RFB925000-01 - DOC MPCF Blding 18 Roof Replacement - Drawings.pdf
PDF 7 MB Posted
- Attached to
- DOC MPCF Bldg 18 Roof Replacement
- Solicitation number
- RFB925000-01
- Issued by
- Henry County, Iowa
About this file
Project Summary
This is a construction drawings set for the Iowa Department of Administrative Services' roof replacement project at Building 18 of the Mount Pleasant Correctional Facility (MPCF) located at 1200 E Washington Street, Mount Pleasant, Iowa 52641. The project scope encompasses demolition and abatement of the existing roof system (Bid Package 01) and installation of new roofing, gutters, downspouts, and associated sheet metal work (Bid Package 02). The existing roof consists of 3-1/4" x 9" wood rafters spaced at approximately 32" on center with 1x4 nominal boards; the new construction will feature synthetic slate shingles, 1/2" plywood sheathing as required by manufacturer specifications, ice and water shield underlayment, new ridge vents, new open valley flashing, new gutters and 6" diameter corrugated round downspouts, and a snow retention system with approximately 12 pad-style snow guards per roofing square. The drawings, dated June 21, 2023, include a site access plan, abatement/demo plan, roof plan, exterior elevations, and detailed construction sections. Bidding documents were available beginning August 3, 2023, from Beeline and Blue (www.beelineandblue.com or 515-244-1611), with bids due on September 12, 2023, at 2:00 PM, followed by a public bid opening at 3:00 PM the same day.
The project involves significant abatement requirements due to asbestos-containing materials (ACM) present in the existing roof, gutters, downspouts, sealants, and step flashing. The abatement contractor must remove and properly dispose of ACM waste, including asbestos cement shingles, contaminated sealants, and lead-containing pipe penetration boots, with coordination required between the abatement and roofing contractors. Contractors must comply with OSHA construction standards for fall protection (29 CFR 1926.500(B)) and scaffolding provisions (29 CFR 1926.450(B)), and must avoid interference with the tunnel system located beneath surrounding sidewalks. All existing elements not scheduled for removal, including trees, sidewalks, buildings, and other site improvements, must be protected from damage. The drawings indicate that Bid Package 02 will be responsible for penetrations required for the new ridge vent, and downspout pathways are shown diagrammatically with contractors required to verify field conditions and optimize routing. Contractors must be registered with the Iowa Labor Commissioner and comply with all state and federal affirmative action and equal employment opportunity requirements.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9250.00 - DOC MPCF
BUILDING 18 ROOF REPLACEMENT
1200 E WASHINGTON
MOUNT PLEASANT, IOWA 52641
052.22 Activity ID: #925000
100% CONSTRUCTION DOCUMENTS
06.21.2023
Sheet List
Sheet Number Sheet Name
G0.01 ABBREVIATIONS, SYMBOLS, SHEET LIST, SITE ACCESS PLAN
AD1.00 ABATEMENT AND DEMO PLAN (TERRACON)
A1.00 ROOF PLAN - NEW
A2.00 EXTERIOR ELEVATIONS
A4.00 DETAILS
A4.01 DETAILS
A5.00 PHOTOS OF EXISTING
AWOI
PR
OFESSIONAL ARCH
I T
EC
T
LI
CE
NS
ED
I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed architect under the laws of the State of Iowa.
(Signature)
(Printed or Type Name) (License Num.)
My license renewal date is
Sheets covered by this seal
Melinda Aust
05898
Melinda Aust 05898
June 30, 2024
G0.01, A1.00, A2.00, A4.00, A4.01, A5.00
SHEET AD1.00 COVERED BY:
1t
ROOM NAME
150 SF
1t
GLAZING / WINDOW IDENTIFICATION
ROOM IDENTIFICATION
DETAIL / ENLARGED PLAN REFERENCE
SPOT ELEVATION
VERTICAL ELEVATION
FLOOR F1
0' - 0"
D2 A-512
SIM
1t
1t
A1 VIEW NAME
SCALE:1/8" = 1'-0", REF: A / A101
MILLWORK / FURNITURE / EQUIPMENT IDENTIFICATION
WALL TYPE IDENTIFICATION
SECTION REFERENCE
DRAWING IDENTIFICATION
STRUCTURAL GRID
1t1t
A-303
SIM
PLAN
NORTH
INTERIOR ELEVATION REFERENCE
BUILDING ELEVATION REFERENCE
DOOR / SIGNAGE IDENTIFICATION
PLAN NORTH REFERENCE
DRAWING REVISION
A2-02
1 SIM
A2-02
SIM
DENOTES REFERENCE
DENOTES ELEVATION
DETAIL NUMBER
SHEET NUMBER
ROOM NAME
ROOM NUMBER
AREA
GLAZING / WINDOW TYPE
REFERENCE
A
B
GRID REFERENCE
DETAIL NUMBER
DRAWING TITLE
DRAWING SCALE AND
REFERENCING DETAIL
DARKENED AREA
DENOTES SECTION
DRAWN
DETAIL NUMBER
SHEET NUMBER
WALL TYPE
REFERENCE
TYPE REFERENCE
REVISION SEQUENCE NUMBER
(REFER TO REVISION TABLE
ON SHEET TO SEE
CORRESPONDING ISSUANCE)
DASHED LINE INDICATES
TRUE NORTH
DOOR NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUBMER
TOS EL 0'-0"
DENOTES ELEVATION
DENOTES OBJECT
REFERENCED
KEYNOTE IDENTIFICATION
1?04 20 00.A1
SHEET KEYNOTE - REFER
TO LEGEND ON SHEET
REFERENCE KEYNOTE -
REFER TO LEGEND ON SHEET
AND ASSOCIATED SPEC
SECTION
ROOM FINISH IDENTIFICATION FLOOR PLAN SYMBOLS
ROOM NAME
F B W C
ROOM NAME
ROOM NUMBER
FINISHES: FLOOR,
BASE, WALL, CELING
1t
CPT-1
CG
A (101) SIGN TYPE AND
NUMBER
CPT-1
CT-1
FLOOR FINISH
FLOOR FINISH
TRANSITION
CORNER GUARD
ALUMINUM
BATT INSULATION
BRICK & CLAY MASONRY
CERAMIC TILE
CONCRETE UNIT MASONRY
COMPACTED OR ENGINEERED FILL
CONCRETE
CONTINUOUS BLOCKING
DISCONTINUOUS BLOCKING
EARTH
GLAZING
GYPSUM WALL BOARD
RIGID INSULATION
SAND
SHEATHING
SPRAY INSULATION
WOOD - FINISH GRADE
STEEL
SECURETY FENCE
LINE LEGEND
LIGHTNING LN
HO
SP
IT
AL
A
VE
HO
SP
IT
AL
A
VE
EXISTING SHED
EXISTING SECURITY GATE
-DO NOT BLOCK
BLDG
CONSTRUCTION FENCE
CONTRACTOR PARKING +
PROJECT STAGING
CONSTRUCTION ROUTE
CONSTRUCTION ROUTE
BLDG
DUMPSTER LOCATION
IS NOT TO BE ON
GRASS
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000 MA Architecture No.:
Date:
www.kpff.com Ph. 515 279 3900 Des Moines, Iowa 50309 604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
6/2 1/2
3 2
:58 :09
P M
Au tod es k D oc s:/
/05 2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T/
2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T_
R2 2.r vt
.0
-D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
G0.01
ABBREVIATIONS, SYMBOLS, SHEET LIST,
SITE ACCESS PLAN
052.22
06.21.2023
ABBREVIATIONS
—— A ——
@ AT
A/V AUDIO-VISUAL
ABV ABOVE
ACC ACCESSIBLE
ACS DR ACCESS DOOR
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJUSTABLE
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
AL ALUMINUM
ALT ALTERNATE
ALUM ALUMINUM
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATELY
ARCH ARCHITECT
AWP ACOUSTICAL WALL PANEL
—— B ——
BC BY CONTRACTOR
BCKR BACKER
BCS BABY CHANGING STATION
BD BOARD
BLDG BUILDING
BLKHD BULKHEAD
BLW BELOW
BM BENCHMARK
BO BOTTOM OF
BOS BOTTOM OF STRUCTURE
BOT BOTTOM
BS BOTH SIDES
BTW BETWEEN
—— C ——
CAB CABINET
CBB CEMENTITIOUS BACKER
BOARD
CFOI CONTRACTOR FURNISHED,
OWNER INSTALLED
CG CORNER GUARD
CH COAT HOOK
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTERTOP
COL COLUMN
CONC CONCRETE
CONT CONTINUE (CONTINUOUS)
CONTR CONTRACTOR
COORD COORDINATE
COV COVER
CR CARD READER
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
CW CURTAIN WALL
—— D ——
DBL DOUBLE
DC DIMMER CONTORL
DEMO DEMOLITION (DEMOLISH)
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM(S) DIMENSION(S)
DO DOOR OPENING
DPTN DEMOUNTABLE PARTITION
DR DOOR
DS DOWNSPOUT
DSPL DISPOSAL
DT DRAIN TILE
DV DATA / VOICE OUTLET
DW DISHWASHER
DWG(S) DRAWING(S)
DWR DRAWER
—— E ——
E ELECTRICAL OUTLET
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (ELECTRICAL)
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EPS EXPANDED POLYSTYRENE
BOARD
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ETC ET CETERA
EW EACH WAY
EWS EYE WASH STATION
EXCL EXCLUDE (EXCLUDING)
EXP EXPANSION
EXST EXISTING
EXT EXTERIOR
—— F ——
TYPICAL SYMBOLS
MATERIAL KEY
PROJECT LOCATION
ABBREVIATIONS
F FEMALE
FA FIRE ALARM HORN / STROBE
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAB FABRIC
FACP FIRE ALARM CONTROL PNL
FAS FIRE ALARM PULL STATION
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FIN FINISH
FIXT FIXTURE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLOOR MOUNT
FLR FLOOR
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOW FACE OF WALL
FR FRAME(D)
FR GL FRITTED GLASS
FRP FIBER-REINFORCED PLASTIC
FRZ FREEZER
FT FOOT (FEET)
FT GL FULLY TEMPERED GLASS
FTG FOOTING
FURN FURNITURE
FUT FUTURE
FWRK FORMWORK
—— G ——
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS-FIBER REINFORCED
CONCRETE
GL GLASS
GLZ GLAZING
GRAN GRANITE
GRID GRIDLINE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GYP GYPSUM
—— H ——
HB HOSE BIB
HC HANDICAP
HD HAND DRYER
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HPC HIGH PERFORMANCE
COATING
HS HAND SINK
HT HEIGHT
HVAC HEATING, VENTILATING, AND
AIR CONDITIONING
—— I ——
IIC IMPACT ISOLATION CLASS
ILLUM ILLUMINATION
INCL INCLUDE (INCLUDING)
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
IT(S) INFORMATION TECHNOLOGY
(SERVICES)
—— J ——
JAN JANITOR
JT JOINT
—— K ——
KB KNOX BOX
KPT KICKPLATE
—— L ——
LAM LAMINATE (LAMINATED)
LAV LAVATORY
LD LINEAR DIFFUSER
LH LEFT HAND
LIN LINEAR
LINO LINOLEUM
LKR LOCKER
LNDSCP LANDSCAPE
LOC LOCATION
LT LIGHT
LTD LIMITED
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LYR LAYER
—— M ——
M MOTION SENSOR
MAINT MAINTENANCE
MATL MATERIAL
ABBREVIATIONS
MAX MAXIMUM
MBH MOP / BROOM HOLDER
MECH MECHANICAL
MEL MELAMINE
MEMB MEMBRANE
MF MILL FINISH
MFD MANUFACTURED
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLWK MILLWORK
MR MOISTURE RESISTANT
MT MOUNT
MTD MOUNTED
MTL METAL
MULL MULLION
MULT MULTIPLE
MW MICROWAVE
—— N ——
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NORM NORMAL
NRC NOISE REDUCTION COEFF.
NTS NOT TO SCALE
—— O ——
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORIG ORIGINAL
ORN ORNAMENTAL
OVFL OVERFLOW
—— P ——
PAR PARALLEL
PART PARTIAL
PAT PATTERN
PB PUSH BUTTON
PBD PARTICLEBOARD
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
POL POLISHED
PORC PORCELAIN
PREFAB PREFABRICATE
PREFIN PREFINISHED
PREFMD PREFORMED
PRELIM PRELIMINARY
PS PROJECTOR SCREEN CTRL
PT POST-TENSIONED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PTR PAPER TOWEL RECEPTACLE
PV PHOTOVOLTAIC
—— Q ——
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
QTZ QUARTZ
—— R ——
R RADIUS
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE
RB HK ROBE HOOK
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFRIGERATOR
REINF REINFORCE(D)
REM REMAINDER
REP REPAIR
REPL REPLACE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RFG ROOFING
RH RIGHT HAND
RM ROOM
RND ROUND
RO ROUGH OPENING
RTF RUBBER TILE FLOORING
RTG RATING (RATED)
RTU ROOFTOP UNIT
RVL REVEAL
—— S ——
S SWITCH
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
ABBREVIATIONS
SC SEALED CONCRETE
SCD SEAT COVER DISPENSER
SCHED SCHEDULE
SCRN SCREEN
SD SOAP DISPENSER
SD SMOKE DETECTOR
SECT SECTION
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHLF SHELF
SHR SHOWER
SHR HD SHOWERHEAD
SHT SHEET
SHV SHELVING
SIM SIMILAR
SLNT SEALANT
SLV SLEEVE
SN SANITARY NAPKIN DISPOSAL
SNK SINK
SNSR SENSOR
SP STANDPIPE
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION
CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUPT SUPPORT
SURF SURFACE
SURR SURROUND
SURV SURVEY
SUSP SUSPEND (SUSPENDED)
SYMM SYMMETRICAL
SYNTH SYNTHETIC
SYS SYSTEM
—— T ——
T THERMOSTAT
T&G TONGUE AND GROOVE
TB TOWEL BAR
TC TERRACOTTA
TD TRENCH DRAIN
TEMP TEMPORARY
TERM TERMINATION
THK THICKNESS
THRES THRESHOLD
TKSF TACK-SURFACE /
TACK-BOARD
TO TOP OF
TOS TOP OF SLAB
TOW TOP OF WALL
TRTD TREATED
TT TOILET TISSUE DISPENSER
TV TELEVISION
TYP TYPICAL
TZ TERRAZZO
—— U ——
UNO UNLESS NOTED OTHERWISE
UR URINAL
URS URINAL SCREEN
—— V ——
VAR VARIES
VB VINYL BASE
VEH VEHICLE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VN VENDING MACHINE
VNR VENEER
VOC VOLATILE ORGANIC
COMPOUND
—— W ——
W/ WITH
W/O WITHOUT
WB WOOD BASE
WBL WOOD BLOCKING
WC WATER CLOSET
WCO WALL CLEANOUT
WD WOOD
WH WATER HEATER
WLD WELDED
WO WINDOW OPENING
WT WEIGHT
WW WALL TO WALL
—— X ——
XPS EXTRUDED POLYSTYRENE
BOARD
—— Y ——
YCO YARD CLEANOUT
SITE ACCESS GENERAL NOTES:
1. MAIN PROJECT IS LOCATED OUTSIDE THE FACILITY'S SECURITY FENCE. NORTH PROJECT BOUNDARY IS ADJACENT TO A SECURE FENCE.
NORTH FACE OF BUILDING ABUTS SECURITY FENCE, NO CIRCULATION BETWEEN BUILDING AND FENCE ALLOWED AT THIS AREA
2. COORDINATE WITH OWNER LOCATIONS FOR CONSTRUCTION FENCE GATE, SCAFFOLDING, DUMPSTER, NEW MATERIAL PALETTES, AND PARKING.
3. PATCH WITH SOD ANY LAWN THAT IS DISTURBED DURING CONSTRUCTION.
4. DO NOT STORE MATERIAL UNDER THE DRIPLINE OF TREES.
5. PROTECT EXISTING ELEMENTS IDENTIFIED AND THOSE NOT DURING CONSTRUCTION INCLUDING ALL TREES AND SIDEWALKS.
SCALE: 1" = 60'-0"
SITE ACCESS PLAN
MARK DESCRIPTION DATE
1 2 3 4 5 6 7 8 109
9' - 0" 22' - 5" 35' - 2" 13' - 5 1/2" 29' - 5" 13' - 5 1/2" 35' - 2" 22' - 5" 9' - 0"
189' - 6"
A
Aa
B
C
D
Dd
2'
/2
3'
2"
0"
1/
2" 3'
1/ 2"
7"
1' -0
7"
1'
-0
7" / 1'-0"
7" / 1'-0" 7" / 1'-0"
7" / 1'-0" 7" / 1'-0"
7"
1' -0
7"
1'
-0
9" / 1'-0"9" / 1'-0"
7"
1' -0
7"
1'
-0
7" / 1'-0"
7" / 1'-0" 7" / 1'-0"
7" / 1'-0" 7" / 1'-0"
[No Slope] [No Slope]
A01 08 A01 08
A01 01
A01 01
A01 01
A01 01
A01 01A01 01A01 01A01 01A01 02 A01 02 A01 02 A01 02
A01 02
A01 02
A01 02
A01 02
A01 01
A01 02
A01 05
A01 06 A01 06
A01 07 A01 07
A01 07
[No Slope]
A01 12
/2
A01 13 A01 13 A01 13 A01 13
A01 13
A01 13
A01 13 A01 13 A01 13 A01 13 A01 13
A01 04
A01 04
A01 10
A01 11
A01 11
A01 11
A01 11 A01 04
A01 04
A01 10
A01 11
A01 11
A01 11
A01 11
A01 14 A01 14
A01 14 A01 14
A01 14 A01 14 A01 14 A01 14
A01 14 A01 14
A01 14 A01 14
A01 15
A01 15
A01 05
A01 15 A01 05
A01 15
A01 15
A01 15
A01 15
A01 15
A01 15
A01 04
A01 04
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
Revisions
925000 TERRACON No.:
Date:
319-366-8321
CEDAR RAPIDS, IOWA 52404
2640 12TH STREET SW
ERIC W. HARRIS (NO. 22-8944)
ABATEMENT PROJECT DESIGNER
TERRACON CONSULTANTS INC.
Activity ID:
.0
- D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
AD1.00
ABATEMENT DEMO PLAN
06237024
6.21.2023
1/8" = 1'-0"1 ABATEMENT DEMO PLAN
NUMBER KEYNOTE - DEMO
A01 01 EXISTING GUTTERS; 7" WIDE BY 4.5" DEEP TO BE REMOVED
A01 02 EXISTING SNOW APRON; COPPER; COPPER SHEETING TO BE REMOVED
A01 04 EXISTING FLASHING AT VALLEY; COPPER TO BE REMOVED
A01 05 EXISTING FLASHING, GALVANIZED STEEL TO REMAIN
A01 06 EXISTING STONE CAP - TO REMAIN, NO WORK
A01 07 EXISTING MEMBRANE ROOF; EPDM RUBBER; 60 MIL - TO REMAIN, NO WORK
A01 08 EXISTING ROOF ACCESS; COPPER CLADDING - TO REMAIN, NO WORK
A01 10 EXISTING VENT, COPPER - REMOVE, SCRAPE ACM, SAVE FOR OWNER
A01 11 EXISTING VENTILATION PIPE - LEADED BOOTS TO BE REMOVED
A01 12 EXISTING ELEVATOR OVERRUN, MEMBRANE ROOF, EPDM RUBBER - TO
REMAIN, NO WORK
MARK DESCRIPTION DATE
DEMO GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS NOTED. DO NOT SCALE THE DRAWINGS. ANY ERRORS
2. EXISTING ROOFING MATERIALS AND SEALANTS CONTAIN ASBESTOS. DEMOLITION OF THE EXISTING ROOF WILL BE THE RESPONSIBILITY OF THE ABATEMENT CONTRACTOR. THE ROOFING CONTRACTOR SHALL COORDINATE SCHEDULE WITH THE ABATEMENT CONTRACTOR
3. THE EXISTING ROOF CONSISTS PRIMARILY OF 3-1/4 ” X 9” WOOD RAFTERS SPACED AT APPROXIMATELY 32 ” O.C. WITH 1X4 NOMINAL
BOARDS SPANNING BETWEEN THEM.
4. MUST FIELD VERIFY ALL DIMENSIONS.
A01 13 EXISTING DOWNSPOUT TO BE REMOVED
A01 14 EXISTING 1"X8" FASCIA BOARD AND GABLE CAP TO BE REMOVED
OR OMISSIONS SHALL BE REPORTED TO MA ARCHITECTURE AND TERRACON WITHOUT DELAY.
LEGEND
ABATEMENT GENERAL NOTES
1. CONTRACTORS WILL BE RESPONSIBLE FOR INSTALLING AND UTILIZING FALL PROTECTION AS REQUIRED BY THE OSHA CONSTRUCTION STANDARD (29 CFR 1926.500(B).
2. WHERE SCAFFOLDING IS PROVIDED, ENSURE THAT ALL PROVISIONS OF OSHA CONSTRUCTION STANDARDS REGARDING SCAFFOLDING ARE MET (29 CFR 1926.450(B). PROTECT SCAFFOLDING
FROM ACM CONTAMINATION.
3. A TUNNEL SYSTEM IS PRESENT BELOW THE SIDEWALKS SURROUNDING THE BUILDING(S). MACHINERY SHALL AVOID THE TUNNEL SYSTEMS; NO PARKING/STAGING OF EQUIPMENT/SUPPLIES, DUMPSTER, OR DEBRIS ON THE TUNNEL SYSTEMS.
4. ADJACENT IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO BUILDINGS, PAVEMENT, STREETS, SIDEWALKS, CURBS, DRIVEWAYS, ELECTRICAL POLES AND LINES, DRAINAGE PIPES AND STRUCTURES, LAWNS, TREES, HANDHOLDS, SIGNS, ETC., TO REMAIN SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR.
5. ADDITIONAL INFORMATION REGARDING ASBESTOS CONTAINING MATERIALS (ACMS) IS INCLUDED IN SECTION 00 31 26 - EXISTING HAZARDOUS MATERIAL INFORMATION.
6. PLACEMENT OF THE ASBESTOS WASTE DUMPSTER SHALL BE COORDINATED WITH THE MPCF/CONSTRUCTION MANAGER.
7. COORDINATION WITH OTHER TRADES WILL BE REQUIRED, ESPECIALLY FOR THE MAIN ROOF FIELD AREA REMOVALS.
8. THE ASBESTOS CEMENT (A/C) SHINGLES SHALL BE CAREFULLY REMOVED AND BREAKAGE SHALL BE LIMITED. ALL ACM WASTE REMOVED FROM THE ROOF SHALL NOT BE DROPPED OR THROWN TO THE GROUND. ALL ACMS SHALL BE LOWERED TO THE GROUND IN ACCORDANCE WITH 1926.110(G)(8)(II)(E). ACMS SHALL NOT BE CRUMBLED, PULVERIZED OR REDUCED TO
POWDER.
9. THE APPROXIMATELY 35-INCH BY 35 INCH ROOF VENTS (01 10) SHALL BE REMOVED, ALL ACMS SHALL BE SCRAPED FROM THE VENTS/BASE AND THE VENT SHALL BE RETURNED TO THE
OWNER FOR REINSTALLATION. USE CAUTION WITH THE SOUTHERN VENT, AS IT IS DAMAGED.
10.PIPE PENETRATION BOOTS ARE LEAD. THE CONTRACTOR SHALL REMOVE HANDLE, AND DISPOSE OF THE LEAD BOOTS IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS. NOT ALL
PENETRATIONS MAY BE SHOWN ON THE DRAWINGS.
11.GUTTERS, INCLUDING STRAPPING, SHALL BE REMOVED BY THE ABATEMENT CONTRACTOR. SOME GUTTERS CONTAIN ASBESTOS ROOFING TILES/DEBRIS. RECYCLE THE GUTTERS AS
APPROPRIATE AND FOLLOWING ANY REQUIRED ACM CLEANING.
12.DOWNSPOUTS (LESS STAIR TOWERS) SHALL BE REMOVED BY THE ABATEMENT CONTRACTOR. SOME SECTIONS MAY CONTAIN ACM SEALANTS; SEAMS ARE SUSPECTED TO CONTAIN LEAD.
RECYCLE DOWNSPOUTS TO THE EXTENT PRACTICABLE. DOWNSPOUTS SHALL BE REMOVED TO THE IN-GROUND RISER COUPLING.
13.ALL STEP FLASHING SHALL BE CUT FLUSH WITH THE MORTAR JOINT AND SHALL BE TREATED AS ACM WASTE. THE ABATEMENT CONTRACTOR SHALL ALSO SCRAPE ACM SEALANT FROM
THE BRICK/MORTAR AT STEP FLASHING AREAS.
14.THE SNOW APRON, VALLEY FLASHING, AND THE GABLE CAP HAVE ACM ON THE SEAMS. THE SEAMS CAN LIKELY BE CUT WITHOUT DISTURBANCE; RECYCLE UNCONTAMINATED PORTIONS.
15.THE ATTIC SPACE SHALL BE PROTECTED TO THE EXTENT NECESSARY TO PREVENT ACMS FROM ENTERING THE BUILDING. THE ATTIC SPACE SHALL BE INSPECTED AND ANY DEBRIS SHALL BE REMEDIATED BY THE ABATEMENT CONTRACTOR. PLEASE NOTE THAT BAT GUANO AND RODENT DROPPINGS ARE PRESENT IN THE ATTIC SPACE - USE CAUTION.
APPROXIMATE LOCATION OF ASBESTOS CONTAINING
SEALANT/TAR TO BE ABATED
APPROXIMATE LOCATION OF ASBESTOS
CEMENT (A/C) SHINGLE, WITH ASBESTOS
FELT PAPER TO BE ABATED
A01 15 EXISTING STEP FLASHING TO BE REMOVED
5. BID PACKAGE #2 WILL BE RESPONSIBLE FOR THE PENETRATIONS REQUIRED FOR THE NEW RIDGE VENT.
1 2 3 4 5 6 7 8 109
A
Aa
B
C
D
Dd
9' - 0" 22' - 5" 35' - 2" 13' - 5 1/2" 29' - 5" 13' - 5 1/2" 35' - 2" 22' - 5" 9' - 0"
189' - 6"
2'
/2
3'
2"
0"
1/
2" 3'
1/ 2"
6"
1' -0
6"
1'
-0
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6"
1' -0
6"
1'
-0
6"
1' -0
6"
1'
-0
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
[No Slope][No Slope] [No Slope]
02 01
02 01 02 02
02 01
02 02
02 03
02 07
02 07
02 05
02 04
02 06
02 01
02 02
02 01
02 02
02 03
02 07
02 07
02 05
02 04
02 06
02 03
02 03
02 01
02 02
02 01
02 02
02 06 02 06
02 05
/2
A1 A4.00
A5 A4.00
A9 A4.00
02 08
FIELD VERIFY
FIELD VERIFY
FI
EL
D
VE
RI
FY
FI
EL
D
VE
RI
FY
FI
EL
D
VE
RI
FY
FI
EL
D
VE
RI
FY
FI
EL
D
VE
RI
FY
FI
EL
D
VE
RI
FY
FIELD VERIFY
FIELD VERIFY
02 01
02 01
02 01
02 02
02 02
02 06
02 06
02 06
02 07
02 09
02 09
02 09
02 09 02 09 02 09
02 09
A4.01 A4
02 10
02 10
02 1002 10
02 10
02 10 02 10
02 10
02 1002 10
A4.01 A1
TYP.
TYP.
TYP.
A4.01 E1
02 02
02 02
02 01
02 02
02 01
02 02
F5 A4.00 A4.00F9
FIELD VERIFY
FIELD VERIFY
02 11
TYP. AT ALL
ROOF
PENETRATIONS
02 11
02 11
02 11
02 11
02 11
02 1102 11
A4.01E6
E10 A4.01
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000 MA Architecture No.:
Date:
www.kpff.com Ph. 515 279 3900 Des Moines, Iowa 50309 604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
6/2 1/2
3 2
:57 :29
P M
Au tod es k D oc s:/
/05 2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T/
2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T_
R2 2.r vt
.0
-D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
A1.00
ROOF PLAN - NEW
052.22
06.21.2023
1/8" = 1'-0"1 ROOF PLAN - NEW
NEW CONSTRUCTION GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS NOTED. DO NOT SCALE THE DRAWINGS. ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO MA ARCHITECTURE WITHOUT DELAY.
2. CONTRACTOR TO VERIFIY ALL EXISTING SLOPES PRIOR TO INSTALLATION OF NEW ROOFING.
3. THE EXISTING ROOF CONSISTS PRIMARILY OF 3-1/4” X 9” WOOD RAFTERS SPACED AT APPROXIMATELY 32” O.C. WITH 1X4 NOMINAL BOARDS SPANNING BETWEEN THEM. THE EXISTING ROOF STRUCTURE SHALL BE FIELD VERIFIED AT THE TIME OF CONSTRUCTION FOR ANY EVIDENCE OF ROT OR DETERIORATION. IF ROT OR DETERIORATION IS DISCOVERED THE SECTION OF RAFTER SHALL BE REINFORCED OR REPAIRED IN KIND.
4. INSTALL NEW SNOW RETENTION SYSTEM WITH PAD-STYLE SNOW GUARDS, APPROXIMATELY 12 INSTALLED PER ROOFING SQUARE. LAYOUT TO BE DETERMINED BY MANUFACTURER.
NUMBER KEYNOTE - NEW CONSTRUCTION
02 01 INSTALL NEW ROOF SHINGLES, 1/2" PLYWOOD SHEATHING (AS REQ'D BY MANUF.) AND UNDERLAYMENT 02 02 INSPECT ALL SHEATHING WHEN EXPOSED. REPAIR DAMAGED OR ROTTED WITH NEW TO MATCH EXISTING. REFER TO
A1/A4.00- TYPICAL AT ALL GUTTER LOCATIONS (REFER TO KEYNOTE 02 09)
02 03 EXISTING EPDM ROOF TO REMAIN - NO WORK
02 04 RE-INSTALL SALVAGED COPPER VENTILATION HOOD- SEE DETAIL D12 ON SHEET A4.00
02 05 NEW RIDGE VENT
02 06 NEW FLASHING AT EXISTING MASONRY WALLS
02 07 NEW OPEN VALLEY FLASHING
02 08 NEW SHINGLED CRICKET
02 09 NEW GUTTER LOCATION
02 10 NEW DOWNSPOUT LOCATION- SEE EXTERIOR ELEVATIONS
02 11 INSTALL NEW SNOW RETENTION SYSTEM
Level 1 0' - 0"
Level 2 9' - 0"
Level 3 13' - 0"
ROOF 2
34' - 0"
ROOF 1
31' - 6"
ROOF 3
43' - 0"
NE
W
D
OW
NS
PO
UT
-9
W
NE
W
D
OW
NS
PO
UT
-8
W
NE
W
D
OW
NS
PO
UT
-7
W
NE
W
D
OW
NS
PO
UT
-4
W
NE
W
D
OW
NS
PO
UT
-3
W
NE
W
D
OW
NS
PO
UT
-2
W
23456789
A1 A4.00
A9 A4.00
A4.00 E1
9'
0" 4'
0"
2'
6" 9'
0"
GENERAL NOTE: ALL DOWNSPOUTS (DS) TO BE 6" IN DIAMETER AND TO BE
CORRUGATED ROUND IN SHAPE. SEE SPECIFICATION FOR INSTALLATION
REQUIREMENTS. DS PATHWAYS SHOWN AS DIAGRAM- CONTRACTOR TO VERIFY
FIELD CONDITIONS AND PROVIDE BEST/MOST SIMPLE PATHWAY.
EXISTING SPLASH
GUARD TO REMAIN.
EXISTING SPLASH
GUARD TO REMAIN.
EXISTING SPLASH
GUARD TO REMAIN.
TIE NEW DS INTO
EXISTING DRAIN
TILE TO REMAIN-
THIS LOCATION.
TIE NEW DS INTO EXISTING
ABOVE GRAD DRAIN TILE TO
REMAIN- THIS LOCATION.
Level 1 0' - 0"
Level 2 9' - 0"
Level 3 13' - 0"
ROOF 2
34' - 0"
ROOF 1
31' - 6"
ROOF 3
43' - 0"
NE
W
D
OW
NS
PO
UT
-2
E
NE
W
D
OW
NS
PO
UT
-3
E
NE
W
D
OW
NS
PO
UT
-4
E
NE
W
D
OW
NS
PO
UT
-7
E
NE
W
D
OW
NS
PO
UT
-8
E
NE
W
D
OW
NS
PO
UT
-9
E
2 3 4 5 6 7 8 9
A1 A4.00
A9 A4.00
9'
0" 2'
6"
4'
0" 9'
0"
GENERAL NOTE: ALL DOWNSPOUTS (DS) TO BE 6" IN DIAMETER AND TO BE
CORRUGATED ROUND IN SHAPE. SEE SPECIFICATION FOR INSTALLATION
REQUIREMENTS. DS PATHWAYS SHOWN AS DIAGRAM- CONTRACTOR TO VERIFY
FIELD CONDITIONS AND PROVIDE BEST/MOST SIMPLE PATHWAY.
TIE NEW DS INTO
EXISTING DRAIN TILE
TO REMAIN- THESE
LOCATIONS.
EXISTING SPLASH
GUARD TO REMAIN.
EXISTING SPLASH
GUARD TO REMAIN.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000 MA Architecture No.:
Date:
www.kpff.com Ph. 515 279 3900 Des Moines, Iowa 50309 604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
6/2 1/2
3 3
:11 :30
P M
Au tod es k D oc s:/
/05 2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T/
2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T_
R2 2.r vt
.0
-D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
A2.00
EXTERIOR ELEVATIONS
052.22
06.21.2023
1/8" = 1'-0"1 WEST ELEVATION - DIAGRAM
1/8" = 1'-0"2 EAST ELEVATION - DIAGRAM
SYNTHETIC SLATE SHINGLE
EXISTING MASONRY WALL TO REMAIN. PROTECT
DURING CONSTRUCTION. REPORT ANY DAMAGE
IMMEDIATELY TO OWNER.
EXISTING PAINTED SOFFIT AND MOLDINGS.
ICE AND WATER SHIELD
UNDERLAYMENT
UNDERLAYMENT
EAVE METAL FASCIA
NEW GUTTER
AT LOCATION WHERE SNOW
APRON WAS DEMOLISHED
PROVIDE NEW BLOCKING AND
SHEATHING-THICKNESS TO
MATCH EXISTING SHEATHING
EXISTING WD FASCIA- PAINT AFTER
DEMOLITION PRIOR TO NEW INSTALLATION
COLOR TO MATCH EXISTING
2'-0 " F
IE
LD V
ERIFY
0' - 6"
ROOF HUNG GUTTER:
CONFIRM GUTTER SIZING
BASED ON 100 YEAR IOWA
RAINFALL. SLOPE GUTTERS
AS REQUIRED FOR
DRAINAGE.
NEW 1/2" SHEATHING AS
REQUIRED BY SHINGLE MANUF.
ADD BLOCKING BOTH
DIRECTIONS AS NEEDED TO
SUPPORT NEW SHEATHING
ADD BLOCKING AS NEEDED TO SUPPORT
NEW SHEATHING
SNOW GUARD - SNOW
RETENTION SYSTEM
6" M
IN
EXISTING BRICK
MASONRY WALL -
PROTECT.
TERM BAR FASTENED APPROX. 12" O.C.
ICE AND WATER
SHIELD
UNDERLAYMENT
SHEET METAL FLASHING
SYNTHETIC SLATE
SHINGLE
SYNTHETIC SLATE SHINGLE
NEW 1X6 WD TRIM TO
MATCH EXISTING SIZE
AND PROFILE- PRIME
AND PAINT.
COLOR TO MATCH
EXISTING
SEALANT
ICE AND WATER SHIELD
UNDERLAYMENT
SHEET METAL PARAPET CAP-
MATCH EXISTING CAP PROFILE
1/2" PLYWOOD SHEATHING
EXISTING PLANK SHEATHING
SHEET METAL FLASHING
COUNTER FLASHING
INSTALL COMPATIBLE SEALANT
BEHIND MEMBRANE
M
IN
RIDGE TILE
RIDGE VENT
STAINLESS STEEL FASTENERS
1/2" PLYWOOD SHEATHING OVER EXISTING
PLANK SHEATHING - PROVIDE 1" GAP ON BOTH
SIDES OF RIDGE BEAM- CUT BACK SHEATHING IF
GAP DOES NOT CURRENTLY EXIST.
SYNTHETIC SLATE SHINGLE
EXISTING STRUCTURE
ROOF 2
34' - 0"
ROOF 1
31' - 6"
ROOF 3
43' - 0"
6" DIAMETER
DOWNSPOUT.
NOTE: IMAGE OF EXISTING DOWNSPOUT
PATHWAY. NEW DOWNSPOUT TO SERVE
SAME ROOFS. SIMPLIFY NEW DS
PATHWAY AS MUCH AS POSSIBLE TO
ELIMINATE BENDS, PROVIDE POSITIVE
DRAINAGE AND MEET SMACNA
STANDARDS.
NEW GUTTER LOCATION.
EXISTING BRICK
MASONRY WALL -
PROTECT.
SYNTHETIC SLATE SHINGLE
NEW 1X6 WD TRIM TO
MATCH EXISTING SIZE
AND PROFILE- PRIME
AND PAINT.
ICE AND WATER SHIELD
UNDERLAYMENT
SHEET METAL PARAPET CAP-
MATCH EXISTING CAP PROFILE
TERM BAR FASTENED APPROX. 12" O.C.
ICE AND WATER SHIELD UNDERLAYMENT
SHEET METAL FLASHING
SYNTHETIC SLATE
SHINGLE
SEALANT
1/2" PLYWOOD SHEATHING
EXISTING PLANK SHEATHING
SHEET METAL FLASHING COUNTERFLASHING
INSTALL COMPATIBLE SEALANT
BEHIND MEMBRANE
M
IN
EXISTING WINDOW
EXISTING STONE SILL
F5
A4.00
EXISTING WINDOW
SURFACE MOUNT SHEET METAL
COUNTERFLASHING
SYNTHETIC SLATE SHINGLES
UNDERLAYMENT
1/2" PLYWOOD SHEATHING
EXISTING PLANK SHEATHING
EXISTING STONE SILL
SNOW GUARD - SNOW
RETENTION SYSTEM
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
C op yr ig ht
M
A A rc hi te ct ur e
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000
MA Architecture No.:
Date:
www.kpff.com
Ph. 515 279 3900
Des Moines, Iowa 50309
604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
7/
/2
1:
:2
P
M A ut od es k
D oc s:
//0
.2
2_ D
A S
M P
C F
B U
IL
D
IN
G
R O
O F
R E
P
LA
C E
M E
N T
/0
.2 2_
D A
S M
P C
F B
U
IL
D
IN
G
R
O O
F R
E P
LA
C
E M
E N
T _R
.r vt
.0
D O
C M
P C
F
B U
IL
D
IN
G
R O
O F
R E
P L
A C
E M
E N
T
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
A4.00
DETAILS
052.22
06.21.2023
1 1/2" = 1'-0" A1
EAVE/GUTTER DETAIL - TYPICAL
1 1/2" = 1'-0"
A5
BRICK PARAPET/GABLE EDGE DETAIL -
TYPICAL
1 1/2" = 1'-0" A9
RIDGE DETAIL - TYPICAL
1/2" = 1'-0" E1
ENLARGED ELEVATION DIAGRAM -
GUTTER
1 1/2" = 1'-0" F5
SECTION DETAIL - @ ARCHED WINDOW
3/4" = 1'-0"
F9
ENLARGED ELEVATION - ARCHED
WINDOW
C
Dd
SHEET METAL VALLEY FLASHING
INVERTED V-GROOVE
VALLEY
1' - 2"
ICE AND WATER SHIELD OVERLAP
WITH VALLEY METAL AND EXTEND
6" BEYOND WIDTH
SYNTHETIC SLATE SHINGLE OVER
ICE AND WATER SHIELD
UNDERLAYMENT
EXISTING STONE PARAPET CAP
SLOPE
SLOPE
NEW METAL GUTTER
EXISTING STONE PARAPER CAP
4" MIN
EXTEND SHINGLES OVER
THE VALLEY METAL
0' - 6"
WRAP VERTICAL SHEET METAL
FLASHING AT CORNER
EXISTING ROOF
PENETRATION TO REMAIN.
2" M
IN
EXISTING SHEATHING.
NEW 1/2" PLYWOOD
SHEATING
NEW UNDERLAYMENT
ICE AND WATER SHIELD
ADDITIONAL UNDERLAYMENT PER
MANUF RECOMMENDATIONS
SHEET METAL BOOT FLASHING-
TYPICAL ALL ROOF PENETRATIONS
SYNTHETIC
SLATE SHINGLES
C1 A4.01
ICE AND WATER SHIELD TO
EXTEND 8" ON TOP AND
SIDES OF PENETRATION.
SHEET METAL BOOT
FLAHSING- TYPICAL ALL
ROOF PENETRATIONS
8"
3"
ICE AND WATER SHIELD TO
EXTEND 8" ON TOP AND
SIDES OF PENETRATION.
D
GUTTER
FI
EL
D
VE
RI
FY
3/
4"
OPEN VALLEY METAL
FLASHING WITH INVERTED
"V" GROOVE
SYNTHETIC SLATE
SHINGLES FIRST COURSE-
FOLLOWING MANUF.
INSTALLATION REQ. FOR
OVERHANG
0'
- 6
0'
- 6
ICE AND WATER SHIELD-
OVERLAP WITH VALLEY METAL
AND EXTEND 6" BEYOND WIDTH
3/4"
REMOVE AND SALVAGE HOODS. REPAIR HOODS AS REQUIRED AND
RE-INSTALL IN SAME LOCATION WITH NEW ROOF INSTALLATION.
COORDINATE NEW WORK WITH ABATEMENT SCOPE OF WORK.
ICE AND WATER SHIELD UNDERLAYMENT
SHEET METAL FLASHING
SYNTHETIC SLATE
SHINGLE
SEALANT
1/2" PLYWOOD SHEATHING
EXISTING PLANK SHEATHING
EXISTING LOUVER
EXISTING STONE SILL
EXISTING STONE SILL AND LOUVER
IN THESE LOCATIONS PROVIDE CUT-IN
FLASHING- FOLLOW BOTTOM OF STONE
SILL AND EDGE OF ROOFLINE. PROVIDE
SEALANT AT CUT-IN.
SHEET METAL FLASHING AND
COUNTERFLASHING
SNOW GUARD - SNOW RETENTION
SYSTEM.
ADD BLOCKING AS NEEDED TO SUPPORT
NEW SHEATHING.
SYNTHETIC SLATE SHINGLE
EXISTING MASONRY WALL TO REMAIN. PROTECT
DURING CONSTRUCTION. REPORT ANY DAMAGE
IMMEDIATELY TO OWNER.
EXISTING PAINTED SOFFIT AND MOLDINGS.
ICE AND WATER SHIELD UNDERLAYMENT
EAVE METAL FASCIA
AT LOCATION WHERE SNOW APRON WAS
DEMOLISHED PROVIDE NEW BLOCKING AND
SHEATHING-THICKNESS TO MATCH EXISTING
SHEATHING
EXISTING WD FASCIA- PAINT AFTER
DEMOLITION PRIOR TO NEW INSTALLATION
COLOR TO MATCH EXISTING
NEW GUTTER- CONFIRM SIZING BASED
ON 100 YEAR IOWA RAINFALL. SLOPE
GUTTERS AS REQUIRED FOR DRAINAGE.
NEW 1/2" SHEATHING AS
REQUIRED BY SHINGLE MANUF.
E10 A4.01
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000 MA Architecture No.:
Date:
www.kpff.com Ph. 515 279 3900 Des Moines, Iowa 50309 604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
6/2 1/2
3 2
:57 :33
P M
Au tod es k D oc s:/
/05 2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T/
2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T_
R2 2.r vt
.0
-D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
A4.01
DETAILS
052.22
06.21.2023
1" = 1'-0"E1
ENLARGED PLAN - ROOF VALLEY AT
PARAPET
3/4" = 1'-0"C1 PENETRATION SECTION - TYPICAL
3/4" = 1'-0"A1
ENLARGED PLAN - PENETRATION -
TYPICAL
3/4" = 1'-0"A4 ENLARGED PLAN - GUTTER
1 1/2" = 1'-0"A7 DETAIL - COPPER VENTILATION HOOD
1 1/2" = 1'-0"E10 SECTION DETAIL - @ LOUVER
1 1/2" = 1'-0"E6
ENLARGED ELEVATION - LEVEL 3
LOUVER
1 2 3 4 5 6 7 8 9 10 11 12 13 14
B
A
C
D
E
F
G
H
J
K
Co py rig ht
M
A Ar ch ite ctu re
In c.
1201 Keosauqua Way, Ste.101 Des Moines, Iowa 50309 Ph. 515 473 4834
Revisions
925000 MA Architecture No.:
Date:
www.kpff.com Ph. 515 279 3900 Des Moines, Iowa 50309 604 Locust Street, Ste. 202
STRUCTURAL ENGINEER
KPFF CONSULTING ENGINEERS
Activity ID:
6/2 1/2
3 2
:58 :04
P M
Au tod es k D oc s:/
/05 2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T/
2.2
2_
DA
S
MP
CF
B
UI
LD
IN
G
R
OO
F
RE
PL
AC
EM
EN
T_
R2 2.r vt
.0
-D O
C M
PC
F
B U
IL
D
IN
G
R O
O F
R
EP
LA
C
EM
EN
T
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
A5.00
PHOTOS OF EXISTING
052.22
06.21.2023
PHOTO 1 PHOTO 2 PHOTO 3 PHOTO 4 PHOTO 5 PHOTO 6 PHOTO 7
PHOTO 8 PHOTO 9 PHOTO 10 PHOTO 11 PHOTO 12 PHOTO 13 PHOTO 14
PHOTO 15 PHOTO 16 PHOTO 17
PHOTO 24
PHOTO 18 PHOTO 19
PHOTO 25
PHOTO 20 PHOTO 21
PHOTO 22 PHOTO 23
EXISTING PHOTO NOTES:
THE IMAGES DEPICTED ARE NOT EXHAUSTIVE REPRESENTATIONS OF ALL EXISTING CONDITIONS.
THE CONTRACTOR MUST EXERCISE DUE DILIGENCE IN DOCUMENTING THE EXISTING CONDITIONS
TO PREVENT ADDITIONAL COSTS OR PROJECT DELAYS.
| Sheets |
| A1.00 - ROOF PLAN - NEW |
| A2.00 - EXTERIOR ELEVATIONS |
| A4.00 - DETAILS |
| A4.01 - DETAILS |
| A5.00 - PHOTOS OF EXISTING |
| G0.00 - COVER |
| G0.01 - ABBREVIATIONS, SYMBOLS, SHEET LIST, SITE ACCESS PLAN |
| AD1.00.Abatement Demo Plan.6.21.23.pdf |
| Sheets and Views |
| Layout1 |
| A2.00_alt_R.pdf |
| Sheets |
| A2.00 - EXTERIOR ELEVATIONS |
| Cover_alt.pdf |
| Sheets |
| G0.00 - COVER |
File details come from the government source that posted it. Updated .