase 1 (#9294.00) & Fire Sprinkler (#9279.21) Iowa Department of Administrative Services 1251 334th St, Woodward, IA 50276
00-G000
W R
C D e c e n tr a liz a ti o n
P h a s e
.2
M y e rs
H a ll F ir e A la rm
P h a s e
.0
F ir e
S p ri n k le r
.2
Io w a D e p a rt m e n t o f
A d m in is tr a ti v e S e rv ic e s th
S t, W o o d w a rd
IA
P R
O J E
C T
N U
M B
E R
C D
IS
S
U E
D A
T E
-0
-1
SHEET NUMBER GENERAL SHEET INDEX
00-G000 COVER SHEET
00-G001 CAMPUS MAP
MECHANICAL & PLUMBING
00-MP00 MECHANICAL & PLUMBING GENERAL INFORMATION
ELECTRICAL
00-E000 ELECTRICAL GENERAL INFORMATION
SHEET NUMBER COTTAGE STYLE A
FIRE ALARM
C1-ED301 COTTAGE STYLE-A FIRE-ALARM DEMOLITION PLAN
C1-E301 COTTAGE STYLE-A FIRE-ALARM PLANS
SHEET NUMBER COTTAGE STYLE B
FIRE ALARM
C2-ED301 COTTAGE STYLE-B FIRE-ALARM DEMOLITION PLANS
C2-E301 COTTAGE STYLE-B FIRE-ALARM PLANS
SHEET NUMBER COTTAGE STYLE C
FIRE ALARM
C3-ED301 COTTAGE STYLE-C FIRE-ALARM DEMOLITION PLAN
C3-E301 COTTAGE STYLE-C FIRE-ALARM PLANS
SHEET NUMBER ADMIN BUILDING
FIRE ALARM
02-E301 ELECTRICAL ADMINSTRATION FIRE ALARM UPGRADES
Applicable Codes 2015 International Building Code as adopted by Iowa Administrative Rule 661-201 and 661-301 2015 International Fire Code as adopted by Iowa Administrative Rule 661-201 2015 International Residential Code as adopted by Iowa Administrative Rule 661-301 2012 International Energy Conservation Code as adopted by Iowa Administrative Rule 661-303 2015 International Existing Building Code as adopted by Iowa Administrative Rule 661-301 and 661-350 2012 NFPA 101 Life Safety Code as adopted by Iowa Administrative Rule 661-205 2010 Americans with Disabilities Act as adopted by Iowa Administrative Rule 661-302 Smoke Alarms/Detectors as adopted by Iowa Administrative Rule 661-210 (effective July 1, 2021) Carbon Monoxide Alarms as adopted by Iowa Administrative Rule 661-211 State Mechanical Code as adopted by the Department of Public Health Iowa Administrative Rule 641-61 State Plumbing Code as adopted by the Department of Public Health Iowa Administrative Rule 641-25 State Electrical Code as adopted by the State Electrical Licensing Board Iowa Administrative Rule 661-504 Westwood Occupancy: I-2 Construction Type: I-B Myers Occupancy: I-2, B Construction Type: I-B Cottages Occupancy: I-2
Life Safety
01-10-2023
01-10-2023
01-10-2023
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O J E
C T
N U
M B
E R
F
IE
L D
B O
O K
W
E S
T O
W N
P K
W Y
S
U
IT
E
W E
S T
D E
S M
O
IN
E S
IA
.2
.8
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2021
/1
/2
:3 :2
P
M
A u to d e s k D o c s /I A
D A
S
W R
C P ro je c ts
/F ir e P u m p H o u s e -M
E P
-C e n t.
rv t
C A
M P
U S
M A
P
C D
T L S
L D
F
-0
-1
00-G001
W R
C D e c e n tr a liz a ti o n
P h a s e
.2
M y e rs
H a ll F ir e A la rm
P h a s e
.0
F ir e
S p ri n k le r
.2
Io w a D e p a rt m e n t o f
A d m in is tr a ti v e S e rv ic e s th
S t, W o o d w a rd
IA
►8" HWS PIPE SIZE, SYSTEM, AND FLOW TAG (DIAMETER)
EXISTING TO REMAIN
TO BE DEMOLISHED
HEATING WATER RETURN
HEATING WATER SUPPLY
HIGH PRESSURE STEAM
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
BALANCING VALVE
BALL VALVE
CHECK VALVE
THREE WAY VALVE
MOTORIZED CONTROL VALVE
THREE WAY MOTORIZED CONTROL VALVE
PRESSURE REDUCING VALVE
SOLENOID VALVE
BUTTERFLY VALVE
MECHANICAL SYMBOLS LIST
ELBOW UP
ELBOW DOWN
PIPE OFFSET UP
PIPE OFFSET DOWN
PIPE TEE TURNED UP
PIPE TEE TURNED DOWN
PIPE TEE
PIPE CAP
PIPE UNION
PIPE TRANSITION
KEYNOTE
CAP EXISTING PIPE OR DUCT
NEW CONNECTION INTO EXISTING PIPE OR DUCT
DETAIL NUMBER
SHEET NUMBER ON
WHICH THE DETAIL
RESIDES
LPS
LPC
HPS
HWS
HWR
HWS
HWS
THERMOSTAT T
GENERAL MECHANICAL ABBREVIATIONS
SYMBOLS
& AND
@ AT
# NUMBER or POUND
A
A/E ARCHITECT/ENGINEER
AD ACCESS DOOR
ADJ ADJUSTABLE/ADJACENT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
AP ACCESS PANEL
APPROX APPROXIMATE(LY)
AS AIR SEPARATOR
AVG AVERAGE
B
BAS BUILDING AUTOMATION SYSTEM
BFF BELOW FINISHED FLOOR
BFBP BOILER FEED BOOSTER PUMP
BHP BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
C
CAP CAPACITY
CFM CUBIC FEET PER MINUTE
CFH CUBIC FEET PER HOUR
CH CHILLER
CHP CHILLED WATER PUMP
CHSP CHILLED WATER SECONDARY PUMP
CIRC CIRCULATING
CLG CEILING
CONT CONTINUATION
CONTR CONTRACTOR
CONV CONVECTOR
COORD COORDINATE
CTRL CONTROL
CU COPPER
CUH CABINET UNIT HEATER
D
°/DEG DEGREE
°C DEGREES CELSIUS
°F DEGREES FAHRENHEIT
DB DRY BULB
DDC DIRECT DIGITAL CONTROLS
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGRAM
DWG DRAWING
E
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ET EXPANSION TANK
EWB ENTERING WET BULB
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F
FS FLOW SWITCH
FT FINNED TUBE RADIATION
FTHD FOOT HEAD OR PRESSURE DROP
G
GA GAUGE
GAL GALLON
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H
HP HORSEPOWER
HPR HIGH PRESSURE STEAM RETURN
HPS HIGH PRESSURE STEAM SUPPLY
HTG HEATING
HVAC HEATING, VENTILATION, AIR CONDITIONING
HX HEAT EXCHANGER
HZ HERTZ (FREQUENCY)
I
ID INSIDE DIAMETER
IN INCHES
IN WC INCHES (WATER COLUMN)
INS INSULATION
INSTR INSTRUMENT
ISO ISOMETRIC
K
KW KILOWATT
KWH KILOWATT HOUR
L
LAT LEAVING AIR TEMPERATURE
LB(S) POUND(S)
LDB LEAVING DRY BULB (TEMP)
LWB LEAVING WET BULB (TEMP)
LWT LEAVING WATER TEMPERATURE
M
MAINT MAINTENANCE
MAX MAXIMUM
MBH BRITISH THERMAL UNIT (1000/HR)
MC MECHANICAL CONTRACTOR
MCC MOTOR CONTROL CENTER
MCA MINIMUM CIRCUIT AMPS
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM OR MINUTE
MISC MISCELLANEOUS
N
NA NOT APPLICABLE
NC NORMALLY CLOSED OR NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
O
OD OUTER DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
P
PG PRESSURE GAUGE
PH PHASE
PSIG POUNDS PER SQUARE INCH GAUGE
R
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RPM REVOLUTIONS PER MINUTE
S
SCH SCHEDULE
SCHM SCHEMATIC
SHT SHEET
SPEC SPECIFICATION(S)
SQ IN SQUARE INCH
SV SAFETY VALVE
SYS SYSTEM
SRV SAFETY RELIEF VALVE
T
T THERMOSTAT
TCC TEMPERATURE CONTROL CONTRACTOR
TEMP TEMPERATURE OR TEMPORARY
THRU THROUGH
TP TOTAL PRESSURE
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
W
W/ WITH
W/O WITHOUT
WB WET BULB
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
1. UNLESS NOTED OTHERWISE: LIGHT LINES DENOTE EXISTING PIPING, OR EQUIPMENT WHICH
IS TO REMAIN. BOLD LINES INDICATE NEW WORK TO BE INSTALLED UNDER THIS CONTRACT.
2. PLUMBING SHOWN IS IN SCHEMATIC FORM. NOT ALL RISERS AND DROPS ARE SHOWN.
PROVIDE OFFSETS AS REQUIRED TO MEET SPACE REQUIREMENTS AND TO AVOID
INTERFERENCE WITH OTHER TRADES. THE CONTRACTOR SHALL PROVIDE COMPLETE FULLY
FUNCTIONAL SYSTEMS.
3. ALL EQUIPMENT AND ACCESSORIES SHALL BE INSTALLED TO BE EASILY ACCESSIBLE.
4. PLUMBING WORK SHALL BE COORDINATED WITH OTHER TRADES, INCLUDING BUT NOT
LIMITED TO DUCTWORK, ELECTRICAL EQUIPMENT, PIPING AND FIRE PROTECTION. SPACE
ABOVE CEILING IS LIMITED AND SHALL BE COORDINATED WITH OTHER TRADES.
5. ALL WORK WITHIN THE CONTRACT DOCUMENTS, WHICH INCLUDE THIS DRAWING, SHALL BE
COMPLETED IN A SAFE WORKMANLIKE MANNER AND IN ACCORDANCE WITH ALL
APPLICABLE STATE, LOCAL AND NATIONAL CODES, REGULATIONS AND ORDINANCES. IF ANY
CONFLICTS ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE CODES,
REGULATIONS OR ORDINANCE, THE CONTRACTOR SHALL BE RESPONSIBLE TO HAVE ALL
WORK CONFORM TO THE STRICTER OF SAID REQUIREMENTS.
6. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS AS
REQUIRED FOR ELECTRICAL, FIRE PROTECTION, PLUMBING, MECHANICAL AND BACKFLOW
PREVENTION INSTALLATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
PROVIDE BOTH A COMPLETE AND COMPLIANT INSTALLATION AS MAY BE DETERMINED BY
THE AUTHORITY(S) HAVING JURISDICTION.
7. CONTRACTOR SHALL NOT PROCURE OR FABRICATE ANY PIPING, DUCTWORK OR OTHER
EQUIPMENT WITHOUT FIRST VERIFYING ALL DIMENSIONS AND CONDITIONS WHETHER
CURRENTLY EXISTING OR NOT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK,
INCLUDING ANY REQUIRED REWORK.
8. MAINTAIN ALL MANUFACTURER RECOMMENDED EQUIPMENT SERVICE AND SAFETY
CLEARANCES. DO NOT LOCATE ANY EQUIPMENT OR RUN MATERIALS ABOVE ANY
ELECTRICAL PANELS OR SWITCHGEAR. MAINTAIN ALL NFPA/NEC CODE REQUIRED
CLEARANCES.
9. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING, SCHEDULING AND
SEQUENCING OF THEIR WORK WITH ALL OTHER TRADES. PROVIDE OFFSETS, EASEMENTS,
OR RELOCATE TO AVOID CONFLICTS WITH WORK OF OTHER TRADES. FURNISH SUFFICIENT
RESOURCES TO MEET ALL PROJECT MILESTONES AND DEADLINES.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE WATERTIGHT AND WEATHER-
PROOF INTEGRITY OF ROOFS, WALLS AND FLOORS DURING CONSTRUCTION. EACH TRADE
SHALL LOCATE/DIMENSION/COORDINATE THEIR ROOF, FLOOR AND WALL OPENINGS WITH
THE GENERAL CONTRACTOR (GC) OR CONSTRUCTION MANAGER.
11. PROTECT NEW WORK FROM DAMAGE OR DECONTAMINATION. PROVIDE TEMPORARY
PROTECTIVE CAPPING OR TAPED POLYETHYLENE ENCLOSURES OVER OPEN DUCTWORK
AND PIPING ENDS AND EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING
MECHANICAL SYSTEMS PRIOR TO PLACING THEM IN SERVICE.
12. IN A NEAT AND WORKMANLIKE MANNER: PATCH ANY REMAINING OPENINGS AND FILL
EXCESSIVE GAPS; REWORK AND REFINISH TO MATCH ADJACENT STRUCTURES; FLASH AND
SEAL ALL MECHANICAL AND ELECTRICAL PENETRATIONS THRU WALLS, CEILINGS AND
FLOORS WITH METAL FRAMEWORK OR ESCUTCHEONS. ALL OPENINGS SHALL BE PROPERLY
SEALED SO AS TO MEET FIRE RATING NEEDS.
GENERAL PLUMBING NOTES
1. THIS DRAWING DIAGRAMMATICALLY REPRESENTS THE LAYOUT OF EXISTING CONDITIONS
WITH MAJOR PLUMBING COMPONENTS. THEY ARE NOT INTENDED TO SHOW ACCESSORIES
OR INCIDENTALS COMMON TO EQUIPMENT INDICATED, THOUGH THESE ITEMS ARE TO BE
REMOVED, ACCESSIBILITY TO DEMOLITION ITEMS SHALL NOT BE INFERRED. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF BUILDING AND EXISTING
CONDITIONS, PRIOR TO BID SUBMISSION.
2. EXISTING PIPING PENETRATIONS VACATED/REVEALED DURING DEMOLITION AND REMODEL
SHALL BE INFILLED AND FINISHED TO MATCH EXISTING. IF MATERIALS FOR REPAIR TO MATCH
EXISTING ARE NOT AVAILABLE (IE GLAZED WALL TILE), GROUT ABANDONED PENETRATION
FULL AND FINISH FLUSH. PRIOR APPROVAL OF THE OWNER MUST BE OBTAINED BEFORE ANY
PROPOSED NON-SIMILAR FINISH WORK BEGINS.
3. DISCONNECT AND REMOVE ALL PREVIOUSLY ABANDONED PIPING WITHIN THE PROJECT
AREA. REMOVE EXISTING/ABANDONED HANGERS AND SUPPORTS IF DEEMED NOT REUSABLE.
4. ALL PIPING SHOWN IS BASED ON ORIGINAL DRAWINGS AND LIMITED SITE OBSERVATIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR
TO COMMENCING WORK.
5. ALL PIPING ASSOCIATED WITH EXISTING SYSTEMS SHALL BE DEMOLISHED. NO PIPING SHALL
BE ABANDONED.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR DRAINING PIPING SYSTEMS TO BE CUT, CAPPED
OR REMOVED. DISCHARGE FROM SUCH SYSTEMS SHALL BE APPROPRIATELY DISPOSED OF
PER FEDERAL, STATE AND LOCAL REQUIREMENTS.
7. COORDINATE WITH GENERAL CONTRACTOR FOR FLOOR, WALL AND ROOF PATCHING
REQUIRED DUE TO PENETRATIONS RESULTING FROM DEMOLITION OF EXISTING AND
INSTALLATION OF NEW EQUIPMENT AND COMPONENTS.
8. CONTRACTOR IS RESPONSIBLE TO VERIFY ACTUAL NUMBER AND LOCATION OF SYSTEMS
AND COMPONENTS TO BE DEMOLISHED AND REMOVED.
9. TO MINIMIZE DISRUPTIONS, COORDINATE ALL DEMOLITION WITH OWNER, GENERAL
CONTRACTOR, OR CONSTRUCTION MANAGER BEFORE SHUTTING DOWN ANY UTILITY OR
SIMILAR SYSTEM. SHUTDOWNS FOR UTILITIES OR SIMILAR SYSTEMS SHALL BE REQUESTED
WELL IN ADVANCE PER THE SPECIFICATION.
10. ALL WORK WITHIN THE CONTRACT DOCUMENTS, WHICH INCLUDE THIS DRAWING, SHALL BE
COMPLETED IN A SAFE WORKMANLIKE MANNER AND IN ACCORDANCE WITH ALL APPLICABLE
STATE, LOCAL AND NATIONAL CODES, REGULATIONS AND ORDINANCES. IF ANY CONFLICTS
ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE CODES, REGULATIONS
OR ORDINANCE, THE CONTRACTOR SHALL BE RESPONSIBLE TO HAVE ALL WORK CONFORM
TO THE STRICTER OF SAID REQUIREMENTS.
11. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS AS
REQUIRED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE BOTH A
COMPLETE AND COMPLIANT INSTALLATION AS MAY BE DETERMINED BY THE AUTHORITY(S)
HAVING JURISDICTION.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE WATERTIGHT AND WEATHER-
PROOF INTEGRITY OF ROOFS, WALLS AND FLOORS DURING CONSTRUCTION. EACH TRADE
SHALL LOCATE/DIMENSION/COORDINATE THEIR ROOF, FLOOR AND WALL OPENINGS WITH
THE GENERAL CONTRACTOR (GC) OR CONSTRUCTION MANAGER.
GENERAL PLUMBING DEMOLITION NOTES
PIPE SIZE AND SYSTEM TAG (DIAMETER)
EXISTING TO REMAIN
TO BE DEMOLISHED
DOMESTIC COLD WATER
NATURAL GAS
SANITARY SEWER
SANITARY VENT
BALANCING VALVE
BALL VALVE
PLUMBING SYMBOLS LIST
2" CW
V
SAN
NG
CW
SAN
SAN
ELBOW UP
ELBOW DOWN
PIPE OFFSET UP
PIPE OFFSET DOWN
PIPE TEE TURNED UP
PIPE TEE TURNED DOWN
PIPE TEE
PIPE CAP
PIPE UNION
PIPE TRANSITION
KEYNOTE
CAP EXISTING PIPE
NEW CONNECTION INTO EXISTING PIPE
DETAIL NUMBER
SHEET NUMBER ON
WHICH THE DETAIL
RESIDES
6" CW UP
6" HW DN
GENERAL PLUMBING ABBREVIATIONS
SYMBOLS
& AND
@ AT
# NUMBER or POUND
A
ADJ ADJUSTABLE/ADJACENT
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
AMB AMBIENT
AP ACCESS PANEL
APPROX APPROXIMATE(LY)
AS AIR SEPARATOR
ASSY ASSEMBLY
ATM ATMOSPHERE
AUX AUXILIARY
AVG AVERAGE
B
BAS BUILDING AUTOMATION SYSTEM
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BOP BOTTOM OF PIPE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
C
C COMPRESSOR (AIR)
CAL CALIBRATE
CAP CAPACITY
CCW COUNTER CLOCKWISE
CIP CAST IRON PUMP
CIRC CIRCULATING
CL CENTER LINE
CLG CEILING
CLR CLEAR(ANCE)
CLW CLOCKWISE
CO CLEANOUT
COND CONDENSATE
CONSTR CONSTRUCTION
CONT CONTINUATION
CONTR CONTRACTOR
COORD COORDINATE
CTRL CONTROL
CU COPPER
CU FT CUBIC FEET
CU IN CUBIC INCH
D
°/DEG DEGREE
°F DEGREES FAHRENHEIT
DB DRY BULB
DDC DIRECT DIGITAL CONTROLS
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGRAM
DN DOWN
DR DRAIN
DV DRAIN VALVE
DWG DRAWING
E
EA EACH
EER ENERGY EFFICIENCY RATIO
EF ENERGY FACTOR
ELEV ELEVATION
ELEC ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FPT FEMALE PIPE THREAD
FS FLOOR SINK
G
G GAS
GA GAUGE
GAL GALLON
GC GENERAL CONTRACTOR
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GWH GAS FIRED WATER HEATER
H
H&CW HOT AND COLD WATER
HORIZ HORIZONTAL
HP HORSEPOWER
HVAC HEATING, VENTILATION, AIR CONDITIONING
HZ HERTZ (FREQUENCY)
I
ID INSIDE DIAMETER
IN INCHES
IN WC INCHES (WATER COLUMN)
INS INSULATION
INSTR INSTRUMENT
IP IRON PIPE
IPS IRON PIPE SIZE
ISO ISOMETRIC
K
KW KILOWATT
KWH KILOWATT HOUR
L
LAV LAVATORY
LB(S) POUND(S)
LWT LEAVING WATER TEMPERATURE
M
MAINT MAINTENANCE
MAX MAXIMUM
MBH BRITISH THERMAL UNIT (1000/HR)
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPS
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM OR MINUTE
MISC MISCELLANEOUS
MPT MALE PIPE THREAD
N
NA NOT APPLICABLE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NPT NATIONAL PIPE THREAD
NTS NOT TO SCALE
O
OD OUTER DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
P
PG PRESSURE GAUGE OR PROPYLENE GLYCOL
PH PHASE
PLBG PLUMBING
PRV PRESSURE RELIEF VALVE OR PRESSURE
REGULATING VALVE
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
R
RD ROOF DRAIN
RECIRC RECIRCULATE(ING)
REQD REQUIRED
RHC REHEAT COIL
RPM REVOLUTIONS PER MINUTE
S
SCH SCHEDULE
SCHM SCHEMATIC
SF SQUARE FEET
SHT SHEET
SK SINK
SP SUMP PUMP OR STATIC PRESSURE
SPEC SPECIFICATION(S)
SQ IN SQUARE INCH
SS STAINLESS STEEL
STBY STANDBY
STD STANDARD
STL STEEL
SUCT SUCTION
SV SAFETY VALVE
SYS SYSTEM
SRV SAFETY RELIEF VALVE
T
T THERMOSTAT
TD TRENCH DRAIN
TEMP TEMPERATURE OR TEMPORARY
THRU THROUGH
TOP TOP OF PIPE
TYP TYPICAL
U
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITY
V
VAC VACUUM
VBX VALVE BOX
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THRU ROOF
W
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET
WH WATER HEATER OR WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
SEAL
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O J E
C T
N U
M B
E R
F
IE
L D
B O
O K
W
E S
T O
W N
P K
W Y
S
U
IT
E
W E
S T
D E
S M
O
IN
E S
IA
.2
.8
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2022
W R
C D e c e n tr a liz a ti o n P h a s e
.2
/1
/2
:4 :3
P
M
A u to d e s k D o c s /I A
D A
S
W R
C P ro je c ts
/W e s tw o o d -M
E P
-R
M a s te r.
rv t
M E
C H
A N
IC
A
L
P L U
M B
IN
G
G E
N E
R A
L
IN
F O
R M
A T
IO
N
C D
T L S
C A
S
-0
-1
00-MP00
Io w a D e p a rt m e n t o f
A d m in is tr a ti v e S e rv ic e s th
S t, W o o d w a rd
IA
1. LIGHT LINES INDICATE EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. TO
REMAIN. BOLD LINES INDICATE PIPING, DUCTWORK, EQUIPMENT, ETC. TO
BE INSTALLED BY THIS CONTRACT UNLESS NOTED OTHERWISE.
2. COORDINATE ROUGH-IN AND FINAL LOCATION OF DUCTWORK AND PIPING
WITH LIGHTING, STRUCTURE, SPRINKLERS, ETC. PROVIDE OFFSETS
AND/OR EASEMENTS, OR RELOCATE AS REQUIRED AVOIDING CONFLICTS
WITH WORK OF OTHER TRADES.
3. PROVIDE TEMPORARY FILTRATION ON RETURNS DURING CONSTRUCTION
TO PREVENT DUST FROM SPREADING TO DUCTWORK, HVAC EQUIPMENT,
AND NON-CONSTRUCTION AREAS.
4. PIPING IS SHOWN IN SCHEMATIC FORM. ROUTE AS REQUIRED FOR
CLEARANCE. VERIFY ROUTING AND CLEARANCES AND COORDINATE WITH
OTHER TRADES PRIOER TO FABRICATION.
5. BREAK CONNECTIONS ARE REQUIRED AT ALL MAJOR EQUIPMENT AND
PIPING ITEMS THAT REQUIRE REMOVAL FOR MAINTENANCE.
6. PIPE REDUCTIONS ON HORIZONTAL PIPING GOING FROM LARGER TO
SMALLER SHALL BE MADE WITH ECCENTRIC REDUCERS: TOP FLAT FOR
LIQUID SYSTEMS, CONCENTRIC REDUCERS MAY BE USED FOR FLOW
GOING FROM SMALL TO LARGER SIZE PIPE.
7. FIRE SAFE ALL PIPE PENETRATIONS PER UL AT RATED WALLS.
8. THERMOSTATS SHALL BE MOUNTED 4'-0" ABOVE FINISHED FLOOR.
9. NEW FLOOR/WALL/CEILING PENETRATIONS REQUIRED FOR MECHANICAL
PIPING INSTALLATION SHALL BE CLEANLY BORED AT RIGHT ANGLES. AS
NEW PIPING IS INSTALLED, NEW PIPING PENETRATIONS SHALL BE NEATLY
CAULKED TO FILL VOID. EXPOSED WALL PENETRATIONS SHALL BE
FINISHED WITH ESCUTCHEONS.
10. ALL NEW PIPING EXPOSED IN OCCUPIED SPACES SHALL HAVE PVC
JACKETS INSTALLED OVER THE PIPING INSULATION. ANY PIPING
REQUIRED TO BE EXPOSED SHALL BE INSTALLED VERTICALLY OR
HORIZONTALLY IN LEAST VISIBLE LOCATIONS.
11. ALL NEW EQUIPMENT AND ACCESSORIES (CIRCUIT SETTERS,
CIRCULATION PUMPS, EXPANSION TANKS, ETC.) SHALL BE INSTALLED TO
BE EASILY ACCESSIBLE.
12. ALL CONDENSATE PIPING SHALL BE SLOPED 1/8" PER FOOT MINIMUM.
13. CONTRACTOR SHALL PATCH/REPAIR ALL UNUSED OPENINGS AND
MODIFIED FINISH SURFACES. PATCHING SHALL MATCH MATERIALS,
FINISH, AND TEXTURE OF ADJACENT SURFACES.
14. PATCH ANY REMAINING OPENINGS AND FILL EXCESSIVE GAPS. REWORK
AND REFINISH TO MATCH ADJACENT STRUCTURES. FLASH AND SEAL ALL
MECHANICAL AND ELECTRICAL PENETRATIONS THRU WALLS, CEILINGS,
AND FLOORS WITH METAL FRAMEWORK OR ESCUTCHEONS. ALL
OPENINGS SHALL BE PROPERLY SEALED TO MEET FIRE RATING NEEDS.
15. HEATING AND WATER BRANCH PIPING TO TERMINAL HEATING DEVICES
SHALL BE 3/4" PIPE SIZE UNLESS OTHERWISE NOTED.
16. NEW WORK HAS BEEN SHOWN DIAGRAMMATICALLY AND DUE TO THE
LIMITED SCALE OF THESE DRAWINGS, THE PLACEMENT AND ROUTING OF
ALL DUCTWORK, PIPING, ETC. IS CONSIDERED SCHEMATIC IN NATURE.
THEREFORE, THE DRAWINGS MAY NOT SHOW ALL OFFSETS AND
TRASITIONS, WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL
PROVIDE COMPLETE FULLY FUNCTIONAL SYSTEMS.
17. ALL WORK WITHIN THE CONTRACT DOCUMENTS SHALL BE COMPLETED IN
A SAFE MANNER AND IN ACCORDANCE WITH ALL APPLICABLE STATE AND
NATIONAL CODES, REGULATIONS, AND ORDINANCES. IF ANY CONFLICTS
ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE
CODES, REGULATIONS, OR ORDINANCES, THE CONTRACTOR SHALL BE
RESPONSIBLE TO HAVE ALL WORK CONFORM TO THE STRICTER OF SAID
REQUIREMENTS.
18. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS AS REQUIRED FOR ELECTRICAL, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND BACKFLOW PREVENTION INSTALLATIONS.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE BOTH A
COMPLETE AND COMPLIANT INSTALLATION AS MAY BE DETERMINED BY
THE AUTHORITY/AUTHORITIES HAVING JURISDICTION.
19. CONTRACTOR SHALL NOT PROCURE OR FABRICATE ANY PIPING,
DUCTWORK, OR OTHER EQUIPMENT WITHOUT FIRST VERIFYING ALL
DIMENSIONS AND CONDITIONS WHETHER CURRENTLY EXISTING OR NOT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK, INCLUDING
ANY REQUIRED REWORK.
20. MAINTAIN ALL MANUFACTURER RECOMMENDED EQUIPMENT SERVICE
AND SAFETY CLEARANCES. DO NOT LOCATE ANY EQUIPMENT OR RUN
MATERIALS ABOVE ANY ELECTRICAL PANELS OR SWITCHGEAR. MAINTAIN
ALL NFPA/NEC/CODE REQUIRED CLEARANCES.
21. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING,
SCHEDULING, AND SEQUENCING OF THEIR WORK WITH ALL OTHER
TRADES. PROVDE OFFSETS, EASEMENTS, OR RELOCATE AS REQUIRED
AVOIDING CONFLICTS WITH WORK OF OTHER TRADES. FURNISH
SUFFICIENT RESOURCES TO MEET ALL PROJECT MILESTONES AND
DEADLINES.
22. PROTECT WORK FROM DAMAGE OR CONTAMINATION. PROVIDE
TEMPORARY PROTECTIVE CAPPING OR TAPED POLYETHYLENE
ENCLOSURES OVER OPEN DUCTWORK AND PIPING ENDS AND
EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING
MECHANICAL SYSTEMS PRIOR TO PLACING THEM IN SERVICE.
23. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE
WATERTIGHT AND WEATHER-PROOF INTEGRITY OF ROOFS, WALLS, AND
FLOORS DURING CONSTRUCTION. EACH TRADE SHALL
LOCATE/DIMENSION/COORDINATE THEIR ROOF, FLOOR, AND WALL
OPENINGS AS NEEDED WITH THE GENERAL CONTRACTOR OR
CONSTRUCTION MANGER.
GENERAL MECHANICAL NOTES
1. THESE DRAWINGS REPRESENT THE LAYOUT OF EXISTING CONDITIONS OF
MAJOR COMPONENTS. THEY ARE NOT INTENDED TO SHOW ACCESSORIES
OR INCIDENTALS COMMON TO THE COMPONENTS INDICATED, THOUGH
THESE ITEMS ARE TO BE REMOVED. ACCESSIBILITY TO DEMOLITIUON ITEMS
SHALL NOT BE INFERRED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
FIELD VERIFICATION OF BUILDING AND EXISTING CONDITIONS PRIOR TO BID
SUBMISSION.
2. DEMOLITION WORK SHOWN IS BASED ON LIMITED SITE OBSERVATIONS AND
CONSTRUCTION/RECORD DOCUMENTS. CONTRACTOR SHALL NOT
DEMOLISH ANY MECHANICAL PIPING, DUCTWORK, EQUPIMENT, OR OTHER
ITEMS WITHOUT FIRST VERIFYING EXISTING CONDITIONS. CONSULT
OWNER'S REPRESENTATIVE OR CONSTRUCTION MANAGER BEFORE START
OF WORK.
3. DEMOLITION OF MECHANICAL PIPING, DUCTWORK, AND EQUIPMENT SHALL
INCLUDE ALL HANGERS, FITTINGS, DAMPERS, VALVES, ETC.
4. REPAIR ANY INSULATION DAMAGED DURING REMOVAL. REPAIR WORK TO
MATCH EXISTING.
5. COORDINATE WALL AND FLOOR PATCHING REQUIREMENTS. PATCHWORK
SHALL MATCH MATERIALS, FINISH, AND TEXTURE OF ADJACENT SURFACES.
6. CONTRACTOR SHALL PATCH/REPAIR ALL UNUSED OPENINGS AND MODIFIED
FINISH SURFACES. PATCH SHALL MATCH MATERIALS, FINISH, AND TEXTURE
OF ADJACENT SURFACES.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER AND TIMELY DISPOSAL
OF ALL CONSTRUCTION DEBRIS INCLUDING BUT NOT LIMITED TO EQUIPMENT
AND MATERIALS NOT CLAIMED BY OWNER.
8. IT IS ESSENTIAL TO MINIMIZE DISRUPTIONS. COORDINATE ALL DEMOLITION
WITH THE OWNER OR CONSTRUCTION MANAGER BEFORE SHUTTING DOWN
ANY UTILITY OR SIMILAR SYSTEM. SHUTDOWN OF UTILITIES OR SIMILAR
SYSTEMS SHALL BE REQUESTED WELL IN ADVANCE AND PRE-APPROVED BY
THE PROPER AUTHORITY AND/OR AUTHORITIES HAVING JURISDICTION
BEFORE WORK BEGINS.
9. ALL WORK WITHIN THE CONTRACT DOCUMENTS SHALL BE COMPLETED IN A
SAFE MANNER AND IN ACCORDANCE WITH ALL APPLICABLE STATE AND
NATIONAL CODES, REGULATIONS, AND ORDINANCES. IF ANY CONFLICTS
ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE APPLICABLE CODES,
REGULATIONS, OR ORDINANCES, THE CONTRACTOR SHALL BE
RESPONSIBLE TO HAVE ALL WORK CONFORM TO THE STRICTER OF SAID
REQUIREMENTS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE WATERTIGHT
AND WEATHERPROOF INTEGRITY OF ROOFS, WALLS, AND FLOORS DURING
CONSTRUCTION. EACH TRADE SHALL LOCATE/DIMENSION/COORDINATE
THEIR ROOF, FLOOR, AND WALL OPENINGS AS NEEDED WITH THE
CONSTRUCTION MANAGER.
11. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS AS REQUIRED FOR ELECTRICAL, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND BACKFLOW PREVENTION INSTALLATIONS. IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE BOTH A
COMPLETE AND COMPLIANT INSTALLATION AS MAY BE DETERMINED BY THE
AUTHORITY AND/OR AUTHORITIES HAVING JURISDICTION.
12. PROVIDE TEMPORARY SPACE TEMPERING (HEATING/COOLING/DE-
HUMIDIFICATION) AS NEEDED TO PROTECT SPACES AND INSTALLATIONS
FROM EXPOSURE TO DAMAGING CONDITIONS.
GENERAL MECHANICAL DEMOLITION NOTES
1. PIPING IS SHOWN IN SCHEMATIC FORM. ROUTE AS REQUIRED FOR CLEARANCE
WITH EXISTING CONDITIONS AND OTHER TRADES.
2. UNIONS AND VALVES TO BREAK CONNECTIONS ARE REQUIRED AT ALL MAJOR
EQUIPMENT AND ALL PIPING ITEMS THAT REQUIRE REMOVAL FOR MAINTENANCE.
3. PIPE REDUCTIONS ON HORIZONTAL PIPING GOING FROM LARGER TO SMALLER
SHALL BE MADE WITH ECCENTRIC REDUCERS. TOP FLAT FOR LIQUID SYSTEMS.
CONCENTRIC REDUCERS MAY BE USED FOR FLOW GOING FROM SMALL TO
LARGER SIZE PIPE.
4. FIRE SAFE ALL PIPE PENETRATIONS PER UL AT RATED WALLS AND FLOORS.
5. REFER TO DETAILS FOR ADDITIONAL INFORMATION.
6. FLOOR/WALL/CEILING PENETRATIONS REQUIRED FOR MECHANICAL PIPING
INSTALLATION SHALL BE CLEANLY BORED AT RIGHT ANGLES. AS NEW PIPING IS
INSTALLED, NEW PIPING PENETRATIONS SHALL BE NEATLY CAULKED TO FILL VOID.
EXPOSED WALL PENETRATIONS SHALL BE FINISHED WITH ESCUTCHEONS.
7. ALL NEW EQUIPMENT AND ACCESSORIES (CIRCUIT SETTERS, CIRCULATION
PUMPS, EXPANSION TANKS, ETC.) SHALL BE INSTALLED TO BE EASILY ACCESSIBLE.
ALL ALREANACES FOR EQUIPMENT PER MANUFACTURERS' INSTRUCTIONS SHALL
BE REQUIRED.
8. CONNECTIONS BETWEEN DISSIMILAR PIPING MATERIALS SHALL BE MADE USING
DIELECTRIC FITTINGS.
9. THERMOSTATS SHALL BE MOUNTED AT 4'-0" ABOVE FINISHED FLOOR.
10. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
GENERAL MECHANICAL PIPING NOTES
HT AFF SYMBOL DESCRIPTION
EM
E E
K
D
OS
MC
T
SP
M
UC
CLG
A
A
P
E
J J
T
25 KVA
1 SF-1
M
R
OS IR
LS A
PC
W
X
TV
SS
S S
S
V
IC
FS
TS
F
F
F
F 110cd
F
F 110cd
F
F S 110cd
FA ANNUN
FACP
FARP
P P
R/F135 R/F135
P
F
DH
CH
FR
FB 1
ASD
DR
TV
TRACK AND TRACK LIGHT (TYPE DENOTED)AS NOTED
EMERGENCY BATTER LIGHT (TYPE DENOTED)96"
EXIT SIGN (TYPE DENOTED)
LIGHT FIXTURE ON EMERGENCY CIRCUITAS NOTED
SINGLE POLE SWITCH
3-WAY SWITCH
48"
48"
4-WAY SWITCH48"
KEYED SWITCH48"
DIMMER SWITCH48"
OCCUPANCY SENSOR SWITCH48"
MOMENTARY CONTACT SWITCH48"
TIMER SWITCH48"
FAN SPEED CONTROL48"
MOTOR HORSEPOWER RATED SWITCH48"
PUSH BUTTON48"
DURESS PUSH BUTTON, UNDER COUNTER48"
DUPLEX RECEPTACLE18" UNO
FOURPLEX RECEPTACLE18" UNO
FLOOR BOX (TYPE DENOTED)
CEILING MOUNTED DUPLEX RECEPTACLE
HT AFF SYMBOL DESCRIPTION
SURFACE RACEWAY (TYPE DENOTED)18"
CLOCK (TYPE DENOTED)
POWER POLE (OPEN OFFICE STYLE)
ELECTRICAL CONNECTION (SEE SCHEDULE)
JUNCTION BOXAS NOTED
CIRCUIT BREAKER PANEL72"**
POWER OR DISTRIBUTION PANEL72"**
SPECIAL CABINET (TYPE DENOTED)72"**
TRANSFORMER (TYPE DENOTED)
GENERATOR (KVA DENOTED)
MOTOR (SEE SCHEDULE)
MOTORIZED DAMPER
SAFETY DISCONNECTION SWITCH72"**
ADJUSTABLE SPEED DRIVE
RELAY72"**
OCCUPANCY SENSOR (TYPE DENOTED)
LIGHT LEVEL SENSOR (TYPE DENOTED)
SM
PHOTOCELLAS NOTED
CCTV CAMERA (TYPE DENOTED)AS NOTED
SURVEILLANCE MONITOR
HT AFF SYMBOL DESCRIPTION HT AFF SYMBOL DESCRIPTION
CONDUIT CONCEALED IN WALL OR OVERHEAD
CONDUIT CONCEALED BELOW FLOOR
CONDUIT TRANSITION UP
CONDUIT TRANSITION DOWN
CONDUIT STUBBED OUT
BRANCH CIRCUIT HOME RUN
CABLE TRAY (TYPE DENOTED)
CONDUIT SLEEVE (SIZE DENOTED)
WALL TELEPHONE OUTLET (TYPE DENOTED)48"***
TELEPHONE OUTLET (TYPE DENOTED)18" UNO
DATA OUTLET (INDICATED QTY CABLES)18" UNO
VOICE/DATA OUTLET (TYPE DENOTED)18" UNO
WIRELESS ACCESS POINT
TELEVISION OUTLET18" UNO
CEILING MOUNTED TELEVISION OUTLET
SPEAKER (WALL OR CEILING MOUNT)84"
HORN TYPE SPEAKER84"
SURFACE MOUNT SPEAKER SUSPENDED FROM CEILING
VOLUME CONTROL48"
INTERCOM STATION48"
ICM INTERCOM MASTER
KEYED NOTE (SEE SCHEDULE)E#
SPRINKLER FLOW SWITCH
SPRINKLER VALVE TAMPER SWITCH
FIRE ALARM HORN80"***
FIRE ALARM HORN WITH STROBE (CANDELAS)80"***
FIRE ALARM BELL80"***
FIRE ALARM BELL WITH STROBE (CANDELAS)80"***
FIRE ALARM CHIME80"***
FIRE ALARM CHIME WITH STROBE (CANDELAS)80"***
FIRE ALARM STROBE CANDELAS80"***
FIRE ALARM SPEAKER WITH STROBE (CANDELAS)80"***
FIRE ALARM REMOTE ANNUNCIATOR 72"**
FIRE ALARM CONTROL PANEL72"**
FIRE ALARM RELAY PANEL72"**
SMOKE DETECTOR (TYPE DENOTED)
SB = LOW FREQUENCY SOUNDER BASE
CO = COMBINATION SMOKE DETECTOR
AND CO DETECTOR
8"****
HEAT DETECTOR (TYPE AND TEMP DENOTED)
DUCT SMOKE DETECTOR (TYPE DENOTED)
LINEAR HEAT DETECTOR
REMOTE TEST/STATUS STATION48"
PULLSTATION48"***
DOOR HOLDER
DOOR CLOSER/HOLD OPEN
SMOKE DAMPER RELEASE
FIRE ALARM SHUT DOWN RELAY
ELECTRICAL SYMBOL LEGEND
ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED. DEVICES INDICATED AT 48" MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 48". DEVICES MAY BE INSTALLED IN CONCRETE MASONRY UNITS WITH THE TOP OF THE DEVICE AT 48".
* DISTANCE ABOVE DOOR FRAME ** DISTANCE TO TOP OF EQUIPMENT OR DEVICE *** DISTANCE TO HIGHEST OPERABLE POINT OF EQUIPMENT **** DISTANCE BELOW CEILING ***** DISTANCE TO BOTTOM OF DEVICE
1 LIGHTING CONTROL DENOTATION
SURFACE LIGHT (TYPE DENOTED)X
X RECESSED LIGHT (TYPE DENOTED)
X
X
X
WALL MOUNTED LIGHT (TYPE DENOTED)PER SCHED
WALL MOUNTED FLOOD LIGHT (TYPE DENOTED)PER SCHED
SITE POLE MOUNTED LIGHT (TYPE DENOTED)PER SCHED
SURFACE LIGHT (TYPE DENOTED)
SUSPENDED OR PENDANT LIGHT (TYPE DENOTED)
RECESSED LIGHT (TYPE DENOTED)
SITE BOLLARD LIGHT (TYPE DENOTED)XPER SCHED
PIV POST INDICATING VALVE
FIRE ALARM MICROPHONE INTERFACE72"**
FAMI
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT
SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR
CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER
CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT
SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL
(CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC
SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND
AIR CONDITIONING
HWP HYDRONIC WATER PUMP
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT
SWITCH
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFDS NON-FUSED SAFETY
DISCONNECT SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
(CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL
CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL
CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV UNIT VENTILATOR OR
ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
L L
ELECTRICAL ABBREVIATIONS LIST
ANGLE
@ AT
DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
1. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL
ELECTRICAL CODE - LATEST EDITION ADOPTED BY THE STATE,
AND THE AUTHORITY HAVING JURISDICTION. THE COMPLETE
INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADAAG
(AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES).
2. IT IS THE INTENT OF THESE DOCUMENTS TO COMPLY WITH THE
APPLICABLE CODES. WHERE DISCREPANCIES OCCUR, NOTIFY THE
ENGINEER/ARCHITECT IN WRITING FOR INTERPRETATION.
CORRECT ANY INSTALLATION THAT FAILS TO COMPLY WITH THE
CODES AND STANDARDS AT NO ADDITIONAL COST TO THE
OWNER.
3. CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY INCLUDING
ALL LABOR, MATERIALS, PERMITS, TAXES, FEES, INSPECTIONS,
HARDWARE, AND COST FOR INSTALLATION FOR A COMPLETE AND
OPERATIONAL SYSTEM.
4. ALL MATERIALS FURNISHED BY THE CONTRACTOR SHALL BE NEW,
COMPLETE WITH MANUFACTURER’S GUARANTEE OR WARRANTY
AND SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY (NRTL).
5. COORDINATE ELECTRICAL INSTALLATION WITH ALL TRADES PRIOR
TO INSTALLATION. IF ELECTRICAL WORK INSTALLED INTERFERES
WITH OTHER TRADES AFTER INSTALLATION, THE CONTRACTOR
SHALL MAKE ALL NECESSARY CHANGES TO CORRECT THE
CONDITION AT NO ADDITIONAL COST TO THE OWNER.
6. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE
APPROXIMATE. CONTRACTOR SHALL VERIFY ALL FURNITURE,
MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH
ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP
DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL
INSTALLATION THIS CONTRACTOR SHALL ADJUST CONNECTION
LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
7. ALL ELECTRICAL PANELS WITH ANY BRANCH CIRCUIT/LOAD
REVISIONS (DEMOLITION OR NEW WORK) SHALL HAVE A NEW
TYPED UPDATED CIRCUIT DIRECTORY CARD INSTALLED INSIDE
THE DOOR OF THE ELECTRICAL PANEL. THE CONTRACTOR SHALL
VERIFY THAT ALL UNUSED CIRCUIT BREAKERS ARE TURNED ‘OFF’
AND PROPERLY INDICATED AS ‘SPARE’ ON THE NEW CIRCUIT
DIRECTORY CARD.
8. NO ENERGIZED CONDUCTORS SHALL BE EXPOSED AT ANYTIME
EXCEPT WHEN THE IMMEDIATE AREA IS UNDER THE SUPERVISION
OF A QUALIFIED ELECTRICIAN.
9. WHERE CONDUIT IS SURFACE MOUNTED TO A WALL AND RUN
VERTICALLY DOWN TO A SWITCH/OUTLET BOX, UTILIZE 1-HOLE OR
2-HOLE CONDUIT STRAPS.
10. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN OF ALL
DEBRIS ON A DAILY BASIS. ALL NEW MATERIALS AWAITING
INSTALLATION SHALL BE KEPT IN AREAS DESIGNATED BY THE
OWNER.
11. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY FOR
THE PURPOSE OF DETERMINING IF THE WORK OF THE
CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION
SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS
TO CHECK THE QUALITY OR QUANTITY OF THE WORK, BUT
RATHER PERIODIC IN AN EFFORT TO GUARD THE OWNER AGAINST
DEFECTS OR DEFICIENCIES IN THE WORK OF THE CONTRACTOR.
12. THE INFORMATION CONTAINED ON THE ELECTRICAL DRAWINGS IS
IN ITSELF INCOMPLETE AND VOID UNLESS USED IN CONJUNCTION
WITH ALL OTHER DISCIPLINE DRAWINGS, THE SPECIFICATIONS,
TRADE PRACTICES, OR APPLICABLE STANDARDS, CODES, ETC.,
AND SHALL BE CONSIDERED THE CONTRACT DOCUMENTS AND
WITH ALL THEREIN BY REFERENCE, WHICH THE CONTRACTOR
CERTIFIES KNOWLEDGE OF BY SIGNING THE CONTRACT.
13. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY, UNRELIEVED
BY REVIEW OF SHOP DRAWINGS OR PERIODIC OBSERVATION OF
CONSTRUCTION, FOR COMPLIANCE WITH THE CONTRACT
DOCUMENTS, FOR DIMENSIONS TO BE CONFIRMED AND
CORRELATED ON THE JOB SITE AND BETWEEN INDIVIDUAL
DRAWINGS OR SETS OF DRAWINGS FOR FABRICATION
PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING
EXCAVATION, SHORING, SCAFFOLDING, BRACING, ERECTION,
FORM WORK, ETC.), FOR COORDINATION OF THE VARIOUS
TRADES, AND FOR SAFE CONDITIONS ON THE JOB SITE.
VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE CONTRACT
DOCUMENTS SHALL BE REPORTED TO THE ENGINEER AS SOON
AS THEY ARE FOUND. WORK SHALL NOT PROGRESS UNTIL
WRITTEN PERMISSION FROM THE ENGINEER IS OBTAINED.
ELECTRICAL GENERAL NOTES
1. LIGHT LINES INDICATE EXISTING WALLS AND EQUIPMENT
TO REMAIN. DASHED LINES INDICATE WALLS, EQUIPMENT,
AND ELECTRICAL ITEMS TO BE REMOVED.
2. COORDINATE PATCHING REQUIREMENTS FOR UNUSED
OPENINGS WITH THE CONSTRUCTION MANAGER.
3. FIRE ALARM - REMOVE EXISTING CEILING MOUNTED
DEVICES TO PERMIT REMOVAL OF CEILING. WALL
MOUNTED NOTIFICATION DEVICES SHALL BE SALVAGED
AND RETURNED TO OWNER. COORDINATE WORK WITH
PROJECT PHASING TO MAINTAIN FIRE ALARM SYSTEM
PROTECTION OF SPACES AT ALL TIMES.
4. ALL EXISTING FIRE ALARM DEVICES TO BE SALVAGED AND
RETURNED TO OWNER. COORDINATE DISPOSAL OF ALL
ITEMS NOT REQUESTED AS SALVAGE BY THE OWNER.
5. DRAWINGS DO NOT IDENTIFY ALL OUTLETS, SWITCHES,
CABLING, OR EQUIPMENT TO BE REMOVED. CONTRACTOR
SHALL BECOME FAMILIAR WITH THE SITE PRIOR TO
BIDDING AND INCLUDE LABOR AND MATERIAL NECESSARY
FOR REQUIRED DEMOLITION IN THEIR BID.
6. WIRING SHALL BE REMOVED BACK TO SERVING PANEL.
INSTALLATION OF NEW CONDUCTORS IN EXISTING
CONDUITS WILL BE PERMITTED AS DESCRIBED IN THE
DIVISION 26 SPECIFICATIONS.
7. CONTRACTOR TO REMOVE ELECTRICAL CONNECTION TO
HVAC AND PLUMPING EQUIPMENT THAT IS BEING
REMOVED. REFER TO DEMOLITION DRAWINGS FOR
LOCATION OF EQUIPMENT.
DEMOLITION GENERAL NOTES
SEAL
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O J E
C T
N U
M B
E R
F
IE
L D
B O
O K
W
E S
T O
W N
P K
W Y
S
U
IT
E
W E
S T
D E
S M
O
IN
E S
IA
.2
.8
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2022
F ir e
A la rm P h a s e
.0
W R
C D e c e n tr a liz a ti o n P h a s e
.2
/1
/2
:0
:0
A
M
A u to d e sk
D o c s:
IA
D A
S
W R
C P ro je c ts
/W e s tw o o d -M
E P
-R M a s te r.
rv t
E L E
C T
R
IC
A L
G E
N E
R A
L
IN
F O
R M
A T
IO
N
C D
K J B
R M
L
-0
-1
00-E000
Io w a D e p a rt m e n t o f
A d m in is tr a ti v e S e rv ic e s th
S t, W o o d w a rd
IA
DN UP
UP UP
UP
DN
DN
UPDN
DN DN
DN
UP
UP
DN
AD.01
AD.02
AD.02
AD.02AD.02
AD.02
AD.02
AD.02AD.02AD.02
AD.02
AD.02
AD.01
AD.02
AD.02
AD.02
N.C. N.C. N.C.
N.C.
AD.01
AD.01
N.C.
AD.02
AD.02
AD.02
AD.02
AD.01
AD.01
AD.01
AD.02
AD.02
AD.02
N.C.N.C.
AD.02
AD.01AD.02
AD.02
AD.02
AD.02
AD.02AD.02
AD.02AD.02AD.02AD.02AD.02AD.02
N.C.N.C.
N.C.
N.C. N.C.
N.C.N.C.
N.C.
N.C.
N.C.
N.C.
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF
DEMOLITION WORK. NOTIFY ARCHITECT IN WRITING OF
DISCREPANCIES BETWEEN WORK SHOWN IN THE DRAWINGS
AND FIELD CONDITIONS ENCOUNTERED.
2. TO PROTECT OWNER AND CONTRACTOR,
PHOTOGRAPHICALLY DOCUMENT EXISTING CONDITIONS TO
REMAIN, PRIOR TO START OF DEMOLITION AND
CONSTRUCTION ACTIVITIES. COPY ARCHITECT AND OWNER
ON PHOTOGRAPHIC DOCUMENTATION.
3. OPEN FLAME EQUIPMENT IS NOT PERMITTED FOR REMOVAL
OF EXISTING WORK WITHOUT SPECIFIC WRITTEN PERMISSION
FROM THE OWNER.
4. COORDINATE WITH OWNER ANY ITEMS TO BE SALVAGED.
5. OWNER WILL REMOVE ALL NON-FIXED FURNISHINGS AND
EQUIPMENT FROM THE CONSTRUCTION AREA PRIOR TO
START OF CONSTRUCTION UNLESS NOTED OTHERWISE.
6. MAINTAIN BUILDING IN A WEATHER-TIGHT CONDITION. DO NOT
PERFORM WORK ON EXTERIOR OPENINGS THAT CANNOT BE
COMPLETED OR MADE WEATHER-TIGHT WHEN INCLEMENT
WEATHER IS POSSIBLE.
7. COORDINATE WITH OTHER TRADES CUTTING AND PATCHING
REQUIRED FOR DEMOLITION OR NEW CONSTRUCTION.
8. ANY DEMOLITION OR REMOVAL INDICATED IS SHOWN IN
GENERAL TO PROVIDE THE EXTENT OF DEMOLITION AND IS
NOT TO BE CONSIDERED AS A RECORD DRAWING OF EXISTING
CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR IN
FIELD VERIFICATION AND COORDINATION WITH THE
ARCHITECT PRIOR TO COMMENCING WITH STATED WORK.
9. ALL CONSTRUCTION TO REMAIN WHICH IS AFFECTED BY
DEMOLITION SHALL BE PATCHED, BE PROPERLY ALIGNED AND
FINISHED SO AS TO LEAVE NO EVIDENCE OF PATCHING OR
REPAIR. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION,
MATERIALS, OR EQUIPMENT DAMAGED DURING DEMOLITION
TO LIKE NEW CONDITION.
10. THE CONTRACTOR IS TO RETURN SALVAGEABLE MATERIALS,
INCLUDING BUT NOT LIMITED TO DOORS, FRAMES,
HARDWARE, MARBLE, EQUIPMENT, AND LIGHTING FIXTURES
TO THE OWNER AND STOCKPILE THEM IN AN APPROVED
CONSTRUCTION AREA. DISPOSE OF THESE MATERIALS AFTER
OWNER'S REVIEW AND APPROVAL.
11. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL
FINISHES (TO REMAIN) IN THE PROJECT AREA. COORDINATE
WITH ARCHITECT AND OWNER PRIOR TO DEMOLITION.
12. CONTRACTOR SHALL ENSURE THAT DUST AND DEBRIS ARE
PREVENTED FROM ENTERING THE EXISTING HVAC SYSTEM
AND ADJOINING SPACES WITH TEMPORARY BARRIERS AS
REQUIRED PER THE BUILDING.
13. INDICATION OF NEW MATERIALS SHALL INFER ALL REMOVAL
OR DEMOLITION AND PATCHING REQUIRED OF EXISTING
MATERIALS AND SUBSTRATES FOR PROPER ALIGNMENT.
MATCH EXISTING FINISHES.
14. ALL NEW AND EXISTING PENETRATIONS IN EXISTING WALLS,
FLOORS AND CEILING DECKS SHALL RECEIVE UL AND FACILITY
APPROVED FIRE SEALANT MATERIALS TO MATCH RATING
REQUIREMENT OF AREA BEING PENETRATED.
ARCHITECTURAL DEMOLITION NOTES
EXISTING WALL PARTITIONS
EXISTING DOOR
DEMOLITION PLAN SYMBOLS LEGEND
REMOVE CEILING PANELS AND GRID FOR
INSTALL OF ABOVE CEILING UTILITIES.
COORDINATE WITH MEP DRAWINGS.
NO CEILING IN SPACEN.C.
CORRIDOR
TOILET
103 COUNSEL
WORKROOM
STORAGE
112 OFFICE
DAY ROOM
ACTIVITY
NOT USED
FOOD SERVING AREA
OFFICE
LOBBY
OFFICE
STORAGE
123A
MECHANICAL
COUNSEL
125 TOILET
TOILET
127 STORAGE
COUNSEL
129 TOILET
TOILET
131 DAY ROOM
OFFICE
TOILET
TOILET
102OFFICE
STAFF RESTROOM
MUD ROOM
A02.01
A02.01
A02.01
A02.01
A02.01 A02.01 A02.01 A02.01
A02.01 A02.01
A02.01
A02.01
A02.01
A02.01
A02.01
DAY ROOM
TOILET
TOILET
STORAGE
STORAGE
MECHANICAL
BREAKROOM
STORAGE
STORAGE
STORAGE
TOILET
JANITOR CLOSET
202A
TOILET
OFFICE
DAY ROOM
STORAGE
TOILET
ACTIVITY
OFFICE
STORAGE
MECHANICAL
STORAGE
OFFICE
STORAGE
STORAGE
TOILET
TOILET
STAFF TOILET
229A
TOILET
TOILET
STORAGE
DAY ROOM
A02.01
A02.01
A02.01
A02.01
A02.01
A02.01
A02.01
A02.01
A02.01 A02.01
A02.01
A02.01
A02.01 A02.01
CLASSROOM
B09
TOILET
B03
TOILET
B02
MECH
B06
STORAGE
B07
STORAGE
B08
DAY ROOM
B01
MECHANICAL
B09A
STORAGE
B10
ELECTRICAL ROOM
B35
ACTIVITY
B15
BEAUTY
B20
CLASS ROOM
B16
COOLER
B18
OFFICE
B19
ACTIVITY
B17
COMMON AREA
B13
STORAGE
B012
STORAGE
B21
STORAGE
B23
LOBBY
B24
ELEV. EQPT.
B25
MECHANICAL
B26A
TOILET
B27
TOILET
B28
OFFICE
B31
STORAGE
B32
STORAGE
B33
DAY ROOM
B34
STAFF RESTROOM
B30
SPRINKLER
B04
MECHANICAL
B12
MECHANICAL
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
309 STORAGE
STORAGE
MECHANICAL
STORAGE
STORAGE
A P
P R
O V
E D
B Y
D R
A W
N B
Y
IS
S
U E
D F
O R
IS
S
U E
D A
T E
P R
O J E
C T
N U
M B
E R
F
IE
L D
B O
O K
W
E S
T O
W N
P K
W Y
S
U
IT
E
W E
S T
D E
S M
O
IN
E S
IA
.2
.8
S
H
IV
E -H
A T
T E
R Y
.C O
M
BA D E
FC G
H
BA D E FC G H
Autodesk Revit 2022
KEY PLAN
F ir e
A la rm P h a s e
.0
W R
C D e c e n tr a liz a ti o n P h a s e
.2
/1
/2
:4
:5
A u to d e s k D o c s
/I A
D A
S
W R
C P ro je c ts
/W e s tw o o d -A
-R M a s te r.
rv t
W E
S T
W O
O D
D E
M O
F L
O O
R P
L A
N S
D
E M
O R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N S
C D
E E
M
Z M
S
-0
-1
01-AD01
Io w a D e p a rt m e n t o f
A d m in is tr a ti v e S e rv ic e s th
S t.
W o o d w a rd
IA
TRUE NORTH
NORTH
PLAN
TRUE NORTH
NORTH
PLAN
TRUE NORTH
NORTH
PLAN
TRUE NORTH
NORTH
PLAN
01/16" = 1'-0"D2
WESTWOOD BASEMENT DEMO RCP
24'
TRUE NORTH
NORTH
PLAN
01/16" = 1'-0"D4
WESTWOOD FIRST FLOOR DEMO RCP
24'TRUE NORTH
NORTH
PLAN
01/16" = 1'-0"D6
WESTWOOD SECOND FLOOR DEMO RCP
24'TRUE NORTH
NORTH
PLAN
01/16" = 1'-0"E6
WESTWOOD THIRD DEMO RCP
24'
TRUE NORTH
NORTH
PLAN
KEYNOTES
KEY NOTE
A02.01 REMOVE RADIATOR ENCLOSURE FRONT ACCESS
PANEL TO ENABLE DEMO OF MECHANICAL EQUIPMENT
PER MECHANICAL DEMO PLANS 01-MD100, 01-MD101,
01-MD102. ACCESS PANEL TO BE REINSTALLED WITH
T20 TORX SECURITY SCREWS.
AD.01 DEMO CEILING IN ROOM
AD.02 REMOVE CEILING PANELS AND GRID FOR INSTALL OF
ABOVE CEILING UTILITIES. COORDINATE WITH MEP
DRAWINGS.
01/16" = 1'-0"A4
WESTWOOD FIRST FLOOR PLAN DEMO
24'
01/16" = 1'-0"A6
WESTWOOD SECOND FLOOR PLAN DEMO
24'
01/16" = 1'-0"A2
WESTWOOD BASEMENT DEMO
24'
01/16" = 1'-0"B6
WESTWOOD THIRD FLOOR PLAN DEMO
24'
UP
UP
DN UP
UP UP
UP
DN
DN
UPDN
DN DN
DN
DN
FSTS
F S
F S
F S
F
F S
S
FA
S
FA
F S
S
FA
F S
S
FA
F S
F S
S
F S
S
FA
F S
S
FA
F S
F S
S
FA
S
FA
F S
F S
F S
F S
S
FA
S
FA
F F
F S
S
FA
F S
S
FA
F S
F S
S
FA
S
FA
F S
F S
F S
FS
TS
TS
F
F
F
FFS
TS
FS
TS
F
F S
F F
FACP
F
F S
S
F S S
FA
S
FA F
S
S
FA
S
FA
F S
F S
S
FA
S
FA
F S
F S
F S
F S
F S
F S
S
FA
F S
S
FA
S
FA
F S
S
FA
F S
F S
F S
FS
S
FA
F S
S
FA
F S
F S
F S
S
FA
F S
F S
S
FA
F S
F S
F S
F S F
S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S F F
F F
F S F
S
F S
S
FA
S
FA
F S
F S
S
FA
S
FA
F S
F S
F S
F S
F S
F S
F S
F S
S
FA
S
FA
F S
F F
FF
FS
F
F S
S
FA
S
FA
S
FA
S
FA
S
FA
F S
S
FA
F S
F S
F F
F
F
F S
F S
F S
DAY ROOM
B01
TOILET
B02
TOILET
B03
CORRIDOR
B05
MECH
B06
STORAGE
B07
STORAGE
B08
CLASSROOM
B09
MECHANICAL
B09A STORAGE
B10
STORAGE
B012
COMMON AREA
B13
STAIR
S2
ACTIVITY
B15
CLASS ROOM
B16
ACTIVITY
B17
COOLER
B18
OFFICE
B19
BEAUTY
B20
STORAGE
B21
STORAGE
B22
STORAGE
B23
LOBBY
B24
ELEV. EQPT.
B25
MECHANICAL
B26A
TOILET
B27
TOILET
B28
OFFICE
B31
STORAGE
B32
STORAGE
B33
DAY ROOM
B34
ELECTRICAL ROOM
B35
STORAGE
B11
ELEV.
CLASSROOM
B26
SPRINKLER
B04
MECHANICAL
B12
STAFF RESTROOM
B30
TOILET
B17A
STAIRS
S1
OFFICE
OFFICE
OFFICE
TOILET
TOILET
COUNSEL
CORRIDOR
TOILET
TOILET
COUNSEL
WORKROOM
STORAGE
112 OFFICE
DAY ROOM
FOOD SERVING AREA
LOBBY
OFFICE
STORAGE
123A
MECHANICAL
COUNSEL
TOILET
TOILET
COUNSEL
129 TOILET
TOILET
131 DAY ROOM
STORAGE
ACTIVITY
MUD ROOM
Elev.
A02.01
A02.02
A02.02
A02.02
CORRIDOR
WORK ROOM
136WORKROOM
STAIRS
S2
STAIRS
S1
TOILET
117A
STAIR
STAIR
DAY ROOM
OFFICE
TOILET
JANITOR CLOSET
202A
TOILET
STORAGE
TOILET
TOILET
STORAGE
STORAGE
STORAGE
BREAKROOM
DAY ROOM
OFFICE
STORAGE
OFFICE
STORAGE
232 TOILET
TOILET
DAY ROOM
STORAGE
TOILET
STAFF TOILET
229A
TOILET
229STORAGE
ACTIVITY
TOILET
STORAGE
STORAGE
MECHANICAL
STORAGE
MECHANICAL
ELEV.
A02.02
A02.02
A02.02A02.02
A02.02
A02.02
A02.02
WORKROOM
WORKROOM
STAIRS
S2
STAIRS
S1
STAIRS
STAIRS
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
MECHANICAL
STORAGE
STORAGE
STORAGE
MECHANICAL
A02.01
STAIRS
S2
ACTIVITY
B17
CLASS ROOM
B16
OFFICE
B19
COOLER
B18
BEAUTY
B20
ELEV.
LOBBY
B24
MECHANICAL
B26A
CLASSROOM
B26 DAY ROOM
B34
TOILET
B28
TOILET
B27
OFFICE
B31
STORAGE
B33
STORAGE
B32
ELEV. EQPT.
B25
STORAGE
B23
COMMON AREA
B13
STORAGE
B21
STORAGE
B012
STORAGE
B22
STORAGE
B11
STORAGE
B10
CLASSROOM
B09
MECHANICAL
B09A
STAIR
S2
ACTIVITY
B15
ELECTRICAL ROOM
B35TOILET
B03
TOILET
B02
DAY ROOM
B01
MECH
B06
STORAGE
B07
STORAGE
B08
OFFICE
OFFICE
OFFICE
TOILET
TOILET
COUNSEL
CORRIDOR
TOILET
TOILET
COUNSEL
WORKROOM
STORAGE
OFFICE
DAY ROOM
FOOD SERVING AREA
LOBBY
OFFICE
STORAGE
123A
MECHANICAL
COUNSEL
TOILET
TOILET
COUNSEL
TOILET
TOILET
131 DAY ROOM
STORAGE
ACTIVITY
MUD ROOM
Elev.
CORRIDOR
DAY ROOM
OFFICE
TOILET
JANITOR CLOSET
202A
TOILET
STORAGE
TOILET
TOILET
STORAGE
STORAGE
STORAGE
BREAKROOM
DAY ROOM
OFFICE
STORAGE
OFFICE
STORAGE
TOILET
TOILET
DAY ROOM
STORAGE
TOILET
STAFF TOILET
229A
TOILET
STORAGE
ACTIVITY
TOILET
STORAGE
STORAGE
MECHANICAL
STORAGE
MECHANICAL
ELEV.
GYPSUM BOARD CEILING/ SOFFIT
ACOUSTICAL CEILING PANEL SYSTEM
SURFACE LIGHT
SUSPENDED OR PENDANT LIGHT
RECESSED LIGHT
CEILING PLAN SYMBOLS LEGEND
1. NOTIFY ARCHITECT OF INADEQUATE CLEARANCES FOR
CEILING LAYOUT…