RCC 260-B4260-073 M24RC178 Project Drawings 2025-02-24.pdf
PDF 3 MB Posted
- Solicitation number
- 88702
- Issued by
- Gloucester County, Roanoke County, Virginia
About this file
This is a set of architectural drawings from Grimm + Parker Architects for a window replacement project at two Rappahannock Community College (RCC) campuses - the Glenns Campus at 12745 College Drive in Glenns, Virginia and the Warsaw Campus at 52 Campus Drive in Warsaw, Virginia. The project, identified as DEB #260-B4260-073, involves replacing existing windows with new aluminum storefront systems at both campus locations. The bid set is dated February 24, 2025 and includes detailed architectural plans, demolition plans, elevations, and frame details for both buildings. The scope includes removal of existing windows, frames, clips, sealants and blocking, and installation of new storefront systems with manual translucent roller shades and blackout shades in specified locations.
The project falls under the Virginia Community College System and must comply with the 2021 Virginia Existing Building Code, 2021 Virginia Construction Code, and 2024 Virginia Construction & Professional Services Manual. Both buildings are classified as Type IIB construction with Business (B) occupancy. The project is exempt from the High Performance Buildings Act as the renovated area is less than 5,000 gross square feet. The drawings note lead and asbestos disclosure requirements, with the owner responsible for asbestos abatement prior to construction. Technical specifications include 1" insulating glass systems with low-E coating and custom color exterior sealants to be selected by the architect.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A
T e l:
-2
-5
DEB #
260-B4260-073
RC
C
5 C oll eg e D riv e, Gl en ns , V irg ini a
2/24/2025
BID SET
GP #22006.24
VIRGINIA COMMUNITY COLLEGE SYSTEM
300 Arboretum Place, Suite 200 Richmond, Virginia 23236
OWNER ARCHITECT
D E S I G N T E A M
BID SET 2/24/2025
DATE DESCRIPTION
X. TONG WANG, RA
Capital Outlay Program Manager twang@vccs.edu Tel: (804) 819-4919
RAPPAHANNOCK COMMUNITY COLLEGE
Glenns Campus 12745 College Drive, Glenns, Virginia
COLLEGE
RICHARD P. LEWTER
Facilities Manager,Glenns Campus
RLEWTER@rappahannock.edu Tel: (804) 758-6840
GRIMM + PARKER ARCHITECTS
123 East Main St, Second Floor Charlottesville, Virginia 22902
Annette McDaniels AIA, CCCA, LEED AP BD+C Associate Principal amcdaniels@gparch.com Tel: (434) 270-0141
02/21/2025
RCC GLENNS CAMPUS
WINDOW REPLACEMENT
12745 College Drive, Glenns, Virginia
RCC - WARSAW CAMPUS
WINDOW REPLACEMENT
52 Campus Dr, Warsaw, Virginia
LIST OF DRAWINGS
TS TITLE SHEET
ARCHITECTURAL
A002 OVERALL FIRST FLOOR PLAN
D101 OVERALL FIRST FLOOR DEMOLITION PLAN
A101 PARTIAL FIRST FLOOR PLAN
A102 PARTIAL FIRST FLOOR PLAN
A201 BUILDING ELEVATIONS
A305 FRAME ELEVATIONS
LIST OF DRAWINGS
TS TITLE SHEET
ARCHITECTURAL
A002 OVERALL FIRST FLOOR PLAN
A003 OVERALL FIRST FLOOR PLAN - ANNEX
D101 OVERALL FIRST FLOOR DEMOLITION PLAN
D102 OVERALL FIRST FLOOR DEMOLITION PLAN - ANNEX
A101 PARTIAL FLOOR PLAN
A102 PARTIAL FLOOR PLAN
A103 PARTIAL FLOOR PLAN
A201 BUILDING ELEVATIONS
A202 BUILDING ELEVATIONS - ANNEX
A305 FRAME ELEVATIONS
VICINITY MAP LOCATION MAP
EXISTING CLASSROOM BUILDING
RAPPAHANNOCK
COMMUNITY COLLEGE
E LEWIS B PULLER MEM HWY
C O
LLE
G
E D
R
H W
Y
C O
LLE
G
E D
R
E LEWIS B PULLER
MEM HWY
HWY 17
RAPPAHANNOCK COMMUNITY COLLEGE
ABBREVIATIONS
VICINITY MAP LOCATION MAP
EXISTING CLASSROOM
BUILDING
RICHMOND ROAD
H W
Y
EXISTING ANNEX
BUILDING
DEB PROJECT CODE 260-B4260-073
W
IN
DO
W
R
EP
LA
CE
ME
NT
RAPPAHANNOCK COMMUNITY COLLEGE
WINDOW REPLACEMENT
CS
CO
MB
IN
ED
C
OV
ER
S
HE
ET
GLENNS CAMPUS AND WARSAW CAMPUS
EARTH
GRAVEL
CONCRETE
CONCRETE MASONRY UNITS
SOLID CONCRETE
MASONRY UNITS
BRICK
WOOD-FINISHED
WOOD ROUGH
PLYWOOD
GYPSUM BOARD
ACOUSTIC TILE
STEEL - LARGE SCALE
ALL METALS - SMALL SCALE
GLASS - LARGE SCALE
BATT INSULATION
RIGID INSULATION
CERAMIC TILE
CARPET
Above finished floor AFF Acoustic ACST Acoustic Panel Ceiling APC Addendum ADD Alternate ALT Aluminum AL Angle L Approximate APPROX Architecture, ARCH architectural Asbestos ASB Asphalt ASPH Assistant ASST Association ASSN Automatic AUTO Average AVG Base plate BP Basement BSMT Beam BM Bearing BRG Bedroom BR Benchmark BM Board BD Boiler BLR Bottom BOT Brick BRK Building line BL Building BLDG Built-up-roof BUR Cabinet CAB Carpet CPT Catalog CAT Ceiling height CH Ceiling CLG Center CTR Centerline CL Ceramic Tile CT Ceramic CER Chalkboard CB Clear CLR Closet CLO Coated CTD Cold rolled CR Column COL Company CO Composition COMP Concrete Masonry Unit CMU Concrete CONC Construction joint CJ Construction CONSTR "Continue, Continuous" CONT Corridor CORR Countersink CSK Cubic CU Curve(d) CRV Dampproofing DP Degree DEG Department(al) DEPT Detail DET Diagonal DIAG Diameter DIA Dimension DIM Dishwasher DW Dispenser DISP Door DR Double DBL Double-hung DH Down DN Downspout DS Drain DR Drawing DWG Each EA East E Electric Water Cooler EWC "Electric, electrical" ELEC Elevation EL Elevator ELEV Engineer ENGR Entrance ENTR
Maximum MAX Mechanical MECH Membrane MEMB Men M Metal MET, MTL Mezzanine MEZZ Minimum MIN Mirror MIR Miscellaneous MISC Mounted MTD Mounting MTG Necessary NEC Noise-reduction NRC coefficient Nominal NOM Non Combustible NC, NONCOM North N Not in Contract NIC Not to scale NTS Not available NA Number NO Office OFF On center OC Opening OPNG Opposite OPP Outside diameter OD Overall OA Overhead OVHD Page P Painted PTD Pair PR Panel PNL Partition PTN Percent PCT Perforate(d) PERF Permanent PERM Perpendicular PERP Piece PC Plastic Laminate PLAM Plastic Laminate PLAS.LAM Plate PL Plumbing PLMB Plywood PLYWD Point PT Polyvinyl chloride PVC Precast PRCST Prefabricated PREFAB Preliminary PRELIM Preparation, prepare PREP Program PRGM Projection Screen PS Project PROJ Property PROP Public Address PA Quality control QC Quality QUAL Quantity QTY Quarry Tile QT Radius RAD Rain Leader RL Received RCVD Receptacle RCPT Receptionist RECPT Recess(ed) REC Refer, reference REF Refrigerate, refrigerator REFR Reinforce REINF Reinforced concrete RC Remove RMV Repair RPR Required REQD Revise, revision REV Right hand RH Road RD Roof Drain RD Roof RF Roofing RFG Room RM Rubber tile floor RTF
Rubber RBR Schedule SCHED Schematic SCHEM Section SECT Service SVCE "Sheet, sheeting" SHT Shower SH Siding SDG Similar SIM Slope SL Sound-transmission STC class South S Speaker SPKR Specification SPEC Sprinkler SPR Square SQ Stainless steel SS Standard STD Standpipe SP Steel STL Storage STOR Structural Glazed SGFT Facing Tile Structural, structure STRUCT Substitute SUBST Surface SURF Suspend(ed) SUSP Switch SW Symmetrical SYM System SYS Tackboard TB Tackstrip TS Telephone TEL Television TV Temporary TEMP Terrazzo TER Thick THK Through THRU Toilet T Tongue and groove T&G Top and bottom T&B Top chord TC Top of Masonry Parapet TMP Top of Bearing TOFB Top of Steel T.O.S.
Topping TOPG Total TOT Transformer XFMR Transom TR Transparent TRANS Tread TRD Threshold THRESH Typical TYP Underground UG Underwriters UL Laboratories Unfinished UNF Unit Ventilator UV Unless Otherwise Noted UON Urinal UR US Gypsum Company USG Verify in Field VIF Vertical VERT Vestibule VEST, V Vinyl Reducing Strip VRS Vinyl Composite Tile VCT Vinyl asbestos tile VAT Wardrobe WARD Water closet WC Waterproof WP Weight WT Welded WLD Welded Wire Mesh WWM With W/ Without W/O Women W Wood WD Wrought Iron WI
Equal EQ Equipment EQUIP Exhaust EXH Existing EXIST Existing to Remain ETR Expansion joint EXP JT Exposed EXP Exterior EXT Fabricate FAB Face of Stud F. OF S.
Fan Coil Unit FCU Fiberglass-reinforced FRP plastics Finish FIN Finished Floor FF Fire Extinguisher FE Fire Extinguisher & FEC Cabinet Fire Retardant Treated FRT Fireproof FPRF Fixture FXTR Flange FLG Flashing FL Floor FL Floor drain FD Flooring FLG Fluorescent FLUOR Footing FTG Foundation FDN Furnish(ed), furniture FURN Furring FURR Gage (gauge) GA Galvanize(d) GALV Galvanized Iron GALVI Glazed Wall Tile GWT Grab Bar GB Grade GR Gravel GVL Gypsum Wallboard GWB Gypsum GYP Handicapped HC Hardware HDW Heating ventilating and HVAC air conditioning Height HGT High Point HPT High Performance HP High Performance HPC Coating Hollow Metal HM Horizontal HORIZ Include(d), inclusive INCL Incorporated INC Information INFO Inside diameter ID Install(ed), installation INSTL Insulation INSUL Interior INT Janitor JAN Joint JT Joist J, JST Junction box JB Knock down KD Laboratory LAB Lavatory LAV Left Hand LH Left L Length LG Level LVL Light LT Machine MACH Maintenance MAINT Manager MGR Manual MNL Manufacturing MFG Markerboard MB Masonry opening MO Masonry MSNRY Master bedroom MBR Material MATL
B101a
SIM
SIM
A102 A103
DEPT.
ADD
GRID LINES
SECTIONS
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAILS IN PLAN/SECTION
ROOM NUMBER
DOOR NO. ON PLAN
H.M. FRAME NO.
ON PLAN
REVISION: TYPE =
A.S.I/P.R./C.C.D./ADD.
CASEWORK
(FURNISHING PLANS ONLY)
ALUM. FRAME/WINDOW
TYPE
WALL TYPE
# # INTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
A3ROOM NAME
B101a
REF SHEET
NUMBER
REF SHEET NUMBER
NOT IN SCOPE
NOT IN SCOPE
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
TS
TI
TL
E S
H E
E T
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
LIST OF DRAWINGS
TS TITLE SHEET
ARCHITECTURAL
A002 OVERALL FIRST FLOOR PLAN
D101 OVERALL FIRST FLOOR DEMOLITION PLAN
A101 PARTIAL FIRST FLOOR PLAN
A102 PARTIAL FIRST FLOOR PLAN
A201 BUILDING ELEVATIONS
A305 FRAME ELEVATIONS
SYMBOLS OF MATERIALS
ABBREVIATIONS
1/16" = 1'-0"TSA201
A13 CODE STUDY PLAN - FIRST FLOOR
VIRGINIA COMMUNITY COLLEGE SYSTEM
300 Arboretum Place, Suite 200 Richmond, Virginia 23236
OWNER ARCHITECT
VICINITY MAP LOCATION MAP
LEAD DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED
TO THE EXTENT POSSIBLE.
DRAWING KEY
EXISTING CLASSROOM BUILDING
HIGH PERFORMANCE BUILDNG ACT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE
BECAUSE THE RENOVATED BUILDING AREA IS NOT GREATER THAN 5,000 GROSS SQUARE FEET.
PROJECT NAME AND LOCATION
NAME RAPPAHANNOCK COMMUNITY COLLEGE - WINDOW REPLACEMENT
STREET ADDRESS 12745 COLLEGE DRIVE
COUNTY GLOUCESTER COUNTY
CITY, STATE GLENNS, VA
PROJECT DESCRIPTION: WINDOW REPLACEMENT ON AN EXISTING BUILDING AT RCC.
THERE IS NO WORK INSIDE THE BUILDING - NO CHANGE IN OCCUPANCY OR OCCUPANTS
APPLICABLE CODES
BUILDING CODE 2021 Part 2, VIRGINIA EXISTING BUILDING CODE (VEBC), Level 1
2021 VIRGINIA CONSTRUCTION CODE (VCC)
2024 VIRGINIA CONSTRUCTION & PROFESSIONAL SERVICES MANUAL (CPSM)
ACCESSIBILITY ADA90-TITLE II,Scoping Requirements of the Department of Justice’s 2010 ADA Standards for Accessible Design, dated September 15, 2010 and technical design are Chapters 1 and 3 thru 11 of Standards for Accessible and Usable Buildings and Facilities (ICC A117.1-2017) approved March 28, 2017
BUILDING USE AND CONSTRUCTION CLASSIFICATION
VCC
USE GROUP: B, BUSINESS 304.1
BUILDING AREA (PER VCC): 55,158 SF (92,000 SF ALLOWABLE)
PROPOSED CONSTRUCTION TYPE TYPE IIB (EXISTING)
ALLOWABLE BUILDING HEIGHT/STORIES: 75' (VCC TABLE 504.3), 3 STORIES (VCC TABLE 504.4)
ACTUAL BUILDING HEIGHT/STORIES: 20' MAXIMUM, 1 STORY
BUILDING VOLUME: 1,103,160 CUBIC FEET (EXISTING)
APPLICABLE CODES AND TABULATIONS
RAPPAHANNOCK
COMMUNITY COLLEGE
E LEWIS B PULLER MEM HWY
C O
LLE
G
E D
R
H W
Y
C O
LLE
G
E D
R
E LEWIS B PULLER
MEM HWY
HWY 17
RAPPAHANNOCK COMMUNITY COLLEGE
DEB PROJECT CODE 260-B4260-073
D E S I G N T E A M
RCC GLENNS CAMPUS
WINDOW REPLACEMENT
BID SET 2/24/2025
12745 College Drive, Glenns, Virginia
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE AREA INDICATED. THE ASBESTOS INSPECTION REPORT IS INCLUDED IN SECTION 02 80 00 IN THE PROJECT SPECIFICATIONS. THE OWNER SHALL SUBMIT AN APPLICATION FOR PERMIT TO HAVE THE ASBESTOS-CONTAINING MATERIALS ABATED BY A LICENSED ASBESTOS CONTRACTOR UNDER A SEPARATE CONTRACT USING APPROVED PROCEDURES PRIOR TO ISSUING A NOTICE TO PROCEED TO THE GENERAL CONTRACTOR. ANY ACM THAT IS TO REMAIN AND THE NEW NON ASBESTOS-CONTAINING MATERIAL SHALL BE LABELED ACCORDINGLY. THE ASBESTOS ABATEMENT CONTRACTOR SHALL MARK UP THE AS-BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE ASBESTOS WAS ABATED, AREAS WHERE ASBESTOS WAS ENCAPSULATED, AND AREAS WHERE ACM EXIST BUT WERE LEFT IN PLACE. THE GENERAL CONTRACTOR SHALL REVIEW AND CERTIFY THE LOCATIONS WHERE ACM WAS ABATED, AREAS WHERE ACM WAS ENCAPSULATED AND AREAS WHERE ACM WAS LEFT IN PLACE AS MARKED ON THE AS-BUILT
DRAWINGS AND WILL PROVIDE THE DRAWINGS TO THE ARCHITECT.
DATE DESCRIPTION
X. TONG WANG, RA
Capital Outlay Program Manager twang@vccs.edu Tel: (804) 819-4919
RAPPAHANNOCK COMMUNITY COLLEGE
Glenns Campus 12745 College Drive, Glenns, Virginia
COLLEGE
RICHARD P. LEWTER
Facilities Manager,Glenns Campus
RLEWTER@rappahannock.edu Tel: (804) 758-6840
GRIMM + PARKER ARCHITECTS
123 East Main St, Second Floor Charlottesville, Virginia 22902
Annette McDaniels AIA, CCCA, LEED AP BD+C Associate Principal amcdaniels@gparch.com Tel: (434) 270-0141
02/21/2025
N
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED
OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND
BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS
ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS
OTHERWISE NOTED.
2. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY
ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. NO DRAWING SHALL HAVE
PRECEDENCE ONE OVER THE OTHER. IN THE EVENT OF A CONFLICT IN THE DOCUMENTS,
THE CONTRACTOR SHALL SEEK THE INTERPRETATION OF THE ARCHITECT. THE
CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL SUCH INTERPRETATION IS
OBTAINED. IF THE CONTRACTOR PROCEEDS WITHOUT CLARIFICATION, THE CONTRACTOR
WILL BE RESPONSIBLE TO REMOVE AND REPLACE ANY WORK NOT CONFORMANCE WITH
THE ARCHITECT'S DIRECTION WITHOUT ADDITIONAL COST TO THE OWNER. IN THE EVENT
OF A CONFLICT IN THE DRAWINGS OR SPECIFICATIONS, BIDDERS SHALL SEEK
CLARIFICATION FROM THE ARCHITECT. RESOLUTIONS TO SUCH CONFLICTS WILL BE
ISSUED THROUGH ADDENDA TO THE BID DOCUMENTS. IF CLARIFICATION FROM THE
ARCHITECT IS NOT RECEIVED THROUGH AN ADDENDUM PRIOR TO THE RECEIPT OF BIDS,
THE BIDDER SHALL ASSUME THE MORE COSTLY REQUIREMENT APPLIES, AND THE
AWARDED CONTRACTOR SHALL SEEK CLARIFICATION FROM THE ARCHITECT PRIOR TO THE
EXECUTION OF THE WORK.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE
ARCHITECT FOR CLARIFICATION.
4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER
MEASUREMENT, CONSULT THE ARCHITECT FOR CLARIFICATION.
5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS
OF SIMILAR USE ELSEWHERE IN THE BUILDING,
6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE
REFERENCED AS WELL AS ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR
SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN.
THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY
SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE
ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE
CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS,
WINDOWS, LOUVERS, GRILLES, MECHANICAL WORK, ETC. TO FIT TIGHT AND BE
THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED
OR OTHERWISE WATERPROOF SEALED.
9. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF
WINDOWS, AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION.
PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A
COMPLETE INSTALLATION.
10. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK
PERTAINING TO THEIR PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE
WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS.
REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
11. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED /
TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE
FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE
PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER
FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON
THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST
SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR
PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER
OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST
NEVERTHELESS INCLUDE THE ITEM IN QUESTION IN THEIR BID, CONSIDERING IT THE SAME
AS THE TAGGED SYMBOL MOST NEARLY RESEMBLING THE UNTAGGED SYMBOL BASED ON
ITS SHAPE, SIZE, LINEWEIGHT(S), LOCATION, AND SCHEDULED USAGE IN SPACES OF
SIMILAR FUNCTION. THE CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE
ARCHITECT PRIOR TO PROCEEDING WITH SHOP DRAWINGS.
GENERAL NOTES
KEY PLAN
AREA A AREA B
AREA C
G10 A201
L13 A201
E10 A201
J13 A201
OFFICE
105E
OPEN OFFICE
OFFICE
105D
STORAGE
105F
OFFICE
119C
OFFICE
119B
OFFICE
105G
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
Room
131B
Room
131D
Room
131E Room
133E
Room
Room
133A
Room
Room
132A
Room
144A
Room
Room
Room
146A
Room
140C
Room
140D
Room
Room
150C
Room
151C
Room
Room
152A
Room
154A
Room
Room
Room
Room
Room
Room
Room
Room
Room
Room
108Q Room
108P
Room
108E
Room
Room
108D
Room
105C
Room
105B
Room
105A Room
Room
100B
Room
Room
100A
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A002
O V
E R
A
LL
F
IR
S T
FL
O
O R
P
LA
N
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
1/16" = 1'-0"A002A201
B16 OVERALL FIRST FLOOR PLAN
0 8' 16'4'
DATE DESCRIPTION
KEY PLAN
AREA A AREA B
AREA C
G10 A201
L13 A201
E10 A201
J13 A201
OFFICE
105E
OPEN OFFICE
OFFICE
105D
STORAGE
105F
OFFICE
119C
OFFICE
119B
OFFICE
105G
NOTE 2
NOTE 1
NOTE 2
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 2
NOTE 1
NOTE 3
NOTE 1
Room
131B
Room
131D
Room
131E Room
133E
Room
Room
133A
Room
Room
132A
Room
144A
Room
Room
Room
146A
Room
140C
Room
140D
Room
Room
150C
Room
151C
Room
Room
152A
Room
154A
Room
Room
Room
Room
Room
Room
Room
Room
Room
Room
108Q Room
108P
Room
108E
Room
Room
108D
Room
105C
Room
105B
Room
105A
Room
100B
Room
Room
100A
1. DOUBLE WINDOW "A" REMOVE EXISTING SET OF WINDOWS, INCLUDING FRAME, CLIPS, SEALANT, EXISTING BLOCKING, ETC.
2. QUADRUPLE WINDOW "A" REMOVE EXISTING SET OF WINDOWS, INCLUDING FRAME, CLIPS, SEALANT, EXISTING BLOCKING, ETC.
3. DOUBLE WINDOW "B" REMOVE EXISTING SET OF WINDOWS, INCLUDING FRAME, CLIPS, SEALANT, EXISTING BLOCKING, ETC.
DEMOLITION KEY NOTES
1. ALL WORK SHOWN IS EXISTING TO REMAIN UNLESS NOTED OR INDICATED AS DASHED
LINES TO BE REMOVED. THE EXTENT OF DEMOLITION WORK SHALL INCLUDE ALL
INCIDENTAL DEMOLITION WORK NECESSARY TO PROPERLY PROVIDE ALL NEW WORK
SHOWN AND SPECIFIED, TO INCLUDE MECHANICAL, ELECTRICAL, & PLUMBING ITEMS.
2. DEMOLITION WORK SHOWN IS BASED ON EXISTING DRAWINGS AND INSPECTIONS. THE
CONTRACTOR SHALL VISUALLY INSPECT ALL EXISTING CONDITIONS, AND IS RESPONSIBLE
FOR PERFORMING THE INDICATED DEMOLITION WORK EVEN IF ACTUAL CONDITIONS
DIFFER FROM THESE SHOWN ON THE DRAWINGS.
3. DEMOLITION CONTRACTOR SHALL COORDINATE WITH NEW WORK SECTIONS FOR
ADDITIONAL INFORMATION RELATED TO EXTENT OF DEMOLITION.
4. REFER TO ALL OTHER DRAWINGS IN THIS SET FOR INCIDENTAL DEMOLITION WORK NOT
NOTED ON THE DEMOLITION PLANS.
5. THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGE ITEMS. THE CONTRACTOR
SHALL PROPERLY DISPOSE OF ALL CONSTRUCTION DEBRIS. DO NOT STOCKPILE DEBRIS
ON SITE.
6. ITEMS TO BE DEMOLISHED SHALL BE REMOVED COMPLETELY INCLUDING ALL ANCHORS,
HANGERS, FASTENERS, ADHESIVES, SEALANTS, ETC. FINISHES TO REMAIN SHALL BE
PATCHED, PAINTED, AND REPAIRED TO MATCH EXISITNG ADJACENT FINISHES.
7. REMOVE, PATCH AND REPAIR PORTIONS OF WALL PARTITIONS WHICH CONFLICT WITH NEW
WORK TO BE INSTALLED, EVEN IF NOT SPECIFICALLY NOTED TO BE DEMOLISHED ON
PLANS.
8. ALL EXISTING STRUCTURE SHALL REMAIN, UNLESS NOTED OTHERWISE.
9. TEMPORARILY SUPPORT ALL BEAMS, LINTELS, PORTIONS OF WALLS ETC., TO BE
DISTURBED BY DEMOLITION WORK, UNTIL THEY ARE RE-SUPPORTED BY NEW WORK.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF EXISTING
BUILDING ELEMENTS TO REMAIN THROUGHOUT SEQUENCE OF WORK. ANY DAMAGE TO
EXISTING BUILDING CONDITIONS SHOWN TO REMAIN SHALL BE RESTORED TO NEW WORK
CONDITION AT NO ADDITIONAL COST TO THE OWNER.
11. WHERE FINISHES ARE INDICATED TO BE REMOVED, REMOVAL SHALL INCLUDE ANY GROUT,
ADHESIVES, FASTENERS, AND ALL OTHER ITEMS USED TO ATTACH THE FINISHES TO THE
SURFACES THAT THEY COVER.
12. ANY FLOOR AREAS DAMAGED BY THE DEMOLITION CONTRACTOR SHALL BE PATCHED TO
MATCH EXISTING.
13. WHERE CEILINGS ARE TO BE REMOVED, REMOVE ALL CEILINGS SYSTEMS COMPLETE
INCLUDING GRID, TRIM HANGER, CLIPS, ETC. REUSE SALVAGED COMPONENTS WHERE
INDICATED. WHERE NEW CEILINGS ARE SPECIFIED, NO DOUBLE CEILINGS PERMITTED.
REMOVE ALL ORIGINAL CONCEALED CEILINGS WHERE ENCOUNTERED.
14. ALL EXISTING SURFACES TO REMAIN SHALL BE PROTECTED, PATCHED IF DAMAGED AND
CLEANED PRIOR TO APPLICATION OF FINISHES.
15. CONTRACTOR TO PROTECT ALL EQUIPMENT AND OTHER ELEMENTS IN AREA OF NEW OR
DEMOLITION WORK.
16. REMOVE ALL EXISTING WINDOW TREATMENTS: HORIZONTAL BLINDS, SHADES AND THE
LIKE.
17. REMOVE AND REPLACE ALL EXISTING, DAMAGED SILLS.
GENERAL DEMOLITION NOTES
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
D101
O V
E R
A
LL
F
IR
S T
FL
O
O R
D E
M O
LI
TI
O N
P
LA
N
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
0 8' 16'4'
1/16" = 1'-0"D101A201
C16 FIRST FLOOR - DEMOLITION PLAN
1. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF
MASONRY TO FACE OF GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF
GYPSUM BOARD.
2. PLAN LOCATION OF WINDOWS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS
DIAGRAMMATIC ONLY. REFER TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS
TO DETERMINE ACTUAL PLACEMENT OF WINDOW AND FRAME.
GENERAL PLAN NOTES
KEY PLAN
AREA A AREA B
AREA C
L13 A201
G7
A101 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
OFFICE
119B
OFFICE
105E
OFFICE
105D
STORAGE
105F
OFFICE
119C
OFFICE
105G
Room
131B
Room
131D
Room
131E
Room
133E
Room
Room
133A
Room
Room
132A
Room
108Q Room
108P
Room
108E
Room
Room
108D
Room
105C
Room
105B
Room
105A
Room
100B
Room
Room
100A
NOTE 1 NOTE 1
NOTE 1 NOTE 1 NOTE 1 NOTE 1
NOTE 1
NOTE 1
NUMBERED REMARKS
NOTE 1: PROVIDE MANUAL TRANSLUCENT ROLLER SHADES AT THIS FRAME OPENING.
NOTE 2: PROVIDE BOTH TRANSLUCENT AND BLACK-OUT SHADES AT THIS FRAME OPENING. BOTH ARE
MANUALLY-OPERATED.
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A101
P A
R
TI
A L
FI
R
S T
FL
O
O R
P
LA
N
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
0 4' 8'2'
1/8" = 1'-0"A101A201
D16 FLOOR PLAN - AREA A
AREA A AREA B
AREA C
L7
A102 A305
L7
A102 A305
L7
A102 A305
G7
A101 A305
G7
A101 A305
G7
A101 A305
L7
A102 A305
L7
A102 A305
G7
A101 A305
G7
A101 A305
Room
144A
Room
Room
Room
146A
Room
140C
Room
140D
Room
Room
150C
Room
151C
Room
Room
152A
Room
154A
Room
Room
Room
Room
Room
Room
Room
Room
Room
NOTE 2
NOTE 2
NOTE 2
NOTE 1
NOTE 1 NOTE 1 NOTE 1
NOTE 1
NOTE 1NOTE 1
NOTE 1
J7
A102 A305
J7
A102 A305
Room
NOTE 1NOTE 1
1. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF
MASONRY TO FACE OF GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF
GYPSUM BOARD.
2. PLAN LOCATION OF WINDOWS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS
DIAGRAMMATIC ONLY. REFER TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS
TO DETERMINE ACTUAL PLACEMENT OF WINDOW AND FRAME.
GENERAL PLAN NOTES
NUMBERED REMARKS
NOTE 1: PROVIDE MANUAL TRANSLUCENT ROLLER SHADES AT THIS FRAME OPENING.
NOTE 2: PROVIDE BOTH TRANSLUCENT AND BLACK-OUT SHADES AT THIS FRAME OPENING. BOTH ARE
MANUALLY-OPERATED.
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A102
P A
R
TI
A L
FI
R
S T
FL
O
O R
P
LA
N
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
0 4' 8'2'
1/8" = 1'-0"A102A201
D13 FLOOR PLAN - AREA B
1/8" = 1'-0"A102A201
A11 FLOOR PLAN - AREA C
1. NOT USED.
2. REFER TO LARGE SCALE ELEVATION DETAILS AND SPECS FOR MASONRY PATTERNS, BONDING, SPECIAL SHAPES AND
MORTAR COLOR PATTERNS.
3. PROVIDE SEALANT AT ALL INTERSECTIONS OF DISSIMILAR MATERIALS IN ACCORDANCE WITH THE SPECIFICATIONS. ALL
EXTERIOR SEALANTS TO BE A CUSTOM COLOR SELECTED BY THE ARCHITECT. MORE THAN ONE SEALANT COLOR MAY BE SELECTED FOR USE ALONG THE HEIGHT OF THE SAME JOINT TO MATCH ADJOINING MASONRY OR MORTAR.
(NOTES APPLY TO ALL ELEVATION SHEETS)ELEVATION NOTES
Level 1 0' - 0"
Level 2 13' - 0"
A18
A201 A201
E18
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
E18 Sim
A201 A201
Level 1 0' - 0"
Level 2 13' - 0"
Level 3 20' - 0"
H18
A201 A201
H18 Sim
A201 A201A18 Sim
A201 A201
A18 Sim
A201 A201
A18 Sim
A201 A201
Level 1 0' - 0"
Level 2 13' - 0"
E18 Sim
A201 A201
E18 Sim
A201 A201
A18 Sim
A201 A201
Level 1 0' - 0"
Level 2 13' - 0"
E18 Sim
A201 A201Level 1 0' - 0"
EXISTING BRICK PIER, TYP.
NEW ALUMINUM FRAMED
STOREFRONT SYSTEM, TYP.
EXISTING BRICK, TYP.
SF01 SF01
RESINOUS CEMENT COATING, TYP.
RESINOUS CEMENT COATING, TYP.
NOTE:
CONTRACTOR SHALL POWER
WASH ALL RESINOUS CEMENT
COATINGS AT NEW WINDOWS
Level 1 0' - 0"
EXISTING BRICK PIER, TYP.
NEW ALUMINUM FRAMED
STOREFRONT SYSTEM, TYP.
EXISTING BRICK, TYP.
SF01 SF01 SF01 SF01
RESINOUS CEMENT COATING, TYP.
RESINOUS CEMENT COATING, TYP.
NOTE:
CONTRACTOR SHALL POWER
WASH ALL RESINOUS CEMENT
COATINGS AT NEW WINDOWS
Level 1 0' - 0"
1313.5
EXISTING BRICK PIER, TYP.
NEW ALUMINUM FRAMED
STOREFRONT SYSTEM, TYP.
SF02SF02
EXISTING BRICK, TYP.
RESINOUS CEMENT COATING, TYP.
RESINOUS CEMENT COATING, TYP.
NOTE:
CONTRACTOR SHALL POWER
WASH ALL RESINOUS CEMENT
COATINGS AT NEW WINDOWS
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A201
B U
IL
D
IN
G
E
LE
V A
TI
O
N S
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
0 8' 16'4'
1/16" = 1'-0"A201A002
L13 SOUTH ELEVATION
1/16" = 1'-0"A201A002
J13 NORTH ELEVATION
1/16" = 1'-0"A201A002
G10 EAST ELEVATION
1/16" = 1'-0"A201A002
E10 WEST ELEVATION
1/4" = 1'-0"A201A201
E18 ELEVATION - DOUBLE "A" WINDOW ARRANGEMENT
1/4" = 1'-0"A201A201
A18 ELEVATION - QUAD "A" WINDOW ARRANGEMENT
1/4" = 1'-0"A201A201
H18 ELEVATION - DOUBLE "B" WINDOW ARRANGEMENT
NOTES APPLY TO ALL FRAME ELEVATION SHEETS
STOREFRONT NOTES
GLASS TYPE KEY
1. VERIFY ROUGH OPENINGS, INCLUDING BUT NOT LIMITED TO STRUCTURAL LINTEL LOCATIONS, PRIOR TO FABRICATION.
2. COORDINATE REQUIRED TOLERANCES IN ALL DIMENSIONS NEEDED TO MANUFACTURE AND INSTALL WINDOWS, STOREFRONT INCLUDING SUBFRAMES, AS REQUIRED.
3. CONTINUOUSLY SEAL ALL SIDES OF STOREFRONT AND SUBFRAMES ABUTTING DISSIMILAR MATERIALS AT JAMBS, HEADS, AND SILLS, TYPICALLY.
4. PROVIDE APPROPRIATE ANCHORAGE SYSTEM FOR ALL CONDITIONS. PROVIDE SUBFRAMING AS SHOWN ON DETAILS OR
SPECIFIED.
5. PROVIDE FOR THERMAL EXPANSION AT ALL FRAMING SYSTEMS.
6. COORDINATE FRAMES WITH PLAN WHEN MORE THAN ONE CONSTRUCTION DETAIL IS REFERENCED.
7. AS REQUIRED FOR DESIGN LOADING, MANUFACTURER TO PROVIDE MULLION REINFORCING AND VERTICAL EXTENSIONS UP
TO STRUCTURE ABOVE (ATTACHMENT TO STRUCTURE BY MANUFACTURER). SEE SECTIONS AND DETAILS FOR ADDITIONAL
WORK RELATING TO FRAMING SYSTEM.
8. IDENTIFICATION OF OPENING TYPES AS STOREFRONT IS BASED ON SYSTEM REQUIREMENTS OF A PARTICULAR MANUFACTURER. CONTRACTOR IS TO DETERMINE BEST APPLICATION OF SUBMITTED MANUFACTURER AND SYSTEM
BASED ON PERFORMANCE REQUIREMENTS, SIZE OF OPENING, AND INSTALLATION CONDITION.
9. CONTRACTOR TO COORDINATE REQUIRED TOLERANCES IN ALL DIMENSIONS NEEDED TO MANUFACTURE AND INSTALL STOREFRONT, INCLUDING SUBFRAMES, AS REQUIRED. CONTRACTOR MUST VERIFY ACTUAL DIMENSIONS IN THE FIELD WITH THOSE SHOWN ON ALL DRAWINGS, INCLUDING DETAILS SHOWN ON OTHER SHEETS, PRIOR TO FABRICATION.
10. NOT USED.
11. COORDINATE FRAMING SYSTEMS WITH AIR BARRIER TRANSITION MEMBRANE SYSTEM AND MANUFACTURER-
RECOMMENDED DETAILS FOR A COMPLETE AIR BARRIER SYSTEM.
G-1 NOT USED.
G-2 NOT USED.
G-3 NOT USED.
G-4 NOT USED.
G-5 1" INSULATING GLASS; CONSISTING OF
1/4" CLEAR GLASS, EXTERIOR LITE WITH LOW E COATING
1/2" AIR SPACE, AND
1/4" CLEAR GLASS
G-6 NOT USED.
G-7 NOT USED.
G-8 NOT USED.
G-9 1" INSULATING GLASS; SPANDREL UNIT CONSISTING OF
1/4" CLEAR GLASS, EXTERIOR LITE WITH LOW E COATING
1/2" AIR SPACE, AND
1/4" CLEAR GLASS, CERAMIC-COATED 4TH SURFACE
REMARKS
REFER TO FLOOR PLANS FOR LOCATIONS OF SHADING DEVICES.
2' - 8" 2' - 8"
SF01 SF01
SF01 SF01 SF01 SF01
2' - 8" 2' - 8"2' - 8" 2' - 8"
2' - 8" 2' - 8"
SF02 SF02
Level 1 0' - 0"
6'
8" 2'
8"
2" 5'
0"
2" 1'
2"
2"
2' - 8"
2" 2' - 4" 2"
G-5
G-5
B12
A305
B12
A305
B7
A305
B18
A305
G-9 AT LABS:
173, 175, 176
2'
8"
2" 1'
2"
2" 8'
4"
2" 1'
2"
2" 2' - 8"
2" 2' - 4" 2"
G-5
G-5
G-5
B12
A305
B12
A305
B7
A305
B18
A305
CONTRACTOR TO V.I.F.
EXISTING WALL CONSTRUCTION
PRE-FIN ALUM. STOREFRONT HIGH
PERFORMANCE SILL FLASHING W/ END DAM
AND WEEPS
PRE-FIN ALUM. STOREFRONT SYSTEM W/ 1"
INSULATED GLAZINGCONT. BACKER ROD AND SEALANT AT
FULL PERIMETER INT. AND EXT. -
COLOR TO MATCH FRAME, TYP.
LOCATE PRIMARY SEALANT LINE TO ENGAGE
TRANSITION MEMBRANE @ FULL PERIMETER OF
OPENING, TYP.
4 1/2" V.I.F. +/- 7 1/2"
EXISTING WALL CONSTRUCTION
(SHOWN GRAY), NO WORK
EXISTING ACCENT BRICK
(BEYOND), NO WORK
EXISTING RESINOUS CEMENT COATING
PRE-FINISHED SILL. NEW OR
EXISTING, REFER TO PLANS
SEALANT AT SILL,
COLOR TO MATCH
ADJACENT SURFACE
FINISHED JAMB (BEYOND)
CONTRACTOR SHALL CLEAN ALL
EXTERIOR, CONCRETE SILLS
NOTE:
ACTUAL CONSTRUCTION OF EXISTING WALL MAY VARY.
CONTRACTOR SHALL VERIFY IN FIELD
FURRED WALL MAY OCCUR. CONTRACTOR
TO VERIFY IN FIELD. INCREASE SIZE OF SILL
WHERE REQUIRED.
CASEWORK
(SHOWN DASHED) OCCURS
IN SOME LOCATIONS
CONT. BACKER ROD AND SEALANT AT FULL
PERIMETER INT. AND EXT. - COLOR TO MATCH
FRAME, TYP.
SHIM, AS REQ'D
PRE-FIN ALUM. STOREFRONT SYSTEM W/ 1"
INSULATED GLAZING
- 4
/2
1/ 2"
CONTINUOUS MULLION FILLER
- 7
/2
EXISTING WALL CONSTRUCTION
(SHOWN GRAY), NO WORK
EXISTING RESINOUS CEMENT COATING SILL
NOTE:
ACTUAL CONSTRUCTION OF EXISTING WALL MAY VARY.
CONTRACTOR SHALL VERIFY IN FIELD
PRE-FINISHED SILL. NEW OR EXISTING, REFER TO PLANS
CONTRACTOR TO V.I.F.
EXISTING WALL CONSTRUCTION
4 1/2" +/- 4 1/2" +/- 7 1/2"
SHIM, AS REQ'D
CONT. BACKER ROD AND SEALANT AT FULL PERIMETER
INT. AND EXT. - COLOR TO MATCH FRAME, TYP.
PRE-FIN ALUM. STOREFRONT SYSTEM
W/ 1" INSULATED GLAZING
CONTINUOUS MULLION FILLER
EXISTING WALL CONSTRUCTION (SHOWN GRAY), NO WORK
EXISTING RESINOUS CEMENT COATING
ROLLER SHADE, SEE PLANS/NOTES
EXISTING, GYP BOARD
WINDOW WELL BEYOND
EXISTING FINISHED
CEILING SYSTEM
CONTRACTOR TO V.I.F.
EXISTING WALL CONSTRUCTION
4 1/2" +/- 4 1/2" +/- 7 1/2"
SHIM, AS REQ'D
PRE-FIN ALUM. STOREFRONT SYSTEM
W/ 1" INSULATED GLAZING
CONTINUOUS MULLION FILLER
EXISTING WALL CONSTRUCTION
(SHOWN GRAY), NO WORK
EXISTING RESINOUS CEMENT
COATING
ROLLER SHADE, SEE PLANS/NOTES
NOTE:
ACTUAL CONSTRUCTION OF EXISTING WALL MAY VARY.
CONTRACTOR SHALL VERIFY IN FIELD
EXISTING, GYP BOARD
WINDOW WELL BEYOND
EXISTING FINISHED
CEILING SYSTEM CONT. BACKER ROD AND SEALANT AT
FULL PERIMETER INT. AND EXT. -
COLOR TO MATCH FRAME, TYP.
FURRRED WALL CONDITIONBLOCK WALL CONDITION
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A305
FR
A
M E
E
LE
V A
TI
O
N S
RC
C
GL
EN
NS
C
AM
PU
S W
IN
DO
W R
EP
LA
CE
ME
NT
5 C oll eg e D riv e, Gl en ns
, V irg ini a
2/24/2025
BID SET
GP #22006.24
SCALE 1/4" = 1'-0"STOREFRONT TYPES
3" = 1'-0"A305A305
B7 HEAD DETAIL - STOREFRONT @ EXISTING WALL
3" = 1'-0"A305A305
B18 SILL DETAIL - STOREFRONT @ EXISTING WALL
3" = 1'-0"A305A305
B12 JAMB DETAIL - STOREFRONT @ CMU
1/4" = 1'-0"A305A101
G7 PLAN - DOUBLE "A" WINDOW ARRANGEMENT
1/4" = 1'-0"A305A102
L7 PLAN - QUAD "A" WINDOW ARRANGEMENT
1/4" = 1'-0"A305A102
J7 PLAN - DOUBLE "B" WINDOW ARRANGEMENT
SF-01 - "A"SF-02 - "B"
HEAD, SILL, JAMB DETAILS
B101a
SIM
SIM
A102 A103
DEPT.
ADD
GRID LINES
SECTIONS
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAILS IN PLAN/SECTION
ROOM NUMBER
DOOR NO. ON PLAN
H.M. FRAME NO.
ON PLAN
REVISION: TYPE =
A.S.I/P.R./C.C.D./ADD.
CASEWORK
(FURNISHING PLANS ONLY)
ALUM. FRAME/WINDOW
TYPE
WALL TYPE
# # INTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
A3ROOM NAME
B101a
REF SHEET
NUMBER
REF SHEET NUMBER
EARTH
GRAVEL
CONCRETE
CONCRETE MASONRY UNITS
SOLID CONCRETE
MASONRY UNITS
BRICK
WOOD-FINISHED
WOOD ROUGH
PLYWOOD
GYPSUM BOARD
ACOUSTIC TILE
STEEL - LARGE SCALE
ALL METALS - SMALL SCALE
GLASS - LARGE SCALE
BATT INSULATION
RIGID INSULATION
CERAMIC TILE
CARPET
Above finished floor AFF Acoustic ACST Acoustic Panel Ceiling APC Addendum ADD Alternate ALT Aluminum AL Angle L Approximate APPROX Architecture, ARCH architectural Asbestos ASB Asphalt ASPH Assistant ASST Association ASSN Automatic AUTO Average AVG Base plate BP Basement BSMT Beam BM Bearing BRG Bedroom BR Benchmark BM Board BD Boiler BLR Bottom BOT Brick BRK Building line BL Building BLDG Built-up-roof BUR Cabinet CAB Carpet CPT Catalog CAT Ceiling height CH Ceiling CLG Center CTR Centerline CL Ceramic Tile CT Ceramic CER Chalkboard CB Clear CLR Closet CLO Coated CTD Cold rolled CR Column COL Company CO Composition COMP Concrete Masonry Unit CMU Concrete CONC Construction joint CJ Construction CONSTR "Continue, Continuous" CONT Corridor CORR Countersink CSK Cubic CU Curve(d) CRV Dampproofing DP Degree DEG Department(al) DEPT Detail DET Diagonal DIAG Diameter DIA Dimension DIM Dishwasher DW Dispenser DISP Door DR Double DBL Double-hung DH Down DN Downspout DS Drain DR Drawing DWG Each EA East E Electric Water Cooler EWC "Electric, electrical" ELEC Elevation EL Elevator ELEV Engineer ENGR Entrance ENTR
Maximum MAX Mechanical MECH Membrane MEMB Men M Metal MET, MTL Mezzanine MEZZ Minimum MIN Mirror MIR Miscellaneous MISC Mounted MTD Mounting MTG Necessary NEC Noise-reduction NRC coefficient Nominal NOM Non Combustible NC, NONCOM North N Not in Contract NIC Not to scale NTS Not available NA Number NO Office OFF On center OC Opening OPNG Opposite OPP Outside diameter OD Overall OA Overhead OVHD Page P Painted PTD Pair PR Panel PNL Partition PTN Percent PCT Perforate(d) PERF Permanent PERM Perpendicular PERP Piece PC Plastic Laminate PLAM Plastic Laminate PLAS.LAM Plate PL Plumbing PLMB Plywood PLYWD Point PT Polyvinyl chloride PVC Precast PRCST Prefabricated PREFAB Preliminary PRELIM Preparation, prepare PREP Program PRGM Projection Screen PS Project PROJ Property PROP Public Address PA Quality control QC Quality QUAL Quantity QTY Quarry Tile QT Radius RAD Rain Leader RL Received RCVD Receptacle RCPT Receptionist RECPT Recess(ed) REC Refer, reference REF Refrigerate, refrigerator REFR Reinforce REINF Reinforced concrete RC Remove RMV Repair RPR Required REQD Revise, revision REV Right hand RH Road RD Roof Drain RD Roof RF Roofing RFG Room RM Rubber tile floor RTF
Rubber RBR Schedule SCHED Schematic SCHEM Section SECT Service SVCE "Sheet, sheeting" SHT Shower SH Siding SDG Similar SIM Slope SL Sound-transmission STC class South S Speaker SPKR Specification SPEC Sprinkler SPR Square SQ Stainless steel SS Standard STD Standpipe SP Steel STL Storage STOR Structural Glazed SGFT Facing Tile Structural, structure STRUCT Substitute SUBST Surface SURF Suspend(ed) SUSP Switch SW Symmetrical SYM System SYS Tackboard TB Tackstrip TS Telephone TEL Television TV Temporary TEMP Terrazzo TER Thick THK Through THRU Toilet T Tongue and groove T&G Top and bottom T&B Top chord TC Top of Masonry Parapet TMP Top of Bearing TOFB Top of Steel T.O.S.
Topping TOPG Total TOT Transformer XFMR Transom TR Transparent TRANS Tread TRD Threshold THRESH Typical TYP Underground UG Underwriters UL Laboratories Unfinished UNF Unit Ventilator UV Unless Otherwise Noted UON Urinal UR US Gypsum Company USG Verify in Field VIF Vertical VERT Vestibule VEST, V Vinyl Reducing Strip VRS Vinyl Composite Tile VCT Vinyl asbestos tile VAT Wardrobe WARD Water closet WC Waterproof WP Weight WT Welded WLD Welded Wire Mesh WWM With W/ Without W/O Women W Wood WD Wrought Iron WI
Equal EQ Equipment EQUIP Exhaust EXH Existing EXIST Existing to Remain ETR Expansion joint EXP JT Exposed EXP Exterior EXT Fabricate FAB Face of Stud F. OF S.
Fan Coil Unit FCU Fiberglass-reinforced FRP plastics Finish FIN Finished Floor FF Fire Extinguisher FE Fire Extinguisher & FEC Cabinet Fire Retardant Treated FRT Fireproof FPRF Fixture FXTR Flange FLG Flashing FL Floor FL Floor drain FD Flooring FLG Fluorescent FLUOR Footing FTG Foundation FDN Furnish(ed), furniture FURN Furring FURR Gage (gauge) GA Galvanize(d) GALV Galvanized Iron GALVI Glazed Wall Tile GWT Grab Bar GB Grade GR Gravel GVL Gypsum Wallboard GWB Gypsum GYP Handicapped HC Hardware HDW Heating ventilating and HVAC air conditioning Height HGT High Point HPT High Performance HP High Performance HPC Coating Hollow Metal HM Horizontal HORIZ Include(d), inclusive INCL Incorporated INC Information INFO Inside diameter ID Install(ed), installation INSTL Insulation INSUL Interior INT Janitor JAN Joint JT Joist J, JST Junction box JB Knock down KD Laboratory LAB Lavatory LAV Left Hand LH Left L Length LG Level LVL Light LT Machine MACH Maintenance MAINT Manager MGR Manual MNL Manufacturing MFG Markerboard MB Masonry opening MO Masonry MSNRY Master bedroom MBR Material MATL
NOT IN SCOPE
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
TS
TI
TL
E S
H E
E T
RC
C
-W
AR
SA
W
C
AM
PU
S
W
IN
DO
W
R
EP
LA
CE
ME
NT
C am pu s D r, W ars aw
, V irg ini a
02/24/2025
BID SET
GP #22006.24
LIST OF DRAWINGS
TS TITLE SHEET
ARCHITECTURAL
A002 OVERALL FIRST FLOOR PLAN
A003 OVERALL FIRST FLOOR PLAN - ANNEX
D101 OVERALL FIRST FLOOR DEMOLITION PLAN
D102 OVERALL FIRST FLOOR DEMOLITION PLAN - ANNEX
A101 PARTIAL FLOOR PLAN
A102 PARTIAL FLOOR PLAN
A103 PARTIAL FLOOR PLAN
A201 BUILDING ELEVATIONS
A202 BUILDING ELEVATIONS - ANNEX
A305 FRAME ELEVATIONS
DRAWING KEY
SYMBOLS OF MATERIALS
ABBREVIATIONS
1/16" = 1'-0"TSA201
A12 CODE STUDY PLAN - FIRST FLOOR
PROJECT NAME AND LOCATION
NAME RAPPAHANNOCK COMMUNITY COLLEGE - WINDOW REPLACEMENT
STREET ADDRESS 52 CAMPUS DRIVE
COUNTY RICHMOND COUNTY
CITY, STATE WARSAW, VA
PROJECT DESCRIPTION: WINDOW REPLACEMENT ON AN EXISTING BUILDING AT RCC.
THERE IS NO WORK INSIDE THE BUILDING - NO CHANGE IN OCCUPANCY OR OCCUPANTS
APPLICABLE CODES
BUILDING CODE 2021 Part 2, VIRGINIA EXISTING BUILDING CODE (VEBC), Level 1
2021 VIRGINIA CONSTRUCTION CODE (VCC)
2024 VIRGINIA CONSTRUCTION & PROFESSIONAL SERVICES MANUAL (CPSM)
ACCESSIBILITY ADA90-TITLE II,Scoping Requirements of the Department of Justice’s 2010 ADA Standards for Accessible Design, dated September 15, 2010 and technical design are Chapters 1 and 3 thru 11 of Standards for Accessible and Usable Buildings and Facilities (ICC A117.1-2017) approved March 28, 2017
BUILDING USE AND CONSTRUCTION CLASSIFICATION
VCC
USE GROUP: B, BUSINESS 304.1
BUILDING AREA (PER VCC): 55,158 SF (92,000 SF ALLOWABLE)
PROPOSED CONSTRUCTION TYPE TYPE IIB (EXISTING)
ALLOWABLE BUILDING HEIGHT/STORIES: 75' (VCC TABLE 504.3), 3 STORIES (VCC TABLE 504.4)
ACTUAL BUILDING HEIGHT/STORIES: 20' MAXIMUM, 1 STORY
BUILDING VOLUME: 1,103,160 CUBIC FEET (EXISTING)
APPLICABLE CODES AND TABULATIONS
VICINITY MAP LOCATION MAP
DEB PROJECT CODE 260-B4260-073
D E S I G N T E A M
RCC - WARSAW CAMPUS
WINDOW REPLACEMENT
BID SET 02/24/2025
52 Campus Dr, Warsaw, Virginia
EXISTING CLASSROOM
BUILDING
RICHMOND ROAD
H W
Y
LEAD DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED
TO THE EXTENT POSSIBLE.
HIGH PERFORMANCE BUILDNG ACT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE
BECAUSE THE RENOVATED BUILDING AREA IS NOT GREATER THAN 5,000 GROSS SQUARE FEET.
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE AREA INDICATED. THE ASBESTOS INSPECTION REPORT IS INCLUDED IN SECTION 02 80 00 IN THE PROJECT SPECIFICATIONS. THE OWNER SHALL SUBMIT AN APPLICATION FOR PERMIT TO HAVE THE ASBESTOS-CONTAINING MATERIALS ABATED BY A LICENSED ASBESTOS CONTRACTOR UNDER A SEPARATE CONTRACT USING APPROVED PROCEDURES PRIOR TO ISSUING A NOTICE TO PROCEED TO THE GENERAL CONTRACTOR. ANY ACM THAT IS TO REMAIN AND THE NEW NON ASBESTOS-CONTAINING MATERIAL SHALL BE LABELED ACCORDINGLY. THE ASBESTOS ABATEMENT CONTRACTOR SHALL MARK UP THE AS-BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE ASBESTOS WAS ABATED, AREAS WHERE ASBESTOS WAS ENCAPSULATED, AND AREAS WHERE ACM EXIST BUT WERE LEFT IN PLACE. THE GENERAL CONTRACTOR SHALL REVIEW AND CERTIFY THE LOCATIONS WHERE ACM WAS ABATED, AREAS WHERE ACM WAS ENCAPSULATED AND AREAS WHERE ACM WAS LEFT IN PLACE AS MARKED ON THE AS-BUILT
DRAWINGS AND WILL PROVIDE THE DRAWINGS TO THE ARCHITECT.
DATE DESCRIPTION
VIRGINIA COMMUNITY COLLEGE SYSTEM
300 Arboretum Place, Suite 200 Richmond, Virginia 23236
OWNER ARCHITECT
X. TONG WANG, RA
Capital Outlay Program Manager twang@vccs.edu Tel: (804) 819-4919
RAPPAHANNOCK COMMUNITY COLLEGE
Glenns Campus 12745 College Drive, Glenns, Virginia
COLLEGE
CHERYL BOLTZ
Facilities Manager, Warsaw Campus cboltz@rappahannock.edu Tel: (804) 333-6840
GRIMM + PARKER ARCHITECTS
123 East Main St, Second Floor Charlottesville, Virginia 22902
Annette McDaniels AIA, CCCA, LEED AP BD+C Associate Principal amcdaniels@gparch.com Tel: (434) 270-0141
EXISTING ANNEX
BUILDING
GENERAL NOTES
OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND
BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS
ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS
OTHERWISE NOTED.
2. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY
ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. NO DRAWING SHALL HAVE
PRECEDENCE ONE OVER THE OTHER. IN THE EVENT OF A CONFLICT IN THE DOCUMENTS,
THE CONTRACTOR SHALL SEEK THE INTERPRETATION OF THE ARCHITECT. THE
CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL SUCH INTERPRETATION IS
OBTAINED. IF THE CONTRACTOR PROCEEDS WITHOUT CLARIFICATION, THE CONTRACTOR
WILL BE RESPONSIBLE TO REMOVE AND REPLACE ANY WORK NOT CONFORMANCE WITH
THE ARCHITECT'S DIRECTION WITHOUT ADDITIONAL COST TO THE OWNER. IN THE EVENT
OF A CONFLICT IN THE DRAWINGS OR SPECIFICATIONS, BIDDERS SHALL SEEK
CLARIFICATION FROM THE ARCHITECT. RESOLUTIONS TO SUCH CONFLICTS WILL BE
ISSUED THROUGH ADDENDA TO THE BID DOCUMENTS. IF CLARIFICATION FROM THE
ARCHITECT IS NOT RECEIVED THROUGH AN ADDENDUM PRIOR TO THE RECEIPT OF BIDS,
THE BIDDER SHALL ASSUME THE MORE COSTLY REQUIREMENT APPLIES, AND THE
AWARDED CONTRACTOR SHALL SEEK CLARIFICATION FROM THE ARCHITECT PRIOR TO THE
EXECUTION OF THE WORK.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE
ARCHITECT FOR CLARIFICATION.
4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER
MEASUREMENT, CONSULT THE ARCHITECT FOR CLARIFICATION.
5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS
OF SIMILAR USE ELSEWHERE IN THE BUILDING,
6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE
REFERENCED AS WELL AS ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR
SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN.
THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY
SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE
ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE
CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS,
WINDOWS, LOUVERS, GRILLES, MECHANICAL WORK, ETC. TO FIT TIGHT AND BE
THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED
OR OTHERWISE WATERPROOF SEALED.
9. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF
WINDOWS, AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION.
PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A
COMPLETE INSTALLATION.
10. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK
PERTAINING TO THEIR PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE
WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS.
REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
11. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED /
TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE
FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE
PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER
FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON
THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST
SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR
PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER
OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST
NEVERTHELESS INCLUDE THE ITEM IN QUESTION IN THEIR BID, CONSIDERING IT THE SAME
AS THE TAGGED SYMBOL MOST NEARLY RESEMBLING THE UNTAGGED SYMBOL BASED ON
ITS SHAPE, SIZE, LINEWEIGHT(S), LOCATION, AND SCHEDULED USAGE IN SPACES OF
SIMILAR FUNCTION. THE CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE
ARCHITECT PRIOR TO PROCEEDING WITH SHOP DRAWINGS.
KEY PLAN
AREA A AREA B
AREA C
G8 A201
L13 A201
E9 A201
J13 A201
WAITING
OFFICE
113A
OFFICE
113B
OFFICE
113C
OFFICE
182B
CONFERENCE
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
NEW STOREFRONT SYSTEM
Room
121B
Room
121C
Room
121A
Room
121D
Room
Room
Room
141A
Room
Room
141B
Room
141C
Room
Room
Room
Room
Room
Room
Room
152A
Room
Room
Room
Room
Room
Room
A R
E A
A A
R E
A B
NEW STOREFRONT SYSTEM
A R
E A
A A
R E
A B
AREA C
AREA A
AREA C
AREA A
Room
CORRIDOR
LOBBY
100BRoom
Room
100A
Room
Room
Room
Room
117J
Room
117H
Room
117C
Room
117B
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M w w w .g ri m m a n d p a rk e r.
c o m
E a s t
M a in
S tr e e t n d F lo o r
C h a rl o tt e s v ill e
V A l:
-2
-5
DEB #
260-B4260-073
A002
O V
E R
A
LL
F
IR
S T
FL
O
O R
P
LA
N
RC
C
-W
AR
SA
W
C
AM
PU
S
W
IN
DO
W
R
EP
LA
CE
ME
NT
C am pu s D r, W ars aw
, V irg ini a
02/24/2025
BID SET
GP #22006.24
1/16" = 1'-0"A002A201
C16 OVERALL FIRST FLOOR PLAN
GENERAL NOTES
OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND
BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS
ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS
OTHERWISE NOTED.
2. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY
ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. NO DRAWING SHALL HAVE
PRECEDENCE ONE OVER THE OTHER. IN THE EVENT OF A CONFLICT IN THE DOCUMENTS,
THE CONTRACTOR SHALL SEEK THE INTERPRETATION OF THE ARCHITECT. THE
CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL SUCH INTERPRETATION IS
OBTAINED. IF THE CONTRACTOR PROCEEDS WITHOUT CLARIFICATION, THE CONTRACTOR
WILL BE RESPONSIBLE TO REMOVE AND REPLACE ANY WORK NOT CONFORMANCE WITH
THE ARCHITECT'S DIRECTION WITHOUT ADDITIONAL COST TO THE OWNER. IN THE EVENT
OF A CONFLICT IN THE DRAWINGS OR SPECIFICATIONS, BIDDERS SHALL SEEK
CLARIFICATION FROM THE ARCHITECT. RESOLUTIONS TO SUCH CONFLICTS WILL BE
ISSUED THROUGH ADDENDA TO THE BID DOCUMENTS. IF CLARIFICATION FROM THE
ARCHITECT IS NOT RECEIVED THROUGH AN ADDENDUM PRIOR TO THE RECEIPT OF BIDS,
THE BIDDER SHALL ASSUME THE MORE COSTLY REQUIREMENT APPLIES, AND THE
AWARDED CONTRACTOR SHALL SEEK CLARIFICATION FROM THE ARCHITECT PRIOR TO THE
EXECUTION OF THE WORK.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE
ARCHITECT FOR CLARIFICATION.
4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER
MEASUREMENT, CONSULT THE ARCHITECT FOR CLARIFICATION.
5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS
OF SIMILAR USE ELSEWHERE IN THE BUILDING,
6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE
REFERENCED AS WELL AS ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR
SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN.
THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY
SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE
ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE
CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS,
WINDOWS, LOUVERS, GRILLES, MECHANICAL WORK, ETC. TO FIT TIGHT AND BE
THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED
OR OTHERWISE WATERPROOF SEALED.
9. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF
WINDOWS, AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION.
PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A
COMPLETE INSTALLATION.
10. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK
PERTAINING TO THEIR PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE
WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS.
REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
11. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED /
TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE
FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE
PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER
FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON
THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST
SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR
PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER
OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST
NEVERTHELESS INCLUDE THE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .