R05_Strip_and_replace_roof._733_Edgewood.docx

DOCX document 34 KB Posted

Attached to
733 EDGEWOOD ST - ROOF HOME & GARAGE, GUTTERS (HOME ONLY)
Solicitation number
2025-COMMUNITY DEVELOPMENT-009
Issued by
Kalamazoo County, Huntington Woods City, Michigan

About this file

This is a Work Write-Up document prepared by the City of Jackson, Michigan for a residential roof and gutter replacement project located at 733 Edgewood Street in Jackson, Michigan. The project involves stripping and replacing the roof on both the home and garage, totaling approximately 28 squares (2,800 square feet), and installing new gutters on the home spanning approximately 280 linear feet. The work requires a permit and includes comprehensive roofing specifications such as installing oriented-strand board sheathing, ice shields, asphalt felt, architectural-style roofing materials, metal edging, valley treatments, reflashing, and proper ventilation. The project will use architectural shingles, with specific areas requiring rubber or modified roofing materials due to shallow pitch.

The contract opportunity is being managed through the City of Jackson's e-Procurement Portal, with sealed proposals to be submitted to Purchasing Coordinator Kari Kerstetter. No pre-bid meeting is scheduled, but contractors may contact the homeowner to assess the property. The project adheres to various civil rights regulations and non-discrimination standards, with the City of Jackson committed to equal employment opportunity across its programs and activities. Specific technical requirements include using pre-enameled aluminum gutters, maintaining proper pitch and drainage, and ensuring all materials and installations meet local building codes and manufacturer specifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Work Write-Up R05 Strip and replace roof.

* EXHIBIT 1 *

Dated: 10/25/2024

CUSTOMER INFORMATION

Alyssa Griwatsch 733 Edgewood St., Jackson, MI 49202

PREPARED BY

sharrison@cityofjackson.org

* NOTE *

THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF

1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT

2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP

Location: Unassigned

General Requirements
Quantity
Units
Total

1 - R05 - ROOF - STRIP AND INSTALL Garage (Specification ID:1.05000 Estimated Qty:8)

SF

* PERMIT REQUIRED *

Strip existing roof, removing all shingles and felt. Make repairs to the existing roof framing where required to provide adequate strength and a true and level surface. Install 7/16” oriented-strand board sheathing to cover all areas of roof deck. Just before proceeding, sweep roof thoroughly to remove all debris. Install ice shield at all lower roof edges. Ice shield shall extend at least 24" inside the interior surface of the exterior wall line of the building, in accordance with the Michigan Building Code. Install new 15% asphalt saturated felt according to manufacturer's directions. Furnish and install new roofing material of a color as selected by owner, must be architectural style. Installation shall include metal drip and rake edge, two layers of 90# roll valley or metal valley in all valleys. Reflash chimney, plumbing vents, and vertical walls with appropriate neoprene boots and metal step flashing where possible. Install ventilation units sufficient to vent all areas of attic. Ridge venting when used shall cover the full length of the roof ridge. Installation of all materials shall follow manufacturer's printed instructions and G.S. 1.

Contractor is responsible for final measurement.

Approximately __________ squares on__________ New roofing material type shall be__________ Manufacturer: __________ Color Name/Number: __________ Contractor's Initials: ____________________ Owner's Initials: __________ Rehab Initials________

2 - R05 - ROOF - STRIP AND INSTALL Home (Specification ID:1.05000 Estimated Qty:20)

Sq

* PERMIT REQUIRED *

Strip existing roof, removing all shingles and felt. Make repairs to the existing roof framing where required to provide adequate strength and a true and level surface. Install 7/16” oriented-strand board sheathing to cover all areas of roof deck. Just before proceeding, sweep roof thoroughly to remove all debris. Install ice shield at all lower roof edges. Ice shield shall extend at least 24" inside the interior surface of the exterior wall line of the building, in accordance with the Michigan Building Code. Install new 15% asphalt saturated felt according to manufacturer's directions. Furnish and install new roofing material of a color as selected by owner, must be architectural style. Installation shall include metal drip and rake edge, two layers of 90# roll valley or metal valley in all valleys. Reflash chimney, plumbing vents, and vertical walls with appropriate neoprene boots and metal step flashing where possible. Install ventilation units sufficient to vent all areas of attic. Ridge venting when used shall cover the full length of the roof ridge. Installation of all materials shall follow manufacturer's printed instructions and G.S. 1.

Contractor is responsible for final measurement.

Note: The two areas that are very shallow pitched, these shall be done in a rubber roofing materials or a modified material. To include that the chimney is in sound condition for flashing, around the roof line area.

Approximately __________ squares on__________ New roofing material type shall be__________ Manufacturer: __________ Color Name/Number: __________ Contractor's Initials: ____________________ Owner's Initials: __________ Rehab Initials________________

3 - G08 - GUTTERWORK Home Only (Specification ID:1.08000 Estimated Qty:280)

LF

Furnish and install gutter and downspout. Replacements shall match existing as to materials, finish, shape and size. Do not mix galvanized with copper or aluminum. Where replacements are of a complete system or side of a system having no cross connections with sections not to be replaced, used baked pre-enameled aluminum, 5-inch K-type in standard colors. Minimum thickness of aluminum shall be .027 inches for troughs and fittings. Use one or a combination of strap hangers, spike and ferrules or fascia hangers. Space hangers and slip joint connectors per manufacturer's instructions. Maximum spacing of hangers shall be 48 inches OC for galvanized and 30 inches for aluminum. Use only recommended gutter seal and rivets or screws at all joints. All work, whether a complete new system or a partial replacement, shall have the system with a pitch of not less than 1 inch in 16 feet. Divert the water away from the foundation using appropriate extensions and/or concrete splash blocks. All work to conform to code and G.S. 4a.

Contractor responsible for final measurements.

All downspouts shall be commercial size.

Approximately 200 linear feet of gutter on all elevation(s).

Approximately 100 linear feet of downspout on all elevation(sn) .

Subtotal for General Requirements

Total

Prepared By: sharrison@cityofjackson.org on 10/25/2024

OWNER ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.

x___________________________________
Owner:Date

CONTRACTOR ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.

x___________________________________
ContractorDate
x______________________________________
Construction SpecialistDate
Prepared By: sharrison@cityofjackson.org on 10/25/2024