This is a Request for Proposals issued by Bangor Township Schools in Bay City, Michigan, for a two-year standard maintenance agreement covering boiler repairs and HVAC maintenance services. The District seeks written proposals from qualified vendors to furnish skilled labor, materials, tools, and equipment for planned maintenance services running from July 1, 2026, through June 30, 2028. The scope of work encompasses approximately 700 hours annually across six facilities: Central Elementary, Lincoln Elementary, West Elementary, Christa McAuliffe Middle School, John Glenn High School, and John Glenn Campus Stadium, along with Edison Administration. Services include routine maintenance inspections, welding, troubleshooting, fire efficiency testing, pump maintenance, 24-hour emergency service availability, replacement parts, written reports, and remote alarming diagnostic services. The RFP specifies detailed procedures including startup/checkout inspections, annual inspections, mid-season running inspections, pump annual inspections, control system inspections, optimization services, and remote monitoring. Sealed bids are due May 26 at 3:00 PM, and individual meetings may be scheduled upon request to review expectations and maintenance schedules. The District reserves the right to reject any or all proposals and award the contract to the most qualified vendor.
The contract includes specific pricing requirements detailed in Schedule B, which must identify hourly rates for non-service agreement equipment (Monday–Friday, 8:00 AM–4:30 PM), control engineering hourly rates, mileage rates, truck charges (one per visit or per initial problem fix, with eight hours equaling one truck charge), and overtime rates with effective times. Parts and materials are not included in the contract price and must be separately invoiced with prior approval required for expenditures exceeding $250. Vendors must respond within two hours to emergency service calls; repeated failure to meet this standard may result in contract termination. The agreement includes a 30-day cancellation clause for both parties and preferential service over non-contract customers. Additionally, an extra 576 hours are allocated annually for Tridium Control System updates and maintenance across the district, with eight rolling hours per building monthly. All required attachments include a Familial Relationship Disclosure Form (per Michigan Public Act 232 of 2004) and an Iran Economic Sanctions Act affidavit, both notarized.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for Proposals Two – Year Standard Maintenance
Agreement
Bangor Township Schools Bay City, MI 48706
Issued By: Bangor Township Schools 3359 E. Midland Rd Bay City, MI 48706 Attn: Casey Hamel, Finance Director
Proposal Due: Sealed Bid on May 26th @ 3:00 PM.
Please send Sealed Bid to the address above.
Meeting: Individual Meetings may be scheduled upon request to go over the expectations, details, tasks, and what the maintenance schedules entail completely.
REQUEST FOR PROPOSALS FOR
BOILER REPAIRS & MAINTENACE SERVICES
FOR BANGOR TOWNSHIP SCHOOLS
Purpose:
- We are requesting written proposals from companies who can furnish planned maintenance services on our boilers. These services shall run from July 1, 2026 until June 30, 2028.
- All companies submitting proposals must furnish skilled labor, materials (as noted), tools, equipment necessary to perform the task and all else, reasonably implied, as necessary for the prompt and satisfactory completion of this contract.
- The District reserves the right to reject any or all proposals, or to award the contract to the most qualified vendor.
- The District reserves the right to request clarification of information submitted and to request additional information from firms submitting proposals.
- You are bidding on providing a maintenance service for an average of 700 hours of work per year. This inquires all calls, services, and maintaining the district’s entire HVAC system.
Scope of Work:
- Scheduled Maintenance Service Program o Routine maintenance inspections are performed throughout the year o Welding as needed o Troubleshooting boilers as needed o Fire efficiency testing and adjustments as needed o Maintaining water pumps / circulating pumps
- Emergency Service o Emergency service and repairs are available on a 24-hour basis
- Replacement Parts o Parts and materials shall be provided as authorized, by a customer representative, and invoiced in the addition to contract price
- Inspections o This coverage includes operating inspections and periodic maintenance inspections per year as indicated
- Written Reports o Written reports / work request will be provided in detail to the customer representative of the work being performed or inspection.
- Preferential service and contract service rate o This contract includes preferential service to the customer over non-contract customers. For work outside the scope of service, the specified contract rate applies. This rate will be provided and broken down in schedule B of the RFP.
Procedures:
- Vendors must provide a detailed description of the various procedures (startup / checkout, annual inspection service, annual maintenance, mid-season running inspection, pumps annual inspection, control system inspection, optimization services, and remote alarming diagnostic services)
- Technician shall lubricate all equipment where needed to permit bearing, gears and all contact wearing points to operate freely without undue wear
- Remote monitoring via controls
- CSD1 inspections on all boilers for the State of Michigan
- HVAC Inspection Report for mid-season run inspections
- Coils on all chillers on roof tops
- Refrigerant service form for any adding or removal of refrigerant per EPA mandate
Terms of the Agreement:
- This agreement shall remain in effect for a period of two (2) years.
- Both parties reserve the right to cancel this agreement, with cancellation in effect thirty (30) days after written notice is received by either party.
- The district has averaged roughly 700 hours a year maintaining the HVAC units that you see in schedule
A. This includes all on call services, fixing and updating the Trane Control System, and performing all scheduled maintenance listed in schedule A. This RFP is for all services needed for the 2 year contract.
When the district has an issue with its boiler system or any HVAC unit the vendor will be responsible for diagnosing the issue and fixing the problem. This all most occur in a reasonable time that is under the districts discretion our expectations is within (2) hours. Educating our students is our main priority and not having our facilities running at full capacity is a major issue. Failure to report in a timely manner in repeated offenses can result in the termination of the contract.
- Materials and parts are not covered under this agreement. Any parts needed to fix our HVAC system will need to be broken out in a detail invoice so the District can verify the expenditures. Parts that exceed the $250 threshold will need prior approval.
- Any work outside of this contract will need Districts approval before work is performed.
Services to be Rendered:
Schedule A
Central Elementary* 208 State Park Dr. Bay City, MI 48706
Equipment: 2 Aerco Boilers & 1 Trane Chiller, 21 Unitvents, 6- FTR Units, 6 VAV Units
Quantity Equipment Description Schedule
1 Chilled Water System Start-up Inspection Spring
1 Chilled Water System Comprehensive inspection Aug
1 Boiler System Annual Inspection Oct
2 Boilers Run Inspection Dec
2 Pumps Annual Inspection Oct
1 Tridium Control System Maintenance Inspection Aug
1 Tridium Control System System Optimization On-going
1 Tridium Control System Remote Alarm/Diagnostics On-going
Lincoln Elementary* 2771 N. Euclid Ave. Bay City, MI 48706
Equipment: 2 Aerco Boilers & 1 Trane Chiller, 2 Rooftops, 5- FTR, 1 Unitvents
1 Chilled Water System Start-up Inspection Spring
1 Chilled Water System Comprehensive inspection Aug
1 Boiler System Annual Inspection Oct
2 Boilers Run Inspection Dec
2 Pumps Annual Inspection Oct
1 Tridium Control System Maintenance Inspection Aug
West Elementary* 3175 E. Wilder Rd. Bay City, MI 48706
Equipment: 2 Aerco Boilers & 1 Trane Chiller, 3 Rooftops, 15 Unitvents, 5- VAV
1 Chilled Water System Start-up Inspection Spring
1 Chilled Water System Comprehensive inspection Aug
1 Boiler System Annual Inspection Oct
2 Boilers Run Inspection Dec
2 Pumps Annual Inspection Oct
1 Tridium Control System Maintenance Inspection Aug
Christa McAuliffe M.S.
3281 Keisel Rd. Bay City, MI 48706
Equipment: 2 Thermal Solutions & 1 Trane Chiller, 11 RTU, 1 Splitter, 2 AHU, 31 UnitVents, 2- Domestic Hot Water Heaters, 25 Exhaust Fans, 1 Fan Coil Unit
Quantity Equipment Description Schedule
1 Chilled Water System Start-up Inspection Spring
1 Chilled Water System Comprehensive inspection Aug
1 Boiler System Annual Inspection Oct
2 Boilers Run Inspection Dec
3 Pumps Annual Inspection Oct
1 Tridium Control System Maintenance Inspection Aug
John Glenn H.S.
3201 Kiesel Rd. Bay City, MI 48706
Equipment: 4 Thermal Solution Boilers, 2 Trane Chillers, 1 Cooling Tower, 9 RTU, 8 BCU, 7 AHU, 42 Uni-vents, 1 Splitter, 1 Energy Recovery Unit
Quantity Equipment Description Schedule
1 Chilled Water System Start-up Inspection Spring
1 Chilled Water System Comprehensive inspection Aug
1 Boiler System Annual Inspection Oct
4 Boilers Run Inspection Dec
6 Pumps Annual Inspection Oct
1 Tridium Control System Maintenance Inspection Aug
1 Tridium Control System System Optimization On-going
1 Tridium Control System Remote Alarm/Diagnostics On-going
1 Cooling Tower Drained / Cleaned/ put down yr. Yearly
1 Pool Boiler Inspections Dec
John Glenn Campus Stadium 3201 Kiesel Rd. Bay City, MI 48706
Equipment: 1 Heat pump, 1 Air Handler, 1 Mini-Split
1 Heat Pump (Concessions) Annual Inspection Yearly
1 Air Handler (Concessions) Annual Inspection Yearly
1 Mini-Split (Press Box) Annual Inspection Yearly
Edison Administration
3359 E. Midland Rd. Bay City, MI 48706
Equipment: 2 Boilers, 8 A/C Units
Quantity Equipment Description Schedule
1 Boiler System Annual Inspection Oct
2 Boilers Run Inspection Dec
1 Tridium Control System Maintenance Inspection Aug
1 Tridium Control System Maintenance Inspection Aug
• Tridium Control system will need to be updated and maintained for the entire district.
Additional
• 576 Hours Working on the Control Solutions Control System. With rolling hours if not fully used in that month. 8 hours a building rolling if the hours are not used to the next month. They will accumulate for additional jobs that might exceed the 8 hours a month
• 58 Exhaust Fans at John Glenn – Maintenance on these
Required Attachments Please provide the following:
1. Information requested in Schedule B
2. Familial Relationship Disclosure Form (Attachment A)
3. Iran Sanctions Act Form (Attachment B)
Schedule B:
- Standard Hours o ____________ / Hour for non-service agreement equipment Effective times: Monday through Friday. 8 A.M – 4:30 P.M.
____________ / Hour for Control Engineering
- Mileage Rate $ _________
- Truck Charge $ _________ *** One Truck Charge per visit / fixing the same initial problem / or if in district.
*** 8hrs = 1 truck charge
- List Overtime Rate / Effective Times:
ATTACHMENT A
Bangor Township Schools Familial Relationship Disclosure Statement
Important: This disclosure statement must be included with your bid as required by state law (Public Act 232 of 2004).
As required by Public Act 232 of 2004, all bids shall be accompanied by a sworn and notarized statement disclosing any familial relationship that exists between the owner or any employee of the bidder and any member of the Bangor Township School District board, intermediate school board, or board of directors or the superintendent of the school district, intermediate superintendent of the intermediate school district, or chief executive officer of the public school academy. Bangor Township Schools – board, intermediate school board, or board of director shall not accept a bid that does not include this sworn and notarized disclosure statement.
I state that no familial relationship exists between the owner or any employee of the company and any member of the Bangor Township School District board, intermediate school board, or board of directors or the superintendent of the school district, intermediate superintendent of the intermediate school district, or chief executive officer of the public school academy. If such a relationship exists, please explain:
By: _________________________________ Signature
Title: _________________________________
Date: _________________________________
Subscribed and Sworn to Before Me:
This ______ day of ______________, A.D., in and for the County of ___________, Michigan.
My commission expires ______________.
Signature of Notary
ATTACHMENT B
Affidavit of Bidder Iran Economic Sanctions Act
The undersigned, the owner or authorized officer of _____________ (the “Bidder”), pursuant to the Iran Economic Sanctions Act (MCL 129.313), hereby represents and warrants that it is not an “Iran linked business”.
Bidder: ______________________________
By: ______________________________
Its: ______________________________
STATE OF MICHIAN )
) ss.
COUNTY OF _____________ )
The instrument was acknowledged before me on the ___ day of _________, 20___, by
_________________________________, Notary Public
My Commission Expires: _________________________
Acting in the County of: _________________________
File details come from the government source that posted it. Updated .